Loading...
HomeMy WebLinkAboutStructural Analysis: Entry Stairs Footing5975 S. Quebec St., Suite 250 | Centennial, Colorado 80111 | 303.996.0208 October 18, 2018 West Lupine, LLC Rich Laws RE: Structural Analysis – 3796 Lupine Dr, Vail, Colorado. Dear Rich Laws; At your request, this office performed a structural analysis for the above listed residence. The purpose of the analysis was to review and provide recommendations for the conditions described below. The pertinent information regarding the analysis is as follows: ENTRY STAIRS FOOTING You have reported to this office that the footing for the east side of the A unit entry stairs was poured in the wrong location. You proposed dowelling into the side of the existing footing to allow concrete to be poured adjacent to the existing section, therefore adding to the width of the footing and supporting the wall above. This modification is a commonly accepted practice. This office reviewed photographs of the area with (4) #5 bars dowelled horizontally into the side of the existing footing and (1) #5 bar running along the length of the addition, spliced to an additional dowel at the end. The reinforcing steel for this added section of footing had been properly lapped and tied and had been placed in the forms prior to concrete. Please contact our office if we may be of further assistance. Sincerely, Megan A. Sudik, P.E.