Loading...
HomeMy WebLinkAboutB14-0277_CCK! Asbestos Report_1407170280 (2).pdf1675 North Commerce Parkway, Weston, Florida 33326 Tel: (954) 384-4446 Fax: (954) 384-4838 CERTIFICATE OF BULK ASBESTOS ANALYSIS Prepared for: Phone Number: Fax Number: Email Address: Test Location: Report Number: Date Sampled: Date Analyzed: Report Date: __________________________________________________ __________________________________________________ Andrew Pittman, QA/QC Manager Analytical results and reports generated by PRO-LAB/SSPTM, Inc. are generated for and at the request of its client(s) named on this report, and for their exclusive use. PRO-LAB/SSPTM, Inc. does not release original, copies or verbal results to any third party without prior written approval from the named client(s). This report applies only to the sample(s) tested. This report must not be reproduced, except in full, without written approval from PRO-LAB/SSPTM, Inc. The client(s) is solely responsible for the use and interpretation of test results and reports requested from PRO-LAB/SSPTM, Inc. This report must not be used by the client to claim product endorsement by NVLAP, NIST or any other agency of the U.S. Government. PRO-LAB/SSPTM, Inc. is not able to assess the degree of hazard resulting from materials analyzed. PRO-LAB/SSPTM, Inc. reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise requested. Asbestos samples from New York are analyzed by Environmental Hazards Services, LLC, NY ELAP #11714. If you have questions or comments, please contact PRO-LAB at (954) 384-4446 rev 1.4 MATT HANSEN PO BOX 2354 VAIL, CO 81658 MATT HANSEN (970) 401-1100 matt@ecedesignbuild.com MATT HANSEN 2480 CHAMONIX LN KI VAIL, CO 81658 062614-0037 Jun 20, 2014 Jul 3, 2014 Jul 3, 2014 Page 1 of 3 Andrew Pittman, PLM Analyst Andrew Pittman, QA/QC Manager BULK ASBESTOS ANALYSIS All percentages are visually estimated by volume ASBESTOS FIBERS NON-ASBESTOS FIBERS NON-FIBROUS MATERIALS OTHERS COMMENTS: Chrysotile: Amosite: Crocidolite: Anthophyllite: Tremolite: Actinolite: Synthetics: Mineral Wool: Fiberglass: Cellulose: Animal Hair: Antigorite: Vermiculite: Biotite: Mica: Perlite: Aggregates: Styrofoam: Aluminum: Bitumen: Resilient Material: Glue: Binders: Note: Limit of Quantification (LOQ) = 1%. 'Trace' indicates the presence of asbestos below the LOQ. 'ND'=None Detected. The EPA requirement for analyzing and reporting asbestos is as follows: A substance that contains less than 1% is not considered to have asbestos even though this may still contain traces of asbestos (just less than 1%). For further information please visit the EPA website at www.epa.gov/iaq/asbestos.html. All analyses are performed in accordance with the EPA 600/M4-82-020 method. This report must not be reproduced except in full, without written approval from PRO-LAB/SSPTM, Inc. These test results apply only to the samples actually tested. Floor tile is non-homogeneous and results reflect sample content. All samples will be stored for a period of thirty (30) days. The refractive index was determined by using `Rapidly and Accurately Determining Refractive Indices of Asbestos Fibers by Using Dispersion Staining Method`, by S-C. Su. The information contained in this report and any attachments is confidential information intended only for the use of the individual or entities named above. This report must not be used by the client to claim product endorsement by NVLAP, NIST or any other agency of the U.S. Government. _____________________________________________________________________ _____________________________________________________________________ PREPARED FOR MATT HANSEN PO BOX 2354 VAIL, CO 81658 TEST LOCATION MATT HANSEN 2480 CHAMONIX LN KI VAIL, CO 81658 CHAIN OF CUSTODY #: TEST ID NUMBER: SAMPLING DATE: DATE RECEIVED: DATE ANALYZED: REPORT DATE: SAMPLE LOCATION: COLOR / DESCRIPTION: SERIAL # SAMPLE LAYER: 763642 062614-0037 Jun 20, 2014 Jun 26, 2014 Jul 3, 2014 Jul 3, 2014 WALL WHITE TEXTURE 1 <1% ND ND ND ND ND ND ND ND ND ND ND ND ND 20% ND ND ND ND ND ND ND 80% PAINT INCLUDED AS BINDERS. Page 2 of 3 Andrew Pittman, PLM Analyst Andrew Pittman, QA/QC Manager BULK ASBESTOS ANALYSIS All percentages are visually estimated by volume ASBESTOS FIBERS NON-ASBESTOS FIBERS NON-FIBROUS MATERIALS OTHERS COMMENTS: Chrysotile: Amosite: Crocidolite: Anthophyllite: Tremolite: Actinolite: Synthetics: Mineral Wool: Fiberglass: Cellulose: Animal Hair: Antigorite: Vermiculite: Biotite: Mica: Perlite: Aggregates: Styrofoam: Aluminum: Bitumen: Resilient Material: Glue: Binders: Note: Limit of Quantification (LOQ) = 1%. 'Trace' indicates the presence of asbestos below the LOQ. 'ND'=None Detected. The EPA requirement for analyzing and reporting asbestos is as follows: A substance that contains less than 1% is not considered to have asbestos even though this may still contain traces of asbestos (just less than 1%). For further information please visit the EPA website at www.epa.gov/iaq/asbestos.html. All analyses are performed in accordance with the EPA 600/M4-82-020 method. This report must not be reproduced except in full, without written approval from PRO-LAB/SSPTM, Inc. These test results apply only to the samples actually tested. Floor tile is non-homogeneous and results reflect sample content. All samples will be stored for a period of thirty (30) days. The refractive index was determined by using `Rapidly and Accurately Determining Refractive Indices of Asbestos Fibers by Using Dispersion Staining Method`, by S-C. Su. The information contained in this report and any attachments is confidential information intended only for the use of the individual or entities named above. This report must not be used by the client to claim product endorsement by NVLAP, NIST or any other agency of the U.S. Government. _____________________________________________________________________ _____________________________________________________________________ PREPARED FOR MATT HANSEN PO BOX 2354 VAIL, CO 81658 TEST LOCATION MATT HANSEN 2480 CHAMONIX LN KI VAIL, CO 81658 CHAIN OF CUSTODY #: TEST ID NUMBER: SAMPLING DATE: DATE RECEIVED: DATE ANALYZED: REPORT DATE: SAMPLE LOCATION: COLOR / DESCRIPTION: SERIAL # SAMPLE LAYER: 763642 062614-0037 Jun 20, 2014 Jun 26, 2014 Jul 3, 2014 Jul 3, 2014 WALL WHITE WALLBOARD 2 ND ND ND ND ND ND ND ND ND 30% ND ND ND ND ND ND ND ND ND ND ND ND 70% Page 3 of 3