Loading...
HomeMy WebLinkAboutB18-0107_Approved Calcs_1524856969.pdfPage 1 of 4 4/9/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233 /info@activeenergies.com) Site: Brownson Residence 2363 B Upper Traverse Way #22 Vail, CO 81657 Equipment: Panels: 15 Solaria PowerXT all black solar panels @ 330watts Inverter: 15 SolarEdge P370 Optimizers + 1 SolarEdge SE3800H-US inverter Mounting Equipment: Unirac all black racking system with DPW easy feet mounting feet Monitoring: SolarEdge Remote Energy Monitoring System System Layout: Single Panel = 5.32ft tall X 3.47ft wide Panel Arrangement: 2 rows of 5 on the north east facing roof; 1 row of 3/2 on the south west facing roof. All panels mounted flush to the roof. Holy Cross electric meter located on the east side of the home. Production meter to be located on the adjacent to the Holy Cross meter. Inverter to be located in the garage. Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Unit #22 Net Meter Production Meter Brownson Residence #22 Net Meter & Production Meter 04/27/18 Page 2 of 4 4/9/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Calculations 4.95kW System Size (STC) Panels: 15 Solaria PowerXT all black solar panels @ 330watts Inverter: 15 SolarEdge P370 Optimizers Inverter: SolarEdge SE3800H-US Inverter (1 string of 15 modules/optimizers) Array tilt angle: 14.04° Array azimuth: 30º/210º (where 180º is south) Estimated annual power production: 5,807kWh Maximum PV System Voltage: 690.7 Voc = 44.5V/module 44.5V x 1 module = 44.5V Temperature correction factor 690.7(A) Temperature Coefficient (Voc) = -0.32%/°C (-65C° x (-.0032C°)) = .208% ((.208% x 44.5V) x 1 panels) + 44.5V = 53.8V Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Isc = 9.49A 9.49A x 1.25 = 11.9A Maximum PV Output Circuit (Array) Current: 690.8 (A)(2) Max Inverter Input Circuit 10.5A Inverter Output Circuit Current: 690.8 (A)(3) 16A @ 240V 04/27/18 Page 3 of 4 4/9/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Conductor Sizing Roof Pass Thru Box to DC Disconnect/Inverter: Max Inverter Input Circuit 10.5A 10.5A x 125% = 13.1A 690.8 (B)(1) #10 THWN-2 Table 310.16 40A (75ºC column) Conduit fill adjustment Table 310.15 (B)(2)(a) No Conduit Fill Temperature correction factor Table 310.16 No Temperature correction factor From Inverter to AC Disconnect/Production Meter/Backfeed Point: Nameplate maximum continuous output current: 16A 16A x 125% = 20A #10 THWN-2 Table 310.16 30A (75ºC column) No Conduit fill adjustment Table 310.15 (B)(2)(a) No Temperature correction factor Table 310.16 Overcurrent Protection Devices 1 - 20A two pole breaker Backfeed Breaker Conductors may be oversized for Voltage Drop 04/27/18 Page 4 of 4 4/9/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com SolarEdge SE3800H-US Inverter w/ Integrated Disconnect NEMA 3R Max AC Output: 16A @ 240V With ARC Fault Protection & Rapid Shutdown compliant – in the garage DC Grounding Electrode Conductor solid bare #6 Cu, per NEC 250.66(C) Electric Panel Located in garage Line Diagram Brownson Residence 2363 B Upper Traverse Way #22 Vail, CO 81657 3.72 kW Utility Interactive Photovoltaic System Modules: 15 x Solaria PowerXT 330w solar panels Voc = 44.5V Isc = 9.49A Optimizers: 12 SolarEdge P370 1 String X 15 Modules/Optimizer Inverter: SolarEdge SE3800H-US Operating Voltage: 380V Operating Current: 9.83A Max System Voltage: 480V Max Output Current: 16A Tilt Angle: 14.04° Array Azimuth: 30°/210° Production: 5,807kWh/yr Notes: - See Calculation Sheet for conductor sizing. - All conductors are copper unless otherwise noted. - Inverter listed (UL-1741) to de- energize upon loss of utility voltage per NEC 690.61. - Inverter has integral ground-fault protection per NEC 690.5 - 240V 1 Phase Service Panel rating of 200A (bus rating 200 amp and 200 Main disconnect) to accommodate 20A (PV) + 200A (Main) = 220A supply (up to 120% of connected power sources from installations per NEC 705(D)(2)(3)(b) Net MeterPass Thru Box Located on Roof Placard stating ”Photovoltaic System Connected” 2 #10 PV Wire 1# 6G Bare Cu Conductors in Free Air Array mounted on roof 15 Solaria PowerXT 330w Solar Panels 15 SolarEdge P370 DC Optimizers 1 2 3 1215... ~80' ¾” C EMT/PVC 3 #12 THWN-2 1 #10 G THWN-2 Backfeed Breaker 20A 2P 240v ~50' ¾” EMT/MC Cable 2 #10 THWN-2 1 #10 G THWN-2 20A Production Meter Adjacent to net meter ~5' ¾” C EMT/PVC 3 #12 THWN-2 1 #10 G THWN-2 Net meter located on the north side of building 8 04/27/18 About Solaria Established in 2000, The Solaria Corporation has created one of the industry’s most respected IP portfolios, with over 100 patents encompassing materials, processes, applications, products, manufacturing automation and equipment. Headquartered in Fremont, California, Solaria has developed a technology platform that unlocks the potential of solar energy allowing it to be ubiquitous and universally accessed. Achieving over 19% efficiency, Solaria PowerXT solar modules are one of the highest power modules in the residential solar market. Compared to conventional modules, Solaria PowerXT modules have fewer gaps between the solar cells; this leads to higher power and superior aesthetics. Solaria PowerXT residential modules are manufactured with black backsheet and frames, giving them a striking appearance. Developed in California, Solaria’s patented cell cutting and module assembly form high-density sub-strings, which are packed more efficiently and reduce inactive space between cells. By utilizing a ribbon-less interconnection process, cells are cut and overlaid without soldering, which creates highly reliable sub-string assemblies in a cost effective manner. Higher Efficiency, Higher Power Solaria PowerXT modules achieve over 19% efficiency; conventional modules achieve 15% – 17% efficiency. Solaria PowerXT modules are one of the highest power modules available. Lower System Costs Solaria PowerXT modules produce more power per square meter area. This reduces installation costs due to fewer balance of system components. Improved Shading Tolerance Sub-strings are interconnected in parallel, within each of the four module quadrants, which dramatically lowers the shading losses and boosts energy yield. Improved Aesthetics Compared to conventional modules, Solaria PowerXT modules have a more uniform appearance and superior aesthetics. Durability and Reliability Solder-less cell interconnections are highly reliable and designed to far exceed the industry leading 25 year warranty. The Solaria Corporation 6200 Paseo Padre Parkway, Fremont, CA 94555 P: (510) 270-2500 www.solaria.com Copyright © 2017 The Solaria Corporation Product specifications are subject to change without notice. Rev 2G 1-26-2017 Solaria PowerXT™-330R-PX | Solaria PowerXT™-325R-BX Solaria PowerXT™ | Residential 04/27/18 The Solaria Corporation 6200 Paseo Padre Parkway, Fremont, CA 94555 P: (510) 270-2500 www.solaria.com Copyright © 2017 The Solaria Corporation Product specifications are subject to change without notice. Rev 2G 1-26-2017 Solaria PowerXT™-330R-PX Solaria PowerXT™-325R-BX Performance at STC (1000W/m2, 25° C, AM 1.5) Solaria PowerXT- 320R-BX 325R-BX 325R-PX 330R-PX Max Power (Pmax) [W] 320 325 325 330 Efficiency [%] 18.7 19.0 19.0 19.3 Open Circuit Voltage (Voc) [V] 44.3 44.5 44.3 44.5 Short Circuit Current (Isc) [A] 9.36 9.40 9.46 9.49 Max Power Voltage (Vmp) [V] 36.5 36.7 36.4 36.6 Max Power Current (Imp) [A] 8.77 8.86 8.93 9.02 Power Tolerance [%] -0/+3 -0/+3 -0/+3 -0/+3 Performance at NOCT (800W/m2, 20°C Amb, Wind 1 m/s, AM 1.5) Max Power (Pmax) [W] 235 239 239 243 Open Circuit Voltage (Voc) [V] 40.7 41.0 40.7 41.0 Short Circuit Current (Isc) [A] 7.54 7.58 7.63 7.66 Max Power Voltage (Vmp) [V] 33.2 33.4 33.1 33.3 Max Power Current (Imp) [A] 7.08 7.16 7.23 7.30 Temperature Characteristics NOCT [ºC] 45 +/-2 Temp. Coeff. of Pmax [% / ºC] -0.40 Temp. Coeff. of Voc [% / ºC] -0.32 Temp. Coeff. of Isc [% / ºC] 0.05 Design Parameters Operating temperature [ºC] -40 to +85 Max System Voltage [V] 1000 Max Fuse Rating [A] 15 Bypass Diodes [#] 4 Mechanical Characteristics Cell Type Monocrystalline Silicon Dimensions (L x W x H) 1621mm x 1056mm x 40mm Weight 20 kg / 44 lbs Glass Type / Thickness AR Coated, Tempered / 3.2mm Frame Type Anodized Aluminum Cable Type / Length 12 AWG PV Wire (UL) / 1000mm Connector Type Amphenol H4 (MC4 compatible) Junction Box IP67 / 4 diodes Front Load (UL 1703) 5400 Pa / 113 psf Rear Load (UL 1703) 3600 Pa / 75 psf Certifications / Warranty Certifications UL 1703/IEC 61215/IEC 61730/CEC Fire Type (UL 1703) 1 Power & Product Warranty 25 years* * Warranty details at www.solaria.com Packaging Stacking Method Horizontal / Palletized Pcs / Pallet 25 Pallet Dims 1668 x 1120 x 1254 mm Pallet Weight 560 kg / 1235 lbs Pallets / 40-ft Container 28 Pcs / 40-ft Container 700 1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 Authorized Dealer IV Curves vs. Irradiance (330W Module) 04/27/18 SolarEdge Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US INVERTERSwww.solaredge.usUSA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA Optimized installation with HD-Wave technology Specifically designed to work with power optmizers Record-breaking efficiency Integrated Arc Fault protecton and Rapid Shutdown for NEC 2014 and 2017, per artcle 690.11 and 690.12 Extremely small High reliability without any electrolytc capacitors Built-in module-level monitoring Outdoor and indoor installaton Optonal: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) 12-25 04/27/18 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2017. V.01. Subject to change without notice. Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US OUTPUT Rated AC Power Output 3000 3800 5000 6000 7600 VA Max. AC Power Output 3000 3800 5000 6000 7600 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) - - 3 - - Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 Vac AC Frequency (Nominal) 59.3 - 60 - 60.5(1) Hz Maximum Contnuous Output Current 208V - - 24 - - A Maximum Contnuous Output Current 240V 12.5 16 21 25 32 A GFDI Threshold 1 A Utlity Monitoring, Islanding Protecton, Country Configurable Thresholds Yes INPUT Maximum DC Power 4650 5900 7750 9300 11800 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - - 15.5 - - Adc Maximum Input Current 240V 8.5 10.5 13.5 16.5 20 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protecton Yes Ground-Fault Isolaton Detecton 600k Sensitvity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nightme Power Consumpton < 2.5 W ADDITIONAL FEATURES Supported Communicaton Interfaces RS485, Ethernet, ZigBee (optonal), Cellular (optonal) Revenue Grade Data, ANSI C12.20 Optonal(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatc Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connecton Standards IEEE1547, Rule 21(3), Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 0.75-1” Conduit / 14-6 AWG DC Input Conduit Size / # of Strings / AWG Range 0.75-1” Conduit /1-2 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in / mm Weight with Safety Switch 25.3 / 11.5 lb / kg Noise < 25 dBA Cooling Natural Convecton Operatng Temperature Range -13 to +140 / -25 to +60(4) (-40˚F / -40˚C opton)(5) ˚F / ˚C Protecton Ratng NEMA 3R (Inverter with Safety Switch) (1) For other regional setngs please contact SolarEdge support(2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) Pending certficaton(4) Power de-ratng from 50˚C(5) -40 version P/N: SExxxxH-US000NNU4 04/27/18 Page 1 of 4 4/9/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233 /info@activeenergies.com) Site: Davis Residence 2401 B Upper Traverse Way #16 Vail, CO 81657 Equipment: Panels: 14 Hanwha Q.PEAK DUO BLK-G5 all black solar panels @ 310watts Inverter: 14 SolarEdge P320 Optimizers + 1 SolarEdge SE3800H-US inverter Mounting Equipment: Unirac all black racking system with DPW easy feet mounting feet Monitoring: SolarEdge Remote Energy Monitoring System System Layout: Single Panel = 5.52ft tall X 3.28ft wide Panel Arrangement: 2 rows of 5 on the north facing roof and 1 row of 2/2 on the south facing roof; all panels mounted flush to the roof Holy Cross electric meter located on the north side of the building. Production meter to be located adjacent to the Holy Cross meter. Inverter to be located in the garage. Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Unit B Net Meter Production Meter Harwood Residence #16 Net Meter & Production Meter 04/27/18 Page 2 of 4 4/9/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Calculations 4.34kW System Size (STC) Panels: 14 Hanwha Q.PEAK DUO BLK-G5.1 all black solar panels @ 310watts Inverter: 14 SolarEdge P320 Optimizers Inverter: SolarEdge SE3000H-US Inverter (1 string of 14 modules/optimizers) Array tilt angle: 14.04° Array azimuth: 10º/190º (where 180º is south) Estimated annual power production: 4,972kWh Maximum PV System Voltage: 690.7 Voc = 40.02V/module 40.02V x 1 module = 40.02V Temperature correction factor 690.7(A) Temperature Coefficient (Voc) = -0.28%/°C (-65C° x (-.0028C°)) = .182% ((.182% x 40.02V) x 1 panels) + 40.02V = 47.3V Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Isc = 9.83A 9.83A x 1.25 = 12.3A Maximum PV Output Circuit (Array) Current: 690.8 (A)(2) Max Inverter Input Circuit 10.5A Inverter Output Circuit Current: 690.8 (A)(3) 16A @ 240V 04/27/18 Page 3 of 4 4/9/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Conductor Sizing Roof Pass Thru Box to DC Disconnect/Inverter: Max Inverter Input Circuit 10.5A 10.5A x 125% = 13.1A 690.8 (B)(1) #10 THWN-2 Table 310.16 40A (75ºC column) Conduit fill adjustment Table 310.15 (B)(2)(a) No Conduit Fill Temperature correction factor Table 310.16 No Temperature correction factor From Inverter to AC Disconnect/Production Meter/Backfeed Point: Nameplate maximum continuous output current: 16A 16A x 125% = 20A #10 THWN-2 Table 310.16 30A (75ºC column) No Conduit fill adjustment Table 310.15 (B)(2)(a) No Temperature correction factor Table 310.16 Overcurrent Protection Devices 1 - 20A two pole breaker Backfeed Breaker Conductors may be oversized for Voltage Drop 04/27/18 Page 4 of 4 4/9/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com SolarEdge SE3000H-US Inverter w/ Integrated Disconnect NEMA 3R Max AC Output: 12.5A @ 240V With ARC Fault Protection & Rapid Shutdown compliant – in the garage DC Grounding Electrode Conductor solid bare #6 Cu, per NEC 250.66(C) Electric Panel Located in garage Line Diagram Davis Residence 2401 B Upper Traverse Way #16 Vail, CO 81657 3.72 kW Utility Interactive Photovoltaic System Modules: 12 x Hanwha Q.PEAK DUO BLK-G5 310 Voc = 40.02V Isc = 9.83A Optimizers: 14 SolarEdge P320 1 String X 14 Modules/Optimizer Inverter: SolarEdge SE3800H-US Operating Voltage: 380V Operating Current: 9.83A Max System Voltage: 480V Max Output Current: 16A Tilt Angle: 14.04° Array Azimuth: 10°/190° Production: 4,972kWh/yr Notes: - See Calculation Sheet for conductor sizing. - All conductors are copper unless otherwise noted. - Inverter listed (UL-1741) to de- energize upon loss of utility voltage per NEC 690.61. - Inverter has integral ground-fault protection per NEC 690.5 - 240V 1 Phase Service Panel rating of 200A (bus rating 200 amp and 200 Main disconnect) to accommodate 20A (PV) + 200A (Main) = 220A supply (up to 120% of connected power sources from installations per NEC 705(D)(2)(3)(b) Net MeterPass Thru Box Located on Roof Placard stating ”Photovoltaic System Connected” 2 #10 PV Wire 1# 6G Bare Cu Conductors in Free Air Array mounted on roof 14 Hanwha Q.PEAK DUP BLK-G5 310 Solar Panels 14 SolarEdge P320 DC Optimizers 1 2 3 1214... ~80' ¾” C EMT/PVC 3 #12 THWN-2 1 #10 G THWN-2 Backfeed Breaker 20A 2P 240v ~50' ¾” EMT/MC Cable 2 #10 THWN-2 1 #10 G THWN-2 20A Production Meter Adjacent to net meter ~5' ¾” C EMT/PVC 3 #12 THWN-2 1 #10 G THWN-2 Net meter located on the north side of building 3 04/27/18 Monocrystalline PV Module SLA-M Monocrystalline 60 Cell 310 Wp  ENSURES MAXIMUM EFFICIENCY 60 of the highest efficiency, premium quality monocrystalline cells result in a maximum power rating of 310Wp.  ADVANCED PERFORMANCE WARRANTY 25-year linear power performance guarantee to 82%  ENHANCED PRODUCT WARRANTY 12-year product/workmanship warranty  BUILT BY INDUSTRY EXPERTS With over 35 years of industry experience, Silfab’s technical team are pioneers in PV technology and are dedicated to an innovative approach that provides superior manufacturing processes including: infra-red cell sorting, glass washing, automated soldering and meticulous cell alignment.  POSITIVE TOLERANCE (-0/+5W) All positive module sorting ensures maximum performance  44 PPM DEFECT RATE* Total automation ensures strict quality control during each step of the process at our certified ISO manufacturing facility. *As of December 31, 2016  LIGHT AND DURABLE Over-engineered to weather low load bearing structures up to 5400 Pa. Light-weight frame exclusively designed with wide-ranging racking compatibility and durability.  PID RESISTANT Proven in accordance to IEC 62804-1  AVAILABLE IN All Black 100% MAXIMUM POWER DENSITY Silfab’s SLA-M 310 ultra-high-efficiency modules are optimized for both Residential and Commercial projects where maximum power density is preferred. 100% NORTH AMERICAN QUALITY MATTERS Silfab’s fully-automated manufacturing facility ensures precision engineering is applied at every stage. Superior reliability and performance combine to produce one of the highest quality modules with the lowest defect rate in the industry. NORTH AMERICAN CUSTOMIZED SERVICE Silfab’s 100% North American based team leverages just-in-time manufacturing to deliver unparalleled service, on-time delivery and flexible project solutions. Los Angeles • Toronto • Minneapolis TARIFFFREE BAA ARRA JUST-IN-TIME PERFOR M ERTOP 04/27/18 Electrical Specifications SILFAB SLA Monocrystalline Test Conditions STC NOCT Module Power (Pmax) Wp 310 234 Maximum power voltage (Vpmax) V 33.05 29.7 Maximum power current (Ipmax) A 9.38 7.88 Open circuit voltage (Voc) V 40.25 37.2 Short circuit current (Isc) A 9.93 8.14 Module efficiency % 19.0 17.9 Maximum system voltage (VDC) V 1000 Series fuse rating A 15 Power Tolerance Wp -0/+5 Measurement conditions: STC 1000 W/m2 • AM 1.5 • Temperature 25 °C • NOCT 800 W/m² • AM 1.5 • Measurement uncertainty ≤ 3% • Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by ±5% and power by -0/+5W.SLA_M _300_ 01 • No reproduction of any kind is allowed. Data and information is subject to modifications without notice. ©Silfab, March 7, 2017.Temperature Ratings SILFAB SLA Monocrystalline Temperature Coefficient Isc %/K 0.03 Temperature Coefficient Voc %/K -0.30 Temperature Coefficient Pmax %/K -0.38 NOCT (± 2°C) °C 45 Operating temperature °C -40/+85 Mechanical Properties and Components SILFAB SLA Monocrystalline Module weight (± 1 kg) kg 19 Dimensions (H x L x D; ± 1mm) mm 1650 x 990 x 38 Maximum surface load (wind/snow)* N/m2 5400 Hail impact resistance ø 25 mm at 83 km/h Cells 60 - Si monocrystalline - 3 or 4 busbar - 156.75 x 156.75 mm Glass 3.2 mm high transmittance, tempered, antireflective coating Backsheet Multilayer polyester-based Frame Anodized Al Bypass diodes 3 diodes-45V/12A, IP67/IP68 Cables and connectors (See installation manual) 1200 mm ø 5.7 mm (4 mm2), MC4 compatible Certifications SILFAB SLA Monocrystalline Product ULC ORD C1703, UL 1703, IEC 61215, IEC 61730, IEC 61701, CEC listed UL Fire Rating: Type 2 (Type 1 on request) Factory ISO 9001:2008 Warranties SILFAB SLA Monocrystalline Module product warranty 12 years 25 years Linear power performance guarantee ≥ 97% end of 1st year ≥ 90% end of 12th year ≥ 82% end of 25th year CC 4007x12 (x4) Mounting Slot Grounding Hole Ø4.2 (x2) Grounding Hole Drainage (x8)127 10 C-C Profile View 3826 1.81200±15165038 850 958 All Dimensions in mm Tolerances: ±1mmHole tolerances: ±0.2mm Drawings not to scale 990 Third-party generated pan files from PV Evolution Labs available for download at: www.silfab.ca/downloads Warning: Read the installation and User Manual before handling, installing and operating modules.  Pallet Count: 26  Container Count: 936 Silfab Solar Inc. 240 Courtneypark Drive East • Mississauga, Ontario Canada L5T 2S5 Tel +1 905-255-2501 • Fax +1 905-696-0267 info@silfab.ca • www.silfab.ca 04/27/18 SolarEdge Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US INVERTERSwww.solaredge.usUSA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA Optimized installation with HD-Wave technology Specifically designed to work with power optmizers Record-breaking efficiency Integrated Arc Fault protecton and Rapid Shutdown for NEC 2014 and 2017, per artcle 690.11 and 690.12 Extremely small High reliability without any electrolytc capacitors Built-in module-level monitoring Outdoor and indoor installaton Optonal: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) 12-25 04/27/18 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2017. V.01. Subject to change without notice. Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US OUTPUT Rated AC Power Output 3000 3800 5000 6000 7600 VA Max. AC Power Output 3000 3800 5000 6000 7600 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) - - 3 - - Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 Vac AC Frequency (Nominal) 59.3 - 60 - 60.5(1) Hz Maximum Contnuous Output Current 208V - - 24 - - A Maximum Contnuous Output Current 240V 12.5 16 21 25 32 A GFDI Threshold 1 A Utlity Monitoring, Islanding Protecton, Country Configurable Thresholds Yes INPUT Maximum DC Power 4650 5900 7750 9300 11800 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - - 15.5 - - Adc Maximum Input Current 240V 8.5 10.5 13.5 16.5 20 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protecton Yes Ground-Fault Isolaton Detecton 600k Sensitvity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nightme Power Consumpton < 2.5 W ADDITIONAL FEATURES Supported Communicaton Interfaces RS485, Ethernet, ZigBee (optonal), Cellular (optonal) Revenue Grade Data, ANSI C12.20 Optonal(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatc Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connecton Standards IEEE1547, Rule 21(3), Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 0.75-1” Conduit / 14-6 AWG DC Input Conduit Size / # of Strings / AWG Range 0.75-1” Conduit /1-2 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in / mm Weight with Safety Switch 25.3 / 11.5 lb / kg Noise < 25 dBA Cooling Natural Convecton Operatng Temperature Range -13 to +140 / -25 to +60(4) (-40˚F / -40˚C opton)(5) ˚F / ˚C Protecton Ratng NEMA 3R (Inverter with Safety Switch) (1) For other regional setngs please contact SolarEdge support(2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) Pending certficaton(4) Power de-ratng from 50˚C(5) -40 version P/N: SExxxxH-US000NNU4 04/27/18 Page 1 of 4 4/10/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233 /info@activeenergies.com) Site: Hoerner Residence 2401 C Upper Traverse Way #15 Vail, CO 81657 Equipment: Panels: 12 Hanwha Q.PEAK DUO BLK-G5 all black solar panels @ 310watts Inverter: 12 SolarEdge P320 Optimizers + 1 SolarEdge SE3000H-US inverter Mounting Equipment: Unirac all black racking system with DPW easy feet mounting feet Monitoring: SolarEdge Remote Energy Monitoring System System Layout: Single Panel = 5.52ft tall X 3.28ft wide Panel Arrangement: see layout below; all panels mounted flush to the roof Holy Cross electric meter located on the north side of the building. Production meter to be located adjacent to the Holy Cross meter. Inverter to be located in the garage. Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Unit C Net Meter Production Meter Hoerner Residence #15 Net Meter & Production Meter 04/27/18 Page 2 of 4 4/10/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Calculations 3.72kW System Size (STC) Panels: 12 Hanwha Q.PEAK DUO BLK-G5.1 all black solar panels @ 310watts Inverter: 12 SolarEdge P320 Optimizers Inverter: SolarEdge SE3000H-US Inverter (1 string of 12 modules/optimizers) Array tilt angle: 14.04° Array azimuth: 10º/100º (where 180º is south) Estimated annual power production: 4,191kWh Maximum PV System Voltage: 690.7 Voc = 40.02V/module 40.02V x 1 module = 40.02V Temperature correction factor 690.7(A) Temperature Coefficient (Voc) = -0.28%/°C (-65C° x (-.0028C°)) = .182% ((.182% x 40.02V) x 1 panels) + 40.02V = 47.3V Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Isc = 9.83A 9.83A x 1.25 = 12.3A Maximum PV Output Circuit (Array) Current: 690.8 (A)(2) Max Inverter Input Circuit 8.5A Inverter Output Circuit Current: 690.8 (A)(3) 12.5A @ 240V 04/27/18 Page 3 of 4 4/10/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Conductor Sizing Roof Pass Thru Box to DC Disconnect/Inverter: Max Inverter Input Circuit 8.5A 8.5A x 125% = 10.6A 690.8 (B)(1) #10 THWN-2 Table 310.16 40A (75ºC column) Conduit fill adjustment Table 310.15 (B)(2)(a) No Conduit Fill Temperature correction factor Table 310.16 No Temperature correction factor From Inverter to AC Disconnect/Production Meter/Backfeed Point: Nameplate maximum continuous output current: 12.5A 12.A x 125% = 15.6A #10 THWN-2 Table 310.16 30A (75ºC column) No Conduit fill adjustment Table 310.15 (B)(2)(a) No Temperature correction factor Table 310.16 Overcurrent Protection Devices 1 - 20A two pole breaker Backfeed Breaker Conductors may be oversized for Voltage Drop 04/27/18 Page 4 of 4 4/10/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com SolarEdge SE3000H-US Inverter w/ Integrated Disconnect NEMA 3R Max AC Output: 12.5A @ 240V With ARC Fault Protection & Rapid Shutdown compliant – in the garage DC Grounding Electrode Conductor solid bare #6 Cu, per NEC 250.66(C) Electric Panel Located in garage Line Diagram Hoerner Residence 2401 C Upper Traverse Way #15 Vail, CO 81657 3.72 kW Utility Interactive Photovoltaic System Modules: 12 x Hanwha Q.PEAK DUO BLK-G5 310 Voc = 40.02V Isc = 9.83A Optimizers: 12 SolarEdge P320 1 String X 12 Modules/Optimizer Inverter: SolarEdge SE3000H-US Operating Voltage: 380V Operating Current: 9.83A Max System Voltage: 480V Max Output Current: 12.5A Tilt Angle: 14.04° Array Azimuth: 10°/100° Production: 4,191kWh/yr Notes: - See Calculation Sheet for conductor sizing. - All conductors are copper unless otherwise noted. - Inverter listed (UL-1741) to de- energize upon loss of utility voltage per NEC 690.61. - Inverter has integral ground-fault protection per NEC 690.5 - 240V 1 Phase Service Panel rating of 200A (bus rating 200 amp and 200 Main disconnect) to accommodate 20A (PV) + 200A (Main) = 220A supply (up to 120% of connected power sources from installations per NEC 705(D)(2)(3)(b) Net MeterPass Thru Box Located on Roof Placard stating ”Photovoltaic System Connected” 2 #10 PV Wire 1# 6G Bare Cu Conductors in Free Air Array mounted on roof 12 Hanwha Q.PEAK DUP BLK-G5 310 Solar Panels 12 SolarEdge P320 DC Optimizers 1 2 3 1212... ~80' ¾” C EMT/PVC 3 #12 THWN-2 1 #10 G THWN-2 Backfeed Breaker 20A 2P 240v ~50' ¾” EMT/MC Cable 2 #10 THWN-2 1 #10 G THWN-2 20A Production Meter Adjacent to net meter ~5' ¾” C EMT/PVC 3 #12 THWN-2 1 #10 G THWN-2 Net meter located on the north side of building 3 04/27/18 0121 03456® 814356129 ¯°± ²³´µ±¶®·¸¹º±»»®µ¼¶½»± ¾¿À¿ÁÂÃÄ¿®¿ÅÿÆÇ®ÈÉÄÈÊÁ¿É®ËÌÆÍÈÁ¿®Â¿ÎÂÌÆÃÊÏ ÐÑÒÓÔÕÖר®ÙÚÛÜÝÑÑÞÑ×ÜÐßÜàÚÝàáÑÐâÐÙÜãÙÑ äåæ®æçèéåèêçè æë®êåìíîç®èçîïðñïîïäò®óôåèçôðèì õö÷ø ùúûüý þÿĀāĂā㥮þÿąĄĆ®ĂÿćĄĆĈĉĊĄ ċù®ČčĎĎ ďÿĉÿĊĆĐĀĂĈććāĉĄ®ďÿđĒćĄ ēĔüĕĖėüý þÿąĄĆ®ÿĒĂþĒĂ®ĆĈĉĘĄ ėęĚēě ďĈĜāďĒﮥĝĝāĊāĄĉĊĐ ĞğğĠġĠĢģĤĥ®ĦĤĥħĨ®ĩĪĢī®ĬĪĠģĤ®ĭĢĥĤĪĮį®ĥĠģĨĤĪ®İĤĪĪĤģġı®IJħĤĪĤģġĨĨğ®ijĢİĨĪĴĵĶ ķĵĶ ĸĵĵĶķĹĶ ĺĨĤĪį Ļ ĸĵ ĸĻ ļĻ ćāĉĄĈĆ®þĄĆĝÿĆďĈĉĊĄ®ąĈĆĆĈĉĂĐ Ľľ®ĐĿŀŁ®þŁłŃńŅņ®ąŀŁŁŀŇņň®ʼn®®Ŋŋ®ĐĿŀŁ®ćŌŇĿŀŁ®þłōĿŁ®ąŀŁŁŀŇņň® ŎŏŐőŒœŒ®Ŕő®ŕŖŖŗŘ®řŚŔőś®ŜŏŝśŚ®®ŔŞ®şŠœ®šŏŚŝŒŢŞ®ŝœśŒŔőţ® ŤŏťŦŚœŠœőŞŔŧœ®ŞŏŝŐşŔŏőŞ®ŦŚŏŧŔŒœŚ®ŨŏŚ®ŞŏŝśŚ®œőœŚţũŪ® šœ®ūœŝŔœŧœ®ŤŝŏŞœ®ŤŏŏŦœŚśşŔŏő®šŔşŠ®ŏŐŚ®ŦśŚşőœŚŞ®ŔŞ® ŤŚŔşŔŤśŝ®şŏ®ŞŐŤŤœŞŞŪ®řŚŔőś®ŜŏŝśŚ®őŏš®ŒŔŞşŚŔūŐşœŞ®ŔşŞ® Ŭŭ®ŦŚŏŒŐŤşŞ®şŏ®ŏŧœŚ®Ůů®ŤŏŐőşŚŔœŞ®śŝŝ®ŏŧœŚ®şŠœ® šŏŚŝŒŪ®řŚŔőś®ŔŞ®śūŝœ®şŏ®ŦŚŏŧŔŒœ®œŰŤœŦşŔŏőśŝ®ŞœŚŧŔŤœ® şŏ®œśŤŠ®ŤŐŞşŏťœŚ®Ŕő®œśŤŠ®ťśŚűœş®śőŒ®ŞŐŦŦŝœťœőş® ŏŐŚ®ŔőőŏŧśşŔŧœŘ®ŚœŝŔśūŝœ®ŦŚŏŒŐŤşŞ®šŔşŠ®şŠœ®ūśŤűŔőţ® ŏŨ®řŚŔőś®śŞ®ś®ŞşŚŏőţŘ®ūśőűśūŝœ®ŦśŚşőœŚŪ®Ųœ®śŚœ® ŤŏťťŔşşœŒ®şŏ®ūŐŔŝŒŔőţ®ŞşŚśşœţŔŤŘ®ťŐşŐśŝŝũ® ūœőœųŤŔśŝ®ŤŏŝŝśūŏŚśşŔŏő®šŔşŠ®ŔőŞşśŝŝœŚŞŘ®ŒœŧœŝŏŦœŚŞŘ® ŒŔŞşŚŔūŐşŏŚŞ®śőŒ®ŏşŠœŚ®ŦśŚşőœŚŞŪ ŴŵŶ®ŷŸŹźŻż®ŽŻžźſƀƁƂźŻŹ ƃƄƅŮŕƆŕƇƈƃƄƅŮŕŗƉůƈƊƋŕŗůƉƈƃƄƅŮŕŗůŕƈƃƄƅŮƆŗŕŮ ƃŜƌ®Ŗůůŕƍ®®ƎŐśŝŔşũ®Əśőśţœťœőş®ŜũŞşœť ƃŜƌ®ŕƐůůŕƍ®®ƄőŧŔŚŏőťœőşśŝ®Əśőśţœťœőş®ŜũŞşœť ƃŜƌŕƐůŮƐƍ®®ƑŚœœőŠŏŐŞœ®ţśŞœŞ®ƄťŔŞŞŔŏőŞ®ŭœŚŔųŤśşŔŏő ƌƒŜƓŜ®ŕƔůůŕƍ®®ƌŤŤŐŦśşŔŏő®ƒœśŝşŠ®śőŒ®ŜśŨœşũ® Əśőśţœťœőş®ŜũŞşœť ŽƕżƖžŻƗŻŵŹſƘŻ®ƙžƕŶƚƁźŹ® ƛ0123405®27®8329¯2°±5®290®²7¯2®³9°´´0±µ3±µ®0±¶317±²0±2°´®³7±53237±¯ ®·¸¹¹®º»®¼½¾¿®ÀÁ»¿Â ®Ã¸¹¹®º»®Ä¾Á¼®ÀÁ»¿Â ®ƜîÅŮƻ½À®ÄÇÁ¾ÈÄ®»Ç®ÉÊ®ËÅÌÆ ͰÎ3²3Ï0®´3²3205®¯Ð°³0®8329®27ÐÑ0±5®0Ò³30±³Ó ®ÔÕ®ÇÁ®ÖÉ·×ÌÅØ®ÕÁ¼ÈƝ®¿È¾Ä½ÇÙ ®ÚÁ¼®ÇÆÈƝÅ»À®ÛÁÈÜ۽ȾÇÄ®ÝÁƝ®ÞƝÈ»ÇÈƝ®È¾ÈƝÞÙ®ÕƝÁ¿ßÛǽÁ¾®»Ç®Æ½ÞÆ ÁÕÈƝ»Ç½¾Þ®ÇÈÅÕÈƝ»ÇßƝÈÄ à3µ9´Ó®10´3°á´0®5â0®27®¯213±µ0±2®ãâ°´32Ó®³7±217´ ®äåÈƝ®Ɯ¹®½¾æÆÁßÄÈ®ÇÈÄÇÄ®ƞÔçè®éêè®ëìè®»¾¿®Å»¾Ù®ÅÁƝÈíÂ Â®î¾æÆÁßÄÈ®ÇÈÄǽ¾Þ®ÞÁÈÄ®¼ÈÀÀ®ïÈÙÁ¾¿®ÛÈƝǽðۻǽÁ¾®ƝÈñß½ƝÈÅȾÇÄ Â®ºîò®ƝÈĽÄÇ»¾Ç ®ֹ¹ó®ôÚ®¿ÁßïÀÈ®½¾ÄÕÈÛǽÁ¾ õö÷øù÷úù®õöüý®þ÷úú÷øöÿĀúāø÷®Ăāøü÷ú®þ÷úú÷øöÿ  04/27/18 012®456278®9¯®°2®±9²5³7´µ¶Ɵ·¸ ¹ º¹ »¹ ¼¹ ½¹ ¾¹ ¿ÀÁÂÃÄƜÅ¿ÆÇÈÉÉƜÊ®ÅÌÆºÍ¹ »Í¹ ¼Í¹ ½Í¹ ¾Í¹ Î͹ Ï͹ Ð͹ Ñ͹ º¹Í¹ º¹¹¹ÒÓÔÕ Ð¹¹ÒÓÔÕ Î¹¹ÒÓÔÕ ½¹¹ÒÓÔÕ »¹¹ÒÓÔÕ Ö×ÌØƝٮιÚÇƝÛÛ®ØÜÙÝÛƝ Þßàáââãäåæãƞçèèé Þßàáââãäåæãäçèèé êƞãáëìäí êîäáëìãí ïðñòóôõö ïñ÷øð®ðúûüø °12®456278®9¯®°2®±9²5³7´µ¶Ɵ·¸ ¹ º¹ »¹ ¼¹ ½¹ ¾¹¿ÀÁÂÃÄƜÅ¿ÆýÀþƜÉ®ÅÒÆ ¾¹ º¹¹ º¾¹ »¹¹ »¾¹ ¼¾¹ ¼¹¹º¹¹¹ÒÓÔÕ Ð¹¹ÒÓÔÕ Î¹¹ÒÓÔÕ ½¹¹ÒÓÔÕ »¹¹ÒÓÔÕ ÑѻӼÑͺºÎ¾¹ÓÎ¾Í¹Ì ²0±7ÿ809ÿ8®9¯®°2®±9²5³7´ĀĀāĂăĄƠąĆ¸® ѽĈÓ¼ÏÍĉ ºÐ¹ÓÏͺ º¾¹Ó¾ÍÑ ÑѹӼÑ͹ ¼¼¹Óº¼Í¹º»ÚÙÉÃĊÊ®ċÀÁƜ º¹¹¹Ó¼Ñͽơº¹Ó¹Í¼ÑČÈÊčÂĊÀÊ®ĎÀď ĐÃÔƜđÁÃÂƜ ÎÚĒ®½Í¼® ēÉÀÈÊĔĊÊÄ®ċÀÁƜ ĕĖė®ęĚěĕ® ĜÊĝÂÃÁÁĊÊÄ®®ċÀÁƜ Ì ĎÃčĞ®¿ĊƜþ ¼¾ÓºÍ¼Ð ¼¾ÓºÍ¼Ð¼¾ÓºÍ¼ÐººÓ¹Í½¼ ğĊÁĊčÀÊ®ğƜÃÁÃÊ ÛÃÔĊÊÃÂƜ ÖÉÃÔƜ ÅÌÚÌÆ ĠġĢģĤ®ƢĦĢĢħ ƢĦĢĢ®ĨĤĩĦĪīģīĩġĪ ĬġĭĮĢĦ®įĩİĦĪħĩġĪħ ıĦĩIJijī ĴĢģħħ ĵģĶķħijĦĦī ĸĤģİĦ ĹĺĵġĻ ƢģļĢĦħ ƢġĪĪĦĶīġĤ ĸĩĤĦ®ĽľĿĦ ĬŀƢŁłŃńƢłŅ®įłĽł ņŇňŇʼnŊŋŌōŎŏŏŐňő®œƣŔŕŖƣ®ŗ®œƣŔŕŖƣ®ŘŘ®řŔ®ŐňʼnŚőŌś ŔŜ®ʼnőŏŏŌ®řŔ®ŗ®œŜś œŔƣŜ®ŗ®ŝŝŞ®ŗ®şƣ®ŘŘ®řŔƣŕŜ®ŗ®şŝŕœ®ŗ®œŕşŠ®ŐňʼnŚőŌś œŠŕŔ®šŢ®řţœŕŜ®ŏŤś şŕŞ®ŘŘ®řŜŕœş®ŐňʼnŚőŌśť®ŦŐŢŚ®ŧŊŎňŌŘŐŌŌŐŇňť®Ũũ®ŪŇŎōőū®ŧőŘŬőŊőū®ŭŏŎŌŌ® ŮŚŐōő®ůŰŰŜƣŨŕŜŠřűűśŲų ŴŏŎʼnš®ůŰŰŜƣŨŕŜƣřűűśŲ ŴŏŎʼnš®®ŨňŇūŐŵőū®ŨŏŶŘŐňŐŶŘ®ŨŏŏŇŋ®ůŰŰŜƣŨŕŜŠřűűśť®ŰŰŜƣŨŕŜƣřűűśŲ® űƤ®ŔŖ®ŇŊ®űƤ®ŔŠ®ŊŎōőū ƤŚŇōŇŷŇŏōŎŐʼn®ŧőʼnŚňŇŏŇŢŋ®ŪŎŤŏő®ţŕŜŘŘŸ®řŜŕŜŜŔ®ŐňʼnŚőŌŸśť® œŜŜŜ®ŘŘ®řşŝŕţ®ŐňʼnŚőŌś ŹźŻżŽ®Źſţ®ƁƂƃƄ®ƅƆƇƈ®ƉƊƋƅƊƌƍƎ ŧŋŬő®œ®ŇŊ®ŧŋŬő®Ş ƏƐƏƑƒƓƔƑƕƐ®Ɨƕƒƕ®ƘƙƒƑƚ® ƛ012®45567869¯°®±²²²³´µ¶Ɵ®1°··®0°µ¸°56¹º5°®»¼½1Ɵ®¾85®¿6ÀÀ®¾¿±Á¼Á ¿°6Àº589®¹Ã·°569¯°2®ÄƜÅÁÆ Ɯ±¼ ƜƜÁƜ ÇÁÈÉ È²Á¼ ±²Á² ±ÇÁ» »Ç² Ɯ»Á» ÇÁ²± ƜÊÁÇ ÇÁÉÉ ±ËÁË »Ç¼ Ɯ»Á¼ ÇÁ²Ê ƜÇÁÉ ÇÁÉÊ ±ÊÁ² Ɯ²² Ɯ»ÁÉ ÇÁ±Ç ƜÇÁÊ ÇÁËË ±ÊÁƜ »Ë¼ Ɯ±ÁÈ ÊÁËÉ ƜÊÁÈ ÇÁ»È ±ÉÁÊ »Ê² Ɯ±ÁË ÊÁÊÈ ƜÊÁÈ ÇÁÈ» ±ËÁ± »Ê¼ Ɯ±ÁÊ ÊÁÇË ƜÊÁ¼ ÇÁ¼± ±ËÁÈ ÌÍ102®45567869¯°®6¹®Ê²²³´µ¶Ɵ®¾µÎ8°9¹®0°µ¸°56¹º5°®»²½1Ɵ®³897® ƛ¸°°7®±µ´ÀÁ ƏƐƏƑƒƓƔƑƕƐ®Ɨƕƒƕ®ƘÏÐƑƒƚ ¿6Ñ8µºµ®ÒÃÓ°5ÔÒ¿¾Õ®Ö³¸× ¿6Ñ8µºµ®ÒÃÓ°5®ØÃ·¹6Â°ÔØ¿ÒÒ®ÖØ× ¿6Ñ8µºµ®ÒÃÓ°5®1º55°9¹Ô4¿ÒÒ®Ö¾× Í¸°9®185¯º8¹®ØÃ·¹6Â°ÔØÍ1®ÖØ× ƛƝÃ5¹®185¯º8¹®1º55°9¹Ô4ƛ1®Ö¾× »²Ç »ÇÁÈ ËÁ±² Ɯ¼ÁË ËÁɱ »±» »ÇÁ¼ ËÁ»± Ɯ¼ÁÊ ËÁÉÊ »±É »ÇÁÇ ËÁ»È ƜÉÁ» ËÁʲ »Ɯ¼ Ɯ²ÁÇ ËÁɲ ƜËÁÉ ÊÁ±² »»² Ɯ²Á± ËÁƜ² ƜÉÁÊ ËÁÊ» »»Ɯ Ɯ²Á» ËÁƜÊ ƜËÁ² ËÁÊÇ »²¼ »ÇÁ± ËÁ²È Ɯ¼ÁË ËÁÈÉ Ɯ±² ƜƜÁ± ÇÁƜË È²Á» ÇÁÇÈ ±ÊÁÇ Ɯ²¼ Ɯ»ÁÇ ÇÁ»Ê ȲÁ² ÇÁʼ ±ÊÁÉ Ò°6Ù®ÒÃÓ°5®³6¹¹ÀÔÒ¿¾Õ®Ö³¸×Æ ÒÃÓ°5®Íº¹¸º¹®0÷°569¯°ÔÒ¿¾Õ®Ö³× ¿6Ñ8µºµ®ÒÃÓ°5®ØÃ·¹6Â°ÔØ¿ÒÒ®ÖØ× ¿6Ñ8µºµ®ÒÃÓ°5®1º55°9¹Ô4¿ÒÒ®Ö¾× Í¸°9®185¯º8¹®ØÃ·¹6Â°ÔØÍ1®ÖØ× ƛƝÃ5¹®185¯º8¹®1º55°9¹Ô4ƛ1®Ö¾× ¿Ã7º·°®ÚÛ¯8°9¯Ü®®®® µ®ÖÅ× ²®Ý®Þ¼ »Ɯ± Ɯ²ÁË ËÁ¼Ɯ ƜËÁÈ ÊÁ²Ɯ »»Ë Ɯ²Á¼ ËÁÈÉ ƜËÁ» ËÁǼ ßßàá®ãäåàáæ ƞ®çèéêëìàá ƞ®çèåêëìàá çèçíëìàá îïðñïòóîôòï®òóîö÷øù úûáüãúýþÿĀāĂ®ûăĄƠāąÿĀĆ®áĄĂĂ®üĄþăĄƠāąćƠĄæ üĄþăĄƠāąćƠĄ®áýĄĈĉÿĄĀą®ýĊ®ċơČč üĄþăĄƠāąćƠĄ®áýĄĈĉÿĄĀą®ýĊ®Ďûá® üĄþăĄƠāąćƠĄ®áýĄĈĉÿĄĀą®ýĊ®ďĐá ðóđöðôð®òóîö÷øù ûăĄƠāąÿýĀāĂ®üĄþăĄƠāąćƠĄ ơāĒÿþćþ®ĐēĔąĄþ®ĎýĂąāĆĄ ƞßçĕĖėíàá ĘçççĎ®ęá®ãďĚáæ ĘçççĎ®ęá®ãěĜæ ơāĒ®ĐĄƠÿĄĔ®ĝćĔĄ®ĞāąÿĀĆ ĘíČ®ãċýğĄƠ®Ġåėíġæ Ęç®ēĄāƠ®ċƠýĢćĉą®ġýƠģþāĀĔĤÿă®ġāƠƠāĀąē åí®ēĄāƠ®ĜÿĀĄāƠ®ċýğĄƠ®ġāƠƠāĀąē ãċĂĄāĔĄ®ƠĄĊĄƠ®ąý®ăƠýĢćĉą®ğāƠƠāĀąē®ĊýƠ®ĢĄąāÿĂĔæ ĥóòòó÷îƢ ñóĦħóøö÷ø®ĦĨ÷ĩöøôòóîöĨ÷ ơýĢćĂĄĔ®ăĄƠ®ĪýĒī®éç®ăÿĄĉĄĔ ơýĢćĂĄĔ®ăĄƠ®ßçĬ®ĉýĀąāÿĀĄƠī®ėßç®ăÿĄĉĄĔ åçČ®ãċýğĄƠ®ĭåêçġæ ãęû®úûü®ĉýĀĀĄĉą®ĝćĔĄ®ÿĀ®áýþĪÿĀĄƠ®ĮýĒ®ğÿąĤ®ąğý®ýƠ®þýƠĄ®ĔąƠÿĀĆĔ®ÿĀ® ăāƠāĂĂĄĂ®ĉýĀĀĄĉąÿýĀæ áČěüďûúī®ĞĚČę®ĐČĝĚüį®Čúę®ďúĐüČĜĜČüďûú®ďúĐüĞěáüďûúĐ®ĮĚĝûĞĚ®ěĐďúİ®üıĚ®ċĞûęěáüè IJ®åçĘij®üƠÿĀā®ĐýĂāƠ®ĜÿþÿąĄĢè®ČĂĂ®ƠÿĆĤąĔ®ƠĄĔĄƠĴĄĢè®ĐăĄĉÿĊÿĉāąÿýĀĔ®ÿĀĉĂćĢĄĢ®ÿĀ®ąĤÿĔ®ĢāąāĔĤĄĄą®āƠĄ®ĔćĪĵĄĉą®ąý®ĉĤāĀĆĄ®ğÿąĤýćą®ĀýąÿĉĄè® ĎĄƠĔÿýĀ®ĀćþĪĄƠī®üĐơķĚúķåçĘĸķĹ® ğğğèąƠÿĀāĔýĂāƠèĉýþ 04/27/18 SolarEdge Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US INVERTERSwww.solaredge.usUSA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA Optimized installation with HD-Wave technology Specifically designed to work with power optmizers Record-breaking efficiency Integrated Arc Fault protecton and Rapid Shutdown for NEC 2014 and 2017, per artcle 690.11 and 690.12 Extremely small High reliability without any electrolytc capacitors Built-in module-level monitoring Outdoor and indoor installaton Optonal: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) 12-25 04/27/18 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2017. V.01. Subject to change without notice. Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US OUTPUT Rated AC Power Output 3000 3800 5000 6000 7600 VA Max. AC Power Output 3000 3800 5000 6000 7600 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) - - 3 - - Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 Vac AC Frequency (Nominal) 59.3 - 60 - 60.5(1) Hz Maximum Contnuous Output Current 208V - - 24 - - A Maximum Contnuous Output Current 240V 12.5 16 21 25 32 A GFDI Threshold 1 A Utlity Monitoring, Islanding Protecton, Country Configurable Thresholds Yes INPUT Maximum DC Power 4650 5900 7750 9300 11800 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - - 15.5 - - Adc Maximum Input Current 240V 8.5 10.5 13.5 16.5 20 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protecton Yes Ground-Fault Isolaton Detecton 600k Sensitvity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nightme Power Consumpton < 2.5 W ADDITIONAL FEATURES Supported Communicaton Interfaces RS485, Ethernet, ZigBee (optonal), Cellular (optonal) Revenue Grade Data, ANSI C12.20 Optonal(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatc Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connecton Standards IEEE1547, Rule 21(3), Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 0.75-1” Conduit / 14-6 AWG DC Input Conduit Size / # of Strings / AWG Range 0.75-1” Conduit /1-2 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in / mm Weight with Safety Switch 25.3 / 11.5 lb / kg Noise < 25 dBA Cooling Natural Convecton Operatng Temperature Range -13 to +140 / -25 to +60(4) (-40˚F / -40˚C opton)(5) ˚F / ˚C Protecton Ratng NEMA 3R (Inverter with Safety Switch) (1) For other regional setngs please contact SolarEdge support(2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) Pending certficaton(4) Power de-ratng from 50˚C(5) -40 version P/N: SExxxxH-US000NNU4 04/27/18 POWER OPTIMIZERwww.solaredge.usUSA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA SolarEdge Power Optimizer Module Add-On For North America P300 / P400 / P405 Up to 25% more energy Superior efficiency (99.5%) Mitgates all types of module mismatch losses, from manufacturing tolerance to partal shading Flexible system design for maximum space utlizaton Fast installaton with a single bolt Next generaton maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level 04/27/18 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 09/2014 V.01. Subject to change without notice. (2) It is not allowed to mix P405 with P300/P400/P600/P700 in one string. P300 (for 60-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) INPUT Rated Input DC Power(1) 300 400 405 W Absolute Maximum Input Voltage (Voc at lowest temperature)48 80 125 Vdc MPPT Operatng Range 8 - 48 8 - 80 12.5 - 105 Vdc Maximum Short Circuit Current (Isc) 10 Adc Maximum DC Input Current 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optmizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) Pxxx-2 series 141 x 212 x 40.5 / 5.55 x 8.34 x 1.59 mm / in Pxxx-5 series 128 x 152 x 27.5 / 5 x 5.97 x 1.08 128 x 152 x 35 / 5 x 5.97 x 1.37 128 x 152 x 48 / 5 x 5.97 x 1.89 mm / in Weight (including cables)Pxxx-2 series 950 / 2.1 gr / lb Pxxx-5 series 770 / 1.7 930 / 2.05 930 / 2.05 gr / lb Input Connector MC4 Compatble Output Wire Type / Connector Double Insulated; Amphenol Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ſt Operatng Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protecton Ratng Pxxx-2 series IP65 / NEMA4 Pxxx-5 series IP68 / NEMA6P Relatve Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. SolarEdge Power Optimizer Module Add-On for North America P300 / P400 / P405 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2)SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optmizers)8 10 18 Maximum String Length (Power Optmizers)25 25 50 Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientatons Yes 04/27/18