HomeMy WebLinkAboutB18-0459_approved plans_1539984247.pdf1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
A0.00
COVERVILLAGE CENTER UNIT 1-BProject Number - 1858126 WILLOW BRIDGE RD 1BVAIL, CO 8165709/07/2018
PERMIT
OWNER: GALIONE, THOMAS J.
ARCHITECT: BILL PIERCE, PRINCIPAL IN CHARGE
PIERCE ARCHITECTS
1650 E. VAIL VALLEY DRIVE, C1
VAIL, COLORADO 81657
P: 970.476.6342
F: 970.476.4901
E: bill@vailarchitects.com
CONSULTANTS:
CONTRACTOR:
P:
M:
E:
STRUCTURAL ENGINEER:
P:
E:
OWNER'S REP
ADMINISTRATIVE INFO.
BUILDING CODE SUMMARY
PROJECT DIRECTORY
BUILDING CODE: 2015 IBC
CONSTRUCTION TYPE:
DWELLING UNITS:
OCCUPANCY TYPE R-2
LEGAL DESCRIPTION OF PROPERTY:
Situs Address - 000126 WILLOW BRIDGE RD #1B
VAIL COLORADO 81657
Tax Area - 000126 WILLOW BRIDGE RD #1B
Parcel Number - 2101-082-09-005
Legal Summary Section: DESC: BLDG A PK SP 24 Subdivision: VILLAGE
CENTER Unit: 1B BK-0704 PG-0143 WD 08-15-96
R742447 DEC 10-26-00
R742448 DEC 10-26-00
R200602882 DEC 02-03-06
R200625849 MAP 09-22-06
126 WILLOW BRIDGE RD 1B
VAIL, CO 81657
PROJECT LOCATION
DATE NO. DESCRIPTION
10/19/18
5/8" GYPSUM
WALL BOARD
3 1/2"
W4-4
2X4 DIMENSIONAL LUMBER
@ 16" O.C., SEE PLANS AND
WALL TAG FOR LUMBER SIZE, TYP.
SOUND BATTS
GENERAL ASSEMBLY AND FINISH SYSTEMS
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not
limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any
discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance
with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product.
Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over
architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location
dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to
installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following
assembly narratives are general.
WALL SYSTEMS:
CEILING SYSTEMS:
FLOOR SYSTEMS:
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies
prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both
architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound
and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general.
NOTES
* Stone veneer to be installed in strict conformance with ESR Reports (ICC) for manufacturer selected.
Comply with the Rocky Mountain Masonry Institute requirements & specifications for systems not
evaluated by ICC, 2009 International Building Code requirements and industry recognized trade
standards.
** Interior Walls Studs:
4 - 2x4 Wood Studs
6 - 2x6 Wood Studs
8 - 2x8 Wood Studs
RE: See wall tags for stud sizes.
**** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture
resistant
non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant
non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where
recommended by manufacturer. Maintain required fire-rating.
Refer to Structural Drawings for Bearing Walls and Shear Walls.
RATED ASSEMBLIES (EXTERIOR): N/A
RATED ASSEMBLIES (EXTERIOR): N/A
NON-RATED ASSEMBLIES (INTERIOR):
W4-*** GYPSUM BOARD PARTITION ON 2 x WOOD STUDS
(Non-Rated)
(1) Layer 5/8" gypsum board**** on each side of 2x wood studs at non-bearing walls demising bedrooms
and living areas. Sound batt insulation. (Re. Structural for size and spacing).
ROOF SYSTEMS:
WALL ASSEMBLIES
EXTERIOR WALL ASSEMBLIES:
INTERIOR WALL ASSEMBLIES:
NOTE: ALL EXTERIOR WALLS TO HAVE A FIRE RATING OF 1
HOUR MINIMUM. STRUCTURE TO HAVE FIRE SPRINKLER
SYSTEM.
NON-RATED ASSEMBLIES @ FOUNDATION WALLS:
EXISTING STRUCTURE
BLOCKING AS NEEDED
TENTED RECESSED
CAN LIGHT BY OTHERS
5/8" GYP. CEILING
REQ. INSULATION BY OTHERS
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
A0.21
ASSEMBLIESVILLAGE CENTER UNIT 1-BProject Number - 1858126 WILLOW BRIDGE RD 1BVAIL, CO 8165709/07/2018
PERMIT
1 1/2" = 1'-0"1 INTERIOR PARTITION (2X4) W4-4
DATE NO. DESCRIPTION
1 1/2" = 1'-0"2 R4 RECESSED CAN LIGHT
10/19/18
8'-1" 7'-10"4'-11"3'-0"3'-0" UNIT 1B UNIT 1A
DINING
KITCHEN
LIVING
BEDROOM
BEDROOM
BEDROOM
BATH MECHANICAL
BEDROOM
BEDROOM
KITCHEN
LIVING DINING
STAIR STAIR
A1.01
2
7'-10"3'-0"4'-11"8'-1" 3'-0" BENCHBENCH SHELVINGCABINETSHELVINGCABINETBARN DOOR2468BARN DOOR2468SHOWER HEAD GLASS SCREENGLASS SCREEN SB25 2DB12 2DB24 2DB19 2DB12 SB24SHOWER VALUES SHOWER VALUESW4-4
W4-4
W4-4
R4
R4
R4
R4
R4
R4
R4
R4 EXHAUST FAN W/ FIRE DAMPEREXHAUST FAN W/ FIRE DAMPER NEW WALLS
EXISTING WALLS
WALL LEGEND
RECESSED FIXTURE
(TYPE R4)
RCP LEGEND
SINGLE SWITCH
D
3
DIMMER SWITCH
3-WAY
SWITCH
DJ
DOOR JAMB
SWITCH
J JUNCTION BOX
M MOTION SENSOR
4
LUTRON 6 SLOT
SWITCH
6
VENT FAN LIGHT
CMD
CARBON
MONOXIDE
DETECTOR
SD SMOKE
DETECTOR
4-WAY SWITCH
M LUTRON MOTION
SWITCH
POP UP OUTLETP
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
A1.01
BATH
REMODELVILLAGE CENTER UNIT 1-BProject Number - 1858126 WILLOW BRIDGE RD 1BVAIL, CO 8165709/07/2018
PERMIT
1/4" = 1'-0"1 LEVEL 1
3/4" = 1'-0"2 BATH ENLARGED
3/4" = 1'-0"3 BATH CEILING PLAN
DATE NO. DESCRIPTION
Maintain fire seperation wall with 5/8th x gyp
Rated can enclosures per
attached detail
Bath fans to terminate at existing
terminations or DRB approval
will be required for new
terminations
Provide smoke and CO detectors throughout existing
10/19/18