Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A18-0061_Approved Documents_1539644038.pdf
75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspections: inspections@vailgov.com Fire - Construction Permit A18-0061 Issued: 10/15/2018 TOWN OF VAIL Property Information Address: 250 VAIL LN (210108286003) ( 210108286003 ) Unit #: Parcel Number: 210108286003 Legal Description: Subdivision: FRONT DOOR LODGE AND RESORT Tract: A Contacts Contact Type: Applicant Full Name: Daniel Dimitrov Address: P.O. Box 4631 60 Mill Rd. M2 Eagle, CO 81631 Phone: 9706880621 Contact Type: Property Owner Full Name: CHALETS AT THE LODGE AT VAIL LLC VAIL RESORTS DEVELOPMENT COMPANY Address: Phone: None Contractor Contractor Type: Alarm Company: Dimant Technologies LLC State License #: Phone: 970-688-0672 Project Information Project Name: Vail Mtn Club Elevator Alarm 2018 Project Description: Vail Mtn Club - Install a power supervision module for the shunt power for the new elevator. Fees Paid Account #: 001-0000.31111.00 - Fire Scope Letter Fee Fee Amount:$216.00 Total Paid:$216.00 Conditions Issued By: Town of Vail Fire and Emergency Services Department NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. PERMIT FEE RECEIPT Case # A18-0061 Date Printed: 10/12/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: A18-0061 Status: Created Permit Number: Date Started: 10/11/2018 Permit Type: Fire - Construction Permit Subcases Fire Alarm Lot Number: Tract A Property: 250 VAIL LN (210108286003) (210108286003) Contacts Contact Type: Applicant Company Name: Dimant Technologies LLC Full Name: Daniel Dimitrov Address: P.O. Box 4631 60 Mill Rd. M2 Eagle, CO 81631 Email: dimitrov.dimant@gmail.com Contact Type: Property Owner Full Name: CHALETS AT THE LODGE AT VAIL LLC VAIL RESORTS DEVELOPMENT COMPANY Address: Permit Fees Fee Information Account Amount Fire Scope Letter Fee 001-0000.31111.00 $216.00 Payment Information Date Paid Payment Type Amount Fire Scope Letter Fee 10/12/2018 Credit Card $216.00 Paid By: - Notes: Visa - Daniel Dimitrov FEE TOTAL $216.00 AMOUNT PAID $216.00 BALANCE DUE $0.00 10/12/2018 - 3:07:49 PM - Generated by: dcouch75 South Frontage Road West, Vail, Colorado 81657 1 / 1 Features IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from IAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use in indoor locations up to 158° F (70° C) such as attic spaces or similar applications For use with following Simplex control panels: Model Series 4007ES, 4008, 4010, 4010ES, and 4100ES fire alarm control panels for IDNet communications Model Series 4100/4100U/4100ES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterflow switch (alarm) on same circuit using one point Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use City of New York Department of Buildings MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products . - IDNET IN ++IDNET IN - 4090-9001 Supervised IAM (shown approximately 3/4 size) LISTED SIGNALING DEVICEISSUE NO. 4090-9051 Supervised IAM (shown approximately 3/4 size) Description Individual addressable modules (IAMs) receive both power and communications from a two-wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is an encapsulated package with wire leads. It does not provide a status indicating LED. Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNet and MAPNET II Communicating Devices, MEA (NYC) Acceptance* Individual Addressable Modules (IAMs) S4090-0001-12 8/2016 Operation Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). Current Limited Operation Applications For use with IDNet communications only, these IAMs can provide quad-state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is T-sense.) With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterflow switch monitoring can be determined and communicated by a single addressable point. Model Description 4090-9001 Supervised IAM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 Supervised IAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, includes mounting screws; galvanized steel4090-9807 For surface mounted box 4090-9810 Mounting bracket, mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. Description 4081-9004 733-886 6.8 k, 1/2 W; Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 733-896 4.7 k, 1/2 W Use for current limited monitoring applications4081-9005 733-984 1.8 k, 1/2 W Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per IAM Input Requirements Normally open, dry contacts Wire Connections 4090-9001 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) 4090-9051 Color coded wire leads, 18 AWG (0.82 mm2), 8 long (203 mm) Reference Documents Installation Instructions 574-331 for 4090-9001; 579-572 for 4090-9051 Field Wiring Diagrams 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from IAM to Contacts 500 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or IDNet Communications 2500 ft (762 m) maximum from fire alarm control panel 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical Dimensions 4090-9001 1-9/16 W x 1-3/4 H x 1-1/4 D (40 mm x 44 mm x 32 mm) 4090-9051 1-9/16 W x 1-9/16 H x 9/16 D (40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 158° F (0° to 70° C); intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) 2 S4090-0001-12 8/2016 IAM Product Selection Specifications Optional Trim Plates and Mounting Bracket for Visible LED Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) 4090-9001 IDNet supervised IAM Field wiring shown for reference Address setting under resealable label - IDNET IN ++IDNET IN - LED viewing port 4090-9806, Trim plate for semi-flush mounted box 4090-9807, Trim plate for surface mounted box 4-1/4" (108 mm) 2-1/2" (64 mm) 2-13/16" (72 mm) 4-1/2" (114 mm) Light pipe for LED viewing NOTE: These mounting plates require mounting bracket 4090-9810. 4090-9810 Mounting bracket, ordered separately Mounting Reference, Single Gang Blank Cover Plate 2 S4090-0001-12 8/2016 Mounting Information Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws (supplied by others) 4090-9051 Encapsulated Supervised IAM Address setting is at rear of housing LISTED SIGNALING DEVICEISSUE NO. Tyco Fire Protection Products Westminster, MA 01441-0001 USA S4090-0001-12 8/2016 www.simplex-fire.com © 2016 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. 4090-9051 Mounting Information Mechanically Installing the Supervised IAM Install the Supervised IAM into a UL Listed single-gang, 4-inch square, or 4-inch octagonal electrical box (not supplied) using Figure 4 as a reference. Mount the Supervised IAM to the electrical box as follows: 1. Insert the Supervised IAM into the electrical box; the attached field wiring holds the Supervised IAM in place inside the electrical box. 2. Secure the cover to the back box using the two #6/32 flathead screws. Note: Simplex offers semi-flush and surface covers (ordered separately) with a light pipe. The cover(s) with light pipe allow viewing of the communications LED without taking the cover off. Installation of the 4090-9806 semi-flush cover and 4090-9807 surface cover are detailed in publication 4090 IDNet Semi-Flush/Surface Covers and IAM Bracket Installation Instruction (574-796). Figure 4. Supervised IAM Back Box Installation 4090-9001 Supervised IAM Installation Instructions 574-331 Rev. G 574-331 Rev. G 2000, 2010, 2012 Tyco Fire Protection Products. All rights reserved. Specifications and other information shown were current as of publication, and are subject to change without notice. TYCO, SIMPLEX, IDNet, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. UL Listed Single-Gang Electrical Box (Not Supplied) Cover (Not Supplied) Field Wiring 4090-9001 Supervised IAM Assembly #6/32 Flathead Screw (Not Supplied) Cautions and Warnings DO NOT INSTALL ANY SIMPLEX® PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately file a claim with the carrier and notify an authorized Simplex product supplier. ELECTRICAL HAZARD - Disconnect electrical field power when making any internal adjustments or repairs. All repairs should be performed by a representative or authorized agent of your local Simplex product supplier. STATIC HAZARD - Static electricity can damage components. Ground yourself before opening or installing components. TEMPERATURE RANGE - 32° to 158°F (0° to 70°C) Introduction IDNet The 4090-9001 Supervised Individual Addressable Module (IAM) provide four-state status information (NORMAL, OPEN, CURRENT-LIMITED, and SHORT) to the 4008, 4010, 4010ES, 4100U, and 4100ES Fire Alarm Control Panel (FACP) via the IDNet channel. The IDNet channel provides the communication link between Supervised IAM and the FACP and powers the entire IAM circuitry. A typical application for this module would be to monitor a waterflow switch. MAPNET II The 4090-9001 Supervised IAM provides three-state status information (NORMAL, OPEN, and ALARM) to the host FACP via the MAPNET II channel. Applications that require current limit sensing are not compatible with MAPNET II channels (Tamper/Waterflow on the same IAM, Manual release/abort, etc.). The MAPNET II channel provides the communication link between the Supervised IAM and host 4100, or 4120, or 4020 FACP and powers the entire IAM circuitry. Installation Supervised IAM installation consists of the following: Setting the Supervised IAMs address Making electrical connections to the Supervised IAM Mechanically installing the Supervised IAM ®¯°±² ³´µ¶ ·µ¸¯ ³´µ¶ Label DIP Switch (Under Re-sealable Label) LED Terminal Note: The LED flashes approximately once every three seconds to indicate valid communications with the FACP. Figure 1. Supervised IAM Installation Making Electrical Connections to the Supervised IAM Input and output signals connect to the Supervised IAM via the terminals (1-4) as illustrated in Figure 1. Terminal connections for the IAM are illustrated in Figure 3. CAUTION: Do not loop wire under terminals. Break wire runs to provide supervision. Notes: 1. When connecting two wires to one terminal, position one wire on each side of the terminal screw. 2. IDNet and MAPNET II lines are 18 AWG twisted pair (shield recommended). 3. Maximum allowable run from FACP to farthest device not to exceed 2500 feet. Maximum total wire (including all T-Taps) from FACP is 10000 feet. 4. Maximum wire length is 400 feet, #18 AWG. 5. Refer to Field Wiring Diagram 842-073 for further information on wiring Supervised IAMs to IDNet. Refer to Field Wiring Diagrams 841-804 or 841-996 for further information on wiring Supervised IAMs to MAPNET II. IDNet and MAPNET II wiring are supervised and power-limited. Figure 3. Supervised IAM Connections 32 Setting the Supervised IAMs Address Note: The IDNet channel (4010, 4010ES, 4100U, and 4100ES) supports address codes 1 through 250. The 4008 supports address codes 1 through 200. The MAPNET II channel (4100, or 4120, or 4020 FACP) supports address codes 1 through 127. Each Supervised IAM has a unique address. The address of the IAM is set via an eight position DIP switch (Figure 1), DIP switch position 1 is the least significant bit (LSB) and position 8 is the most significant bit (MSB). Set the IAMs address using Figure 2 as reference. Use a small screwdriver or pen to set the switches. The device address for the Supervised IAM should be written on the re-sealable label, this information provides an aid in troubleshooting the system. Note: DIP switch in “1” position is “ON” while DIP switch in “0” position is “OFF.” FigureTag FD4-331-01 0000100001001100001010100110111000011001010111010011101101111111 0000 0 16 32 48 64 80 96 112 128 144 160 176 192 208 224 240 1000 1 17 33 49 65 81 97 113 129 145 161 177 193 209 225 241 0100 2 18 34 50 66 82 98 114 130 146 162 178 194 210 226 242 1100 3 19 35 51 67 83 99 115 131 147 163 179 195 211 227 243 0010 4 20 36 52 68 84 100 116 132 148 164 180 196 212 228 244 1010 5 21 37 53 69 85 101 117 133 149 165 181 197 213 229 245 0110 6 22 38 54 70 86 102 118 134 150 166 182 198 214 230 246 1110 7 23 39 55 71 87 103 119 135 151 167 183 199 215 231 247 0001 8 24 40 56 72 88 104 120 136 152 168 184 200 216 232 248 1001 9 25 41 57 73 89 105 121 137 153 169 185 201 217 233 249 0101 10 26 42 58 74 90 106 122 138 154 170 186 202 218 234 250 1101 11 27 43 59 75 91 107 123 139 155 171 187 203 219 235 0011 12 28 44 60 76 92 108 124 140 156 172 188 204 220 236 1011 13 29 45 61 77 93 109 125 141 157 173 189 205 221 237 0111 14 30 46 62 78 94 110 126 142 158 174 190 206 222 238 15 31 47 63 79 95 111 127 143 159 175 191 207 223 239 LSB MSB 1 2 3 4 5 6 7 8 1111 DIP SWITCHES 5 THRU 8 ON OFF 1 = ON 0 = OFF 251 252 253 254 255 DIPSWITCH IS SHOWN SET AT ADDRESS 7. Figure 2. Supervised IAM Address Chart 4008 FACP (IDNet Channel) Configure the Supervised IAM to the host 4008 FACP using the 4008 Fire Alarm Installation, Programming and Operating Instructions (579-716). 4010 FACP (IDNet Channel) Configure the Supervised IAM to the 4010 panel using the 4010 Fire Alarm - Installation and Programming (574-187) and 4010 Fire Alarm - Installing, Operating, and Programming Instructions (574-052). Refer to 4010 panel label 526-444 for appropriate revision of the instructions to be used. 4100U, 4100ES, and 4010ES FACP (IDNet Channel) Configure the Supervised IAM using the ES Panel Programmer’s Manual (574-849). 4100/4120/4020 FACP (MAPNET II Channel) Configure the Supervised IAM to the host FACP using the 4100, 4120, or 4020 Programmer’s Report. The Supervised IAM address and location must match up with the address listed in the specification sheets of the 4100, 4120, or 4020 Programmer’s Report. Note: Refer to the FACP label for appropriate revision of instructions. MAPNET II supports address codes 1 through 127 only. MAPNET II/IDNET (See Notes) MAPNET II/IDNET To Next Device (See Note 5) See Note 4 EOL Resistor Harness 4081-9004 733-886 Project: Vail Mountain Club Elevator Upgrade Address: 250 Vail Road, Vail, CO 81657 Fire alarm contractor: Dimant Technologies LLC WIRE TYPE INFORMATION SLV – 16 AWG / 2 Conductors FPLP twisted pair. Daniel Dimitrov NICET Fire alarms Level III Cert.# 119879 Digitally signed by Daniel Dimitrov DN: cn=Daniel Dimitrov, o=DimantTechnologies LLC, ou, email=dimitrov.dimant@gmail.com, c=US Date: 2018.10.11 17:23:46 -06'00'