HomeMy WebLinkAboutB18-0417_approved plans_1539713081.pdfFIRE RESISTANCE DESIGNATIONS FW FIRE WALL (IBC SECTION 706) FB FIRE BARRIER (IBC SECTION 707) SE SHAFT ENCLOSURE (IBC SECTION 713) FP FIRE PARTITION (IBC SECTION 708) SB SMOKE BARRIER (IBC SECTION 709) SP SMOKE PARTITION (IBC SECTION 710) CODE SHEET GRAPHICS LEGEND KEY PLAN BEDROOM A3-05 CLOSET A3-04 HALL A3-02 BATH A3-03 HALL 01 A3-01 CLOSET A3-12 BEDROOM A3-13 BEDROOM A3-23 CLOSET A3-22 HALL A3-11 BATH A3-10 BATH 01 A3-20 HALL A3-21 LIVING ROOM A3-24 HALL A3-27 BATH 02 A3-26 CLOSET A3-25 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:36:27 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 2018/09/13 PERMIT SUBMITTAL UNIT 3101 CODE & SCHEDULES A3-01 FOUR SEASONS RESORT AT VAIL Approver 1/4" = 1'-0"1 UNIT 3101 - CODE PLAN UNIT 3101 - DOOR SCHEDULE Mark DOOR ASSEMBLY CODE RATING (MIN.) HARDWA RE SET NO. FRAME COMMENTS PANEL TYPE LEAF QUANTITY OPENING WIDTH HEIGHT THICKNES S MATERIAL FINISH FRAME TYPE MATERIAL HEAD JAMB A3-02 RE:ID 1 2' - 10" 7' - 0" 1 3/4" WD RE: ID 20 PASSAGE W/ TURN BOLT 1 WD 1,3,6,7 A3-03 RE: ID 1 3' - 0" 7' - 0" 1 3/4" WD RE: ID PRIVACY P1 WD 1,3,7 A3-03.A RE:ID 1 2' - 10" 7' - 0" 1 3/4" WD RE: ID PRIVACY 1 WD 1,3,7 A3-04 F 2 3' - 4" 7' - 0" 1 3/4" WD RE: ID PASSAGE 2 WD 1,3,7 A3-10 RE: ID 1 3' - 0" 7' - 0" 1 3/4" WD RE: ID PRIVACY P1 WD 1,3 A3-10.A RE:ID 1 2' - 10" 7' - 0" 1 3/4" WD RE: ID PRIVACY 1 WD 1,3,7 A3-11 RE:ID 1 2' - 10" 7' - 0" 1 3/4" WD RE: ID 20 PASSAGE W/ TURN BOLT 1 WD 1,3,6 A3-12 RE:ID 1 2' - 10" 7' - 0" 1 3/4" WD RE: ID PASSAGE 1 WD 1,3 A3-20 RE: ID 1 3' - 0" 7' - 0" 1 3/4" WD RE: ID PRIVACY 1 WD 1,3 A3-20.A RE:ID 1 2' - 8" 7' - 0" 1 3/4" WD RE: ID PRIVACY 1 WD 1,3 A3-21 RE: ID 1 3' - 0" 7' - 0" 1 3/4" WD RE: ID PRIVACY 1 WD 1,3 A3-22 RE: ID 1 3' - 0" 7' - 0" 1 3/4" WD RE: ID PASSAGE 1 WD 1,3 A3-25 RE: ID 2 4' - 0" 7' - 0" 1 3/4" WD RE: ID PASSAGE 2 WD 1,3 A3-26 RE: ID 1 3' - 0" 7' - 0" 1 3/4" WD RE: ID PRIVACY 1 WD 1,3 A3-A EXISTING 1 3' - 0" 7' - 0" 1 3/4" WD RE: ID 20 ENTRY 1 EXISTING 1,2,3 A3-B EXISTING 1 3' - 0" 7' - 0" 1 3/4" WD RE: ID 20 ENTRY 1 EXISTING 1,3,5 A3-C EXISTING 2 6' - 0" 8' - 0" 1 3/4" AL RE: ID EXISTING S2 EXISTING 1,2,3 A3-D EXISTING 2 6' - 0" 8' - 0" 1 3/4" AL RE: ID EXISTING S2 EXISTING 1,2,3 0' 1' 4' 8' 16' 2' *NOTES - DOOR SCHEDULE DOOR SCHEDULE NOTES 1 ALL DOOR HARDWARE TO MEET FOUR SEASONS STANDARDS 2 EXISTING DOOR TO REMAIN. REFINISH INTERIOR SIDE, RE: ID 3 RE: ID FOR DOOR HARDWARE SPECIFICATIONS 4 POCKET DOOR. PROVIDE ALL REQUIRED POCKET DOOR HARDWARE 5 NEW CORRIDOR DOOR. RE: ID FOR INTERIOR HARDWARE, EXTERIOR HARDWARE TO MATCH EXISTING CONDO COORIDOR DOORS 6 COMMUNICATING DOOR 7 NEW DOOR LOCATED IN EXISTING DOOR LOCATION. REUSE EXISTING FRAME IF FEASIBLE. VERIFY DOOR SIZE UNIT 3101 BEING CONVERTED TO (2) NON-ACCESSIBLE HOTEL ROOMS & (1) NON-ACCESSIBLE SUITE. SEE COVER FOR COMPLETE CONVERSION PLAN. 10/16/18 REF3.7 4 4.4 5 5.4 4.2 A10 A11 A12 A13 A9.9 HALL 01 A3-01 BATH A3-03 HALL A3-02 CLOSET A3-04 BEDROOM A3-05 BATH A3-10 HALL A3-11 CLOSET A3-12 BEDROOM A3-13 A3-03 A3-A A3-02 A3-04 A3-11 A3-12 A3-10 A3-10.A A3-03.A A3-C A3-D A3-B BALCONY BALCONY HALL A3-27 BATH 01 A3-20 CLOSET A3-22 HALL A3-21 BEDROOM A3-23 LIVING ROOM A3-24 BATH 02 A3-26 CLOSET A3-25 A3-20.A A3-20 A3-22 A3-21 A3-25A3-26 A3-05 4 A3-07 7 A3-06 3 A3-07 1 A3-06 8 A3-07 9 A3-05 6 5 68 1 2 3 1 24 5 6 7 2 3 4 10 11 12 5 7 8 A3-06 9 A3-07 13 A3-05 9 10 11 12 10 11 12 14 15 16 A3-07 17 19 20 18 A3-05 15 13 1416 A3-06 15 13 16 14 23 23 23 23 23 C 26 23 26 43 23 23 43 43 C 22 43 26 23 5' - 3 3/16" 5' - 5 3/16"1 E1 1ALIGNALIGNALIGNALIGN ALIGN 3' - 4 1/4" 16' - 5 3/8"5' - 5 1/2"6.02 6.06 6.02 6.02 22.02 22.02 22.02 22.09 3' - 6"2' - 6 5/8" 2' - 2"6 5/8"7' - 0 5/8" 5' - 3 3/4" ALIGN 43 6' - 3 9/16" 2' - 9" 2' - 8 3/8" 3' - 10"3' - 10" 8' - 8"3' - 2"2' - 4" 4' - 5" 15' - 4 5/8"4' - 2 3/8"6' - 0 7/8" 11.01 6.02 6.03 6.04 6.03 6.04 6.03 6.04 6.03 9.11 9.11 EQEQ 5.03 8.01 8.04 8.04 22.02 3.7 4 4.4 5 5.44.2 A10 A11 A12 A13 A9.9 2.17 2.13 2.12 2.12 2.16 2.14 2.14 2.28 2.14 KEY PLAN DEMO OBJECT EXISTING WALL DEMO PLAN LEGEND AREA NOT IN CONTRACT PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:38 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 2018/09/13 PERMIT SUBMITTAL UNIT 3101 DEMO & FLOOR PLANS A3-02 FOUR SEASONS RESORT AT VAIL Approver 1/4" = 1'-0" 2 UNIT 3101 - FLOOR PLAN 1/4" = 1'-0"1 UNIT 3101 - DEMOLITION PLAN *NOTES - DEMOLITION PLAN DEMOLITION PLAN NOTES 1 EXISTING INFORMATION SHOWN ON THE DRAWINGS IS BASED ON LIMITED FIELD OBSERVATIONS AND/OR INFORMATION PROVIDED BY THE OWNER. OZ ARCHITECTURE IS NOT RESPONSIBLE FOR THE ACCURACY OF INFORMATION OR THE ADEQUACY, SAFETY, AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. THE GC SHALL THOROUGHLY EXAMINE THE PREMISES AND SHALL BASE HIS BID ON THE EXISTING CONDITIONS NOT WITHSTANDING ANY INFORMATION SHOWN, OR NOT SHOWN, ON THE CONTRACT DOCUMENTS. SHOULD ANY DISCREPANCIES BE FOUND, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 2 THE GC SHALL MAINTAIN THE INTEGRITY OF THE EXISTING STRUCTURE AND FIREPROOFING U.N.O. 3 IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING CONSTRUCTION, NOTIFY THE OWNER AND ARCHITECT IMMEDIATELY AND AWAIT FURTHER INSTRUCTIONS. 4 WORK TO BE REMOVED IS ILLUSTRATED IN DASHED LINE-WORK. EXISTING CONSTRUCTION TO REMAIN IS ILLUSTRATED IN LIGHT LINE-WORK. ALL ITEMS FOR REMOVAL MAY NOT BE SPECIFICALLY NOTED. REMOVE ITEMS AS NECESSARY FOR THE COMPLETION OF THE WORK. 5 SEE REFLECTED CEILING PLANS FOR CEILING DEMOLITION WORK. 6 SEE ENGINEERING DRAWINGS FOR THE REMOVAL OF SPECIFIC STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE ALARM SYSTEMS. 7 WHERE THE TERM "REMOVE" OR “DEMOLISH” IS USED, THE GC SHALL REMOVE ITEM FROM THE SITE AND LEGALLY DISPOSE OF. 8 WHERE THE TERM "SALVAGE" IS USED, THE GC SHALL REUSE THE ITEM ON THIS PROJECT OR RETURN TO THE OWNER. 9 WHERE THE TERM "REMOVE AND REINSTALL" IS USED, THE GC IS TO DETACH ITEM FROM EXISTING CONSTRUCTION, PREPARE AND CLEAN ITEM FOR REUSE, AND REINSTALL WHERE INDICATED. 10 WHERE THE TERM "EXISTING TO REMAIN" IS USED, THE EXISTING ITEMS ARE NOT TO BE REMOVED. PROTECT FROM DAMAGE AS REQUIRED. THE GC IS TO REPLACE OR REPAIR ITEMS DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. 11 SALVAGE MECHANICAL EQUIPMENT, PLUMBING FIXTURES, DOORS AND FRAMES, CABINETS, AND LIGHT FIXTURES FOR REINSTALLATION. STORE SALVAGEABLE MATERIALS IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER MATERIAL AND DEBRIS SHALL BE DISPOSED OF BY THE GC. 12 WHERE MECHANICAL, ELECTRICAL, AND PLUMBING DEVICES ARE REMOVED, ABANDONED PIPING AND/OR CONDUITS SHALL BE CAPPED BELOW THE FLOOR, INSIDE THE PARTITION, OR ABOVE THE CEILING AND AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. UNUSED WIRING IS TO BE REMOVED BACK TO PANEL BOXES. PATCH AND REPAIR FINISHES AS REQUIRED TO MATCH SURROUNDING FINISHES. BLANK COVER PLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE U.N.O. 13 EXISTING CONCRETE SLAB DAMAGED DURING CONSTRUCTION SHALL BE PATCHED AND REPAIRED TO A CONDITION SUITABLE FOR NEW FINISHES. 14 PREPARE EXISTING WALLS FOR NEW FINISHES. REMOVE NAILS, PINS, TAPE, POSTERS, ETC.; FILL ALL HOLES; AND PREPARE SURFACES FOR PAINT OR WALLCOVERING. 15 REMOVE BASE IN AREAS WHERE FLOORING IS BEING REMOVED U.N.O. 16 PATCH AND REPAIR FLOOR AND PARTITION FINISHES WHERE INTERSECTING PARTITIONS HAVE BEEN REMOVED. MATCH ADJACENT SURFACE FOR FINISH, COLOR, AND TEXTURE. 17 COORDINATE UTILITY SHUT-DOWNS WITH BUILDING OWNER. 18 FOLLOW RECYCLING PROCEDURES FOR ITEMS TO BE REMOVED AS REQUIRED FOR LEED CERTIFICATION AND/OR BY THE AUTHORITY HAVING JURISDICTION. 19 REMOVE ALL EXISTING APPLIANCES 20 REMOVE ALL EXISTING LIGHTING FIXTURES 21 REMOVE ALL EXISTING PLUMBING FIXTURES 22 REMOVE ALL EXISTING MILLWORK AND TRIM 23 REMOVE ALL EXISTING INTERIOR DOORS, REUSE EXISTING FRAMES WHERE POSSIBLE. 24 REMOVE ALL EXISTING FLOOR FINISHES PROJECT FLAGNOTES NO. FLAGNOTE 2.12 DEMO (E) WALL 2.13 DEMO (E) SHELVING 2.14 SELECTIVE DEMOLITION OF (E) WALL TO CONFIRM ACOUSTIC AND FIRE RATING CONDITION AS REQUIRED 2.16 DEMO (E) FIREPLACE 2.17 DEMO (E) WINDOW AND PORTION OF EXTERIOR WALL REQUIRED FOR NEW WINDOWS. 2.28 SALVAGE (E) DOOR FOR REUSE 5.03 NEW WALL TO BE CENTERED ON (E) WINDOW LOCATION 6.02 NEW MILLWORK, RE:ID 6.03 PROVIDE BLOCKING FOR WALL MOUNTED TV, COORD WITH INTERIORS 6.04 PROVIDE BLOCKING FOR HEADBOARD. COORD WITH INTERIORS 6.06 NEW CLOSET MILLWORK, RE: ID 8.01 NEW DOOR IN EXISTING DOOR LOCATION 8.04 NEW WINDOWS. DRB APPROVED 8/28/2018 #DRB18-0423 9.11 SHOWER NICHE IN (E) WALL VERIFY WALL HAS DEPTH 11.01 NEW FIREPLACE AND SURROUND, RE: ID & MEP 22.02 SHOWER DRAIN LOCATION TBD. BASED ON SLAB XRAY. COORD WITH ARCH *UNIT PLAN NOTES UNIT PLAN NOTES 1 UNIT PLANS MAY BE MIRRORED AND/OR ROTATED RELATIVE TO THE FLOOR PLAN. REFER TO OVERALL FLOOR PLANS FOR LOCATION AND ORIENTATION OF UNITS. 2 SEE OVERALL FLOOR PLANS FOR DEMISING PARTITIONS, UNIT/CORRIDOR PARTITIONS, UNIT ENTRY DOORS, BALCONIES AND EXTERIOR DOORS AND WINDOWS. 3 DIMENSIONS ARE TO FACE OF STUD OR COLUMN CENTERLINE UON. 4 DIMENSIONS DESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED. 5 FURNITURE IS SHOWN FOR LAYOUT PURPOSES ONLY AND IS NIC. 6 “TYPE A” AND “TYPE B” ACCESSIBLE UNITS ARE TO MEET IBC CHAPTER 11 AND ICC A117.1 CHAPTER 10. 7 DEVICES SHALL BE MOUNTED BETWEEN 18" - 48" AFF. DEVICES INCLUDE OUTLETS, THERMOSTATS, SWITCHES, CONTROLS, AND OTHER DEVICES. 8 PROVIDE GRAB BAR REINFORCEMENT AT “TYPE A” AND “TYPE B” ACCESSIBLE BATHROOMS. SEE SHEET G-401. 9 SEE SHEET G-503 FOR PARTITION TYPES. 10 SEE SHEET A-600 FOR DOOR SCHEDULE. 11 SEE INTERIORS SHEETS FOR KITCHEN LAYOUTS 12 SEE INTERIORS FOR BATHROOM LAYOUTS 13 SEE INTERIORS FOR INTERIOR DETAILS AND FLOOR TRANSITIONS. 14 SEE SHEET G-401 FOR TYPICAL MOUNTING HEIGHTS. 0' 1' 4' 8' 16' 2' 10/16/18 3.7 4 4.4 5 5.44.2 A10 A11 A12 A13 A9.9 8'-0" 8'-8" 8'-0"8'-0" 9'-2" 8'-0" 8'-0" 8'-8" 8'-0" 8'-0" 8'-0" 9'-2" 9'-2" 8'-0"8'-0" 8'-0" 9'-2" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-6" 8'-6" 8'-6" 8'-6" 8'-6" 8'-6" 8'-6" 8'-6" 8'-0" 26.02 26.02 26.02 26.02 26.02 26.02 26.02 26.02 26.02 9'-2" 9'-2"2' - 3 1/2"2' - 4 1/2" 2' - 4"2' - 3 1/2"3' - 0 1/2"3' - 4" 3' - 3 1/2"4' - 6" BEDROOM A3-05 3P-01 CLOSET A3-04 3P-01 HALL A3-02 3P-01 BATH A3-03 3P-01 BEDROOM A3-13 3P-01 HALL A3-11 3P-01HALL A3-11 3P-01 CLOSET A3-12 3P-01 HALL 01 A3-01 3P-01 BATH A3-10 3P-01 BEDROOM A3-23 3P-01 CLOSET A3-22 3P-01 HALL A3-21 3P-01 BATH 01 A3-20 3P-01 HALL A3-27 3P-01 LIVING ROOM A3-24 3P-01 BATH 02 A3-26 3P-01 CLOSET A3-25 3P-01 KEY PLAN CEILING PLAN LEGEND GYP. BOARD NOT IN SCOPE PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:44 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 2018/09/13 PERMIT SUBMITTAL UNIT 3101 RCP A3-03 FOUR SEASONS RESORT AT VAIL Approver 1/4" = 1'-0"1 UNIT 3101 - REFLECTED CEILING PLAN *UNIT RCP NOTES UNIT RCP NOTES 1 REFLECTED CEILING PLANS INDICATE CEILING HEIGHTS OF LIGHT FIXTURES, DIFFUSERS, DEVICES, AND SIMILAR ITEMS. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING ELECTRICAL, HVAC, SPRINKLER AND LIFE SAFETY. IN THE EVENT OF A DISCREPANCY BETWEEN THE ARCHITECT'S REFLECTED CEILING PLAN AND THE ENGINEERS' PLANS, SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 2 COORDINATE ALL TRADES INVOLVED IN THE CEILING WORK TO ENSURE CLEARANCE FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS, ETC. NECESSARY TO MAINTAIN THE CEILING HEIGHTS INDICATED. 3 DIMENSIONS ARE TO FINISH U.N.O. 4 COORDINATE LOCATION OF FIRE SPRINKLER HEADS WITH ARCHITECT. 5 LIGHT FIXTURES, SPRINKLER HEADS, AND OTHER CEILING DEVICES SHALL BE EQUALLY SPACED AND ALIGNED WITH ADJACENT ELEMENTS AND CENTERED ON CEILING TILE, U.N.O. 6 PROVIDE UL-CLASSIFIED LIGHT FIXTURES OR ENCLOSURES IN RATED FLOOR/CEILING ASSEMBLIES IN ACCORDANCE WITH IBC CHAPTER 7. 7 VERIFY LOCATION OF ALL ACCESS PANELS REQUIRED BY PLUMBING, MECHANICAL, OR ELECTRICAL SYSTEMS AND COORDINATE LOCATION WITH DESIGN TEAM 8 PAINTED CEILING TYP. RE: INTERIORS FOR SPECIFICATION 9 RE: INTERIORS FINISH FOR CEILING MATRIX FINISH 10 G.C. TO VERIFY EXTENTS ON PLENUM SPACE AND COORDINATE WITH LIGHTING DESIGNER TO VERIFY THAT ALL FIXTURES SPECIFIED TO BE INSTALLED IN THE PLENUM SPACES ARE RATED. PROJECT FLAGNOTES NO. FLAGNOTE 26.02 NEW LIGHT POCKET RE: LIGHTING 0' 1' 4' 8' 16' 2' 10/16/18 COFFEE BAR BEDROOM (A3-05) BEDROOM (A3-13) TERRACE TERRACE COFFEE BAR LIVING ROOM (A3-24) BEDROOM (A3-23) BATH 02 (A3-26) BATH 01 (A3-20) CLOSET (A3-22) CLOSET (A3-25) BATH (A3-10) CLOSET (A3-12) CLOSET (A3-04) BATH (A3-03) SHWR SHWR SHWR SHWR OVAL COCKTAIL TABLE (MATTALIANO - "ETTORE," 50-1/2"Wx 23"D x 16"H) SOFA (88"L x 36"D) LOUNGE CHAIR (31"L x 30"D) SIDE TABLE (24"Ø) 60" LINEAR FIREPLACE (+/- 20-1/8"D BUMP- OUT, w/ 12"x24" DUNE STONE & SLAB HEARTH) WET BAR (54"W x 18"D DRWRS w/ FRIDGE DRWR & BAR SINK, 13"D UPPER CAB, & 2" THICK FLOATING WOOD SHELF ABOVE) AREA RUG (9FT x 12FT) OVAL DINING TABLE (42"L x 24"W) TV WALL (SETBACK FROM F/P WALL, w/ 65" TV) BUILT-IN SEATING (69-1/4"L x 48-3/4"W (OVERALL), SEAT: 19"H, BACK: 24"T, w/ 42"L x 24"W OVAL TABLE & 18"D BENCH) WALL SCONCE (VISUAL COMFORT - "VENICE SCONCE", 12.5"W x 12.5"T x 4"D, BACKPLATE: 8.75" SQ.) (2) FLOATING NIGHTSTANDS & TABLE LAMPS (36"W x 20"D x 16"T) KING BED (w/ UPHOLSTERED HEADBOARD) DRAPERY PANELS (w/ SHADE POCKETS) DINING CHAIR DRAPERY (w/ SHADE POCKETS) (2) FLOATING NIGHTSTANDS & TABLE LAMPS (36"W x 20"D x 16"T) KING BED (w/ UPHOLSTERED HEADBOARD) LOUNGE CHAIR FLOOR LAMP (16"Ø SHADE) DRAPERY PANELS (2) FLOATING NIGHTSTANDS & TABLE LAMPS (36"W x 20"D x 16"T) KING BED (w/ UPHOLSTERED HEADBOARD) RECESSED NICHES (SLAB SILL, w/ FIELD TILE SIDES/ TOP/BACK) EXIST. THRESHOLD EXIST. THRESHOLD 3.7 4 4.4 5 5.44.2 A10 A11 A12 A13 A9.9 A12.2 65 1/2" 65 1/2"1 1 DRESSER (66"W x 18"D x 32"T) DINING TABLE & CHAIRS (30"Ø x 30"T) DRAPERY PANELS WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI-RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) DINING TABLE & CHAIRS (30"Ø x 30"T) LOUNGE CHAIR FLOOR LAMP (16"Ø SHADE) DRESSER (66"W x18"D x 32"T) LOUNGE CHAIR FLOOR LAMP DRESSER (66"W x 18"D x 32"T) WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS,SEMI-RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI- RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) FLOOR LAMP (20''Ø SHADE) TABLE LAMP ART LIGHT 3-PLU-07 (TUB) 3-PLU-02 (SINKS) 3-PLU-01 3-PLU-08 (TUB FILLER) 3-PLU-03 (FAUCETS) 3-PLU-01 3-PLU-02 (SINKS) 3-PLU-08 (TUB FILLER) 3-PLU-15 (TUB) 3-PLU-03 (FAUCETS) 3-PLU-01 3-PLU-02 (SINKS) 3-PLU-03 (FAUCETS) 3-PLU-06 (TUB FILLER) 3-PLU-05 (TUB) 3-PLU-04 3-PLU-04 3-PLU-04 3-PLU-11 3-PLU-09 (SINK) 3-PLU-01 3-PLU-14 3-PLU-13 3-AP-023-AP-01 3-AP-01 3-AP-01 3-PLU-16 3-PLU-10 (FAUCET) PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 ARCHITECTUR ® Sara Shalls 1529 Easy Rider Ln#101 Boulder, CO 80304 Ph: 303.595.5235 9/5/2018 9:27:03 PM 1/4" = 1'-0"FOUR SEASONS - VAILSUITE 3101Project Number PD SS 09/05/2018 100% CONSTRUCTION DOCUMENTS UNIT 3101 DEMO & CONSTRUCTION PLANS A3-04 FOUR SEASONS - VAIL SS 1/4" = 1'-0"2 UNIT 3101 - CONSTRUCTION PLAN 10/16/18 A3-09 3 A3-07 1 A3-06 12 9 10 11 A3-06 14 13 16 15 A3-08 14 A3-09 11 12 9 10 24 3 A3-07 8 5 6 7 A3-09 14 15 16 13 A3-07 15 16 13 14 A3-07 11 9 12 10 24 1 A3-08 11 10 9 12 A3-08 7 5 8 6 A3-08 3 4 1 2 A3-08 13 A3-09 7 8 5 6 A3-06 7 8 5 6 A3-06 2 3 4 1 A3-09 17 COFFEE BAR TERRACE TERRACE COFFEE BAR BATH 02 (A3-26) BATH 01 (A3-20) CLOSET (A3-22) CLOSET (A3-25) BATH (A3-10) CLOSET (A3-12) CLOSET (A3-04) BATH (A3-03) SHWR SHWR SHWR SHWR LIVING ROOM (A3-24) BEDROOM (A3-23) BEDROOM (A3-13) BEDROOM (A3-05) SLAB DECK & APRON (3cm) SLAB DECK & APRON (3cm) RECESSED NICHES (SLAB SILL, w/ FIELD TILE SIDES/TOP/BACK) RECESSED NICHES (SLAB SILL, w/ FIELD TILE SIDES/ TOP/BACK) SLAB HEARTH WALL COVERING FIREPLACE WALL TILE (12X24, HORIZ. DUNE STONE, STRAIGHT SET) ANTIQUE MIRROR RECESSED NICHES (SLAB SILL, w/ FIELD TILE SIDES/ TOP/BACK) RECESSED NICHES (SLAB SILL, w/ FIELD TILE SIDES/ TOP/BACK) 3-CPT-01 3-CPT-01 3-CPT-01 3-WF-01 EXIST. THRESHOLD EXIST. THRESHOLD 3-WF-01 3-WF-01 3.7 4 4.4 5 5.44.2 A10 A11 A12 A13 A9.9 A12.2 3-T-04 3-T-04 3-T-04 3-T-04 3-CPT-01 3-T-04 3-T-04 3-WF-01 3-WF-01 3-WF-01 3-WF-01 3-T-04 3-T-04 3-WF-01 3-WF-01 EXIST. CONCRETE EXIST. CONCRETE PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 ARCHITECTUR ® Sara Shalls 1529 Easy Rider Ln#101 Boulder, CO 80304 Ph: 303.595.5235 9/5/2018 9:27:09 PM 1/4" = 1'-0"FOUR SEASONS - VAILSUITE 3101Project Number PD SS 09/05/2018 100% CONSTRUCTION DOCUMENTS UNIT 3101 RCP & FINISH PLAN A3-05 FOUR SEASONS - VAIL SS 1/4" = 1'-0"2 UNIT 3101 - FINISH PLAN 10/16/18 84" 4 7/8"TOILET ROOM 48"W 12" 72"L BATHTUB 8"96" 20.181"3-T-05 (WALL TILE) 3-PLU-07 (TUB) 3-ST-05 (DECK/APRON, 3cm)3-PLU-01 3-PLU-08 (TUB FILLER) 3-BA-04 166 7/8" 8"96" (FROSTED GLASS) 32"W W.C. DOOR 13" 39" 31 1/2"W TUB 3 cm APRON 20.181"3 cm19"T TUB 32.681" 10.319" 39 7/8"W SHOWER FROSTED GLASS DOOR (TO TOILET ROOM) 3-T-05 (WALL TILE) 3-PLU-07 (TUB) 3-ST-05 (DECK/APRON, 3cm) 3-PLU-04 3-WD-03 3-WD-01 3-HW-0396" 8"84" (CLEAR) 28"GLS PANEL (CLEAR GLASS) 28"SHWR DOOR 4" 24"D VANITY 6" 28" WALL56"W SHOWER CLEAR GLASS SHWR. SURROUND & DOOR ROUND MAGNIFYING MIRROR 84"T CLEAR GLASS SHWR. DOOR/SURROUND 12"3-T-05 (WALL TILE) 3-ST-03 (VANITY TOP) 3-PLU-03 (FAUCETS) 3-PLU-02 (SINKS) 3 cm 3 cmSHOWER 36"W 4 7/8" 88" 38" 4"80"L VANITY/MIRROR 4" 3/4" 13 1/4" 18" 16" 18" 13 1/4" 3/4" 31 1/2"W TUB8" 96" 19"T TUB20.181"5 1/2" 38 1/2" 38 1/2" 5 1/2" 32.681" 5.319" PENDANT LIGHTS (LIUKU BALL GLASS SHADE PENDANT LIGHT, 3ct) LED BACK-LIT MIRROR (93"W x 42"T) ROUND MAGNIFYING MIRROR DOUBLE VANITY (w/ 4" COUNTER, METAL FRAME & WOOD DRWRS/SHLF) RECESSED NICHE (14"T, w/ SLAB SILL & FIELD TILE SIDES/ TOP/BACK) 3-PLU-07 (TUB) 3-PLU-08 (TUB FILLER) 3-ST-05 (DECK/APRON, 3cm) 3-T-05 (WALL TILE) 3-PLU-02 (SINKS) 3-PLU-03 (FAUCETS) 3-ST-03 (VANITY TOP) 3-PLU-04 56"4" (CLEAR GLASS) 28"W SHWR DOOR 28"W CLEAR GLS96"12"84"T CLEAR SHWR. GLASS CLEAR GLASS SHWR. SURROUND & DOOR 1/2" 39 7/8"1/2" GLASS 39 3/8"96"3-T-05 (WALL TILE)48"40"3-PLU-04 60"W SHOWER/NICHE96"RECESSED NICHE (14"T x 4"D, w/ SLAB BOTTOM, FIELD TILE SIDES/BACK/TOP) 3-T-05 (WALL TILE) 36" 4 7/8" 36"W NICHE 3 3/8"1/2" GLS 1"96" CLEAR GLASS SHWR. SURROUND & DOOR RECESSED NICHE (14"T, w/ SLAB SILL & FIELD TILE SIDES/ TOP/BACK)34"14"T NICHE 48" 3-T-05 (WALL TILE) 84"8"96" 60"T.O. COUNTER: 36" 18" 24"4" 3/4"3/4" 8" 16 1/2" 1"4 1/4" 3/4"45" (FROSTED GLASS) 32"W W.C. DOOR 7" 24"D VANITY 21" FROSTED GLASS DOOR (TO TOILET ROOM) 3-T-05 (WALL TILE)8"96" 40"W TOILET ROOM 4 7/8"85 5/8" 36"W TUB WALL 41" 8 5/8"6 1/4" (CLEAR GLASS) 28"W SHWR DOOR 1 3/4" 3 cm 30"W TUB 3 cm19"T TUB20.181"FROSTED GLASS DOOR (TO TOILET ROOM) CLEAR GLASS SHWR. SURROUND & DOOR 3-PLU-15 (TUB) 3-T-05 (WALL TILE) 4.819" 3-ST-05 (DECK/APRON, 3cm) 3-WD-01 3-WD-03 3-WD-01 24"D VANITY60"L BATHTUB 96" 8"1/2" GLS 48"SHOWER (OUTSIDE) 40 3/4"W NICHE 6 3/4" 132"48" 14"T NICHE 34"3-T-05 (WALL TILE) 3-PLU-02 (SINKS) 3-PLU-03 (FAUCETS) 3-ST-03 (VANITY TOP)T.O. COUNTER: 36"3-PLU-15 (TUB) 3-ST-05 (DECK/APRON, 3cm) PENDANT LIGHTS (LIUKU BALL GLASS SHADE PENDANT LIGHT, 3ct) LED BACK-LIT MIRROR (68"W x 42"T) ROUND MAGNIFYING MIRROR DOUBLE VANITY (w/ 4" COUNTER, METAL FRAME, & WOOD DRWRS/SHLF) 5 1/2" 32 1/2" 32 1/2" 5 1/2" 45 5/8" 76" 4 7/8" TOILET ROM 40"W 4" 68"W VANITY/MIRROR 4" 3/4" 8 1/4" 18" 14" 18" 8 1/4" 3/4"8"96" 31.181" 14.444" 30"W TUB19"19"T TUB3 cm3 cmCOUNTER: 36"H 6" 42"T MIRROR 12"UNDER-MOUNT BATHTUB (30"W x 60"L x 19"T, *PLUS 3cm SLAB DECK & APRON) FROSTED GLASS DOOR (TO TOILET ROOM) 3-PLU-01 3-T-05 (WALL TILE) 3-PLU-08 (TUB FILLER) 3-PLU-15 (TUB) 3-PLU-02 (SINKS) 3-PLU-03 (FAUCETS) 3-BA-04 48"D SHWR.96"12"84"T CLEAR SHWR. GLASS 47 1/2" 1/2"GLS.48"3-T-05 (WALL TILE)40"3-PLU-04 51 5/8"W SHOWER 96"34"14"T NICHE 48" 3-T-05 (WALL TILE) 3-PLU-04 12"84"T CLEAR SHWR. GLASS 47 1/2" 1/2"GLS. 96"48" 40 3/4"W NICHE WALL 6 3/4"48" 14"T NICHE 34"RECESSED NICHE (14"T, w/ SLAB SILL & FIELD TILE SIDES/ TOP/BACK) 3-T-05 (WALL TILE) 3-PLU-04 51 5/8" 96"15 5/8" 36"W GLASS (CLEAR) 1 3/4" (CLEAR GLASS) 28"W SHWR DOOR 6 1/4"12"84"T CLEAR SHWR. GLASS CLEAR GLASS SHWR. SURROUND & DOOR 3-T-05 (WALL TILE) 3-PLU-04 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 ARCHITECTUR ® Sara Shalls 1529 Easy Rider Ln#101 Boulder, CO 80304 Ph: 303.595.5235 9/5/2018 9:27:20 PM 3/8" = 1'-0"FOUR SEASONS - VAILSUITE 3101Project Number PD SS 09/05/2018 100% CONSTRUCTION DOCUMENTS UNIT 3101 ELEVATIONS - TOILETS A3-06 FOUR SEASONS - VAIL SS 3/8" = 1'-0" 1 3101 - BATH A3-03 - N ELEVATION 3/8" = 1'-0"2 3101 - BATH A3-03 - E ELEVATION 3/8" = 1'-0" 3 3101 - BATH A3-03 - S ELEVATION 3/8" = 1'-0"4 3101 - BATH A3-03 - W ELEVATION 3/8" = 1'-0"5 3101 - BATH A3-03 - N SHWR 3/8" = 1'-0"6 3101 - BATH A3-03 - E SHWR 3/8" = 1'-0"7 3101 - BATH A3-03 - S SHWR 3/8" = 1'-0"8 3101 - BATH A3-03 - W SHWR 3/8" = 1'-0"9 3101 - BATH A3-10 - N ELEVATION 3/8" = 1'-0"10 3101 - BATH A3-10 - E ELEVATION 3/8" = 1'-0"11 3101 - BATH A3-10 - S ELEVATION 3/8" = 1'-0"12 3101 - BATH A3-10 - W ELEVATION 3/8" = 1'-0" 13 3101 - BATH A3-10 - N SHWR 3/8" = 1'-0"14 3101 - BATH A3-10 - E SHWR 3/8" = 1'-0"15 3101 - BATH A3-10 - S SHWR 3/8" = 1'-0"16 3101 - BATH A3-10 - W SHWR 10/16/18 3/4" 13 1/4" 18" 29" 18" 13 1/4" 3/4"96" PENDANT LIGHTS (LIUKU BALL GLASS SHADE PENDANT LIGHT, 3ct) LED BACK-LIT MIRROR (93"W x 42"T) ROUND MAGNIFYING MIRROR DOUBLE VANITY (w/ 4" COUNTER, METAL FRAME, & WOOD DRWRS/SHLF)36" 36" T COUNTER 24" DROP 10 9/16"45" 45"10 9/16" 111 1/8" 4 7/8"TOILET ROOM 36"W 9 1/16" 93"W VANITY & MIRROR 9 1/16" 3-T-05 (WALL TILE) 3-PLU-02 (SINKS) 3-PLU-03 (FAUCETS) 3-ST-03 (VANITY TOP)42"T BACK-LIT MIRROR 6" T.O. COUNTER: 36" 4"3/4"3/4"DRWRS.8" 16 1/2" 1" SHLF.4 1/4"12"3-BA-04 110 7/8" 24"D VANITY 47 7/8" 36"W BATHTUB 3"96"BATHTUB23"T3 3/4" 36"W DOOR 8 1/8"OVAL BATH TUB (NATIVE TRAILS - "AVALON 72", 72"L x 36"W x 23"T) 3-T-05 (WALL TILE) 3-PLU-06 (TUB FILLER) 3-PLU-05 (TUB) 3-WD-03 3-WD-01 TOILET ROOM 36"W 4 7/8" 111 1/8" 36 1/8"72"L BATHTUB 3"96"BATHTUB23"TOVAL BATH TUB (NATIVE TRAILS - "AVALON 72", 72"L x 36"W x 23"T) 3-PLU-05 (TUB) 3-PLU-06 (TUB FILLER) 3-T-05 (WALL TILE) FLOOR MIRROR (LEANING, 48"W x 72"T, w/ 5"W FRAME) 110 7/8"(CLEAR GLASS) 46" SHOWER 64 7/8" TOILET ROOM 6 3/8" (FROSTED GLASS) 32"W DOOR TO W.C. 26 1/2" 24"D VANITY 3" 36"W BATHTUB 96"12"84"T CLEAR SHWR. GLASS 23"T BATHTUBCLEAR GLASS SHWR. SURROUND & DOOR DOUBLE VANITY (w/ 4" COUNTER, METAL FRAME & WOOD DRWRS/SHLF) FROSTED GLASS DOOR TO TOILET ROOM OVAL BATH TUB (NATIVE TRAILS - "AVALON 72", 72"L x 36"W x 23"T) 3-T-05 (WALL TILE) 3-PLU-02 (SINKS) 3-PLU-03 (FAUCETS) 3-ST-03 (VANITY TOP) 3-PLU-05 (TUB) 3-PLU-06 (TUB FILLER) 40 7/8"96"12"84"T CLEAR SHWR. GLASS 40 3/8" 1/2"GLS. CLEAR GLASS SHWR. SURROUND & DOOR 3-T-05 (WALL TILE) 3-PLU-04 48"40" 46" (CLEAR GLASS) 32"W SHWR. DOOR GLASS 14"96"12"84"T CLEAR SHWR. GLASS CLEAR GLASS SHWR. SURROUND & DOOR 3-T-05 (WALL TILE) 3-PLU-04 40 7/8" 40 3/8"W NICHE 1/2"GLS.96"84"T CLEAR SHWR. GLASS 12"48" 14" 34"RECESSED NICHE (14"T, w/ SLAB SILL & FIELD TILE SIDES/ TOP/BACK) 3-T-05 (WALL TILE) 3-PLU-04 46"W SHOWER96"34"NICHE14"T48" 3-T-05 (WALL TILE) 3-PLU-04 82 3/16"96"24"D VANITY58 3/16" 1/2" GLASS 6 5/8" 36"W DOOR 15 9/16" 39 1/2"W NICHE 40" SHOWER PENDANT LIGHTS (SUSPENDED ROUND GLOBE BULBS, 2ct) RECTANGULAR WALL MIRROR (21"W x 42"T) SINGLE VANITY (w/ 14"T BLOCK SLAB COUNTER, WOOD FRAME & SHLF)34"14"T NICHE 48" RECESSED NICHE (14"T, w/ SLAB SILL & FIELD TILE SIDES/ TOP/BACK) 3-T-02 (WALL TILE) 3-PLU-09 (SINK) 3-ST-02 (VANITY TOP) 3-PLU-16 3-PLU-10 (FAUCET) 72 5/8"96"2" 33"W VANITY 37 5/8"12"42"T MIRROR 6" T.O. COUNTER: 36" 1 1/4" FRAME3 3/4"1" SHLF14 3/4"1 1/4" FRAME14" BLOCK SLABFRAME 1 1/4" 30 1/2" FRAME 1 1/4" MIRROR 21"W PENDANT DROP: 36"3" 3"3" 3" PENDANT LIGHTS (SUSPENDED ROUND GLOBE BULBS, 2ct) RECTANGULAR WALL MIRROR (21"W x 42"T) SINGLE VANITY (w/ 14"T BLOCK SLAB COUNTER, WOOD FRAME & SHLF) 3-T-02 (WALL TILE) 3-PLU-01 3-PLU-09 (SINK) 3-ST-02 (VANITY TOP) 3-BA-08 3-PLU-16 3-PLU-10 (FAUCET) 82 3/16" 96"1/2" GLASS CLEAR GLASS SHWR. SURROUND & DOOR 3-T-02 (WALL TILE) 39 1/2" 40" 3-PLU-11 3-BA-08 3-PLU-0196"12"84"T CLEAR SHWR. GLASS 19 1/8" 10 3/4" (CLEAR) 32"W GLASS DOOR 10 3/4" 53 1/2" SHOWER 72 5/8" CLEAR GLASS SHWR. SURROUND & DOOR 3-T-02 (WALL TILE)96"1/2" GLS. 39 1/2"W NICHE 40" SHOWER34"NICHE14"T48"CLEAR GLASS SHWR. SURROUND & DOOR RECESSED NICHE (14"T, w/ SLAB SILL & FIELD TILE SIDES/ TOP/BACK) 3-T-02 (WALL TILE) 53 1/2" SHOWER96"12"84"T CLEAR SHWR. GLASS 10 3/4" (CLEAR GLASS) 32"W SHWR. DOOR 10 3/4" CLEAR GLASS SHWR. SURROUND & DOOR 3-PLU-11 96"1/2" GLASS84"T GLASS 12"CLEAR GLASS SHWR. SURROUND & DOOR 3-T-02 (WALL TILE) 39 1/2" 40"48"3-PLU-11 53 1/2"W SHWR.96"34"NICHE14"T48" 3-T-02 (WALL TILE) 3-PLU-11 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 ARCHITECTUR ® Sara Shalls 1529 Easy Rider Ln#101 Boulder, CO 80304 Ph: 303.595.5235 9/5/2018 9:27:29 PM 3/8" = 1'-0"FOUR SEASONS - VAILSUITE 3101Project Number PD SS 09/05/2018 100% CONSTRUCTION DOCUMENTS UNIT 3101 ELEVATIONS - TOILETS A3-07 FOUR SEASONS - VAIL SS 3/8" = 1'-0"1 3101 - BATH A3-20 - N ELEVATION 3/8" = 1'-0"2 3101 - BATH A3-20 - E ELEVATION 3/8" = 1'-0"3 3101 - BATH A3-20 - S ELEVATION 3/8" = 1'-0"4 3101 - BATH A3-20 - W ELEVATION 3/8" = 1'-0"5 3101 - BATH A3-20 - N SHWR 3/8" = 1'-0"6 3101 - BATH A3-20 - E SHWR 3/8" = 1'-0"7 3101 - BATH A3-20 - S SHWR 3/8" = 1'-0"8 3101 - BATH A3-20 - W SHWR 3/8" = 1'-0"9 3101 - BATH A3-26 - N ELEVATION 3/8" = 1'-0"10 3101 - BATH A3-26 - E ELEVATION 3/8" = 1'-0"11 3101 - BATH A3-26 - S ELEVATION 3/8" = 1'-0"12 3101 - BATH A3-26 - W ELEVATION 3/8" = 1'-0"13 3101 - BATH A3-26 - N SHWR 3/8" = 1'-0"14 3101 - BATH A3-26 - E SHWR 3/8" = 1'-0"15 3101 - BATH A3-26 - S SHWR 3/8" = 1'-0"16 3101 - BATH A3-26 - W SHWR 10/16/18 186 3/4"W UPHOLSTERED HEADBOARD 19 5/16"36"W NIGHTSTAND 2" 72"W BED 2" 36"W NIGHTSTANDT.O. HEADBOARD: 54"16"T NIGHTSTANDS8"110"19 7/16"56"T VINYL WALL FINISH KING BED (w/ UPHOLSTERED HEADBOARD) VINYL WALL COVERING (ABOVE HEADBOARD) 3/4" 17 1/4"W DRWR 17 1/4"W DRWR 3/4" 3/4" 17 1/4"W DRWR17 1/4"W DRWR 3/4"3/4" FRAMESHLF7 1/4"TDRWRS8"T3-WC-03 DRAPERY VALANCE (WOOD, 12"D x 8"T, w/ LUTRON CEILING TRACKS) 3-WD-07 (2) FLOATING NIGHTSTANDS & TABLE LAMPS (36"W x 20"D x 16"T) LUTRON CONTROL PANELS (2ct)110"150 1/2" 83"L BED 45 1/2" DRESSER 18"DT.O. HEADBOARD: 54" T.O. MATTRESS:24"4" BUMP-OUT DRESSER (6"W x 18"D x 32"T) WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI- RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) DRAPERY VALANCE (WOOD, 12"D x 8"T, w/ LUTRON CEILING TRACKS) 3-WD-07 3-WC-01 6-1/2"H BASE3" 80" 186 3/4" 110"44" 33"T TV 33"59 5/8" 67 1/2"W BUMP-OUT 59 5/8" 3/4" WOOD 66"W DRESSER/TV 3/4" WOOD 32"T DRESSER 12"DRAPERY VALANCE (WOOD, 12"D x 8"T, w/ LUTRON CEILING TRACKS) DRESSER (6"W x 18"D x 32"T) WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI-RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) DINING TABLE & CHAIRS (30"Ø x 30"T) 3-WC-01 3-WC-01 3-WD-08 3-WD-07 LOUNGE CHAIR FLOOR LAMP (16"Ø SHADE) 6-1/2"H BASE 3-WC-01 3-WD-02 150 1/2" 150 1/2"110"DRESSER 18"D 45 1/2" 83"L BED T.O. HEADBOARD: 54" DRESSER (66"W x 18"D x 32"T) WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI- RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) 4" BUMP-OUT 3-WC-01 6-1/2"H BASE 80" 3" 3-WD-03 3-WD-02 3-WD-08 (VINYL WALL FINISH) 56"54"T HEADBOARD110"192 3/4"W UPHOLSTERED HEADBOARD 60 3/8" 72"W BED 60 3/8"2" 36"W NIGHTSTAND 22 7/16" 2" 36"W NIGHTSTAND22 3/8" 3/4" 17 1/4"W DRWR 17 1/4"W DRWR 3/4" 3/4" 17 1/4"W DRWR 17 1/4"W DRWR 3/4" KING BED (w/ UPHOLSTERED HEADBOARD) VINYL WALL COVERING (ABOVE HEADBOARD) DRAPERY VALANCE (WOOD, 12"D x 8"T, w/ LUTRON CEILING TRACKS) 3-WC-03 3-WD-07 (2) FLOATING NIGHTSTANDS & TABLE LAMPS (36"W x 20"D x 16"T) LUTRON CONTROL PANELS (2ct)3/4"SHELF7 1/4"DRWRS 8" NIGHSTANDS16"T8" 24"83"L BED 48 5/8" 110"T.O. HEADBOARD: 54"DRESSER 18"D 4" BUMP-OUT 153 5/8" DRESSER (6"W x 18"D x 32"T) WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI- RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) 3-WC-01 3-WD-07 DRAPERY VALANCE (WOOD, 12"D x 8"T, w/ LUTRON CEILING TRACKS) 6-1/2"H BASE3" 80" 192 3/4"44" 33"T TV (*VERIFY) 33"62 5/8"67 1/2"W BUMP-OUT 62 5/8" 110"3/4" WOOD 66"W DRESSER/TV 3/4" WOOD 32"T DRESSER 12"LOUNGE CHAIR FLOOR LAMP (16"Ø SHADE) DRESSER (6"W x 18"D x 32"T) DINING TABLE & CHAIRS (30"Ø x 30"T) DRAPERY VALANCE (WOOD, 12"D x 8"T, w/ LUTRON CEILING TRACKS) WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI-RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) 3-WC-01 3-WC-01 3-WD-08 3-WC-01 6-1/2"H BASE 3-WC-01 3-WD-02 153 5/8" DRESSER 18"D 48 5/8" 83"L BED 153 5/8"110" T.O. HEADBOARD: 54"DRESSER (66"W x 18"D x 32"T) 4" BUMP-OUT WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI- RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) 3-WC-01 6-1/2"H BASE 80" 3" 3-WD-03 3-WD-02 3-WD-08 186 3/8" 174 3/8"W HEADBOARD BUMP-OUT 12" 13 3/16"36"W NIGHTSTAND 2" 72"W BED 2" 36"W NIGHTSTAND13 3/16" 42"T VINYL WALL FINISH54"T HEADBOARDNIGHTSTANDS16"T8" 14"96" (2) FLOATING NIGHTSTANDS & TABLE LAMPS (36"W x 20"D x 16"T) KING BED (w/ UPHOLSTERED HEADBOARD) 3/4" 17 1/4"W DRWR 17 1/4"W DRWR 3/4" 3/4" 17 1/4"W DRWR17 1/4"W DRWR 3/4"3/4" FRAMESHLF7 1/4"TDRWRS8"T3-WC-03 LUTRON DRAPERY TRACKS (CEILING MOUNTED) 6-1/2"H BASE VINYL WALL COVERING (ABOVE HEADBOARD) LUTRON CONTROL PANELS (2ct) 3-WD-02T.O. HEADBOARD: 54"T.O. MATTRESS:24"MATTRESS12"BASE 12" 14"96" 152 85/256" 83"L BED 47 85/256" DRESSER 18"D 4" BUMP-OUT 3-WC-01 DRESSER (6"W x 18"D x 32"T) WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI- RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) SHADE POCKET LUTRON DRAPERY TRACKS (CEILING MOUNTED) 6-1/2"H BASE3" 80" 186 3/8"96" 14"44" 33"T TV 19"53 7/16"67 1/2"W BUMP-OUT65 7/16" SHADE POCKETS LOUNGE CHAIR FLOOR LAMP 3/4" WOOD 66"W DRESSER/TV 3/4" WOOD 32"T DRESSER 12"DRESSER (6"W x 18"D x 32"T) WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI-RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) 3-WC-01 3-WC-01 3-WD-08 LUTRON DRAPERY TRACKS (CEILING MOUNTED) 6-1/2"H BASE 3-WC-01 3-WD-02 152 85/256"14"96" T.O. HEADBOARD: 54"T.O. NIGHTSTAND: 24"NIGHTSTAND16"T8" 47 85/256" 83"L BED NIGHTSTAND 20"D DRESSER (66"W x 18"D x 32"T) 4" BUMP-OUT DRESSER 18"D WALL BUMP-OUT (67-1/2"W x 4"D, w/ 3/4" WOOD SIDE PANELS, SEMI- RECESSED 66" TV & 32"W x 24"T OPENING IN BACK WALL FOR MOUNT) 3-WC-01 6-1/2"H BASE 80" 3" 3-WD-08 3-WD-03 3-WD-02 70 11/16"W COFFEE BAR96"2" TOE-KICKFRIDGE DRWR18"T DRWR/DRWRS7"T DRWRS7"T2" CTFRIDGE DRWR 35 11/32"W DRWRS/35 11/32"W DRWRS T.O. COUNTER: 36" 20"2" SHLF10" 28"T UPPER CABINETCOFFEE BAR (70-11/16"W x 24"D, w/ DRWRS & FRIDGE DRWR) 13"D UPPER CAB (w/ 2" THICK FLOATING WOOD SHELF BELOW) ANTIQUE GLASS BACK-PANEL 3-GL-01 3-WD-04 3-WD-04 3-ST-01 3-HWR-01 3-AP-0168"W COFFEE BAR96"FRIDGE DRWR 34"W DRWRS/34"W DRWRS 2" TOE-KICKFRIDGE DRWR18"T DRWRS/DRWRS7"T DRWRS7"T2" CTT.O. COUNTER: 36" 20"2" SHLF10" 28"T UPPER CABINETCOFFEE BAR (68"W x 24"D, w/ DRWRS & FRIDGE DRWR) 13"D UPPER CAB (w/ 2" THICK FLOATING WOOD SHELF BELOW) ANTIQUE GLASS BACK-PANEL 3-WD-04 3-WD-04 3-ST-01 3-GL-01 3-HWR-01 3-AP-01 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 ARCHITECTUR ® Sara Shalls 1529 Easy Rider Ln#101 Boulder, CO 80304 Ph: 303.595.5235 9/5/2018 9:27:34 PM 3/8" = 1'-0"FOUR SEASONS - VAILSUITE 3101Project Number PD SS 09/05/2018 100% CONSTRUCTION DOCUMENTS UNIT 3101 ELEVATIONS - BEDROOMS & COFFEE BARS A3-08 FOUR SEASONS - VAIL SS 3/8" = 1'-0"1 3101 - BED A3-05 - N ELEVATION 3/8" = 1'-0"2 3101 - BED A3-05 - E ELEVATION 3/8" = 1'-0"3 3101 - BED A3-05 - S ELEVATION 3/8" = 1'-0"4 3101 - BED A3-05 - W ELEVATION 3/8" = 1'-0"5 3101 - BED A3-13 - N ELEVATION 3/8" = 1'-0"6 3101 - BED A3-13 - E ELEVATION 3/8" = 1'-0"7 3101 - BED A3-13 - S ELEVATION 3/8" = 1'-0"8 3101 - BED A3-13 - W ELEVATION 3/8" = 1'-0"9 3101 - BED A3-23 - N ELEVATION 3/8" = 1'-0"10 3101 - BED A3-23 - E ELEVATION 3/8" = 1'-0"11 3101 - BED A3-23 - S ELEVATION 3/8" = 1'-0"12 3101 - BED A3-23 - W ELEVATION 3/8" = 1'-0"13 3101 - HALL A3-02 - COFFEE BAR 3/8" = 1'-0"14 3101 - HALL A3-11 - COFFEE BAR 10/16/18 240" 4" (TO BEDROOM) 36"W DOOR 56" 88"W SOFA 56"14"96" 50 1/2"W COFFEE TABLE OVAL COCKTAIL TABLE (MATTALIANO - "ETTORE," 50-1/2"W x 23"D x 16"H) SOFA (88"L x 36"D)LOUNGE CHAIR (31"L x 30"D) SIDE TABLE (24"Ø) FLOOR LAMP (20"Ø SHADE) TABLE LAMP 6-1/2"H BASE SHADE POCKET LUTRON DRAPERY TRACKS (CEILING MOUNTED) 3-WC-01 3-WD-03 3-WD-01 3-WD-02 ART LIGHT14"96" 155 107/256" 36"D SOFA 18 1/2" COFFEE TABLE 23"D 41 235/256" HEARTH 14 7/8" F/P BUMP-OUT 21 1/8" OVAL COCKTAIL TABLE (MATTALIANO - "ETTORE," 50-1/2"W x 23"D x 16"H) SOFA (88"L x 36"D) 60" LINEAR FIREPLACE (+/- 20-1/8"D BUMP- OUT, w/ 12"x24" DUNE STONE & SLAB HEARTH) 6-1/2"H BASE FLOOR LAMP (20" SHADE) SHADE POCKET LUTRON DRAPERY TRACKS (CEILING MOUNTED) 3-WD-03 3-WD-02 3-AP-02HEARTH12"H 8"F/P GLASS16"T 8" 33"T TV72" W F/P BUMP-OUT 54" W DRY BAR 7 1/2" 57"W TV 7 1/2" 57 11/16"W GLASS F/P OPENING 14 5/16" BENCH 18"D51 1/4" 42"L OVAL TABLE 19" 26"2" 14" 3" 24" 2"45" 51"19"96"WALL SCONCE (VISUAL COMFORT - "VENICE SCONCE", 12.5"W x 12.5"T x 4"D, BACKPLATE: 8.75" SQ.) 60" LINEAR FIREPLACE (+/- 20-1/8"D BUMP-OUT, w/ 12"x24" DUNE STONE & SLAB HEARTH) WET BAR (54"W x 18"D DRWRS w/ FRIDGE DRWR & BAR SINK, 13"D UPPER CAB, & 2" THICK FLOATING WOOD SHELF ABOVE) TV WALL (SETBACK FROM F/P WALL, w/ 65" TV) BUILT-IN SEATING (69-1/4"L x 48-3/4"W (OVERALL), SEAT: 19"H, BACK: 24"T, w/ 42"L x 24"W OVAL TABLE & 18"D BENCH) FRIDGE DRWR. 24"W DRWRS/30"W DRWRS. 72" W TV WALL 267 1/4" 69 1/4" W BANQUETTE ANTIQUE MIRROR WALL FINISH 3-GL-01 3-WD-04 3-WD-04 3-HWR-01 3-ST-01 3-WC-02 3-ST-01 3-T-03 3-PLU-14 3-AP-01 3-AP-02 3-PLU-1314"96" 155 107/256" 36" 41 235/256" COFFEE TABLE 23"D 18 1/2" 36"D SOFA OVAL COCKTAIL TABLE (MATTALIANO - "ETTORE," 50-1/2"W x 23"D x 16"H) SOFA (88"L x 36"D) LOUNGE CHAIR (31"L x 30"D) 60" LINEAR FIREPLACE (+/-20-1/8"D BUMP- OUT, w/ 12"x24" DUNE STONE & SLAB HEARTH) ANTIQUE MIRROR WALL FINISH 3-GL-01 TABLE LAMP 6-1/2"H BASE 3-WD-03 3-WD-01 3-WD-02 3-AP-02 84 7/8"96"24"2"70" 12"60 7/8" 12" LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) 64 7/8" BUILT-IN 20"D CLOSET BUILT-IN (46"W x 20"D x 72"T (OVERALL), w/ 17"W DRWRS/SHELVES, 28"W x 24"T STORAGE BENCH, 1" THICK PANELS/SHELVES & 4"T TOE-KICKS) 6-1/2"H BASE 12"52 7/8" 12"14 7/16" 24" 14 7/16" WALL MIRROR (24"W x 66"T) 3-WD-09 3-WD-02 64 1/8"96"24"2"4"66"LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) 6-1/2"H BASE 3-WD-02 84 7/8"96"70"2"24"12" 60 7/8" 12" 62 7/16"0"W DBL. CLOS. DOOR 22 7/16" LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) 6-1/2"H BASE 3-WD-02 64 1/8"96" 66" 4"2"24"72"T BUILT-IN 36"T SHELVES36"T DRWRS. 2"10.333"1" 10.333"1"10.333"1"DRWR6"DRWR6" DRWR10"DRWR10"TOE4"18 1/8" 46"W BUILT-IN 28"W STORAGE BENCH 18" LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) CLOSET BUILT-IN (46"W x 20"D x 72"T (OVERALL), w/ 17"W DRWRS/SHELVES, 28"W x 24"T STORAGE BENCH, 1" THICK PANELS/SHELVES & 4"T TOE-KICKS) 1" PANEL 26"W OPENING 1" PANEL 1" PANEL SHELVES 16"W DRWRS/ 1" PANELSTORAGE BENCH 24"T1" PANEL 18"T OPENING1" PANELTOE4"6-1/2"H BASE 3-WD-02 3-WD-09 74 7/8"96"24"2" 70" 2"10.333"1" 10.333"1"10.333"1"DRWR.6"DRWR.6" DRWR. 10" DRWR.10"TOE4"STORAGE BENCH24"T36"T SHELVES 36"T DRWRS. 72"T BUILT-IN 18"44 7/8" 12" 28 7/8" 46"W BUILT-IN 28"W STORAGE BENCH 18" LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) CLOSET BUILT-IN (46"W x 20"D x 72"T (OVERALL), w/ 17"W DRWRS/SHELVES, 28"W x 24"T STORAGE BENCH, 1" THICK PANELS/SHELVES & 4"T TOE-KICKS)1" PANEL18"T OPENING1" PANELTOE4"1" PANEL 26"W OPENING 1" PANEL 1" PANEL SHELVES 16"W DRWRS/ 1" PANEL6-1/2"H BASE 3-WD-02 3-WD-09 62 3/4"96"70"2"24"72"T BUILT-IN BUILT-IN 20"D 42 3/4" 12" 50 3/4" LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) CLOSET BUILT-IN (46"W x 20"D x 72"T (OVERALL), w/ 17"W DRWRS/SHELVES, 28"W x 24"T STORAGE BENCH, 1" THICK PANELS/SHELVES & 4"T TOE-KICKS) 6-1/2"H BASE 9 3/8" 24"W MIROR 9 3/8" WALL MIRROR (24"W x 66"T)12" 66"T MIRROR 18"3-WD-02 3-WD-09 74 7/8"96"70" 2" 24"34 7/8"34"W DOOR 6" 62 7/8" 12" LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) 6-1/2"H BASE 3-WD-02 62 3/4"96"24"2"70"50 3/4" 12" LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) 6-1/2"H BASE 3-WD-02 24"2" 70" 57" 12" 96"LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) CLOSET BUILT-IN (46"W x 20"D x 72"T (OVERALL), w/ 17"W DRWRS/SHELVES, 28"W x 24"T STORAGE BENCH, 1" THICK PANELS/SHELVES & 4"T TOE-KICKS) 18" 41" 46"W BUILT-IN 28"W STORAGE BENCH 18"36"T SHELVES36"T DRWRS. 72"T BUILT-IN2"10.333"1" 10.333" 1" 10.333"1"DRWR.6"DRWR.6" DRWR. 10" DRWR.10"TOE4"87"STORAGE BENCH24"T1" PANEL SHELVES 16"W DRWRS/ 1" PANEL1" PANEL 26"W OPENING 1" PANEL 1" PANELOPENING18"T1" PANELTOE4"6-1/2"H BASE 3-WD-02 3-WD-09 12" 82 5/8" 96"24"2"70"LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) CLOSET BUILT-IN (46"W x 20"D x 72"T (OVERALL), w/ 17"W DRWRS/SHELVES, 28"W x 24"T STORAGE BENCH, 1" THICK PANELS/SHELVES & 4"T TOE-KICKS) BUILT-IN 20"D 74 5/8" 94 5/8" 6-1/2"H BASE 3-WD-09 3-WD-02 14 7/8"72 1/8" 87" 96"70" 2"24"12" LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) 6-1/2"H BASE 24"W MIRROR 1 1/16" 28 1/8"36"W DOOR 8" WALL MIRROR (24"W x 66"T)12" 66"T MIRROR 18"25" 69 5/8"96"57 5/8" 12" 24"2"70" LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) 94 5/8" 6-1/2"H BASE 51 7/16"96" 66"4" 2"24"LIGHT VALANCE (2" TALL, TYPICAL @ ALL CLOSET SHELVING) 6-1/2"H BASE 3-WD-02 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 ARCHITECTUR ® Sara Shalls 1529 Easy Rider Ln#101 Boulder, CO 80304 Ph: 303.595.5235 9/5/2018 9:27:37 PM 3/8" = 1'-0"FOUR SEASONS - VAILSUITE 3101Project Number PD SS 09/05/2018 100% CONSTRUCTION DOCUMENTS UNIT 3101 ELEVATIONS - LIVING ROOM & CLOSETS A3-09 FOUR SEASONS - VAIL SS 3/8" = 1'-0" 1 3101 - LVNG A3-24 - N ELEVATION 3/8" = 1'-0"2 3101 - LVNG A3-24 - E ELEVATION 3/8" = 1'-0"3 3101 - LVNG A3-24 - S ELEVATION 3/8" = 1'-0"4 3101 - LVNG A3-24 - W ELEVATION 3/8" = 1'-0"5 3101 - CLOSET A3-04 - N ELEVATION 3/8" = 1'-0"6 3101 - CLOSET A3-04 - E ELEVATION 3/8" = 1'-0"7 3101 - CLOSET A3-04 - S ELEVATION 3/8" = 1'-0"8 3101 - CLOSET A3-04 - W ELEVATION 3/8" = 1'-0"9 3101 - CLOSET A3-12 - N ELEVATION 3/8" = 1'-0"10 3101 - CLOSET A3-12 - E ELEVATION 3/8" = 1'-0"11 3101 - CLOSET A3-12 - S ELEVATION 3/8" = 1'-0"12 3101 - CLOSET A3-12 - W ELEVATION 3/8" = 1'-0"13 3101 - CLOSET A3-22 - N ELEVATION 3/8" = 1'-0"14 3101 - CLOSET A3-22 - E ELEVATION 3/8" = 1'-0"15 3101 - CLOSET A3-22 - S ELEVATION 3/8" = 1'-0"16 3101 - CLOSET A3-22 - W ELEVATION 3/8" = 1'-0"17 3101 - CLOSET A3-25 - S ELEVATION 10/16/18 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 ARCHITECTUR ® Sara Shalls 1529 Easy Rider Ln#101 Boulder, CO 80304 Ph: 303.595.5235 9/5/2018 9:27:40 PMFOUR SEASONS - VAILSUITE 3101Project Number Author Checker 09/05/2018 100% CONSTRUCTION DOCUMENTS UNIT 3101 SCHEDULES A3-10 FOUR SEASONS - VAIL Approver 10/16/18 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 ARCHITECTUR ® Sara Shalls 1529 Easy Rider Ln#101 Boulder, CO 80304 Ph: 303.595.5235 9/5/2018 9:27:46 PMFOUR SEASONS - VAILSUITE 3101Project Number PD SS 09/05/2018 100% CONSTRUCTION DOCUMENTS UNIT 3101 3D PERSPECTIVES- LIVING ROOM & MASTER BATH A3-11 FOUR SEASONS - VAIL SS 1 3D VIEW (FIREPLACE WALL) 1 2 3D VIEW (FIREPLACE WALL) 2 3 3D VIEW (VANITY)4 3D VIEW (VANITY) 2 10/16/18 KEY PLAN INFILL STONE VENEER - "OKLAHOMA STONE" CUSTOM MIX TO MATCH SURROUNDING STONE - RE: SPECS NEW WINDOWS TO MATCH EXISTING STYLE RE: SPECS NEW WINDOWS TO MATCH EXISTING STYLE RE: SPECS AREA OF WORK A3-10 4 Sim 6"1/2"3/8" SHIM FLEXIBLE FLASHING 3X8 SHAPED FRT WOOD SHEET METAL FLASHING GYP SHEATHING LAP FLEXIBLE FLASHING OVER WALL MEMBRANE 6" LAP VAPOR BARRIER OVER FLEXIBLE FLASHING SEALANT ROD WOOD TRIM, S.I.D. ROD AND SEALANT 6"2 1/2"3" CONC. SLAB WOOD TRIM, S.I.D. 3/8" SHIM LAP VAPORT BARRIER OVER FLEXIBLE FLASHING FLEXIBLE FLASHING ROD AND SEALANT 3X SHAPED FRT WOOD SILL BELOW AT JAMB 3X3X1/4" STEEL ANGLE SHEATHING PAPER STONE AT JAMB SHOWN DASHED PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:46 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/09/13 PERMIT SUBMITTAL EXTERIOR ELEVATIONS & WINDOW REPLACEMENT A3-20 FOUR SEASONS RESORT AT VAIL OZ 3/16" = 1'-0"2 ENLARGED AREA OF WORK 1/16" = 1'-0" 1 PROPOSED EXTERIOR ELEVATION - WEST window schedule Type Mark R.O. Manufacturer Model Material Frame Finish - Exterior Frame Finish - Interior Glazing Head Height Comments U-Value SHGCWidth Height Thickness Type 1 6' - 0" 5' - 9" Sierra Pacific Clad Aspen 2.0 Casement Aluminum Clad Wood Bronze 024 TBD by InteriorsDual Pane Insulated Cardinal LoE2 272 8' - 0" Exterior Style to Match existing windows 0.33 0.29 3" = 1'-0"3 WINDOW SILL 3" = 1'-0"4 WINDOW HEAD/JAMB 10/16/18 MECHANICAL EQUIPMENT WIRING AND CONNECTIONS ITEM FURNISHED UNDER SET IN PLACE OR MTD. UNDER WIRED / CONNECTED UNDER 1.EQUIPMENT MOTORS AND THERMAL OVERLOADS, RESISTANCEHEATERS MD MD ED 2.VFDs, MOTOR CONTROLLERS; MAGNETIC STARTERS, REDUCED VOLTAGE STARTERS AND OVERLOAD RELAYS MD ED(a) ED 3. DISCONNECT SWITCHES (FUSED OR NON-FUSED), HP RATEDSWITCHES, THERMAL OVERLOAD SWITCHES AND FUSES, AND MANUAL OPERATING SWITCHES ED(a) ED(a) ED 4. PUSHBUTTON STATIONS, PILOT LIGHTS, MULTI-SPEED SWITCHES, FLOAT SWITCHES, THERMOSTATS, CONTROLRELAYS, TIMECLOCKS, CONTROL TRANSFORMERS, CONTROL PANELS, MOTOR VALVES, DAMPER ACTUATORS, SOLENOID VALVES, EP AND PE SWITCHES AND INTERLOCKS MD MD MD(b) 5.120 VOLT POWER FOR BAS PANELS, FIRE PROTECTION AND BOILER CONTROLS ED ED ED 6. FIRE/SMOKE DAMPERS AND ELEVATOR VENT DAMPERS MD MD ED(c) MD = MECHANICAL DIVISION ED = ELECTRICAL DIVISION NOTES: ( a ) IF FURNISHED AS PART OF FACTORY-WIRED EQUIPMENT, THEN WIRING AND CONNECTIONS ONLY BY ED ( b ) IF ANY OF THESE DEVICES CARRY THE FULL LOAD CURRENT TO ANY MOTOR THEY SHALL BE CONNECTED BY ED. CONTROL DEVICES CARRYING FULL LOAD CURRENT FURNISHED BY MD AND WIRED BY ED SHALL BE LOCATED AT THE DEVICE BEING CONTROLLED, UNLESS SHOWN ON DRAWINGS OR MUTUAL AGREEMENT IS MADE BETWEEN THE CONTRACTORS WITH NO CHANGE IN THE CONTRACT PRICE. ( c ) WIRING FROM ALARM CONTACTS TO ALARM SYSTEM BY ED; ALL CONTROL FUNCTION WIRING BY MD. DUCT DETECTORSFURNISHED BY ED, SET IN PLACE BY MD GENERAL NOTE: THE ABOVE LIST DOES NOT ATTEMPT TO INCLUDE ALL COMPONENTS. ALL ITEMS NECESSARY FOR A COMPLETE SYSTEM SHALL BE INCLUDED IN THE BASE CONTRACT. PANEL: PP-RC2A VOLTAGE: 120/208V, 3PH, 4W MINIMUM BUS: 225 LOCATION: STORAGE 304 MAIN: 225/3 CB MOUNTING: SURFACE MINIMUM AIC: 10,000 NO.LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B C POLE TRIP A B C TRIP POLE A B C 1 1080 R RCPT UNIT 1 1 20 + 20 1 SPARE 2 3 682 L BATH 1 UNIT 1 1 20 + 20 1 SPARE 4 5 389 L BATH 2 UNIT 1 1 20 + 20 1 SPARE 6 7 300 E FCU UNIT 1 1 20 + 20 1 SPARE 8 9 1080 R BDR UNIT 1 1 20 + 20 1 SPARE 10 11 400 E DRAPERY UNIT 1 1 20 + 20 1 SPARE 12 13 1062 L LTG UNIT 1 1 20 + 20 1 SPARE 14 15 1440 R RCPT UNIT 2 1 20 + 20 1 SPARE 16 17 850 L BATH UNIT 2 1 20 + 20 1 SPARE 18 19 640 L LTG UNIT 2 1 20 + 20 1 SPARE 20 21 300 E FCU UNIT 2 1 20 + 20 1 SPARE 22 23 200 E DRAPERY UNIT 2 1 20 + 20 1 SPARE 24 25 1260 R RCPT UNIT 3 1 20 + 20 1 SPARE 26 27 850 L BATH UNIT 3 1 20 + 20 1 SPARE 28 29 640 L LTG UNIT 3 1 20 + 20 1 SPARE 30 31 300 E FCU UNIT 3 1 20 + 20 1 SPARE 32 33 200 E DRAPERY UNIT 3 1 20 + 20 1 SPARE 34 35 300 E F/S DAMPERS UNITS 1-3 1 20 + 20 1 SPARE 36 37 SPARE 1 20 + 20 1 SPARE 38 39 SPARE 1 20 + 20 1 SPARE 40 41 SPARE 1 20 + 20 1 SPARE 42 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. CONFIRM UNIT NUMBERS WITH OWNER PRIOR TO (L) LIGHTING 5113 5113 125% 6391 INSTALLING FINAL PANEL SCHEDULE. (R) RECEPTACLES 4860 4860 NEC 220 4860 B. (LM) LARGEST MOTOR 0 0 25% 0 (M) MOTORS (ALL) 0 0 100% 0 (E) EQUIPMENT 2000 2000 100% 2000 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 (1) PANEL TOTAL (KVA): 13.3 (2) (3) PANEL TOTAL (A): 37 (4) (5) WIRING SCHEDULE - COPPER AMPS (2WG) (3WG) (4WG) 1Ø, 2 WIRE, GROUND 1Ø, 3 WIRE, GROUND OR 3Ø, 3 WIRE, GROUND 3Ø, 4 WIRE, GROUND 225 (2#4/0 & 1#4 G) 2"C (3#4/0 & 1#4 G) 2"C (4#4/0 & 1#4 G) 2 1/2"C CONDUCTOR SIZES ARE BASED ON 60° TERMINATIONS LESS THAN 100A AND 75° TERMINATIONS GREATER THAN 100A CONDUIT SIZES ARE BASED ON NEC TABLE 4 (RNC) AND TABLE 5 (THHN INSULATION). ELECTRICAL SYSTEMS LEGEND NOTE: ALL SYMBOLS SHOWN ON LEGEND ARE NOT NECESSARILY USED. ABBREVIATIONS AFC ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AL ALUMINUM AP ACCESS POINT AWG AMERICAN WIRE GAUGE BAS BUILDING AUTOMATION SYSTEM BMS BUILDING MANAGEMENT SYSTEM C CONDUIT CATV COMMUNITY (CABLE) ANTENNA TELEVISION SYSTEM CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CPU CENTRAL PROCESSING UNIT CT CURRENT TRANSFORMER DISP GARBAGE DISPOSAL DW DISHWASHER (E) EXISTING EM EMERGENCY EWC ELECTRIC WATER COOLER FA FIRE ALARM FBO FURNISHED BY OTHERS GC GENERAL CONTRACTOR GFI GROUND FAULT CIRCUIT INTERRUPTER GRD GROUND IAW IN ACCORDANCE WITH IC INTERMEDIATE CROSS-CONNECT IDF INTERMEDIATE DISTRIBUTION FRAME IG ISOLATED GROUND IR INFRARED LAN LOCAL AREA NETWORK MDF MAIN DISTRIBUTION FRAME (N) NEW NIC NOT IN CONTRACT NL NIGHT LIGHT NTS NOT TO SCALE OC ON CENTER PA PUBLIC ADDRESS REF REFRIGERATOR UNO UNLESS NOTED OTHERWISE V VOLT W WATT WAN WIDE AREA NETWORK WAP WIRELESS ACCESS POINT WLAN WIRELESS LOCAL AREA NETWORK WP WEATHERPROOF +18" MOUNTING HEIGHT TO CENTERLINE OF DEVICE ABOVE FINISH FLOOR (VERIFY W/ ARCH ELEVATIONS) ATS S S S S POWER SYMBOLS SINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE GFCI DUPLEX RECEPTACLE DUPLEX RECEPTACLE; HALF SWITCHED ISOLATED GROUND DUPLEX RECEPTACLE WALL MOUNTED SPECIAL OUTLET AS NOTED SPECIAL OUTLET AS NOTED JUNCTION BOX WALL MOUNTED JUNCTION BOX FLOOR MOUNTED JUNCTION BOX DUPLEX RECEPTACLE MOUNTED ABOVE COUNTERC FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM DIVISION 15 EQUIPMENT POWER CONNECTION FUSED DISCONNECT NON FUSED DISCONNECT MOTOR STARTER ENCLOSED CIRCUIT BREAKER PULL BOX PUSH BUTTON TRANSFORMER PANELBOARD OR LOADCENTER CONTACTOR ELECTRIC MOTOR METER THERMOSTAT AUTOMATIC TRANSFER SWITCH CIRCUIT HOMERUN CONDUIT RUN CONDUIT RUN BELOW GRADE CONDUIT UP CONDUIT DOWN TIMER SWITCH MULTI-OUTLET PLUG STRIP TIME CLOCK PHOTO-CELL SWITCH THERMAL OVERLOAD SWITCH VARIABLE SPEED SWITCH KEY SWITCHK V T PC TC TS T C T PB CB N - J J J DL LV OS OS OS S S S S S S S S LIGHTING FIXTURE SYMBOLS RECESSED LIGHTING FIXTURE WALL MOUNTED LIGHT WALL MOUNTED UP-LIGHT PENDANT MOUNTED LIGHT SURFACE MOUNTED LIGHT DIRECTIONAL/ADJUSTABLE RECESSED LIGHTING FIXTURE MONO-POINT LIGHTING FIXTURE RECESSED STEP LIGHT FLUORESCENT STRIP LIGHT WALL MOUNTED LINEAR FLUORESCENT LIGHT RECESSED OR SURFACE MOUNTED FLUORESCENT TROFFER FIXTURE WITH EMERGENCY BACKUP OR ON EM CIRCUIT WALL MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN EMERGENCY LIGHTS CEILING MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH DOOR JAMB SWITCH LIGHTING CONTROL SYMBOLS EXTERIOR POLE MOUNTED LIGHT EXTERIOR POST (BOLLARD) MOUNTED LIGHT DAYLIGHT PHOTO SENSOR KEY SWITCH VARIABLE SPEED SWITCH DIMMER THREE-WAY DIMMER LOW VOLTAGE SWITCH WALL OCCUPANCY SENSOR/SWITCH THERMAL OVERLOAD SWITCH OCCUPANCY SENSOR - WALL MOUNTED OCCUPANCY SENSOR - CORRIDOR CEILING MOUNTED 3 T O D 3 D V K J 4 OCCUPANCY SENSOR - CEILING MOUNTED C NOTES: LIGHT LINEWEIGHT INDICATES EXISTING. HATCHED AREAS INDICATE DEMOLITION. 'C' ADJACENT TO A DEVICE INDICATES MOUNTING ABOVE COUNTERTOP. - - - ISSUE LOG KEY: '√ ' ' ' ' * ' ISSUED AS PART OF SETNOT PART OF SET ISSUED FOR INFORMATION ONLY (E)DP- RC3 1000A (E)DP- OA2 3000A (E)T TO MSB-A 225(4WG) LEVEL 3 LEVEL 21000kVA PP- RC3.1 225A 225(4WG)RELOCATE PANEL PP-RC2A TO STORAGE ACROSS THEHALL. INSTALL NEW PULL BOX INEXISTING PANEL LOCATION AND EXTEND PANEL FEEDER TO NEW LOCATION. ALBUQUERQUE | AVON | DENVER| FORT COLLINS 303.278.3820 www.bgbuildingworks.com Project No. 8203.02 Copyright 2018 PROJ. NO. DRAWN: CHECKED: DATE: © BG BUILDINGWORKS SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/12/2018 2:38:03 PM C:\Users\eng-cjb\Documents\820302_FourSeasonsVail_mept17_eng-cjb.rvt 1/8" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 09/12/2018 PERMIT UNIT 3101 ELECTRICAL COVER SHEET E3-01 FOUR SEASONS RESORT AT VAIL Approver GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK. 2. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. 3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER - IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. 4. SERVICE SHALL BE MAINTAINED TO EXISTING AREAS DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE PORTABLEGENERATORS, CABLES, OUTLETS, ETC. AS REQUIRED TO MAINTAIN CONTINUITY OF SERVICE. PLACEMENT OF SUCH PORTABLE EQUIPMENT SHALL BE SUBJECT TO OWNER APPROVAL. 5. REVIEW ARCHITECTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID. 6. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 7. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES ANDORDINANCES. 8. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 9. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS. 10. EXISTING SYSTEMS AND CONDITIONS SHOWN ON DRAWINGS FOR EXISTING BUILDINGS ARE TO BE NOTED “FOR GUIDANCE ONLY”.THE ELECTRICAL CONTRACTOR TO FIELD CHECK ALL EXISTING CONDITIONS PRIOR TO BIDDING AND TO INCLUDE IN HIS BID AN ALLOWANCE FOR REMOVAL AND/OR RELOCATION OF EXISTING CONDUITS, WIRES, DEVICES, FIXTURES, OR OTHER EQUIPMENT AS INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL SYSTEM TO ALL OTHERWORK AS REQUIRED 11. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL AND ELECTRICAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. 12. PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED CONDUIT, WIRE, CABLE, J-BOXES, RECEPTACLES, SWITCHES, LIGHTS, FIRE ALARMS DEVICES, ETC. COMPLETE WITH ASSOCIATED CIRCUITING TO SOURCE. WHERE IT IS NOTFEASIBLE TO REMOVE THE ABOVE, OUTLET SHALL BE ABANDONED, WIRE REMOVED, AND BLANK COVER PLATES PROVIDED. 13. ALL (E) EQUIPMENT, LAMPS, BALLASTS, ETC. BEING REMOVED SHALL BE DISCARDED IN ACCORDANCE WITH APPLICABLE EPA REQUIREMENTS. 14. EXISTING LIGHT FIXTURES, ELECTRICAL EQUIPMENT, ETC. BEING REMOVED SHALL BE RETURNED TO THE OWNER, EXCEPT FOR THOSE ITEMS BEING RELOCATED. 15. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN. 16. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION. 17. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED. 18. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 19. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. 20. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 20 AMPERES FOR DUPLEX RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT. 21. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS, UNLESS NOTED OTHERWISE. CONNECTORS SHALL BE INSULATED THROAT TYPE. MINIMUM RACEWAY SIZE IS 3/4”. ALL FEEDERS SHALL BE INSTALLED IN RACEWAY CONFIGURATIONS SHOWN ON ONE-LINE. BRANCH CIRCUITS 25A AND LARGER SHALL BE INSTALLED IN INDIVIDUAL RACEWAYS. BRANCH CIRCUITS 20A AND SMALLER MAY BE GROUPED INTO RACEWAYS AS TO NOT EXCEED 6 CURRENT-CARRYING 75-DEGREE CONDUCTORS, OR 9CURRENT-CARRYING 90-DEGREE CONDUCTORS, IN A SINGLE RACEWAY. METAL CLAD CABLE IS PERMITTED. 22. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUAL, AND SHALL BE IDENTIFIED AT ALL JUNCTION, PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT, ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. 23. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. 24. PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OFPROJECT. 25. PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS. 26. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVED FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT. 27. FIRE ALARM, SOUND, TELEPHONE, COMPUTER AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1” SHALL HAVE LONG RADIUS SWEEPS (12 TIMES THE DIAMETER). 28. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER. 29. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 30. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE. ELECTRICAL SHEET INDEX - PHASE 3 # TITLE ISSUE LOG PERMIT 09.12.18E3-01 UNIT 3101 ELECTRICAL COVER SHEET √ E3-02 ELECTRICAL SPECIFICATIONS √ E3-03 UNIT 3101 DEMO & ELECTRICAL PLANS √ SCALE:NONE1 Electrical One-Line Diagram 10/16/18 ALBUQUERQUE | AVON | DENVER| FORT COLLINS 303.278.3820 www.bgbuildingworks.com Project No. 8203.02 Copyright 2018 PROJ. NO. DRAWN: CHECKED: DATE: © BG BUILDINGWORKS SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/12/2018 2:22:48 PM C:\Users\eng-cjb\Documents\820302_FourSeasonsVail_mept17_eng-cjb.rvt 1/16" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 09/12/2018 PERMIT ELECTRICAL SPECIFICATIONS E3-02 FOUR SEASONS RESORT AT VAIL Approver 10/16/18 REFJ J JJJJJJ J JJ JJ JJ J3.7 4 4.4 5 5.44.2 A10 A11 A12 A13 A9.9 (E)FCU ? (E)FCU ? (E)FCU ? 1 1 1 5 3.7 4 4.4 5 5.4 4.2 A10 A11 A12 A13 A9.9 BEDROOM A3-05 BEDROOM A3-13 BEDROOM A3-23 LIVING ROOM A3-24 BATH 02 A3-26 HALL A3-27 CLOSET A3-25 BATH 01 A3-20 HALL A3-21 CLOSET A3-22 BATH A3-10 HALL A3-11 CLOSET A3-12 HALL 01 A3-01 HALL A3-02 CLOSET A3-04 BATH A3-03 (E)FCU ? (E)FCU ? (E)FCU ? +54" +54" +42" +54" +42" +54" +48" +48" +48" +48" F/S F/S F/S F/S F/S 2 33 3 3 3 2 2 2 +42" 4 4 4 45 5 3 3 1 1 1 1 11 11 11 9 9 9 9 9 35 35 35 35 35 15 15 15 15 1515 15 17 17 7 21 23 25 25 25 25 2525 27 27 31 33 CO CO CO 5 ALBUQUERQUE | AVON | DENVER| FORT COLLINS 303.278.3820 www.bgbuildingworks.com Project No. 8203.02 Copyright 2018 PROJ. NO. DRAWN: CHECKED: DATE: © BG BUILDINGWORKS SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/12/2018 2:22:51 PM C:\Users\eng-cjb\Documents\820302_FourSeasonsVail_mept17_eng-cjb.rvt 1/4" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 09/12/2018 PERMIT UNIT 3101 DEMO & ELECTRICAL PLANS E3-03 FOUR SEASONS RESORT AT VAIL Approver SCALE:1/4" = 1'-0"1 UNIT 3101 ELECTRICAL DEMOLITION PLAN SCALE:1/4" = 1'-0"2 UNIT 3101 ELECTRICAL PLAN NOTES: 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCES, EXCEPT FOR BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH- IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO LIGHTING DESIGN PLANS AND SPECIFICATIONS FOR WORK ASSOCIATED WITH THE LIGHTING AND LIGHTING CONTROL SYSTEM. REFER TO LIGHTING DESIGN PLANS FOR ENERGY CODE COMPLIANCE DOCUMENTATION. REFER TO LIGHTING PLANS FOR SWITCH LOCATIONS FOR SWITCHED RECEPTACLES. 5. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 6. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW-VOLTAGE SYSTEMS PLANS. 7. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. FIRE ALARM SYSTEM SHALL BE DESIGN/BUILD BY CONTRACTOR. DEVICES SHOWN ON PLAN ARE FOR DESIGN INTENT ONLY. NEW FIRE ALARM DEVICES SHALL BE COMPATIBLE AND TIED INTO EXISTING FIRE ALARM SYSTEM. 8. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 9. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 10. CONTRACTOR SHALL PROVIDE "BOX WALK" WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 11. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 12. ALL DEVICES ARE CIRCUITED TO RELOCATED PANEL PP-RC2A. NUMBER NEXT TO DEVICE INDICATES CIRCUIT NUMBER. 1 EXISTING FCU TO REMAIN. 2 PROVIDE 20A, 120V ELECTRICAL FEED TO JUNCTION BOX FOR MIRROR. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER SUBMITTAL PRIOR TO ROUGH-IN. 3 PROVIDE 20A, 120V ELECTRICAL FEED FOR FIRE/SMOKE DAMPER. COORDINATE WITH MECHANICAL DRAWINGS. 4 PROVIDE 20A, 120V ELECTRICAL FEED FOR MOTORIZED DRAPERY. COORDIANTE EXACT LOCATION WITH ARCHITEECT PRIOR TO ROUGH-IN. COORDINATE EXACT POWER WITH MANUFACTURER SUBMITTAL PRIOR TO ROUGH-IN. MOTORIZED DRAPERY SHALL BE CONTROLLED VIA LIGHTING CONTROL SYSTEM. 5 # FLAG NOTES: 10/16/18 UNIT 3101 SHALLS DESIGN STUDIO 1529 EASY RIDER LANE #101 BOULDER, CO 80304 VOICE: 303.596.5235 OWNER MEPARCHITECT CONTRACTOR EX VAIL LLC EXTELL DEVELOPMENT COMPANY 805 THIRD AVENUE NEW YORK, NY 10022 VOICE: 212.712.6000 BG BUILDINGWORKS 1626 COLE BOULEVARD, BUILDING 7-SUITE 300 LAKEWOOD, CO 80401 VOICE: 303.278.3820 OZ ARCHITECTURE 3003 LARIMER STREET DENVER, CO 80205 VOICE: 303.861.5704 THE KORTE COMPANY 12441 U.S. HIGHWAY 40 HIGHLAND, IL 62249 VOICE: 618.654.8611 INTERIOR DESIGN LIGHTING INNOVATIVE LIGHTING CONSULTANTS 720.848.8208 PROJECT LOCATION APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 INTERNATIONAL PLUMBING CODE (IPC) 2012 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2009 ICC/ANSI A117.1 2014 NATIONAL ELECTRICAL CODE (NEC) TOWN OF VAIL LOCAL AMENDMENTS BUILDING OCCUPANCY CLASSIFICATION: R-1 ROOM 3101 OCCUPANCY CLASSIFICATION: R-2 ROOM 3101 EXISTING SF: 2,069 SF HOTEL ROOM 3101A SF: 878 SF HOTEL ROOM 3101B SF: 528 SF HOTEL SUITE 3101C SF: 350 SF OLF: 200 OCCUPANT LOAD PER ROOM: HOTEL ROOM 3101A: 5 HOTEL ROOM 3101B: 3 HOTEL ROOM 3101C: 2 EXISTING UNIT 3101 IS A TYPE "B" OPTION B ACCESSIBLE UNIT - 3101 IS BEING REMODELED INTO (3) NON ACCESSIBLE HOTEL ROOMS. CONSTRUCTION TYPE: TYPE 1-B FIRE RESISTIVE FIRE SUPRESSION: FULLY SPRINKLERED PER NFPA 13 (EXISTING TO REMAIN). KEY PLAN PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:47 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/09/13 PERMIT SUBMITTAL UNIT 3101 COVER G-03 FOUR SEASONS RESORT AT VAIL Approver MATL MATERIAL MAX MAXIMUM MB MOISTURE BARRIER MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEP MECHANICAL, ELECTRICAL and PLUMBING MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE MIN MINIMUM MIRR MIRROR MISC MISCELLANEOUS MM MILLIMETERS MO MASONRY OPENING MTD MOUNT(ED) MTL METAL MUL MULLION (N) NEW N NORTH NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OFF OFFICE OH OPPOSITE HAND OPNG OPENING OPP OPPOSITE OTO OUTSIDE-TO-OUTSIDE P PAINT(ED) P/L PROPERTY LINE PAC PREVIOUSLY AWARDED CONTRACT PAR PARALLEL PBO PROVIDED BY OTHERS PC PRECAST PERF PERFORATED PERIM PERIMETER PKG PARKING PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER PLBG PLUMBING PLYWD PLYWOOD PNL PANEL POL POLISHED PR PAIR or PROPOSAL REQUEST PREFAB PREFABRICATED PREFIN PREFINISHED PRESTR PRESTRESSED PRIM PRIMARY PROJ PROJECT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POST TENSIONED or PORCELAIN TILE PT POINT OF TANGENCY PTD PAPER TOWEL DISPENSER PTDR PAPER TOWEL DISPENSER AND RECEPTACLE PTN PARTITION PTR PAPER TOWEL RECEPTACLE PVC POLYVINYL CHLORIDE PVMT PAVEMENT QT QUARRY TILE QTY QUANTITY (R) REMOVE R RISER RAD RADIUS RB RUBBER BASE RBC RUBBER BASE COVE RBS RUBBER BASE STRAIGHT RBT RUBBER TILE RD ROOF DRAIN or ROAD RE REFER TO or REFERENCE REC RECESS(ED) RECPT RECEPTACLE REF REFRIGERATOR or REFRIGERATED REINF REINFORCED REQD REQUIRED RESIL RESILIENT REV REVISE, REVISED or REVISION(S) RF RESILIENT FLOORING RFG ROOFING RFL REFLECTED RH RIGHT HAND RL RAIN LEADER RM ROOM RO ROUGH OPENING ROD ROOF OVERFLOW DRAIN ROW RIGHT OF WAY RPM REVOLUTIONS PER MINUTE RVS REVERSE (SIDE) RWC RAIN WATER CONDUCTOR S SOUTH or SEALED SC SOLID CORE SCD SEAT COVER DISPENSER SCHED SCHEDULE SD SOAP DISPENSER SEC SECTION SF SQUARE FEET SHT SHEET SHTG SHEATHING SHWR SHOWER SIM SIMILAR SNC SANITARY NAPKIN CABINET SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SOFF SOFFIT SPECS SPECIFICATION(S) SPKL SPRINKLER SPKR SPEAKER SPRT SUPPORT SQ SQUARE SR SINK RECEPTACLE SS STAINLESS STEEL or SOLID SURFACE SSK SERVICE SINK STA STATION STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURE or STRUCTURAL SUSP SUSPEND(ED) SYM SYMMETRICAL SYS SYSTEM T TREAD T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TB TOWEL BAR TBC TOP OF BACK OF CURB TELE TELEPHONE TEMP TEMPORARY or TEMPERATURE TG TEMPERED GLASS THERM THERMOSTAT THK THICK or THICKNESS THLD THRESHOLD TO TOP OF TOC TOP OF CONCRETE TOS TOP OF STEEL TOW TOP OF WALL TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TS TUBE STEEL TV TELEVISION TYP TYPICAL UL UNDERWRITER'S LABORATORY UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE UOS UNLESS OTHERWISE SPECIFIED UR. URINAL USGS U.S. GEOLOGICAL SURVEY V VOLT VAR VARY or VARIES VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VENT VENTILATION VER VERIFY VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VIN VINYL or SHEET VINYL VOL VOLUME VTR VENT THROUGH ROOF VWC VINYL WALL COVERING W WEST or WIDE W.O. WHERE OCCURS W/ WITH W/C WATER CLOSET W/O WITHOUT W/R WATER RESISTANT WC WALL COVERING WD WOOD WDO WINDOW WF. WIDE FLANGE or WOOD FLOORING WGL WIRE GLASS WP WATERPROOF(ING) WPT WORKING POINT WSCT WAINSCOT WT WEIGHT WWF WELDED WIRE FABRIC YD YARD # POUND(S) or NUMBER & AND < ANGLE @ AT A/V AUDIO/VISUAL AB ANCHOR BOLT ABV ABOVE ACOUS ACCOUSTICAL ACT ACCOUSTICAL CEILING TILE AD AREA DRAIN or ACCESS DOOR ADD ADDENDUM ADJ ADJACENT or ADJUSTABLE AFF ABOVE FINISHED FLOOR AGG AGGREGATE AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE ARCH ARCHITECTURAL ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS ASPH ASPHALT AUTO AUTOMATIC AVE AVENUE AVG AVERAGE AWP ACOUSTICAL WALL PANEL B BASE B.O. BY OWNER B.O.F. BY OWNER, FUTURE BD BOARD BIT BITUMINOUS BLDG BUILDING BLKG BLOCKING BM BEAM or BENCH MARK BOT BOTTOM BRG BEARNING BSMT BASEMENT C CAULKING C.L. CENTERLINE CAB CABINET CATV CABLE TELEVISION CCD CONSTRUCTION CHANGE DIRECTIVE CCTV CLOSED CIRCUIT TELEVISION CDOT COLORADO DEPARTMENT OF TRANSPORTATION CEM CEMENTITIOUS CFL COUNTERFLASHING CG CORNER GUARD CIP CAST IN PLACE CIRC CIRCUMFERENCE CJ CONTROL JOINT CK CORK TILE CL COLUMN LINE CLG CEILING CLOS CLOSET CLR CLEAR CM CENTIMETERS CMU CONCRETE MASONRY UNIT CO CHANGE ORDER or CLEANOUT COL COLUMN CONC CONCRETE CONF CONFERENCE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CORR CORRIDOR or CORRUGATED CPT CARPET CT CERAMIC TILE CTR COUNTER CU CUBIC CY CUBIC YARD DAMP DAMPROOFING DBL DOUBLE DEG DEGREE DEMO DEMOLISH or DEMOLITION DEPT DEPARTMENT DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN DR DOOR DS DOWNSPOUT DTL DETAIL DWG DRAWING DWR DRAWER (E) EXISTING E EAST EA EACH EB EXPANSION BOLT ED EXHAUST DUCT EF EXHAUST FAN or EACH FACE EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EMER EMERGENCY ENGR ENGINEER EOS EDGE OF SLAB EQ EQUAL EQUIP EQUIPMENT ES EACH SIDE EST ESTIMATE EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXT EXTERIOR F FARENHEIT FA FIRE ALARM FAC FIRE ALARM CABINET FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHER(S) FD FLOOR DRAIN or FIRE DAMPER FDN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FFL FINISHED FLOOR LINE FH FIRE HYDRANT FHC FIRE HOSE CABINET FHMS FLAT HEAD MACHINE SCREW FHV FIRE HOSE VALVE FHWS FLAT HEAD WOOD SCREW FIN FINISH(ED) FIXT FIXTURE FLG FLASHING FLR FLOOR(ING) FLUOR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUD FR FIRE RESISTIVE or FIRE RATED FRP FIBERGLASS REINFORCED PANEL(ING) FRT FIRE RETARDANT TREATED FT FOOT (FEET) FTG FOOTING FURN FURNISH(ED) FURR FURRED or FURRING FUT FUTURE FVC FIRE VALVE CABINET GA GAUGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GCMU GLAZED CONCRETE MASONRY UNIT(S) GI GALVANIZED IRON GL GLASS or GLAZING GND GROUND GR GRADE GRT GROUT GT GLASS TILE GWB GYPSUM WALLBOARD GYP GYPSUM GYP. BD. GYPSUM BOARD HAS HEADED ANCHOR STUD HB HOSE BIB HC HOLLOW CORE or HANDICAPPED HDAS HEADED DEFORMED ANCHOR STUD HDR HEADER HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HTR HEATER HVAC HEATING, VENTILATION and AIR CONDITIONING HW HOT WATER HWH HOT WATER HEATER HWY HIGHWAY IBC INTERNATIONAL BUILDING CODE or INSTALLED BY CONTRACTOR ID INSIDE DIAMETER IN INCH(ES) INCAND INCANDESCENT INCL INCLUD(ED) INFO INFORMATION INSUL INSULATION or INSULATED INT INTERIOR INTMED INTERMEDIATE INV INVERT JC JANITOR CLOSET JST JOIST JT JOINT KD KNOCKDOWN KIT KITCHEN KO KNOCKOUT KP KICK PLATE LAB LABORATORY LAM LAMINATE LAV LAVATORY LBL LABEL LDR LEADER LH LEFT HAND LKR LOCKER LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LP LIGHTING PANEL or LIGHT PROOF LT LIGHT LTL LINTEL LVR LOUVER MACH MACHINERY MAG MAGNETIC MAS MASONRY ABBREVIATIONS GENERAL NOTES GRAPHIC STANDARDS PROJECT TEAM VICINITY MAP FOUR SEASONS RESORT AT VAIL PERMIT SUBMITTAL 2018/09/13 ONE VAIL ROAD VAIL, CO 81657 TRUE NORTH *NOTES - GENERAL PROJECT NOTES 1 THE TERM “GC” SHALL MEAN THE GENERAL CONTRACTOR AND ITS SUB-CONTRACTORS. 2 THE GC SHALL THOROUGHLY FAMILIARIZE ITSELF WITH THE CONTRACT DOCUMENTS AND THE SITE. SHOULD THE GC FIND DISCREPANCIES IN, OR OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS, SHOULD THE GC BE IN DOUBT AS TO THEIR INTENT OR MEANING, OR HAS QUESTIONS CONCERNING CONSTRUCTABILITY OR CODE COMPLIANCE, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. SHOULD A CONFLICT OCCUR BETWEEN THE DRAWINGS AND SPECIFICATIONS THAT IMPLYING GREATER QUANTITY OR QUALITY SHALL PREVAIL. 3 THE INTENT OF THE CONTRACT DOCUMENTS IS TO PROVIDE A COMPLETE PROJECT. EVERY ITEM NECESSARILY REQUIRED MAY NOT BE SPECIFICALLY MENTIONED OR SHOWN. UNLESS EXPRESSLY STATED, SYSTEMS AND EQUIPMENT SHALL BE COMPLETELY OPERATIONAL. PROVIDE INCIDENTAL, ACCESSORY, AND ANY OTHER ITEMS NOT SPECIFIED, BUT REQUIRED, FOR A COMPLETE AND FINISHED ASSEMBLY. 4 THE ENTIRE SET OF CONTRACT DOCUMENTS REPRESENT THE PROJECT AS A WHOLE. THE GC IS RESPONSIBLE FOR PROVIDING SUFFICIENT INFORMATION TO ITS SUB-CONTRACTORS TO DETERMINE AND PERFORM THEIR SCOPE OF WORK. 5 ANY ELECTRONIC CAD AND/OR BUILDING INFORMATION MODELING (BIM) FILES PROVIDED BY THE ARCHITECT OR ITS CONSULTANTS IS SOLELY TO ASSIST THE GC IN PREPARATION OF SHOP DRAWINGS AND/OR LAYOUT OF THE PROJECT. CAD AND BIM FILES ARE NOT A PART OF THE CONTRACT DOCUMENTS AND ANY INFORMATION CONTAINED THEREIN DOES NOT SUPERSEDE ANY INFORMATION ON THE CONTRACT DOCUMENTS. 6THE GC IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION, COORDINATION OF TRADES, AND SCHEDULING OF THE WORK. 7 THE GC SHALL NOT REVISE, SUBSTITUTE, OR CHANGE THE WORK WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. 8 NOT EVERY CONDITION MAY BE DRAWN OR DETAILED. CONDITIONS SIMILAR TO DETAILED CONDITIONS SHALL BE CONSTRUCTED TO THE SAME SIZE AND CHARACTER AS THOSE FOR SIMILAR CONDITIONS. 9 THE GC SHALL FOLLOW THE RECOMMENDATIONS OF THE OWNER’S GEOTECHNICAL CONSULTANT. SHOULD THE GC FIND DISCREPANCIES WITH THE CONTRACT DOCUMENTS, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 10 DO NOT SCALE DRAWINGS. 11PROVIDE NECESSARY BLOCKING IN WALLS, PARTITIONS, AND CEILINGS FOR ITEMS INCLUDING, BUT NOT LIMITED TO: CEILING AND PARTITION-MOUNTED FIXTURES, GRAB BARS, HANDRAILS, TOILET ACCESSORIES, CABINETRY, PANELING, COUNTERTOPS, SHELVES, CLOSET RODS, WHITE BOARDS, AND DECORATIVE ELEMENTS. 12THE CONSTRUCTION DOCUMENTS ARE THE PROPERTY OF OZ ARCHITECTURE, INC. AND ITS CONSULTANTS AND ARE TO BE USED AS INSTRUMENTS OF SERVICE FOR CONSTRUCTION OF THIS PROJECT ONLY. USE OF THESE DOCUMENTS BY THE GC FOR ANY OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN CONSENT OF OZ ARCHITECTURE IS PROHIBITED. Legal Description: Subdivision: Vail Village Filing 2, Lot: A-C Parcel #210107122001 DRAWING INDEX 10/16/18 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:48 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/09/13 PERMIT SUBMITTAL SPECIFICATIONS G-101 FOUR SEASONS RESORT AT VAIL Approver 10/16/18 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:50 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 2018/09/13 PERMIT SUBMITTAL SPECIFICATIONS G-102 FOUR SEASONS RESORT AT VAIL Approver 10/16/18 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:51 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 2018/09/13 PERMIT SUBMITTAL SPECIFICATIONS G-103 FOUR SEASONS RESORT AT VAIL Approver 10/16/18 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:52 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 2018/09/13 PERMIT SUBMITTAL SPECIFICATIONS G-104 FOUR SEASONS RESORT AT VAIL Approver 10/16/18 30" MAX38" MIN6" MAX 48" MIN 6" MAX 6" MAX38" MINGRAB BAR REINFORCEMENT AT TUB (TYPE A & TYPE B) ICC A117.1 -2009 SECTIONS 1003 & 1004 GRAB BAR REINF AT SHOWER (TYPE A & TYPE B) ICC A117.1-2009 SECTIONS 1003 & 1004 SEAT 6"3' - 6"3' - 2"LIGHT SWITCH DOOR LEVER 6'-8" - 8'-0"4' - 0" MAXDOOR & DEVICES (PUBLIC, TYPE A & TYPE B) ICC A117.1 -2009 SECTIONS 703 & 308 TYP WALL OUTLET THERMOSTAT, PHONE, FIRE ALARM PULL STATION, HC DOOR BUTTON OR CARD READER, IF NOT OBSTRUCTED FIRE ALARM SPEAKER/STROBE MIN1' - 3"ROOM SIGN (PUBLIC) ICC A117.1-2009 SECTION 703 OUTLET AT COUNTER- PARALLEL APPROACH (TYPE B) ICC A117.1 -2009 SECTION 308 FIRE EXTINGUISHER CABINET (PUBLIC) ICC A117.1 -2009 SECTION 30846" MAX @ 24" MAX CAB DEPTH48" MAX @ 10" MAX CAB DEPTH4' - 0"3' - 0" MAX4' - 0" MIN5' - 0" MAXTACTILE AREA OF REFUGE SIGN 62" MIN30" MIN6" 8"3' - 8" MIN2' - 8" MAX8" MAX 50" MIN SWING-UP GRAB BAR REINFORCEMENT (TYPE B) ICC A117.1 -2009 SECTION 1004 2' - 5" 9"9" MIN 9" MIN 38" MAX MAXIMUM REACH DEPTH 0.5 INCH 2 INCHES 5 INCHES 6 INCHES 9 INCHES 11 INCHES (13 MM) (51MM) (125MM) (150 MM) (230MM) (288 MM) MAXIMUM REACH HEIGHT 48 INCHES 46 INCHES 42 INCHES 40 INCHES 36 INCHES 34 INCHES (1220 MM) (1170 MM) (1065 MM) (1015 MM) (915 MM) (865 MM) ICC/ANSI A117.1 -2009 TABLE 603.6 MAXIMUM REACH DEPTH AND HEIGHT 2" MAX 46" MIN*2' - 5" 9"8" MAX 58" MIN GRAB BAR REINFORCEMENT & TISSUE DISPENSER (TYPE B) ICC A117.1 -2009 SECTION 1004 HAND-HELD SHOWER UNIT W/ 59" MIN HOSE (TYPE A ONLY)48" MAXT.O. SEAT15" - 19"T.O. SEAT15" - 19"16" - 18"18" MIN18" MIN31" MAX18" MIN31" MAX33" MIN 18" MIN 35" MIN 48" MAX38" MINGENERAL NOTES LAV COUNTER CL 48" MIN CLEARANCE *30" MIN WHERE 46" NOT POSSIBLE HANDLE AT OPEN SIDE CL 24" MIN CONTROL END HAND-HELD SHOWER UNIT W/ 59" MIN HOSE 4" MAX 3" TO 6"18" MIN33" - 36" TO TOPCL CONTROL AREA CL CONTROL AREA CONTROL END 15" MAX CL CONTROL AREA CONTROL WALL HANDLE AT OPEN SIDE 2' - 5" 9"HEAD END 18" MIN 30" MAX38" MINBACK WALL 24" MAX15" MINSEAT WALL COUNTER ALLOWED TO BE 25-1/2" DEEP (MAX) 1. DIMENSIONS ARE COMPLIANT WITH ICC A117.1-2009. 2. NOT ALL FIXTURES AND DEVICES INDICATED MAY BE USED IN THE PROJECT. 3. MOUNTING HEIGHTS INDICATED MAY BE SUPERCEDED BY MORE SPECIFIC INFORMATION ELSEWHERE IN THE DOCUMENTS. 4. "PUBLIC" INDICATES ELEMENTS TO COMPLY IN PUBLIC AREAS. "TYPE A" INDICATES ELEMENTS TO COMPLY IN ACCESIBLE PORTIONS OF TYPE A UNITS. "TYPE B" INDICATES ELEMENTS TO COMPLY IN ACCESSIBLE PORTIONS OF TYPE B UNITS. 5. PROVIDE BLOCKING / REINFORCEMENT FOR ALL ACCESSORIES PER MANUFACTURER'S INSTRUCTIONS. 6. PROVIDE BLOCKING / REINFORCEMENT FOR FUTURE INSTALLATION OF GRAB BARS IN ACCESSIBLE BATHROOMS OF "TYPE A" & "TYPE B" UNITS. 7. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS & SHALL WITHSTAND A VERTICAL OR HORIZONTAL FORCE OF 250 LBS APPLIED TO ANY POINT ON THE GRAB BAR, FASTENEER, MOUNT, OR SUPPORT. 8. SHOWER & BATHTUB SEATS SHALL WITHSTAND A VERTICAL OR HORIZONTAL FORCE OF 250 LBS APPLIED TO ANY POINT ON THE SEAT, FASTENER, MOUNT OR SUPPORT. 9. ALL APPLIANCES & PLUMBING FIXTURES MUST COMPLY WITH APPLICABLE ANSI & ADA REQUIREMENTS. OPERABLE PARTS SHALL: 1) BE 34" - 48" AFF.; 2) BE OPERABLE WITH ONE HAND, 3) NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST, AND 4) BE ACTIVATED BY NO MORE THAN 5 LBS OF FORCE. 10. DOOR THRESHOLDS MUST HAVE A MAXIMUM HEIGHT OF 1/2" WITH A 1:2 BEVEL. 9" MIN9" MIN 48" MIN TO B.O. LOWEST TEXT60" MAX TO B.O. HIGHEST TEXTROOM NAME PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:53 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvt 1/2" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/09/13 PERMIT SUBMITTAL STANDARD MOUNTING HEIGHTS - ANSI 2009 G-401 FOUR SEASONS RESORT AT VAIL Approver 10/16/18 1 1/4"MIN. AT 1:2 2 1/2" MIN. 1 1/2"3/4"1/2"NOTE: 1 1/4" HEIGHT IS DIFFICULT FOR WHEELCHAIR USERS EXTERIOR SIDE THRESHOLDS AT EXTERIOR DOORS ACCEPTABLE 3/4"MIN. 1 1/2"1/4"1/2"NOTE: 1 1/4" HEIGHT IS DIFFICULT FOR WHEELCHAIR USERS EXTERIOR SIDE THRESHOLDS AT EXTERIOR DOORS ACCEPTABLE THRESHOLDS AT EXTERIOR DOORS GOOD MAX. 3/4"MIN. 1 1/2" NOTE: INTERLOCKING THRESHOLD MAXIMUM HEIGHT DIFFERENCE BETWEEN INTERIOR FLOOR LEVEL AND EXTERIOR FLOOR LEVEL LEVEL DIFFERENCE AT PRIMARY ENTRANCE DOORPERVIOUS CONSTRUCTION (WOOD DECKING) IMPERVIOUS CONSTRUCTION (CONCRETE, BRICK) 0" 1/2" LEVEL DIFFERENCE AT SECONDARY ENTRANCE DOOR PERVIOUS CONSTRUCTION IMPERVIOUS CONSTRUCTION 1/2" 4" FAIR HOUSING ACT DESIGN MANUAL PG. 4.112' - 6"2' - 6"30" X 48" CLEAR FLOOR SPACE WHEELCHAIR CLEAR FLOOR AREA 5' - 0"MIN.3' - 0"MIN.5' - 0"WALLS WHEELCHAIR T-TURN FLOOR AREA ACCESSIBLE DOOR 1' - 6" 1' - 3" MIN. 2' - 9"MIN. 5' - 8"MIN.5' - 6"MINIMUM FHA REQUIREMENTS FOR POWDER ROOM DOOR, SWITCHES & OUTLETS MAX. FORWARD REACH OVER AN OBSTRUCTION W/ CLEAR KNEESPACE MAX. FORWARD REACH OVER AN OBSTRUCTION W/ CLEAR KNEESPACE MAX. SIDE REACH OVER AN OBSTRUCTION W/ NO KNEESPACE MAX. SIDE REACH STACKED WASHER DRYER UNIT MINIMUM FHA REQUIREMENTS FOR "B" BATHROOM (ANSI TYPE B OPTION B) MINIMUM FHA REQUIREMENTS FOR U-SHAPED KITCHENS MINIMUM FHA REQUIREMENTS CLEAR FLOOR SPACE AT COOKTOPS/STOVES MINIMUM FHA REQUIREMENTS CLEAR FLOOR SPACE AT SINKS MINIMUM FHA REQUIREMENTS CLEAR FLOOR SPACE AT REFRIGERATORS MINIMUM FHA REQUIREMENTS FOR U-SHAPED KITCHENS EXCEPTION MINIMUM FHA REQUIREMENTS FOR GALLEY KITCHENS MINIMUM FHA REQUIREMENTS FOR GALLEY KITCHENS 34" MAXIMUM COUNTERTOP HEIGHT. 27" CLEAR KNEE SPACE. PG. 7.52 REMOVABLE BASE CABINET TO ALLOW FOR PARALLEL APPROACH TO LAVATORY PG 7.38 30" X 48" CLEAR FLOOR SPACE FOR PERPENDICULAR APPROACH TO SINK REQ. BY FHA 48" X 66" CLEAR FLOOR SPACE AT TOILET REQ. 7 GRAB BAR REINFORCING IN WALL. ADDITIONAL 2" ON EITHER SIDE AND BOTTOM OF GRAB BAR RECOMMENDED FOR MOUNTING. PG 6.3 20" - 25" MAX.3' - 8"MIN. KNEE SPACE2' - 3"MAX.3' - 10"MAX.3' - 0"MAX. 2' - 0"0" - 20" MAX.4' - 0"MIN. KNEE SPACE2' - 3"USER IN PERPENDICULAR POSITION TO CABINET USER IN PERPENDICULAR POSITION TO CABINET USER IN PARALLEL POSITION TO CABINET USER IN PARALLEL POSITION TO CABINETMAX.4' - 6"CABINET BELOW FAN / LIGHT SWITCH, THERMOSTAT FAN / LIGHT SWITCH, THERMOSTAT FAN / LIGHT SWITCH, THERMOSTAT FAN / LIGHT SWITCH, THERMOSTAT WALL OUTLET MIN.1' - 3"MAX.4' - 0"MIN.6' - 8"MIN. 2' - 10" CABINET BELOW OPEN BELOW OPEN BELOW DRYER TOP LOADING WASHER 30" X 48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH CENTERED ON STOVE STOVE WITH RETRACTABLE DOORS AND CLEAR KNEE SPACE BELOW 30" X 48" CLEAR FLOOR SPACE FOR PERPENDICULAR APPROACH WITH MAXIMUM OF 19" OF FLOOR SPACE EXTENDING UNDER STOVE 30" X 48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH CENTERED ON STOVE 30" X 48" CLEAR FLOOR SPACE FOR PERPENDICULAR APPROACH WITH MAXIMUM OF 19" OF FLOOR SPACE EXTENDING UNDER STOVE MIN.2' - 6"SINK WITH REMOVABLE BASE CABINET AND CLEAR KNEE SPACE BELOW 34" MAX. SINK / COUNTERTOP HEIGHT WITH PERPENDICULAR APPROACH 36" HIGH COUNTERTOP. 34" RECOMMENDED FOR ACCESSIBLE UNITS. 30" X 48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH FROM FAR SIDE OF DOOR FOR PARALLEL APPROACH DOOR SWING OF 180 DEGREES IS PREFERRED 30" X 48" CLEAR FLOOR SPACE FOR FORWARD APPROACH REF. REF. 30" X 48" CLEAR FLOOR SPACE OUTSIDE SWING OF DOOR REQUIRED. DOUBLES AS ACCESS TO BATHTUB AND TOILET 48" X 66" CLEAR FLOOR SPACE AT TOILET REQ. 7 GRAB BAR REINFORCING IN WALL. ADDITIONAL 2" ON EITHER SIDE AND BOTTOM OF GRAB BAR RECOMMENDED FOR MOUNTING. PG 6.3 1' - 6" 6' - 10"7' - 9" FIXED BASE CABINET ACCEPTABLE SINCE PARALLEL APPROACH IS POSSIBLE PG. 7.36 30" X 48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH TO SINK REQ. BY FHA MIN. 3' - 0"MIN.3' - 4"MIN. 3' - 0" 30" X 48" CLEAR FLOOR SPACE FOR FORWARD APPROACH TO REFRIGERATOR MAX. SINK HEIGHT OF 34" WITH PERPENDICULAR APPROACHSINK WITH REMOVABLE BASE CABINET AND KNEE SPACE BELOW STOVE WITH RETRACTABLE DOORS AND CLEAR KNEE SPACE BELOW 30" X 48" CLEAR FLOOR SPACE FOR PERPENDICULAR APPROACH WITH MAXIMUM OF 19" OF FLOOR SPACE EXTENDING UNDER STOVE 30" X 48" CLEAR FLOOR SPACE FOR PERPENDICULAR APPROACH WITH MAXIMUM OF 19" OF FLOOR SPACE EXTENDING UNDER SINK 36" HIGH COUNTERTOP. 34" RECOMMENDED FOR ACCESSIBLE UNITS. NOTE: WHEELCHAIR USER CANNOT TURN AROUND IN THIS KITCHEN LAYOUT 30" X 48" CLEAR FLOOR SPACE FOR FORWARD APPROACH TO REFRIGERATOR 30" X 48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH CENTERED ON STOVE 30" X 48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH CENTERED ON SINK ALLOWS FOR FORWARD APPROACH TO DISHWASHER 36" HIGH COUNTERTOP. 34" RECOMMENDED FOR ACCESSIBLE UNITS. NOTE: WHEELCHAIR USER CANNOT TURN AROUND IN THIS KITCHEN LAYOUT MAX. SINK HEIGHT OF 34" WITH PERPENDICULAR APPROACH. SINK WITH REMOVABLE BASE CABINET AND KNEE SPACE BELOW STOVE WITH RETRACTABLE DOORS AND CLEAR KNEE SPACE BELOW 30" X 48" CLEAR FLOOR SPACE FOR PERPENDICULAR APPROACH WITH MAXIMUM OF 19" OF FLOOR SPACE EXTENDING UNDER STOVE 30" X 48" CLEAR FLOOR SPACE FOR PERPENDICULAR APPROACH WITH MAXIMUM OF 19" OF FLOOR SPACE EXTENDING UNDER SINK 36" HIGH COUNTERTOP. 34" RECOMMENDED FOR ACCESSIBLE UNITS. 30" X 48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH CENTERED ON REFRIGERATOR MIN.5' - 0"30" X 48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH CENTERED ON STOVE 30" X 48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH CENTERED ON REFRIGERATOR 30" X 48" CLEAR FLOOR SPACE FOR PARALLEL APPROACH CENTERED ON SINK 36" HIGH COUNTERTOP. 34" RECOMMENDED FOR ACCESSIBLE UNITS.MIN.2' - 6"2' - 6" REF.REF. REF. REF. DW DW 1' - 3"1' - 3" 2' - 6"PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:55 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/09/13 PERMIT SUBMITTAL FHA INFORMATION G-402 FOUR SEASONS RESORT AT VAIL Approver 1/2" = 1'-0" 2 FHA INFO 10/16/18 PARTITION TYPE - FIRST POSITION INDICATES GENERAL PARTITION TYPE, SECOND POSITION INDICATES RELATIVE WIDTH OF PARTITION. PARTITION TYPES - LEGEND 1. REFERENCE LEGEND, RE: FLOOR PLANS 23C 23C PARTITION DOUBLE DIAMOND INDICATES ACOUSTICAL PARTITION - IDENTICAL TO DESIGNATED PARTITION TYPE EXCEPT WITH ACOUSTICAL BATT INSULATION AND ACOUSTICAL SEALANT AT PERIMETER AND PENETRATIONS. LETTER INDICATES CONDITION AT HEAD OF PARTITION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. NOT ALL PARTITION TYPES DELINEATED MAY BE USED. SEE FLOOR PLANS (A-100 SERIES SHEETS) FOR DESIGNATION OF PARTITION TYPES. SEE CODE PLANS (G-100 SERIES SHEETS) FOR FIRE RATINGS OF PARTITIONS. PARTITIONS ARE TO EXTEND TO UNDERSIDE OF STRUCTURE, UNO. WHERE TWO DIFFERING PARTITION TYPES ABUT IN A LINE AND ALONG A CONTINUOUS LENGTH OF PARTITIONS, THE CONTINUOUS FINISHED SURFACES OF THESE PARTITIONS SHALL ALIGN, UNO. STUD SPACING TO BE 24" O.C. UNO. SEE STRUCTURAL FOR BEARING WALL REQUIREMENTS. PROVIDE PARTITIONS TO MEET MAXIMUM ALLOWABLE DEFLECTION OF L/240 WITH 5 P.S.F. LATERAL LOAD. MAXIMUM ALLOWABLE DEFLECTION FOR PARTITIONS TO RECEIVE TILE SHALL BE L/360. MAXIMUM ALLOWABLE DEFLECTION FOR PARTITIONS TO RECEIVE STONE SHALL BE L/720. ADJUST STUD SPACING, GAGE OR GRADE AS REQ’D. PROVIDE FOR 1" DEFLECTION AT ALL PARTITION HEADS, UNO. AT METAL STUD FRAMED WALLS PROVIDE MINIMUM 3" DEEP-LEG TRACKS. WOOD-FRAMED PARTITON HEADS ARE CONDITION "C" OR "G" UNO. PROVIDE DOUBLE 20 GAGE STUD AT EACH DOOR JAMB IN METAL STUD PARTITIONS. PROVIDE DOUBLE WOOD STUDS AT EACH DOOR JAMB IN WOOD-FRAMED PARTITIONS. DO NOT PLACE GYPSUM BOARD JOINT AT CORNER OF DOOR FRAME. USE 5/8" TYPE-X GYPSUM BOARD AT FIRE-RATED PARTITIONS UNO OR CALLED FOR BY LISTED ASSEMBLY. USE 5/8" GYPSUM BOARD AT ALL OTHER LOCATIONS UNO. USE WATER-RESISTANT GYPSUM BOARD FOR PARTITIONS IN TOILET ROOMS AND JANITOR'S CLOSETS. USE WATER-RESISTANT GLASS-MAT GYPSUM BOARD FOR CEILINGS IN SHOWER ROOMS. COMPLY WITH IBC CHAPTER 25. USE WATER-RESISTANT GLASS-MAT GYPSUM BOARD OR CEMENTITIOUS BACKER UNITS AND SPACE STUDS AT 16” O.C. AT PARTITIONS TO RECEIVE TILE OR STONE. PARTITIONS THAT DO NOT GO TO STRUCTURE ABOVE SHALL HAVE INTERSECTING PARTITION OR BE BRACED TO STRUCTURE @ 12' O.C. PROVIDE CONTROL JOINTS IN CEILINGS EXCEEDING 2500 S.F. AND IN PARTITIONS AND FURRING RUNS EXCEEDING 30 FT. IN LENGTH. VERIFY EXACT LOCATIONS WITH ARCHITECT. SEE DETAILS THIS SHEET. FIRE-RESISTIVE PARTITIONS SHALL BE CONSTRUCTED IN FULL COMPLIANCE WITH TESTING REQUIREMENTS AND MANUFACTURER'S RECOMMENDATIONS FOR CONDITIONS AS REQUIRED. CONSTRUCTION OF ALL SYSTEMS SHALL EQUAL THAT OF THE TESTED ASSEMBLY. GC MAY SUBSTITUTE ANOTHER LISTED ASSEMBLY FOR THAT INDICATED WITH PRIOR APPROVAL OF THE AUTHORITY HAVING JURISDICTION AND THE ARCHITECT. TESTING FACILITIES ARE ABBREVIATED AS FOLLOWS: FM - FACTORY MUTUAL GA - GYPSUM ASSOCIATION NER - NATIONAL EVALUATION REPORT UL - UNDERWRITERS LABORATORIES INC. WHI- WARNOCK HERSEY INTERNATIONAL THROUGH-PENETRATIONS AND MEMBRANE-PENETRATIONS IN FIRE- RATED PARTITIONS SHALL BE FIRESTOPPED IN ACCORDANCE WITH IBC CHAPTER 7. PROVIDE ACOUSTICAL SEALANT AT ALL PENETRATIONS IN ACOUSTICAL PARTITIONS. ACOUSTICAL BATT INSULATION TO TERMINATE AT THE STRUCTURE UNO. CONCEALED SPACES IN COMBUSTIBLE CONSTRUCTION TO BE FIRE- BLOCKED IN ACCORDANCE WITH IBC CHAPTER 7. PARTITION TYPES GENERAL NOTES PARTITION HEAD TO STRUCTURE UL HW-D-0540 FOR 1-HOUR & 2-HOUR RATING - - C CONCRETE DECK CONCRETE DECK PARTITION HEAD TO STRUCTUREPARTITION HEAD TO SUSP CLG- - F - - E METAL STUD, NOT ATTACHED TO CEILING TRACKGYP BD DRYWALL SCREW ACOUS SEALANT3" DEEP-LEG TRACK 6" (NTS) 1" 1 1/2"@ NON-RATED PARTITION @ SUSPENDED CEILING @ RATED PARTITION 1/2" GAPMETAL CONTROL JT GYP BD CONTROL JOINT DETAILS: 1/2" GAP METAL CONTROL JT METAL STUDS SHAFT SIDE ACOUS SHAFTWALL - STC 45-496 - - SEE BELOW FOR STUD SIZE STC PER GA WP-7076 BACKER ROD & SEALANT "J" RUNNER CHANNEL METAL "C-H" STUD ACOUSTICAL INSULATION 1" GYP BD SHAFTWALL LINER PANEL ACOUSTIC PARTITION - STC 45-49 2 - - SEE BELOW FOR STUD SIZE STC PER GA WP-1072 PARTITION - STC 35-39 WITH 1-5/8" STUD - PARTITION WIDTH = 2- 7/8" 26 - 22 - 21 - 23 - WITH 2-1/2" STUD - PARTITION WIDTH = 3- 3/4" WITH 3-5/8" STUD = PARTITION WIDTH = 4- 7/8" WITH 6" STUD - PARTITION WIDTH = 7 1/4" PARTITION PARTITION PARTITION BATT INSULATION & SEALANT ON GYP BD STRIPS 1/2" GAP CENTERED METAL CONTROL JTMETAL STUDS GYP BD (NO. OF LAYERS PER PARTITION TYPE) SHAFT SIDE SHAFTWALL SHAFTWALL SHAFTWALL 62 - 64 - 66 - 2 LAYERS GYP BD HORIZ BRACING, 2 1/2" MTL STUDS @ 4'-0" O.C. VERT ACOUSTICAL INSULATION 2 1/2" METAL STUDS GYP BD RUNNER CHANNEL CLR CHASE WIDTH RE: PLAN FOR ACOUS SEALANT, TYP EACH SIDE FLOOR LINE PLUMBING CHASE PARTITION WIDTH = 6 1/4" + CLEAR CHASE WIDTH 72 - ACOUSTIC FURRING PARTITION1 - - SEE BELOW FOR STUD SIZE FURRING PARTITION WITH 7/8" FURRING CHANNEL - PARTITION WIDTH = 1 1/2" 13 - 11 - 10 - 12 - WITH 1 5/8" STUD - PARTITION WIDTH = 2 1/4" WITH 2 1/2" STUD - PARTITION WIDTH = 3 1/8" FURRING PARTITION FURRING PARTITION FURRING PARTITION FURRING PARTITION16 - LINE OF WALL SURFACE, W.O. GYP BD ACOUSTICAL INSULATION METAL STUD RUNNER CHANNEL SEALANT LINE OF WALL SURFACE, W.O. GYP BD METAL STUD RUNNER CHANNEL SEALANT GYP BD METAL STUD RUNNER CHANNEL SEALANT, EACH SIDE WITH 2 1/2" C-H STUD - PARTITION WIDTH = 3 3/4" WITH 4" C-H STUD - PARTITION WIDTH = 5 1/4" WITH 6" C-H STUD - PARTITION WIDTH = 7 1/4" BACKER ROD & SEALANT "J" RUNNER CHANNEL METAL "C-H" STUD 1" GYP BD SHAFTWALL LINER PANEL 2 LAYERS GYP BD GA SRS-1101 FOR 1-HR RATING & GA SRS-1201 FOR 2-HR RATING GYP BD ACOUSTICAL INSULATION METAL STUD RUNNER CHANNEL SEALANT, EACH SIDE WITH 3-5/8" STUD - PARTITION WIDTH = 4 1/4" WITH 6" STUD - PARTITION WIDTH = 6 5/8"1/2"RE: PLAN 1/2"1/2"1/2" RE: PLAN 1/2"1/2"5/8" 1-5/8" TYPE S DRYWALL SCREWS @ 24" O.C. 2 LAYERS 5/8" TYPE 'X' GYP BD STRIPS FASTENED TO STUDS FLOOR LINE GA WP-1340 FOR 1-HOUR RATING WHERE OCCURS FLOOR LINE FLOOR LINE GA WP-1340 FOR 1-HOUR RATING WHERE OCCURS FLOOR LINE FLOOR LINE UL U415 FOR 2-HOUR RATING WHERE OCCURS1/2"FLOOR LINE UL U415 FOR 2-HOUR RATING WHERE OCCURS GYP BD (NO. OF LAYERS PER PARTITION TYPE) 3" DEEP-LEG TRACK MINERAL WOOL FORMING MAT'L & FIRESTOP SPRAY (ACOUSTICAL SEALANT @ NON-RATED PARTITIONS) DRYWALL SCREW GYP BD (NUMBER OF LAYERS PER PARTITION TYPE)1 1/2"1" L-BEAD, TYP EA SIDE FOAM GASKET RUNNER CHANNEL ATTACHED TO CEILING GRID GYP BD METAL STUD SUSPENDED CEILING 1"SUSP CLG, W.O., RE: CEILING PLAN SUSP CLG, W.O., RE: CEILING PLAN ACOUSTIC PARTITION - STC 50-544 - - SEE BELOW FOR STUD SIZE 2 LAYERS GYP BD EA. SIDE METAL STUD RUNNER CHANNEL 1/2"ACOUSTICAL INSULATION BACKER ROD & SEALANT, EACH SIDE FLOOR LINE GA WP-1530 FOR 2-HOUR RATING WHERE OCCURS CEMENT MORTAR JOINTS WALL MEMBRANE 5/8" GYP SHEATHING MORTAR SETTING BED STONE ANCHOR TYP. 5" 1" 6" STEEL STUDS (MIN) @ 12" O.C. (MAX) WHERE OCCURS, PER PLAN INTERIOR FINISH, WHERE OCCURS, S.I.D. +/- 2.75" SPRAY APPLIED POLYURETHANE FOAM INSULATION TO ACHIEVE R-19 THERMAL BARRIER FOR INSULATION INFILLED EXTERIOR WALL ASSEMBLY E1 AT UNIT 3101 ONLY PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:56 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvtAs indicatedFOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 OZ OZ 2018/09/13 PERMIT SUBMITTAL PARTITION TYPES, VERTICAL & HORIZONTAL ASSEMBLIES G-503 FOUR SEASONS RESORT AT VAIL Approver 10/16/18 RE: PLAN FOR PARTITION TYPE HM FRAME, RE: DOOR SCHEDULE DOUBLE METAL STUD HEADER FOR DIMENSION RE: PARTITION TYPE 2"SEALANT EA. SIDE 1/2"PTN WIDTH +1" 1/2". 1/2" DOOR, RE: DOOR SCHEDULE WOOD TRIM, S.I.D. RE: PLAN FOR PARTITION TYPE DOOR, RE: DOOR SCHEDULE HM FRAME, RE: DOOR SCHEDULE DBL. METAL STUD JAMB FOR DIMENSIONRE: PARTITION TYPE2" SEALANT EA SIDE PTN WIDTH +1"1/2"1/2". 1/2"WOOD TRIM, S.I.D. HM DOOR FRAME RE: DOOR SCHEDULE HM DOOR RE: DOOR SCHEDULE FOR DOOR TYPE AND FINISH SET THRESHOLD IN (2) CONTINUOUS LINES SEALANT CONCRETE SLAB, RE: STRUCTURAL FLOOR FINISH RE: ROOM FINISH SCHEDULE DOOR THRESHOLD RE: DOOR SCHEDULE PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/13/2018 2:18:57 PM C:\Revit Local Files\116194.00_Four Seasons Vail_A17_Central_OZ_User.rvt 3" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 2018/09/13 PERMIT SUBMITTAL ARCHITECTURAL DETAILS G-504 FOUR SEASONS RESORT AT VAIL Approver 3" = 1'-0" 1 DOOR - HM - HEAD - MTL STUD 3" = 1'-0"2 DOOR - HM - JAMB - MTL STUD 3" = 1'-0"3 DOOR - HM - THRESHOLD @ INTERIOR 10/16/18 LUMINAIRE SCHEDULE TYPE DESCRIPTION MANUFACTURER CATALOG # FINISH CCT WATTAGE VOLTAGE DIM NOTES C1 CEILING MOUNT, CLOSET 120 120 LED RETROFIT LAMP, SPECIFICATION TBD BY ILC. C2 CEILING MOUNT DECORATIVE 30 120 EXACT INSTALLATION LOCATION PER ID. C3 CEILING MOUNT DECORATIVE 120 120 EXACT INSTALLATION LOCATION PER ID. C4 CEILING MOUNT DECORATIVE 120 120 EXACT INSTALLATION LOCATION PER ID. C5 CEILING MOUNT DECORATIVE 120 120 EXACT INSTALLATION LOCATION PER ID. D1 RECESSED DOWNLIGHT, ADJUSTABLE 3000 20 120 ELV FLANGE DEPTH- TBD L1 LED STRIP, CUSTOM UPLIGHT DETAIL 2700 7.3W/FT 120 MLV REMOTE DRIVER. CUSTOM MUD-IN DETAIL. REFER TO DETAIL 2 ON SHEET LP1-03 L2 LED STRIP, SLOT DETAIL 2700 7.3W/FT 120 MLV REMOTE DRIVER. REFER TO DETAIL 3 ON SHEET LP1-03 L3 LED STRIP, COVE DETAIL 2700 4.4W/FT 120 MLV REMOTE DRIVER. DETAIL TBD L5 LED STRIP, UPPERCABINET 2700 4.4W/FT 120 MLV REMOTE DRIVER. DETAIL TBD L6 LED STRIP, HORIZONTAL SHELF 2700 4.0W/FT 120 MLV REMOTE DRIVER. DETAIL TBD L7 LED STRIP, VERTICAL SHELF 2700 4.0W/FT 120 MLV REMOTE DRIVER. DETAIL TBD L8 LED STRIP, SHOWER SHELF 2700 2.0W/FT 120 MLV REMOTE DRIVER. DETAIL TBD L9 LED STRIP, FIREPLACE COVE 2700 7.3W/FT 120 MLV REMOTE DRIVER. REFER TO DETAIL 3 ON SHEET LP1-03 L10 LED STRIP, RECESSED AT CLOSETS 2700 4.0W/FT 120 MLV REMOTE DRIVER. DETAIL TBD L11 LED STRIP, COVE DETAIL 2700 4.0W/FT 120 MLV REMOTE DRIVER. DETAIL TBD L17 LED STRIP, BACKLIT MIRROR 2700 4.4W/FT 120 MLV REMOTE DRIVER. CUSTOM MUD-IN DETAIL. REFER TO DETAIL 4,5,6 ON SHEET LP1-03 L18 LED STRIP, HEADBOARD DETAIL 2700 7.3W/FT 120 MLV REMOTE DRIVER. DETAIL TBD. P2 POWDER VANITY MINI PENDANTS 6 120 EXACT INSTALLATION LOCATION AND DROP HEIGHT PER ID. P6 MASTER VANITY PENDANTS 60 120 EXACT INSTALLATION LOCATION AND DROP HEIGHT PER ID. S1 2' CLOSET LED LINEAR FIXTURE 3000 20 120 N/A CONTROL VIA CEILING MOUNTED OCCUPANCY SENSOR S2 3' CLOSET LED LINEAR FIXTURE 3000 20 120 N/A CONTROL VIA CEILING MOUNTED OCCUPANCY SENSOR W1 ILLUMINATED MIRROR 60 W3 DECORATIVE WALL SCONCE 60 120 EXACT INSTALLATION LOCATION PER ID. W4 WALL MOUNTED ART LIGHT, 60 INCH 3000 60 120 0-10 EXACT INSTALLATION LOCATION PER ID. REFER TO DETAILED BOM AND INSTALLATION INSTRUCTIONS BY MANUFACTURER. W8 WALL MOUNTED SWIVEL ARM MIRROR 15 120 N/A EXACT INSTALLATION LOCATION PER ID. ELECTRICAL CONTRACTOR BID NOTES: PER DIRECTION OF OWNER, INNOVATIVE LIGHTING CONSULTANTS (ILC) SHALL BE THE SOLE DISTRIBUTOR OF ALL LIGHTING FIXTURES, LIGHTING EQUIPMENT, LIGHTING CONTROL AND EM DEVICES, UNLESS SPECIFICALLY EXCLUDED FROM ILC SCOPE IN WRITING. ELECTRICAL CONTRACTOR SHALL PURCHASE ALL SAID MATERIALS FROM ILC FOR THE DURATION OF CONSTRUCTION. PER INDUSTRY STANDARD, ELECTRICAL CONTRACTOR BID SHALL INCLUDE APPLICABLE MARKUP APPLIED TO ILC SUPPLIED FIXTURE PACKAGE. ELECTRICAL CONTRACTOR TO PROVIDE BID FOR LABOR AND INSTALLATION MATERIALS. ALTERNATE FIXTURE PACKAGES WILL NOT BE CONSIDERED. LUMINAIRE SCHEDULE NOTES: FIXTURE SUBSTITUTION REQUESTS MUST BE SUBMITTED IN WRITING TO ILC FOR CONSIDERATION AND SHALL REQUIRE WRITTEN APPROVAL BY ILC AND THE ARCHITECT. NOTE: UPPER-CASE LETTER OF LUMINAIRE TAG INDICATES LUMINAIRE TYPE. LOWER-CASE LETTER OF LUMINAIRE TAG INDICATES SWITCHING ZONE. SYMBOL DESCRIPTION RECESSED DOWNLIGHT RECESSED WALL WASHER / ADJUSTABLE STEM / SURFACE MOUNTED CYLINDER PENDANT LUMINAIRE SURFACE LUMINAIRE WALL SCONCE WALL MOUNTED LINEAR LUMINAIRE PENDANT MOUNTED LINEAR LUMINAIRE RECESSED TROFFER ARCHITECTURAL LINEAR LUMINAIRE ARCHITECTURAL LINEAR WALL WASH LUMINAIRE SURFACE OR SUSPENDED STRIP LUMINAIRE WALL RECESSED STEPLIGHT LINEAR LED TAPE INGRADE UPLIGHT / ILLUMINATED PAVER AREA / PEDESTRIAN POLE LUMINAIRE RECESSED MULTIPLE TRACK SYSTEM / MONOPOINT CEILING FAN SURFACE PUCK LUMINAIRE BOLLARD HIGH BAY / GARAGE LUMINAIRE FLOOD / ACCENT LUMINAIRE P OS DESCRIPTION JUNCTION BOX CEILING MOUNT OCCUPANCY SENSOR PHOTOCELL SENSOR SWITCHED WALL MOUNT OCCUPANCY SENSOR SINGLE POLE SWITCH, RELAY CIRCUIT THREE-WAY SWITCH DIMMING SWITCHES LUTRON MYROOM TOUCHSCREEN KEYPAD J SYMBOL a 3 D, M, E, V K REFERENCE TAGS DESCRIPTION SHEET NOTE REFERENCE SYMBOL ABBREVIATIONS ABOVE COUNTER ABOVE FINISHED FLOOR ABOVE FINISHED GRADE DEMOLISH EXISTING TO REMAIN EMERGENCY GROUND LIGHTING MAXIMUM MINIMUM NATIONAL ELECTRIC CODE NIGHT LIGHT NOT TO SCALE ON CENTER STANDARD TYPICAL UNLESS OTHERWISE NOTED VOLTS WATTAGE AC AFF AFG (D) (E) E GND LTG MAX MIN NEC NL NTS OC STD TYP UON V W CONTROL DEVICES D D N P C W, V W P, A T, R R, S R S Z L U, R EP M T F S EB H, G EF LUMINAIRE LEGEND OS CONFLICTS OR SUBSTITUTIONS: ·ELECTRICAL AND GENERAL CONTRACTORS ARE TO CONTACT INNOVATIVE LIGHTING CONSULTANTS (ILC) IF ANY CONFLICTS ARISE OUT OF FIXTURES SPECIFIED AND THEIR AVAILABILITY. ·NO SUBSTITUTION FOR SPECIFIED FIXTURES IS PERMITTED WITHOUT PRIOR APPROVAL FROM ILC. ·CONTRACTOR SHALL COORDINATE PLACEMENT OF ALL CEILING MOUNTED OR RECESSED FIXTURES AND DEVICES WITH OTHER DISCIPLINES AND NOTIFY ARCHITECT OF ANY CONFLICTS BETWEEN THE DRAWINGS AND THE INTENDED INSTALLATION PRIOR TO PROCEEDING WITH INSTALLATION. LAMPING: ·CONTRACTOR TO USE ONLY LAMPS AS SPECIFIED BY ILC PER DRAWINGS. ·CONTRACTOR SHALL INSTALL HONEYCOMB LOUVRES, CLEAR LENSES WHERE SPECIFIED. IF NO INDICATION IS MADE, THE LENS PROVIDED BY THE MANUFACTURER SHALL BE LEFT IN PLACE. ·CONTRACTOR USE MAXIMUM WATTAGE IN ALL FIXTURES, INCLUDING DECORATIVE FEATURES. SWITCHES: ·ALL SWITCHES SHOWN TOGETHER ON PLAN SHALL BE GANGED TOGETHER IN A MULTIGANG BOX WITH A SINGLE FACEPLATE. WHERE SHOWN NEXT TO A WALL CORNER, THE CENTER OF THE BOX SHALL BE LOCATED A MINIMUM 3" FROM THE EDGE OF THE WALL FRAMING. ·ALL WALL MOUNTED MANUAL SWITCH DEVICES SHALL BE MOUNTED TO 48” AFF TO TOP OF BOX SUCH THAT THE ENTIRE SWITCH IS BELOW 48” AS PER ADA COMPLIANCE, OR AS PER LOCAL AUTHORITY HAVING JURISDICTION. ·SWITCHBANKS WITHIN A ROOM ARE TO BE LOCATED 6" FROM THE SIDE OF THE DOOR OPPOSITE THE SWING DIRECTION, AND IN COMPLIANCE WITH ADA HEIGHT REQUIREMENTS. SWITCHES SHALL NOT BE LOCATED BEHIND DOORS UNLESS THERE IS NOT OTHER OPTION. SWITCHES ARE SHOWN ON PLAN WITH EXPANDED SPACING BETWEEN SWITCHES FOR SWITCH TAG CLARITY PURPOSES, NOT AS A SIGN FOR THE SWITCH TO BE LOCATED IN THE EXACT LOCATION SHOWN. ELECTRICAL: ·REMOTE TRANSFORMER/DRIVER/POWER SUPPLY SHALL BE LOCATED IN ACCESSIBLE LOCATION. COORDINATE IN FIELD WITH ARCHITECT. PROVIDE ALL CONNECTIORS, CABLES AND MOUNTING CLIPS AS REQUIRED FOR FULLY OPERATIONAL INSTALLATION. ·ELECTRICAL CONTRACTOR SHALL ENSURE THAT ALL NATIONAL AND LOCAL ELECTRICAL CODES ARE FOLLOWED, INCLUDING BUT NOT LIMITED TO CONVENIENCE OUTLET PLACEMENT, WIRE TERMINATIONS, SWITCH LOCATIONS, AND LIGHTING CONTROL CODES. ·CONTRACTOR TO RUN SEPARATE CONDUIT FOR TELEPHONE, LOW VOLTAGE LIGHTING CONTROL, OR A/V CONTROL, WIRE WHERE INDICATED. MAINTAIN AT LEAST 12” SEPARATION BETWEEN ANY PARRALLEL RUNS OF LINE AND LOW VOLTAGE WIRE. ·CONTRACTOR TO RUN #12 WIRE FROM REMOTE TRANSFORMERS TO LOW VOLTAGE FIXTURES. ·MOUNT LOW VOLTAGE STRIP LIGHT IN LENGTHS PER MANUFACTURERS SPECIFICATIONS. ·CONTRACTOR TO USE ONLY DRIVERS SPECIFIED. OUTLETS: ·CONTRACTOR TO VERIFY ALL POWER REQUIREMENTS WITH OWNER PRIOR TO ROUGH-IN. ·CONTRACTOR TO VERIFY COLOR OF ALL WALL AND FLOOR BOX DEVICES WITH OENER PRIOR TO ROUGH-IN. ·CONTRACTOR TO VERIFY EXACT LOCATION AND STYLE OF FLOOR PLUGS WITH OWNER PRIOR TO ROUGH-IN. LIGHTING CONTROLS: ·LIGHTING CONTROL SYSTEM SHALL BE A RELAY BASED SYSTEM WITH TIME CLOCK, PHOTOCELL, SCHEDULING, AND MANUAL OVERRIDE CONTROLS. ALL COMMON SPACE ZONES THAT ARE NOT TIED TO A SWITCH OR OCCUPANCY SENSOR ON PLAN ARE TO BE CONTROLLED VIA TIME CLOCK SETTINGS TO BE DETERMINED BY OWNER PRIOR TO COMMISSIONING, IN COMPLIANCE WITH IECC CODE. ·ELECTRICAL CONTRACTOR SHALL FOLLOW ALL MANUFACTURER GUIDELINES AND SPECIFICATIONS WITHOUT EXCEPTION. ·LIGHTING CONTROL DEVICES AT BEDSIDES TO BE INSTALLLED 39” A.F.F. TO TOP OF BOX. ·MOTION SENSORS SHALL BE WALL MOUNTED WHERE INDICATED ON PLAN BY AN OCCUPANCY SWITCH SYMBOL. CONTROL ZONING: ·CONTROL ZONING IS DESIGNATED ON PLAN BY A SWITCH NUMBER WHICH FOLLOWS EACH LUMINAIRE TAG (EX. D1/2 OR D1/49,50, “D1” IS THE LUMINAIRE TYPE, AND “2” OR "49,50" IS/ARE THE CONTROL ZONE(S)). WHEN TWO ZONES ARE LISTED FOR ONE FIXTURE, THAT FIXTURE IS TO BE TIED TO BOTH ZONES. REFER TO CONTROL ZONE SCHEDULE NOTES FOR ADDITIONAL CIRCUITING INFORMATION. CONTACT ILC IMMEDIATELY WITH ANY QUESTIONS REGARDING CIRCUITING INDICATION. LUMINAIRES: ·ALL LUMINAIRES WITH A TYPE DESIGNATION ON PLAN ENDING IN "EM" ARE TO BE ON AN EMERGENCY CIRCUIT TIED TO THE BACKUP GENERATOR. UL-924 DEVICES TO BE LOCATED PER ZONE AS REQUIRED. ·WHEN INSULATION IS PRESENT AND A NON IC HOUSING IS SPECIFIED, INSULATION MUST BE HELD AWAY FROM TOP AND SIDES OF HOUSING TO PROVIDE A 3" AIR GAP AROUND ENTIRE HOUSING. ·SPRAY FOAM MUST NOT CONTACT ANY RECESSED HOUSING UNLESS SAID HOUSING IS SPECIFICALLY RATED FOR DIRECT CONTACT WITH SPRAY FOAM INSULATION. ·EC MUST INSTALL DOWNLIGHT HOUSINGS IN SUCH A MANNER AS TO ACCOMMODATE LISTED CEILING THICKNESS LIMITATIONS. ·ILC RECOMMENDS PAINTING DOWNLIGHT FLANGES TO MATCH CEILING. WHEN PAINTING IS TO BE DONE, CARE MUST BE TAKEN TO MASK OFF TRIM REFLECTORS/INTERIORS. TRIM AND CEILING MUST BE ALLOWED TO THROUGHLY DRY BEFORE TRIMS ARE INSTALLED. WALL MOUNT FIXURES: ·VERIFY MOUNTING HEIGHTS OF WALL SCONCES WITH OWNER PRIOR TO ROUGH-IN. LEAVE 24” WHIP TO ALL DECORATIVE FIXTURES. ·USE MAXIMUM ALLOWABLE WATTAGE IN ALL DECORATIVE FIXTURES. SEE "LAMPING" SECTION ABOVE. CONSTRUCTION ADMINISTRATION: ·ELECTRICAL CONTRACTOR SHALL HAVE ALL BOX LOCATIONS APPROVED BY ILC AND OWNER IN A ROUGH-IN WALK THROUGH PRIOR TO RUNNING WIRE. LIGHTING CONTROL SYSTEM: ·IN THE EVENT THAT A TOTAL OR PARTIAL LIGHTING CONTROL SYSTEM IS SPECIFIED, THE ELECTRICAL CONTRACTOR (IN CONJUNCTION WITH CONTROLS DEALER, IF NOT THE CONTRACTOR) SHALL BE RESPONSIBLE FOR SCHEDULING THE “START UP” OF THE LIGHTING CONTROL SYSTEM, INCLUDING BUT NOT LIMITED TO: o CONFIRMING THAT ALL EQUIPMENT IS AS SPECIFIED AND LOCATED/ADRESSED CORRECTLY, AS PER PANEL SCHEDULES. o VERIFYING ALL WIRING TERMINATIONS AND LOW VOLTAGE COMMUNICATION. o CHECKING FOR SHORTS. o VERIFYING THAT EACH LOAD IS LANDED AS SPECIFIED PER PANEL SCHEDULES AND IS FUNCTIONING PROPERLY. o VERIFYING THAT EACH KEYPAD AND/OR DIMMER IS COMMUNICATING AND FUNCTIONING PROPERLY. o ILC SHALL SPECIFY AND DESIGN THE LIGHTING CONTROL SYSTEM BUT SHALL NOT PROVIDE ANY EQUIPMENT OR WARRANTY FOR THE SYSTEM. o IT IS NOT CONSIDERED TO BE IN ILC’S SCOPE OF WORK TO TROUBLESHOOT, ISOLATE, OR OTHERWISE DIAGNOSE WIRING OR EQUIPMENT PROBLEMS. TRIM-OUT AND MOVE-IN NOTES ·ILC SHALL SUPPLY A SET OF DRAWINGS THAT WILL DETAIL ALL LAMPING AND LENSING INFORMATION TO BE INSTALLED BY ELECTRICAL CONTRACTOR AT THE TIME OF TRIM-OUT. TEMPORARY LAMPING MAY BE INSTALLED UNTIL THAT TIME. ·ILC WILL REQUEST ASSISTANCE FROM CONTRACTOR DURING FINAL AIMING. THIS WILL INCLUDE TIME FROM ELECTRICIANS AS WELL AS THE USE OF LADDERS TO REACH ALL ADJUSTABLE ACCENT FIXTURES. THIS MAY BE DIVIDED INTO SEPARATE VISITS DEPENDING ON OWNER’S MOVE-IN SCHEDULE. GENERAL NOTES TYPE PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/6/2018 3:11:30 PM C:\Users\ColinInderwish\Documents\Four Seasons Vail_Lighting_Central_ryanLXJBE.rvt 1/8" = 1'-0"FOUR SEASONS VAILOne Vail Rd Vail, CO 81657CI RB 09/07/2018 PERMIT LIGHTING LEGEND AND LUMINAIRE SCHEDULE LP3-01 FOUR SEASONS VAIL RB 10/16/18 K K K K KK K KK KKKK K KK KK K KKKKL2/53 L8/53 L2/12 L8/7 L2/7 L2/29 L8/37 L2/37 L2/36 L2/54 L2/53 2'-2"1'-9"1'-9"EQ EQ1'-9"3'-5"3'-2"2'-1"2'-7" EQ EQEQ EQL6/5 D1/6D1/6 EQ EQ 2'-8"L18/19 D1/18 D1/18 C3/69 2'-9" 1'-9" C2/1 D1/2 D1/15 C1/17 C1/25 D1/27 D1/27 D1/27 1'-9" D1/30 D1/65 D1/65 P2/66 P2/66L8/68 L2/68 D1/56 D1/56 D1/56 D1/56 1'-9"1'-9" 2'-0"2'-0"L3/58 L3/58 L3/58 L3/58 L9/61 L6/28 W3/63 W3/63 D1/52 D1/51 D1/45 C1/39 D1/24 C4/23 D1/24 EQ EQEQ EQ L18/21 EQEQ EQ EQ C5/43 D1/44D1/44 1'-9"L6/62 D1/57 EQ EQ 3'-0" 3'-0"W4/59 D1/57D1/57 L2/14 L3/40 L3/40 L3/40 L3/40 L10/16 L10/16 L10/26 L10/26 L10/38 L10/38 L5/64 L5/64 S2 S1 L11/32 L11/32 L11/32 L11/32 L11/10 L11/10 L11/10 L11/10 L2/3 L1/55 L1/46 2'-4"1'-9" L14/11 P6/9 P6/9 P6/9 W8/8 L14/67 W8/49 L14/50 1'-4" 3'-4" 3'-4" 1'-4"9"P6/47 P6/47 P6/47 9"2'-5"2'-5"9" 9" P6/34 P6/34 P6/34 W8/31 L14/33 L18/41 3'-11" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" L6/5 L6/28 /20 /20 /22 /22 /42 /42 /60 3'-7" 3'-7" 3'-7" 2'-2" 1'-9" 3'-0"1'-6" 1'-9"1'-9" 1'-9"1'-9"2'-10" 2'-10"3'-6" 3'-6" 2'-1"2'-1" EQ EQ 3'-6" EQEQ 2'-8"2'-8"2'-8"1'-8"1'-8" 1'-6"1'-9"1'-9" 3'-3" EQ EQ EQ EQ PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/6/2018 3:11:31 PM C:\Users\ColinInderwish\Documents\Four Seasons Vail_Lighting_Central_ryanLXJBE.rvt 1/4" = 1'-0"FOUR SEASONS VAILOne Vail Rd Vail, CO 81657CI RB 09/07/2018 PERMIT UNIT 3101 LIGHTING PLAN LP3-02 FOUR SEASONS VAIL RB 1/4" = 1'-0" 1 UNIT 3101 LIGHTING PLAN 10/16/18 CEILING UPPER GYP. BOARD MUD FLANGE AT TOP AND BOTTOM LOWER 5/8" GYP. FINISHED WALL 5/8" BUILD UP . DOUBLE THICKNESS GYP. "FURRING STRIPS" FROM SCRAP OR OTHER TYPE L1 6"6" MIN.CEILING ASSEMBLY LINEAR LED TYPE L2 LIGHT POCKET WALL ASSEMBLY WALL TREATMENT TO CONTINUE INTO LIGHT POCKET 6"JBOX BY OTHERS TYPE S1, S2 LENS TOWARDS CLOSET BACK OCC SENSOR DOOR CASING DOOR SLAB L17/13 L17/13 L17/13 L17/13 L17/35L17/35 L17/35 L17/35 L17/48L17/48 L17/48 L17/48 1 1/2" = 1'-0"2 HORIZONTAL COVE DETAIL 1 1/2" = 1'-0"3 LIGHT POCKET - DIRECT COVE PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/6/2018 3:11:33 PM C:\Users\ColinInderwish\Documents\Four Seasons Vail_Lighting_Central_ryanLXJBE.rvtAs indicatedFOUR SEASONS VAILOne Vail Rd Vail, CO 81657CI RB 09/07/2018 PERMIT LIGHTING DETAILS LP3-03 FOUR SEASONS VAIL RB 1 1/2" = 1'-0"1 CLOSET LIGHT 1/2" = 1'-0"5 UNIT 3101 BATH A3-03 LIGHTING SECTION 1/2" = 1'-0"6 UNIT 3101 BATH A3-10 LIGHTING SECTION 1/2" = 1'-0" 4 UNIT 3101 BATH A3-20 LIGHTING SECTION 10/16/18 AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE ABV ABOVE BCS BUILDING CONTROL SYSTEM BDD BACK DRAFT DAMPER BLDG BUILDING BFG BELOW FINISHED GRADE BOP BOTTOM OF PIPE FROM FINISHED FLOOR B/N BETWEEN C COMMON CFM CUBIC FEET PER MINUTE (AIR FLOW RATE) CLG CEILING (OR COOLING) COND CONDENSATE CONN CONNECT (OR CONNECTION) CO CLEANOUT CW DOMESTIC COLD WATER DN DOWN (E) EXISTING EAT ENTERING AIR TEMPERATURE EC ELECTRICAL CONTRACTOR EXH EXHAUST EWT ENTERING WATER TEMPERATURE EA EXHAUST AIR ABBREVIATIONS FIXTURE CONNECTION SCHEDULE ABBR HW CW WASTE VENT WATER CLOSET LAVATORY KITCHEN SINK W/ OR W/O DISPOSER BATHTUB / SHOWER CLOTHES WASHER ROUGH-IN DISHWASHER ROUGH-IN FLOOR DRAIN HOSE BIB WC - 1/2" 3" 2" LAV 1/2" 1-1/2" 1-1/2" KS 1/2" 1/2" 2" SH 3/4" 3/4" 2" CW 1/2" 1/2" 2" DW FD HB 1/2" 1-1/2" 1-1/2" 1-1/2" - 1/2" 2" 1-1/2" - - - - -3/4" 2" 1-1/2" NOTES: 1. SIZES SHOWN ARE MINIMUM PIPE SIZES TO A SINGLE FIXTURE. LARGER SIZES MAY BE INDICATED ON PLANS WHERE REQUIRED. 2. MINIMUM DOMESTIC PIPE SIZE TO 2 OR MORE FIXTURES IS 3/4". 3. RE: MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR INDIRECT WASTE SIZES. 4. WASTE AND VENT SIZES SHOWN ABOVE APPLY TO INDIVIDUAL VENTING ONLY. WHERE ALLOWED, INDIVIDUAL VENT CONNECTIONS MAY BE OMITTED OR SIZES MAY VARY WHEN CIRCUIT VENTS, COMMON VENTS, WASTE STACK VENTS, WET VENTS, OR COMBINATION DRAIN AND VENT SYSTEMS ARE USED. PRIOR APPROVAL FROM THE ENGINEER IS REQUIRED TO USE THESE ALTERNATIVE VENTING METHODS. 5. PROVIDE TRAP PRIMER FOR ALL FLOOR DRAINS AND FLOOR SINKS NOT LOCATED IN FOOD SERVICE AREAS. 6. MINIMUM SIZE FOR WASTE AND VENT PIPING BENEATH SLAB IS 2". 7. ALL FIXTURES LISTED ARE NOT NECESSARILY USED ON THIS PROJECT. 8. REFER TO APPLIANCE SCHEDULES (BY OTHERS) FOR ADDITIONAL PLUMBING FIXTURE CONNECTIONS SUCH AS INST-HOTS, COFFEE MAKERS, AND GARBAGE DISPOSALS. 9. PROVIDE ICE MAKER BOX ROUGH IN W/ 1/2"CW CONNECTION FOR ALL REFRIGERATOR LOCATIONS. FCO FLOOR CLEANOUT FFI FOR FURTHER INFORMATION GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE (WATER FLOW RATE) HP HORSE POWER HW DOMESTIC HOT WATER LAT LEAVING AIR TEMPERATURE LWT LEAVING WATER TEMPERATURE MC MECHANICAL CONTRACTOR MFR MANUFACTURER MOD MOTOR OPERATED DAMPER (N) NEW NC NORMALLY CLOSED NO NORMALLY OPEN KW KILOWATTS OA OUTSIDE AIR OBD OPPOSED BLADE VOLUME DAMPER OSA OUTSIDE AIR RA RETURN AIR SA SUPPLY AIR SP STATIC PRESSURE TA OR TRANSFER AIR TYP TYPICAL UNO UNLESS NOTED OTHERWISE VTR VENT THROUGH ROOF RE: REFER TO: WCO WALL CLEANOUT FSD COMBINATION FIRE/SMOKE DAMPER FA FREE AREA EQUIPMENT ABBREVIATIONS AIR HANDLING UNITAHU HWC HOT WATER RECIRCULATION FAN COILFC HUMIDIFIER HC HEATING COIL HX HEAT EXCHANGER MAKE-UP AIR UNITMAU MIXING VALVEMV PUMP (SEE PIPING LEGEND FOR DETAILS)P STORAGE TANKST THERMOSTATIC MIXING VALVETMV UNIT HEATERUH WATER HEATERWH H CHILLERCH COOLING COILCC COOLING TOWERCT EXHAUST FANEF EXPANSION TANKET - PLAN SYMBOLS CONTROL PANEL/RADIANT MANIFOLD T - - - P - - S H CO P EPO CO2 SP CARBON DIOXIDE SENSOR CARBON MONOXIDE SENSOR FIRE RISER DIAGRAM CONTINUATION REFERENCE PLUMBING RISER HEATING WATER RISER THERMOSTAT HVAC RISER POINT OF NEW CONNECTION DUCT STATIC PRESSURE SENSOR ROOM PRESSURE SENSOR HUMIDISTAT REMOTE TEMPERATURE SENSOR EMERGENCY POWER OFF SWITCH ACCESS PANEL SECTION CUT LETTER/SHEET SHOWN ON POINT OF DISCONNECTION S H B W H FS PRESSURE REDUCING VALVE SHOCK ABSORBER STRAINER W/ BLOW-OFF VALVE ROOF DRAIN SAFETY RELIEF VALVE FLOOR DRAIN FLOOR SINK HORIZONTAL CLEANOUT VACUUM BREAKER VERTICAL CLEANOUT PRESSURE GAUGE W/ PIG TAIL & COCK THERMOMETER PRESSURE - TEMP. TAP AIR VENT FLEXIBLE CONNECTOR PIPE EXPANSION JOINT PIPE UNION DOUBLE CHECK BACKFLOW PREVENTER PUMP & EQUIPMENT CONNECTOR TEMPERATURE CONTROL VALVE (2-WAY) DRAIN VALVE W/ HOSE END FLOW BALANCING VALVE FLOW CONTROL VALVE BALL VALVE PLUG OR BALANCING VALVE CHECK VALVE GLOBE VALVE BUTTERFLY VALVE VENTURI/FLOW INDICATOR TEMPERATURE CONTROL VALVE (3-WAY) SOLENOID VALVE 90° ELBOW UP TEE UP TEE DOWN PIPING SYMBOLS 90° ELBOW DN SHUT OFF (BALL, GATE, BUTTERFLY) FLOW SWITCH HOSE BIBB or WALL HYDRANT TEMPERATURE CONTROLLER OR SENSORTC PIPING DESIGNATIONS HYDRONIC PIPING CHS CHILLED WATER SUPPLY CHS CHILLED WATER SUPPLY HWS HEATING WATER SUPPLY HWR HEATING WATER RETURN PLUMBING PIPING G NATURAL GAS D DRAIN PIPE DOMESTIC COLD WATER (CW) DOMESTIC HOT WATER (HW) HOT WATER RECIRCULATION (HWC) FIRE LINEF W WASTE VENTV STORM DRAINST STORM DRAIN OVERFLOWST(OF) DUCTWORK LEGEND DESCRIPTIONROUND DUCT RISER DUCT DROP 90° ELBOW DN. (NEGATIVE PRESSURE) 90° ELBOW DN. (POSITIVE PRESSURE) 90° ELBOW UP (NEGATIVE PRESSURE) 90° ELBOW UP (POSITIVE PRESSURE) SIZE OR SHAPE TRANSITION PLAN3D A 150 12x6 XFR 12x6 TYPE OF AIR DEVICE RE: GRD SCHEDULE. AIR DEVICE DESIGNATION KEY # = AIR QUANTITY (CFM) CA = COMB. AIR OSA = OUTSIDE AIR RET = RETURN EXH = EXHAUST XFR = TRANSFER FACE SIZE (INCHES) INDICATES AIR INLET DEVICE REFERENCE SAMPLE RE: B/M400 FFI NOTES FFI = FOR FURTHER INFORMATION FCT = FOR CONTINUATION SHEET NUMBER DRAWING NUMBER OR DIAGRAM LETTER REFER TO: NOTE: FOR STANDARD MODULE SIZE REGISTERS, SIZE GIVEN IS NECK SIZE. REFER TO GRD SCHEDULE FOR MODULE SIZE. B 1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONS ON LEGEND SHEET ARE NOT NECESSARILY USED ON THIS PROJECT. 2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES AND NOTATION CONVENTIONS OCCURRING IN THIS DRAWING SET ARE NECESSARILY DEFINED ON THESE LEGENDS. CONSULT THE ENGINEER IN THE EVENT SYMBOLOGY OR NOTATION INTERPRETATION IS REQUIRED. CW HW HWC RECTANGULAR 3DPLAN ROUND FLEXIBLE DUCT CONNECTION 90° RADIUS ELBOW 90° MITERED ELBOW W/ TURNING VANES-- 90° STRAIGHT TEE 90° CONICAL TEE 45° BRANCH 45° CONICAL BRANCH F/S COMBINATION FIRE AND SMOKE DAMPER F/S FIRE DAMPER SMOKE DAMPER MANUAL BALANCING DAMPER MOTORIZED DAMPER BACKDRAFT DAMPERBDD BDD D OFFSET TO CHANGE ELEVATION D = DROP R=RISE R 14ø DUCT SIZE TAG: FIRST NUMBER = PLAN WIDTH- 14x12 - MECHANICAL SYSTEMS LEGEND SERVICE SINK SK 3/4" 2" 1-1/2" 3/4" CONTRACTOR TO PROVIDE PRE-BALANCE AIRFLOW AND WATER FLOW READINGS OF ALL FAN COILS, EXHAUST, AND OUTSIDE AIR SYSTEMS. PROVIDE INFORMATION TO ENGINEER PRIOR TO DEMOLITION. ALBUQUERQUE | AVON | DENVER| FORT COLLINS 303.278.3820 www.bgbuildingworks.com Project No. 8203.02 Copyright 2018 PROJ. NO. DRAWN: CHECKED: DATE: © BG BUILDINGWORKS SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/12/2018 10:25:08 AM C:\Users\eng-ark\Documents\820302_FourSeasonsVail_mept17_eng-ark.rvt 1/8" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 ARK RSD 09/07/2018 PERMIT UNIT 4102 MECHANICAL COVER SHEET M0-01 FOUR SEASONS RESORT AT VAIL BDS FAN COIL SCHEDULE (HYDRONIC) MARK SERVICE TYPE FAN COOLING COIL HEATING COIL FILTER MANUFACTURER & MODEL # ACCESSORIES REMARKSCFM ESP @ ALT (IN WC) ELECTRICAL AIR CONDITIONS WATER CONDITIONS AIR CONDITIONS WATER CONDITIONS HP VOLT/PH E.A.T. DB/WB (°F) L.A.T. DB (°F) TOTAL MBH SENSIBLE MBH E.W.T. (°F) L.W.T. (°F) GPM MAX. WTR P.D. (FT.) E.A.T. DB (°F) L.A.T. DB (°F) SENSIBLE MBH E.W.T. (°F) L.W.T. (°F) GPM MAX. WTF P.D. (FT.) FCU-1 BEDROOM HORIZONTAL CEILING 375 0.1 1/12 120/1 75/61 55 7.5 6.0 45 55 0.8 0.00 65 90 7.5 160 140 0.75 0.00 MERV8 IEC CPY04 - A, B, C, D PLUMBING FIXTURE SCHEDULE MARK TYPE ADA FINISH MANUFACTURER* & MODEL # FAUCET TRIM MFR* & MODEL # ACCESSORIES P1 LAVATORY NOTE C REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS QUARTER-TURN 3/8" CHROME PLATED HEAVY BRASS ANGLE SUPPLY STOPS, CHROME-PLATED SOFT COPPER SUPPLY LINES. DRAIN AND OFFSET TAILPIECE, 1-1/4" 20 GAUGE CAST BRASS P-TRAP. INSULATION KIT - PRE-MANUFACTURED FOR P-TRAP, STOP VALVES AND SUPPLY LINES. P2 WATER CLOSET NOTE C REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS WHITE, EXTRA HEAVY, CLOSED FRONT, INJECTION MOLDED SOLID ANTI-MICROBIAL PLASTIC, SELF-SUSTAINING HINGE, STAINLESS STEEL OR PLATED STEEL POSTS AND NOTES. BEMIX, CHURCH, BENKE, OR SAME AS WC MFR. QUARTER-TURN 3/8" CHROME-PLATED HEAVY BRASS ANGLE SUPPLY WITH STOP, CHROME-PLATED SOFT COPPER SUPPLY LINE. P3 SHOWER NOTE C REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS SHOWER ARM, FLANGE, AND CUSTOM FLOOR DRAIN SELECTED BY INTERIOR DESIGN. P4 TUB/SHOWER NOTE C REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS - P5 BATHTUB NOTE C REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS - P6 WASHER BOX - WHITE WATER-TITE 4700 (GUY GRAY, OATEY) - - P7 LAUNDRY ROOM SINK NOTE C REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS QUARTER-TURN 3/8" CHROME PLATED HEAVY BRASS ANGLE SUPPLY STOPS, CHROME-PLATED SOFT COPPER SUPPLY LINES. DRAIN AND OFFSET TAILPIECE, 1-1/4" 20 GAUGE CAST BRASS P-TRAP. INSULATION KIT - PRE-MANUFACTURED FOR P-TRAP, STOP VALVES AND SUPPLY LINES. P8 WET BAR SINK NOTE C REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS REFER TO INTERIOR DESIGN DRAWINGS QUARTER-TURN 3/8" CHROME PLATED HEAVY BRASS ANGLE SUPPLY STOPS, CHROME-PLATED SOFT COPPER SUPPLY LINES. DRAIN AND OFFSET TAILPIECE, 1-1/4" 20 GAUGE CAST BRASS P-TRAP. INSULATION KIT - PRE-MANUFACTURED FOR P-TRAP, STOP VALVES AND SUPPLY LINES. GRILLE, REGISTER, DIFFUSER & LOUVER SCHEDULE MARK USE PATTERN FINISH MANUFACTURER* & MODEL# ACCESSORIES REMARKS A CEILING EXHAUST DOUBLE DEFLECTION WHITE TITUS 300RL OPPOSED BLADE DAMPER - B WALL SUPPLY DOUBLE DEFLECTION WHITE TITUS 272RL OPPOSED BLADE DAMPER - C WALL RETURN SINGLE DEFLECTION WHITE TITUS 271 RL - - D SUPPLY/RETURN LINEAR SLOT WHITE TITUS FL-10 - - E CEILING SUPPLY DOUBLE DEFLECTION WHITE TITUS 300RL OPPOSED BLADE DAMPER - MANUFACTURERS: * GENERAL NOTES: PRICE, KRUEGER, NIALOR, METALAIRE A: B: GENERAL NOTES: A: B: PROVIDE EPA WATER SENSE LISTED AND LABELED FIXTURE PER STATE OF COLORADO REQUIREMENTS. ALL FIXTURES LISTED ARE NOT NECESSARILY USED ON THIS PHASE OF THE PROJECT. MANUFACTURERS: * GENERAL NOTES: CARRIER, ENVIROTEC, MCQUAY, TRANE A: B: PROVIDE UNIT WITH REAR RETURN AIR. PROVIDE HONEYWELL THERMOSTAT TO MATCH EXISTING IN UNIT. THERMOSTAT SHALL HAVE 7-DAY PROGRAMMING CAPABILITY, TEMPERATURE ADJUSTMENT, AND MANUAL FAN OVERRIDE. C: PROVIDE DRAIN PAN FLOAT SWITCH IN LIEU OF SECONDARY DRAIN PAN. D: PROVIDE 3-SPEED FAN THAT RUNS ON HIGH SPEED WHILE COOLING AND MEDIUM SPEED WHILE HEATING DURING NORMAL OPERATION. MANUFACTURERS: * REFER TO SCHEDULE. FIRST LISTED IS BASIS OF DESIGN. ALL GRILLES LISTED NOT NECESSARILY USED IN THIS PROJECT PHASE. C: REFER TO ARCHITECTURAL PLANS FOR ADA REQUIREMENTS. 10/16/18 MECHANICAL SPEFICIATIONS: 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. ALL SUBCONTRACTORS SHALL BE LICENSED, EXPERIENCED, AND THOROUGHLY KNOWLEDGEABLE IN THEIR RESPECTIVE AREAS OF THE CONSTRUCTION INDUSTRY AND SHALL PERFORM IN A RESPONSIBLE MANNER WITH ESTABLISHED CONSTRUCTION SEQUENCE, SHALL RECOGNIZE THE PRIORITY OF THE CONSTRUCTION DOCUMENTS, AND SHALL INFORM THE PRIME CONTRACTOR OF POTENTIAL PROBLEMS WHEN THE CONSTRUCTION DOCUMENTS ARE UNCLEAR OR INCONSISTENT. 3. SUBCONTRACTORS SHALL BE RESPONSIBLE TO NOTIFY THE PRIME CONTRACTOR OF DISCREPANCIES OR CONFLICTS IN THE CONSTRUCTION DOCUMENTS FOUND DURING BIDDING AND/OR PRIOR TO PERFORMING THE WORK. 4. EXAMINATION OF BIDDING DOCUMENTS. A. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS CAREFULLY, AND NOT LATER THAN SEVEN (7) DAYS PRIOR TO THE DATE OF RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO THE ARCHITECT FOR INTERPRETATION OR CORRECTION OF ANY DISCREPANCIES, AMBIGUITIES, INCONSISTENCIES, OR ERRORS THEREIN WHICH HE MAY DISCOVER. THE ARCHITECT WILL ISSUE ANY INTERPRETATION OR CORRECTION AS AN ADDENDUM. ONLY A WRITTEN INTERPRETATION OR CORRECTION BY ADDENDUM SHALL BE BINDING. NO BIDDER SHALL RELY UPON INTERPRETATIONS OR CORRECTIONS GIVEN BY ANY OTHER METHOD. IF DISCREPANCIES, AMBIGUITIES, INCONSISTENCIES, OR ERRORS ARE NOT COVERED BY ADDENDUM OR WRITTEN DIRECTIVE, CONTRACTOR SHALL INCLUDE IN HIS BID, LABOR MATERIALS AND METHODS OF CONSTRUCTION RESULTING IN HIGHER COST. AFTER AWARD OF CONTRACT, NO ALLOWANCE OR EXTRA COMPENSATION WILL BE MADE ON BEHALF OF THE CONTRACTOR DUE TO HIS FAILURE TO MAKE THE WRITTEN REQUESTS AS DESCRIBED ABOVE. B. FAILURE TO REQUEST CLARIFICATION DURING THE BID PERIOD OF ANY INADEQUACY, OMISSION, OR CONFLICT WILL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES. THE SIGNING OF THE CONTRACT WILL BE CONSIDERED AS IMPLICITLY DENOTING THAT THE CONTRACTOR HAS A THOROUGH COMPREHENSION OF THE FULL INTENT AND SCOPE OF THE CONSTRUCTION CONTRACT DRAWINGS AND SPECIFICATIONS. 5. PROVIDE A BASE BID WHICH SHALL INCLUDE ONLY SPECIFIED EQUIPMENT OR EQUIPMENT LISTED AS EQUIVALENT. NO SUBSTITUTIONS FOR THE LISTED EQUIPMENT SHALL BE ALLOWED IN THE BASE BID. A. THE MANUFACTURER OF EQUIPMENT OR MATERIALS FIRST NAMED ON THE DRAWINGS IS THE BASIS OF DESIGN. OTHER MANUFACTURERS LISTED ARE CONSIDERED GENERAL EQUIVALENTS ONLY. B. COORDINATION OF GENERAL EQUIVALENTS AND SUBSTITUTIONS: WHERE CONTRACT DOCUMENTS PERMIT SELECTION FROM SEVERAL GENERAL EQUIVALENTS, OR WHERE SUBSTITUTIONS ARE AUTHORIZED, COORDINATE CLEARANCE AND OTHER INTERFACE REQUIREMENTS WITH MECHANICAL AND OTHER WORK. 1. PROVIDE NECESSARY ADDITIONAL ITEMS SO THAT SELECTED OR SUBSTITUTED ITEM OPERATES EQUIVALENT TO THE BASIS OF DESIGN AND PROPERLY FITS IN THE AVAILABLE SPACE ALLOCATED FOR THE BASIS OF DESIGN. 2) PROVIDE ALL FEATURES WHICH ARE STANDARD ON THE BASIS OF DESIGN PLUS ANY SPECIFIED OPTIONS. 3) BE RESPONSIBLE FOR ASSURING THAT PIPING, CONDUIT, DUCT, FLUE, AND OTHER SERVICE LOCATIONS FOR GENERAL EQUIVALENTS OR SUBSTITUTIONS DO NOT CAUSE ACCESS, SERVICE, OR OPERATIONAL DIFFICULTIES ANY GREATER THAT WOULD BE ENCOUNTERED WITH THE BASE DESIGN. 6. INASMUCH AS DESIGN FOR REMODEL AND/OR REHABILITATION REQUIRES THAT CERTAIN ASSUMPTIONS BE MADE REGARDING EXISTING CONDITIONS, AND BECAUSE SOME OF THESE ASSUMPTIONS CANNOT BE VERIFIED WITHOUT DESTROYING OTHERWISE ADEQUATE OR SERVICEABLE PORTIONS OF THE BUILDING, THE ENGINEER CANNOT ASSURE THE OWNER OR THE CONTRACTOR THAT THE PROFESSIONAL CONSULTING SERVICES HEREIN ENCOMPASS ALL CONTINGENCIES. FIELD COORDINATION DURING CONSTRUCTION IS IMPERATIVE. MAKE REASONABLE ALLOWANCES FOR UNSEEN CONDITIONS. 7. THE EXISTING BUILDING WILL BE OCCUPIED BY THE OWNER DURING CONSTRUCTION. CONTINUED OPERATION OF THE FACILITY SHALL NOT BE HINDERED BY THIS WORK. ACCOUNT FOR ALL ADDITIONAL COSTS WHICH MAY BE INCURRED DUE TO THE DIFFICULTY OF WORKING OVER AND AROUND EMPLOYEES, FURNITURE, EQUIPMENT, ETC.; AND DUE TO THE HOURS OF THE DAY IN WHICH AN AREA MAY BE ACCESSIBLE WHEN COMPILING BID. 8. BE RESPONSIBLE TO FIELD VERIFY EXISTING EQUIPMENT OR DUCTWORK REMAINING TO BE CONNECTED TO NEW OR EXISTING SYSTEMS. PROVIDE DUCTWORK, PIPING, CONTROLS, DIFFUSERS, ETC., AS REQUIRED TO RESTORE CONTINUITY OF SYSTEM (S), OR TO MAKE NEW WORK MEET EXISTING CONDITIONS, WHETHER INDICATED OR NOT. 9. IF NOT SPECIFICALLY DEFINED IN THESE CONSTRUCTION DOCUMENTS, MATERIALS AND/OR EQUIPMENT SHALL BE IDENTIFIED BY THE SUBCONTRACTOR WITH SUFFICIENT TIME TO ALLOW SELECTION, PURCHASE, AND DELIVERY TO MAINTAIN CONSTRUCTION SCHEDULE. 10. PROVIDE MECHANICAL DEMOLITION AS REQUIRED. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. EXISTING FIXTURES, MECHANICAL EQUIPMENT, ETC., BEING REMOVED SHALL BE RETURNED TO THE OWNER. DISPOSE OF ALL REMOVED PIPING, DUCTWORK, ETC. UNLESS NOTED OTHERWISE. PIPES, DUCTWORK, EQUIPMENT, ETC. TO BE REMOVED, ARE SHOWN HATCHED, UNLESS OTHERWISE NOTED. 11. ALL DUCTWORK, DIFFUSERS, PIPING, FIXTURES, AND EQUIPMENT SHOWN IN LIGHT LINE WEIGHT IS EXISTING, NEW INDICATED BY HEAVIER LINE WEIGHT, EXCEPT WHERE NOTED. PIPES, DUCTWORK, EQUIPMENT, ETC. TO BE REMOVED, ARE SHOWN HATCHED. 12. OFFSET PIPING, DUCTWORK, ETC. AS NECESSARY TO ACCOMMODATE STRUCTURE, BEAMS, AND COLUMNS. 13. ALL EXISTING SUPPORT RODS AND STRAPS NOW SUPPORTING DUCTS, PIPES, AIR TUBING, ELECTRICAL CONDUIT, ETC. THAT ARE REMOVED TO ALLOW ROOM FOR INSTALLATION OF NEW EQUIPMENT SHALL BE RELOCATED AND REINSTALLED, OR REPLACED IF DAMAGED. 14. ALL “CAPPED” SANITARY AND VENT LINES SHALL BE RECONNECTED OR RE-ROUTED AS NECESSARY TO PREVENT “DEAD-ENDS” IN THE PIPING. ALL PIPING SHALL DRAIN TO ACTIVE SANITARY WASTE LINES AND ALL BRANCHES WITH TRAPS SHALL BE ADEQUATELY VENTED. 15. CAP ALL DEMOLISHED AND ABANDONED DUCT TAKE-OFFS AT TRUNK DUCT. 16. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT, OWNER, AND ENGINEER. 17. IT IS THE CONTRACTOR’S RESPONSIBILITY TO PERFORM HIS/HER WORK IN CONFORMANCE WITH ALL APPLICABLE CODES, ORDINANCES AND LIFE SAFETY FEATURES AS REQUIRED BY LOCAL, STATE, OR NATIONAL AUTHORITIES. THE CONTRACTOR SHALL VERIFY WITH THE ARCHITECT IF MODIFICATION OF HIS/HER WORK IS REQUIRED FOR COMPLIANCE. 18. ALL WORK OF ALL TRADES MUST BE IN STRICT COMPLIANCE, OR EXCEED THE MINIMUM MATERIAL AND METHOD REQUIREMENTS OF THE 2015 VERSION OF THE INTERNATIONAL BUILDING, MECHANICAL, PLUMBING, ENERGY CONSERVATION, AND FIRE CODES AND THE 2017 NATIONAL ELECTRICAL CODE, MOST CURRENT NFPA, ALL LOCAL ORDINANCES AND AMENDMENTS AND MANUFACTURER’S INSTALLATION RECOMMENDATIONS. IF A CONFLICT BETWEEN THOSE PUBLICATIONS EXISTS, THE MOST STRINGENT REQUIREMENT SHALL APPLY. 19. MECHANICAL WORK SHALL CONFORM TO THE FOLLOWING CODES: ALL LOCAL. CITY, COUNTY. AND STATE CODES AMCA - AIR MOVING AND CONTROL ASSOCIATION ANSI - AMERICAN NATIONAL STANDARDS INSTITUTE ASHRAE - AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS ASTM - AMERICAN SOCIETY OF TESTING MATERIALS NFPA - NATIONAL FIRE PROTECTION ASSOCIATION OSHA - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION UL - UNDERWRITERS' LABORATORIES SMACNA - SHEET METAL AND AIR CONDITIONING NATIONAL ASSOCIATION 20. PAY FOR AND SECURE ALL REQUIRED PERMITS AND INSPECTIONS. PRIOR TO FINAL PAYMENT, TURN OVER TO ARCHITECT ALL CERTIFICATES OF COMPLETION. 21. WARRANTY THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. THE WARRANTY SHALL BE FOR A PERIOD OF ONE YEAR AFTER OWNER’S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 22. SUBMIT O&M MANUALS WITHIN 90 DAYS OF ACCEPTANCE IN ACCORDANCE WITH DIVISION 1 REQUIREMENTS. IN THE ABSENCE OF DIVISION 1 REQUIREMENTS, O&M MANUALS SHALL INCLUDE: SUBMITTAL DATA STATING SIZES AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE, MANUFACTURER’S OPERATING MANUALS AND MAINTENANCE MANUALS WITH REQUIRED ROUTINE MAINTENANCE ACTIONS IDENTIFIED, NAME AND ADDRESS OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS AND SYSTEM MAINTENANCE, RECOMMENDED SENSOR CALIBRATION SCHEDULE, WIRING DIAGRAM AND SYSTEM SCHEMATICS, AND A NARRATIVE OF HOW EACH SYSTEM IS TO OPERATE INCLUDING RECOMMENDED SETPOINTS. 23. SUBMIT RECORD DOCUMENTS TO ARCHITECT WITHIN 90 DAYS OF COMPLETION. DOCUMENTS SHALL INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS, ALTERATIONS, REROUTINGS, ETC. 24. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION PRIOR TO ACCEPTANCE BY THE OWNER. 25. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. PERFORM AT A MINIMUM ALL CODE REQUIRED TESTS OR SYSTEMS. IF TESTS OF WORK ARE DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO ADDITIONAL COST TO OWNER. 26. THE COMMISSIONING AGENT FOR THE PROJECT IS CURRENTLY UNKNOWN. THE CONTRACTOR SHALL INCLUDE IN THEIR BID ADEQUATE TIME TO PARTICIPATE IN THE IECC COMMISSIONING PROCESS WITH THE COMMISSIONING AUTHORITY (CXA). COMMISSIONED SYSTEMS INCLUDE HVAC SYSTEMS AND CONTROLS, DOMESTIC HOT WATER HEATING SYSTEMS, AND EXTERIOR LIGHTING CONTROLS. COMMISSIONING PROCESS REQUIREMENTS INCLUDE: A. INTEGRATING COMMISSIONING PROCESS ACTIVITIES PROVIDED BY THE CXA INTO THE CONSTRUCTION SCHEDULE. B. ATTENDING A CONSTRUCTION PHASE CONTROL COORDINATION MEETING C. REVIEW, ACCEPT, AND COMPLETE PREFUNCTIONAL CHECKLISTS CHECKLISTS PROVIDED BY THE CXA. SUBMIT NOTIFICATIONS OF READINESS UPON COMPLETION OF CHECKLISTS. D. REVIEW, ACCEPT, AND PARTICIPATE IN SYSTEM FUNCTIONAL PERFORMANCE TEST PROCEDURES PROVIDED AND WITNESSED BY THE CXA. E. EVALUATE PERFORMANCE DEFICIENCIES IDENTIFIED IN TEST REPORTS AND EQUIPMENT INSTALLATIONS. RECOMMEND CORRECTIVE ACTION, AND COOPERATE WITH THE CXA FOR RESOLUTION OF ITEMS. F. CERTIFY THE WORK IS COMPLETE AND SYSTEMS ARE OPERATIONAL ACCORDING TO THE CONTRACT DOCUMENTS INCLUDING CALIBRATION OF INSTRUMENTS AND CONTROLS. 27. ALL MATERIALS AND/OR EQUIPMENT SHALL BE HANDLED AND INSTALLED AS PER MANUFACTURER’S SPECIFICATIONS AND RECOMMENDATIONS. 28. SUBMIT ALL MECHANICAL DIVISION SHOP DRAWING AND PRODUCT DATA AT ONE TIME. PARTIAL SUBMITTALS WILL BE REJECTED. 29. SHOP DRAWING SUBMITTALS SHALL STATE CAPACITIES, SIZES, ETC., OF ALL EQUIPMENT AND SHALL BE CERTIFIED AND INCLUDE COMPUTER BASED PROJECT SPECIFIC SELECTIONS WHERE APPLICABLE. CLEARLY MARK EACH SHOP DRAWING, CATALOG CUT AND/OR SPECIFICATION SHEET TO INDICATE THOSE PRODUCTS AND FEATURES WHICH ARE INTENDED TO BE FURNISHED. SPECIFICALLY INDICATE ANY DEVIATIONS FROM THE DESIGN INTENT. ENGINEER RESERVES THE RIGHT TO REQUIRE CORRECTION AT NO COST TO OWNER FOR DEVIATIONS NOT SPECIFICALLY INDICATED IN THE SUBMITTALS. REVIEW AND APPROVAL OF SHOP DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF FURNISHING EQUIPMENT AND MATERIALS OF PROPER DIMENSION, SIZE, QUANTITY, QUALITY AND ALL PERFORMANCE CHARACTERISTICS TO EFFICIENTLY PERFORM THE REQUIREMENTS AND INTENT OF THE CONTRACT DOCUMENTS. SUBMITTAL SHALL BE BOUND AND INDEXED IN A NEAT AND ORDERLY MANNER. 30. SUBMITTALS SHALL INCLUDE, BUT NOT BE LIMITED TO: EQUIPMENT, FIXTURES, INSULATION, DIFFUSERS, PIPING, VALVES, CONTROLS, AND FIRE PROTECTION. 31. FAILURE TO ORDER, OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS. 32. PROVIDE NECESSARY SUPPORTS, SAWCUTTING AND PATCHING, ETC., AS REQUIRED. 33. REPAIR ALL ACCIDENTAL OR INTENTIONAL DAMAGE TO MATCH EXISTING CONSTRUCTION WITH NO NOTICEABLE DIFFERENCE IN CONTINUITY, APPEARANCE OR FUNCTION. 34. TEMPORARY HEAT SHALL BE FURNISHED BY THE GENERAL CONTRACTOR. USE OF THE PERMANENT HEATING SYSTEM WILL NOT BE ALLOWED. 35. COORDINATE ALL PENETRATIONS OF THE FLOOR SLAB PRIOR TO COMMENCING WORK. COORDINATE ALL NEW PENETRATIONS WITH OTHER DIVISIONS OF THE WORK. ALL CONTRACTORS ARE INDIVIDUALLY RESPONSIBLE FOR ALL PENETRATIONS REQUIRED BY THEIR DIVISIONS. 36. FIRE STOPPING REQUIREMENT. PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC FOR FIRE STOPS ASTM-E-814. ACCEPTABLE MATERIALS INCLUDE: DOW CORNING RTV FIRE STOP FOAM FOR BARE PIPE, METAL CONDUIT, AND ELECTRICAL CABLE; 3M FIRE DAM 150 CAULK FOR BARE PIPE, METAL CONDUIT, AND BUILDING CONSTRUCTION GAPS; 3M CP-25 CAULK AND FS-195 INTUMESCENT STRIPS FOR INSULATED PIPES, PLASTIC PIPE OR CONDUIT, AND ELECTRICAL CABLE. SUBMIT UL LISTED APPLICATION DATA FOR EACH TYPE OF PENETRATION ENCOUNTERED. 38. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR ALL CEILING PENETRATIONS AND AIR DEVICE LOCATIONS. 39. COORDINATE ARCHITECTURAL, STRUCTURAL, MECHANICAL, FIRE PROTECTION, ELECTRICAL, LANDSCAPING, AND INTERIOR DESIGN DRAWINGS PRIOR TO INSTALLATION. 40. CAREFULLY VERIFY ELECTRICAL SERVICE VOLTAGE AND PHASE AVAILABLE. 41. MOUNT ALL STATS AT 48” AFF IN “ACCESSIBLE” AREAS, 4’6” AFF IN OTHER AREAS, UNLESS NOTED OTHERWISE. COORDINATE LOCATION WITH WALL FINISH, AND TO AVOID CASEWORK, FURNITURE, DOOR SWINGS, HEAT SOURCES, AND EXTERIOR WALLS. NOTIFY ENGINEER OF ANY CONFLICTS PRIOR TO BEGINNING THERMOSTAT INSTALLATION. 42. SUBMIT A WRITTEN BALANCE REPORT BY A NEBB OR AABC CERTIFIED BALANCING CONTRACTOR. BALANCING PROCEDURES SHALL BE IN ACCORDANCE WITH NEBB OR AABC GUIDELINES FOR PROPORTIONAL BALANCE. SUBMIT REPORT ON STANDARD NEBB FORMS OR SUBMIT FORMS FOR REVIEW PRIOR TO BALANCING. MEASUREMENTS SHALL INCLUDE ALL MOTOR AMPERAGE AND VOLTAGE READINGS; MOTOR AND FAN RPMS; STATIC PRESSURE AT INLET AND OUTLET OF ALL PACKAGED EQUIPMENT, FANS, COILS, AND FILTERS; PITOT TUBE MEASUREMENT OF SUPPLY, EXHAUST, AND RETURN DUCTS; WATER FLOW AT ALL FLOW MEASUREMENT STATIONS; WATER FLOW, TEMPERATURE DROP, AND PRESSURE DROP AT ALL COILS. A. ADJUST FLOWS TO WITHIN 10% OF REQUIRED QUANTITY. IF ACTUAL QUANTITY IS LESS THAN 90%, INVESTIGATE CAUSE, ATTEMPT TO RECTIFY AND NOTIFY ENGINEER. SUBMITTAL OF BALANCE REPORT WITH LESS THAN REQUIRED FLOWS WITHOUT EXPLANATION IS CAUSE FOR REJECTION OF REPORT. B. SUBMIT THREE (3) COPIES OF ALL SUBMITTALS IN ADDITION TO ANY REQUIRED BY THE CONTRACTOR AND HIS SUPPLIERS. THESE COPIES SHALL BE RETAINED BY THE OWNER, ARCHITECT, AND ENGINEER. 43. DUCTWORK: (LOW VELOCITY) A. ROUND DUCT: SPIRAL SEAM, GALVANIZED STEEL. DIE STAMPED OR 5 GORE ELBOWS. “SNAP-LOCK”, LONGITUDINAL SEAM DUCT, OR ADJUSTABLE FITTINGS ARE ACCEPTABLE ON INDIVIDUAL GRILLE/DIFFUSER RUNOUTS ONLY. B. LINER: 1) LINE ALL SUPPLY, OUTSIDE AIR, RETURN AIR DUCTS, EXHAUST AIR RISERS, AND MAKE UP AIR RISERS WITH 1”, 1.5 LB/CF, BLACK MATTE COATED INSULATING DUCT LINER. 2) INSULATION CONDUCTIVITY VALUE NOT EXCEEDING 0.27 BTU*IN/(HR*FT^2*F). 3) LINER SHALL BE COATED AND SEALED AND SHALL MEET ASTM C1071. 4) MATERIAL SHALL MEET ALL REQUIREMENTS OF NFPA-90. 5) INSTALL WITH ADHESIVE AND WELDED PINS IN ACCORDANCE WITH SMACNA “HVAC DUCT CONSTRUCTION STANDARDS”. 6) EXTERNALLY WRAP ALL ROUND SUPPLY AIR DUCTS WITH FLEXIBLE GLASS FIBER, ANSI/ASTM C612; 0.002 INCH FOIL SCRIM FACING. 7) ALL RAW EDGES OF INSULATION SHALL BE NEATLY TRIMMED AND SEALED WITH MASTIC. C. DUCTWORK: G60 GALVANIZED SHEET STEEL; LOCK FORMING QUALITY; CONSTRUCTED TO THE LATEST EDITION OF SMACNA “HVAC DUCT CONSTRUCTION STANDARDS”; +/- 1” WC PRESSURE CLASSIFICATION, SEAL CLASS “C”; WITH GALVANIZED STEEL FASTENERS, ANCHORS, ANGLES, STRAPS, ETC. D. SEAL ALL SEAMS (LONGITUDINAL AND TRANSVERSE) AIRTIGHT WITH UNITED MCGILL “UNI-GRIP” UL LISTED, WATER BASED, NON-HARDENING, ELASTIC SEALANT OR EQUIVALENT. TAPE NOT ALLOWED. 44. ALL DUCTWORK DIMENSIONS ARE OUTSIDE SHEET METAL DIMENSIONS. DUCT LINER HAS BEEN ACCOUNTED FOR WITHIN RECTANGULAR DUCTWORK. 45. DUCTWORK NOTES: A. UNLESS OTHERWISE NOTED, ALL CHANGES IN DIRECTION SHALL BE MADE WITH RADIUS ELBOWS WITH RADIUS TO CENTERLINE EQUAL TO 1.5 DUCT WIDTH. 1) WHERE REQUIRED FOR SPACE CONSTRAINTS, PROVIDE SQUARE THROAT ELBOWS WITH SINGLE WIDTH (NON-AIRFOIL) TURNING VANES. 2) PROVIDE MANUFACTURED SINGLE WIDTH (NON-AIRFOIL) TURNING VANES, WITH SPACING IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS FOR “STANDARD SPACING”. B. RETURN AIR PLENUM: THE HVAC SYSTEM WILL USE THE SPACE ABOVE THE CEILING ON EACH FLOOR AS A RETURN AIR PLENUM. CONFORM TO THE REQUIREMENTS OF NFPA AND LOCAL CODE REQUIREMENTS FOR ALL MATERIAL INSTALLED IN THE RETURN AIR PLENUM. PROVIDE A COMPLETE RETURN AIR PATH BETWEEN ALL RETURN AIR DEVICES (GRILLES ETC.) AND THEIR RESPECTIVE HVAC UNIT. MAXIMUM VELOCITY OF RETURN AIR IN PLENUM SHALL GENERALLY NOT EXCEED 250 FEET PER MINUTE, NOR EXCEED 750 FEET PER MINUTE AT ANY CROSS-SECTION OF THE RETURN AIR PATH. 46. DUCTWORK SPECIALTIES A. VOLUME AND SPLITTER DAMPERS: GALVANIZED SHEET METAL WITH VENTFABRICS, INC., VENTLOCK OR EQUAL OPERATING HARDWARE. FOR ACCESSIBLE DAMPERS, PROVIDE NO. 620, 635 OR 637 DIAL REGULATORS, NO. 635 OR 637 SQUARE END BEARING, AND NO. 635 SPRING END BEARING, AS APPLICABLE. FOR INACCESSIBLE DAMPERS, PROVIDE NO. 666 CONCEALED DAMPER REGULATOR, WITH PAINTED COVER (COLOR BY ARCHITECT) AND BEARINGS AS ABOVE. B. TURNING VANES FOR LOW PRESSURE DUCTS: SMACNA SMALL DOUBLE VANE, PLATE NO. 22B OR EQUAL, WITH AIRFOIL BLADES FOR DUCTS 36" OR LESS IN WIDTH; SMACNA FIG. 3.23 FOR DUCTS GREATER THAN 36" WIDE. FOR MEDIUM PRESSURE DUCTS: SMACNA FIG. 3-23. C. ACCESS PANELS: 1) REINFORCED, GALVANIZED SHEET METAL WITH AIRTIGHT GASKETS RATED FOR PRESSURES AND SERVICE INTENDED. MILCOR OR EQUAL. PROVIDE HINGES AND VENTFABRICS, INC. VENTLOCK LATCHES. 2) DUCT ACCESS PANELS FOR HAND ENTRY ONLY: NO. 90 SASH TYPE LATCH. MINIMUM SIZE: 18" X 18". 3) DUCT AND PLENUM ACCESS DOORS FOR BODY ENTRY: NO. 310 LATCH, OPERABLE FROM BOTH SIDES OF DOOR. MINIMUM SIZE: 18" X 18". 4) REFERENCE OTHER SECTIONS FOR CEILING/ WALL ACCESS PANELS. 47. SUPPORT PIPE WITH ROD AND CLEVIS, RING HANGERS, TRAPEZE, OR CLAMPS. NO PIPE TAPE OR STRAPPING ALLOWED. ALL HANGERS SHALL BE SIZED FOR OD OF INSULATION, IF ANY. PROTECT INSULATED LINES WITH 20 GA SHEET METAL SHIELDS AND PROVIDE CALCIUM SILICATE INSULATION INSERTS FOR ALL INSULATED PIPING. MAINTAIN VAPOR BARRIER ON ALL COLD LINES. ISOLATE BARE COPPER LINES FROM HANGERS WITH VIBRASORB OR EQUIVALENT, COPPER COATED HANGERS ARE NOT SUFFICIENT, WRAPPING PIPE WITH TAPE NOT ACCEPTABLE. 48. NEW HOT AND COLD WATER BRANCHES TO BE ROUTED FROM NEAREST HOT WATER AND COLD WATER OF LINE SIZE EQUAL TO OR GREATER THAN NEW BRANCH—TYPICAL. 49. REFER TO PLUMBING FIXTURE CONNECTIONS SCHEDULE FOR PIPE SIZES TO INDIVIDUAL PLUMBING FIXTURES. 50. PROVIDE SHOCK ARRESTERS AT ALL DOMESTIC HOT AND COLD WATER BRANCHES SERVING FIXTURES AND EQUIPMENT WITH QUICK CLOSING VALVES. SUCH FIXTURES AND EQUIPMENT INCLUDES DISHWASHERS AND CLOTHES WASHERS. SHOCK ARRESTERS SHALL BE CONSTRUCTED WITH A PISTON IN A SEALED COPPER TUBE CHAMBER, AND APPROVED FOR INSTALLATION WITHIN WALLS WITHOUT ACCESS PANELS. SIOUX CHIEF OR EQUIVALENT. BELLOWS TYPE NOT ACCEPTABLE. 51. DOMESTIC HOT AND COLD PIPING INSIDE BUILDING—NON-BURIED LINES, TYPE “L” HARD COPPER WATER TUBE, WROUGHT COPPER FITTINGS AND NO LEAD 95-5 SOLDER. 52. COPPER PIPE VALVES AND SPECIALTIES A. GATE VALVES - BRONZE, CLASS 125, 200 LB. W.O.G. B. BALL VALVES - BRONZE, CLASS 125, 600 LB. W.O.G. C. CHECK VALVES - BRONZE, CLASS 125, 200 LB. W.O.G. D. BALANCING VALVES - 125 PSI W.P. FOR 250 DEGREE FAHRENHEIT SERVICE TIGHT SHUTOFF, TOUR AND ANDERSON STA, ARMSTRONG CBV, GERAND, OR FLOWSET, B&G CIRCUIT SETTER. E. DIRECT UNIONS: FURNISH AND INSTALL A DIELECTRIC UNION AT EACH CONNECTION BETWEEN DISSIMILAR METALS. 53. MATERIALS; SOIL, WASTE, AND VENT PIPING (INSIDE BUILDING) A. LINES ABOVE GROUND: STANDARD WEIGHT, CAST IRON SOIL PIPE, AND FITTINGS. HUB AND SPIGOT WITH NEOPRENE GASKETS, OR NO HUB WITH STANDARD CLAMPS. UP THROUGH 2-1/2” MAY BE STANDARD WEIGHT, GALVANIZED STEEL PIPE WITH BLACK, WROUGHT IRON DRAIN FITTINGS, OR DWV COPPER TUBE WITH DWV FITTINGS AND 95-5 NO LEAD SOLDER. 54. GAS PIPING: SCHEDULE 40 BLACK STEEL PIPE, 150 LB. MALLEABLE IRON SCREWED FITTINGS ON ABOVE GROUND PIPE, WELDED FITTINGS WITH ALL PIPING COATED AND WRAPPED ON BURIED PIPE. 55. GAS VALVES: NON-LUBRICATED BALL STYLE VALVE WITH RESILIENT SEATS, AND ADJUSTABLE GLAND PACKING NUT, AGA AND UL LISTED FOR NATURAL GAS SERVICE. 56. PROVIDE EXPANSION JOINTS OR LOOPS ON ALL CHILLED AND HEATING WATER PIPING RUNS IN EXCESS OF 50 FEET AND IN ACCORDANCE WITH THE MANUFACTURER’S RECOMMENDATIONS. 57. GRADE AND VALVE ALL HEATING AND CHILLED WATER PIPING WITH 3/4” HOSE END VALVES TO PERMIT COMPLETE DRAINAGE OF THE SYSTEM. ALL HIGH POINTS IN SYSTEM OUTSIDE OF EQUIPMENT ROOMS WITH COMBINATION AUTOMATIC/MANUAL AIR VENTS AS REQUIRED TO RELIEVE AIR IN THE SYSTEM. 58. MATERIALS; HYDRONIC PIPING A. ABOVE GRADE, UP THROUGH 2-1/2”: SCHEDULE 40 STEEL PIPE WITH MALLEABLE IRON THREADED FITTINGS, OR TYPE “L” COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95-5 NO LEAD SOLDER. 59. DRAIN PAN PIPING: NOT BURIED: TYPE “M” COPPER, WROUGHT COPPER FITTINGS, AND 95-5 SOLDER; BURIED: TYPE “L” COPPER WROUGHT COPPER FITTINGS, AND 95-5 SOLDER. ALL BURIED PIPE SHALL BE SURROUNDED WITH 4” OF CLEAN SAND. 60. SUPPORT EACH FAN COIL BY MASON INDUSTRIES OR EQUIVALENT SPRING TYPE VIBRATION ISOLATORS. 61. INDOOR PIPING INSULATION - INSULATE ALL NEW HEATING WATER, CHILLED WATER, DOMESTIC WATER, DOMESTIC HOT WATER, DOMESTIC HOT WATER RECIRCULATION PIPING WITH UL APPROVED, WHITE, ALL SERVICE, MINERAL FIBER, SNAP-ON, PIPE INSULATION. INSULATE FITTINGS WITH MINERAL FIBER BLANKET INSULATION AND PRE-MOLDED PVC COVERS. ALL MATERIALS SHALL HAVE A SMOKE DEVELOPED RATING OF 50 OR LESS AND A FLAME SPREAD RATING OF 25 OR LESS. PROVIDE CALCIUM SILICATE THERMAL INSERT AT HANGERS AND SUPPORTS. INSULATION SHALL PASS UNINTERRUPTED THROUGH HANGERS. VAPOR BARRIERS SHALL BE CONTINUOUS, AND SEALED WITH “NON-BREATHING” VAPOR BARRIER MASTIC ON PIPING OPERATING AT TEMPERATURES BELOW AMBIENT. ALL RAW EDGES OF INSULATION SHALL BE NEATLY TRIMMED AND SEALED WITH MASTIC. A. INSULATION THICKNESS BELOW BASED ON INSULATION CONDUCTIVITY VALUE NOT EXCEEDING 0.27 BTU*IN/(HR*FT^2*°F): 1) HEATING WATER (LESS THAN 200°F) – NPS 1.25 AND LESS, 1.5” THICK; NPS 1.5 AND GREATER, 2” THICK. RUNOUTS WITHIN 4 FEET OF TERMINAL AND 1” PIPE DIAMETER OR LESS, 1” THICK. 2) CHILLED WATER, BRINE AND REFRIGERANT (NOT LESS THAN 40°F) – NPS 1.25 AND LESS, 0.5” THICK; NPS 1.25 AND GREATER, 1” THICK. 3) DOMESTIC HOT WATER (DHW) AND DOMESTIC HOT WATER RECIRCULATION: ALL PIPE SIZES – 1” THICK; NON-RECIRCULATED DHW RUNOUTS WITHIN 8 FEET OF FIXTURES – 1/2” THICK. 4) DOMESTIC COLD WATER: ALL PIPE SIZES – 1/2” THICK. 62. CLEAN, STERILIZE, FLUSH AND FILL ALL NEW SYSTEMS PRIOR TO STARTUP. INCLUDE LABOR AND MATERIALS FOR FINAL FILL OF WATER. 63. IDENTIFICATION: LABEL ALL NEW PIPING AND EQUIPMENT. PROVIDE FULL BAND OR STRIP TYPE MARKERS AND FLOW ARROWS ON PIPING. PROVIDE ENGRAVED PLASTIC VALVE TAGS WITH VALVE NUMBER AND ATTACH WITH STANDARD CHAIN OR S-HOOKS. PROVIDE ENGRAVED PLASTIC SIGN ON OR NEAR SPECIFIED EQUIPMENT. WALL CLEANOUT DIAGRAM NO SCALE1'-0"MAY EXTEND AS A WASTE OR VENT. CHROME WALLCOVER AND SCREW. PLUGGED TEE WITH CLEANOUT. WALL. FLOOR LINE. 1/8 C.I. BEND. BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. E TYPICAL HANGER DIAGRAM NO SCALE ANCHOR, REFER TO STRUCTURAL. THREADED ROD. HANGER. PIPE. CONCRETE STRUCTURE. NOTE: ALL PIPING WITH INSULATION TO HAVE INSULATION RUN FULL SIZE THROUGH HANGER WITH SHIELD AND INSERT. D 45° DUCT TAKE- OFF DIAGRAM NO SCALE 45° W H 1/4 OF "W" OR 6" MINIMUM. END BEARING. SINGLE BLADE DAMPER IF H<8" OPPOSED BLADE DAMPER IF H>=8" SEAL AIRTIGHT AROUND ENTIRE TAKE-OFF. C CEILING SA FAN COIL UNIT FILTER W/ ACCESS PANEL. CONDENSATE DRAIN. PIPE INDIRECT TO APPROVED RECEPTOR (PROVIDE MIN. 2" DEEP TRAP). SHEET METAL DRAIN PAN. 3/4" SECONDARY DRAIN TO APPROVED RECEPTOR. PIPE INDIRECT TO FLOOR DRAIN ON SINK TAIL PIECE, TYP. ROUND HANGER ROD TYP. WITH EXCEPTION OF FAN COILS LOCATED IN ATTIC. SPRING VIBRATION ISOLATORS, TYP. DOUBLE LOCKNUT. FAN COIL UNIT INSTALLATION NO SCALE D D A RETURN SUPPLY 2-WAY COIL PIPING DIAGRAM NO SCALE B COIL NOTES: 1. FLEXIBLE PIPE CONNECTOR REQ'D FOR EQUIPMENT CONTAINING FANS OR COMPRESSORS, NOT REQ'D FOR EQUIPMENT SUCH AS DUCT COILS. 2. PIPE ALL MULTI-ROW COILS FOR COUNTERFLOW (WATER ENTERS MOST DOWNSTREAM COIL, LEAVES MOST UPSTREAM COIL). 3. REFER TO CONTROLS DRAWINGS FOR ADDITIONAL INFORMATION. 4. 2-WAY VALVE NORMALLY OPEN FOR HEATING AND NORMALLY CLOSED FOR COOLING. STRAINER WITH BLOWDOWN AND CAP. MANUAL AIR VENT AT HIGHEST POINT IN PIPING. ISLAND VENT DIAGRAM NO SCALE WVFLOOR V DRAINBOARD 2" SLOPE 2" C.O. SLOPE 1. EXTEND VENT AS HIGH AS POSSIBLE BUT NOT LESS THAN THE DRAINBOARD HEIGHT & THEN RETURNING IT DOWNWARD & CONNECTING IT TO THE HORIZONTAL SINK DRAIN IMMEDIATELY DOWNSTREAM FROM THE VERTICAL FIXTURE DRAIN. 2. THE RETURNED VENT SHALL BE CONNECTED TO THE HORIZONTAL DRAIN THRU A Y-BRANCH FITTING & SHALL, IN ADDITION, BE PROVIDED WITH A FOOT VENT TAKEN OFF THE VERTICAL FIXTURE VENT BY MEANS OF A Y-BRANCH IMMEDIATELY BELOW THE FLOOR & EXTENDING TO THE NEAREST PARTITION & THEN THRU THE ROOF OR CONNECTED TO OTHER VENTS, IN AN APPROVED MANNER. 3. DRAINAGE FITTINGS SHALL BE USED ON ALL PARTS OF THE VENT BELOW THE FLOOR & A MIN. SLOPE OF 1/4"/FT BACK TO THE DRAIN SHALL BE MAINTAINED. 4. THE RETURN DRAIN UNDER THE DRAINBOARD SHALL BE A ONE PIECE FITTING OR AN ASSEMBLY OF A 45°, A 90°, & A 45° IN THE ORDER NAMED. 5. THE ISLAND SINK DRAIN, UPSTREAM OF THE RETURNED VENT, SHALL SERVE NO OTHER FIXTURES. VENT LINE NEAREST PARTITION . WALL CLEANOUT 1-1/2" 1-1/2" SINK DRAIN TO BUILDING SEWER. REQUIREMENTS F ALBUQUERQUE | AVON | DENVER| FORT COLLINS 303.278.3820 www.bgbuildingworks.com Project No. 8203.02 Copyright 2018 PROJ. NO. DRAWN: CHECKED: DATE: © BG BUILDINGWORKS SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/12/2018 10:25:09 AM C:\Users\eng-ark\Documents\820302_FourSeasonsVail_mept17_eng-ark.rvt 1/8" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 09/07/2018 PERMIT MECHANICAL SPECIFICATIONS M0-02 FOUR SEASONS RESORT AT VAIL Approver 10/16/18 REF3.7 4 4.4 5 5.44.2 A10 A11 A12 A13 A9.9 22x622x614x8 8x6 6x6 8x612x6 8x612x8 12x8 26x106ø 8x6 6x6F/S 1 2 1 2 1 2 1 1 2 1 2 DISCONNECT DUCTWORK AND PREPARE FOR REUSE CAP DUCTWORK AND SEAL AIRTIGHT F/S 1 DISCONNECT DUCTWORK AND PREPARE FOR REUSE 8ø DISCONNECT DUCTWORK AT RISER AND SEAL RISER AIRTIGHT 8x6 (E) 10x10 EXHAUST RISER. (E) 16x16 OUTSIDE AIR RISER. (E) 18x8 EXHAUST RISER. (E) 8x6 KITCHEN EXHAUST RISER. (E) EXHAUST DUCTWORK TO REMAIN. (E) EXHAUST DUCTWORK TO REMAIN. (E) OUTSIDE AIR DUCTWORK TO REMAIN. DISCONNECT DUCTWORK AT RISER AND SEAL RISER AIRTIGHT (E) 16x12 EXHAUST RISER. REMOVE (E) FIREPLACE FLUE AND WALL TERMINATION. PREPARE EXTERIOR WALL PENETRATION FOR REUSE. DISCONNECT AND REMOVE RANGE HOOD. PREPARE DUCTWORK FOR REUSE. (E) FCU (E) FCU (E) FCU DISCONNECT DUCTWORK AT MAIN AND SEAL AIRTIGHT. 3.7 4 4.4 5 5.4 4.2 A10 A11 A12 A13 A9.9 BEDROOM A3-05 BEDROOM A3-13 BEDROOM A3-23 LIVING ROOM A3-24 BATH 02 A3-26 HALL A3-27 BATH 01 A3-20 HALL A3-21 CLOSET A3-22 BATH A3-10 HALL A3-11 CLOSET A3-12 HALL 01 A3-01 HALL A3-02 CLOSET A3-04 BATH A3-03 36x6 8x6 26x10 8x66x614x8 x RA C1810 x SA B1810 x 390 B1810 16x8 16x8 x 210 D481TYP 2 x RA D481TYP 2 x RA C1810 RETURN AIR GRILLE OPEN TO PLENUM, TYP UNO 16x8 x SA B181022x6 8x6 3 8x638x6 8x6F/S F/S 3 x 25 A66 8x66x6 F/S (E) FCU (E) FCU (E) FCU x 25 A66 6x6 3 14x8 (E) FCU TO REMAIN. (E) FCU TO REMAIN. (E) FCU TO REMAIN. CONNECT 16x8 SA TO (E) 26x10 SUPPLY DUCT. CONNECT 8x6 EXH TO (E) 8x6 EXHAUST DUCT. (E) 10x10 EXHAUST RISER. (E) 16x16 OUTSIDE AIR RISER. (E) 18x8 EXHAUST RISER. (E) 8x6 KITCHEN EXHAUST RISER. (E) 16x12 EXHAUST RISER. MATCH (E) GRILLE SIZE, TYP. PROVIDE DURAVENT SQUARE HORIZONTAL H2 TERMINATION CAP. COORDINATE COLOR SELECTION WITH ARCHITECT. REFER TO FIREPLACE IOM FOR VENTING AND FLUE REQUIREMENTS. PROVIDE DURAVENT DIRECT VENT FLUE SYSTEM WITH ALUMINUM INNER WALL AND GALVANIZED STEEL OUTER WALL. 8" Ø FLUE DN TO FIREPLACE BY OTHERS 8ø F/S 22x6EXTEND (E) DUCTWORK TO NEW GRILLE. LIVING ROOM GRILLES LOCATED ON VERTICAL FACE OF SOFFIT. ALBUQUERQUE | AVON | DENVER| FORT COLLINS 303.278.3820 www.bgbuildingworks.com Project No. 8203.02 Copyright 2018 PROJ. NO. DRAWN: CHECKED: DATE: © BG BUILDINGWORKS SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/12/2018 10:25:11 AM C:\Users\eng-ark\Documents\820302_FourSeasonsVail_mept17_eng-ark.rvt 1/4" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 09/07/2018 PERMIT UNIT 3101 DEMO & HVAC PLANS M3-01 FOUR SEASONS RESORT AT VAIL BDS SCALE:1/4" = 1'-0"1 UNIT 3101 HVAC DEMOLITION PLAN SCALE:1/4" = 1'-0"2 UNIT 3101 HVAC PLAN NOTES: 1. COORDINATE ALL CUTTING AND PATCHING OF WALLS, CEILINGS, AND FLOORS WITH GC. 2. RE: D/M0-02 FOR TYPICAL HANGER DIAGRAM. 3. RE: E/M0-02 FOR WALL CLEANOUT DIAGRAM. # FLAG NOTES: 1 READ AIRFLOW AND PROVIDE ENGINEER WITH WRITTEN REPORT OF AIRFLOWS PRIOR TO DEMOLITION. 2 REMOVE EXISTING GRILLE. 3 REBALANCE AIRFLOW TO MATCH EXISTING. 10/16/18 REFL E3.7 4 4.4 5 5.44.2 A10 A11 A12 A13 A9.9 (E)1/2" CW(E)1 1/4" G EXISTING GAS RISER GR#R3,DEMO PIPING IN CEILING BELOW UP TO ABOVE CEILING; PREPARE PIPING FOR REUSE DISCONNECT EXISTING WASHER BOX AND DEMO WASTE, VENT, AND DOMESTIC WATER PIPING BACK TO MAIN. CAP PIPING AT MAINS. DISCONNECT AND REMOVE EXISTING KITCHEN SINK, FAUCET, DISPOSER, AND DISHWASHER; DEMO WASTE, VENT, AND DOMESTIC WATER PIPING SERVING KITCHEN BACK TO MAIN. PREPARE MAINS FOR REUSE. DISCONNECT AND REMOVE ALL PLUMBING FIXTURES CONNECTED TO RISER PS#R5; PREPARE PIPING FOR REUSE EXISTING RISER PS#R5 TO REMAIN DISCONNECT AND REMOVE ALL PLUMBING FIXTURES CONNECTED TO RISER PS#R4; PREPARE PIPING FOR REUSE EXISTING RISER PS#R4 TO REMAIN (E) STEAM GENERATOR TO REMAIN DISCONNECT (E) STEAM PIPING AND PREPARE FOR REUSE (E) RISERS PS#R7 AND GR#R9 3.7 4 4.4 5 5.4 4.2 A10 A11 A12 A13 A9.9 BEDROOM A3-05 BEDROOM A3-13 BEDROOM A3-23 LIVING ROOM A3-24 BATH 02 A3-26 HALL A3-27 CLOSET A3-25 BATH 01 A3-20 HALL A3-21 CLOSET A3-22 BATH A3-10 HALL A3-11 CLOSET A3-12 HALL 01 A3-01 HALL A3-02 CLOSET A3-04 BATH A3-03 INSTALL NEW SINKS, SHOWER, AND WATER CLOSET AND CONNECT TO (E) PIPING ON RISER PS#R4 CONNECT 2"V, 1"CW/HW TO (E) RISER PS#R5 INSTALL NEW SINKS, BATHTUB, AND WATER CLOSET AND CONNECT TO (E) PIPING ON RISER PS#R5 REFER TO DRAWING 3 ON THIS SHEET FOR BELOW FLOOR WASTE AND VENT PIPING RELOCATE (E) GAS RISER GR#R3 INTO WALL, CONNECT TO EXISTING PIPING AND TO NEW FIREPLACE.1" CW1" HW2" V1-1/2" V DN1" CW1" HW2" VP2 P1 P3 P5 P2 P3 P1 P3 TYP 2 TYP 3 CONNECT 1 1/2"V, 3/4"CW/HW TO (E) RISER PS#R7 1 1/2"V DN, TYP UNO P5 P2 P7 P7 1-1/2" V DN CONNECT (E) STEAM PIPING AS REQUIRED TO NEW SHOWER. WCO P8 3/4" CW 3/4" HW 3/4" CW 2" V 3.7 4 4.2 A11 A12 A13 WC LAV SH SH TUB WC LAV LAV SH 2" W 2" W 3" W3" W3" WCONNECT 3"W TO (E) RISER PS#R5 2" W 2"V UP WCO CONNECT 2"W TO (E) RISER PS#R7 1 1/2"V UP, TYP UNO 2" V UP SK ALBUQUERQUE | AVON | DENVER| FORT COLLINS 303.278.3820 www.bgbuildingworks.com Project No. 8203.02 Copyright 2018 PROJ. NO. DRAWN: CHECKED: DATE: © BG BUILDINGWORKS SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/12/2018 10:25:12 AM C:\Users\eng-ark\Documents\820302_FourSeasonsVail_mept17_eng-ark.rvt 1/4" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 Author Checker 09/07/2018 PERMIT UNIT 3101 DEMO AND PLUMBING PLANS M3-02 FOUR SEASONS RESORT AT VAIL Approver SCALE:1/4" = 1'-0"1 UNIT 3101 PLUMBING DEMOLITION PLAN SCALE:1/4" = 1'-0"2 UNIT 3101 PLUMBING PLAN SCALE:1/4" = 1'-0"3 UNIT 3101 PLUMBING BELOW FLOOR PLAN NOTES: 1. COORDINATE CUTTING AND PATCHING OF WALLS, CEILINGS, AND FLOORS WITH GC. 2. RE: D/M0-02 FOR TYPICAL HANGER DIAGRAM. 3. RE: E/M0-02 FOR WALL CLEANOUT DIAGRAM. 10/16/18 ISSUE LOG KEY: '√ ' ' ' ' * ' ISSUED AS PART OF SET NOT PART OF SET ISSUED FOR INFORMATION ONLY TECHNOLOGY SYSTEMS LEGEND ABBREVIATIONS AFC ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AP ACCESS POINT C CONDUIT CATV COMMUNITY (CABLE) ANTENNA TELEVISION SYSTEM CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT (E) EXISTING EM EMERGENCY FA FIRE ALARM FBO FURNISHED BY OTHERS GC GENERAL CONTRACTOR GRD GROUND IAW IN ACCORDANCE WITH IC INTERMEDIATE CROSS-CONNECT IDF INTERMEDIATE DISTRIBUTION FRAME IG ISOLATED GROUND IR INFRARED LAN LOCAL AREA NETWORK MDF MAIN DISTRIBUTION FRAME (N) NEW NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER PA PUBLIC ADDRESS UNO UNLESS NOTED OTHERWISE WAN WIDE AREA NETWORK WAP WIRELESS ACCESS POINT WLAN WIRELESS LOCAL AREA NETWORK WP WEATHERPROOF +18" MOUNTING HEIGHT TO CENTERLINE OF DEVICE ABOVE FINISH FLOOR (VERIFY W/ ARCH ELEVATIONS) AUDIOVISUAL SYMBOLS TV TELEVISION OUTLET - WALL MOUNTED SPK TV TELEVISON OUTLET - CEILING MOUNTED TV TELEVISION OUTLET - FLOORBOX AV AUDIOVISUAL OUTLET - WALL MOUNTED AV AUDIOVISUAL OUTLET - CEILING MOUNTED AV AUDIOVISUAL OUTLET - FLOORBOX S LOUDSPEAKER - CEILING MOUNTED S LOUDSPEAKER - WALL MOUNTED LOUDSPEAKER OUTLET S LOUDSPEAKER - POWERED SUBWOOFER LCR LOUDSPEAKER BAR - LEFT/CENTER/RIGHT LR LOUDSPEAKER BAR - STEREO CTR LOUDSPEAKER BAR - CENTER CHANNEL M MICROPHONE OUTLET - FLOORBOX M MICROPHONE OUTLET - WALL MOUNTED INTERACTIVE (ELECTRONIC) WHITEBOARD PROJECTION SCREEN, TV, OR OTHER DISPLAY EQPT VIDEO PROJECTOR SPEAKER ZONE HOMERUN VOICE/DATA SYMBOLS TELEPHONE WALL OUTLET DOUBLE TELEPHONE WALL OUTLET TELEPHONE FLOOR OUTLET DATA WALL OUTLET DATA WALL OUTLET DATA FLOOR OUTLET COMBO PHONE/DATA OUTLET DOUBLE COMBO PHONE/DATA OUTLET COMBO PHONE/DATA FLOOR OUTLET VOICE/DATA/FIBER OUTLET POINT OF SALE (POS) OUTLET AUTOMATED TELLER MACHINE (ATM) STATION PUBLIC PAYPHONE OUTLET ELEVATOR PHONE OUTLET FAX/COPIER OUTLET EMERGENCY SERVICES PHONE OUTLET POWER/TELECOM POLE WIRELESS LAN (WI-FI) ACCESS POINT OUTLET MULTI-OUTLET WIREWAY OF POS ATM PP E F EM ALBUQUERQUE | AVON | DENVER| FORT COLLINS 303.278.3820 www.bgbuildingworks.com Project No. 8203.02 Copyright 2018 PROJ. NO. DRAWN: CHECKED: DATE: © BG BUILDINGWORKS SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/12/2018 4:04:21 PM C:\Users\eng-keh\Documents\820302_FourSeasonsVail_mept17_eng-keh.rvt 1/8" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 KEH ETA 09/12/2018 PERMIT UNIT 3101 TECHNOLOGY COVER SHEET T3-01 FOUR SEASONS RESORT AT VAIL ELR TECHNOLOGY SHEET INDEX - PHASE 3 # TITLE ISSUE LOG PERMIT SET - 09.12.18T3-01 UNIT 3101 TECHNOLOGY COVER SHEET √ T3-02 UNIT 3101 TECHNOLOGY SPECIFICATIONS T3-03 UNIT 3101 TECHNOLOGY PLAN √ GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK. 2. WORK ASSOCIATED WITH TECHNOLOGY SYSTEMS REQUIRES CAREFUL, DETAILED COORDINATION, BOTH PREPARTORY AND ON- SITE, BETWEEN THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR, AND THE TECHNOLOGY SYSTEMS CONTRACTOR(S). LACK OF PLANNING, COORDINATION, OR SKILL ON PART OF ANY PARTY ASSOCIATED WITH THE SCOPE OF WORK INDICATED WILL NOT BE ACCEPTED AS REASON FOR INSTALLATION THAT DOES NOT MEET SPECIFICATIONS OR INDUSTRY STANDARDS. 3. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. 4. IF WORK ON LIVE NETWORKS OR SYSTEMS IS TO BE DONE, SYSTEM DOWNTIME SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER – IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OUTAGE SHALL BE PERFORMED WITHTHE OWNER’S IT/IS STAFF AND/OR MAINTENANCE PERSONNEL ADVISED AND AWARE OF SUCH WORK. 5. COMMUNICATIONS SERVICES SHALL BE MAINTAINED TO EXISTING AREAS DURING CONSTRUCTION IF SUCH AREAS ARE TOREMAIN LIVE. CONTRACTOR SHALL PROVIDE NECESSARY MEANS AND PROTECTION TO ENSURE UPTIME. 6. REVIEW ENTIRE CONTRACT DOCUMENT PACKAGE (INCLUDING ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND OTHER DRAWINGS AND SPECIFICATIONS) PRIOR TO BID. 7. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT AND ENGINEER. 8. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL AND STATE ADOPTED CODES ANDORDINANCES. 2014 EDITION OF NFPA 70 – NATIONAL ELECTRICAL CODE SHALL BE MET AT A MINIMUM. APPLICABLE VOLUMES OF NFPA (NFPA 72, NFPA 75, NFPA 76, NFPA 99, NFPA 101, ETC.) SHALL BE ADHERED TO AT A MINIMUM. 9. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST APPLICABLE STANDARDS AND RECOMMENDATIONS AS PUBLISHED BY AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA),ELECTRONIC INDUSTRIES ALLIANCE (EIA), INSULATED CABLE ENGINEERS ASSOCIATION (ICEA), INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE), SECURITY INDUSTRY ASSOCIATION (SIA), BUILDING INDUSTRY CONSULTING SERVICES INTERNATIONAL (BICSI), AND INFOCOMM INTERNATIONAL. 10. PROVIDE WITH SHOP DRAWING SUBMITTAL, 1/4” SCALE LAYOUT DRAWINGS OF ROOMS WITH COMMUNICATIONS, AUDIOVISUAL, AND SECURITY DISTRIBUTION OR HEAD-END EQUIPMENT. LAYOUTS SHALL SHOW LOCATIONS OF, AND SHALL BE COORDINATED WITH ELECTRICAL AND MECHANICAL EQUIPMENT. ALL EQUIPMENT SHALL BE DRAWN TO SCALE. 11. CONTRACTOR’S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS. 12. VERIFY EXACT LOCATIONS OF EXISTING AND NEW UNDERGROUND UTILITIES, PIPING, AND RACEWAY SYSTEMS PRIOR TO TRENCHING. PROVIDE NECESSARY TRENCHING, BACKFILL, EXCAVATION, SUPPORTS, BACKBONES/SERVICE ENTRANCES (CONDUIT AND/OR CABLING), PULLBOXES, HANDHOLES, MANHOLES, PEDESTALS, SAWCUTTING AND PATCHING, CONCRETE/PAVING, ETC. REQUIRED. BACKFILL TRENCHES TO 90 PERCENT COMPACTION AND PATCH TO MATCH EXISTING. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT SERVICE PROVIDER DRAWINGS AND REQUIREMENTS. CONTRACTOR IS TOSUBMIT A COMPLETE CONSTRUCTION DRAWING SET TO THE SERVICE PROVIDERS WITHIN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THEIR REVIEW, APPROVAL, CONSTRUCTION SCHEDULING AND INSTALLATION OF THE PEDESTALS OR PROVIDER-OWNED MANHOLES WITH THE SERVICE PROVIDER. NOTIFY OWNER OF ANY SCHEDULING CONFLICTS. 13. FIELD-VERIFY EXISTING INFRASTRUCTURE TO BE RECONNECTED TO NEW OR EXISTING DISTRIBUTION (PATCHPANELS, WIRING BLOCKS, ETC.). PROVIDE ADDITIONAL MATERIAL AS NECESSARY TO COMPLETE. 14. EXISTING SYSTEMS AND CONDITIONS SHOWN ON DRAWINGS FOR EXISTING BUILDINGS ARE TO BE NOTED “FOR GUIDANCEONLY.” CONTRACTOR SHALL FIELD CHECK ALL EXISTING CONDITIONS PRIOR TO BIDDING. CONTRACTOR SHALL INCLUDE IN THEIR BID AN ALLOWANCE FOR REMOVAL AND/OR RELOCATION OF EXISTING CONDUITS, CABLES, DEVICES, FIXTURES, OR OTHER EQUIPMENT AS INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTINGTECHNOLOGY SYSTEMS TO ALL OTHER WORK AS REQUIRED. 15. PROVIDE TECHNOLOGY SYSTEMS DEMOLITION REQUIRED. REFER TO ARCHITECTURAL, TECHNOLOGY SYSTEMS AND ELECTRICAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS REQUIRED TO MAINTAIN AND/ORRESTORE CONTINUITY OF SERVICE TO EXISTING DEVICES. 16. PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED CONDUIT, CABLE, J-BOXES, OUTLETS, DEVICES, AND THELIKE, COMPLETE WITH ASSOCIATED CABLING TO DISTRIBUTION LOCATION. WHERE IT IS NOT FEASIBLE TO REMOVE THE ABOVE, OUTLET SHALL BE ABANDONED, CABLE REMOVED, AND BLANK COVER PLATES PROVIDED. 17. ALL (E) EQUIPMENT BEING REMOVED SHALL BE [DISCARDED] [RECYCLED] IN ACCORDANCE WITH APPLICABLE EPA AND LOCAL REQUIREMENTS. 18. EXISTING LIGHT FIXTURES, ELECTRICAL EQUIPMENT, ETC. BEING REMOVED SHALL BE RETURNED TO THE OWNER, EXCEPT FOR THOSE ITEMS BEING RELOCATED. 19. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN. 20. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER’S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER’S ATTENTION PRIOR TO INSTALLATION. 21. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER’S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENTCOMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED. 22. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 23. WHERE THE RE-USE OF EXISTING EQUIPMENT, CONDUITS, CABLES, AND DEVICES IS PERMISSIBLE, MAKE CERTAIN THAT THESE COMPONENTS COMPRISE A COMPLETE AND OPERABLE SYSTEM. PROVIDE ADDITIONAL MATERIAL AS NECESSARY TO (RE) ESTABLISH OPERATION. 24. WHERE EXISTING PATHWAYS (CONDUIT AND BOXES) ARE TO BE REUSED, ENSURE CABLING PASSES THROUGH NO OUTLET OR JUNCTION BOX WHICH MAY BE RENDERED INACCESSIBLE BY THE ARCHITECTURAL OR STRUCTURAL CHANGES TO BE MADE TO THE BUILDING. 25. EXISTING CONDUITS, CABLE, AND DEVICES WHICH ARE NOT INDICATED FOR REUSE SHALL BECOME THE PROPERTY OF CONTRACTOR. EQUIPMENT AND DISTRIBUTION EQUIPMENT (PATCHPANELS, WIRING BLOCKS, ETC.) SHALL BE RETURNED TO THE OWNER UNLESS OTHERWISE EXPLICITLY STATED BY OWNER IN WRITING. 26. ALL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. 27. SYSTEMS SHALL BE TESTED AND VERIFIED UPON COMPLETION OF INSTALLATION. SYSTEMS THAT DO NOT PASS INDUSTRY STANDARD TESTS SHALL BE CORRECTED AT NO ADDITIONAL COST TO OWNER. 28. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER’S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COSTTO THE OWNER. 29. PROVIDE SOLUTION-BASED EXTENDED WARRANTIES FOR STRUCTURED CABLING SYSTEMS. PROVIDE ALL NECESSARY DOCUMENTATION TO OWNER PRIOR TURNOVER. 30. CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT RECORD DRAWINGS ON-SITE WHICH SHALL BE AVAILABLE FOR REVIEW DURING ENGINEER’S SITE OBSERVATIONS. UPON COMPLETION, PROVIDE OFFICIAL SET OF RECORD DRAWINGS TO ARCHITECT, IN FORMAT AS REQUESTED BY OWNER. DRAWINGS SHALL INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS,FIELD ALTERATIONS, REROUTINGS, ETC. 31. CONDUITS FOR TECHNOLOGY SYSTEMS LARGER THAN TRADE SIZE 1 (1”) SHALL HAVE LONG-RADIUS SWEEPS AT ALL CHANGES IN DIRECTION. LONG-RADIUS SWEEPS SHALL BE MINIMUM 12X CONDUIT DIAMETER. 32. OUTLET BOXES SHALL BE MINIMUM 4-11/16”x4-11/16”x2-1/2”, METALLIC OR NONMETALLIC AS PROJECT REQUIREMENTS DICTATE. 33. FLEXIBLE METAL CONDUIT SHALL NOT BE USED AS CABLE PATHWAY. ONLY SMOOTH-WALLED METALLIC CONDUIT OR TUBINGMAY BE USED. ALTERNATELY, PLASTIC-TYPE (ENT AND/OR PVC) TUBING MAY BE USED. 34. ALL METALLIC SUPPORT COMPONENTS (CONDUITS, SLEEVES, PATHWAYS, CABLETRAY, J-HOOKS OR OTHER SUPPORT, RACKS, CABINETS, ETC.) SHALL BE BONDED WITH NO SMALLER THAN #6AWG INSULATED (GREEN) COPPER BONDING CONDUCTORS. ALL COMPONENTS SHALL BE BONDED TO TELECOMMUNICATIONS GROUNDING BUS. REFERENCE DRAWINGS AND ANSI J-STD-607-ASTANDARD. 35. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A NYLON PULLTAPE INSTALLED. PULLTAPE SHALL HAVE PHYSICAL LENGTHMARKINGS AND BE RATED FOR 200-LB STRENGTH. EMPTY PATHWAYS SHALL BE IDENTIFIED AS SUCH AT ALL JUNCTION BOXES, PULLBOXES, AND OUTLET/DEVICE BOXES, USING PERMANENT LABELING. LABELING TAG SHALL INDICATE INTENDED USE OF CONDUIT, LOCATION OF PATHWAY ORIGINATION, AND LOCATION OF TERMINATION OF EACH INDIVIDUAL CONDUIT. 36. ALL CABLING SHALL BE INDEPENDENTLY SUPPORTED FROM STRUCTURAL ELEMENTS. CABLING IS NOT ALLOWED TO COME INCONTACT WITH PIPING, ELECTRICAL CIRCUITS/CONDUITS, LIGHTING FIXTURES, DUCTWORK, OR ANY OTHER INSTALLED SYSTEM. CABLING SHALL NOT USE STRUCTURAL MEMBERS ALONE AS SUPPORT; APPROPRIATE J-HOOKS, BRIDLE RINGS, OR SIMILAR SHALL BE USED. CABLING SHALL BE INSTALLED WITH SUPPORTS NO GREATER THAN 5’-0” SPACING. 37. ALL EQUIPMENT SHALL BE INDEPENDENTLY SUPPORTED FROM STRUCTURAL ELEMENTS. 38. PROVIDE PULLBOXES ALONG CONDUIT RUNS AT 100 FEET INTERVALS OR EVERY 180-DEGREES OF BENDS, OR BOTH. 39. CONDUITS MAY NOT CHANGE DIRECTION MORE THAN 90 DEGREES AT ANY SINGLE BEND. 40. CONDULETTE FITTINGS MAY NOT BE USED TO CHANGE PATHWAY DIRECTION AT ANY TIME. 10/16/18 3.7 4 4.4 5 5.44.2 A10 A11 A12 A13 A9.9 C W W 1 4 3 3 3 3 3 3 5 2 5 5 5 3.7 4 4.4 5 5.4 4.2 A10 A11 A12 A13 A9.9 BEDROOM A3-05 BEDROOM A3-13 BEDROOM A3-23 LIVING ROOM A3-24 BATH 02 A3-26 HALL A3-27 CLOSET A3-25 BATH 01 A3-20 HALL A3-21 CLOSET A3-22 BATH A3-10 HALL A3-11 CLOSET A3-12 HALL 01 A3-01 HALL A3-02 CLOSET A3-04 BATH A3-03 W W TV TV TV TV TV ALBUQUERQUE | AVON | DENVER| FORT COLLINS 303.278.3820 www.bgbuildingworks.com Project No. 8203.02 Copyright 2018 PROJ. NO. DRAWN: CHECKED: DATE: © BG BUILDINGWORKS SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ®9/12/2018 4:04:26 PM C:\Users\eng-keh\Documents\820302_FourSeasonsVail_mept17_eng-keh.rvt 1/4" = 1'-0"FOUR SEASONS RESORT AT VAILONE VAIL ROADVAIL, CO 81657116194.00 KEH ETA 09/12/2018 PERMIT UNIT 3101 TECHNOLOGY PLAN T3-03 FOUR SEASONS RESORT AT VAIL ELR SCALE: 1/4" = 1'-0"1 UNIT 3101 TECHNOLOGY DEMOLITION PLAN SCALE: 1/4" = 1'-0"2 UNIT 3101 TECHNOLOGY PLAN NOTES: 1. PROVIDE CONDUIT SLEEVES THROUGH WALLS TO STRUCTURE TO FACILIATE CABLING. PROVIDE FIRE-RATED PATHWAYS WHERE REQUIRED. 2. ALL LOW VOLTAGE CONDUIT STUBBED OUT ABOVE FINISHED CEILINGS SHALL HAVE LONG RADIUS SWEEPS. 3. CABLE TIES SHALL BE RELEASABLE AND COMPOSED OF HOOK AND LOOP, RUBBER, OR SOFT POLYMER. ZIP-TIES OR EQUAL SHALL NOT BE USED. 4. ROUTE ALL CABLING NOT IN CONDUIT VIA J- HOOKS, ARLINGTON LOOPS OR SLINGS SUSPENDED FROM STRUCTURE. CABLING SHALL NOT RUN UNSUPPOIRTED FOR LENGTHS GREATER THAN 5'-0". 5. ALL VOICE/DATA CABLING SHALL BE HOMERUN TO THE NEAREST SERVING TR/IDF AND TERMINATED ON RACK MOUNTED PATCH PANELS. 6. ALL (N) VOICE/DATA OUTLETS SHALL RECEIVE 4-11/16" x 4-11/16" X 2-1/8" OUTLET BOXES. PROVIDE A 1-GANG MUDRING FOR EACH. 7. ALL INFRASTRUCTURE SUPPORTING VOICE/DATA STRUCTURED CABLING SYSTEMS (RACKING, GROUNDING, PATHWAYS, ETC.) SHALL MEET BICSI STANDARDS. 8. CONTRACTOR TO PROVIDE BLOCKING AT ALL WALL MOUNT TV LOCATIONS TO SUPPORT 75 LBS. DEMO NOTES: 1. DEMOLITION PLAN INDICATES A DESIRED SCOPE OF WORK; THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY IN FIELD PRIOR TO START OF WORK. 2. CONDITIONS MAY EXIST WHERE (E) CABLING AND/OR EQUIPMENT IS INSTALLED WIHTIN AREA OF DEMOLITION THAT IS INTENDED TO REMAIN IN ORDER TO KEEP SYSTEMS OUTSIDE THE AREA OF DEMOLITION IN OPERABLE CONDITION. 3. CONTRACTOR SHALL PROVIDE APPROPRIATE PROTECTION AND EXERCISE CARE WHEN PERFORMING DEMOLITION AROUND SUCH CABLING AND EQUIPMENT. 4. ALL SYSTEMS LOCATED OUTSIDE THE AREA OF DEMOLITION ARE INTENDED TO REMAIN OPERABLE. 5. OWNER TO REMOVE ALL AUDIOVISUAL AND NETWORKING EQUIPMENT PRIOR TO DEMOLITION. 6. CONTRACTOR SHALL COORDINATE WITH OWNER AND ENSURE ALL EQUIPMENT TO BE RETAINED BY OWNER HAS BEEN REMOVED PRIOR TO DEMOLITION WORK. 7. ALL (E) FACEPLATES ON VOICE/DATA AND AUDIOVISUAL WALL PLATES SHALL BE REMOVED AND REPLACED WITH NEW. # DEMO NOTES: 1 REMOVE COMMUNICATIONS FACEPLATE, OUTLET BOX, AND PATHWAYS IN THEIR ENTIRETY. BACK PULL CABLING AND COIL ABOVE CEILNG FOR POSSIBLE REUSE. IF ANY CABLING IS DEEMED TO BE IN POOR OR UNUSABLE CONDITION OR IF CABLING LENGTH IS DEEMED INSUFFICIENT FOR REUSE, REMOVE IN ITS ENTIRETY. 2 REMOVE COMMUNICATIONS/AUDIOVISUAL INFRASTRUCTURE AND CABLING IN ITS ENTIRETY. 3 COMMUNICATIONS INFRASTRUCTURE AND CABLING TO REMAIN. REMOVE (E) FACEPLATE AND REPLACE WITH NEW. 4 COMMUNICATIONS/AUDIOVISUAL INFRASTRUCTURE TO REMAIN. BACKPULL EXISTING COMMUNICATIONS CABLING AND COIL ABOVE CEILING FOR POSSIBLE REUSE. REMOVE (E) AUDIOVISUAL CABLING. REMOVE (E) FACEPLATE AND REPLACE WITH BLANK COVER. 5 REMOVE EXISTING LOUDSPEAKERS AND CABLING. 10/16/18