HomeMy WebLinkAboutB18-0050_Approved Plans_1525972812.pdf05/10/18
2
1
1
3
4
4
4
4
4
4
4
5
5
5
5
1
2
1
DEMO PLAN KEYED NOTES
DEMO PLAN LEGEND
EXISTING PARTITION/ELEMENT
TO BE REMOVED
EXISTING
PARTITION/FIXTURE TO
REMAIN
EXISTING COLUMN (TO REMAIN)
EMBEDDED IN THIS WALL. USE CARE
DURING DEMOLITION
EXISTING BUILDING ELEMENT T.B.D. GC
TO CAREFULLY INSPECT AND EVALUATE
POSSIBLE REMOVAL OR RELOCATION
WITH ARCHITECT
REMOVE EXISTING CEILING GRID AND
LIGHT FIXTURES, SALVAGE TO BUILDING
OWNER
2
3
REMOVE EXISTING FLOORING THIS
AREA
4
REMOVE EXISTING CABINETRY THIS AREA5
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
SF HP
03.05.18
A100
DEMOLITION
PLAN
SCALE: 1/4"=1'-0"
DEMOLITION PLAN1
DEMOLITION GENERAL NOTES
1. ASBESTOS VERIFICATION: GENERAL CONTRACTOR TO TEST FOR ASBESTOS CONTAINING MATERIAL WHICH ARE
IMPACTED BY NEW CONSTRUCTION, SUCH AS, BUT NOT LIMITED TO, RESILIENT FLOOR TILE, INSULATION OF PIPING
AND/OR MECHANICAL EQUIPMENT AND TEXTURED CEILINGS. IF TESTED POSITIVE, PROCEED PER LOCAL AND FEDERAL
GUIDELINES OR AUTHORITIES HAVING JURISDICTION FOR ASBESTOS ABATEMENT PRIOR TO ALL OTHER DEMO OR NEW
CONSTRUCTION WORK.
2. REMOVE EXISTING DOOR HARDWARE AS NECESSARY. REUSE EXISTING CORES IF POSSIBLE.
3. REMOVE EXISTING PARTITIONS, STUDS, ELECTRICAL, TELEPHONE, DATA, SWITCHES, THERMOSTATS, TELEPHONE
MOUNTING BOARDS, WINDOWS, DOORS, FRAMES, AND MILLWORK WHERE DEMO WORK OCCURS ON PLAN.
4. REMOVE EXISTING FLOORING AND GLUE WHERE DEMO WORK OCCURS ON PLAN. REMOVE EXISTING BASE WHERE
DEMO WORK OCCURS ON PLAN. REMOVE EXISTING WALLCOVERING WHERE DEMO WORK OCCURS ON PLAN.
5. REMOVE EXISTING PLUMBING FIXTURES WHERE DEMO WORK OCCURS ON PLAN. CAP OFF PLUMBING. IN PARTITIONS
BEING REMOVED AND/OR LOCATIONS SPECIFIED, STRIP OUT ALL SOIL LINES TO BE FLUSH WITH SLAB OR BELOW SLAB
AND PROPERLY CAP AND SEAL.
6. AT PARTITIONS BEING REMOVED, STRIP OUT ALL POWER TO NEAREST J-BOX ABOVE SUSPENDED CEILING. AT J-BOX,
WIRE NUT ALL TERMINATIONS AND CLOSE BOX.
7. REMOVE EXISTING LIGHT FIXTURES, GYPSUM BOARD CEILINGS AND SOFFITS, AND ACOUSTICAL CEILING TILE AND GRID
AS NOTED ON PLAN(S).
8. CAREFULLY REMOVE AND DELIVER TO TENANT OR BUILDING OWNER ALL SALVAGEABLE ITEMS SUCH AS DOORS,
HARDWARE, PLUMBING FIXTURES, WINDOWS, LIGHT FIXTURES, CEILING TILE, THERMOSTATS, OUTLETS, SWITCHES,
WINDOW COVERINGS AND GRILLES. REUSE ITEMS IF POSSIBLE OR AS NOTED.
9. THE GENERAL CONTRACTOR SHALL PROPERLY SEAL AND SECURE ADJOINING AREAS SO THAT THEY ARE NOT IMPACTED
BY DEMOLITION. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY PROTECTION WHERE OPENINGS CREATED
AS A RESULT OF DEMOLITION EXPOSE THIS SCOPE OF WORK TO THE EXTERIOR ELEMENTS OR WEATHER.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING MATERIALS DURING DEMOLITION.
11. IF DEMOLITION OCCURS IN AREAS ADJACENT TO A COMMON ELEVATOR LOBBY OR OTHER BUILDING CORRIDOR,
LEAVE EXTRA BUILDING FLOORING, BASE, WALLCOVERING, AND CEILING IN THE AREA TO BE DEMOLISHED TO ENSURE
A CLEAR TRANSITION OF FINISHES.
12. COORDINATE WITH TENANT OR BUILDING OWNER FOR AREA TO STAGE MATERIALS FOR REUSE.
N
05/10/18
05/10/18
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
SF HP
03.05.18
A201
DOORS
AND GLAZING
DOOR/GLAZING GENERAL NOTES
GLAZING
1. IF EXISTING GLASS TO BE REUSED IS NOT TEMPERED GLASS, REPLACE WITH TEMPERED GLASS IF WINDOW IS WITHIN
24" OF A DOORWAY.
2. ALL GLAZING WITHIN 24" OF A DOORWAY SHALL BE TEMPERED.
3. TOUCH UP OR REPAINT EXISTING EXTERIOR WINDOW FRAMES, MULLIONS, AND SILLS AS NECESSARY IN AREAS OF
NEW CONSTRUCTION.
DOORS
3. ALL OF THE MATERIALS USED IN THIS PROJECT SHALL BE LOW OR NO VOLATILE ORGANIC COMPOUND (VOC), AND
LOW ODOR PRODUCTS INCLUDING BUT NOT LIMITED TO: ADHESIVES, STAINS, LATEX AND OIL BASED PAINTS, AND
CLEANING CHEMICALS.
4. PROVIDE SHOP DRAWINGS ON ALL WOOD DOORS AND FRAMES, PRIOR TO ORDERING OF MATERIAL AND
FABRICATION, FOR INTERIOR DESIGNER COMMENTS AND APPROVAL. SHOP DRAWINGS THAT ARE NOT BOTH
RECEIVED AND APPROVED BY INTERIOR DESIGNER SHALL BE UNDERSTOOD TO BE "NOT APPROVED" BY THE
INTERIOR DESIGNER.
5. PROVIDE 4 SUBMITTAL SAMPLES OF ALL DOOR AND FRAME FINISHES FOR INTERIOR DESIGNER APPROVAL, PRIOR
TO ORDERING OF MATERIAL AND FABRICATION. SAMPLES THAT ARE NOT BOTH RECEIVED AND APPROVED BY
INTERIOR DESIGNER SHALL BE UNDERSTOOD TO BE "NOT APPROVED" BY THE INTERIOR DESIGNER.
6. ALL INTERIOR DOORS TO HAVE 1/4" UNDERCUT UNLESS NOTED OTHERWISE. FIELD VERIFY ALL DOOR OPENING
HEIGHTS PRIOR TO CUTTING DOORS.
7. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR
EFFORT. MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS ARE PROHIBITED. IN GROUP "A", "B",
"F", "M", AND "S" AND CHURCH TYPE OCCUPANCIES, KEY LOCKING HARDWARE MAY BE USED ON THE MAIN
EXTERIOR EXIT DOORS IF THERE IS A VISIBLE SIGN OVER THE DOOR STATING "THESE DOORS TO REMAIN UNLOCKED
WHEN BUILDING IS OCCUPIED."
8. TOUCH UP STAIN ON ALL EXISTING WOOD DOOR FRAMES AND TRIM AS NECESSARY. REPAINT OR TOUCH UP ALL
EXISTING METAL DOORS AND FRAMES AS NECESSARY.
DOOR HARDWARE
9. NEW DOOR HARDWARE SHALL INCLUDE: PASSAGE OR LOCKSET, 1½ PAIR OF BUTTS AND DOOR STOP (EITHER
WALL MOUNTED OR FLOOR MOUNTED AS APPLICABLE). ALL HARDWARE SHALL HAVE THE SAME FINISH. GENERAL
CONTRACTOR SHALL PROVIDE IF APPLICABLE MISSING COMPONENTS LISTED ABOVE AS REQUIRED FOR NEW
CONSTRUCTION. ALL HARDWARE NEW AND/OR RELOCATED MUST BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER INSTRUCTIONS. ALL ENTRY AND EXIT DOORS SHALL HAVE A CLOSER (UNLESS NOTED OTHERWISE).
ALL DOORS SHALL HAVE A DOOR STOP AT ALL INTERIOR DOORS, FLOOR MOUNTED WHEREVER POSSIBLE AND
WALL MOUNTED WHERE NOT. DOOR STOP SHALL MATCH SPECIFIED HARDWARE.
10. ALL NEW AND RELOCATED DOORS SHALL HAVE LEVER HARDWARE (UNLESS NOTED OTHERWISE) IN ORDER TO
CONFORM TO CURRENT ADA AND HANDICAPPED REQUIREMENTS. IF HARDWARE MUST BE CHANGED OUT, USE
EXISTING CORES IF POSSIBLE.
11. COORDINATE WITH TENANT FOR ALL MASTER KEY OR SEPARATE KEY REQUIREMENTS.
GENERAL DOOR/HARDWARE SPECS
GENERAL DOOR HARDWARE LEVER SPECIFICATION
MFG: SCHLAGE
SERIES: SATURN LEVER
FINISH: 626 SATIN CHROMIUM PLATED
STOPS: PROVIDE FLOOR STOPS WHEREVER POSSIBLE (VS. WALL STOP)
GENERAL FLUSH DOOR SPECIFICATION
MFG: MARSHFIELD OR EQUAL
WOOD SPECIES: STAIN GRADE PLAIN SLICED SELECT WHITE MAPLE
VENEER GRADE: A GRADE
CORE: COMPOSITE DOOR AT DOORS WITH LITES, SOLID AT DOORS WITH NO LITES
FINISH: STAIN TO MATCH SAMPLE PROVIDED BY DESIGNER
HARDWARE SETS
A ITEM: EXISTING DOOR HARDWARE TO REMAIN
B ITEM: NEW STOREROOM LOCKSET
C ITEM: NEW INTERIOR PASSAGE SET
D ITEM: NEW MORTISED RESTROOM OCCUPANCY INDICATOR DEADBOLT WITH LEVER HANDLE - SCHLAGE L9496
E ITEM: NEW OFFICE LOCKSET
F ITEM: POCKET DOOR KIT
PULL: TRIMCO 1069 IN SATIN STAINLESS FINISH
G ITEM: LOCKING POCKET DOOR KIT
PULL: TRIMCO 1069 IN SATIN STAINLESS
SCALE:
DOOR ELEVATIONS
3/8"=1'-0"
TYPICAL
INTERIOR DOOR
TYPICAL
INTERIOR DOOR
WITH GLASS
WINDOW
A
TREATMENT
ROOM POCKET
DOORS/WINDOW
WITH GLAZING
2'-4" DOOR
WITH GLAZING
3' DOOR WITH
GLAZING
EXISTING DOOR
TO FIRE RISER VARIES-SEE PLAN
1'-4"2'-0"
WINDOW
A
2'-0"
WINDOW
A
1'-4"
3' POCKET
DOOR WITH
GLAZING
WINDOW
A
2'-0"
WINDOW TYPES
WNDW-A
ITEM: TENANT DOOR LITES, SEE DOOR SCHEDULE FOR SIZE
MATERIAL: 38" TEMPERED CLEAR GLAZING
NOTE: PROVIDE FILM-1 AT ALL GLAZING OPENINGS WITH 3/4" CLEAR BORDER. CONFIRM LOCATIONS WITH
BLOOM STUDIO PRIOR TO INSTALLATION
1
SCALE: N/A
DOOR SCHEDULE2
SCALE:
DETAILED SECTION AT POCKET DOORS
1"=1'-0"
COORDINATE EXACT LOCATION OF UTILITIES
WITH DENTAL EQUIPMENT PROVIDER AND IT
PROVIDER. ENSURE SUFFICIENT CAVITY SPACE
134" X 34" POPLAR TRIM,
PAINTED
3
05/10/18
WAITING
100
CHECK IN
102
ACCESSIBLE
105
CHECK IN
PANO
108
STERILE
116
CONSULT
106
STAFF
124
FIRE
123
RISER
OFFICE
103
PRIVATE
117
OP 6
PRIVATE
118
OP 7
TECHNOLOGY
120
OP 1
110
OP 2
111
OP 3
112
OP 4
113
OP 5
114
RESTROOM
101
RESTROOM
121
LAB
125
EQUIPMENT
122
HALLWAY
119
HALLWAY
115
HANDWASH
109
HALLWAY
104
HALLWAY
107
8'-0"C-2
8'-0"C-2
8'-0"C-2
7'-0"C-2
8'-0"C-2
8'-6"C-1
8'-6"C-1
8'-6"C-1
8'-6"C-1
8'-6"C-1
8'-6"C-1
8'-6"C-1
7'-0"C-2
8'-6"C-1
8'-6"C-1
8'-6"C-1
8'-0"C-2
8'-0"C-2
8'-0"C-2
8'-0"C-2
8'-0"C-2
7'-0"C-2
7'-0"C-2
8'-0"C-2
8'-0"C-2
8'-0"C-2
8'-0"C-2
8'-0"C-2
2'-6"
1'-4"
3'-3" 5"
1'-2"
1'-0" 1'-2"1'-2" 1'-2"
2/A400
TYP
EQ EQ
EQ EQ
EQ EQ
EQ EQ2/A400
2/A400
2/A400
2/A400
2/A400
2/A400
2/A400
2/A400
2/A400
2'-612"2'-7"CENTER FIXTURE
OVER TABLE
PLACE
ACCORDING TO
ARTWORK
PLACE
ACCORDING TO
ARTWORK
2
2
2 3'-6" 1'-10"2'-7"
10'-0"1'-6"3'-1" 3'-1" 5"1'-612" 2'-0" 2'-0"
MO
MO
MO
MO
MO
MO MO
TYP
2
7'-0"C-2
8'-6"C-1
8'-6"C-1
1'-6 12"NOTE: REFER TO ELECTRICAL SHEETS THIS SET
FOR LIGHTING TYPES AND SPECIFICATIONS
NOTE: REFER TO DETAIL 2/A400 FOR DROPPED
SOFFIT DETAILS AND 3/A400 FOR CEILING GRID
SUPPORT DETAILS
REFLECTED CEILING PLAN LEGEND
C-1 AS SPECIFIED
C-2 AS SPECIFIED
CEILING TYPE
CEILING HEIGHT
X'-X"
C-X
BRACING/BLOCKING
ABOVE CEILNG
1
PROVIDE ACOUSTICAL INSULATION 4'-0"
OUT ON BOTH SIDES OF EVERY WALL
ABOVE CEILING
REFLECTED CEILING PLAN KEYED NOTES
2 DRYWALL CASED OPENING AT 7'-0" AFF
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
SF HP
03.05.18
A400
REFLECTED
CEILING PLAN
SCALE: 1/4"=1'-0"
REFLECTED CEILING PLAN1
REFLECTED CEILING PLAN GENERAL NOTES
1. REUSE EXISTING CEILING TILES IN AS IS CONDITION, UNLESS DAMAGED, EXCEPT THOSE AREAS IMPACTED BY NEW
CONSTRUCTION.
2. IN AREAS OF NEW CONSTRUCTION ALL CEILING TILE SHALL EITHER BE ALL NEW OR ALL EXISTING/RELOCATED WITHIN A
ROOM OR AREA - DO NOT MIX EXISTING/RELOCATED WITH NEW CEILING TILE.
3. ALL ACCESS PANELS TO BE IN GRID CEILING WHENEVER POSSIBLE. ANY HARD LID ACCESS PANELS TO BE DISCREET AND
UNOBTRUSIVE IN THEIR LOCATION.
4. FIELD VERIFY WHETHER EXISTING CEILING IS DUCTED OR COMMON AIR PLENUM.
5. MECHANICAL SUBCONTRACTOR SHALL FIELD VERIFY EXISTING MECHANICAL SYSTEM ABOVE NEW GYPSUM BOARD CEILINGS AND
SOFFITS TO ASSURE PROPER HEIGHTS AND ARRANGEMENTS OF EQUIPMENT.
6. SYSTEM TO BE PROPERLY BALANCED PRIOR TO TENANT OCCUPANCY.
7. AT ACOUSTICAL TILE CEILINGS, FIRE SPRINKLER HEADS SHALL MATCH EXISTING TENANT STANDARD STYLE AND FINISH, OR IF
SPRINKLER SYSTEM IS NEW SPRINKLER HEADS SHALL BE SEMI-RECESSED CHROME WITH CHROME ESCUTCHEONS, UNLESS NOTED
OTHERWISE.
8. AT ALL GYPSUM BOARD CEILINGS, FIRE SPRINKLER HEADS SHALL BE CONCEALED FLUSH STYLE IN COLOR TO MATCH CEILING
COLOR. HAVE HEAD PLATES FACTORY PAINTED TO MATCH CEILING COLOR AS NECESSARY.
9. FIELD VERIFY CEILING HEIGHTS FOR CLEARANCES FOR ALL DUCT AND STRUCTURAL REQUIREMENTS. ISSUES ARE TO BE
IMMEDIATELY BROUGHT TO THE ATTENTION OF THE DESIGNER.
10. REFER TO ENGINEERING DRAWINGS FOR LIGHTING LOCATIONS, SPECIFICATIONS, AND NOTES. LIGHTS SHOWN ON THIS PLAN ARE
FOR PLACEMENT ONLY. GENERAL CONTRACTOR SHALL BRING ANY DISCREPANCIES TO THE ATTENTION OF THE DESIGNER.
REFLECTED CEILING PLAN SPECIFICATIONS
C-1 ITEM: NEW CEILING GRID/TILE
MFG: ARMSTRONG DUNE 2ND LOOK II 24"X48" PANELS SCORED TO LOOK LIKE 24"X24" 2722, WITH SUPRAFINE TEGULAR
916" EXPOSED TEE GRID ALL IN COLOR WHITE
LOCATION: REFER TO RCP
C-2
ITEM: GYPSUM BOARD CEILING
LOCATION: REFER TO RCP
3
SCALE:
SECTION AT NON-COVED SOFFIT
3"=1'-0"
SUSPENDED ACOUSTICAL CEILING
GRID CEILING TILE AS SPECIFIED
REFER TO RCP
REFER TO RCP
2
SCALE:
TYPICAL CEILING BRACING DETAIL
1 1/2" = 1'-0"
2"
MAX.
# 12 GA.
HANGER WIRE
@ 4'-0" O.C. &
AT EACH LIGHT
FIXTURE
CROSS TEE
#12 GA. SPLAY WIRE BRACING IN LINE
WITH RUNNER @ 12'-0" O.C. & WITHIN
6'-0" OF FROM EACH WALL.
(TYP. FOR 4)
45° MAX. TYP. FOR 4
MAIN RUNNER
NOTES:
WIRES SHALL BE ATTACHED TO SUSPENDED MEMBERS WITH A MINIMUM OF THREE TURNS.
VERTICAL STRUT SHALL BE INSTALLED AT EACH SET OF SPLAY WIRES - 200 POUND DESIGN FORCE.
FOR EVERY WIRE WHICH CAN NOT BE INSTALLED DUE TO DUCT, ETC., INSTALL MIN. OF BACK TO BACK
1-1/4' COLD ROLLED CHANNELS FOR SPANS EXCEEDING 48 INCHES.
NOTES:
ALL STRUCTURAL MEMBERS OF CEILING SYSTEM SHALL COMPLY WITH THE DIRECT HUNG LOADING AND
DEFLECTION TEST REQUIRED IN ASTM C635/C636
N
05/10/18
WAITING
100
CHECK IN
102
ACCESSIBLE
105
CHECK IN
PANO
108
STERILE
116
CONSULT
106
STAFF
124
FIRE
123
RISER
OFFICE
103
PRIVATE
117
OP 6
PRIVATE
118
OP 7
TECHNOLOGY
120
OP 1
110
OP 2
111
OP 3
112
OP 4
113
OP 5
114
RESTROOM
101
RESTROOM
121
LAB
125
EQUIPMENT
122
HALLWAY
119
HALLWAY
115
HANDWASH
109
HALLWAY
104
HALLWAY
107
A
A
W
22
2
4/A800 13/A80014/A8004/A8001/A8003/A801
8/A8003/A8001/A8018/A8013
w
w
2'-0"
1'-0"
1'-8"
1'-0"
2'-0"
1'-9"1'-9"4/A8015/A801
11/A800
2/A801
7/A801
9/A801
2/A8009/A8006/A80112/A800 5A80010/A8007/A8006/A8002'-0"2'-1"2'-0"
25"
2'-0" 1'-6"6'-0"4'-0"4
2'-8"1'-6"1'-9"1'-9"
NOTE: REFER TO SPECS FOR BASE TYPES AND
LOCATIONS
NEW MILLWORK, REFER
TO ELEV/DETAILS
MILLWORK ELEVATION
SYMBOL
MILLWORK/FINISH PLAN LEGEND
WALL FINISH SYMBOL
FLOOR FINISH SYMBOL
X/AX.X
NOTE: ALL WALLS TO BE PAINTED UNLESS
NOTED OTHERWISE
XXX-X
XXX-X
CPT-1
LVT-1
TILE-1
TILE-2
REFER TO ELEVATIONS FOR
SPECIFIC LOCATIONS
TILE-4
REFER TO ELEVATIONS FOR
SPECIFIC LOCATIONS
MAT-1
MILLWORK/FINISH PLAN KEYED NOTES
PROVIDE PLYWOOD WALL BACKING
CONCEALED AT WALL FOR FUTURE
TENANT-MOUNTED EQUIPMENT
FRONT WALL OF RECEPTION DESK
SHALL BE FRAMED/DRYWALLED, SEE
ELEVATIONS AND SECTIONS. GC TO
COORDINATE SCOPE/DETAILS WITH
MILLWORKER
ALL EXPOSED CORNERS SHALL BE
RADIUSED TO PREVENT INJURY (TYPICAL)
PROVIDE FILM AT EXISTING WINDOW TO
REMAIN
1
2
3
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
SF HP
03.05.18
A500
MILLWORK/
FINISH PLAN
SCALE: 1/4"=1'-0"
MILLWORK/FINISH PLAN1
MILLWORK/FINISH PLAN GENERAL NOTES
MILLWORK
1. ALL OF THE MATERIALS USED IN THIS PROJECT SHALL BE LOW OR NO VOLATILE ORGANIC COMPOUND (VOC), AND LOW
ODOR PRODUCTS INCLUDING BUT NOT LIMITED TO: ADHESIVES, CAULKS, STAINS, LATEX AND OIL BASED PAINTS, PARTICLE
BOARD, AND CLEANING CHEMICALS.
2. PROVIDE SHOP DRAWINGS ON ALL MILLWORK ITEMS, PRIOR TO ORDERING OF MATERIAL AND FABRICATION OF
MILLWORK, FOR INTERIOR DESIGNER COMMENTS AND APPROVAL. SHOP DRAWINGS THAT ARE NOT BOTH RECEIVED AND
APPROVED BY INTERIOR DESIGNER SHALL BE UNDERSTOOD TO BE "NOT APPROVED" BY INTERIOR DESIGNER.
3. PROVIDE 4 SUBMITTAL SAMPLES OF ALL MILLWORK FINISHES FOR INTERIOR DESIGNER APPROVAL PRIOR TO ORDERING OF
MATERIAL AND FABRICATION OF MILLWORK. SAMPLES THAT ARE NOT BOTH RECEIVED AND APPROVED BY INTERIOR
DESIGNER SHALL BE UNDERSTOOD TO BE "NOT APPROVED" BY THE INTERIOR DESIGNER.
4. FIELD VERIFY ALL MILLWORK LOCATIONS AND DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION.
5. ALL MILLWORK SHALL HAVE CONCEALED HINGES (UNLESS NOTED OTHERWISE). FLUSH MOUNT LOCKS IF NOTED ON
ELEVATIONS. USE FULL EXTENSION ACCURIDE DRAWER SLIDES FOR ALL MILLWORK DRAWERS. ALL MILLWORK WITH 32MM
SYSTEM SPECIFIED SHOULD BE PROVIDED WITH CONCEALED STEEL SHELF PINS. PLASTIC CLIPS, ETC. ARE NOT ACCEPTABLE.
6. ALL MILLWORK HEIGHTS SHOWN SHALL BE ABOVE FINISHED FLOOR. ALL MILLWORK HEIGHTS, WIDTHS, AND DEPTHS SHALL
COMPLY WITH ADA REQUIREMENTS.
7. ALL PLASTIC LAMINATE CABINETS SHALL BE AWI CUSTOM GRADE, FLUSH OVERLAY DESIGN, CONSTRUCTED FROM MEDIUM
DENSITY PARTICLE BOARD WITH THERMOFUSED MELAMINE INTERIORS. MELAMINE COLOR: WHITE ALL STAIN GRADE
MILLWORK SHALL BE AWI PREMIUM GRADE.
8. ALL BASE CABINET COUNTERTOPS TO BE SCRIBED TO WALL WHEREVER BACKSPLASH DOES NOT OCCUR.
9. PROVIDE 2" BLACK PLASTIC GROMMETS AT PLASTIC LAMINATE MILLWORK AND PROVIDE 2" BLACK METAL GROMMETS AT
STAIN GRADE MILLWORK WHERE NOTED.
10. SEAMS FOR STONE TOPS FOR SHALL BE IN LOCATIONS SHOWN BY INTERIOR DESIGNER. IF LOCATIONS ARE UNCLEAR,
CONTACT INTERIOR DESIGNER BEFORE DETERMINING SEAM LOCATIONS.
FINISHES
11. FINISH ALTERNATES AND SUBSTITUTIONS SHALL NOT BE USED UNLESS WRITTEN APPROVAL BY INTERIOR DESIGNER IS
OBTAINED BY GENERAL CONTRACTOR.
12. ALL OF THE MATERIALS USED IN THIS PROJECT SHALL BE LOW OR NO VOLATILE ORGANIC COMPOUND (VOC), AND LOW
ODOR PRODUCTS INCLUDING BUT NOT LIMITED TO: FLOORING AND BASE ADHESIVES, CARPET, ADHESIVES, CARPET
BACKINGS, LATEX CAULK, STAINS, LATEX AND OIL BASED PAINTS, WALLCOVERING ADHESIVES, PARTICLE BOARD, AND
CLEANING CHEMICALS.
13. PROVIDE 4 SUBMITTAL SAMPLES OF ALL FINISHES FOR INTERIOR DESIGNER APPROVAL PRIOR TO ORDERING AND
INSTALLATION OF MATERIALS. SAMPLES THAT ARE NOT BOTH RECEIVED AND APPROVED BY INTERIOR DESIGNER SHALL BE
UNDERSTOOD TO BE "NOT APPROVED" BY INTERIOR DESIGNER.
14. PROPERLY PREPARE ALL FLOORS TO RECEIVE NEW FLOORING. REMOVE EXISTING GLUE, CLEAN FLOORS, FLOAT, PATCH
AND REPAIR CRACKS AS REQUIRED.
15. ALL FLOORING TRANSITIONS SHALL BE FLUSH HEIGHT. PROVIDE VINYL TRANSITION STRIPS AT ALL VCT TO CARPET
TRANSITIONS.
16. PROVIDE SEAMING DIAGRAM DRAWINGS FOR ALL CARPET AREAS, PRIOR TO ORDERING OF MATERIAL AND INSTALLATION,
FOR INTERIOR DESIGNER COMMENTS AND APPROVAL. SEAMING DIAGRAM DRAWINGS THAT ARE NOT BOTH RECEIVED
AND APPROVED BY INTERIOR DESIGNER SHALL BE UNDERSTOOD TO BE "NOT APPROVED" BY INTERIOR DESIGNER.
17. TOLERANCES GREATER THAN 1" ON PATTERNED CARPET GOODS WILL NOT BE ACCEPTED.
18. ALL CARPET SHALL BE UNROLLED AND OUTGASED FOR 3 TO 5 DAYS, PRIOR TO DELIVERY TO THE JOBSITE FOR
INSTALLATION.
19. PROVIDE SHOP DRAWINGS ON NEW WOOD BASE, PRIOR TO ORDERING OF MATERIAL AND FABRICATION, FOR INTERIOR
DESIGNER COMMENTS AND APPROVAL. SHOP DRAWINGS THAT ARE NOT BOTH RECEIVED AND APPROVED BY INTERIOR
DESIGNER SHALL BE UNDERSTOOD TO BE "NOT APPROVED" BY THE INTERIOR DESIGNER
20. ALL GYPSUM BOARD SURFACES SHALL BE TWO COATS, LATEX, PREP SURFACES PER PAINT MANUFACTURER
RECOMMENDATIONS. ALL METAL, TRIM AND SURFACES PER PAINT MANUFACTURER RECOMMENDATIONS. ALL METAL,
TRIM AND SASH SHALL BE TWO COATS, OIL BASE, OVER MANUFACTURER RECOMMENDED PRIMER COAT. ALL
APPLICATIONS SHALL USE MANUFACTURER RECOMMENDED EXTENDER AGENTS IN ORDER TO REDUCE BRUSH MARKS.
MILLWORK/FINISH PLAN SPECIFICATIONS
MILLWORK/CARPENTRY
NOTE: ALL CABINETRY TO HAVE SOFT CLOSE (BLUM BLUMOTION OR SIMILAR) HARDWARE
PULLS-1 CABINET PULLS: HAFELE 117.97.463 EUROPEAN BAR PULL IN MATTE CHROME 160 CENTERS
LOCATION: AT ALL CUSTOM CABINETRY DRAWERS/CABINETS EXCEPT STAFF 124 AND LAB 125
PULLS-2 CABINET PULLS: 3 ½" WIRE CABINET DOOR/DRAWER PULLS IN SATIN STAINLESS FINISH. MOUNT PULLS PULLS
CENTERED HORIZONTALLY ON DRAWERS AND VERTICALLY ON CABINET DOORS.
LOCATION: ALL AREAS NOT NOTED OTHERWISE
PLM-1 PLASTIC LAMINATE: WILSONART PEARL SOAPSTONE 4886-38
LOCATION: REFER TO ELEVATIONS THIS SET
PLM-2 PLASTIC LAMINATE: WILSONART STUDIO TEAK 7960
LOCATION: REFER TO MILLWORK ELEVATIONS THIS SET
QTZ-1 QUARTZ COUNTERTOP: WILSONART VESUVIUS Q1017, 3CM THICKNESS, EASED EDGE, WATERFALL EDGE PER
ELEVATIONS
LOCATION: REFER TO MILLWORK ELEVATIONS THIS SET
PERF-1 PERFORATED METAL: MCNICHOLS SLOTTED PERFORATED, 16 GUAGE PLAIN STEEL, .1250" X 1" ROUND END SLOT
SIDE STAGGERED 36"X120"
LOCATION; REFER TO MILLWORK ELEVATIONS - AT ALL VENTILATED CABINETS
WOOD-1 WOOD STAIN: PLAIN SLICED SELECT WHITE MAPLE, STAINED TO MATCH ARCH SAMPLE
LOCATION: AT ALL WOOD STAINED ELEMENTS
FLOORING
NOTE: TRANSITION STRIPS (PERMANENTLY FASTEN THROUGH ANCHOR WITH SCREWS AND WASHERS)
AT CARPET/RESILIENT FLOOR TRANSITIONS OF SAME HEIGHT: SCHLUTER SCHEINE
AT CARPET/RESILIENT FLOOR TRANSITIONS WHERE CARPET IS LOWER: SCHLUTER RENO-TK
AT SHEET VINYL/CARPET TRANSITIONS: SCHLUTER RONDECK
LVT-1 LUXURY VINYL TILE: MOHAWK GROUP TRENTA C0051 172 DUNE
NOTE: ENSURE PRODUCT IS INSTALLED PER MANUFACTURER'S RECOMMENDATIONS
NOTE: COORDINATE SPECIFIC INSTALLATION LAYOUT WITH BLOOM STUDIO PRIOR TO INSTALLATION
CPT-1 CARPET TILE: SHAW CONTRACT CARPET TILE, 24X24, DESIGN JOURNEY, STYLE 5T096, CLOTH TILE COLOR 96585
BAYON, BRICK INSTALLATION. PROVIDE (1) EXTRA BOX TO TENANT AT PROJECT COMPLETION FOR OWNER STOCK
NOTE: ENSURE PRODUCT IS INSTALLED PER MANUFACTURER RECOMMENDATIONS
MAT-1 WALK-OFF MAT: BOLYU ACCESS WALK-OFF TILE, COLOR AX903 CHANNEL, VERTICAL ASHLAR INSTALLATION
NOTE: ENSURE PRODUCT IS INSTALLED PER MANUFACTURER RECOMMENDATIONS
MILLWORK/FINISH PLAN SPECIFICATIONS CONTINUED
TILE/STONE
NOTE: BEVEL AND SMOOTH EDGES OF ALL FIELD CUT TILE AT ALL TILE TO CARPET TRANSITIONS. TILE AND CARPET SHALL BE FLUSH HEIGHT.
TILE-1A TILE: MARAZZI ESSENTIALS BASIC BLACK IN 12X24 SIZE, INSTALL IN BRICK PATTERN. COORDINATED DIRECTION OF PATTERN ONSITE.
GROUT: THICKNESS AS RECOMMENDED BY MANUFACTURER, CUSTOM BUILDING PRODUCTS COLOR #60 CHARCOAL, SEAL GROUT
TILE-1B TILE: MARAZZI ESSENTIALS BASIC BLACK COVE BASE 6"X12"
GROUT: THICKNESS AS RECOMMENDED BY MANUFACTURER, CUSTOM BUILDING PRODUCTS COLOR #60 CHARCOAL, SEAL GROUT
TILE-2 TILE: MARAZZI PRESERVATION AGED WALNUT 9" X 36"
GROUT: CUSTOM BUILDING PRODUCTS COLOR #60 CHARCOAL THICKNESS AS RECOMMENDED BY MANUFACTURER, SEAL GROUT
TILE-3 TILE: ANT TILE TR1-MB 1" MATTE BLACK TRIANGULAR PORCELAIN MOSAIC TILE
GROUT: CUSTOM BUILDING PRODUCTS COLOR #60 CHARCOAL THICKNESS AS RECOMMENDED BY MANUFACTURER, SEAL GROUT
TILE-4 TILE: AMERICAN OLEAN BRICKTOWN 4X8 FIELD TILE ARCTIC BLEND
GROUT: CUSTOM BUILDING PRODUCTS COLOR #542 GRAYSTONE THICKNESS AS RECOMMENDED BY MANUFACTURER, SEAL GROUT
SCH-1 SCHLUTER: JOLLY AGR GRAPHITE ANODIZED ALUMINUM
RUBBER BASE/CHAIR RAIL
BASE-1 RUBBER BASE: JOHNSONITE MILLWORK SERIES REVEAL (4" TALL) IN COLOR BLACK
LOCATION: AT ALL AREAS OF CARPET AND RESILIENT FLOORING UNLESS NOTED OTHERWISE
FIBER REINFORCED PANELS
FRP-1 ITEM: FIBER REINFORCED PANELS - MARLITE STANDARD FRP PANELS IN COLOR P100 WHITE, PVC TRIM MOULDING
LOCATION: TO 8'-0" HIGH AT ALL WALLS OF EQUIPMENT 122
GLAZING
FILM-1 ITEM: VINYL FILM AT GLAZING TO APPEAR 'FROSTED - 3M FASARO MILKY WHITE MILANO
LOCATION: REFER TO WINDOW TYPES SHEET A201 THIS SET
PAINT
GENERAL PAINTING SHEEN NOTES:
FLAT SHEEN AT ALL PAINTED CEILINGS, UNLESS NOTED OTHERWISE
EGGSHELL SHEEN AT ALL WALLS, UNLESS NOTED OTHERWISE
PT-0 DRYWALL CEILING PAINT: SHERWIN WILLIAMS SWISS COFFEE
LOCATION: DRYWALL CEILINGS, COORDINATE WITH BLOOM STUDIO
PT-1 OVERALL PAINT: SHERWIN WILLIAMS SW 7646 FIRST STAR
LOCATION: OVERALL WALL COLOR EXCEPT AS NOTED OTHERWISE
PT-2 ACCENT PAINT: SHERWIN WILLIAMS SW7664 STEELY GRAY
LOCATION: AT ACCENT WALLS TO BE DETERMINED ONSITE
N
05/10/18
WAITING
100
CHECK IN
102
ACCESSIBLE
105
CHECK IN
PANO
108
STERILE
116
CONSULT
106
STAFF
124
FIRE
123
RISER
OFFICE
103
PRIVATE
117
OP 6
PRIVATE
118
OP 7
TECHNOLOGY
120
OP 1
110
OP 2
111
OP 3
112
OP 4
113
OP 5
114
RESTROOM
101
RESTROOM
121
LAB
125
EQUIPMENT
122
HALLWAY
119
HALLWAY
115
HANDWASH
109
HALLWAY
104
HALLWAY
107
A
A
WwCHAIRHEADCHAIRHEADCHAIRHEAD
CHAIRHEADCHAIRHEAD CHAIRHEADCHAIRHEADw
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
SF HP
03.05.18
A600
FURNITURE
PLAN
SCALE: 1/4" = 1'-0"
FURNITURE/EQUIPMENT LAYOUT1
FURNITURE PLAN GENERAL NOTES
1. ALL FURNITURE SHOWN IS FOR REFERENCE ONLY. GC TO COORDINATE FURNITURE AND EQUIPMENT PLACEMENT AND
REQUIREMENTS WITH TENANT AND VENDORS
N
05/10/18
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
SF HP
03.05.18
A700
CONSTRUCTION
DETAILS
8
9 3
7 4
2 5
6
SCALE:
NON-BEARING METAL STUD BRACING
1"=1'-0"
STUD 45° KICKERS @ 5'-0" ON CENTER
20G TOP TRACK BY PROVIDING 3-5/8" 20 GA. METAL
CONTRACTOR CAN SUBSTITUTE 16G TOP TRACK WITH
ALTERNATE:
PERPENDICULAR PARTITION
OTHERWISE BRACED BY AN INTERSECTION OR
DIRECTIONS, @ 10' 0.C. WHEN PARTITION IS NOT
USE 3 5/8" 20 GA. METAL STUDS IN BOTH 45°
SUMMARY:
@ < 35° USE (1) A34
@ > 35° USE (2) A34
(45° MAX)
LENGTH = 12'-0" @ 10' O.C.
3 5/8" x 20G IC Max
STUDS.
INT. NON-BRNG
MT SECTION
16G TRACK
A34
TRY SUPPORTS @ 10'-0" O.C.
Vmax = 150#
Mmax = 267 '#
max = .13"
Rx = 1.143(25)(10) = 286#
AT 45° = 400#
Ma = 782 '#
Rmax = 228#
= .054"
4
(29E6)(.725)
max = .0065(2.08)(96)
2 Mmax = .107(25)(8) = 171 '#
Vmax = .607(5)(5)(8) = 120#
TRY SUPPORTS @ 8'-0" O.C.
* DETERMINE MAX SPAN FOR 16G TRACK - "MT" SECTION
USE 3 5/8" X 25 GA. @ 24" 0.C. (I.C. SECTION)
q=5 PSF (INTERIOR)
H=10'
SCALE:
EXTENDED PARTITION
3"=1'-0"
SOUND ATTENTUATION BATTS AT CAVITY
AND OVER CEILING TILE 4'-0" OUT ON
EACH SIDE OF PARTITION
#8 DRYWALL SCREWS AT 8" O.C.
ATTACH GYPSUM BOARD WITH 1 1/4"
3 5/8" 25 GAUGE METAL STUDS 24" O.C.
5/8" TYPE 'X' GYPSUM BOARD EACH SIDE OF
.145" ROUND BY 5/8" LONG
FASTENERS TOP TRACK:
HILTI INC., ICC2006.ESR1663
FASTENERS BOTTOM TRACK:
HILTI INC., ICC2006.ESR1663
STRUCTURAL DECK WITH 22 CALIBER
AN INTERSECTING PARTITION. ATTACH TO
EXCEEDS 10'-0" IN LENGTH WITH OUT
CALIBER SHOTS 24"ON CENTER
CONCRETE FLOOR WITH 22 SHORT
METAL STUD RUNNER ANCHORED TO
8'-0" ON CENTER. REFER TO DETAIL.
SHORT SHOTS AND RIVET TO T-BAR
DIRECTIONS @ 10'-0" ON CENTER WHEN
STUDS @45° ALTERNATING IN BOTH
BRACE TOP TRACK WITH 3-5/8" METAL
SCHEDULED BASE REFER TO SPEC'S
METAL TOP TRACK
CEILING AS SPECIFIED.
(6" 20 GAUGE AT PLUMBING PARTITIONS)
NOTE: USE 6" STUDS WHERE NEEDED FOR
PLUMBING OR ELECTRICAL PANEL
SCALE:
STEEL TUBE VERTICAL BRACING
3"=1'-0"
FOR EXPANSION BOLTS
PRIOR TO DRILLING
NOTE: DETERMINE LOCATION
OF TENDONS IN POST
TENSIONED CONCRETE SLAB
SEE WALL TYPE FOR
HEIGHT
STL BASE PLATE
3 1/2"x5"x3/8"
2"x2"x1/8" STEEL TUBE
1/8
AND FLAT WASHER - TYP.
EMBEDMENT W/ HEX NUT
(4) 3/8"Ø EXP BOLTS X 3"
5"
1"
PLAN
ELEVATION
2"
TOP OF SLAB
SCALE:
GRAB BAR SUPPORTS
FULL
METAL STUD
SHOWER GRAB BARS.
BOTH TUB/SHOWER AND ACCESSIBLE
FOR WC GRAB BARS AND FOR
TO BE PROVIDED IN ALL UNITS
NOTE: STEEL BACK PLATES ARE
LOAD
SUPPORT A 250 LBF
GRAB BAR SHALL
METAL STUDS
SCREW ATTACHED TO
STEEL BACK PLATE
OF GRAB BAR
1/8"x3"-1/2"xLENGTH
WALL
FINISH FACE OF
INSTRUCTIONS.
INSTALL PER MANUFACTURER
SUPPLIED BY MANUFACTURER
PLATE AND SCREWS
GRAB BAR ATTACHMENT
SCALE:
ACCESSIBLE CLEARANCES
NTS
MAX
7-9"
AT 48" AFF MAX AT ALL ACCESSABLE TOILETS.
8. A PARAPHERNALIA SHELF SHALL BE PROVIDED
2003 ANSI2003 ANSI
18" MIN39"-41" 36"MIN 2003 ANSI
7"MIN-9"MAX
MAX
19"
18" O.C.
LAV.
LAV. or D.F. SHOWER2003 ANSI1992 ANSIMOUNTED W.C.75"-79" WALL48"MIN. CLR.7. WATER CLOSET DOORS SHALL BE EQUIPED
WITH AN AUTOMATIC CLOSING DEVICE
A LOAD OF 250 POUNDS.
4. GRABBARS MUST SUPPORT
A MIN. OF 14" AT A MAX. 17"A.F.F.
A.D.A.
18" O.C.
6"
max.
12"
min.
36"33-36"54" MIN.
36" MAX
MAX
4"
60"
32"
MIN. 56"MIN WALLMOUNTED W.C.MOUNTED W.C. RIM PROJECTING FROM THE WALL
6. URINALS SHALL HAVE ELONGATED
MIN.
PROVIDE MAX 9" TOESPACE
5. STALL PARTITIONS SHALL
59"MIN FLOORSPACE
FLOOR
CLEAR
42"MIN
BELOW LAVATORY
3. ELIMINATE SHARP EDGES OF CORNERS
OF ELECTRONIC CONTROL TYPE
2. FAUCETS SHALL BE PUSH/LEVER
UNDER LAVATORY
1. INSULATE ANY EXPOSED PIPING 30" MIN48" MIN
MIN
17"
SPACE
FLOOR
CLEAR
MIRROR
MIN
TOWEL
PAPER
48" MAX6" MIN
17" MIN 40" MAX34" MAX29" MIN27" MIN8"9" MINT.P.
max.
12" min19"min17"33-36"39"-41"
36" CLR
36" CLR48" MIN 36" MIN SCALE:
ACOUSTICAL PARTITION STC 57
3"=1'-0"
TEST REPORT OL11-1103
3 5/8" 25 GUAGE STEEL STUDS
AT 16" O.C.
(2) LAYERS 5/8" DRYWALL AT
ONE SIDE
(1) LAYER 'QUIETROCK ES'
SEAL WITH QUIETSEAL PRO AND
QUIET PUTTY
ACHIEVES STC 57
R-19 FULL BATT INSULATION AT
CAVITY
SCALE:
PARTIAL HEIGHT RECEPTION DESK WALL
3"=1'-0"
1/2" DIA. EXPANSION ANCHORS @
2x1/8x6" PLATE WITH 2-1/2"LONG
TS 2x2x3/16" BRACE WELDED TO
CORNER BEAD
NOTE:
CAP
PLAN
BASE
16" ON CENTER.
SIDE OF 3 5/8" 25GA. METAL STUDS
1 LAYER 5/8" GYPSUM BOARD EACH
4'-0" CENTERS
1/4"
STUD RUNNER
CALIBER SHOTS 24" ON CENTER
TO CONCRETE FLOOR WITH 22 SHORT
METAL BOTTOM TRACK ANCHORED
COORDINATE MILLWORK TOP/ATTACHMENT WITH
FASTENERS BOTTOM TRACK:
REFER TO
MILLWORK
HILTI INC., ICC2006.ESR1663
SELECTED MILLWORKER PRIOR TO FRAMING
NOTE: REFER TO DETAIL 7/A700 FOR STEEL
TUBE VERTICAL BRACING INFORMATION
SCALE:
WALL BRACING AT CONCRETE DECK
3"=1'-0"
METAL TOP TRACK
NOTE: PROVIDE (1) BRACE IN EACH DIRECTION ABOVE
EACH DOOR JAMB. (TOTAL OF 4 BRACES PER
DOOR OPENING)
USE WHERE PARTITION EXTENDS MORE THAN
12'-0" WITHOUT LATERAL SUPPORT OR AS
NOTED
BOTTOM OF EXISTING
CONCRETE DECK
ATTACH TO STRUCTURAL DECK WITH 22
CAL. SHORT SHOTS & RIVET TO T-BAR
8'-0" ON CENTER. REFER TO NON-
BRACE TOP TRACK WITH 3-5/8" METAL
STUDS @45° ALTERNATING IN BOTH
DIRECTIONS @10'-0" ON CENTER WHEN
PARTITION EXCEEDS 10'-0" IN LENGTH
WITH OUT AN INTERSECTING PARTITION.
BEARING BRACING DETAIL
HILTI INC., ICBO NO. ER-4780
HILTI INC., ICBO NO. ER-2388 OR
FASTENERS TOP TRACK:
.145" ROUND BY 5/8" LONG
(OR EQUAL)
1
SCALE:
TYPICAL METAL STUD FASTENING
FULL
FASTENERS TOP TRACK:
.145" ROUND BY 5/8" LONG
HILTI INC. IBC2006.ESR1663
FASTENERS BOTTOM TRACK:
HILTI INC., IBC2006.ESR1663
05/10/18
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
SF HP
03.05.18
A800
INTERIOR
ELEVATIONS
AIRWATER
(F)
(F)
(F)
(F)
SCALE:
RECEPTION DESK FRONT
3/8"=1'-0"
1
SCALE:
RECEPTION DESK BACK WALL
3/8"=1'-0"
3
SCALE:
RESTROOMS
3/8"=1'-0"
4
SCALE:
ACCESSIBLE CHECKOUT
3/8"=1'-0"
7
SCALE:
ACCESSIBLE CHECKOUT BACK WALL
3/8"=1'-0"
9
SCALE:
HAND WASH 109
3/8"=1'-0"
6
SCALE:
LAB EAST
3/8"=1'-0"
10
SCALE:
LAB SOUTH
3/8"=1'-0"
11
SCALE:
OFFICE
3/8"=1'-0"
12
SCALE:
STAFF
3/8"=1'-0"
13
SCALE:
STAFF LOCKERS
3/8"=1'-0"
14
QTZ-1 QTZ-1
QTZ-1
PLM-1 TILE-1
TILE-1
TILE-2 TILE-2
TILE-4
PLM-1 PLM-1
PLM-1 PLM-1 PLM-1
PLM-1
PLM-1
PLM-2
PLM-2
PLM-2
PLM-2
PLM-2
PLM-2
PLM-2 PLM-2
PLM-2
PLM-2 PLM-2
PLM-2
PLM-2
TILE-3 TILE-3
ADJUSTABLE MELAMINE
SHELVING ON WALL
STANDARDS
LOCKABLE
CABINET
SCH-1
RR-6
RR-2
RR-5
SCALE:
ACCESSIBLE WORK STATION
3/8"=1'-0"
8
QTZ-1
PLM-1
(F)
PLM-2
(B)
QTZ-1
PLM-1
SCALE:
RECEPTION DESK BACK SIDE
3/8"=1'-0"
2
SCALE:
RESTROOM 121 SHOWER ELEVATION
3/8"=1'-0"
5
WATERFALL
EDGE
PASS THRU
CABINETS
PASS THRU
CABINETS
TILE-1B
6" 1'-6"
CLR
WATERFALL
EDGE
PERF-1
40" CLR DISHWASHER
3'-0"
INTEGRAL ATTACHED TOE
KICK AND NO BASE AT SINK
CABINET
NOTE: PROVIDE MATCHING
3MM PVC EDGE AT
COUNTERTOPS THIS ROOM
NOTE: PROVIDE MATCHING
3MM PVC EDGE AT
COUNTERTOPS THIS ROOM
TILE-1B
TILE-1B
TILE-1BTILE-1B
PREFAB SHOWER ENCLOSURE- REFER TO
PLUMBING SHEETS THIS SET
SOFFIT @ 7'-0"
EQ EQ EQ EQ
05/10/18
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
SF HP
03.05.18
A801
INTERIOR
ELEVATIONS
SCALE:
WAITING NORTH
3/8"=1'-0"
3
SCALE:
WAITING EAST
3/8"=1'-0"
4
SCALE:
CONSULT NORTH
3/8"=1'-0"
1
SCALE:
CONSULT SOUTH
3/8"=1'-0"
2
SCALE:
BEVERAGE STATION
3/8"=1'-0"
5
QTZ-1
QTZ-1
TILE-4
PLM-2
1'-1"
CLR
ARTWORK BY TENANT
ARTWORK BY TENANT
WATER COOLER
BY TENANT (12.5")
X 12" X 38"
SCALE:
STERILIZATION
3/8"=1'-0"
6
SCALE:
STERILIZATION
3/8"=1'-0"
7
SCALE:
STERILIZATION
3/8"=1'-0"
8
AIR
RR-4
SOFFIT @ 7'-0"
PLM-1
PLM-2
PLM-2
PULLOUT TRASH/BIOHAZARD DRAWER
HAFELE 502.74.212 WASTE BIN PULLOUT
HAFELE 502.15.250 FOOT PEDAL
NOTE: PROVIDE MATCHING
3MM PVC EDGE AT
COUNTERTOPS THIS ROOM
PERF-1
PERF-1
SOFFIT @ 7'-0"
PLM-1
SOFFIT @ 7'-0"
PLM-1
CAULK AND FULLY SEAL ALL
SEAMS ABOVE, BELOW, AND
AROUND STERILIZERS TO
REDUCE DAMAGE FROM
STEAM
INTEGRAL ATTACHED
TOE KICK NO BOTTOM
AT CABINET
9
SCALE:
TECHNOLOGY CLOSET SHELVING
3/8"=1'-0"
ADJUSTABLE WHITE
MELAMINE
SHELVING ON
STANDARDS
NOTE: PROVIDE MATCHING
3MM PVC EDGE AT
COUNTERTOPS THIS ROOM
NOTE: PROVIDE MATCHING
3MM PVC EDGE AT
COUNTERTOPS THIS ROOM
PERF-1
PULL-OUT
SHELF TO
SUPPORT 50LBS
OF EQUIPMENT
05/10/18
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
SF HP
03.05.18
A900
MILLWORK/
DETAILS
6 3
2
1
SCALE:
SECTION AT SINK
1"=1'-0"
SINK AS SPECIFIED
TOE KICK TO MATCH CABINET FACE
MELAMINE AS SPECIFIED
BACK SPLASH TO MATCH COUNTERTOP
COUNTERTOP AS SPECIFIED
FALSE DRAWER PANEL
WHERE SHOWN ON ELEVATIONS
CABINET DOOR
WITH SOFT CLOSE WHERE INDICATED
BLUM OR EQUAL SELF CLOSING HINGE
WHERE INDICATED IN ELEVATIONS
SCALE:
SECTION AT CABINETS W/ LIGHT COVE
1"=1'-0"
SELF CLOSING HINGE WITH SOFT CLOSE WHERE INDICATED
CLR.
NAILER
1/4" BACK
SYSTEM
ADJUSTABLE SHELF ON 32MM
MELAMINE AS SPECIFIED
11"
12-3/4"
PROVIDE 2" 'LIP' TO CONCEAL UNDERCABINET
LIGHT AS SPECIFIED. WHEN DOOR IS IN OPEN
POSITION, LIGHT SHALL STILL BE CONCEALED WITH
A FINISHED-FACE PANEL (MATCH CABINET
EXTERIOR))
UNDERCABINET LIGHT AS SPECIFIED IN ELECTRICAL
DRAWINGS THIS SET
SCALE:
SECTION AT MICROWAVE CABINET
1"=1'-0"
ALL SIDES
MICROWAVE CABINET
PROVIDE POWER FOR M.W.
12-3/4"
11"
MELAMINE AS SPECIFIED
ADJUSTABLE SHELF ON 32MM
SYSTEM
1/4" BACK
BLUM OR EQUAL SELF CLOSING
HINGE WITH SOFT CLOSE WHERE INDICATED
NAILER
1'-6"
PLM-1
SCALE:
SECTION AT DRAWER BANK
1"=1'-0"
COUNTERTOP AS SPECIFIED
BACK SPLASH TO MATCH COUNTERTOP
MELAMINE AS SPECIFIED
HARDWARE AS SPECIFIED
TOE KICK TO MATCH CABINET FACE
(WHERE INDICATED IN ELEVATIONS)
QUANTITY AND
CONFIGURATION OF
DRAWERS AS
INDICATED IN
ELEVATIONS.
NOTE: WHERE DRAWER IS
INDICATED AS TALLER IN HEIGHT,
PROVIDE HEAVY DUTY GLIDES
GLIDES WITH SOFT CLOSE WHERE INDICATED
BLUM OR EQUAL FULL EXTENSION DRAWER
SCALE:
SECTION AT TYP CABINET W DRAWER
1"=1'-0"
MATERIAL
BACK SPLASH WHERE INDICATED IN ELEVATIONS
BLUM OR EQUAL FULL EXTENSION
MELAMINE AS SPECIFIED
DRAWER GLIDES WITH SOFT CLOSE WHERE
32MM SYSTEM
ADJUSTABLE SHELF ON
WITH SOFT CLOSE WHERE INDICATED
BLUM OR EQUAL SELF CLOSING HINGE
TOE KICK TO MATCH CABINET FACE
AS SPECIFIED
INDICATED
5
4
SCALE:
SECTION AT TYPICAL UPPER CABINETS
1"=1'-0"
NAILER
1/4" BACK
SYSTEM
ADJUSTABLE SHELF ON 32MM
MELAMINE AS SPECIFIED
SELF CLOSING HINGE WITH SOFT CLOSE WHERE INDICATED
8
7
SCALE:
METAL BRACKET DETAIL
3"=1'-0"
LOCATIONS
1/8
METAL STUD
ATTACHED TO VERTICAL
STEEL PLATE
STEEL TUBE WELDED TO
1 1/4" X 1 1/4" X 1/8"
AS REQUIRED AT SUPPORT
ADDITIONAL METAL STUDS
NOTE: VERIFY AND PROVIDE
1/8" THICK STEEL PLATE
SCALE:
SECTION AT COUNTER
3/4"=1'-0"
STEEL STUD
CAULK JOINT.
MAX. 1/8" W. CONTINUOUS
BRACKET ATTACHED TO
STEEL TUBULAR SUPPORT
SCRIBE COUNTER TO WALL
COUNTERTOP AS SPECIFIED
REFER TO DETAIL 9/A900
9
10
SCALE:
SECTION AT TYPICAL BASE CABINET
1"=1'-0"
MATERIAL
WITH SOFT CLOSE WHERE INDICATED
BLUM OR EQUAL SELF CLOSING HINGE
ADJUSTABLE SHELF ON 32MM
SYSTEM
MELAMINE AS SPECIFIED
AS SPECIFIED
BACK SPLASH WHERE INDICATED IN ELEVATIONS
SCALE:
SECTION AT RECEPTION DESK
1 1/2" = 1'-0"
34" X 34" X 18" STL. SUPPORT BRACKET
NOTE: PROVIDE WIRE MANAGEMENT
SYSTEM FOR POWER AND
COMMUNICATION LINES
212" X 3" X 18" STL. ANGLE SUPPORT
REFER TO MILLWORK PLAN
WALL CONSTRUCTED BY
FRAMER/DRYWALLER
PROVIDE STEEL TUBE SUPPORTS
CONCEALED IN WALL. REFER TO
DETAIL 7/A700
REFER TO MILLWORK PLAN
TILE-2
QTZ-1
PLM-1
OVER
APPROPRIATE
SUBSTRATE
QTZ-1
SCALE:
SECTION AT STAFF LOCKERS
3/4"=1'-0"
MELAMINE INTERIOR
HINGE AND LOCK AS INDICATED
BLUM 98110 SELF CLOSING
FIXED DIVIDER
NAILER
NAILER
ADJUSTABLE SHELF ON 32MM SYSTEM
ON ELEVATIONS
SCALE:
SECTION AT RECEPTION DESK
1 1/2" = 1'-0"
34" X 34" X 18" STL. SUPPORT BRACKET
NOTE: PROVIDE WIRE MANAGEMENT
SYSTEM FOR POWER AND
COMMUNICATION LINES
212" X 3" X 18" STL. ANGLE SUPPORT
REFER TO MILLWORK PLAN
WALL CONSTRUCTED BY
FRAMER/DRYWALLER
PROVIDE STEEL TUBE SUPPORTS
CONCEALED IN WALL. REFER TO
DETAIL 7/A700
REFER TO MILLWORK PLAN
TILE-2
QTZ-1
PLM-1
OVER
APPROPRIATE
SUBSTRATE
12
11
05/10/18
A
A
W
WAITING
100
CHECK IN
102
ACCESSIBLE
105
CHECK IN
PANO
108
STERILE
116 CONSULT
106
STAFF
124
FIRE
123
RISER
OFFICE
103
PRIVATE
117
OP 6
PRIVATE
118
OP 7
TECHNOLOGY
120
OP 1
110
OP 2
111
OP 3
112
OP 4
113
OP 5
114
RESTROOM
101
RESTROOM
121
LAB
125
EQUIPMENT
122
HALLWAY
119
HALLWAY
115
HANDWASH
109
HALLWAY
104
HALLWAY
107
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
HPE BP
03/01/18
E1
POWER PLAN
SCALE: 1/4"=1'-0"
POWER PLAN1
N
SOLID = NEW. DASHED = EXISTING.
2 ELECTRICAL ONE LINE DIAGRAM
05/10/18
A
A
W
WAITING
100
CHECK IN
102
ACCESSIBLE
105
CHECK IN
PANO
108
STERILE
116 CONSULT
106
STAFF
124
FIRE
123
RISER
OFFICE
103
PRIVATE
117
OP 6
PRIVATE
118
OP 7
TECHNOLOGY
120
OP 1
110
OP 2
111
OP 3
112
OP 4
113
OP 5
114
RESTROOM
101
RESTROOM
121
LAB
125
EQUIPMENT
122
HALLWAY
119
HALLWAY
115
HANDWASH
109
HALLWAY
104
HALLWAY
107
bloom studio
13538 raritan way
suite 101
westminster, colorado 80234
720.328.1366
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET TITLE:
SHEET NUMBER:
EDV101
HPE BP
03/01/18
SCALE: 1/4"=1'-0"
LIGHTING PLAN 1
N
E2
LIGHTING PLAN
05/10/18
AIR DEVICE SCHEDULE
FAN SCHEDULE
TYPICAL DIFFUSER CONNECTION
M001
HVAC SCHEDULES
McDO
LIMITED TO HVAC AND PLUMBING
NOT ISSUED FOR CONSTRUCTION
UNLESS SIGNED THROUGH THE SEAL
IN BLUE INK OR DIGITALLY SIGNED BY
PETER F. McDONALD, PE
MCDONALD CONSULTING + DESIGN, INC.
MECHANICAL CONSULTING ENGINEERS
10698 AMESBURY WAY
HIGHLANDS RANCH, COLORADO 80126
P: 303.875.9293 E: peter@mcdonaldconsulting.us
A M D G
33310PETERFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMccccccccccccccccccDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDONALD 05/10/18
2
2
4
1 1
M101
FLOOR PLAN - HVAC
McDO
LIMITED TO HVAC AND PLUMBING
NOT ISSUED FOR CONSTRUCTION
UNLESS SIGNED THROUGH THE SEAL
IN BLUE INK OR DIGITALLY SIGNED BY
PETER F. McDONALD, PE
MCDONALD CONSULTING + DESIGN, INC.
MECHANICAL CONSULTING ENGINEERS
10698 AMESBURY WAY
HIGHLANDS RANCH, COLORADO 80126
P: 303.875.9293 E: peter@mcdonaldconsulting.us
A M D G
33310PETERFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMccccccccccccccccccDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDONALD 05/10/18
NOT ALL ITEMS LISTED BELOW ARE USED ON THIS SET OF DRAWINGS
MECHANICAL LEGEND
HS
HR
CHS
LPC
HPS
HPC
PC
CS
CHR
CR
LPS
FOS
FOR
FOV
RL
RS
RHG
D
DEMOLITION NOTES:
SHEET METAL GENERAL NOTES
PLUMBING GENERAL NOTES GENERAL NOTES:
MP001
MECHANICAL LEGEND &
GENERAL NOTES
McDO
LIMITED TO HVAC AND PLUMBING
NOT ISSUED FOR CONSTRUCTION
UNLESS SIGNED THROUGH THE SEAL
IN BLUE INK OR DIGITALLY SIGNED BY
PETER F. McDONALD, PE
MCDONALD CONSULTING + DESIGN, INC.
MECHANICAL CONSULTING ENGINEERS
10698 AMESBURY WAY
HIGHLANDS RANCH, COLORADO 80126
P: 303.875.9293 E: peter@mcdonaldconsulting.us
A M D G
33310PETERFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMccccccccccccccccccDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDONALD 05/10/18
MECHANICAL SPECIFICATIONS
MP002
MECHANICAL
SPECIFICATION
McDO
LIMITED TO HVAC AND PLUMBING
NOT ISSUED FOR CONSTRUCTION
UNLESS SIGNED THROUGH THE SEAL
IN BLUE INK OR DIGITALLY SIGNED BY
PETER F. McDONALD, PE
MCDONALD CONSULTING + DESIGN, INC.
MECHANICAL CONSULTING ENGINEERS
10698 AMESBURY WAY
HIGHLANDS RANCH, COLORADO 80126
P: 303.875.9293 E: peter@mcdonaldconsulting.us
A M D G
33310PETERFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMccccccccccccccccccDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDONALD 05/10/18
PLUMBING EQUIPMENT SCHEDULE
PLUMBING FIXTURE SCHEDULE
GENERAL SCHEDULE NOTES:
A.REFER TO ARCHITECTURAL DRAWINGS AND ELEVATIONS FOR EXACT LOCATION AND MOUNTING HEIGHT ELEVATIONS OF ALL PLUMBING FIXTURES PRIOR TO INSTALLATION
B.PROVIDE ALL FIXTURES WITH CHROME PLATED CAST BRASS, ADJUSTABLE 'P' TRAPS WITH CLEANOUT PLUGS, TUBING OUTLETS AND WALL FLANGES UNLESS FIXTURE IS FURNISHED WITH AN INTEGRAL TRAP OR IS
PROVIDED ONE AS A STANDARD ACCESSORY
C.PROVIDE ALL FIXTURES WITH CHROME PLATED SUPPLIES WITH ANGLE OR STRAIGHT PATTERN LOOSE KEY STOPS UNLESS FIXTURE IS FURNISHED WITH INTEGRAL STOPS OR STOPS ARE PROVIDED AS STANDARD
ACCESSORIES
D.ALL FLUSH VALVES SHALL HAVE A.D.A COMPLIANT HANDLES
E.ALL EXPOSED PIPING SHALL BE POLISHED CHROME
F.COORDINATE ALL CASEWORK MOUNTED FIXTURES WITH BASE CABINET DIMENSIONS PRIOR TO ORDERING FIXTURES. NOTIFY ARCHITECT/ENGINEER IMMEDIATELY IF A CONFLICT EXISTS
G.ACCESSIBLE WATER CLOSETS SHALL BE OPERABLE FROM THE WIDE SIDE OF THE STALL
SCHEDULE REMARKS: (NOT ALL REMARKS MAY BE APPLICABLE TO THIS PROJECT)
1.FIXTURE DESIGNATED TO BE IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT (A.D.A)
2.REFRIGERATION SYSTEM CHARGED WITH R-134A REFRIGERANT
3.FAUCET COMPLETE WITH RIGID GOOSENECK SPOUT, E3-VP AERATOR AND 317 WRIST BLADE HANDLES. INSULATE TRAP AND WATER SUPPLIES
4.EXTEND CHROME PLATED TAILPIECE TO PLASTER TRAP
5.FAUCET TO HAVE ROUGH CHROME FINISH AND SHALL BE MOUNTED 3'-6" A.F.F. PROVIDE MSG 2424 S.S. WALL GUARD AND VANDAL-PROOF DRAIN
6.FAUCET LEDGE SHALL BE PUNCHED FOR SINGLE HOLE FAUCET SPECIFIED
7.PROVIDE CHROME PLATED TAILPIECE EXTENSION AND TURN DOWN TO ALLOW FOR KNEE-SPACE CLEARANCE.
8.INSTALL DISPOSER IN RIGHT-HAND COMPARTMENT AND DRAIN STRAINER IN LEFT-HAND COMPARTMENT
9.ROUGH-IN AND CONNECT TO SINK BASIN FURNISHED AND INSTALLED BY CASEWORK SUPPLIER
10.MOUNT SHOWER HEAD AT 6'-0" A.F.F.
11.1.1 GALLONS PER FLUSH
12.0.5 GALLONS PER FLUSH
13.PROVIDE TAIL PIECE DRAIN CONNECTION FOR DRAIN FROM ULTASONIC CLEANER
14.PROVIDE KOHLER K-13601 THERMOSTATIC MIXING VALVE SET AT 90°F
15.REFER TO ARCHITECT FOR REQUIRED FIXTURE COLOR
16.PLASTER TRAP PROVIDED BY DENTAL EQUIPMENT VENDOR INSTALLED BY PLUMBING CONTRACTOR
17.PROVIDE GOOSE NECK FAUCET SPOUT ONLY CONTROL WITH TAPMASTER CABINET DOOR KNEE CONTROL
ELECTRIC WATER HEATER SCHEDULE
P001
PLUMBING SCHEDULES
McDO
LIMITED TO HVAC AND PLUMBING
NOT ISSUED FOR CONSTRUCTION
UNLESS SIGNED THROUGH THE SEAL
IN BLUE INK OR DIGITALLY SIGNED BY
PETER F. McDONALD, PE
MCDONALD CONSULTING + DESIGN, INC.
MECHANICAL CONSULTING ENGINEERS
10698 AMESBURY WAY
HIGHLANDS RANCH, COLORADO 80126
P: 303.875.9293 E: peter@mcdonaldconsulting.us
A M D G
33310PETERFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMccccccccccccccccccDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDONALD 05/10/18
WASTE AND VENT RISER DIAGRAM
TRAP PRIMERS SHALL BE INSTALLED ON ALL FLOOR DRAINS AND FLOOR SINKS
WALL CLEANOUT DETAIL
WCO
S-1
WCO
S-3
WCO
WC-1 2"FD-1 WCO
L-1
WCO
WC-1 2"FD-1 WCO
L-1
WCO
S-2
WCO
S-1
DW
3"FS-1 SH-1 MSB-1
ELECTRIC WATER HEATER DETAIL
- SUSPENDED FROM CEILING/ROOF
STRUCTURE ON UNISTRUT SUPPORTS
TRAP PRIMER DETAIL
2"FD-1
P002
PLUMBING DETAILS
McDO
LIMITED TO HVAC AND PLUMBING
NOT ISSUED FOR CONSTRUCTION
UNLESS SIGNED THROUGH THE SEAL
IN BLUE INK OR DIGITALLY SIGNED BY
PETER F. McDONALD, PE
MCDONALD CONSULTING + DESIGN, INC.
MECHANICAL CONSULTING ENGINEERS
10698 AMESBURY WAY
HIGHLANDS RANCH, COLORADO 80126
P: 303.875.9293 E: peter@mcdonaldconsulting.us
A M D G
33310PETERFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMccccccccccccccccccDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDONALD 05/10/18
1. CONNECT NEW SANITARY WASTE TO EXISTING 4" OR LARGER BUILDING DRAIN
LINE BELOW SLAB, VERIFY EXACT LOCATION, SIZE, DEPTH AND FLOW
DIRECTION OF EXISTING IN FIELD PRIOR TO START OF WORK
2. CONNECT NEW 212" VENT TO EXISTING 3" VENT STUB AT CEILING, VERIFY
LOCATION AND SIZE IN FIELD PRIOR TO START OF WORK
11 1
2
P101
FLOOR PLAN - PLUMBING
WASTE & VENT
McDO
LIMITED TO HVAC AND PLUMBING
NOT ISSUED FOR CONSTRUCTION
UNLESS SIGNED THROUGH THE SEAL
IN BLUE INK OR DIGITALLY SIGNED BY
PETER F. McDONALD, PE
MCDONALD CONSULTING + DESIGN, INC.
MECHANICAL CONSULTING ENGINEERS
10698 AMESBURY WAY
HIGHLANDS RANCH, COLORADO 80126
P: 303.875.9293 E: peter@mcdonaldconsulting.us
A M D G
33310PETERFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMccccccccccccccccccDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDONALD 05/10/18
1.CONNECT NEW 114" CW TO EXISTING CW AT CEILING, VERIFY EXACT
LOCATION AND SIZE IN FIELD PRIOR TO START OF WORK
2.MASTER SHUT-OFF VALVE COORDINATE EXACT LOCATION AND SHUT-OFF
VALVE REQUIREMENTS WITH DENTAL EQUIPMENT VENDOR PRIOR TO
ROUGH-IN
3.SUSPEND WATER HEATER FROM OVERHEAD STRUCTURE OVER MOP SINK
4. 12" CW DOWN TO CONNECTION AT VACUUM PUMP, PROVIDE SHUT-OFF VALVE
AND IN-LINE BACKFLOW PREVENTER AT CONNECTION
5. 12" CW DOWN IN WALL TO CONNECTION AT MODEL TRIMMER, PROVIDE
SHUT-OFF VALVE AND IN-LINE BACKFLOW PREVENTER AT CONNECTION
6. 12" CW DOWN IN WALL TO CONNECTION AT OWNER PROVIDED WATER
DISPENSER
4
2
1
5
3
6
P201
FLOOR PLAN - PLUMBING
WATER
McDO
LIMITED TO HVAC AND PLUMBING
NOT ISSUED FOR CONSTRUCTION
UNLESS SIGNED THROUGH THE SEAL
IN BLUE INK OR DIGITALLY SIGNED BY
PETER F. McDONALD, PE
MCDONALD CONSULTING + DESIGN, INC.
MECHANICAL CONSULTING ENGINEERS
10698 AMESBURY WAY
HIGHLANDS RANCH, COLORADO 80126
P: 303.875.9293 E: peter@mcdonaldconsulting.us
A M D G
33310PETERFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMccccccccccccccccccDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDONALD 05/10/18
1. 2" VAC, UP THROUGH FLOOR TO CONNECTION AT VACUUM PUMP, VERIFY
CONNECTION POINTS AND REQUIREMENTS WITH DENTAL EQUIPMENT VENDOR
PRIOR TO ROUGH-IN
2. 1" AIR DOWN IN WALL TO CONNECTION AT AIR COMPRESSOR, VERIFY
CONNECTION POINTS AND REQUIREMENTS WITH DENTAL EQUIPMENT VENDOR
PRIOR TO ROUGH-IN
3. 2" AIR INTAKE FROM AIR COMPRESSOR TO APPROVED WALL INTAKE CAP, VERIFY
CONNECTION REQUIREMENTS WITH DENTAL EQUIPMENT VENDOR PRIOR TO
ROUGH-IN
4. 2" VENT FROM VACUUM PUMP TO APPROVE WALL TERMINATION CAP, VERIFY
CONNECTION REQUIREMENTS WITH DENTAL EQUIPMENT VENDOR PRIOR TO
ROUGH-IN
5. 12" AIR DOWN IN WALL TO CONNECTION AT DENTAL EQUIPMENT PROVIDED BY
DENTAL EQUIPMENT VENDOR, VERIFY CONNECTION REQUIREMENTS WITH
DENTAL EQUIPMENT PRIOR TO ROUGH-IN
6. 12" AIR DOWN IN WALL TO CONNECTION AT DENTAL EQUIPMENT PROVIDED BY
DENTAL EQUIPMENT VENDOR, CONTINUE 12" AIR DOWN TO BELOW SLAB, ROUTE
BELOW SLAB TO CONNECTION AT CHAIR CONNECTION POINT, VERIFY
CONNECTION REQUIREMENTS WITH DENTAL EQUIPMENT PRIOR TO ROUGH-IN
7. 12" AIR DOWN IN WALL TO BELOW SLAB, ROUTE BELOW SLAB AS SHOWN TO
CONNECTION AT DENTAL EQUIPMENT
8. 12" AIR UP FROM BELOW SLAB TO CONNECTION AT DENTAL EQUIPMENT, WITH 12"
AIR BACK DOWN TO BELOW SLAB TO CONNECTION AT CHAIR TOE CONNECTION
POINT, VERIFY CONNECTION REQUIREMENTS WITH DENTAL EQUIPMENT PRIOR
TO ROUGH-IN
9. 2" VAC UP FROM BELOW SLAB WITH 2x34" REDUCER FOR CONNECTION TO
DENTAL EQUIPMENT, VERIFY CONNECTION POINT AND REQUIREMENTS WITH
DENTAL EQUIPMENT PRIOR TO ROUGH-IN
10. 12" AIR UP FROM BELOW SLAB TO CONNECTION AT DENTAL CHAIR, VERIFY
CONNECTION POINT AND REQUIREMENTS WITH DENTAL EQUIPMENT PRIOR TO
ROUGH-IN
VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VACVAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC VAC
VAC VAC VACVAC VAC VACA A A A A A A A A A AA A A A A A A A A A A A A A A A A AA
A A A A AA A A A A A A A A A A AA A A
AAAAAAAAAA A A A
AAA A A A
A A A A
A A A A
A A A A
A
AAAAAAA A4
1
2
3
7
7
7
9
9
9
9
910
10
10
10
10
5
5
5
9 6
1010
96
8
8
8
8
8
P301
FLOOR PLAN - PLUMBING
DENTAL PIPING
McDO
LIMITED TO HVAC AND PLUMBING
NOT ISSUED FOR CONSTRUCTION
UNLESS SIGNED THROUGH THE SEAL
IN BLUE INK OR DIGITALLY SIGNED BY
PETER F. McDONALD, PE
MCDONALD CONSULTING + DESIGN, INC.
MECHANICAL CONSULTING ENGINEERS
10698 AMESBURY WAY
HIGHLANDS RANCH, COLORADO 80126
P: 303.875.9293 E: peter@mcdonaldconsulting.us
A M D G
33310PETERFMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMccccccccccccccccccDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDONALD 05/10/18