Loading...
HomeMy WebLinkAboutB18-0459_approved plans_1539984247.pdf1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.00 COVERVILLAGE CENTER UNIT 1-BProject Number - 1858126 WILLOW BRIDGE RD 1BVAIL, CO 8165709/07/2018 PERMIT OWNER: GALIONE, THOMAS J. ARCHITECT: BILL PIERCE, PRINCIPAL IN CHARGE PIERCE ARCHITECTS 1650 E. VAIL VALLEY DRIVE, C1 VAIL, COLORADO 81657 P: 970.476.6342 F: 970.476.4901 E: bill@vailarchitects.com CONSULTANTS: CONTRACTOR: P: M: E: STRUCTURAL ENGINEER: P: E: OWNER'S REP ADMINISTRATIVE INFO. BUILDING CODE SUMMARY PROJECT DIRECTORY BUILDING CODE: 2015 IBC CONSTRUCTION TYPE: DWELLING UNITS: OCCUPANCY TYPE R-2 LEGAL DESCRIPTION OF PROPERTY: Situs Address - 000126 WILLOW BRIDGE RD #1B VAIL COLORADO 81657 Tax Area - 000126 WILLOW BRIDGE RD #1B Parcel Number - 2101-082-09-005 Legal Summary Section: DESC: BLDG A PK SP 24 Subdivision: VILLAGE CENTER Unit: 1B BK-0704 PG-0143 WD 08-15-96 R742447 DEC 10-26-00 R742448 DEC 10-26-00 R200602882 DEC 02-03-06 R200625849 MAP 09-22-06 126 WILLOW BRIDGE RD 1B VAIL, CO 81657 PROJECT LOCATION DATE NO. DESCRIPTION 10/19/18 5/8" GYPSUM WALL BOARD 3 1/2" W4-4 2X4 DIMENSIONAL LUMBER @ 16" O.C., SEE PLANS AND WALL TAG FOR LUMBER SIZE, TYP. SOUND BATTS GENERAL ASSEMBLY AND FINISH SYSTEMS Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general. WALL SYSTEMS: CEILING SYSTEMS: FLOOR SYSTEMS: Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general. NOTES * Stone veneer to be installed in strict conformance with ESR Reports (ICC) for manufacturer selected. Comply with the Rocky Mountain Masonry Institute requirements & specifications for systems not evaluated by ICC, 2009 International Building Code requirements and industry recognized trade standards. ** Interior Walls Studs: 4 - 2x4 Wood Studs 6 - 2x6 Wood Studs 8 - 2x8 Wood Studs RE: See wall tags for stud sizes. **** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistant non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where recommended by manufacturer. Maintain required fire-rating. Refer to Structural Drawings for Bearing Walls and Shear Walls. RATED ASSEMBLIES (EXTERIOR): N/A RATED ASSEMBLIES (EXTERIOR): N/A NON-RATED ASSEMBLIES (INTERIOR): W4-*** GYPSUM BOARD PARTITION ON 2 x WOOD STUDS (Non-Rated) (1) Layer 5/8" gypsum board**** on each side of 2x wood studs at non-bearing walls demising bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing). ROOF SYSTEMS: WALL ASSEMBLIES EXTERIOR WALL ASSEMBLIES: INTERIOR WALL ASSEMBLIES: NOTE: ALL EXTERIOR WALLS TO HAVE A FIRE RATING OF 1 HOUR MINIMUM. STRUCTURE TO HAVE FIRE SPRINKLER SYSTEM. NON-RATED ASSEMBLIES @ FOUNDATION WALLS: EXISTING STRUCTURE BLOCKING AS NEEDED TENTED RECESSED CAN LIGHT BY OTHERS 5/8" GYP. CEILING REQ. INSULATION BY OTHERS 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.21 ASSEMBLIESVILLAGE CENTER UNIT 1-BProject Number - 1858126 WILLOW BRIDGE RD 1BVAIL, CO 8165709/07/2018 PERMIT 1 1/2" = 1'-0"1 INTERIOR PARTITION (2X4) W4-4 DATE NO. DESCRIPTION 1 1/2" = 1'-0"2 R4 RECESSED CAN LIGHT 10/19/18 8'-1" 7'-10"4'-11"3'-0"3'-0" UNIT 1B UNIT 1A DINING KITCHEN LIVING BEDROOM BEDROOM BEDROOM BATH MECHANICAL BEDROOM BEDROOM KITCHEN LIVING DINING STAIR STAIR A1.01 2 7'-10"3'-0"4'-11"8'-1" 3'-0" BENCHBENCH SHELVINGCABINETSHELVINGCABINETBARN DOOR2468BARN DOOR2468SHOWER HEAD GLASS SCREENGLASS SCREEN SB25 2DB12 2DB24 2DB19 2DB12 SB24SHOWER VALUES SHOWER VALUESW4-4 W4-4 W4-4 R4 R4 R4 R4 R4 R4 R4 R4 EXHAUST FAN W/ FIRE DAMPEREXHAUST FAN W/ FIRE DAMPER NEW WALLS EXISTING WALLS WALL LEGEND RECESSED FIXTURE (TYPE R4) RCP LEGEND SINGLE SWITCH D 3 DIMMER SWITCH 3-WAY SWITCH DJ DOOR JAMB SWITCH J JUNCTION BOX M MOTION SENSOR 4 LUTRON 6 SLOT SWITCH 6 VENT FAN LIGHT CMD CARBON MONOXIDE DETECTOR SD SMOKE DETECTOR 4-WAY SWITCH M LUTRON MOTION SWITCH POP UP OUTLETP 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A1.01 BATH REMODELVILLAGE CENTER UNIT 1-BProject Number - 1858126 WILLOW BRIDGE RD 1BVAIL, CO 8165709/07/2018 PERMIT 1/4" = 1'-0"1 LEVEL 1 3/4" = 1'-0"2 BATH ENLARGED 3/4" = 1'-0"3 BATH CEILING PLAN DATE NO. DESCRIPTION Maintain fire seperation wall with 5/8th x gyp Rated can enclosures per attached detail Bath fans to terminate at existing terminations or DRB approval will be required for new terminations Provide smoke and CO detectors throughout existing 10/19/18