Loading...
HomeMy WebLinkAboutB18-0247_Documents_1529967936.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Construction B18-0247 Issued: 06/25/2018 TOWN OF VAIL Property Information Address: 1040 VAIL VIEW DR (210301408999) ( 210301408999 ) Unit #: Parcel Number: 210301408999 Legal Description: Contacts Contact Type: Applicant Full Name: Debbie Cary Address: PO Box 810, 825-A Chambers Ave PO Box 810, 825-A Chambers Ave 825- A Chambers Ave Eagle, CO 81631 Phone: 9703282699 Contact Type: Property Owner Full Name: Common Area Address: Phone: None Contractor Contractor Type: Mechanical Company: R & H Mechanical LLC State License #:Phone: 970-328-2699 Project Information Project Name: Snow Lion Boilers 2018 Project Description: Replace Old Boilers with (2) Lochinvar "FTXL850" 850,000 BTU High Efficiency Gas Fired Boiler. Boiler Equipped with CFD Controls and Low Voltage Controls and Low Water Cut Offs Required for Commercial Installations. (1) Condensate "Newtralizer" Axiom NT-15 for Boiler. Each Boiler Vented in 6" CPVC Pipe Through the Existing Flue Pipe and Chase and Terminated at the Roof. New Grundfos Circ Pump for Each Boiler (UPS 40-80/4). New Grundfos Magna 3 65-120F Circ Pump (Existing Magna 3 to Remain). (2) New Lochinvar "Squire" SIT119 Indirect Fired Domestic hot Water Makers. (1) Mixing Valve Symmons 7-900A. (1) New Grundfos UPS Recirc Pump will be Installed on the Existing Domestic Hot Water Recir Line Fees Paid Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$2,496.24 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$2,700.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$675.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Total Paid:$5,876.24 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. FTXL FIRE TUBE CONDENSING BOILER Submital Sheet FTX-Sub-03 Job Name: __________________________________ Location: __________________________________ Engineer: __________________________________ Wholesaler: __________________________________ Contractor: __________________________________ NOTES: Model No. __________________________________ Type Gas: __________________________________ Equipment Tag(s): _____________________________________________ _____________________________________________ FTXL FIRE TUBE COMMERCIAL BOILERS 53-1/2" H F 26-1/4" 2-1/2"22-1/2" A 65-1/2" 2-1/2" G 40" 9-3/4" C A B D E 26-1/4" Air Inlet Electrical Connections Water Outlet Water Inlet Flue Connection Condensate Connection Gas Connection Input Gross NET AHRI Flow HEX Model Min Max Thermal Output Rating Turn (GPM) Water No. MBH MBH Eff. MBH MBH down Min Max Volume FTX400(N,L) 40.0 399.9 98.0% 392 341 10:1 10 105 13 FTX500(N,L) 50.0 500.0 97.7% 489 425 10:1 15 105 12 FTX600(N,L) 85.0 600.0 97.5% 585 509 7:1 15 105 12 FTX725(N,L) 103.5 725.0 97.2% 705 613 7:1 20 150 17 FTX850(N,L) 121.5 850.0 97.0% 825 717 7:1 25 150 16 Ship Water Vent Air Gas Wt. A B C D E F G H Conn. Size Intake Conn. (lbs.) 30-1/2" 27-1/2" 10-1/4" 17" 23-1/4" 46-1/4" 39-1/2" 10-3/4” 2" 4” 4” 1” 435 30-1/2" 27-1/2" 10-1/4” 17" 23-1/4" 46-1/4" 39-1/2” 10-3/4” 2" 4” 4” 1” 460 30-1/2" 27-1/2" 10-1/4” 17" 23-1/4" 46-1/4" 39-1/2” 10-3/4” 2" 4” 4” 1” 470 33” 28-1/2" 10-1/2” 17-1/2" 23-1/2" 48-1/2" 41-1/4” 11" 2-1/2" 6” 4” 1” 510 33" 28-1/2" 10-1/2” 17-1/2" 23-1/2" 48-1/2" 41-1/4" 11" 2-1/2" 6” 4” 1” 535 Dimensions and SpecificationsFTXL Boiler *Informaton subject to change without notce. Dimensions are in inches. Select “N” or “L” for Natural or LP gas. *The Net AHRI Water Ratngs shown are based on a piping and pickup allowancof 1.15. *Lochinvar should be consulted before selectng a boiler for installatons having unusual piping and pickup requirements, such as intermitent system operaton, extensive piping systems, etc. *The ratngs have been determined under the provisions governing forced draſt burners. FOR EASE IN ORDERING BY MODEL NUMBER FTX 850 N M13 F T X L Boi l e r N at u ral G a s This model is: - FTXL Fire Tube boiler - 850,000 Btu/hr - Natural gas - M13 Firing Controls 8 50 ,0 0 0 Bt u /Hr In pu t Fi ri n g Co ntro l FTX850(N,L) 121.5 850.0 97.0% 825 717 7:1 25 150 16 33” 28-1/2” 10-1/2” 17-1/2” 23-1/2” 48-1/2” 41-1/4” 11” 2-1/2” 6” 4” 1” 535 Snow Lion Vail Radar Engineering Dahl Avon R & H Mechanical LLC FTXL 850 X2 Natural B1 - B2 Smart System Features > Smart System Digital Operating Control Multi-Color Graphic LCD Display w/Navigation Dial > Loch-N-Link™ USB Thumb Drive Port for Easy Programming > Cascading Sequencer with Built-in Redundancy Selectable Cascade Type: Lead Lag/Efficiency Optimization Multiple Size Boilers Front-End Loading > 3 Reset Temperatures Inputs w/Independent Outdoor Reset Curves for Each Outdoor Sensor > Four-Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable-Speed Control Domestic Hot Water Boiler Pump Domestic Hot Water Recirculation Pump Control with Sensor > Building Management System Integration 0-10 VDC Input to Control Modulation or Setpoint 0-10 VDC Input from Variable-Speed System Pump 0-10 VDC Modulation Rate Output Signal 0-10 VDC Enable/Disable Signal > Programmable System Efficiency Optimizers Space Heating Night Setback DHW Night Setback Anti-Cycling Ramp Delay Boost Time and Temperature > High-Voltage Terminal Strip 120 VAC/60 Hertz/1 Phase Pump Contacts for 3 Pumps > Low-Voltage Terminal Strip Building Recirculation Pump Start/Stop Building Recirculation Return Temp Sensor Contacts Proving Switch Contacts Flow Switch Contacts Alarm Contacts Runtime Contacts 3 Space Heat Thermostat Contacts Tank Thermostat Contacts System Sensor Contacts Tank Sensor Contacts Cascade Contacts 0-10 VDC BMS Contacts 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Boiler Pump Speed Contacts 0-10 VDC System Pump Speed Contacts ModBus Contacts > Time Clock > Data Logging Ignition Attempts Last 10 Lockouts Space Heat Run Hours Domestic Hot Water Run Hours Standard Features > 97%-98% Thermal Efficiency > Modulating Burner with up to 10:1 Turndown Direct Spark Ignition Low NOx Operation Sealed Combustion Low Gas Pressure Operation > Stainless Steel Fire-Tube Heat Exchanger ASME-Certified, “H” Stamped 160 psi Working Pressure 50 psi Relief Valve Combustion Analyzer Test Port Fully Welded Design > Vertical and Horizontal Direct Vent Direct Vent up to 100 feet PVC, CPVC, Polypropylene or AL29-4C Factory Supplied Sidewall Vent Termination > Smart System Control > Other Features On/Off Switch Adjustable High Limit with Manual Reset Automatic Reset High Limit Manual Reset Low Water Cutoff Flue Temperature Sensor Low Air Pressure Switch Temperature and Pressure Gauge Condensate Trap Zero Service Clearances 10-Year Limited Warranty Low Water Cutoff Custom Maintenance Reminder with Contact Info Password Security Customizable Freeze Protection Parameters Optional Equipment CON·X·US Remote Connectivity ModBus Communication BMS Gateway to BACnet or LonMark SMART SYSTEM PC Software Alarm Bell Motorized Isolation Valve Wireless Outdoor Temperature Sensor Multi-Temperature Loop Control Variable-Speed Boiler Circulator Constant-Speed Boiler Circulator Condensate Neutralization Kit Concentric Vent Kit (FTX400-FTX600) Common Vent Kits High and Low Gas Pressure Switches w/Manual Reset (FTX500-FTX850) 30 psi ASME Relief Valve 75 psi ASME Relief Valve 100 psi ASME Relief Valve 125 psi ASME Relief Valve 150 psi ASME Relief Valve > Firing Controls M9 - Standard Construction M13 - CSD-1/FM/GE Gap (FTX500-FTX850) 11/17—Printed in U.S.A. Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com CON·X·US® REMOTE CONNECT CAPABLE CASCADING SEQUENCER LOCH-N-LINK™ USB DRIVE SETUP 5 INPUTS FROM 399,999 TO 850,000 BTU/HR UP TO 10:1 TURNDOWN RATIO COMMON VENT AND PVC DIRECT-VENTING FLOW RATES FROM 10 TO 150 GPM SMALL 6.2 SQ. FT. FOOTPRINT 4 PUMP CONTROL WIRELESS OUTDOOR SENSOR CAPABLE 4