Loading...
HomeMy WebLinkAboutB18-0097_Approved Plans_1529600453.pdfENTRY CLOSET BEDROOM BATHROOM ENTRY CLOSET BEDROOM BATHROOM ENTRYCLOSET BEDROOM BATHROOM 2.03 2.15 2.04 2.16 2.10 2.17 2.09 2.04 2.04 2.14 2.13 2.07 2.06 2.12 2.06 2.11 2.01 2.18 2.06 2.19 2.01 2.18 2.01 116 22.01 9.16 9.17 9.18 6.01 9.09 9.05 9.10 9.15 9.13 9.14 2.08 26.02 26.02 9.08 9.07 10.01 10.01 26.04 9.10 9.10 9.01 9.01 9.19 DEMO OBJECT EXISTING WALL DEMO PLAN LEGEND AREA NOT IN CONTRACT EXISTING WALL NEW WALL FLOOR PLAN LEGEND AREA NOT IN CONTRACT 9.15 26.01 9.06 26.01 9.06 26.01 9.06 26.05 26.05 26.05 26.06 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®3/28/2018 1:19:47 PM C:\Revit Local Files\116194.00_Four Seasons Vail__A17_GR and Corridor Permit Set_kadams.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/03/28 ISSUE FOR BUILDING PERMIT ROOM 5036 - DEMO PLAN, FLOOR PLAN, & RCP A-100A FOUR SEASONS RESORT AT VAIL OZ 1/4" = 1'-0"1 ROOM 5036 - DEMO PLAN 1/4" = 1'-0"2 ROOM 5036-FLOOR PLAN DEMOLITION PLAN NOTES 1 REFER TO "I" SERIES DRAWINGS FOR ALL FINISH INFORMATION, INCLUDING, BUT NOT LIMITED TO WALLS,FLOORS, CEILINGS, TRIM, DOORS, MILLWORK DETAILS, ACCESSORIES AND FF&E. 2 EXISTING INFORMATION SHOWN ON THE DRAWINGS IS BASED ON LIMITED FIELD OBSERVATIONS AND/OR INFORMATION PROVIDED BY THE OWNER. OZ ARCHITECTURE IS NOT RESPONSIBLE FOR THE ACCURACY OF INFORMATION OR THE ADEQUACY, SAFETY, AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. THE GC SHALL THOROUGHLY EXAMINE THE PREMISES AND SHALL BASE HIS BID ON THE EXISTING CONDITIONS NOT WITHSTANDING ANY INFORMATION SHOWN, OR NOT SHOWN, ON THE CONTRACT DOCUMENTS. SHOULD ANY DISCREPANCIES BE FOUND, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 3 THE GC SHALL MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE AND FIREPROOFING U.N.O. 4 IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING CONSTRUCTION, NOTIFY THE OWNER AND ARCHITECT IMMEDIATELY AND AWAIT FURTHER INSTRUCTIONS. 5 WORK TO BE REMOVED IS ILLUSTRATED IN DASHED LINE-WORK. EXISTING CONSTRUCTION TO REMAIN IS ILLUSTRATED IN LIGHT LINE-WORK. ALL ITEMS FOR REMOVAL MAY NOT BE SPECIFICALLY NOTED. REMOVE ITEMS AS NECESSARY FOR THE COMPLETION OF THE WORK. 6 SEE ENGINEERING DRAWINGS FOR THE REMOVAL OF SPECIFIC STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE ALARM SYSTEMS. 7 WHERE THE TERM "REMOVE" OR “DEMOLISH” IS USED, THE GC SHALL REMOVE ITEM FROM THE SITE AND LEGALLY DISPOSE OF. 8 WHERE THE TERM "SALVAGE" IS USED, THE GC SHALL REUSE THE ITEM ON THIS PROJECT OR RETURN TO THE OWNER. 9 WHERE THE TERM "REMOVE AND REINSTALL" IS USED, THE GC IS TO DETACH ITEM FROM EXISTING CONSTRUCTION, PREPARE AND CLEAN ITEM FOR REUSE, AND REINSTALL WHERE INDICATED. 10 WHERE THE TERM "EXISTING TO REMAIN" IS USED, THE EXISTING ITEMS ARE NOT TO BE REMOVED. PROTECT FROM DAMAGE AS REQUIRED. THE GC IS TO REPLACE OR REPAIR ITEMS DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 11 SALVAGE MECHANICAL EQUIPMENT, PLUMBING FIXTURES, DOORS AND FRAMES, CABINETS, AND LIGHT FIXTURES FOR REINSTALLATION. STORE SALVAGEABLE MATERIALS IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER MATERIAL AND DEBRIS SHALL BE DISPOSED OF BY THE GC. 12 WHERE MECHANICAL, ELECTRICAL, AND PLUMBING DEVICES ARE REMOVED, ABANDONED PIPING AND/OR CONDUITS SHALL BE CAPPED BELOW THE FLOOR, INSIDE THE PARTITION, OR ABOVE THE CEILING AND AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. UNUSED WIRING IS TO BE REMOVED BACK TO PANEL BOXES. PATCH AND REPAIR FINISHES AS REQUIRED TO MATCH SURROUNDING FINISHES. BLANK COVER PLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE U.N.O. 13 EXISTING CONCRETE SLAB DAMAGED DURING CONSTRUCTION SHALL BE PATCHED AND REPAIRED TO A CONDITION SUITABLE FOR NEW FINISHES. 14 PREPARE EXISTING WALLS FOR NEW FINISHES. REMOVE NAILS, PINS, TAPE, POSTERS, ETC.; FILL ALL HOLES; AND PREPARE SURFACES FOR PAINT OR WALLCOVERING. 15 REMOVE BASE IN AREAS WHERE FLOORING IS BEING REMOVED U.N.O. 16 PATCH AND REPAIR FLOOR AND PARTITION FINISHES WHERE INTERSECTING PARTITIONS HAVE BEEN REMOVED. MATCH ADJACENT SURFACE FOR FINISH, COLOR, AND TEXTURE. 17 COORDINATE UTILITY SHUT-DOWNS WITH BUILDING OWNER. 18 FOLLOW RECYCLING PROCEDURES FOR ITEMS TO BE REMOVED AS REQUIRED FOR LEED CERTIFICATION AND/OR BY THE AUTHORITY HAVING JURISDICTION. FLOOR PLAN NOTES 1 REFER TO "I" SERIES DRAWINGS FOR ALL FINISH INFORMATION, INCLUDING, BUT NOT LIMITED TO WALLS,FLOORS, CEILINGS, TRIM, DOORS, MILLWORK DETAILS, ACCESSORIES AND FF&E. 2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OF CONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOW U.N.O. 3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONS DESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED. 4 METAL STUD PARTITIONS ARE TYPE 23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O. 5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O. 6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OF PARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINT ASSEMBLIES. 7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE, THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGN U.N.O. 8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDE JAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENT PERPENDICULAR PARTITION. 9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THE FIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS IN ACCORDANCE WITH IBC CHAPTER 7. 10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION. 11 THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSED CONSTRUCTION. 12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK, MILLWORK AND OTHER BUILT-IN ITEMS. 13 REFER TO I-SERIES FOR ALL: ACCESSORIES, DIMENSIONS NOT SHOWN, MILLWORK DETAILS, FINISH SPECIFICATION INFORMATION 0' 1' 4' 8' 16'2' DOOR SCHEDULE 5036 DOOR NUMBER DOOR HARDWA RE SET NO. FRAME COMMENTS PANEL TYPE LEAF QUANTITY LEAF WIDTH OPENING WIDTH HEIGHT THICKNESS MATERIAL FINISH FRAME TYPE MATERIAL FINISH WALL THICK NESS HEAD JAMB 116 F 2 1' - 6" 3' - 0" 7' - 9" 1 3/4" WD RE: I-SERIES RE: I-SERIES RE: I-SERIES WD RE: I-SERIES 4 7/8" RE: I-SERIES RE: I-SERIES EXISTING OPENING - VERIFY ALL DIMENSIONS ON SITE NOTE: SEE I-SERIES SHEET I-10-702 FOR DOOR ELEVATIONS AND DETAILS. 1/4" = 1'-0" 3 ROOM 5036- RCP PROJECT FLAGNOTES NO. FLAGNOTE 2.01 REMOVE (E) CROWN TRIM AT CEILING 2.03 REMOVE (E) SCONCES. JBOX TO REMAIN 2.04 REMOVE (E) CEILING MOUNTED LIGHT FIXTURE 2.06 REMOVE (E) WALL COVERING 2.07 REMOVE (E) CARPET AND PAD 2.08 CLEAN AND REPAIR (E) STONE FLOOR AND WALLS 2.09 REMOVE (E) MINIBAR MILLWORK 2.10 REMOVE (E) CLOSET DOORS 2.11 REMOVE (E) WOOD FLOOR 2.12 REMOVE (E) CORNER WALL TRIM 2.13 REMOVE (E) STONE HEARTH, FIREPLACE FACE CLADDING, MANTLE AND TRIM ABOVE MANTLE 2.14 REMOVE (E) VALANCE AND DRAPERY TRACK 2.15 REMOVE (E) VANITY, SINKS, SCONCES AND MIRROR 2.16 REMOVE (E) SHOWERHEAD 2.17 REMOVE WALL HOOKS 2.18 REMOVE (E) DOOR HARDWARE 2.19 REMOVE (E) TOWEL RINGS AND GLASS VANITY SHELF 6.01 NEW DRYBAR MILLWORK, RE: I-SERIES 9.01 REFINISH (E) WALL BASE AND CASED OPENING THROUGHOUT. RE: I-SERIES FOR FINISH 9.05 NEW CARPET AND CARPET PAD THROUGHOUT. RE: I-SERIES FOR SPECIFICATION 9.06 PAINT CEILING THROUGHOUT, RE: I-SERIES FOR SPECIFICATION 9.07 REFINISH (E) CLOSET DOOR FRAME. RE: I-SERIES FOR FINISH 9.08 REFINISH (E) CLOSET MILLWORK. RE: I-SERIES FOR FINISH 9.09 NEW WOOD FLOOR. RE: I-SERIES FOR SPECIFICATION 9.10 NEW WALL COVERING. RE: I-SERIES FOR SPECIFICATION 9.13 RE-CLAD (E) FIREPLACE WITH NEW STONE FACE, STONE HEARTH AND WOOD MANTLE. RE: I-SERIES FOR SPECIFICATION 9.14 REFINISH DOOR AND WINDOW FRAMES BLACK. GC TO SUBMIT SAMPLE 9.15 NEW VALANCE AND DRAPERY TRACK. RE: I-SERIES FOR DETAILS AND SPECIFICATIONS 9.16 NEW VANITY AND SINK BASINS, (E) FAUCETS TO REMAIN. RE: PLUMBING AND I-SERIES 9.17 NEW FLOOR TRANSISTION RE: 2/I-12-702 9.18 NEW FLOOR TRANSISTION RE: 1/I-12-702 9.19 REFINISH (E) SLIDING DOOR & FRAME, RE: I-SERIES FOR FINISH 10.01 BATHROOM ACCESSORY LOCATIONS RE: I-SERIES 22.01 REPLACE (E) SHOWER HEAD. RE: PLUMBING & I-SERIES 26.01 NEW CEILING MOUNTED FIXTURE AT (E) JBOX LOCATION. RE: ELEC 26.02 NEW WALL SCONCE AT (E) J-BOX LOCATION 26.04 PROVIDE POWER FOR NEW ELECTRIC MIRROR 26.05 REPLACE (E) RECESSED LIGHTS, RE: ELEC & I-SERIES 26.06 NEW CLOSET LIGHT ABOVE DOOR, RE: ELEC & I-SERIES REFLECTED CEILING PLAN NOTES 1 REFLECTED CEILING PLANS INDICATE CEILING HEIGHTS AND LOCATION OF LIGHT FIXTURES, DIFFUSERS, DEVICES, AND SIMILAR ITEMS. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING ELECTRICAL, HVAC, SPRINKLER AND LIFE SAFETY. IN THE EVENT OF A DISCREPANCY BETWEEN THE ARCHITECT'S REFLECTED CEILING PLAN AND THE ENGINEERS' PLANS, SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 2 COORDINATE ALL TRADES INVOLVED IN THE CEILING WORK TO ENSURE CLEARANCE FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS, ETC. NECESSARY TO MAINTAIN THE CEILING HEIGHTS INDICATED. 3 DIMENSIONS ARE TO FINISH U.N.O. 4 ACCESS PANELS NOT SHOWN, BUT REQUIRED BY PLUMBING, MECHANICAL, OR ELECTRICAL SYSTEMS, SHALL BE REVIEWED WITH ARCHITECT FOR LOCATION. 5. COORDINATE LOCATION OF FIRE SPRINKLER HEADS WITH ARCHITECT. 6 LIGHT FIXTURES, SPRINKLER HEADS, AND OTHER CEILING DEVICES SHALL BE EQUALLY SPACED AND ALIGNED WITH ADJACENT ELEMENTS AND CENTERED ON CEILING TILE, U.N.O. 7 CENTER ACOUSTICAL CEILING GRID WITHIN THE ROOM U.N.O. 8 PAINT GYPSUM BOARD CEILINGS P__ U.N.O. 9 PAINT GYP BOARD SOFFITS (VERTICAL AND HORIZONTAL SURFACES) P__ U.N.O. 10 PAINT EXPOSED CEILING STRUCTURE AND DUCTWORK P__ U.N.O. 11 PROVIDE UL-CLASSIFIED LIGHT FIXTURES OR ENCLOSURES IN RATED FLOOR/CEILING ASSEMBLIES IN ACCORDANCE WITH IBC CHAPTER 7. Provide a hardwired battery backup smoke detector and a Carbon Monoxide detector. Provide the fireplace intall manual to confirm required clearance to combutible mantle. 06/21/18 2.20 2.04 2.05 2.03 2.02 2.02 2.02 2.02 2.01 2.06 2.07 9.01 9.03 9.02 9.04 9.05 DEMO OBJECT EXISTING WALL DEMO PLAN LEGEND AREA NOT IN CONTRACT EXISTING WALL NEW WALL FLOOR PLAN LEGEND AREA NOT IN CONTRACT 2.0526.05 26.01 26.03 26.02 9.06 9.06 9.06 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®3/28/2018 1:19:50 PM C:\Revit Local Files\116194.00_Four Seasons Vail__A17_GR and Corridor Permit Set_kadams.rvt 1/8"= 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/03/28 ISSUE FOR BUILDING PERMIT MODEL CORRIDOR - DEMO PLAN, FLOOR PLAN + REFLECTED CEILING PLAN 5036 A-102A FOUR SEASONS RESORT AT VAIL OZ 1/8" = 1'-0"1 CORRIDOR - DEMO PLAN 1/8" = 1'-0"2 CORRIDOR - FLOOR PLAN 0' 1' 4' 8' 16'2' DEMOLITION PLAN NOTES 1 REFER TO "I" SERIES DRAWINGS FOR ALL FINISH INFORMATION, INCLUDING, BUT NOT LIMITED TO WALLS,FLOORS, CEILINGS, TRIM, DOORS, MILLWORK DETAILS, ACCESSORIES AND FF&E. 2 EXISTING INFORMATION SHOWN ON THE DRAWINGS IS BASED ON LIMITED FIELD OBSERVATIONS AND/OR INFORMATION PROVIDED BY THE OWNER. OZ ARCHITECTURE IS NOT RESPONSIBLE FOR THE ACCURACY OF INFORMATION OR THE ADEQUACY, SAFETY, AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. THE GC SHALL THOROUGHLY EXAMINE THE PREMISES AND SHALL BASE HIS BID ON THE EXISTING CONDITIONS NOT WITHSTANDING ANY INFORMATION SHOWN, OR NOT SHOWN, ON THE CONTRACT DOCUMENTS. SHOULD ANY DISCREPANCIES BE FOUND, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 3 THE GC SHALL MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE AND FIREPROOFING U.N.O. 4 IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING CONSTRUCTION, NOTIFY THE OWNER AND ARCHITECT IMMEDIATELY AND AWAIT FURTHER INSTRUCTIONS. 5 WORK TO BE REMOVED IS ILLUSTRATED IN DASHED LINE-WORK. EXISTING CONSTRUCTION TO REMAIN IS ILLUSTRATED IN LIGHT LINE-WORK. ALL ITEMS FOR REMOVAL MAY NOT BE SPECIFICALLY NOTED. REMOVE ITEMS AS NECESSARY FOR THE COMPLETION OF THE WORK. 6 SEE ENGINEERING DRAWINGS FOR THE REMOVAL OF SPECIFIC STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE ALARM SYSTEMS. 7 WHERE THE TERM "REMOVE" OR “DEMOLISH” IS USED, THE GC SHALL REMOVE ITEM FROM THE SITE AND LEGALLY DISPOSE OF. 8 WHERE THE TERM "SALVAGE" IS USED, THE GC SHALL REUSE THE ITEM ON THIS PROJECT OR RETURN TO THE OWNER. 9 WHERE THE TERM "REMOVE AND REINSTALL" IS USED, THE GC IS TO DETACH ITEM FROM EXISTING CONSTRUCTION, PREPARE AND CLEAN ITEM FOR REUSE, AND REINSTALL WHERE INDICATED. 10 WHERE THE TERM "EXISTING TO REMAIN" IS USED, THE EXISTING ITEMS ARE NOT TO BE REMOVED. PROTECT FROM DAMAGE AS REQUIRED. THE GC IS TO REPLACE OR REPAIR ITEMS DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 11 SALVAGE MECHANICAL EQUIPMENT, PLUMBING FIXTURES, DOORS AND FRAMES, CABINETS, AND LIGHT FIXTURES FOR REINSTALLATION. STORE SALVAGEABLE MATERIALS IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER MATERIAL AND DEBRIS SHALL BE DISPOSED OF BY THE GC. 12 WHERE MECHANICAL, ELECTRICAL, AND PLUMBING DEVICES ARE REMOVED, ABANDONED PIPING AND/OR CONDUITS SHALL BE CAPPED BELOW THE FLOOR, INSIDE THE PARTITION, OR ABOVE THE CEILING AND AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. UNUSED WIRING IS TO BE REMOVED BACK TO PANEL BOXES. PATCH AND REPAIR FINISHES AS REQUIRED TO MATCH SURROUNDING FINISHES. BLANK COVER PLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE U.N.O. 13 EXISTING CONCRETE SLAB DAMAGED DURING CONSTRUCTION SHALL BE PATCHED AND REPAIRED TO A CONDITION SUITABLE FOR NEW FINISHES. 14 PREPARE EXISTING WALLS FOR NEW FINISHES. REMOVE NAILS, PINS, TAPE, POSTERS, ETC.; FILL ALL HOLES; AND PREPARE SURFACES FOR PAINT OR WALLCOVERING. 15 REMOVE BASE IN AREAS WHERE FLOORING IS BEING REMOVED U.N.O. 16 PATCH AND REPAIR FLOOR AND PARTITION FINISHES WHERE INTERSECTING PARTITIONS HAVE BEEN REMOVED. MATCH ADJACENT SURFACE FOR FINISH, COLOR, AND TEXTURE. 17 COORDINATE UTILITY SHUT-DOWNS WITH BUILDING OWNER. 18 FOLLOW RECYCLING PROCEDURES FOR ITEMS TO BE REMOVED AS REQUIRED FOR LEED CERTIFICATION AND/OR BY THE AUTHORITY HAVING JURISDICTION. FLOOR PLAN NOTES 1 REFER TO "I" SERIES DRAWINGS FOR ALL FINISH INFORMATION, INCLUDING, BUT NOT LIMITED TO WALLS,FLOORS, CEILINGS, TRIM, DOORS, MILLWORK DETAILS, ACCESSORIES AND FF&E. 2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OF CONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOW U.N.O. 3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONS DESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED. 4 METAL STUD PARTITIONS ARE TYPE 23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O. 5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O. 6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OF PARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINT ASSEMBLIES. 7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE, THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGN U.N.O. 8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDE JAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENT PERPENDICULAR PARTITION. 9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THE FIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS IN ACCORDANCE WITH IBC CHAPTER 7. 10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION. 11 THERE SHALL BE NO EXPOSED PIPES, DUCTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED UNLESS SPECIFICALLY NOTED AS EXPOSED CONSTRUCTION. 12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK, MILLWORK AND OTHER BUILT-IN ITEMS. 13 REFER TO I-SERIES FOR ALL: ACCESSORIES, DIMENSIONS NOT SHOWN, MILLWORK DETAILS, FINISH SPECIFICATION INFORMATION 1/8" = 1'-0"3 CORRIDOR - RCP REFLECTED CEILING PLAN NOTES 1 REFLECTED CEILING PLANS INDICATE CEILING HEIGHTS AND LOCATION OF LIGHT FIXTURES, DIFFUSERS, DEVICES, AND SIMILAR ITEMS. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING ELECTRICAL, HVAC, SPRINKLER AND LIFE SAFETY. IN THE EVENT OF A DISCREPANCY BETWEEN THE ARCHITECT'S REFLECTED CEILING PLAN AND THE ENGINEERS' PLANS, SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 2 COORDINATE ALL TRADES INVOLVED IN THE CEILING WORK TO ENSURE CLEARANCE FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS, ETC. NECESSARY TO MAINTAIN THE CEILING HEIGHTS INDICATED. 3 DIMENSIONS ARE TO FINISH U.N.O. 4 ACCESS PANELS NOT SHOWN, BUT REQUIRED BY PLUMBING, MECHANICAL, OR ELECTRICAL SYSTEMS, SHALL BE REVIEWED WITH ARCHITECT FOR LOCATION. 5. COORDINATE LOCATION OF FIRE SPRINKLER HEADS WITH ARCHITECT. 6 LIGHT FIXTURES, SPRINKLER HEADS, AND OTHER CEILING DEVICES SHALL BE EQUALLY SPACED AND ALIGNED WITH ADJACENT ELEMENTS AND CENTERED ON CEILING TILE, U.N.O. 7 CENTER ACOUSTICAL CEILING GRID WITHIN THE ROOM U.N.O. 8 PAINT GYPSUM BOARD CEILINGS P__ U.N.O. 9 PAINT GYP BOARD SOFFITS (VERTICAL AND HORIZONTAL SURFACES) P__ U.N.O. 10 PAINT EXPOSED CEILING STRUCTURE AND DUCTWORK P__ U.N.O. 11 PROVIDE UL-CLASSIFIED LIGHT FIXTURES OR ENCLOSURES IN RATED FLOOR/CEILING ASSEMBLIES IN ACCORDANCE WITH IBC CHAPTER 7. PROJECT FLAGNOTES NO. FLAGNOTE 2.01 REMOVE (E) CROWN TRIM AT CEILING 2.02 REMOVE (E) LIGHTING FIXTURES. PATCH AND REPAIR CEILING 2.03 REMOVE (E) SCONCES. JBOX TO REMAIN 2.04 REMOVE (E) CEILING MOUNTED LIGHT FIXTURE 2.05 (E) RECESSED LIGHTS TO REMAIN 2.06 REMOVE (E) WALL COVERING 2.07 REMOVE (E) CARPET AND PAD 2.20 REMOVE & REPLACE (E) RECESSED LIGHTING FIXTURES, RE: ELEC. 9.01 REFINISH (E) WALL BASE AND CASED OPENING THROUGHOUT. RE: I-SERIES FOR FINISH 9.02 REFINISH (E) DOORS AND FRAMES THROUGHOUT. RE: I-SERIES FOR FINISH 9.03 INSTALL NEW WOOD ACCENT TRIM AT WALLS. RE: I-SERIES INTERIOR ELEVATIONS FOR SPECIFICATION AND LOCATION 9.04 NEW WALL COVERING THROUGHOUT. RE: I-SERIES FOR SPECIFICATION 9.05 NEW CARPET AND CARPET PAD THROUGHOUT. RE: I-SERIES FOR SPECIFICATION 9.06 PAINT CEILING THROUGHOUT, RE: I-SERIES FOR SPECIFICATION 26.01 NEW CEILING MOUNTED FIXTURE AT (E) JBOX LOCATION. RE: ELEC 26.02 NEW WALL SCONCE AT (E) J-BOX LOCATION 26.03 REPLACE TRIM AT (E) FIXTURE. W/ WALL WASH DIRECTIONAL TRIM 26.05 REPLACE (E) RECESSED LIGHTS, RE: ELEC & I-SERIES 06/21/18 ' ' ISSUE LOG KEY: # DATEISSUE LOG ELECTRICAL SHEET INDEX TITLE ELECTRICAL COVER SHEETE-000 PERMIT SET08.02.2017ISSUED AS PART OF A SET ' ' NOT PART OF SET ' ' ISSUED FOR INFORMATION ONLY* √ √ √ √ ELECTRICAL SPECIFICATIONSE-001 ROOM 5036 ELECTRICAL PLANSE-100 GFCI DUPLEX RECEPTACLE DUPLEX RECEPTACLE; HALF SWITCHED ISOLATED GROUND DUPLEX RECEPTACLE WALL MOUNTED SPECIAL OUTLET AS NOTED SPECIAL OUTLET AS NOTED JUNCTION BOX WALL MOUNTED JUNCTION BOX FLOOR MOUNTED JUNCTION BOX DUPLEX RECEPTACLE MOUNTED ABOVE COUNTERC FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM DIVISION 15 EQUIPMENT POWER CONNECTION FUSED DISCONNECT NON FUSED DISCONNECT MOTOR STARTER ENCLOSED CIRCUIT BREAKER PULL BOX PUSH BUTTON TRANSFORMER PANELBOARD OR LOADCENTER CONTACTOR ELECTRIC MOTOR METER THERMOSTAT ATS AUTOMATIC TRANSFER SWITCH ONE-LINE DIAGRAM SYMBOLS CIRCUIT HOMERUN CONDUIT RUN CONDUIT RUN BELOW GRADE CONDUIT UP CONDUIT DOWN DISCONNECT SWITCH FUSE CIRCUIT BREAKER CURRENT TRANSFORMER POTENTIAL TRANSFORMER METER SURGE SUPPRESSION DEVICE VOLT-METER SELECTOR SWITCH GROUND GF GROUND FAULT PROTECTION AMP-METER ST SHUNT TRIP NORMALLY OPEN CONTACT NORMALLY CLOSED CONTACT COLD WATER GROUND CONNECTION BUILDING STEEL GROUND CONNECTION TIMER SWITCH MULTI-OUTLET PLUG STRIP TIME CLOCK PHOTO-CELL SWITCH THERMAL OVERLOAD SWITCH VARIABLE SPEED SWITCH KEY SWITCH LIGHTING FIXTURE SYMBOLS RECESSED LIGHTING FIXTURE WALL MOUNTED LIGHT WALL MOUNTED UP-LIGHT PENDANT MOUNTED LIGHT SURFACE MOUNTED LIGHT DIRECTIONAL/ADJUSTABLE RECESSED LIGHTING FIXTURE MONO-POINT LIGHTING FIXTURE RECESSED STEP LIGHT FLUORESCENT STRIP LIGHT WALL MOUNTED LINEAR FLUORESCENT LIGHT RECESSED OR SURFACE MOUNTED FLUORESCENT TROFFER FIXTURE WITH EMERGENCY BACKUP OR ON EM CIRCUIT WALL MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN EMERGENCY LIGHTS CEILING MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH DOOR JAMB SWITCH LIGHTING CONTROL SYMBOLS EXTERIOR POLE MOUNTED LIGHT EXTERIOR POST (BOLLARD) MOUNTED LIGHT DAYLIGHT PHOTO SENSORDL KEY SWITCH LV VARIABLE SPEED SWITCH DIMMER THREE-WAY DIMMER LOW VOLTAGE SWITCH WALL OCCUPANCY SENSOR/SWITCH THERMAL OVERLOAD SWITCH OCCUPANCY SENSOR - WALL MOUNTED OCCUPANCY SENSOR - CORRIDOR CEILING MOUNTED S S3 ST SO D 3 D SV SK SJ S4 SK SV ST S PC TC TS A V SS M T C T PB CB N -- J J J ABBREVIATIONSPOWER SYMBOLS SINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE NOTE: ALL SYMBOLS SHOWN ON LEGEND ARE NOT NECESSARILY USED. OS OS OCCUPANCY SENSOR - CEILING MOUNTED OS NOTES: · LIGHT LINEWEIGHT INDICATES EXISTING. · HATCHED AREAS INDICATE DEMOLITION. · 'C' ADJACENT TO A DEVICE INDICATES MOUNTING ABOVE COUNTERTOP. AFC AFF AFG AHJ - ABOVE FINISHED CEILING - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE - AUTHORITY HAVING JURISDICTION AL - ALUMINUM AWG AP - ACCESS POINT - AMERICAN WIRE GAUGE BFG BMS BAS - BUILDING AUTOMATION SYSTEM - BELOW FINISH GRADE - BUILDING MANAGEMENT SYSTEM C CATV CCTV - CONDUIT - COMMUNITY (CABLE) ANTENNA TELEVISION SYSTEM - CLOSED CIRCUIT TELEVISION CKT - CIRCUIT CPU - CENTRAL PROCESSING UNIT CT - CURRENT TRANSFORMER DISP - GARBAGE DISPOSAL DW - DISHWASHER (E) - EXISTING EM - EMERGENCY EWC - ELECTRIC WATER COOLER FBO GFI FA FACP GRD GC - FIRE ALARM - FIRE ALARM CONTROL PANEL - FURNISHED BY OTHERS - GENERAL CONTRACTOR - GROUND FAULT CIRCUIT INTERRUPTER - GROUND IAW IN ACCORDANCE WITH- IC IDF IG IR LAN - INTERMEDIATE CROSS-CONNECT - INTERMEDIATE DISTRIBUTION FRAME - ISOLATED GROUND - INFRARED - LOCAL AREA NETWORK NIC MDF (N) MAIN DISTRIBUTION FRAME- NEW- NOT IN CONTRACT- NL NIGHT LIGHT- NTS NOT TO SCALE- OC PA ON CENTER- PUBLIC ADDRESS- REF REFRIGERATOR- TVSS TTB TELECOMMUNICATIONS TERMINAL BOARD- TRANSIENT VOLTAGE SURGE SUPPRESSOR- TVTB TELEVISION TERMINAL BOARD- UG UNO W V UNDERGROUND- UNLESS NOTED OTHERWISE- VOLT- WATT- WP XP WAN WLAN WAP WIDE AREA NETWORK- WIRELESS ACCESS POINT- WIRELESS LOCAL AREA NETWORK- WEATHERPROOF- EXPLOSIONPROOF- +18" DEVICE ABOVE FINISH FLOOR (VERIFY W/ ARCH ELEVS) MOUNTING HEIGHT TO CENTERLINE OF- ELECTRICAL SYSTEMS LEGEND L ELECTRONIC SAFETY & SECURITY SYMBOLS CEILING MOUNTED CAMERA WALL MOUNTED CAMERA MAGNETIC DOOR CONTACT SWITCH INTRUSION MOTION SENSOR LIGHTING CONTROL KEYPAD - LOW VOLTAGE MON CCTV MONITOR NVR NETWROK VIDEO RECORDER APS AUXILIARY POWER SUPPLY ACCESS CONTROL MAIN PANELACP EXIT PANIC/CRASH BAR SENSORREX SECURITY CENTRAL PROCESSING UNITCPU SECURITY/ACCESS CONTROL WORKSTATIONWS ADA ACCESS CONTROL MAIN PANELADA CRP CARD READER S ELECTRIC LOCK LR ELECTRIC LATCH / ROD RETRACTOR SM MAGNETIC DOOR CONTACT SWITCH K I PANIC BUTTONP (S = STRIKE, M = MAGNETIC) (P = PROXIMITY, S = SWIPE) TELEVISION OUTLET - FLOORBOX AUDIOVISUAL OUTLET - CEILING MOUNTED AUDIOVISUAL OUTLET - WALL MOUNTED AUDIOVISUAL OUTLET - FLOORBOX AV AV TELEVISON OUTLET - CEILING MOUNTED TELEVISION OUTLET - WALL MOUNTED LOUDSPEAKER - CEILING MOUNTED LOUDSPEAKER - WALL MOUNTED AUDIOVISUAL SYMBOLS SPEAKER ZONE HOMERUN VIDEO PROJECTOR TV AV PROJECTION SCREEN, TELEVISION, OR OTHER DISPLAY EQPT S S TV TV LOUDSPEAKER BAR - LEFT/CENTER/RIGHT LOUDSPEAKER BAR - STEREO LOUDSPEAKER - POWERED SUBWOOFER LOUDSPEAKER BAR - CENTER CHANNELCTR LR LCR S VOICE/DATA SYMBOLS COMBO PHONE/DATA OUTLET TELEPHONE WALL OUTLET DATA WALL OUTLET TELEPHONE FLOOR OUTLET DATA FLOOR OUTLET COMBO PHONE/DATA FLOOR OUTLET DOUBLE TELEPHONE WALL OUTLET DATA WALL OUTLET DOUBLE COMBO PHONE/DATA OUTLET PUBLIC PAYPHONE OUTLETPP ELEVATOR PHONE OUTLETE WIRELESS LAN (WI-FI) ACCESS POINT OUTLET FAX/COPIER OUTLET EMERGENCY SERVICES PHONE OUTLETEM F C √MODEL CORRIDOR ELECTRICAL PLANSE-102 √ROOM 5036 LIGHTING PLANEL-100 √MODEL CORRIDOR LIGHTING PLANEL-102 √ELECTRICAL DIAGRAMSE-300 √ELECTRICAL SCHEDULESE-002 GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK. 2. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. 3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER - IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. 4. SERVICE SHALL BE MAINTAINED TO EXISTING AREAS DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE PORTABLE GENERATORS, CABLES, OUTLETS, ETC. AS REQUIRED TO MAINTAIN CONTINUITY OF SERVICE. PLACEMENT OF SUCH PORTABLE EQUIPMENT SHALL BE SUBJECT TO OWNER APPROVAL. 5. REVIEW ARCHITECTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID. 6. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 7. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND ORDINANCES. 8. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 9. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS. 10. EXISTING SYSTEMS AND CONDITIONS SHOWN ON DRAWINGS FOR EXISTING BUILDINGS ARE TO BE NOTED “FOR GUIDANCE ONLY”. THE ELECTRICAL CONTRACTOR TO FIELD CHECK ALL EXISTING CONDITIONS PRIOR TO BIDDING AND TO INCLUDE IN HIS BID AN ALLOWANCE FOR REMOVAL AND/OR RELOCATION OF EXISTING CONDUITS, WIRES, DEVICES, FIXTURES, OR OTHER EQUIPMENT AS INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL SYSTEM TO ALL OTHER WORK AS REQUIRED 11. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL AND ELECTRICAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. 12. PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED CONDUIT, WIRE, CABLE, J-BOXES, RECEPTACLES, SWITCHES, LIGHTS, FIRE ALARMS DEVICES, ETC. COMPLETE WITH ASSOCIATED CIRCUITING TO SOURCE. WHERE IT IS NOT FEASIBLE TO REMOVE THE ABOVE, OUTLET SHALL BE ABANDONED, WIRE REMOVED, AND BLANK COVER PLATES PROVIDED. 13. ALL (E) EQUIPMENT, LAMPS, BALLASTS, ETC. BEING REMOVED SHALL BE DISCARDED IN ACCORDANCE WITH APPLICABLE EPA REQUIREMENTS. 14. EXISTING LIGHT FIXTURES, ELECTRICAL EQUIPMENT, ETC. BEING REMOVED SHALL BE RETURNED TO THE OWNER, EXCEPT FOR THOSE ITEMS BEING RELOCATED. 15. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN. 16. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION. 17. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED. 18. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 19. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. 20. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 20 AMPERES FOR DUPLEX RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT. 21. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS, UNLESS NOTED OTHERWISE. CONNECTORS SHALL BE INSULATED THROAT TYPE. MINIMUM RACEWAY SIZE IS 3/4”. ALL FEEDERS SHALL BE INSTALLED IN RACEWAY CONFIGURATIONS SHOWN ON ONE-LINE. BRANCH CIRCUITS 25A AND LARGER SHALL BE INSTALLED IN INDIVIDUAL RACEWAYS. BRANCH CIRCUITS 20A AND SMALLER MAY BE GROUPED INTO RACEWAYS AS TO NOT EXCEED 6 CURRENT-CARRYING 75-DEGREE CONDUCTORS, OR 9 CURRENT-CARRYING 90-DEGREE CONDUCTORS, IN A SINGLE RACEWAY. METAL CLAD CABLE IS NOT PERMITTED. 22. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUAL, AND SHALL BE IDENTIFIED AT ALL JUNCTION, PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT, ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. 23. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. 24. PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT. 25. PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS. 26. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVED FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT. 27. FIRE ALARM, SOUND, TELEPHONE, COMPUTER AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1” SHALL HAVE LONG RADIUS SWEEPS (12 TIMES THE DIAMETER). 28. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER. 29. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 30. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE.ISSUE FOR BUILDING PERMIT03.28.2018√ √ √ √ √ √ √ √ PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® As indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 816578203.11 2018/03/28 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\HOTEL ROOM CORRIDOR\8203.11E000.DWG03.27.1810:10:15 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 2 REVISION 2 3 REVISION 3 ELECTRICAL COVER SHEET E-000 BAS MAS MAS 06/21/18 ELECTRICAL SPECIFICATIONS: DIVISION 26 - ELECTRICAL SPECIFICATIONS SECTION 26 00 10 - GENERAL PROVISIONS PART 1 - GENERAL 1.01 PROJECT DESCRIPTION A.This project is a remodel and addition of a commercial building. The project is approximately 1,800 square feet located at One Vail Road in Vail, Colorado. 1.02 PROVISIONS A.Work performed under this division of the specifications shall conform to the requirements of Division 1, and the electrical drawings and all items hereinafter specified. 1.The drawings and specifications for the electrical work are intended to describe a complete electrical system; omission of minor items obviously necessary to accomplish the above intent shall not relieve the Contractor from providing same. 2.Prior to any work being performed under this division examine architectural, mechanical, and interior design drawings and specifications and if any discrepancies occur between them and the electrical drawings and specifications, report same to the Architect in writing and obtain written instructions for the work. 3.Electrical drawings are diagrammatic but shall be followed as closely as actual construction of the building will permit. All changes from drawings necessary to make the electrical work conform to the building as constructed shall be made without cost to the Owner. 4.Coordinate the electrical work with the General Contractor and be responsible to him for satisfactory progress of same. Coordinate electrical work with all other trades on the project without cost to the Owner. 5.Do not scale drawings. Verify dimensions on architectural drawings and in field prior to commencement of work. 6.All work and materials covered by drawings and specifications shall be subject to review at any time by representatives of the Architect and Owner. If the Architect or Owner's agent finds any material or installation that does not conform to these drawings and specifications, Contractor shall remove the material from the premises and correct the installation to the satisfaction of the agent. 7.In acceptance or rejection of installed electrical systems, no allowance will be made for lack of skill on the part of the installers. 1.03 WORK INCLUDED A.The electrical system required for this work to include, but is not necessarily limited to: 1.Complete branch circuit wiring for lighting, receptacles, junction boxes, and similar uses. 2.Lighting fixtures, wall switches, receptacles and similar items. 3.Lighting control system. 4.Wiring and outlets for data system. 5.Fire alarm system as required by national, state, and local codes. 6.Prewire for door/chime/intercom system as required. Coordinate with Owner and Architect. 7.Electrical requirements for fireplace, if applicable. 8.Power Owner furnished equipment. 1.04 CODES AND STANDARDS A.The applicable and enforced editions of the following Codes and published standards (including supplements and official interpretations) are minimum requirements: 1.NFPA 70 - National Electrical Code (NEC). 2.NFPA 72 - National Fire Alarm Code. 3.NFPA 101 - Life Safety Code. 4.NFPA 110 - Emergency Power Systems 5.Conform to all applicable State and Local Codes. 6.American National Standards Institute (ANSI). 7.National Electrical Safety Code (NESC). 8.Americans with Disabilities Acts (ADA) and American National Standards Institute (ANSI) 117. 9.National Electrical Manufacturer's Association (NEMA). 10.Underwriter's Laboratories (UL). 11.Insulated Cable Engineers Association (ICEA). 12.International Building Code. 13.International Mechanical Code. 14.International Fire Code. 15.Institute of Electrical and Electronic Engineers (IEEE). 16.Sheet Metal and Air Conditioning Contractors National Association (SMACNA). B.Comply with requirements of Underwriters Laboratories for all items installed for which U.L. standards have been established. C.The drawings and specifications take precedence when they are more stringent than codes, statutes, or ordinances in effect. Applicable codes, ordinances, standards and statutes take precedence when they are more stringent or conflict with the drawings and specifications. 1.05 EXAMINATION OF BIDDING DOCUMENTS A.Each bidder shall examine the bidding documents carefully, and not later than seven days prior to the date of receipt of bids, shall make written request to the Architect for interpretation or correction of any discrepancies, ambiguities, inconsistencies, or errors therein which he may discover. The Architect will issue any interpretation or correction as an Addendum. Only a written interpretation or correction by addendum shall be binding. No bidder shall rely upon interpretations or corrections given by any other method. If discrepancies, ambiguities, inconsistencies, or errors are not covered by addendum or written directive, Contractor shall include in his bid, labor, materials and methods of construction resulting in higher cost. After award of contract, no allowance or extra compensation will be made on behalf of the Contractor due to his failure to make the written requests as described above. B.Failure to request clarification during the bid phase of any inadequacy, omission, or conflict will not relieve the Contractor of their responsibilities. The signing of the contract will be considered as implicitly denoting that the Contractor has a thorough comprehension of the full intent and scope of the working drawings and specifications. 1.06 EXAMINATION OF PREMISES A.Visit site prior to bid and verify that conditions are as indicated. Contractor shall include in his bid costs required to make his work meet existing conditions. 1.07 EXISTING CONDITIONS A.Existing systems and conditions shown on drawings for existing buildings are to be noted "for guidance only". The Electrical Contractor shall field check all existing conditions prior to bidding and is to include in his bid an allowance for extension, removal and/or relocation of existing conduits, wires, devices, fixtures, or other equipment as indicated on the plans or as required to coordinate and adapt new and existing electrical system to all other work. B.Where the reuse of existing conduits, wires, devices, etc. is permissible, make certain that the wiring for same is continuous from outlet to outlet and that such circuit or systems shall pass through no outlet or junction boxes which may be rendered inaccessible by the structural changes to be made to the building. Existing conduits, wire, devices, etc. which are not indicated for reuse shall become the property of this Contractor however lighting fixtures, panel fused switches, circuit breakers, fire alarm equipment, etc. shall become the property of the Owner. C.System outages shall be permitted only at times approved by Owner in writing. Work which could result in an accidental outage (beyond branch circuits) shall be performed with the Owner's maintenance personnel advised of such work. D.Service shall be maintained to existing areas during construction. Contractor shall provide portable generators, cables, outlets, etc. as required to maintain continuity of service. Placement of such portable equipment shall be subject to Owner approval. Generator system shall be complete and operable and shall include required accessories, fuel tanks, piping, muffler, block heater, battery charger, etc. E.Immediately after award of contract, verify available physical space and ampacity of existing panelboards, switchboards, distribution boards, motor control centers, etc., and provide written documentation of findings to the Architect/Engineer. Documentation shall include a minimum 24-hour recording ampere reading on all existing switchgear being utilized for this project. F.Provide new updated panelboard directories for existing and new circuits being utilized for completion of project. 1.08 PERMITS, FEES & NOTICES A.Obtain and pay for all necessary permits, inspections and certificates that may be necessary for the full completion of the work. Furnish the Architect with a certificate of final inspection and approval from the AHJ over the electrical installation. B.Notify proper authorities when work is ready for inspections required by applicable codes, rules and regulations, allowing sufficient time for inspections to be made without hindering progress of the work. Furnish to the Owner copies of inspection certificates of acceptance. 1.09 TESTS A.Upon completion of all work and adjustment of all equipment, provide complete operational tests of all electrical equipment provided under this division. 1.10 WARRANTY A.Guarantee that all work governed by this division shall be free of defects in workmanship, materials and parts for a period of one (1) year after written acceptance. Promptly repair, revise, and replace defects as directed with no additional cost to the Owner (lamps and fuses are exempt). 1.11 RECORD DRAWINGS A.During the progress of the work, maintain an accurate record of the installation of the electrical system. Upon completion of the electrical installation, transfer all record data to prints of the original drawings. Drawings shall include all addendum items, change orders, alternates, reroutings, etc. As a condition of acceptance of the project, deliver to the Architect one copy of the record drawings. 1.12 PROTECTION A.Of People: Arrange barriers, signs, etc. as required to minimize the hazard of people. Comply with applicable safety and health regulations. Coordinate as necessary with the Owner and the General Contractor. B.Of Work: Take all measures necessary to protect the work both before and after installation, to assure that it will be in clean, undamaged, unblemished condition when turned over to the Owner. Repair/replace work damaged during construction. PART 2 - PRODUCTS 2.01 STANDARD FOR MATERIALS A.All electrical material shall be new and of the quality and type specified. B.Manufacturer and catalog number shown in these specifications or on drawings are intended as a guide to quality. Equivalent materials and equipment of other manufacturers will be considered provided such substitutions are requested in accordance with the provisions of paragraph 2.03 and shall include all information necessary to support the claim of equivalency. C.No extension of completion date shall be allowed for time lost in consideration, shipping, or installation of approved substitutions. Review of substitutions signifies general equality of materials and equipment only. This review does not relieve the Contractor of responsibility for proper operation of the system, compliance with specifications and necessary changes due to dimensional differences or space requirements. 2.02 SHOP DRAWINGS A.Shop drawings required for this project are as follows: 1.Lighting fixtures 2.Lamps 3.Wiring devices 4.Fire alarm and detection system B.Present shop drawing submittal data at one time, in electronic (PDF) formate, indexed in a newat and orderly manner. Partial submittals will not be accepted. Provide submittal data in accordance with Division 1. C.Place orders for all equipment in time to prevent any delay in construction schedule or completion of project. If any materials or equipment are not ordered in time, additional charges made by equipment manufacturers to complete their equipment in time to meet construction schedule, together with any special handling charges, shall be borne by the Contractor. D.Shop drawings: Contractor agrees that shop drawing submittals processed by the engineer are not change orders; that the purpose of shop drawing submittals by the Contractor is to demonstrate to the engineer that the Contractor understands the design concept, that he demonstrates his understanding by indicating which equipment and material he intends to provide and by detailing the fabrication and installation methods he intends to use. Contractor further agrees that if deviations, discrepancies, or conflicts between shop drawing submittals and contract documents in the form of design drawings and specifications are discovered either prior to or after shop drawing submittals are processed by the engineer, the design drawings and specifications shall control and shall be followed. 2.03 BID ALTERNATE(S) A.Refer to Division 1 for additional information. B.Alternate(s) for Material and Equipment 1.Equipment and material bid alternate(s) shall be proposed as additive or deductive alternate(s) to specified items by submitting it as a separate line item from the base bid on the Bidder's letterhead. 2.Such bid alternate proposals shall not be substituted or included in the base bid. Bid alternate proposal(s) must be accompanied by full descriptive data on the proposed equipment, together with a statement of the cost to be added or deducted for each item. The bid alternate shall include all materials, equipment, labor, connections, coordination with all other trades, etc. for a complete and operational system. 3.The Contractor shall submit the bid alternates at the time the base bids are due. C.Substitutions of Material (Contractor and owner initiated) 1.Other items of material and equipment not listed as equivalents may be offered (at the Contractor's option) as substitutions to specified items by submitting it as a separate price with his base bid on the Bidder's letterhead. 2.Such substitute proposals shall not be included under the base bid and must be accompanied by full descriptive data on the proposed equipment, together with a statement of the cost to be deducted for each item and all deviations from specified items. Highlight all difference from specified equipment. If any such substitutions are to be considered, the Contractor shall submit a list of the proposed substitution items within 14 days of award of contract. Late requests for proposed substitutions shall not be accepted by the Engineer due to scheduling or delivery concerns. 3.If substitutions are rejected, Electrical Contractor shall supply base bid item as specified. 2.04 PRODUCT HANDLING A.Use all means necessary to protect electrical system materials before, during and after installation and to protect the installed work and materials of all other trades. B.In the event of damage, immediately make all repairs and replacements necessary to the approval of the Architect at no additional cost to the Owner. C.Upon completion of all installations, lamping and testing, thoroughly inspect all exposed portions of the electrical installation and completely remove all exposed labels, soil, markings, and foreign materials. PART 3 - EXECUTION 3.01 WORKMANSHIP AND COMPLETION OF INSTALLATION A.Contractor's personnel and subcontractors selected to perform the work shall be well versed and skilled in the trades involved. B.Coordinate electrical equipment and materials installation with other building components. C.Sequence, coordinate, and integrate installations of electrical materials and equipment for efficient flow of the Work. Give particular attention to large equipment requiring positioning prior to closing-in the building. D.Any changes or deviations from the drawings and specifications must be accepted in writing by the Architect/Engineer. All errors in installation shall be corrected at the expense of the Contractor. All specialties shall be installed as detailed on the drawings. Where detail or specific installation requirements are not provided, manufacturer's recommendations shall be followed. E.Upon completion of work, all equipment and materials shall be installed complete, thoroughly checked, correctly adjusted, and left ready for intended use or operation. All work shall be thoroughly cleaned and all residue shall be removed from surfaces. Exterior surfaces of all material and equipment shall be delivered in a perfect, unblemished condition. F.Contractor shall provide a complete installation, including all required labor, material, cartage, insurance, permits, and taxes. 3.02 PROGRESS OF WORK A.Order the progress of electrical work to conform to the progress of the work of the other trades. Complete the entire installation as soon as the condition of the building will permit. Any cost resulting from defective or ill-timed work performed under this Section shall be borne by this Contractor. 3.03 CUTTING AND PATCHING A.Provide all cutting, patching and refinishing or resurfacing required for electrical work in a manner meeting the approval of the Engineer and at no additional cost to the Owner. B.All openings made in fire-rated walls, floors, or ceilings shall be patched and made tight in a manner to conform to the fire rating for the surface penetrated. 3.04 DELIVERY AND STORAGE OF MATERIALS A.Arrange and be held responsible for delivery and safe storage of materials and equipment for electrical installation. B.Carefully check materials furnished to this Contractor for installation, and provide receipt acknowledging acceptance of delivery and condition of the materials received. Thereafter, assume full responsibility for its safekeeping until the final installation has been reviewed and accepted. 3.05 PROTECTION OF WORK AND PROPERTY A.Where there are existing facilities, be responsible for the protection thereof, whether or not such facility is to be removed or relocated. Moving or removing any facility must be done so as not to cause interruption of the work of Owner's operation. B.Close all conduit openings with caps or plugs during installation. Cover all fixtures and equipment and protect against injury. At the final completion, clean all work and deliver in an unblemished condition, or refinish and repaint at the discretion of the Architect. C.Any equipment or conduit systems found to have been damaged or contaminated above “MILL” or “SHOP” conditions shall be replaced or cleaned to the Engineer's satisfaction. 3.06 FINAL ACCEPTANCE A.Final acceptance by the Owner will not occur until all operating instructions are received and Owner's personnel have been thoroughly indoctrinated in the maintenance and operation of all equipment. B.Operating manual, parts lists, and indoctrination of operating and maintenance personnel: Furnish the services of a qualified representative of the supplier for each item or system itemized below who shall instruct specific personnel, as designated by the Owner, in the operation and maintenance of that item or system. C.Instruction shall be made when the particular system is complete and shall be of the number of hours indicated and at the time requested by the Owner. A representative of the Electrical Contractor shall be present for all demonstrations. 1.Lighting control system -4hrs. D.Deliver three (3) complete operating manuals and parts lists to the Owner (or his designated representative) at the time of the above required indoctrination. Fully explain the contents of the manuals as part of required indoctrination and instruct the Owner's personnel in the correct procedure in obtaining service, both during and after the guarantee period. The operating manual and parts lists shall give complete information as to whom the Owner shall contact for service and parts, including the address and phone number. Furnish evidence that an authorized service organization regularly carries a complete stock of repair parts for these items (or systems), and that the organization is available for service. Service shall be furnished within twenty four (24) hours after requested. E.Clean up: Remove all materials, scrap, etc., relative to the electrical installation and leave the premises and all equipment, lamps, fixtures, etc. in a clean, orderly condition. Any costs to the Owner for clean up of the site will be charged against the Contractor. F.Acceptance Demonstration: Upon completion of the work, at a time to be designated by the Architect, the Contractor shall demonstrate for the Owner the operation of the entire installation, including all systems provided under this contract. G.Operating and Acceptance Tests: Provide all labor, instruments, and equipment for the performance of tests as specified. Submit three (3) copies of a typewritten test report for the Architect for his approval. 1.Record the full load current in each phase or line at the main service entrance and for each feeder leaving the main distribution panelboard. Readings shall be taken with the maximum installed load connected and in operation. 2.Perform a careful inspection of the main switchboard bus structure and cable connections to verify that all connections are mechanically and electrically tight. 3.Measure the resistance to ground for the service ground, which shall not exceed ten (10) ohms under normal soil moisture conditions. If required, install additional ground provisions in a manner accepted by the Engineer at no additional cost to the Owner. 3.07 IDENTIFICATION A.General: Provide the following services and materials to assist the Owner in operation and maintenance. B.Directory Cards, Nameplates and Labels: No temporary markings, which are visible on equipment, shall remain after the project is complete. Repaint trims, housing, etc., where such markings cannot be readily removed. Defaced finishes must be refinished. All engraved metal or plastic nameplates shall be white letters on a black or gray background. Raised letter type tape shall not be used. No abbreviations in labeling will be permitted without special approval. All panelboards shall be labeled as designated on the electrical drawings. Thoroughly clean surface to which pressure sensitive type labels are applied to assure adherence of label. Directory cards, nameplates, and labels shall indicate the general area and type of electrical load served by each circuit. Provide the following types of labels at these locations. 1.For all branch circuit panelboard directories, provide neatly typed, removable cards and protective plastic faces. Spare circuit breakers shall be identified as such. 3.08 CONSTRUCTION LIGHTING AND POWER A.Provide all temporary facilities required to supply construction power and light. Install and maintain facilities in a manner that will protect the public and workmen. Comply with all applicable laws and regulations. B.The General Contractor shall pay for all power and light used by him and his subcontractors where construction power is separately metered, or is taken from the permanent project metered service solely for construction use. 3.09 REMODELING PROVISIONS A.Existing systems and conditions shown on the drawings are provided for guidance only. The Electrical Contractor shall field check all existing conditions prior to bidding and shall include in his bid an allowance for the removal and relocation of existing conduits, wires, devices, fixtures, or other equipment as indicated on the plans or as required to coordinate and adapt new and existing electrical systems to all other work required for this project. B.Where the reuse of existing conduits, outlets, junction boxes, etc., is permissible, make certain that the wiring form them is continuous from outlet to outlet. Provide modifications to assure that circuits, or system, shall not pass through outlets or junction boxes which may be rendered inaccessible by changes to be made to the building. Existing conduits, wire, devices, fixtures, etc., which shall be removed shall become the property of this Contractor unless otherwise noted. C.Connect new work to existing in a manner that will assure proper raceway grounding throughout in conformance with the National Electrical Code. D.Remodel Work Cutting and Patching: The Contractor shall perform cutting, channeling, chasing, drilling, etc., as required to install or remove electrical equipment in areas of remodeling. This work shall be performed so as to minimize damage to portions of wall finishes, surfaces, plastering, or the structure which are to be reused, resurfaced, plastered or painted under another division of these specifications. E.Carefully coordinate with the required remodeling work, cutting and patching etc., performed by the other trades. Remove or relocate existing electrical conduits, wires, devices, fixtures and other equipment as necessary. F.All outages on portions of existing electrical systems shall be minimized and shall be at a time and of duration as accepted by the Owner. 3.10 ELECTRICAL DEMOLITION A.Examination 1.Verity field measurements and circuiting arrangements are as shown on drawings. 2.Verify that abandoned wiring and equipment serve only abandoned facilities. 3.Demolition drawings are based on casual field observation and existing record documents. Report discrepancies to Architect before disturbing existing installation. 4.Beginning of demolition means installer accepts existing conditions. B.Preparation 1.Disconnect electrical systems in walls, floors, and ceilings scheduled for removal. 2.Coordination outages with Architect/Owner. 3.Provide temporary wiring and connections to maintain existing systems in service during construction. When work must be performed on energized equipment or circuits, use personnel experienced in such operations. 4.Fire protection, fire alarm, and detection systems shall be maintained and capable of proper operation during construction. The local Fire Marshall shall be notified before construction starts, when scheduled interruptions are expected and after construction is complete. Protect and support life safety systems routed through areas of demolition. 5.Existing telephone system: Maintain existing system in service. Disable system only to make switchovers and connections. Notify Owner/Architect in writing at least 24 hours before partially or completely disabling system. Minimize outage duration. C.Demolition and Extension of Existing Electrical Work 1.Demolish and extend existing electrical work under provisions of Division 1, Division 2, and this section. 2.Remove, relocate, and extend existing installations to accommodate new construction. 3.Remove abandoned wiring to source of supply. 4.Remove exposed abandoned conduit, including abandoned conduit above accessible ceiling finishes. Cut conduit flush with walls and floors, and patch surfaces. 5.Disconnect abandoned outlets and remove devices. Remove abandoned outlets if conduit servicing them is abandoned and removed. Provide blank cover for abandoned outlets, which are not removed. 6.Disconnect and remove electrical devices and equipment serving utilization equipment that has been removed. 7.Disconnect and remove abandoned luminaires. Remove brackets, stems, hangers, and other accessories. 8.Repair adjacent construction and finishes damaged during demolition and extension work. 9.Maintain access to existing electrical installations, which remain active. Modify installation or provide access panel as appropriate. 10.Extend existing installations using materials and methods compatible with existing electrical installation, or as specified in individual section. D.Cleaning and Repair 1.Clean and repair existing materials and equipment, which remain or are to be reused. 2.Panelboards: Clean exposed surfaces and check tightness of electrical connections. Replace damaged circuit breakers and provide closure plates for vacant positions. Provide typed circuit directory showing revised circuiting arrangement. 3.Luminaries: Remove existing luminaires for cleaning. Use mild detergent to clean all exterior and interior surfaces; rinse with clean water and wipe dry. Replace lamps, non-operational ballasts, and broken electrical parts. E.Installation 1.Install relocated materials and equipment under the provisions of Division 1. END OF SECTION 26 00 10 SECTION 26 10 00 - BASIC MATERIALS AND METHODS PART 1 - GENERAL (Not Used) PART 2 - PRODUCTS 2.01 RACEWAYS AND FITTINGS A.Conduit: 1.Conduits subject to mechanical damage or where otherwise required by code shall be galvanized rigid heavy wall conduit; all other conduit may be electric metallic tubing. 2.Flexible metallic conduit shall be used where vibration or other reasons do not allow solid connections to motors, equipment, etc. Flex may also be used to fish in existing walls or where required to connection in millwork. The use of flex shall be held to a minimum. Where flexible metallic conduit is used in areas subject to moisture, PVC-coated flex (Liquidtight) shall be used. B.Fittings: 1.Use solvent welded fittings for all PVC conduit. 2.Use set-screw or compression fittings for all EMT conduit. 3.Use threaded fittings for all rigid conduit. 2.02 WIRE AND CABLE A.Voltage range 0 to 24: High conductivity copper, thermo-plastic insulation, 300 volt rating. B.Voltage range 24 to 600: High conductivity copper, moisture-resistant thermo-plastic insulation, 600 volt 75°C rating for general use. For HID fixtures and wiring within 3 inches of fluorescent ballasts, wire shall be copper, minimum 90°C rated. Sizes indicated are for installation in a maximum 30°C ambient. Conductor ampacity shall be derated for higher ambient installations. C.Conductors used specifically for equipment or service ground may be bare or have insulation to match circuit/feeder conductors. 2.03 WIRE CONNECTIONS A.All electrical connections shall be electrically and mechanically secure, using the following methods: 1.Wire size #8 and smaller--pressure type connectors (scotch-lok) or equivalent. B.Wire termination provisions for panelboards, circuit breakers, safety switches, and all other electrical apparatus shall be listed as suitable for 75°C. 2.04 OUTLET BOXES A.Outlet boxes shall be: one piece steel, galvanized, Steel City Electric, Appleton Electric, Raco or approved equivalent. Where NMC or ENT is used, plastic boxes are acceptable. 2.05 DEVICES A.Wiring devices shall be specification grade and rated at 20 amperes for light switches and 20 amperes for duplex receptacles. Switches, receptacles, and other devices shall be Leviton Decora style, or Pass Seymour, Cooper, or Hubbell equivalent. Color shall be ivory unless noted otherwise by Architect. B.GFCI receptacles shall be straight blade feed through type with indicator light that is lighted when device is tripped. C.Switches shall be 120/277V, 20A, rocker type. D.Wall plates shall be smooth, high-impact thermoplastic material for finished spaces. Smooth, high-impact thermoplastic for unfinished spaces. Cast aluminum with spring-loaded lift cover and listed and labeled for use in “wet locations” in damp spaces. E.Wet locations weatherproof cover plates shall be NEMA250, complying with type 3R weather resistant in-use rating die-cast aluminum with lockable cover. F.Multi outlet assemblies shall be aluminum 4” high, divided channel raceway for use as a complete matching assembly. Duplex 20 amp receptacles shall be located every 18” or as shown in drawings. Route #12AWG minimum. Derate conductors as required by NEC. 2.06 DISCONNECTS A.Safety switches shall be heavy-duty, quick-make, quick-break with cover interlock, fusible or non-fusible, and grounding lugs in enclosure to suit locations and requirements. G.E., Siemens, Square D, Cutler-Hammer. PART 3 - EXECUTION 3.01 CONDUIT INSTALLATION A.All wiring shall be installed in listed metallic raceways. EMT fittings shall be malleable iron or steel. Connectors shall be insulated throat type. B.Make conduit bends with standard conduit elbows or conduit bent to not less than the same radius. All bends shall be free from dents or flattening. C.All fittings in wet places, locations exposed to weather, or buried in masonry, concrete or fill, shall be water-tight. Apply listed compound to threads of raceway and fittings before making up joints. Follow compound manufacturer's instructions. D.At locations subject to moisture or vibration, use insulating bushings to protect conductors, including conductors smaller than No. 4 AWG. E.Cap conduit ends to prevent entrance of foreign materials during construction. F.Run concealed conduits in a direct line. Run exposed conduits parallel to, or at right angles with, lines of the building. Install all conduits at least 6" away from flues, steam and hot water pipes. Install horizontal raceway runs above water and steam piping. G.Seal all conduit penetrations of fire rated walls, floor, or ceilings with U.L. listed "Dow Corning" #2000 or #2001 fire stop sealant or equivalent. H.All empty raceway systems shall have a polypropylene pullwire or equal, and shall be identified at all junction, pull and termination points using permanent metallic tags. Tag shall indicate intended use of conduit, origination, and termination points of each individual conduit. I.Non-metallic and flexible metal conduits shall have a code-sized copper grounding conductor. Increase conduit size as required. J.Conduits penetrating through roof shall have roof flashing with caulk type counter flashing sleeve. Installation shall be watertight. K.Where panels are installed flush with walls, empty conduits shall be extended from the panel to an accessible space above or below. A minimum of one 3/4"c shall be installed for every three single pole spare circuit breakers or spaces, or fraction thereof, but not less than two conduits. 3.02 WIRE INSTALLATION A.Branch circuit conductors shall be as follows: 1.For general applications through size #8: THWN 75oC wire and full size ground, or type THHN 90oC. 2.Branch circuit conductors through size #10 to be solid, #8 and larger stranded. 3.Unless indicated on the drawings, (the minimum) wire used for branch circuits shall be #12 THWN protected by 20 ampere circuit breakers. 4.Branch circuits for receptacles shall be on 20 amp, single pole circuit breakers with #12 conductors. No more than eight (8) duplex receptacles shall be on any one branch circuit. Circuits serving bathroom GFCI receptacles may serve lighting but shall not serve any other receptacles. 5.Lighting branch circuit shall not be loaded to more than 70% of breaker rating, in effect, 14 amps per circuit. B.The drawings indicate the general direction of routes of branch circuit home runs. Continue all such home runs to panels as though the routes were completely indicated. 1.Conductors shall be continuous from outlet box to outlet box, or junction box, with no splices except in such boxes. 2.Do not install wire in conduits until after plastering or drywall is completed and all moisture has been removed from conduits. 3.03 WIRING DEVICE INSTALLATION A.Review architectural and mechanical drawings before installing outlets. Changing of outlets to conform to these drawings and any other slight change in mounting height or location of outlets required shall be considered as a part of this contract. Use outlet boxes of sufficient size and shape to best suit the particular location and to contain the enclosed wire and connections without crowding. Size all boxes per N.E.C. Article 370. B.Switch and receptacle outlet boxes shall be standard boxes with cover plates. Where more than one switch or device is located at one point, use gang boxes and gang cover plates. C.Receptacles in wet locations shall be installed with a hinged outlet cover/enclosure marked “suitable for wet locations while in use” and “UL listed”. There must be a gasket between the enclosure and the mounting surface, and between and hinged cover and mounting plate/base to assure proper seal. Taymac; specification grade or equivalent. D.Flush mount lighting switches 4'0" centerline above finished floor unless otherwise indicated. Flush mount wall type receptacles and other wall mounted wiring devices and outlets one foot centerline above finished floor unless otherwise indicated. E.Route dedicated neutral conductors on line and load side of dimmers per manufacturer's instructions. F.Identify panelboard and circuit number on receptacles with durable wire markers and tags inside outlet boxes. 3.04 DEVICES A.Support all panels, junction boxes and other electrical devices in a manner as required by the N.E.C. Use extra bracing, supports, etc. as necessary to provide a proper and substantial base to which all electrical equipment is attached. B.Bolt-free standing equipment to 4" high concrete housekeeping pads. 3.05 EQUIPMENT FURNISHED BY OTHERS and/or owner A.Verify exact location and requirements of equipment to be furnished by others prior to rough-in. B.See Division 15 drawings for location of mechanical equipment. Provide service to, and connect equipment as required. C.Inspect owner furnished equipment for damage, defects, missing components, etc. Report deficiencies to the Owner immediately. Do not install or connect deficient equipment. D.Rough-in equipment furnished by Owner to locations as required. Final connections will be made by Electrical Contractor. 3.06 EQUIPMENT CONNECTIONS A.Final connections to equipment shall be in accordance with manufacturer's approved wiring diagrams, details, and instructions. It shall be the Contractor's responsibility to provide materials and equipment compatible with equipment actually supplied. END OF SECTION 26 10 00 SECTION 26 50 00 - LIGHTING & LIGHTING CONTROLS PART 1 - GENERAL 1.01 PROVISIONS A.Provide all interior and exterior lighting fixtures as shown on the plans and hereinafter specified. All items shall be provided to make a complete and operable lighting system, including lamps, ballasts, poles, hangers, painting, plaster frames, etc. B.Fixtures shall be as shown in the fixture schedule. Catalog numbers shown are the latest available at the time of design. If discrepancies occur between description and catalog number, description will take precedence. C.Verify trim, finish and general description of all lighting fixtures through shop drawing approval prior to placing order for fixtures. Modify catalog numbers accordingly. D.If it is necessary for the Architect/Engineer to reselect light fixtures which are still available from the manufacturer (i.e. not “discontinued”) but cannot be obtained in time for installation as the result of the contractor's failure to promptly order such fixtures, the contractor shall be back charged at the rate of $75 per hour for the Architect's/Engineer's services. 1.Alternately, the Contractor may be required to pay to air freight fixtures to the construction site at no additional charge to the Owner if this will result in the specified fixtures being available for installation in time to meet the project schedule. PART 2 - PRODUCTS 2.01 LAMPS A.Lamps shall be as shown in the fixture schedule as manufactured by Osram-Sylvania, G.E., Phillips, or approved equivalent. PART 3 - EXECUTION 3.01 INSTALLATION A.Install lighting fixtures straight and true with reference to adjacent walls, and securely fasten to and support by structural members of the building. Refer to architectural or interior reflected ceiling plans and elevations for exact location of fixtures. B.Provide photocontrols, time clocks, contactors, relays, etc. to control interior and exterior fixtures. All items for lighting controls that are to be mounted outdoors or in wet locations shall be installed in weatherproof housings. C.Recessed light fixtures installed in gyp. board or plaster ceilings shall have plaster frames installed prior to ceiling material. D.Fixtures recessed in "t-bar" ceiling shall be supported independently of ceiling system, with four #12 hanger wires up to structure. Secure hanger wires to corners of fixture. Clip fixture to grid on two sides with factory-furnished clips. Final connection to fixture shall be made with a flexible U.L. approved assembly. END OF SECTION 26 50 00 DIVISION 27 - COMMUNICATIONS SYSTEMS SPECIFICATIONS SECTION 27 00 10 - COMMUNICATIONS GENERAL PROVISIONS PART 1 - GENERAL 1.01 DATA SYSTEM A.Provide data service raceways, backboards, wiring, outlets and other devices in accordance with the requirements of the owner's data system vendor. B.Provide convenience outlets at all data terminal boards. C.Provide 100 mega-hertz Category 6, four pair cable to all outlets. Belden Datatwist 6 plenum rated or Lucent, Berk-tek equivalent. Wiring to be routed without any twists or kinks. Individual pairs to be untwisted no more than ½” at each termination point. Contractor to replace any wiring improperly installed at no cost to the owner. Each outlet to be a single run. D.Provide Lucent series M100BH or Amp, Krone equivalent orange modular device at each outlet. E.Contractor to connect branch cable to device. F.Contractor to leave 10 feet minimum cable at terminal boards for connection by data vendor. END OF SECTION 27 00 10 DIVISION 28 - ELECTRONIC SAFETY AND SECURITY SYSTEMS SECTION 28 30 00 -FIRE ALARM SYSTEMS PART 1 - GENERAL 1.02 FIRE ALARM SYSTEM (DESIGN/BUILD) A.GENERAL 1.Combination automatic and manual fire alarm system. Devices shown on Drawings are the minimum acceptable, additional devices and zoning may be required by the Authority Having Jurisdiction (AHJ) and shall be provided at no additional cost to the Owner. Alarm shall achieve minimum of 80db throughout occupiable spaces and meet ADA requirements. 2.The fire alarm system shall be installed under a design/build concept and shall consist of a complete manual and automatic fire alarm system, and all associated appurtenances fully coordinated within all other systems and structure in this project. Include full design calculations with shop drawings prepared, reviewed, and sealed by a registered engineer or NICET Class III Certified Technician. 3.Secure all necessary approvals for a complete fire alarm system acceptable to the Fire Rating Bureau and Fire Marshall/District Having Jurisdiction, and in accordance with the standards set forth in these specifications. 4.The system shall include a central control panel, power supply, signal initiating devices, audible and/or visual alarm devices, a conduit and wiring system, and all accessory devices required to provide a complete operating system. 5.The system shall comply with the applicable provisions of the National Fire Protection Association, (NFPA), Standard 72, Uniform Building Code, Uniform Fire Code, National Electrical Code, Americans with Disabilities Act (ADA), NFPA 70 and 90A. The system shall also meet all requirements of the Fire Marshall or Building Authority Having Jurisdiction. All equipment and devices shall be listed by the Underwriters Laboratories, Inc. Fire alarm panel shall be UL Listed as an assembled unit. 6.Provide shop drawings showing equipment and device locations and connecting wiring of entire fire alarm system. Include wiring diagrams, panel layout drawings, and descriptive literature of all components. Upon completion of project, provide to the Owner as built system plans and 3 sets of system operation and maintenance manuals. 7.To establish the type and quality of system desired, the following equipment is considered equivalent: Pyrotronics, Simplex and Notifier. Other manufacturer's equipment may be considered upon proper submittal per Section 16010. B.Qualifications of Installers: The entire fire alarm system shall be fabricated, installed, and tested by a contractor with five years minimum experience specializing in such systems. If required within jurisdiction of project, contractor shall be a licensed specialist. C.Type of System: The system shall be a hardwired addressable fire alarm system. D.Submittals: 1.Shop drawings: Before any fire alarm system materials are delivered to the job site, submit complete shop drawings to the architect in accordance with the provisions of these specifications. a.Prior to submittal for architect's review, secure approval and stamp of acceptance of the Fire Marshall/District Having Jurisdiction. b.Upon request, the Architect with furnish without charge to the contractor one set of reproducible transparencies of those drawings included in the contractor documents which may be suitable for use in preparation of shop drawings. c.Shop drawings shall include: 1)Layout drawing of the complete fire alarm system indicating relationship of all other overhead items including ceiling air diffusers, lighting fixtures, and all other items. 2)Complete details and sections as required to clearly define and clarify the design, including a materials list describing all proposed materials by manufacturer's name and catalog number. 3)As-Built Drawings: During progress of the work, maintain an accurate record of all changes made in the fire sprinkler system installation from the layout and materials shown on the reviewed shop drawings. 4)Manual: Upon completion of this portion of the work, and as a condition of its acceptance, deliver to the architect a copy of a manual complied in accordance with the provisions of Sections 16010 and 16100 of these specifications; include a copy of the as-built drawings. 1.03 DOORBELL SYSTEM A.Provide doorbell service raceways, backboards, wiring, outlets and all other necessary devices in accordance with the equipment manufacturer's requirements for a complete and operable system. Coordinate requirements with the Owner and Architect. B.Provide rough-in wiring (6 pair) from entry button location to the mechanical room and to the chime location(s). These 6 pair of wires will include standard bell wire and phone system compatible wiring. C.Install home Owner provided items: 1.Door chime, intercom or phone system integration. a.Locate pre-wire for chime as indicated on Architectural drawings. 2.Door chime button. a.Coordinate location with Architect. END OF SECTION 28 30 00 PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® As indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 816578203.11 2018/03/28 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\HOTEL ROOM CORRIDOR\8203.11E001.DWG03.27.1810:10:22 AMALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 2 REVISION 2 3 REVISION 3 ELECTRICAL SPECIFICATIONS E-001 BAS MAS MAS 06/21/18 LUMINAIRE SCHEDULE TYPE DESCRIPTION MOUNTING RECESS DEPTH LAMPS INPUT WATTS VOLT MANUFACTURER CATALOG NUMBER SPECIFIC NOTES QTY TYPE LA-001 RECESSED MOUNTED, ADJUSTABLE WARM-DIM LED ACENT LIGHT WITH 1" CONICAL REGRESSED FLANGELESS TRIM RECESSED 7 1/4" -- LED W/ UNIT 14.5 120-277 SPECIALTY LIGHTING INDUSTRIES GR-IC-AD14-A-AD-NF-L5-GRT-RD- ZT-WHT-91A LA-002 RECESSED INTO MILLWORK, SMALL PROFILE LED LIGHT RECESSED 1/2" -- LED W/ UNIT 2.5 12V MP LIGHTING L52-2-W275-N-A LA-003 SURFACE MOUNTED IN ARCHITECTURAL AND MILLWORK DETAIL, LED LIGHT STRIP IN EXTRUDED ALUMINUM CHANNEL SURFACE -- -- LED W/ UNIT 3.2 W/FT 24VDC LUMINII KS-12-27K-SO-C-A-F1 (1) LA-004 SURFACE MOUNTED, NARROW PROFILE LED LINEAR SURFACE -- -- LED W/ UNIT 12.6 UNV PRULITE LIGHTING HSS-LED3-LO-3'-SAL-SC-UNV-SUR- LDE5-205-DM LA-005 VESTIBULE LED DOWNLIGHT, 5" APERTURE, 3000K COLOR TEMP, 93 CRI RECESSED 7 1/2" -- LED W/ UNIT 11.2 120 LITHONIA 5BPBN LED 30K 90CRI 10-LT-01 ROUND FLUSH MOUNTED FIXTURE WITH METAL FRAME AND ALABASTER DIFFUSER SURFACE -- 2 GREEN CREATIVE #9.5A19DIM/8CCTD 29 120 VISUAL COMFORT KW4013AB 10-LT-02 ROUND FLUSH CEILING MOUNTED FIXTURE WITH ALL FABRIC CONSTRUCTION SURFACE -- 2 GREEN CREATIVE #9.5A19DIM/8CCTD 19 120 CUSTOM REFER TO LIGHTING DESIGNERS SPECIFICATIONS FOR MORE INFORMATION. 10-LT-03 CEILING MOUNTED FIXTURE AT BATHROOM SURFACE -- 2 GREEN CREATIVE #9.5A19DIM/8CCTD 40 120 SHADES OF LIGHT FM17010 (4) 10-LT-08 WALL SCONCE AT BATHROOM SURFACE -- 2 GREEN CREATIVE #3.5FB10DIM/827/E26 40 120 SHADES OF LIGHT SC15116 (4) 11-LT-01 ROUND FLUSH MOUNT CEILING FIXTURE WITH FABRIC DRUM SHADE SURFACE -- 3 GREEN CREATIVE #9.5A19DIM/8CCTD 60 120 BOYD LIGHTING 10049 (4) 11-LT-02 WALL SCONCE , OUTER WATER GLASS WITH AN INNER FROSTED OPAL GLASS WITH WAVE PATTERN SURFACE -- 1 GREEN CREATIVE #9.5A19DIM/8CCTD 20 120 SHADES OF LIGHT SC15095 BZ (4) GENERAL NOTES: A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS SHALL NOT QUOTE PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS AND ELECTRICAL DIVISION SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY DRAWINGS AND SPECIFICATIONS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING. B. REFER TO DRAWINGS FOR FIXTURES REQUIRING EMERGENCY BATTERY BACKUP OPTION (SHOWN BY HATCH IN/OVER SYMBOL). MINIMUM LIGHT OUTPUT FOR EM BALLAST SHALL BE 600 LUMENS. C. ALL FLUORESCENT LAMPS ARE TO BE 3500° KELVIN COLOR TEMPERATURE SPECIFIC NOTES: (1) PROVIDE LUMINII #PSV-40-24-U2DIM-D POWER SUPPLY UNLESS NOTED OTHERWISE. (2) PROVIDE LUMINII #PSV-60-24-U2DIM-D POWER SUPPLY UNLESS NOTED OTHERWISE. (3) PROVIDE LUMINII #PSV-96-24-U2DIM-D POWER SUPPLY UNLESS NOTED OTHERWISE. (4) PROVIDE FACTORY INSTALLED LABEL INDICATING MAX WATTAGE PER SOCKET IS 20 WATTS. T (E)MSB-A 3000A 277/480V, 3ɸ, 4W T (E)MSB-B 3000A 277/480V, 3ɸ, 4W T T (E)TR-2 (E)TR-3 (E)UTILITY TRANSFORMER (E)DSBH 1600A 120/208V, 3ɸ, 4W (E) DP-D5B (E) PP-P5B LEVEL 1 LEVEL 3 LEVEL 5 LEVEL 6 SCALE:1 EXISTING ELECTRICAL ONE-LINE DIAGRAM NOT TO SCALE PANEL: (E) PP-P5B VOLTAGE: 120/208V, 3PH, 4W MINIMUM BUS: 225 LOCATION: ELECTRICAL G-513 MAIN: MLO MOUNTING: SURFACE MINIMUM AIC: NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B C POLE TRIP A B C TRIP POLE A B C 85 EXISTING LOAD 1 20 + 20 1 EXISTING LOAD 86 87 EXISTING LOAD 1 20 + 20 1 EXISTING LOAD 88 89 EXISTING LOAD 1 20 + 20 1 EXISTING LOAD 90 91 EXISTING LOAD 1 20 + 20 1 EXISTING LOAD 92 93 EXISTING LOAD 1 20 + 20 1 EXISTING LOAD 94 95 EXISTING LOAD 1 20 + 20 1 EXISTING LOAD 96 97 SPARE 3 20 + 20 1 EXISTING LOAD 98 99 -- -- -- + 20 1 EXISTING LOAD 100 101 -- -- -- + 20 1 EXISTING LOAD 102 103 R (N) RM 5036 REC/DRAPS 1 20 + 20 1 EXISTING LOAD 104 105 EXISTING LOAD 1 20 + 20 1 EXISTING LOAD 106 107 E (N) SIGNAGE 1 20 + 20 1 EXISTING LOAD 108 109 EXISTING LOAD 1 20 + 20 1 EXISTING LOAD 110 111 EXISTING LOAD 1 20 + SPACE 112 113 EXISTING LOAD 1 20 + SPACE 114 115 EXISTING LOAD 1 20 + 100 3 SPARE 116 117 EXISTING LOAD 1 20 + -- -- -- 118 119 SPARE 1 20 + -- -- -- 120 121 SPARE 3 20 + SPACE 122 123 -- -- -- + SPACE 124 125 -- -- -- + SPACE 126 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. NEW LOADS NOTED WITH (N). (L) LIGHTING 0 0 125% 0 B. (R) RECEPTACLES 0 0 NEC 220 0 C. (LM) LARGEST MOTOR 0 0 25% 0 D. (M) MOTORS (ALL) 0 0 100% 0 E. (E) EQUIPMENT 0 0 100% 0 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 (1) PANEL TOTAL (KVA): 0.0 (2) (3) PANEL TOTAL (A): 0 (4) (5) METER PANEL 'PP-P5B' FOR 30-DAYS PER NEC 220.87 TO DETERMINE AVAILABLE LOAD CAPACITY. IT IS ASSUMED AT TIME OF PERMIT, PANEL 'PP-P5B' HAS SUFFICIENT CAPACITY FOR ADDED LOADS. ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL ENGINEER WITH METERED DATA PRIOR TO INSTALLATION OF ELECTRICAL SYSTEMS TO VERIFY SUFFICIENT CAPACITY IN PANEL. THE LOAD BEING ADDED TO PANEL 'PP-P5B' IS AS FOLLOWS: 1. RECEPTACLES = 720 VA 2. DIGITAL SIGNAGE = 350 VA 3. LUTRON CONTROL PANEL = 10 VA 4. MOTORIZED SHADES = 100 VA TOTAL = 1,180 VA THIS IS A TOTAL ADDED LOAD TO PANEL 'PP-P5B' OF 3.3 AMPS AT 208 VOLT, 3-PHASE PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® As indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 816578203.11 2018/03/28 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\HOTEL ROOM CORRIDOR\8203.11E002.DWG03.27.1810:10:30 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 2 REVISION 2 3 REVISION 3 ELECTRICAL SCHEDULES E-002 BAS MAS MAS 06/21/18 ENTRY CLOSET BEDROOM BATHROOM ENTRY CLOSET BEDROOM BATHROOM SCALE: 1 ROOM 5036 ELECTRICAL DEMO PLAN 1/4" = 1'-0" SCALE: 2 ROOM 5036 ELECTRICAL PLAN 1/4" = 1'-0" J+60" C C J T +12" +12" +12" +12" +12" +50" +12" J CH TV C C C C J FP C J (E)FP (E) (E) (E) 1. METER PANEL 'PP-P5B' FOR 30-DAYS PER NEC 220.87 TO DETERMINE AVAILABLE LOAD CAPACITY. IT IS ASSUMED AT TIME OF PERMIT, PANEL 'PP-P5B' HAS SUFFICIENT CAPACITY FOR ADDED LOADS. ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL ENGINEER WITH METERED DATA PRIOR TO INSTALLATION OF ELECTRICAL SYSTEMS TO VERIFY SUFFICIENT CAPACITY IN PANEL. 2. FIRE ALARM SCOPE LIMITED TO REMODEL PORTION OF BUILDING ONLY. FIRE ALARM SYSTEM SHALL BE DESIGN/BUILD BY CONTRACTOR. FIRE ALARM DEVICES SHOWN ON PLAN ARE FOR DESIGN INTENT. FINAL DESIGN RESPONSIBILITY BY DESIGN/BUILD CONTRACTOR. NOTES: FLAG NOTES: 1 REUSE EXISTING ELECTRICAL CIRCUIT IN THIS AREA. PROVIDE 20A, 120V ELECTRICAL FEED TO JUNCTION BOX FOR NEW DIGITAL SIGNAGE. PROVIDE 20A, 120V ELECTRICAL FEED TO JUNCTION BOX FOR MIRROR. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER SUBMITTAL PRIOR TO ROUGH-IN. EXTEND EXISTING LIGHTING CIRCUIT IN BATHROOM TO JUNCTION BOX. LUTRON CONTROL PANEL AND DIMMING PANEL. PROVIDE DUPLEX RECEPTACLE WITH (2) USB CHARGING PORTS. RECEPTACLE SHALL BE MOUNTED HORIZONTALLY ADJACENT TO LIGHTING CONTROL KEYPAD SHOWN ON EL-100. 1 DEMOLITION NOTES: 1. ELECTRICAL CONTRACTOR SHALL REMOVE ALL DEMOLISHED ITEMS FROM SITE UNLESS OWNER WISHES TO RETAIN. ITEMS REMOVED FROM SITE SHALL BE DISPOSED OF IN A LEGAL MANNER. 2. FOR ALL ITEMS TO BE DEMOLISHED, REMOVE CIRCUIT BACK TO POINT OF CONNECTION. MAKE BRANCH CIRCUIT WITH REMAINING DEVICES CONTINUOUS. 3. NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES OF INFORMATION REPRESENTED IN THE DOCUMENTS VERSUS WHAT IS FOUND IN THE FIELD. 4. ALL DEVICES/EQUIPMENT DENOTED WITH (E) ARE EXISTING TO REMAIN. 1 1 1 1 PP-P5B-103 PP-P5B-103 PP-P5B-103 PP-P5B-103 PP-P5B-107 PP-P5B-103 J +60" J +60" (E) +60" 2 2 3 3 H CO 44 H(E) 5 5 5 1 +50" PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® As indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 816578203.11 2018/03/28 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\HOTEL ROOM CORRIDOR\8203.11E100.DWG03.27.1810:10:36 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 2 REVISION 2 3 REVISION 3 ROOM 5036 ELECTRICAL PLANS E-100 BAS MAS MAS 06/21/18 SCALE:1 CORRIDOR ELECTRICAL PLAN 1/8" = 1'-0" J J J J J J J PP-P5B-107 PP-P5B-107 PP-P5B-107 PP-P5B-107 PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® As indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 816578203.11 2018/03/28 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\HOTEL ROOM CORRIDOR\8203.11E102.DWG03.27.1810:10:42 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks ˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 2 REVISION 2 3 REVISION 3 MODEL CORRIDOR ELECTRICAL PLANS E-102 BAS MAS MAS 06/21/18 NO SCALE TYPICAL DEVICE ALIGNMENT EQ EQ 6"MIN. ℄ ℄ ℄ DOOR WINDOW EQ EQ ℄LIGHTING CONTROL ℄ ℄ OFFSET COMMUNICATIONS DEVICES FROM POWER DEVICES TO EITHER OPPOSITE SIDE OF STUD BAY, OR ADJACENT STUD BAY. NOTES: 1. IF ALIGNMENT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. EQ BACKSPLASH ABOVE COUNTER DEVICE RECEPTACLE COUNTERTOP EQ FINISHED FLOOR FINISHED CEILING 6" MIN. 20" MAX. ALIGN DEVICES (OUTLETS, CONTROLS, ETC.) VERTICALLY. DO NOT VERTICALLY ALIGN POWER AND COMMUNICATIONS DEVICES SIMULTANEOUSLY. 18" 48"64" 78" 90" 78" 64" 90" 6"MIN FIRE ALARM DEVICES 48" ELECTRICAL DEVICES 96" NOTES: 1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. WALL-MOUNT NO SCALE TYPICAL DEVICE MOUNTING HEIGHTS OC DLV S CBC TS TC ANN FACP SH SH F 120" MAX. 80" MIN. 96" MAX. TOP OF DEVICE 9'-0"+ CEILING 8'-0" CEILING TOP OF CABINET TOP OF CABINET TOP OF DEVICE CL OF DEVICE TOP OF DEVICE TOP OF CABINET TOP OF CABINET BOTTOM OF DEVICE MINIMUM, TOP OF DEVICE FINISHED FLOOR FINISHED CEILING 18" TOP OF DEVICE 48" MINIMUM, TOP OF DEVICE BOTTOM OF DEVICE TOP OF CABINET TOP OF CABINET 90" 6"MIN. 96" NOTES: 1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. TYPICAL DEVICE MOUNTING HEIGHTS I I CR FINISHED FLOOR 48" 84" FINISHED CEILING 90" 78" 64" 24" NO SCALE I WALL-MTDCABINET CPUAPS ACP K C VCT CK MAV TV S ANN FACP SH SH F 80" MIN. 96" MAX. 120" MAX. CL OF DEVICE CL OF DEVICE TOP OF DEVICE TOP OF CABINET 8'-0" CEILING 9'-0"+ CEILING CL OF DEVICE LOW VOLTAGE DEVICES FIRE ALARM DEVICES PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® As indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 816578203.11 2018/03/28 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\HOTEL ROOM CORRIDOR\8203.11E300.DWG03.27.1810:11:01 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 2 REVISION 2 3 REVISION 3 ELECTRICAL DIAGRAMS E-300 BAS MAS MAS 06/21/18 ENTRY CLOSET BEDROOM BATHROOM ENTRY CLOSET BEDROOM BATHROOM SCALE: 1 ROOM 5036 LIGHTING DEMO PLAN 1/4" = 1'-0" SCALE: 2 ROOM 5036 LIGHTING PLAN 1/4" = 1'-0" 10-LT-03 10-LT-01 10-LT-02 10-LT-08 10-LT-08 KSJ K Q KF5 KD4AK D4A A4 KA1B1OS LA-002 FLAG NOTES: 1 LUTRON CONTROL PANEL AND DIMMING PANEL. 1 LA-003 LA-004 DEMOLITION NOTES: 1. ELECTRICAL CONTRACTOR SHALL REMOVE ALL DEMOLISHED ITEMS FROM SITE UNLESS OWNER WISHES TO RETAIN. ITEMS REMOVED FROM SITE SHALL BE DISPOSED OF IN A LEGAL MANNER. 2. FOR ALL ITEMS TO BE DEMOLISHED, REMOVE CIRCUIT BACK TO POINT OF CONNECTION. MAKE BRANCH CIRCUIT WITH REMAINING DEVICES CONTINUOUS. 3. NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES OF INFORMATION REPRESENTED IN THE DOCUMENTS VERSUS WHAT IS FOUND IN THE FIELD. 4. ALL DEVICES/EQUIPMENT DENOTED WITH (E) ARE EXISTING TO REMAIN. 1. ELECTRICAL CONTRACTOR SHALL LOCATE ALL NECESSARY POWER SUPPLIES FOR LED LIGHT STRIP FIXTURES IN AN ACCESSIBLE LOCATION. COORDINATE EXACT LOCATION WITH LIGHTING DESIGNER PRIOR TO ROUGH-IN. REFER TO LUMINAIRE SCHEDULE ON SHEET E-001 FOR POWER SUPPLY SPECIFICATION. 2. NEW LIGHTING IS LOWER WATTAGE THAN EXISTING LIGHTING BEING REMOVED. EXTEND EXISTING ELECTRICAL CIRCUIT TO INCLUDE NEW LIGHTING. 3. REFER TO DRAWING E-007 OF THE FOUR SEASONS DESIGN STANDARDS AND LUTRON DRAWINGS IN CONSTRUCTION SET FOR LIGHTING CONTROL INTENT. NOTES: LA-003 LA-003 LA-001 LA-001 OS OS PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® As indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 816578203.11 2018/03/28 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\HOTEL ROOM CORRIDOR\8203.11EL100.DWG03.27.1810:10:56 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 2 REVISION 2 3 REVISION 3 ROOM 5036 LIGHTING PLANS EL-100 BAS MAS MAS 06/21/18 SCALE:1 CORRIDOR LIGHTING DEMO PLAN 1/8" = 1'-0" SCALE:2 CORRIDOR LIGHTING PLAN 1/8" = 1'-0" DEMOLITION NOTES: 1. ELECTRICAL CONTRACTOR SHALL REMOVE ALL DEMOLISHED ITEMS FROM SITE UNLESS OWNER WISHES TO RETAIN. ITEMS REMOVED FROM SITE SHALL BE DISPOSED OF IN A LEGAL MANNER. 2. FOR ALL ITEMS TO BE DEMOLISHED, REMOVE CIRCUIT BACK TO POINT OF CONNECTION. MAKE BRANCH CIRCUIT WITH REMAINING DEVICES CONTINUOUS. 3. NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES OF INFORMATION REPRESENTED IN THE DOCUMENTS VERSUS WHAT IS FOUND IN THE FIELD. 4. ALL DEVICES/EQUIPMENT DENOTED WITH (E) ARE EXISTING TO REMAIN. 11-LT-01 11-LT-01 11-LT-01 11-LT-01 11-LT-01 11-LT-02 11-LT-02 11-LT-02 11-LT-02 11-LT-02 11-LT-02 11-LT-02 11-LT-02 1. NEW LIGHTING IS LOWER WATTAGE THAN EXISTING LIGHTING BEING REMOVED. NOTES: (E) (E) FLAG NOTES: 1 EXTEND EXISTING EMERGENCY GENERATOR ELECTRICAL CIRCUIT TO NEW LIGHTING FIXTURE. REMOVE EXISTING FIXTURE AND REPLACE WITH NEW FIXTURE IN PLACE. CONNECT EXISTING ELECTRICAL CIRCUIT IN PLACE. 1 1 1 11 (E)(E) (E) (E) (E)(E) (E) LA-005 LA-005 LA-005 LA-005 LA-005 LA-005 LA-005 LA-005 LA-005 LA-005 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® As indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 816578203.11 2018/03/28 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\HOTEL ROOM CORRIDOR\8203.11EL102.DWG03.27.1810:10:49 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 8203.11 Copyright 2017 1 REVISION 1 2 REVISION 2 3 REVISION 3 MODEL CORRIDOR LIGHTING PLANS EL-102 BAS MAS MAS 06/21/18 EX VAIL LLC EXTELL DEVELOPMENT COMPANY 805 THIRD AVENUE NEW YORK, NY 10022 VOICE: 212.712.6000 OWNER JEFFREY BEERS INTERNATIONAL 156 FIFTH AVE PENTHOUSE II NEW YORK, NY 10010 VOICE: 212.352.2020 INTERIOR DESIGNER BG BUILDINGWORKS 1626 COLE BOULEVARD, BUILDING 7-SUITE 300 LAKEWOOD, CO 80401 VOICE: 303.278.3820 MPE OZ ARCHITECTURE 3003 LARIMER STREET DENVER, CO 80205 VOICE: 303.861.5704 ARCHITECT THE KORTE COMPANY 12441 U.S. HIGHWAY 40 HIGHLAND, IL 62249 VOICE: 618.654.8611 CONTRACTOR APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 INTERNATIONAL PLUMBING CODE (IPC) 2012 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2009 ICC/ANSI A117.1 2014 NATIONAL ELECTRICAL CODE (NEC) TOWN OF VAIL LOCAL AMENDMENTS BUILDING OCCUPANCY CLASSIFICATION: R-1 ROOM 5036 OCCUPANCY CLASSIFICATION: R-1 ROOM 5036 SF: 575 (NO CHANGE FROM EXISTING) ROOM 5036 OLF: 200 ROOM 5036 OCCUPANT LOAD: 3 CONSTRUCTION TYPE: TYPE 1-B FIRE RESISTIVE FIRE SUPPRESSION: FULLY SPRINKLERED PER NFPA 13. (EXISTING TO REMAIN) PROJECT LOCATION MODEL CORRIDOR UNIT 5036 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®3/28/2018 1:19:52 PM C:\Revit Local Files\116194.00_Four Seasons Vail__A17_GR and Corridor Permit Set_kadams.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/03/28 ISSUE FOR BUILDING PERMIT ROOM 5036 & MODEL CORRIDOR COVER G-001A FOUR SEASONS RESORT AT VAIL OZ FOUR SEASONS RESORT AT VAIL ISSUE FOR BUILDING PERMIT 2018/03/28 ONE VAIL ROAD VAIL, CO 81657 PTD PAPER TOWEL DISPENSER PTDR PAPER TOWEL DISPENSER AND RECEPTACLE PTN PARTITION PTR PAPER TOWEL RECEPTACLE PVC POLYVINYL CHLORIDE PVMT PAVEMENT QT QUARRY TILE QTY QUANTITY (R) REMOVE R RISER RAD RADIUS RB RUBBER BASE RBC RUBBER BASE COVE RBS RUBBER BASE STRAIGHT RBT RUBBER TILE RD ROOF DRAIN or ROAD RE REFER TO or REFERENCE REC RECESS(ED) RECPT RECEPTACLE REF REFRIGERATOR or REFRIGERATED REINF REINFORCED REQD REQUIRED RESIL RESILIENT REV REVISE, REVISED or REVISION(S) RF RESILIENT FLOORING RFG ROOFING RFL REFLECTED RH RIGHT HAND RL RAIN LEADER RM ROOM RO ROUGH OPENING ROD ROOF OVERFLOW DRAIN ROW RIGHT OF WAY RPM REVOLUTIONS PER MINUTE RVS REVERSE (SIDE) RWC RAIN WATER CONDUCTOR S SOUTH or SEALED SC SOLID CORE SCD SEAT COVER DISPENSER SCHED SCHEDULE SD SOAP DISPENSER SEC SECTION SF SQUARE FEET SHT SHEET SHTG SHEATHING SHWR SHOWER SIM SIMILAR SNC SANITARY NAPKIN CABINET SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SOFF SOFFIT SPECS SPECIFICATION(S) SPKL SPRINKLER SPKR SPEAKER SPRT SUPPORT SQ SQUARE SR SINK RECEPTACLE SS STAINLESS STEEL or SOLID SURFACE SSK SERVICE SINK STA STATION STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURE or STRUCTURAL SUSP SUSPEND(ED) SYM SYMMETRICAL SYS SYSTEM T TREAD T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TB TOWEL BAR TBC TOP OF BACK OF CURB TELE TELEPHONE TEMP TEMPORARY or TEMPERATURE TG TEMPERED GLASS THERM THERMOSTAT THK THICK or THICKNESS THLD THRESHOLD TO TOP OF TOC TOP OF CONCRETE TOS TOP OF STEEL TOW TOP OF WALL TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TS TUBE STEEL TV TELEVISION TYP TYPICAL UL UNDERWRITER'S LABORATORY UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE UOS UNLESS OTHERWISE SPECIFIED UR. URINAL USGS U.S. GEOLOGICAL SURVEY V VOLT VAR VARY or VARIES VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VENT VENTILATION VER VERIFY VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VIN VINYL or SHEET VINYL VOL VOLUME VTR VENT THROUGH ROOF VWC VINYL WALL COVERING W WEST or WIDE W.O. WHERE OCCURS W/ WITH W/C WATER CLOSET W/O WITHOUT W/R WATER RESISTANT WC WALL COVERING WD WOOD WDO WINDOW WF. WIDE FLANGE or WOOD FLOORING WGL WIRE GLASS WP WATERPROOF(ING) WPT WORKING POINT WSCT WAINSCOT WT WEIGHT WWF WELDED WIRE FABRIC YD YARD FTG FOOTING FURN FURNISH(ED) FURR FURRED or FURRING FUT FUTURE FVC FIRE VALVE CABINET GA GAUGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GCMU GLAZED CONCRETE MASONRY UNIT(S) GI GALVANIZED IRON GL GLASS or GLAZING GND GROUND GR GRADE GRT GROUT GT GLASS TILE GWB GYPSUM WALLBOARD GYP GYPSUM GYP. BD. GYPSUM BOARD HAS HEADED ANCHOR STUD HB HOSE BIB HC HOLLOW CORE or HANDICAPPED HDAS HEADED DEFORMED ANCHOR STUD HDR HEADER HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HTR HEATER HVAC HEATING, VENTILATION and AIR CONDITIONING HW HOT WATER HWH HOT WATER HEATER HWY HIGHWAY IBC INTERNATIONAL BUILDING CODE or INSTALLED BY CONTRACTOR ID INSIDE DIAMETER IN INCH(ES) INCAND INCANDESCENT INCL INCLUD(ED) INFO INFORMATION INSUL INSULATION or INSULATED INT INTERIOR INTMED INTERMEDIATE INV INVERT JC JANITOR CLOSET JST JOIST JT JOINT KD KNOCKDOWN KIT KITCHEN KO KNOCKOUT KP KICK PLATE LAB LABORATORY LAM LAMINATE LAV LAVATORY LBL LABEL LDR LEADER LH LEFT HAND LKR LOCKER LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LP LIGHTING PANEL or LIGHT PROOF LT LIGHT LTL LINTEL LVR LOUVER MACH MACHINERY MAG MAGNETIC MAS MASONRY MATL MATERIAL MAX MAXIMUM MB MOISTURE BARRIER MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEP MECHANICAL, ELECTRICAL and PLUMBING MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE MIN MINIMUM MIRR MIRROR MISC MISCELLANEOUS MM MILLIMETERS MO MASONRY OPENING MTD MOUNT(ED) MTL METAL MUL MULLION (N) NEW N NORTH NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OFF OFFICE OH OPPOSITE HAND OPNG OPENING OPP OPPOSITE OTO OUTSIDE-TO-OUTSIDE P PAINT(ED) P/L PROPERTY LINE PAC PREVIOUSLY AWARDED CONTRACT PAR PARALLEL PBO PROVIDED BY OTHERS PC PRECAST PERF PERFORATED PERIM PERIMETER PKG PARKING PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER PLBG PLUMBING PLYWD PLYWOOD PNL PANEL POL POLISHED PR PAIR or PROPOSAL REQUEST PREFAB PREFABRICATED PREFIN PREFINISHED PRESTR PRESTRESSED PRIM PRIMARY PROJ PROJECT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POST TENSIONED or PORCELAIN TILE PT POINT OF TANGENCY # POUND(S) OR NUMBER & AND < ANGLE @ AT A/V AUDIO/VISUAL AB ANCHOR BOLT ABV ABOVE ACOUS ACCOUSTICAL ACT ACCOUSTICAL CEILING TILE AD AREA DRAIN or ACCESS DOOR ADD ADDENDUM ADJ ADJACENT or ADJUSTABLE AFF ABOVE FINISHED FLOOR AGG AGGREGATE AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE ARCH ARCHITECTURAL ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS ASPH ASPHALT AUTO AUTOMATIC AVE AVENUE AVG AVERAGE AWP ACOUSTICAL WALL PANEL B BASE B.O. BY OWNER B.O.F. BY OWNER, FUTURE BD BOARD BIT BITUMINOUS BLDG BUILDING BLKG BLOCKING BM BEAM or BENCH MARK BOT BOTTOM BRG BEARNING BSMT BASEMENT C CAULKING C.L. CENTERLINE CAB CABINET CATV CABLE TELEVISION CCD CONSTRUCTION CHANGE DIRECTIVE CCTV CLOSED CIRCUIT TELEVISION CDOT COLORADO DEPARTMENT OF TRANSPORTATION CEM CEMENTITIOUS CFL COUNTERFLASHING CG CORNER GUARD CIP CAST IN PLACE CIRC CIRCUMFERENCE CJ CONTROL JOINT CK CORK TILE CL COLUMN LINE CLG CEILING CLOS CLOSET CLR CLEAR CM CENTIMETERS CMU CONCRETE MASONRY UNIT CO CHANGE ORDER or CLEANOUT COL COLUMN CONC CONCRETE CONF CONFERENCE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CORR CORRIDOR or CORRUGATED CPT CARPET CT CERAMIC TILE CTR COUNTER CU CUBIC CY CUBIC YARD DAMP DAMPROOFING DBL DOUBLE DEG DEGREE DEMO DEMOLISH or DEMOLITION DEPT DEPARTMENT DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN DR DOOR DS DOWNSPOUT DTL DETAIL DWG DRAWING DWR DRAWER (E) EXISTING E EAST EA EACH EB EXPANSION BOLT ED EXHAUST DUCT EF EXHAUST FAN or EACH FACE EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EMER EMERGENCY ENGR ENGINEER EOS EDGE OF SLAB EQ EQUAL EQUIP EQUIPMENT ES EACH SIDE EST ESTIMATE EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXT EXTERIOR F FARENHEIT FA FIRE ALARM FAC FIRE ALARM CABINET FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHER(S) FD FLOOR DRAIN or FIRE DAMPER FDN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FFL FINISHED FLOOR LINE FH FIRE HYDRANT FHC FIRE HOSE CABINET FHMS FLAT HEAD MACHINE SCREW FHV FIRE HOSE VALVE FHWS FLAT HEAD WOOD SCREW FIN FINISH(ED) FIXT FIXTURE FLG FLASHING FLR FLOOR(ING) FLUOR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUD FR FIRE RESISTIVE or FIRE RATED FRP FIBERGLASS REINFORCED PANEL(ING FRT FIRE RETARDANT TREATED FT FOOT (FEET) TRUE NORTH ABBREVIATIONS GENERAL NOTES GRAPHIC STANDARDS PROJECT TEAM VICINITY MAP DRAWING INDEX PROJECT NOTES 1 THE TERM “GC” SHALL MEAN THE GENERAL CONTRACTOR AND ITS SUB-CONTRACTORS. 2 THE GC SHALL THOROUGHLY FAMILIARIZE ITSELF WITH THE CONTRACT DOCUMENTS AND THE SITE. SHOULD THE GC FIND DISCREPANCIES IN, OR OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS, SHOULD THE GC BE IN DOUBT AS TO THEIR INTENT OR MEANING, OR HAS QUESTIONS CONCERNING CONSTRUCTABILITY OR CODE COMPLIANCE, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. SHOULD A CONFLICT OCCUR BETWEEN THE DRAWINGS AND SPECIFICATIONS THAT IMPLYING GREATER QUANTITY OR QUALITY SHALL PREVAIL. 3 THE INTENT OF THE CONTRACT DOCUMENTS IS TO PROVIDE A COMPLETE PROJECT. EVERY ITEM NECESSARILY REQUIRED MAY NOT BE SPECIFICALLY MENTIONED OR SHOWN. UNLESS EXPRESSLY STATED, SYSTEMS AND EQUIPMENT SHALL BE COMPLETELY OPERATIONAL. PROVIDE INCIDENTAL, ACCESSORY, AND ANY OTHER ITEMS NOT SPECIFIED, BUT REQUIRED, FOR A COMPLETE AND FINISHED ASSEMBLY. 4 THE ENTIRE SET OF CONTRACT DOCUMENTS REPRESENT THE PROJECT AS A WHOLE. THE GC IS RESPONSIBLE FOR PROVIDING SUFFICIENT INFORMATION TO ITS SUB-CONTRACTORS TO DETERMINE AND PERFORM THEIR SCOPE OF WORK. 5 ANY ELECTRONIC CAD AND/OR BUILDING INFORMATION MODELING (BIM) FILES PROVIDED BY THE ARCHITECT OR ITS CONSULTANTS IS SOLELY TO ASSIST THE GC IN PREPARATION OF SHOP DRAWINGS AND/OR LAYOUT OF THE PROJECT. CAD AND BIM FILES ARE NOT A PART OF THE CONTRACT DOCUMENTS AND ANY INFORMATION CONTAINED THEREIN DOES NOT SUPERSEDE ANY INFORMATION ON THE CONTRACT DOCUMENTS. 6 THE GC IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION, COORDINATION OF TRADES, AND SCHEDULING OF THE WORK. 7 THE GC SHALL NOT REVISE, SUBSTITUTE, OR CHANGE THE WORK WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. 8 NOT EVERY CONDITION MAY BE DRAWN OR DETAILED. CONDITIONS SIMILAR TO DETAILED CONDITIONS SHALL BE CONSTRUCTED TO THE SAME SIZE AND CHARACTER AS THOSE FOR SIMILAR CONDITIONS. 9 THE GC SHALL FOLLOW THE RECOMMENDATIONS OF THE OWNER’S GEOTECHNICAL CONSULTANT. SHOULD THE GC FIND DISCREPANCIES WITH THE CONTRACT DOCUMENTS, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 10 DO NOT SCALE DRAWINGS. 11 PROVIDE NECESSARY BLOCKING IN WALLS, PARTITIONS, AND CEILINGS FOR ITEMS INCLUDING, BUT NOT LIMITED TO: CEILING AND PARTITION-MOUNTED FIXTURES, GRAB BARS, HANDRAILS, TOILET ACCESSORIES, CABINETRY, PANELING, COUNTERTOPS, SHELVES, CLOSET RODS, WHITE BOARDS, AND DECORATIVE ELEMENTS. 12 THE CONSTRUCTION DOCUMENTS ARE THE PROPERTY OF OZ ARCHITECTURE, INC. AND ITS CONSULTANTS AND ARE TO BE USED AS INSTRUMENTS OF SERVICE FOR CONSTRUCTION OF THIS PROJECT ONLY. USE OF THESE DOCUMENTS BY THE GC FOR ANY OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN CONSENT OF OZ ARCHITECTURE IS PROHIBITED. MODEL ROOM 5036 & COORIDOR BUILDING CODES TRUE NORTH KEY MAP Sheet Number Sheet Name GENERAL G-001A ROOM 5036 & MODEL CORRIDOR COVER G-100 SPECIFICATIONS 6103 &5036 G-101 SPECIFICATIONS 6103 &5036 G-102 SPECIFICATIONS 6103 &5036 ARCHITECTURE A-100A ROOM 5036 - DEMO PLAN, FLOOR PLAN, & RCP A-102A MODEL CORRIDOR - DEMO PLAN, FLOOR PLAN + REFLECTED CEILING PLAN 5036 INTERIORS I-000-000A INDEX COVER SHEET 5036 I-000-001A INDEX GENERAL NOTES 5036 I-000-002A INDEX SYMBOLS 5036 I-000-003A INDEX DRAWING LOG 5036 I-10-001 MODEL GUESTROOM 5036 DEMO PLAN I-10-101 MODEL GUESTROOM 5036 FURNITURE PLAN I-10-201 MODEL GUESTROOM 5036 ARCHITECTURAL PLAN I-10-301 MODEL GUESTROOM 5036 REFLECTED CEILING PLAN I-10-401 MODEL GUESTROOM 5036 POWER AND DATA PLAN I-10-501 MODEL GUESTROOM 5036 FLOOR FINISH PLAN I-10-601 MODEL GUESTROOM 5036 ELEVATIONS I-10-602 MODEL GUESTROOM 5036 ELEVATIONS I-10-603 MODEL GUESTROOM 5036 ELEVATIONS I-10-701 MODEL GUESTROOM 5036 MINIBAR DETAILS I-10-702 MODEL GUESTROOM 5036 CLOSET DOOR DETAILS I-10-703 MODEL GUESTROOM 5036 DRAPERY DETAILS I-10-704 MODEL GUESTROOM 5036 FIREPLACE DETAILS I-10-705 MODEL GUESTROOM 5036 VANITY DETAILS I-11-001 MODEL CORRIDOR DEMO PLAN 5036 I-11-101 MODEL CORRIDOR FURNITURE PLAN 5036 I-11-201 MODEL CORRIDOR ARCHITECTURAL PLAN 5036 I-11-301 MODEL CORRIDOR REFLECTED CEILING PLAN 5036 I-11-401 MODEL CORRIDOR POWER & DATA PLAN 5036 I-11-501 MODEL CORRIDOR FLOOR FINISH PLAN 5036 I-11-601 MODEL CORRIDOR ELEVATIONS 5036 I-11-602 MODEL CORRIDOR ELEVATIONS 5036 I-11-603 MODEL CORRIDOR ELEVATIONS 5036 I-11-604 MODEL CORRIDOR ELEVATIONS 5036 MECHANICAL M-100A ROOM 5036 MECHANICAL PLANS ELECTRICAL E-000A ELECTRICAL COVER SHEET 5036 E-001A ELECTRICAL SPECIFICATIONS 5036 E-002A ELECTRICAL SPECIFICATIONS 5036 E-100A ROOM 5036 ELECTRICAL PLANS E-102A MODEL CORRIDOR ELECTRICAL PLANS 5036 E-300A ELECTRICAL DIAGRAMS 5036 EL-100A ROOM 5036 LIGHTING PLANS EL-102 MODEL CORRIDOR LIGHTING PLANS 5036 06/21/18 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®3/28/2018 1:19:53 PM C:\Revit Local Files\116194.00_Four Seasons Vail__A17_GR and Corridor Permit Set_kadams.rvt 3" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/03/28 ISSUE FOR BUILDING PERMIT SPECIFICATIONS 6103 &5036 G-100 FOUR SEASONS RESORT AT VAIL OZ 06/21/18 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®3/28/2018 1:19:55 PM C:\Revit Local Files\116194.00_Four Seasons Vail__A17_GR and Corridor Permit Set_kadams.rvt 3" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/03/28 ISSUE FOR BUILDING PERMIT SPECIFICATIONS 6103 &5036 G-101 FOUR SEASONS RESORT AT VAIL OZ 06/21/18 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®3/28/2018 1:19:56 PM C:\Revit Local Files\116194.00_Four Seasons Vail__A17_GR and Corridor Permit Set_kadams.rvt 3" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/03/28 ISSUE FOR BUILDING PERMIT SPECIFICATIONS 6103 &5036 G-102 FOUR SEASONS RESORT AT VAIL OZ 06/21/18 FOUR SEASONS VAIL MODEL GUESTROOM 5036 & MODEL CORRIDOR Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR I-00-000 16 JUNE 2017 INDEX COVER SHEET NTS @ 24x36 06/21/18 Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR I-00-001 16 JUNE 2017 INDEX GENERAL NOTES NTS @ 24x36 06/21/18 XX-XX-XX UNLESS OTHERWISE NOTED SS S S S S S S +0'-0" GYP. BD. 101 01 01 SCALE: 1 VIEW NAME 1'-0" = 1'-0" 01 XX-XX 01 XX-XX Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR I-00-002 16 JUNE 2017 INDEX SYMBOLS NTS @ 24x36 06/21/18 INDEX COVER SHEET INDEX DRAWING NUMBER DESCRIPTION SCALE DRAWING LOG - GUEST AREAS ISSUE DATE I-00-000 I-00-001 INDEX GENERAL NOTES MODEL GUESTROOM 5036 I-10-001 MODEL GUESTROOM 5036 DEMO PLAN 16 JUNE 20171/4" = 1'-0" 06/16/17 06/16/17 I-00-002 I-00-003 INDEX SYMBOLS INDEX DRAWING LOG I-10-101 I-10-201 I-10-301 I-10-401 I-10-501 I-10-601 I-10-602 MODEL GUESTROOM 5036 FURNITURE PLAN MODEL GUESTROOM 5036 REFLECTED CEILING PLAN MODEL GUESTROOM 5036 ARCHITECTURAL PLAN MODEL GUESTROOM 5036 POWER & DATA PLAN MODEL GUESTROOM 5036 FLOOR FINISH PLAN MODEL GUESTROOM 5036 ELEVATIONS MODEL GUESTROOM 5036 ELEVATIONS 1/4" = 1'-0" 06/16/17 1/4" = 1'-0" 06/16/17 1/4" = 1'-0" 06/16/17 1/4" = 1'-0" 06/16/17 1/4" = 1'-0" 06/16/17 1/2" = 1'-0" 06/16/17 1/2" = 1'-0" 06/16/17 I-11-001 MODEL CORRIDOR DEMO PLAN 06/16/17 I-11-101 I-11-201 I-11-301 I-11-401 I-11-501 I-11-601 MODEL CORRIDOR FURNITURE PLAN MODEL CORRIDOR REFLECTED CEILING PLAN MODEL CORRIDOR ARCHITECTURAL PLAN MODEL CORRIDOR POWER & DATA PLAN MODEL CORRIDOR FLOOR FINISH PLAN MODEL CORRIDOR ELEVATIONS 06/16/17 06/16/17 06/16/17 06/16/17 06/16/17 06/16/17 06/16/17 06/16/17 06/16/17 1/8" = 1'-0" 1/8" = 1'-0" 1/8" = 1'-0" 1/8" = 1'-0" 1/8" = 1'-0" 1/8" = 1'-0" 1/2" = 1'-0" MODEL CORRIDOR I-11-602 MODEL CORRIDOR ELEVATIONS 06/16/171/2" = 1'-0" I-10-603 MODEL GUESTROOM 5036 ELEVATIONS 1/2" = 1'-0" 06/16/17 I-11-603 MODEL CORRIDOR ELEVATIONS 06/16/171/2" = 1'-0" I-11-604 MODEL CORRIDOR ELEVATIONS 06/16/171/2" = 1'-0" NTS NTS NTS NTS I-10-701 MODEL GUESTROOM 5036 MINIBAR DETAILS VARIES 06/16/17 I-10-705 MODEL GUESTROOM 5036 VANITY DETAILS VARIES 06/16/17 I-10-702 MODEL GUESTROOM 5036 CLOSET DOOR DETAILS VARIES I-10-703 MODEL GUESTROOM 5036 DRAPERY DETAILS VARIES I-10-704 MODEL GUESTROOM 5036 FIREPLACE DETAILS VARIES 30 JUNE 2017DRAWING NUMBER DESCRIPTION SCALE ISSUE DATE14 JULY 201707/14/17 07/14/17 07/14/17 21 JULY 201728 JULY 2017Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR I-00-003 16 JUNE 2017 INDEX DRAWING LOG NTS @ 24x36 30 JUNE 2017 14 JULY 2017 21 JULY 2017 06/21/18 NOTES: ENTRY CLOSET STAIN OR PAINT EXISTING WALL BASE. STAIN OR PAINT EXISTING ENTRY DOOR AND FRAME (BOTH SIDES). STAIN OR PAINT EXISTING BATHROOM SLIDING DOOR AND FRAME. NEW HANDLE ON BATHROOM DOOR. REMOVE EXISTING MINIBAR MILLWORK, TO BE REPLACED WITH NEW DESIGN WITH DRAWER FRIDGE. REMOVE EXISTING MINIBAR COUNTER TOP AND BACK SPLASH, TO BE REPLACED WITH NEW STONE. STAIN OR PAINT EXISTING CLOSET DOOR FRAME. REPLACE CLOSET DOORS WITH NEW DESIGN. STAIN OR PAINT EXISTING CLOSET MILLWORK. REPLACE EXISTING WOOD FLOOR WITH NEW. REMOVE CEILING TRIM AND EXISTING WALL COVERING. REFINISH WALL/ CEILING. INSTALL NEW WALL COVERING. REMOVE EXISTING WALL HOOKS AND REPLACE WITH NEW. REMOVE EXISTING DECORATIVE CEILING LIGHT FIXTURE AND REPLACE WITH NEW. NEW HARDWARE TO BE INSTALLED ON ENTRY DOOR AND BATHROOM SLIDING DOOR. BEDROOM REMOVE CEILING TRIMS, REFINISH WALL/ CEILING. REMOVE CORNER WALL TRIMS, REFINISH WALL. INSTALL NEW WALL COVERING. STAIN OR PAINT EXISTING WALL BASE AND OPENING TRIMS. REMOVE EXISTING STONE BASE AND CLADDING, WOODEN SHELF AND TRIMS ABOVE FIREPLACE. RE-CLAD FIREPLACE WALL WITH NEW STONE AND FRAMEWORK AND STONE BASE, ADD NEW WOODEN SHELF. DOOR/ WINDOW FRAME TO BE REFINISHED TO BLACK. NEW LIGHTING CONTROL, EVERYTHING TO BE CONTROLLED FROM THE BED (LIGHTING/ DRAPERY/ NIGHT LIGHT/ FIREPLACE/ DO NOT DISTURB/ MAKE UP ROOM) IF POSSIBLE, AND DIMMABLE. REMOVE EXISTING DRAPERY AND VALANCE. TO BE REPLACED WITH MOTORIZED DRAPERY AND ARCHITECTURAL VALANCE. EXISTING ELECTRICAL POINT BY CURRENT DESK TO BE MOVED TO THE TV WALL BEHIND NEW MILLWORK. NEW HEADBOARD TO HAVE INTEGRATED READING LIGHT, SCONCES, OUTLETS AND LIGHTING CONTROLS; MOVE/ ADD SOCKETS ON THE WALL BEHIND NEW HEADBOARD ACCORDINGLY. REMOVE EXISTING DECORATIVE CEILING LIGHT FIXTURE AND REPLACE WITH NEW. REMOVE EXISTING CARPET AND PADDING, REPLACE WITH NEW. REMOVE AND DISCARD ALL EXISTING FURNITURE. BATHROOM REMOVE DOUBLE CEILING TRIMS, REFINISH WALL/ CEILING. INSTALL NEW WALL COVERING. REMOVE EXISTING VANITY MILLWORK, STONE TOP AND BACK SPLASH. TO BE REPLACED WITH NEW VANITY MILLWORK, SINK, COUNTER TOP AND BACK SPLASH. REMOVE EXISTING DECORATIVE MIRROR, TO BE REPLACED WITH ELECTRIC MIRROR. PROVIDE J-BOX ACCORDINGLY. NEW MIRROR TO BE HARDWIRED AND CONTROLLED FROM NEW DOUBLE SWITCH ON DIMMER AT BATHROOM ENTRY. EXISTING SHOWER HEAD TO BE RETROFIT WITH A NEW RAIN/ HAND SHOWER COMBO. REPLACE WALL SCONCES. RESTORE EXISTING PLUMBING FIXTURES AND BATHROOM ACCESSORIES. REPLACE AS NEEDED. REMOVE TOWEL RINGS AND GLASS SHELF @ VANITY REPAIR WALL AS NEEDED. RESTORE EXISTING STONE FLOOR AND WALLS AND RE-GROUT. 01 03 04 05 06 07 08 09 02 SCALE: 1 MODEL GUESTROOM 5036 - DEMO PLAN 1/4" = 1'-0" 15 13 02 16 17 18 19 20 21 22 23 24 25 26 28 29 30 31 03 04 05 06 07 08 09 10 11 12 01 14 14 32 33 34 36 27 35 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 28 29 30 31 32 33 34 35 27 36 Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR I-10-001 16 JUNE 2017 MODEL GUESTROOM 5036 DM PLAN DEMO AS SHOWN @ 24x36 06/21/18 ART @ TUB 10-ART-04 ART @ CLOSET 10-ART-01 DINING CHAIR 10-SG-05 DESK LAMP 10-LT-07 DINING TABLE 10-CG-09 ART @ NICHE 10-ART-03 CONSOLE 10-CG-08 BED CEILING 10-LT-02 TV WALL 10-CG-06 CREDENZA 10-CG-07 CARPET 10-CPT-01 ROUND NIGHTSTAND10-CG-03 BED WALL SCONCE10-LT-04 READING LAMP10-LT-05 KING HEADBOARD10-CG-01 KING BED BASE10-CG-02 REC. NIGHTSTAND10-CG-04 LOUNGE CHAIR10-SG-04 COFFEE TABLE10-CG-05 ART @ CHAISE10-ART-02 LEFT CHAISE10-SG-02 OTTOMAN10-SG-03 FLOOR LAMP10-LT-06 DRAPERY 10-WT-01 OUTDOOR CHAIR 10-SG-06 OUTDOOR TABLE 10-CG-12 SCALE: 1 MODEL GUESTROOM 5036 - FURNITURE PLAN 1/4" = 1'-0" BATH CEILING 10-LT-03 BACK LIT MIRROR 10-MR-01 BATH SCONCE 10-LT-08 ENTRY CEILING10-LT-01 VANITY LIGHT 10-CG-10 CLOSET BENCH 10-SG-01 ENTRY CLOSET BEDROOM BATHROOM VANITY DARK 10-CG-11 16 JUNE 2017 Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 FN PLAN FURNITURE I-10-101 AS SHOWN @ 24x36 06/21/18 EXISTING TOILET EXISTING TUB & TUB FILLER & GRAB BAR NEW RETROFIT HAND SHOWER/ RAIN SHOWER COMBO, EXISTING SHOWER VALVE P-02 MINIBAR FIREPLACE DRAPERY SCALE: 1 MODEL GUESTROOM 5036 - ARCHITECTURAL PLAN 1/4" = 1'-0" CLOSET DOORS NEW BASIN, EXISTING FAUCETP-01 TOILET PAPER HOLDER BA-01 SPARE TP HOLDER BA-02 EXISTING TOWEL RAILS ROBE HOOK x 2BA-03 8"VANITY Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 AR PLAN ARCHITECTURAL I-10-201 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 8'-0" AFF PT-01 8'-5" AFF PT-02 SCALE:1 MODEL GUESTROOM 5036 - REFLECTED CEILING PLAN 1/4" = 1'-0" 8'-0" AFF PT-01 9'-4" AFF PT-01 1'-0"7'-8 1/2" AFF PT-02 7'-8 1/2" AFF PT-02 CL OF DOOR EQEQ EQEQ EQ EQ CL OF DOOR 1'-8"1'-8"512 "9'-2"7'-81 2" CL OF DOOR CL OF WALL 7'-0" AFF SF-01 1'-2" 1'-2"NOTES: -LIGHTING TO BE CONFIRMED & COORDINATED WITH LIGHTING DESIGNER Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 RC PLAN REFLECTED CEILING PLAN I-10-301 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 SCALE: 1 MODEL GUESTROOM 5036 - POWER & DATA PLAN 1/4" = 1'-0" PROVIDE POWER FOR BACK LIT MIRROR CL OF VANITY J 6"EXISTING J-BOX FOR WALL SCONCE @ 72" H JJ EXISTING J-BOX FOR WALL SCONCE PROVIDE POWER BELOW VANITY FOR NIGHTLIGHT EXISTING J-BOX FOR CEILING FIXTURE WALL MOUNTED FIXTURE ABOVE DOOR - QUAD OUTLET (READING LIGHT + WALL SCONCE @ 12" H ) - J-BOX FOR CONVENIENCE OUTLET @ 12" H - TERMINATED 3' WHIP WITH A QS CONNECTOR PHONE OUTLET @ 12" H QUAD OUTLET (DESK LAMP + MEDIA PLATE + NICHE) @ 12" H TV OUTLET @ 4'-2" H DATA OUTLET @ 4'-2" H D 10"1'-612"9'-312" 4'-812"5'-9"J J GFI GFI J-BOX , PROVIDE POWER FOR MOTORIZED DRAPERY J J J PROVIDE POWER FOR LIGHTING @ SHELF 1'-0"6"5" LIGHT SCENES @ 42" H HD-102 THERMOSTAT @ 60" H HD-103 DUPLEX OUTLET @ 12" H (FLOOR LAMP)HD-105 CONTROL PANEL + CONVENIENCE OUTLETHD-104L GFI OUTLETHD-107 GFI OUTLETHD-107 JEXISTING J-BOX FOR MAGNIFYING MIRROR @ 60" H J-BOX FOR MAKEUP PLATE INTEGRATED IN NEW SIGNAGEHD-100 CONTROL PANEL + CONVENIENCE OUTLETHD-104R ON/OFF SWITCH + DND + MAKE UP + ALL OFF @ 42" HHD-101 LIGHT SCENES + NIGHT LIGHT @ 52" HHD-106 J3'-5"1'-3"1'-0"DUPLEX OUTLET ABOVE COUNTER @ 42" H FOR KETTLE & COFFEE MACHINEHD-105 DUPLEX @ 12" H CLEANING HD-105 J J JAMB SWITCH VANITY MIRROR TO BE ANTI-FOG DND @ 42" H HD-108 5"- QUAD OUTLET (READING LIGHT + WALL SCONCE @ 12" H ) - J-BOX FOR CONVENIENCE OUTLET @ 12" - TERMINATED 3' WHIP WITH A QS CONNECTOR - PHONE OUTLET @ 12" H J J NOTES: -ALL ELECTRICAL REQUIREMENTS TO BE CONFIRMED & COORDINATED WITH M&E CONSULTANT -ALL COVER PLATES AND DEVICES TO BE REPLACED WITH NEW. CONTROL PANEL TO PROVIDE - LIGHT SCENES - ALL OFF BUTTON - NIGHTLIGHT (MINIBAR + UNDERVANITY) - MOTORIZED SHEER - MOTORIZED DRAPERY - ON/ OFF FIREPLACE - CONVENIENCE DUPLEX & USB Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 PD PLAN POWER & DATA I-10-401 AS SHOWN @ 24x36 16 JUNE 2017 14 JULY 2017 21 JULY 2017 06/21/18 7" PLANK, RANDOM LENGTH WF-01 SCALE: 1 MODEL GUESTROOM 5036 - FLOOR FINISH PLAN 1/4" = 1'-0" CARPET BY FF&E EXISTING STONE TO BE REFINISHED THRESHOLDWF-01 EXISTING CONCRETE EXISTING STONE THRESHOLD FIRST PLANK Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 FF PLAN FLOOR FINISH I-10-501 16 JUNE 2017 AS SHOWN @ 24x36 14 JULY 2017 06/21/18 OPEN SCALE: 2 ELEVATION 1/2" = 1'-0" SCALE: 4 ELEVATION 1/2" = 1'-0"SCALE: 3 ELEVATION 1/2" = 1'-0" FINISHED CEILING +8'-0" SCALE: 1 ELEVATION @ ENTRY 1/2" = 1'-0" SF-01 CASING FINISHED FLOOR ±0'-0" SF-01 CASING SF-01 DOOR SF-01 BASE WD-01 MILLWORK GL-01 BACK PANELS WD-01 DOORGL-02 DOORS MT-03 TRIM FRAME & HANDLE OPEN ART PT-01 VALANCE SCALE: 6 ELEVATION 1/2" = 1'-0" SCALE: 7 ELEVATION 1/2" = 1'-0" SCALE:8 ELEVATION 1/2" = 1'-0" SCALE: 5 ELEVATION @ BEDROOM 1/2" = 1'-0" FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-4" WD-03 SHELF ST-02 STONE LEDGE SF-01 CASING SF-01 BASE SF-01 CASING SF-01 DOOR FRAME ST-03 TEXTURED STONE CLADDING FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-4" ART ART3'-6"SF-01 CASING 1'-0"5" 4'-2"1'-0"T.V 1'-0"5'-7"4" SF-01 DOOR SF-01 CASING 4" CL 3'-6"5"5'-0"6" GL-01 BACK WALL MT-03 BASE ST-01 COUNTER TOP MT-03 FRAME WALL10-WC-01 WALL10-WC-02 5"1'-0" 4'-2" 2'-6"3'-7" 1'-8" 2'-6"2"MT-01 BLACKENED STEEL PANEL AROUND OPENING 3'-512" 1'-6"OPEN MT-01 BASE ANGLED WALL CABINET HANDLEHD-03 NEW DOOR KNOBHD-01 NOTES: - REFER TO THE FIRST ELEVATION OF THE AREA FOR FINISHES. - ALL FINISHES ARE TYPICAL THROUGHOUT THE AREA UNLESS NOTED OTHERWISE. - REFER TO FIRST ELEVATION OF THE AREA FOR CEILING HEIGHTS. Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR I-10-601 AS SHOWN @ 24x36 16 JUNE 2017 14 JULY 2017 MODEL GUESTROOM 5036 ELEVATIONS 06/21/18 SF-01 MILLWORK SCALE: 2 ELEVATION 1/2" = 1'-0" SCALE:3 ELEVATION 1/2" = 1'-0" SCALE: 4 ELEVATION 1/2" = 1'-0"SCALE: 1 ELEVATION @ CLOSET 1/2" = 1'-0" FINISHED FLOOR ±0'-0" FINISHED CEILING +8'-0" CLOSET ROD SF-01 BASE SCALE: 5 ELEVATION @ BATHROOM 1/2" = 1'-0" SCALE:6 ELEVATION 1/2" = 1'-0" SCALE: 8 ELEVATION 1/2" = 1'-0"SCALE: 7 ELEVATION 1/2" = 1'-0" FINISHED FLOOR ±0'-0" FINISHED CEILING +8'-5" FINISHED FLOOR ±0'-0" ART OPEN OPEN SF-01 MILLWORK ART SF-01 DOOR FRAME SF-01 CASING GL-01 EXISTING MIRROR LOWER WALL : EXISTING STONE EXISTING FROSTED GLASS DOOR EXISTING STONE CASING LOWER WALL : EXISTING STONE GL-01 DOOR MT-03 TRIM FRAME & HANDLE SF-01 CASING J J JJ BACK LIT MIRROR BY FF&E5'-7"4"4" EXISTING TOWEL BARS ANGLED WALL ANGLED WALL ANGLED WALL ANGLED WALL FINISHED CEILING +8'-5"4'-4" J 5'-0"6'-0"WALL10-WC-01 UPPER WALL10-WC-03 ST-04 TOP & BACK SPLASH WD-01 CABINET & BASE (OPT.01) MT-01 FRAME SUPPORT 4'-2" 2'-8"WD-03 CABINET & BASE (OPT.02)4'-3" 3'-0"J 7'-734"J NEW DOOR KNOB HD-01 NEW CABINET KNOBHD-02 NOTES: - REFER TO THE FIRST ELEVATION OF THE AREA FOR FINISHES. - ALL FINISHES ARE TYPICAL THROUGHOUT THE AREA UNLESS NOTED OTHERWISE. - REFER TO FIRST ELEVATION OF THE AREA FOR CEILING HEIGHTS. Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR I-10-602 16 JUNE 2017 AS SHOWN @ 24x36 14 JULY 2017 MODEL GUESTROOM 5036 ELEVATIONS 06/21/18 SCALE: 1 ELEVATION @ BATHROOM 1/2" = 1'-0" SCALE:2 ELEVATION 1/2" = 1'-0" SCALE:3 ELEVATION 1/2" = 1'-0" SCALE:4 ELEVATION 1/2" = 1'-0" EXISTING STONE WALL SCALE: 5 ELEVATION @ BATHROOM 1/2" = 1'-0" SCALE:6 ELEVATION 1/2" = 1'-0" SCALE:7 ELEVATION 1/2" = 1'-0" SCALE:8 ELEVATION 1/2" = 1'-0" EXISTING GLASS DOOR EXISTING STONE BASE FINISHED FLOOR ±0'-0" FINISHED FLOOR ±0'-0" EXISTING FROSTED GLASS DOOR EXISTING STONE CASING EQ. EQ.2'-6"1'-0"8"3"CL FINISHED CEILING 7'-8 1/2" WALL10-WC-03 FINISHED CEILING 7'-8 1/2"3'-6"5" NOTES: - REFER TO THE FIRST ELEVATION OF THE AREA FOR FINISHES. - ALL FINISHES ARE TYPICAL THROUGHOUT THE AREA UNLESS NOTED OTHERWISE. - REFER TO FIRST ELEVATION OF THE AREA FOR CEILING HEIGHTS. Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 ELEVATIONS I-10-603 16 JUNE 2017 AS SHOWN @ 24x36 14 JULY 2017 06/21/18 3'-0"MINI BAR DRAWER MODEL : DM20 VENDOR : DOMETIC WEBSITE : WWW.DOMETIC.COM DRAWER FOR DRY GOODS EXISTING OPENING SCALE: 1 PLAN 3/4" = 1'-0" SCALE: 5 FRONT ELEVATION 3/4" = 1'-0" SCALE:6 SIDE SECTION 3/4" = 1'-0" LINE OF UPPER CABINET MINI BAR DRAWER BELOW 3'-0"83 4"1'-4" 5"114"1'-6" 10"12 "STONE TOP MINI BAR DRAWER 3'-2" EQ 1'-91 4"EQ 3'-0"12"1'-6"1'-43 4" CABINET INTERIOR DEPTH 1/4" THK. CLEAR GLASS CLEAR MIRROR BACK SPLASH PROVIDE PERFORATION FOR MINIBAR VENTILATION 5"1'-712"2'-6"31 2" 31 2"7'-0"SIDE & TOP IS 1/2"MT-03 METAL TRIM 1/2" THK.MT-03 EXTRA 1/4" THK. CLEAR GLASS DOORGL-02 DOOR FRAMEMT-03 CLEAR MIRROR BACK SPLASHGL-01 1 1/4" THICK STONE TOPST-01 MILLWORKWD-01 RECESSED METAL BASEMT-03 1/2" THK. CLEAR GLASS SHELF STONE TOP LINE OF ONE LARGE DRAWER WOOD PANEL FILLERSWD-03 NEW WOOD TRIMSF-01 SCALE: 2 UPPER CABINET PLAN SECTION 3/4" = 1'-0" ALIGN1'-6" 2'-6"7'-312"EQ.1'-534"312 "1 1/2" GAP, FIXING AS REQUIRED 1/4" MIRROR PANELS INLAYS UPPER CABINET CARCASSE 1/2" TIMBER PANELS FINISHED WALL BY OTHERS 2" DOWN LIGHTS ON CEILINGEQ.7"8"5" 834"1'-9"114"10" 1'-712 "12"DUPLEX OUTLET FIXED PANELS CLEAR MIRROR BACK SPLASH 1/2" THK. CLEAR GLASS SHELFGL-02 CABINET HANDLEHD-03 9"1"CLEAR SILICON BEAD U SHAPE METAL FRAME WITH FINGER PULL BOTTOM FRAME WD-011/2"1/4"1" SCALE: 8 DOOR FRAME DETAIL 1'-0" = 1'-0" 1/4" GLASS PANEL CLEAR SILICON DISC TO PREVENT NOISE 1/2" CLEAR GLASS BOTTOM PANEL ALIGN 3/4"3/4" SCALE: 7 COUNTER DETAIL 6" = 1'-0" 1 1/4" STONE TOP SUPPORT AS REQUIRED FINISHED, SOLID EDGE DRAWER FOR DRY GOODS UNDERMOUNT RUNNERS, SELF CLOSING 1/4"1 1/4"1/8" CHAMFER SCALE: 3 DETAIL 6" = 1'-0" FINISHED WALL BY OTHERS SUPPORT AS REQUIRED 1/4" CLEAR GLASS PANEL WALL COVERING SF-01 WOODEN TRIM STONE SLAB 1/4"3 1/2" 1/2"1/4" CUSTOM DOOR PANEL FOR MINIBAR DRAWER 1/2" TIMBER PANEL WITH VENEER 1'-8" 9"2 1/4"SCALE: 9 DETAIL 6" = 1'-0" PAINTED CEILING PT-1 1/2" WOODEN CARCASSE SUPPORT AS REQUIRED WALL COVERING SF-01 WOODEN TRIM 1/2"1" 1/2" 1/4" GLASS PANEL ALIGN 5"3" FIXED TIMBER PANEL WITH VENEER SOLID EDGE METAL BASE, SUPPORT AS REQUIRED SCALE: 10 BASE DETAIL 6" = 1'-0"3 1/2"PERFORATED TIMBER PANEL FOR AIR RETURN 2 RECESSED DOWNLIGHTS BY LIGHTING DESIGNER 4 1/2" 2" T TYPE LA-002 TO REMOTE X-FORMER SEE ARCH. ELEC. DWGS FOR LOCATION, SIZE AND QUANTITY OF X-FORMER CL 1/2" 1" SCALE: 4 FRAME DETAIL 6" = 1'-0" FINISHED WALL BY OTHERS 1/2" FIXING AS REQUIRED SOLID WOOD BLOCKING WD-01 TIMBER PANEL FINISH ON EXPOSED SURFACES WD-01 UPPER CABINET CARCASSE 1/2" TIMBER 1/16" U SHAPE METAL FRAME 1/4" MIRROR PANEL 1/4" CLEAR GLASS PANEL 2"3/8"BACKING AS REQUIRED 1/4" CLEAR GLASS PANEL NOTES: - REFER TO ELEVATION DRAWINGS FOR FINISHES. - REFER TO AR PLAN FOR CORRECT ORIENTATION. Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 DETAILS MINIBAR I-10-701 AS SHOWN @ 24x36 16 JUNE 2017 14 JULY 2017 06/21/18 SCALE: 1 PLAN VIEW - CLOSET DOOR 3/4" = 1'-0" EXISTING FRAMEWORK TO BE REFINISHED FINISHED WALL BY OTHERS BASE RUNNING BELOW TO BE SITE VERIFIED EQ EQ SCALE: 5 ENTRY SIDE ELEVATION 3/4" = 1'-0" SCALE: 6 CLOSET SIDE ELEVATION 3/4" = 1'-0"3"2'-8"EXISTING CASING TO BE REFINISHEDSF-01 BLACK JAMB SWITCH FOR CLOSET LIGHT GC TO PROVIDE ROLLER CATCH @ THE TOP TO HOLD DOOR IN PLACE 1/8" FRAMEMT-03 DOORWD-01 HANDLE MT-03 SIM./OPP. DOORGL-01 3"EXISTING CASING TO BE REFINISHEDSF-01 1/8" FRAMEMT-03 TOP & BOTTOM PIVOTING MECHANISM.8"3'-0"FINISHED FLOOR +0'-0" FINISHED FLOOR +0'-0" BASEMT-03 BASEMT-03 HEIGHT TO BE SITE VERIFIEDHEIGHT TO BE SITE VERIFIED1/4" 1/4" 3/4"3"1 1/4" 1/4" CLEAR MIRROR PANEL, EASED EDGE BACKING AS REQUIRED 3/4" TIMBER PANEL WITH VENEER ON EXPOSED SURFACES 1/8" THICK METAL BASE SCALE: 4 BASE DETAIL 6" = 1'-0" 1/8"1 1/4"ALIGNED 3/4" TIMBER PANEL WITH VENEER ON EXPOSED SURFACES 1/4" CLEAR MIRROR PANEL, EASED EDGE BACKING AS REQUIRED 1/8" METAL FRAME EXISTING FRAMEWORK TO BE REFINISHED ALIGNED SCALE: 2 FRAME DETAIL 6" = 1'-0" 3/4"1/4"1/4"1 1/4" 1/4" CLEAR MIRROR PANEL, EASED EDGE BACKING AS REQUIRED 3/4" TIMBER PANEL WITH VENEER ON EXPOSED SURFACES 1/8"2 1/4"1/8"7/8"1/8" METAL TRIM SCALE: 3 HANDLE DETAIL 6" = 1'-0" 3/4"1/4"1/4"1 1/4" 1 1/2" NOTES: - ALL DIMENSIONS TO BE FIELD VERIFIED BASED ON EXISTING CONDITIONS Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 DETAILS CLOSET DOOR I-10-702 AS SHOWN @ 24x36 14 JULY 2017 06/21/18 SCALE: 1 PLAN VIEW 1/2" = 1'-0" 1" 2 RECESS MOUNTED MOTORS & TRACKS - 1X FOR SHEER CLOSE TO WINDOW - 1X FOR BLACKOUT DRAPERY QS DRAPERY SYSTEM BY LUTRON, LEFT DRAWN SCALE: 5 FRONT ELEVATION 1/2" = 1'-0" MOTORS TO BE HIDDEN BEHIND DRAPERY & VALANCE 11 1/4"1" 1" 1" 1'-0"3/4"WINDOW VALANCE METAL SIDE PANEL SCALE: 2 HEADER DETAIL 3" = 1'-0"4"3 4" 31 4"51 2" 31 4" 1'-0" PAINTED TIMBER PANEL CONCEALED SUPPORT AS REQUIRED CEILING MOUNTED TRACKS BY LUTRON Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 DETAILS DRAPERY I-10-703 AS SHOWN @ 24x36 14 JULY 2017 06/21/18 SCALE: 1 PLAN VIEW 3/4" = 1'-0" SCALE: 5 FRONT ELEVATION 3/4" = 1'-0" 3"9" 2'-5" 5"2"4'-0"TEXTURED STONE CLADDINGST-03 WOODEN SHELFWD-03 BLACKENED STEEL PANEL AROUND OPENINGMT-01 STONE LEDGEST-02 EXISTING GAS FIREPLACE HEARTH TO BE REFINISH IN BLACK HIDDEN LINE DENOTES THE WOODEN SHELF ABOVE 9'-4"1/2" STONE CLADDING 1/8" METAL PANEL STONE LEDGE 1/8" METAL PANELMT-01 1'-0"ANGLED ANGLED1'-012"2"3" 9"1'-0" SCALE: 4 LEDGE / BASE DETAIL 3" = 1'-0" EXISTING HEARTH TO BE REFINISH IN BLACK INSIDE 3/4" STONE SLAB WITH MITER CORNER & EASED EDGE SUPPORT AS REQUIRED BLACKENED STEEL BASE NOTES: - REFER TO ELEVATION DRAWINGS FOR FINISHES. - ALL DIMENSIONS TO BE FIELD VERIFIED BASED ON EXISTING CONDITIONS. - REFER TO AR PLAN FOR CORRECT ORIENTATION. 4"2"1 1/2" SUPPORT AS REQUIRED UPPER STONE CLADDING ACRYLIC DIFFUSER TO BE REMOVABLE. DIFFUSER MEDIA (TO BE PROVIDED BY OTHERS) CONSIST OF (1) 1/8" THICK LINEAR SPREAD LENS (PATTERN LINE TO BE PERPENDICULAR TO WALL) LED STRIP BY LIGHTING DESIGNER INTERIOR OF MILLWORK BOX TO BE FULLY FINISHED AND PAINTED MATTE WHITE EQUAL TO BENJAMIN MOORE SIMPLY WHITE (# OC-117) LIVE EDGE WOODEN SHELF METAL CLADDING SCALE: 3 WOODEN SHELF DETAIL 6" = 1'-0" FINISHED WALL BY OTHERS CONCEALED SUPPORT AS REQUIRED 1/8" METAL PANEL 1/2" STONE CLADDING SCALE: 2 SURROUND DETAIL 6" = 1'-0" 10 1/2"T 1"MIN.TO REMOTE X-FORMER SEE ARCH. ELEC. DWGS FOR LOCATION, SIZE AND QUANTITY OF X-FORMER TYPE LT-003 CONCEALED SUPPORT AS REQUIRED ENING SCALE: 6 SIDE SECTION 3/4" = 1'-0" TEXTURED STONE CLADDINGST-03 STONE LEDGEST-02 EXISTING GAS FIREPLACE HEARTH TO BE REFINISH IN BLACK 1'-0" 2'-5"V.I.F.9'-4"Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 DETAILS FIREPLACE I-10-704 AS SHOWN @ 24x36 14 JULY 2017 06/21/18 SCALE: 3 DETAIL 6" = 1'-0"1 1/4"1/2" STONE SLAB SUPPORT AS REQUIRED 3/4" TIMBER PANEL, VENEER ON EXPOSED SURFACES 3/4" STONE SLAB, MITER CORNER, EASED EDGES FLAT CHAMFER 6" 2 1/2" 4" LED STRIP BY LIGHTING DESIGNER. CONCEALED CHASE FOR CABLE MANAGEMENT 3/4"1/2"1" T TO REMOTE X-FORMER SEE ARCH. ELEC. DWGS FOR LOCATION, SIZE AND QUANTITY OF X-FORMER BLOCKING AS REQUIRED (BY OTHERS) TYPE LT-104 NOTES: - REFER TO ELEVATION DRAWINGS FOR FINISHES. - REFER TO AR PLAN FOR CORRECT ORIENTATION. - ALL DIM TO BE FIELD VERIFIED. - VANITY TO BE MADE WITH SOLID WOOD, MARINE GRADE PLYWOOD OR MOISTURE RESISTANT MDF, WITH EXTERIOR GRADE POLYURETHANE FINISH. - ALL JOINTS MUST BE WATER TIGHT. - ALL SIDES, INCLUDING UNDERSIDE & EXPOSED EDGES MUST BE FINISHED. 5'-9" BACK LIT MIRROR BY OTHERS LINE OF STONE TRIM BELOW LINE OF BOTTOM SHELF2'-134"7'-0"712" 71 2" 71 2"712"4"1'-1"212"2'-7" CLEAR EQ. EQ. SCALE: 1 PLAN VIEW 3/4" = 1'-0" SCALE:2 PLAN SECTION 3/4" = 1'-0" FIXING AS REQUIRED WALL BY OTHERS 7'-0" 2'-134"GLASS FINISHSTONE COUNTER TOP WOOD MILLWORK FINISHED WALL BY OTHERS SCALE: 9 BASE DETAIL 6" = 1'-0"4 3/4" 3"7 3/4"WOOD WOOD PANELS 2" WOOD BASE SCALE: 5 FRONT ELEVATION 3/4" = 1'-0" 2" 2"434" 2'-4"114"3" OPEN TO BACK WOOD PANEL 2'-10"SCALE: 6 SIDE ELEVATION 3/4" = 1'-0" STONE COUNTER TOP STONE BACKSPLASH WOOD BASE & SELF WOOD MILLWORK 734"2'-214"2'-10"3"OPEN SCALE: 7 SIDE SECTION 3/4" = 1'-0"2'-234"714"2'-10"3"STONE COUNTER TOP 3/4" NEW STONE BACKSPLASH 3/4" THICK EXISTING STONE TRIM, V.I.F. 3/8" THICK EXISTING STONE TILE WOOD CABINET EXISTING WALL TILE TO REMAIN EXISTING FAUCET FLAT METAL SUPPORT BEYOND 2" W x 1/4" THICK WOOD MILLWORK (OPT. 1)WD-01 COUNTER TOPST-04 BACKSPLASHST-04 WOOD BASE (OPT. 1)WD-01 FINISHED WALL BY OTHERS 1 2" 2'-1" OPEN 21 2" WOOD BASE (OPT. 2)WD-03 WOOD MILLWORK (OPT. 2)WD-03 2" W x 1/4" THICK FLAT METAL SUPPORTMT-01 TOWEL BARMT-01 Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL GUESTROOM 5036 DETAILS VANITY I-10-705 AS SHOWN @ 24x36 16 JUNE 2017 14 JULY 2017 06/21/18 SCALE: 1 MODEL CORRIDOR - DEMO PLAN 1/8" = 1'-0" 01 02 03 04 05 06 0708 09 NOTES: REMOVE CEILING TRIM AND EXISTING WALL COVERING. REFINISH WALL/ CEILING. STAIN OR PAINT EXISTING WALL BASE AND OPENING TRIMS. STAIN OR PAINT EXISTING DOORS AND FRAME. INSTALL NEW WOOD ACCENT TRIM. INSTALL NEW WALL COVERING. REPLACE WALL SCONCES. REPLACE DECORATIVE CEILING LIGHT FIXTURE. REMOVE EXISTING CARPET AND PADDING, REPLACE WITH NEW. LIGHTING DESIGNER TO RECOMMEND ABOUT NEW DOWNLIGHTS OR NOT. 01 03 04 05 06 07 08 09 02 Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL CORRIDOR DM PLAN DEMO I-11-001 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 SCONCE 11-LT-02 CEILING FIXTURE11-LT-01 CORRIDOR SET 11-ART-01 SCALE: 1 MODEL CORRIDOR - FURNITURE PLAN 1/8" = 1'-0" VESTIBULE SET11-ART-04 VESTIBULE SET11-ART-03 VESTIBULE SET11-ART-06 VESTIBULE SET11-ART-05 VESTIBULE SET 11-ART-03 VESTIBULE SET11-ART-04 VESTIBULE SET11-ART-06 CONSOLE 11-CG-01 CORRIDOR END 11-ART-02 TABLE LAMP 11-LT-03 CARPET 11-CP-01 CORRIDOR VESTIBULE VESTIBULE VESTIBULE VESTIBULE VESTIBULE Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL CORRIDOR FN PLAN FURNITURE I-11-101 16 JUNE 2017 AS SHOWN @ 24x36 21 JULY 2017 06/21/18 SCALE: 1 MODEL CORRIDOR - ARCHITECTURAL PLAN 1/8" = 1'-0" Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL CORRIDOR AR PLAN ARCHITECTURAL I-11-201 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 9'-0" AFF PT-01 9'-0" AFF PT-01 9'-0" AFF PT-01 SCALE: 1 MODEL CORRIDOR - REFLECTED CEILING PLAN 1/8" = 1'-0" 7'-6" AFF PT-01 NOTES: -LIGHTING TO BE CONFIRMED & COORDINATED WITH LIGHTING DESIGNER Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL CORRIDOR RC PLAN REFLECTED CEILING PLAN I-11-301 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 SCALE: 1 MODEL CORRIDOR - POWER & DATA PLAN 1/8" = 1'-0" J J J J JJ J J EXISTING J-BOX FOR CEILING FIXTURE EXISTING J-BOX FOR WALL SCONCEEXISTING J-BOX FOR WALL SCONCE JJ J J J J-BOX FOR MAKEUP PLATE INTEGRATED IN NEW SIGNAGEHD-100 J-BOX FOR MAKEUP PLATE INTEGRATED IN NEW SIGNAGE HD-100 JJ JJ JJ J NOTES: -ALL ELECTRICAL REQUIREMENTS TO BE CONFIRMED & COORDINATED WITH M&E CONSULTANT Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL CORRIDOR PD PLAN POWER & DATA I-11-401 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 SCALE: 1 MODEL CORRIDOR - FLOOR FINISH PLAN 1/8" = 1'-0" CARPET BY FF&E Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL CORRIDOR FF PLAN FLOOR FINISH I-11-501 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 NOTES: - REFER TO THE FIRST ELEVATION OF THE AREA FOR FINISHES. - ALL FINISHES ARE TYPICAL THROUGHOUT THE AREA UNLESS NOTED OTHERWISE. - REFER TO FIRST ELEVATION OF THE AREA FOR CEILING HEIGHTS. ART OPEN SCALE: 2 ELEVATION 1/2" = 1'-0" SCALE: 1 ELEVATION @ VESTIBULE 1/2" = 1'-0" FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" SF-01 CASING SF-01 BASE SF-01 CASING SF-01 DOOR ARTART ART ART SF-01 BASE FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" WALL 11-WC-01 WALL11-WC-01 5'-114"2'-0"3'-0" 2'-1"4"2'-1"TRUE LENGTH TRUE LENGTH TRUE LENGTH TRUE LENGTH Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL CORRIDOR ELEVATIONS I-11-601 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" J J ARTART SF-01 BASE FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" J J ART SF-01 VERTICAL BAND, 3" WIDE SF-01 VERTICAL BAND, 3" WIDE SF-01 BASE SF-01 CASING SF-01 DOOR SF-01 BASE ART J-BOX @ EXISTING HEIGHT 6'-0"SCALE: 1 ELEVATION @ CORRIDOR 1/2" = 1'-0" SCALE: 1 ELEVATION @ CORRIDOR 1/2" = 1'-0" SCALE: 1 ELEVATION @ CORRIDOR 1/2" = 1'-0"3'-1" 3'-1" WALL 11-WC-01 WALL 11-WC-01 WALL11-WC-01 4'-2" 4'-2"J-BOX @ EXISTING HEIGHT 6'-0"3'-1" 4'-2"3'-1" 4'-2"EQ. EQ. EQ. EQ. EQ. EQ. NOTES: - REFER TO THE FIRST ELEVATION OF THE AREA FOR FINISHES. - ALL FINISHES ARE TYPICAL THROUGHOUT THE AREA UNLESS NOTED OTHERWISE. - REFER TO FIRST ELEVATION OF THE AREA FOR CEILING HEIGHTS. Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL CORRIDOR ELEVATIONS I-11-602 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 JJ OPEN OPEN OPEN SCALE: 1 ELEVATION @ CORRIDOR 1/2" = 1'-0" SF-01 CASING SF-01 CASING SF-01 BASE SF-01 BASE FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" J J FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" OPEN SCALE: 1 ELEVATION @ CORRIDOR 1/2" = 1'-0" SCALE: 1 ELEVATION @ CORRIDOR 1/2" = 1'-0" SF-01 VERTICAL BAND, 3" WIDE SF-01 VERTICAL BAND, 3" WIDE SF-01 BASE J-BOX @ EXISTING HEIGHT 6'-0"SF-01 DOOR SF-01 CASING WALL11-WC-01 WALL11-WC-01 WALL11-WC-01 J-BOX @ EXISTING HEIGHT 6'-0"ANGLED WALL ANGLED WALL EQ EQ ANGLED WALL ANGLED WALL EQ EQ ANGLED WALL ANGLED WALL ANGLED WALL ANGLED WALL ANGLED WALL ANGLED WALLEQ EQ NOTES: - REFER TO THE FIRST ELEVATION OF THE AREA FOR FINISHES. - ALL FINISHES ARE TYPICAL THROUGHOUT THE AREA UNLESS NOTED OTHERWISE. - REFER TO FIRST ELEVATION OF THE AREA FOR CEILING HEIGHTS. Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL CORRIDOR ELEVATIONS I-11-603 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" OPEN SCALE: 1 ELEVATION @ VESTIBULE 1/2" = 1'-0" OPEN SCALE: 2 ELEVATION 1/2" = 1'-0" FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" OPEN SCALE: 4 ELEVATION 1/2" = 1'-0" SCALE: 3 ELEVATION 1/2" = 1'-0" FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" SCALE: 5 ELEVATION @ VESTIBULE 1/2" = 1'-0" FINISHED FLOOR ±0'-0" FINISHED CEILING +9'-0" SCALE: 7 ELEVATION 1/2" = 1'-0" OPEN OPEN SCALE: 8 ELEVATION 1/2" = 1'-0" SF-01 BASE SF-01 CASING SF-01 BASE SF-01 CASING SF-01 DOOR SF-01 CASING SF-01 DOOR SF-01 CASING SF-01 DOOR SCALE: 6 ELEVATION 1/2" = 1'-0" SF-01 VERTICAL BAND, 3" WIDE 3'-0" WALL11-WC-01 WALL11-WC-01 ARTART ART ART ARTART ART ART 2'-1" 4" 2'-1"3'-0" 2'-1"4"2'-1"TRUE LENGTH TRUE LENGTH TRUE LENGTH TRUE LENGTHTRUE LENGTHTRUE LENGTH NOTES: - REFER TO THE FIRST ELEVATION OF THE AREA FOR FINISHES. - ALL FINISHES ARE TYPICAL THROUGHOUT THE AREA UNLESS NOTED OTHERWISE. - REFER TO FIRST ELEVATION OF THE AREA FOR CEILING HEIGHTS. Issued For Scale Drawn By Drawing Title Drawing No. Project No. Issue Date No. Date Issued For NO USE, REPRODUCTION OR DISSEMINATION MAY BE MADE OF THIS DRAWING OR THE IDEAS, CONCEPTS, DESIGNS, SKETCHES, MODELS, SPECIFICATIONS, PROGRAMS, SOFTWARE, REPORTS OR OTHER INTANGIBLE DELIVERABLES AS SET FORTH HEREIN WITHOUT PRIOR WRITTEN CONSENT , COPYRIGHT 2015 VAIL 01702 DESIGN ARCHITECT NOT FOR CONSTRUCTION INTERIOR DESIGNER DEVELOPER Jeffrey Beers International 156 Fifth Ave, Penthouse 2 New York NY 10010 Tel: 212.352.2020 FOUR SEASONS RESIDENTIAL ARCHITECT INVESTOR MODEL CORRIDOR ELEVATIONS I-11-604 16 JUNE 2017 AS SHOWN @ 24x36 06/21/18 ENTRY CLOSET BEDROOM BATHROOM SCALE: 1 ROOM 5036 MECHANICAL PLAN 1/4" = 1'-0" DISCONNECT AND REMOVE EXISTING SINK BASIN AND REPLACE WITH KOHLER K-2330. REUSE EXISTING FAUCET AND ALL ACCESSORIES (TYPICAL OF 2). DISCONNECT AND REMOVE EXISTING SHOWER AND REPLACE WITH NEW SHOWER SET. REFER TO INTERIOR DESIGN DRAWINGS FOR PLUMBING FIXTURE SELECTION. REUSE EXISTING SHOWER VALVE AND PLUMBING. EXISTING PLUMBING FIXTURES TO REMAIN. 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. ALL SUBCONTRACTORS SHALL BE LICENSED, EXPERIENCED, AND THOROUGHLY KNOWLEDGEABLE IN THEIR RESPECTIVE AREAS OF THE CONSTRUCTION INDUSTRY AND SHALL PERFORM IN A RESPONSIBLE MANNER WITH ESTABLISHED CONSTRUCTION SEQUENCE, SHALL RECOGNIZE THE PRIORITY OF THE CONSTRUCTION DOCUMENTS, AND SHALL INFORM THE PRIME CONTRACTOR OF POTENTIAL PROBLEMS WHEN THE CONSTRUCTION DOCUMENTS ARE UNCLEAR OR INCONSISTENT. 3. SUBCONTRACTORS SHALL BE RESPONSIBLE TO NOTIFY THE PRIME CONTRACTOR OF DISCREPANCIES OR CONFLICTS IN THE CONSTRUCTION DOCUMENTS FOUND DURING BIDDING AND/OR PRIOR TO PERFORMING THE WORK. 4. EXAMINATION OF BIDDING DOCUMENTS. A. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS CAREFULLY, AND NOT LATER THAN SEVEN (7) DAYS PRIOR TO THE DATE OF RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO THE ARCHITECT FOR INTERPRETATION OR CORRECTION OF ANY DISCREPANCIES, AMBIGUITIES, INCONSISTENCIES, OR ERRORS THEREIN WHICH HE MAY DISCOVER. THE ARCHITECT WILL ISSUE ANY INTERPRETATION OR CORRECTION AS AN ADDENDUM. ONLY A WRITTEN INTERPRETATION OR CORRECTION BY ADDENDUM SHALL BE BINDING. NO BIDDER SHALL RELY UPON INTERPRETATIONS OR CORRECTIONS GIVEN BY ANY OTHER METHOD. IF DISCREPANCIES, AMBIGUITIES, INCONSISTENCIES, OR ERRORS ARE NOT COVERED BY ADDENDUM OR WRITTEN DIRECTIVE, CONTRACTOR SHALL INCLUDE IN HIS BID, LABOR MATERIALS AND METHODS OF CONSTRUCTION RESULTING IN HIGHER COST. AFTER AWARD OF CONTRACT, NO ALLOWANCE OR EXTRA COMPENSATION WILL BE MADE ON BEHALF OF THE CONTRACTOR DUE TO HIS FAILURE TO MAKE THE WRITTEN REQUESTS AS DESCRIBED ABOVE. B. FAILURE TO REQUEST CLARIFICATION DURING THE BID PERIOD OF ANY INADEQUACY, OMISSION, OR CONFLICT WILL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES. THE SIGNING OF THE CONTRACT WILL BE CONSIDERED AS IMPLICITLY DENOTING THAT THE CONTRACTOR HAS A THOROUGH COMPREHENSION OF THE FULL INTENT AND SCOPE OF THE CONSTRUCTION CONTRACT DRAWINGS AND SPECIFICATIONS. 5. PROVIDE A BASE BID WHICH SHALL INCLUDE ONLY SPECIFIED EQUIPMENT OR EQUIPMENT LISTED AS EQUIVALENT. NO SUBSTITUTIONS FOR THE LISTED EQUIPMENT SHALL BE ALLOWED IN THE BASE BID. 6. IN AS MUCH AS DESIGN FOR REMODEL AND/OR REHABILITATION REQUIRES THAT CERTAIN ASSUMPTIONS BE MADE REGARDING EXISTING CONDITIONS, AND BECAUSE SOME OF THESE ASSUMPTIONS CANNOT BE VERIFIED WITHOUT DESTROYING OTHERWISE ADEQUATE OR SERVICEABLE PORTIONS OF THE BUILDING, THE ENGINEER CANNOT ASSURE THE OWNER OR THE CONTRACTOR THAT THE PROFESSIONAL CONSULTING SERVICES HEREIN ENCOMPASS ALL CONTINGENCIES. FIELD COORDINATION DURING CONSTRUCTION IS IMPERATIVE. MAKE REASONABLE ALLOWANCES FOR UNSEEN CONDITIONS. 7. THE EXISTING BUILDING WILL BE OCCUPIED BY THE OWNER DURING CONSTRUCTION. CONTINUED OPERATION OF THE FACILITY SHALL NOT BE HINDERED BY THIS WORK. 8. IF NOT SPECIFICALLY DEFINED IN THESE CONSTRUCTION DOCUMENTS, MATERIALS AND/OR EQUIPMENT SHALL BE IDENTIFIED BY THE SUBCONTRACTOR WITH SUFFICIENT TIME TO ALLOW SELECTION, PURCHASE, AND DELIVERY TO MAINTAIN CONSTRUCTION SCHEDULE. 9. PROVIDE PLUMBING DEMOLITION AS REQUIRED. REFER TO INTERIOR DESIGN DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. EXISTING FIXTURES BEING REMOVED SHALL BE RETURNED TO THE OWNER. 10. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT, OWNER, AND ENGINEER. 11. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PERFORM HIS/HER WORK IN CONFORMANCE WITH ALL APPLICABLE CODES, ORDINANCES AND LIFE SAFETY FEATURES AS REQUIRED BY LOCAL, STATE, OR NATIONAL AUTHORITIES. THE CONTRACTOR SHALL VERIFY WITH THE ARCHITECT IF MODIFICATION OF HIS/HER WORK IS REQUIRED FOR COMPLIANCE. 12. ALL WORK OF ALL TRADES MUST BE IN STRICT COMPLIANCE, OR EXCEED THE MINIMUM MATERIAL AND METHOD REQUIREMENTS OF THE 2015 VERSION OF THE INTERNATIONAL BUILDING, MECHANICAL, PLUMBING, ENERGY CONSERVATION, AND FIRE CODES AND THE 2014 NATIONAL ELECTRICAL CODE, MOST CURRENT NFPA, ALL LOCAL ORDINANCES AND AMENDMENTS AND MANUFACTURER'S INSTALLATION RECOMMENDATIONS. IF A CONFLICT BETWEEN THOSE PUBLICATIONS EXISTS, THE MOST STRINGENT REQUIREMENT SHALL APPLY. 13. PAY FOR AND SECURE ALL REQUIRED PERMITS AND INSPECTIONS. PRIOR TO FINAL PAYMENT, TURN OVER TO ARCHITECT ALL CERTIFICATES OF COMPLETION. 14. WARRANTY THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. THE WARRANTY SHALL BE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 15. SUBMIT RECORD DOCUMENTS TO ARCHITECT. DOCUMENTS SHALL INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS, ALTERATIONS, REROUTINGS, ETC. 16. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION PRIOR TO ACCEPTANCE BY THE OWNER. 17. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. PERFORM AT A MINIMUM ALL CODE REQUIRED TESTS OR SYSTEMS. IF TESTS OF WORK ARE DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO ADDITIONAL COST TO OWNER. 18. ALL MATERIALS AND/OR EQUIPMENT SHALL BE HANDLED AND INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 19. REPAIR ALL ACCIDENTAL OR INTENTIONAL DAMAGE TO MATCH EXISTING CONSTRUCTION WITH NO NOTICEABLE DIFFERENCE IN CONTINUITY, APPEARANCE OR FUNCTION. MECHANICAL SPECIFICATIONS: PROJ. NO. DRAWN: CHECKED: DATE: SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® As indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 816578203.11 2018/03/28 ISSUE FOR BUILDING PERMIT FOUR SEASONS RESORT AT VAIL S:\BGPROJECTS\8203.11 VAIL FOUR SEASONS MODEL ROOM\DRAWINGS\ROOM 6103\8203.11M100.DWG03.28.188:07:16 AM ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 8203.11 Copyright 2018 BDS RSD ARK ROOM 5036 MECHANICAL PLANS M-100 06/21/18