HomeMy WebLinkAboutB18-0247_Documents_1529967936.pdf75 South Frontage Road
West,
Vail, CO 81657
Office: 970.479.2139
Inspection Line: 970.479.2149
Construction
B18-0247
Issued: 06/25/2018
TOWN OF VAIL
Property Information
Address: 1040 VAIL VIEW DR (210301408999) ( 210301408999 )
Unit #:
Parcel Number: 210301408999
Legal Description:
Contacts
Contact Type: Applicant
Full Name: Debbie Cary
Address:
PO Box 810, 825-A Chambers Ave PO Box 810, 825-A Chambers Ave 825-
A Chambers Ave Eagle, CO 81631 Phone: 9703282699
Contact Type: Property Owner
Full Name: Common Area
Address: Phone: None
Contractor
Contractor Type: Mechanical
Company: R & H Mechanical LLC
State License #:Phone: 970-328-2699
Project Information
Project Name: Snow Lion Boilers 2018
Project Description:
Replace Old Boilers with (2) Lochinvar "FTXL850" 850,000 BTU High Efficiency Gas Fired Boiler. Boiler
Equipped with CFD Controls and Low Voltage Controls and Low Water Cut Offs Required for Commercial
Installations. (1) Condensate "Newtralizer" Axiom NT-15 for Boiler. Each Boiler Vented in 6" CPVC Pipe
Through the Existing Flue Pipe and Chase and Terminated at the Roof. New Grundfos Circ Pump for Each
Boiler (UPS 40-80/4). New Grundfos Magna 3 65-120F Circ Pump (Existing Magna 3 to Remain). (2) New
Lochinvar "Squire" SIT119 Indirect Fired Domestic hot Water Makers. (1) Mixing Valve Symmons 7-900A.
(1) New Grundfos UPS Recirc Pump will be Installed on the Existing Domestic Hot Water Recir Line
Fees Paid
Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$2,496.24
Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$2,700.00
Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$675.00
Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00
Total Paid:$5,876.24
Conditions
CONDITIONS UNDER WHICH PERMITS BECOME VOID:
If construction is not begun within 6 months from the date permit was issued.
If more than 5 months elapses between inspections.
If incorrect information is given on the application at the time the permit was issued.
Christopher Jarecki - Town of Vail Building Official
NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal
law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees.
FTXL FIRE TUBE
CONDENSING BOILER
Submital Sheet FTX-Sub-03
Job Name: __________________________________
Location: __________________________________
Engineer: __________________________________
Wholesaler: __________________________________
Contractor: __________________________________
NOTES:
Model No. __________________________________
Type Gas: __________________________________
Equipment Tag(s):
_____________________________________________
_____________________________________________
FTXL FIRE TUBE COMMERCIAL BOILERS
53-1/2"
H
F
26-1/4" 2-1/2"22-1/2"
A
65-1/2"
2-1/2"
G 40"
9-3/4"
C
A
B
D
E
26-1/4"
Air Inlet Electrical Connections
Water Outlet
Water Inlet
Flue Connection
Condensate Connection
Gas Connection
Input Gross NET AHRI Flow HEX Model Min Max Thermal Output Rating Turn (GPM) Water No. MBH MBH Eff. MBH MBH down Min Max Volume
FTX400(N,L) 40.0 399.9 98.0% 392 341 10:1 10 105 13
FTX500(N,L) 50.0 500.0 97.7% 489 425 10:1 15 105 12
FTX600(N,L) 85.0 600.0 97.5% 585 509 7:1 15 105 12
FTX725(N,L) 103.5 725.0 97.2% 705 613 7:1 20 150 17
FTX850(N,L) 121.5 850.0 97.0% 825 717 7:1 25 150 16
Ship Water Vent Air Gas Wt. A B C D E F G H Conn. Size Intake Conn. (lbs.)
30-1/2" 27-1/2" 10-1/4" 17" 23-1/4" 46-1/4" 39-1/2" 10-3/4” 2" 4” 4” 1” 435
30-1/2" 27-1/2" 10-1/4” 17" 23-1/4" 46-1/4" 39-1/2” 10-3/4” 2" 4” 4” 1” 460
30-1/2" 27-1/2" 10-1/4” 17" 23-1/4" 46-1/4" 39-1/2” 10-3/4” 2" 4” 4” 1” 470
33” 28-1/2" 10-1/2” 17-1/2" 23-1/2" 48-1/2" 41-1/4” 11" 2-1/2" 6” 4” 1” 510
33" 28-1/2" 10-1/2” 17-1/2" 23-1/2" 48-1/2" 41-1/4" 11" 2-1/2" 6” 4” 1” 535
Dimensions and SpecificationsFTXL Boiler
*Informaton subject to change without notce. Dimensions are in inches. Select “N” or “L” for Natural or LP gas. *The Net AHRI Water Ratngs shown are based on a piping and pickup allowancof 1.15. *Lochinvar
should be consulted before selectng a boiler for installatons having unusual piping and pickup requirements, such as intermitent system operaton, extensive piping systems, etc. *The ratngs have been
determined under the provisions governing forced draſt burners.
FOR EASE IN ORDERING
BY MODEL NUMBER
FTX 850 N M13
F
T
X
L
Boi
l
e
r N
at
u
ral G
a
s
This model is:
- FTXL Fire Tube boiler
- 850,000 Btu/hr
- Natural gas
- M13 Firing Controls
8
50
,0
0
0
Bt
u
/Hr
In
pu
t
Fi
ri
n
g Co
ntro
l
FTX850(N,L) 121.5 850.0 97.0% 825 717 7:1 25 150 16 33” 28-1/2” 10-1/2” 17-1/2” 23-1/2” 48-1/2” 41-1/4” 11” 2-1/2” 6” 4” 1” 535
Snow Lion
Vail
Radar Engineering
Dahl Avon
R & H Mechanical LLC
FTXL 850 X2
Natural
B1 - B2
Smart System Features
> Smart System Digital Operating Control
Multi-Color Graphic LCD Display w/Navigation Dial
> Loch-N-Link™ USB Thumb Drive Port for Easy
Programming
> Cascading Sequencer with Built-in Redundancy
Selectable Cascade Type:
Lead Lag/Efficiency Optimization
Multiple Size Boilers
Front-End Loading
> 3 Reset Temperatures Inputs w/Independent
Outdoor Reset Curves for Each
Outdoor Sensor
> Four-Pump Control
System Pump with Parameter for Continuous Operation
Boiler Pump with Variable-Speed Control
Domestic Hot Water Boiler Pump
Domestic Hot Water Recirculation Pump Control
with Sensor
> Building Management System Integration
0-10 VDC Input to Control Modulation or Setpoint
0-10 VDC Input from Variable-Speed System Pump
0-10 VDC Modulation Rate Output Signal
0-10 VDC Enable/Disable Signal
> Programmable System Efficiency Optimizers
Space Heating Night Setback
DHW Night Setback
Anti-Cycling
Ramp Delay
Boost Time and Temperature
> High-Voltage Terminal Strip
120 VAC/60 Hertz/1 Phase
Pump Contacts for 3 Pumps
> Low-Voltage Terminal Strip
Building Recirculation Pump Start/Stop
Building Recirculation Return Temp Sensor
Contacts
Proving Switch Contacts
Flow Switch Contacts
Alarm Contacts
Runtime Contacts
3 Space Heat Thermostat Contacts
Tank Thermostat Contacts
System Sensor Contacts
Tank Sensor Contacts
Cascade Contacts
0-10 VDC BMS Contacts
0-10 VDC Boiler Rate Output Contacts
0-10 VDC Boiler Pump Speed Contacts
0-10 VDC System Pump Speed Contacts
ModBus Contacts
> Time Clock
> Data Logging
Ignition Attempts
Last 10 Lockouts
Space Heat Run Hours
Domestic Hot Water Run Hours
Standard Features
> 97%-98% Thermal Efficiency
> Modulating Burner with up to 10:1 Turndown
Direct Spark Ignition
Low NOx Operation
Sealed Combustion
Low Gas Pressure Operation
> Stainless Steel Fire-Tube Heat Exchanger
ASME-Certified, “H” Stamped
160 psi Working Pressure
50 psi Relief Valve
Combustion Analyzer Test Port
Fully Welded Design
> Vertical and Horizontal Direct Vent
Direct Vent up to 100 feet
PVC, CPVC, Polypropylene or AL29-4C
Factory Supplied Sidewall Vent Termination
> Smart System Control
> Other Features
On/Off Switch
Adjustable High Limit with Manual Reset
Automatic Reset High Limit
Manual Reset Low Water Cutoff
Flue Temperature Sensor
Low Air Pressure Switch
Temperature and Pressure Gauge
Condensate Trap
Zero Service Clearances
10-Year Limited Warranty
Low Water Cutoff
Custom Maintenance Reminder with Contact
Info
Password Security
Customizable Freeze Protection Parameters
Optional Equipment
CON·X·US Remote Connectivity
ModBus Communication
BMS Gateway to BACnet or LonMark
SMART SYSTEM PC Software
Alarm Bell
Motorized Isolation Valve
Wireless Outdoor Temperature Sensor
Multi-Temperature Loop Control
Variable-Speed Boiler Circulator
Constant-Speed Boiler Circulator
Condensate Neutralization Kit
Concentric Vent Kit (FTX400-FTX600)
Common Vent Kits
High and Low Gas Pressure Switches w/Manual Reset
(FTX500-FTX850)
30 psi ASME Relief Valve
75 psi ASME Relief Valve
100 psi ASME Relief Valve
125 psi ASME Relief Valve
150 psi ASME Relief Valve
> Firing Controls
M9 - Standard Construction
M13 - CSD-1/FM/GE Gap (FTX500-FTX850)
11/17—Printed in U.S.A.
Lochinvar, LLC
300 Maddox Simpson Parkway
Lebanon, Tennessee 37090
P: 615.889.8900 / F: 615.547.1000
Lochinvar.com
CON·X·US® REMOTE CONNECT CAPABLE
CASCADING SEQUENCER
LOCH-N-LINK™ USB DRIVE SETUP
5 INPUTS FROM 399,999 TO 850,000 BTU/HR
UP TO 10:1 TURNDOWN RATIO
COMMON VENT AND PVC DIRECT-VENTING
FLOW RATES FROM 10 TO 150 GPM
SMALL 6.2 SQ. FT. FOOTPRINT
4 PUMP CONTROL
WIRELESS OUTDOOR SENSOR CAPABLE
4