10 cIF P4 SPECIFICATIONS: MECHANICAL AND ELECTRICALSYSTEMS LEGEND ISSUE LOG X44 / / POWER SYMBOLS PIPING DESIGNATIONS DUCTWORK LEGEND SHEET INDEX / 10/22118 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIORTO COMMENCEMENT OF WORK. / // /// SINGLE LINE DESCRIPTION DOUBLE LINE �� / / / 2. REVIEW ARCHITECTURAL,STRUCTURAL, MECHANICAL,AND OTHER DRAWINGS PRIOR TO BID. e- SINGLE RECEPTACLE 0 HYDRONIC PIPING 0 / / 3. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. & DUPLEX RECEPTACLE -HWS- HEATING WATER SUPPLY 90° ELBOW DOWN(ROUND DUCT ONLY) MED �� C� DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER -HWR- HEATING WATER RETURN # TITLE ��� 4. Subcontractors shall be responsible to notify the prime contractor of discrepancies or conflicts in the construction documents found during bidding and/or prior to performing / the work. & DOUBLE DUPLEX RECEPTACLE 4�// PLUMBING PIPING ROUND 90° ELBOW UP (ROUND DUCT ONLY) 7 ME-0.0 MECHANICAL/ELECTRICAL LEGEND AND SPECIFICATIONS 'I 5. WORK,MATERIALS,AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL,STATE OF COLORADO,AND NATIONAL CODES AND OW GFCI DUPLEX RECEPTACLE - D - DRAIN PIPE ORDINANCES. DUPLEX RECEPTACLE; HALF SWITCHED -RS- REFRIGERANT SUCTION D OFFSET TO CHANGE ELEVATION D ME-1.1 MECHANICAL/ELECTRICAL LEVEL ONE FLOOR PLANS J 6. PROVIDE PERMITS AND INSPECTIONS REQUIRED. (AT 30°WHEN POSSIBLE) • ) ME-1.2 MECHANICAL/ELECTRICAL LEVELS TWO PLANS 'I Z o ISOLATED GROUND DUPLEX RECEPTACLE -RL- REFRIGERANT LIQUID 2 I 12 D=DROP R=RISE ( I I• U 7. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONEp Y YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. ® MULTI OUTLET PLUG STRIP r0'e ROUND RADIUS ELBOW 0 ._ - U ry 8. SYSTEMS SHALL BE COMPLETE,OPERABLE,AND READY FOR CONTINUOUS OPERATION. ® FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE PLAN SYMBOLS O g ® FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE 00 9. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION G CONTROL PANEL/RADIANT MANIFOLD a, Z Z 90°STRAIGHT TEEfilZ REQUIRED. CONTRACTORSHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS AS REQUIRED ® FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED _ - > 3 ®O CARBON DIOXIDE SENSOR Z 3 TO MAINTAIN AND/OR RESTORE CONTINUITY OF EXISTING SYSTEMS. ID en w 3 El FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM 9 CARBON MONOXIDE SENSOR ) ) 1 - E 10. PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT. WALL MOUNTED SPECIAL OUTLET AS NOTED 0 HUMIDISTAT C I C 90°CONICAL TEE ( w 0 m Q 11. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ® SPECIAL OUTLET AS NOTED 0 REMOTE TEMPERATURE SENSOR nn�� - ARCHITECT/ENGINEER'S ATTENTION PRIORTO INSTALLATION. ISSUE LOG K EY: V >. w 0 JUNCTION BOX 0 THERMOSTAT 45° BRANCH 12. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE,CONTRACTOR SHALL MAK ECORRECTIONS '-\I' ISSUED AS PART OFA SET H co NECESSARY AT NO COST TO OWNER. a SP DUCT STATIC PRESSURE SENSOR W o w r> J WALL MOUNTED JUNCTION BOX NOT PART OF SET H N w P ROOM PRESSURE SENSOR *' ISSUED FOR INFORMATION ONLY QAlgi O N 13. WIRE SHALL BE COPPER,75 DEGREE CELSIUS RATED FOR GENERAL USE. FOR HID FIXTURES AND WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS O FLOOR MOUNTED JUNCTION BOX Z Z 45°CONICAL TEE 0 o m M WIRE SHALL BE COPPER,MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT. e © EMERGENCY POWER OFF SWITCH Q o DIVISION 15 EQUIPMENT POWER CONNECTION CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. 600 VOLT ALUMINUM WIRE AND CABLE IN SIZES 1/0 AND LARGER MAY e PLUMBING/HVAC RISER BE SUBSTITUTED FOR COPPER ON SERVICES AND FEEDERS IF AMPACITY IS EQUAL TO OR GREATER THAN COPPER,AND VOLTAGE DROP IS EQUAL TO OR D TIMER SWITCH SIZE OR SHAPE TRANSITION jr LESS THAN COPPER AND SHALL BE TERMINATED AT SWITCHES,LUGS, CIRCUIT BREAKERS, ETC.,WITH MAC-ADAPT SERIES"MPT"MACHINE COMPRESSION DIAGRAM CONTINUATION REFERENCE Jr, EXISTING SA ADAPTERS OR EQUAL. FUSED DISCONNECT EXI TIVS NG=A SECTION CUT LETTER/SHEET SHOWN ON 14. CONTRACTORSHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS DI NON FUSED DISCONNECT ROUND FLEXIBLE DUCT :�:�:�:�:�:�:�:' WI POINT OF DISCONNECTION M;,.,.,.,, SECTION,OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. ® MOTOR STARTER 0 POINT OF NEW CONNECTION BALANCE DAMPER,- 1----1-..- � - 15. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L.OR OTHER RECOGNIZED TESTING FACILITY. ® ENCLOSED CIRCUIT BREAKER EA] ACCESS PANEL © TYPICAL. / \ 90°ELBOW DN(NEGATIVE PRESSURE) i 16. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT BREAKERS, SAFETY SWITCHES,AND ALL OTHER ELECTRICAL APPARATUS SHALL BE LISTED ® PULL BOX ` SNOWMELT MANIFOLD t 1 AS SUITABLE FOR 75 DEGREE CELSIUS. p. PUSH BUTTON 17. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES,AND 15 AMPERES FOR DUPLEX RECEPTACLES. THE z Ex 90°ELBOW DN(POSITIVE PRESSURE) Jr j x/ FLEX CONNECTION,TYP. COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT. D TIME CLOCK A I R DEVICE DESIGNATION K EY V PHOTO-CELL CONDENSATE DRAIN W/ TRAP.PIPE 18. DEVICES SHALL BE AS FOLLOWS: Z-0 90°ELBOW UP(NEGATIVE PRESSURE) CONNECT EXISTING RA AND INDIRECT TO FLOOR DRAIN. ❑ T TRANSFORMER SA TO NEW FAN COIL. FAN COIL A. RECEPTACLES-HUBBELL NUMBER 5262 SERIES G PANELBOARD OR LOADCENTER TYPE OF AIR DEVICE UNIT B. SWITCHES-HUBBELL NUMBER 1221 SERIESRE:GRD SCHEDULE. Z-B 90° ELBOW UP(POSITIVE PRESSURE) D C CONTACTOR +=i1 C. COVER PLATES SHALL BE SMOOTH THERMOPLASTIC,COLOR AS SELECTED BY ARCHITECT. PROVIDE COVER PLATES FOR SWITCHES,RECEPTACLES, n ELECTRIC MOTOR # = AIR QUANTITY(CFM) OSA DUCT. lrD� TELEPHONE,TELEVISION,COMPUTER,AND J-BOX OUTLETS AS REQUIRED. CONNECT TO CA = COMBUSTION AIR 90° RADIUS ELBOW =r)). FILTER W/ACCESS PANEL. g METER EXH = EXHAUST EXISTING. 19. FIXTURES RECESSED IN"T-BAR"CEILING SHALL BE SUPPORTED INDEPENDENTLY OF CEILING SYSTEM,WITH FOUR NUMBER 12 HANGER WIRES UP TO OSA = OUTSIDE AIR STRUCTURE. SECURE HANGER WIRES TO CORNERS OF FIXTURE. CLIP FIXTURE TO GRID ON TWO SIDES WITH FACTORY-FURNISHED CLIPS. FINAL 0 THERMOSTAT 150 RA = RETURN RETURN PLENUM FULL SIZE OF UNIT CONNECTION TO FIXTURE SHALL BE MADE WITH A FLEXIBLE U.L.APPROVED ASSEMBLY. 12x6 XFR = TRANSFER 90° RADIUS ELBOW W/TURNING VANES I �� INLET. ATS AUTOMATIC TRANSFER SWITCH 20. ALL DUCTWORK,DIFFUSERS,PIPING, FIXTURES,AND EQUIPMENT SHOWN IN LIGHT LINE WEIGHT IS EXISTING,NEW INDICATED BY HEAVIER LINE WEIGHT, PROVIDE MAL AETO EXCEPT WHERE NOTED. PIPES,DUCTWORK,EQUIPMENT,ETC.TO BE REMOVED,ARE SHOWN HATCHED. CIRCUIT HOMERUN SIZE (INCHES)OR MINIMUM ,...._,_.+ I I I I SUPPORT UNITETOFF FRFLMOOR CONDUIT RUN FREE AREA REQUIRED IN SQUARE DUCT SPLIT AND TO ALLOW FOR 21. OFFSET PIPING, DUCTWORK,ETC.AS NECESSARY TO ACCOMMODATE STRUCTURE,BEAMS,AND COLUMNS,AND EXISTING EQUIPMENT. SQUARE FEET. DUCTING. CONDUIT RUN BELOW GRADEV E R T I CA L FAN COIL UNIT D IA GA M XFR 22. FIRE STOPPING REQUIREMENT. PENETRATIONSTHROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH A MATERIALCAPABLEOF PREVENTING `--'•7 THE PASSAGE OF FLAMES AND HOT GASSES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC FOR FIRE STOPS ASTM-E-814. -0 CONDUIT UP ROUND DUCT SPLIT + i ACCEPTABLE MATERIALS INCLUDE: DOW CORNING RTV FIRE STOP FOAM FOR BARE PIPE,METAL CONDUIT,AND ELECTRICAL CABLE;3M FIRE DAM 150 NO SCALE CAULK FOR BARE PIPE,METAL CONDUIT,AND BUILDING CONSTRUCTION GAPS;3M CP-25 CAULK AND FS-195 INTUMESCENT STRIPS FOR INSULATED PIPES, CONDUIT DOWN PLASTIC PIPE OR CONDUIT,AND ELECTRICAL CABLE. SUBMIT UL LISTED APPLICATION DATA FOR EACH TYPE OF PENETRATION ENCOUNTERED. INDICATES AIRr SPLIT BRANCH TAKE-OFF WITH SQUARE S SWITCH ('- Jam(, 23. DUCTWORK: T . tiji INLET DEVICE. ELBOW&SPLITTER DAMPER S THERMAL OVERLOAD SWITCH - - FILTER-DRYER. A. FLEXIBLE DUCTWORK SHALL HAVE AN OUTER JACK ETOF FIRE RETARDANT POLYETHYLENE VAPOR BARRIER MATERIAL, UNIFORM LAYER OF SV VARIABLE SPEED SWITCH SPLIT BRANCH TAKE-OFF WITH RADIUSA FIBERGLASS INSULATION,HIGH-STRENGTH GALVANIZED STEEL HELIX ENCAPSULATED IN REINFORCED"RIP STOP"ALUMINUM LAMINATE INTERIOR TELBOW&SPLITTER DAMPER + w CORE,UL LISTED AND LABELED,CLASS 1 AIR DUCT. WORK INGPRESSURE RATING: POSITIVE 6", NEGATIVE 4". FLEXMASTER TYPE 5 OR SK K EYSWITCH NOTE: (� SIGHT GLASS. EQUIVALENT. SUBMIT SAMPLES TO DETERMINE EQUIVALENCE. FOR STANDARD MODULE SIZE REGISTERS,SIZE GIVEN IS NECK SIZE. REFER TO GRD SCHEDULE FOR MODULE SIZE. POSITIVE PRESSURE RISER, X X B. FLEXIBLE CONNECTION: EQUIVALENT TO VENTFAB,FIREPROOF GLASS CLOTH, 10"W.C.RATED. BTYPICALLY SUPPLY 8 SOLENOID ONE-LINE DIAGRAM SYMBOLS VALVE. TO C. ROUND DUCT: SPIRAL SEAM,GALVANIZED STEEL. DIE STAMPED OR 5 GORE ELBOWS. "SNAP-LOCK", LONGITUDINAL SEAM DUCT,OR ADJUSTABLE FITTINGS ARE ACCEPTABLE ON INDIVIDUAL GRILLE/DIFFUSER RUNOUTS ONLY. -%••••- DISCONNECT SWITCH NOTES NEGATIVE PRESSURE RISER,TYPICALLY _ z ti 0 RETURN,EXHAUST OR OUTSIDE AIR 0 EXPANSION-\ D. DUCTWORK: G60 GALVANIZED SHEET STEEL;LOCK FORMING QUALITY;CONSTRUCTED TO THE LATEST EDITION OF SMACNA"HVAC DUCT ® FUSE VALVE. w 1. ALL SYMBOLS,ABBREVIATIONS,AND DESIGNATIONS --ti-- 2 G CONSTRUCTION STANDARDS";+/-1"WC PRESSURE CLASSIFICATION,SEAL CLASS"C";WITH GALVANIZED STEEL fL CIRCUIT BREAKER ON LEGEND SHEET ARE NOT NECESSARILY USED ON G FASTENERS,ANCHORS,ANGLES,STRAPS,ETC. THIS PROJECT. I A F/S COMBINATION FIRE&SMOKE DAMPER A F/S • W CURRENT TRANSFORMER �- Q �.J 1 O E. SEAL ALL SEAMS(LONGITUDINAL AND TRANSVERSE)AIRTIGHT WITH UNITED MCGILL"UNI-GRIP"UL LISTED,WATER BASED,NON-HARDENING,ELASTIC 2. THIS DRAWING SET CONSISTS OF DATA GENERATED,IN -may-- SEALANT OR EQUIVALENT. TAPE NOT ALLOWED. -3E POTENTIAL TRANSFORMER PART,BY OTHER PARTIES.NOT ALL SYMBOLOGIES AND DX < 0 0 METER NOTATION CONVENTIONS OCCURRING IN THIS ® FIRE DAMPER ® COOLING < J Q 24. DUCTWORK NOTES: DRAWING SET ARE NECESSARILY DEFINED ON THESE --1,- COILlil Lil ELr: 0 VOLT-METER LEGENDS.CONSULT THE ENGINEER IN THE EVENT --V- Ill A. DIFFUSER NECK SIZE IS SAME AS FLEXIBLE DUCT SIZE. SYMBOLOGY OR NOTATION INTERPRETATION IS I0 SMOK EDAMPER 0 ( LL O O AMP-METER REQUIRED. v J B. UNLESS OTHERWISE NOTED,ALL CHANGES IN DIRECTION SHALL BE MADE WITH RADIUS ELBOWS WITH RADIUS TO CENTERLINE EQUAL TO 1.5 DUCT INSULATE. rn SPD SURGE PROTECTION DEVICE V♦ O WIDTH. ! , SELECTOR SWITCH I-a MOTOR OPERATED DAMPER(MOD) - THERMAL BULB.LOCATE 45° I ‘-' t `J C. ALL FLEXIBLE DUCTS SHALL NOT EXCEED EIGHT FEET IN LENGTH. ABOVE BOTTOM OF PIPE AS GF GROUND FAULT PROTECTION CLOSE AS POSSIBLE TO COIL 25. DUCTWORK SPECIALTIES MANUAL VOLUME DAMPER,SINGLE BLADE OUTLET. U sr SHUNT TRIP I DAMPER(SBD)FOR ROUND OR<10" TALL, j:.li _ \Q\ A MULTI-L RS. VOLUME DAMPERS: TITUS AG-35-B OPPOSED BLADE,ANEMOSTAT OR EQUAL. SEE DETAIL REGARDING REMOTE ACCESS TO VOLUME -I HNORMALLY OPEN CONTACT OPPOSED BLADE DAMPER(OBD)>10" TALL EQUALIZER LINE. 2 a / DAMPE 26. SUPPORT PIPE WITH ROD AND CLEVIS,RING HANGERS,TRAPEZE,OR CLAMPS. NO PIPE TAPE OR STRAPPING ALLOWED. ALL HANGERS SHALL BE SIZED NORMALLY CLOSED CONTACT PROJECT ALTITUDE - -BDD BACKDRAFT DAMPER BDD DX COIL PIPING DIAGRAM FOR OD OF INSULATION,IF ANY. PROTECT INSULATED LINES WITH 20 GA SHEET METAL SHIELDS AND PROVIDE CALCIUM SILICATE INSULATION INSERTS = GROUND FOR ALL INSULATED PIPING. MAINTAIN VAPOR BARRIER ON ALL COLD LINES. ISOLATE BARE COPPER LINES FROM HANGERS WITH VIBRASORB OR - 8150 FT ABOVE SEA LEVEL EQUIVALENT,COPPER COATED HANGERS ARE NOT SUFFICIENT,WRAPPING PIPE WITH TAPE NOT ACCEPTABLE. O NO SCALE COLD WATER GROUND CONNECTION m Im SMOK 27. FIRE PROTECTION DESIGN/BUILD REQUIREMENTS: I BUILDING STEEL GROUND CONNECTION A. EXTEND THE EXISTING SPRINK LERSYSTEM,RELOCATE EXISTING AND ADD NEW SPRINK LERHEADS IN ACCORDANCE WITH NFPA 13, ALL APPLICABLE 2 24x36 DUCT SIZE: FIRST NUMBER IS PLAN WIDTH, 24x36 CODES AND ORDINANCES AND PROJECT REQUIREMENTS TO COMPLETE THE NEW WORK. SECOND NUMBER IS DEPTH. B. SYSTEM SHALL BE INSTALLED COMPLETE AND OPERATIONAL, INCLUDING WATER FLOW INDICATOR,CONNECTIONS TO EXISTING ALARM,DRAIN PIPING, IDENTIFICATION SIGNS, ETC. C. WORK SHALL BE PERFORMED BY A QUALIFIED FIRE SPRINKLER INSTALLER WITH A MINIMUM OF FIVE(5)YEARS'EXPERIENCE IN SIMILAR INSTALLATIONS. D. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO AND DURING INSTALLATION. AIR COOLED CONDENSING UNIT SCHEDULE DUTY ELECTRICAL APPROX. MATCHED HOT GAS AMBIENT LOW AMB. OPER. MANUFACTURER* MARK SYSTEM BYPASS TEMP. DB CONTROL VOLT/ EER ACCESSORIES REMARKS COMPONENT (MBTUH - CAPACITY (°F) (°F) MCA PH MOCP WEIGHT & MODEL# CLG/HTG) (LBS) CD MITSUBISHI 0 CU-1 FC-1 60/66 N/A 95 -20 36 208/1 42 306 11.1 - - 0 Current Issue: PUMY-P6ONKMU1 0 ow PERMIT SET CU-2 FC-2 AND FC-3 60/66 N/A 95 -20 36 208/1 42 306 12.5 MITSUBISHI - - o PUMY-P6ONKMU1 rn co N- co o - - - - - - - - - - - - - - Issued: 0 MANUFACTURERS: PERMIT SET 10.17.2017 Z Q CARRIER, DAIK EN,TOSHIBA 0 GENERAL NOTES: Q A: CAPACITY STATED IN TONS IS AT PROJECT ALTITUDE w B: N- N 0 w FAN COIL SCHEDULE 6 Ui FAN COOLING COIL HEATING COIL 5 ESP ELECTRICAL AIR CONDITIONS AIR CONDITIONS MANUFACTURER* coLu MARK SERVICE TYPE O.S.A. E.A.T. L.A.T. FILTER ACCESSORIES REMARKS CD CFM CFM @ ` ) C) H S. (IN@ (IN WATT VOLT/ DB/WB DB/ WB MBH E.A.T. L.A.T. MBH & MODEL# 17 (°F) (°F) DB ( F) DB ( F) J D Z FC-1 OFFICE VERTICAL 1400 200 0.5 0.3 650 208/1 85 55 54 70 95 60 2" MITSUBISHI A,D - O AND DATA PVFYP54NAMU-E U J U FC-2 DATA WALL 900 N/A N/A N/A 70 208/1 95 55 30 N/A N/A N/A INTEGRA MITSUBISHI B C, D Z L PKFYP3ONKMUEZTH -0 INTEGRA MITSUBISHI U FC-3 DATA WALL 900 N/A N/A N/A 70 208/1 95 55 30 N/A N/A N/A B,C, D - g L PKFYP3ONKMUEZTH Sheet Title: o MANUFACTURERS: MECHANICAL ai * CARRIER, ENVIROTEC,MCQUAY,TRANE ti GENERAL NOTES: ELECTRICAL oo U) A: PROVIDE WALL MOUNTED THERMOSTAT COVER SHEET U B: PROVIDE BRANCH CIRCUIT CONTROLLERAS REQUIRED. Lu 3 C: PROVIDE WIRELESS REMOTE CONTROLLER FOR EACH UNIT. PROVIDE HOLDER/MOUNT ON NORTH WALL.FIELD COORDINATE LOCATION WITH STEADMAN IT 0' D_ D: PROVIDE BACNET CONTROL INTERFACE TO CONNECT TO EXISTING JCI BUILDING AUTOMATION SYSTEM. Date: 09.23.2016 C9 Designed: DAL 6 Reviewed: DAL Project No: 8739.00 PH-002 Sheet o: a_ co 0 a; CO ME-O . O Scale: As Shown 10 cIF P4 rr 4 W Ltp XOD 10/22/18 O DEMO FLAG NOTES: 1. REMOVE EXISTING AHU-14 AIR HANDLER AND ALL APPU RTENANCES. 2. EXISTING SPLIT SYSTEM AC U NIT AND ALL APPURTENANCES TO BE REMOVED. /A "0 Z E di J U 3. EXISTING SA DIFFUSERSTO REMAIN AND BE Iae — O Y RE BALANCED. O U p O H 3 rY 4. DISCONNECT EXISTING SA, RA AND OSA FROM _ Ow a EXISTING AIR HANDLER. () 0 0 ct col z . w _a 5. REMOVE EXISTING HU MIDIFIERAND ALLz APPURTENANCES. 0 cn w 3 J E D a) o CO 4, > Q N — I Iy O o co w 2 A iii 0 N- D N 02 M J 0 Q M H iI CORRIDOR 135 O ■ ■ 11 L j • — O X O O O 0J (E)24x12-SUPPLY <>0 _ „,___,__i, OFFICE WORK .-- COMPUTER 11 (E)24x12 RETURN 4O OFFICE 131 130 129 21 136 `--� O " 4 (EXIST) — ,., H iii z 1- QzL ) LEVEL 1 PARTIAL MECHANICAL/ELECTRICAL PLAN - DEMOco 12 I-1-1 Lij co SCALE: 1/4" = 1'-0" 0 U 0 < '< 0 WwD Hao _1 Cn � o I N- I U U = a 2 ' > > NNNN I H H 0 FLAG NOTES: co_,CO JCCCCCC 1. FUTU RE PARTITION WALL AND DOOR BY OTHERS. 2. EXISTING 48x30 DATA RACKS. 3. EXISTING OSA.CONNECT TO NEW SYSTEM AND C7 BALANCE TO 200 CFM. p CORRIDOR RL / 4. BALANCE EXISTING SA DIFFUSERSTO 300 CFM Current Issue: 135 I RL 0 5. BALANCE EXITING SA DIFFUSERSTO 200 CFM 2 RS I PERMIT SET co 6. BALANCE RA TO 600 CFM cocz o hl L o~0 7. BALANCE RA TO 800 CFM Q O O 4 I Issued: 0 0 Lev,-.4 r-- 8 X . WALL MOUNTED FAN COIL UNIT POWERED FROM P ASSOCIATED ROOFTOP CONDENSING U NIT. PERMITSET 10.17.2017 Z 00 Q 9. THERMOSTAT FOR FC-1. FIELD COORDINATE O __ I __J j __J a PREFERRED LOCATION WITH STEADMAN IT TEAM. H ____ I FC-1 12 11 (E)24x12 SUPPLY 16"0 ( 10. REFRIGERANT LIQU IDAND SUCTION LINE SETS I ` TO/FROM CONDENSING UNIT ON ROOF WITH CONTROL N- — T — r--� r--� r--� 16"Q1 AND POWER.ONE SET FOR FC-1,AND ONE SET FOR CD 0 O 2 I I I I 2 I , I FC-2 AND FC 3. FIELD COORDINATE ROUTING. Q OFFICE 131 WORKO11 COM29 ffrF�4x12 -RETURN I I I I I 14 O I/ 11. EXISTING SA AND RA DUCTS TO EXISTING GRDs IN IOFFICEO R3 R3 R3 — 0 STEADMAN IT SPACE. a_ 136 I - I I I -I I I L--J L--J L--J RA , 12. VERTICAL,FLOORMOUNTEDFANCOILUNITPOWERED 12 0 �I/ O O (EXIST) ' l\-- 12"0 O FROM ASSOCIATED ROOFTOP CONDENSING U NIT. 5 cIw CD Z _, \\—FC-2 J FC-3 D 0 0 o0 J J Q 0 Z O 0 2 i Sheet Title: c) I LEVEL 1 PARTIAL MECHANICAL/ELECTRICAL PLAN - NEW MECHANICAL/ CO ELECTRICAL N- 000 1 SCALE: 1/4" = 1'-0" LEVEL ONE PLANS U Lu O f 0_ Date: 09.23.2016 (9 Designed: DAL Cl) Reviewed: DAL Project No: 8739.00 PH-002 Sheet o: a_ N M ME- 1 . 1 N._ N: Scale: As Shown irkek 1./ 3g0j/0 - 10/22/18 0 FLAG NOTES: 1. REFRIGERATION AND CONTROL RISERS FOR NEW SYSTEMS.PROVID EENCLOSURE FOR PROTECTION. FIELD COORD INATEROUTING. 2. REFRIGERATION AND POWER FROM BELOW,ROUTE 0 'D z o ALONG ROOF TO EACH NEW OUTDOORHEAT PUMP i 2 UNIT. FIELD COORD INATEROUTING. [ N O Y 0 3. NEW OUTD OORCOND ENSING UNITS ON PRE-CAST o ( 4- CURB. ?� O ct cm 4. PROVIDE50A/2P,208V/1PHASE POWER TO EACH UNIT Z '~ > 3 FROM PANEL E1A. 0 H LTJ 3 J - D w O m u► - 11 >. 00i 0 H w0 co Rw M Miti ,...7 •- n N mM J O a co • • o • iz• {+ 1 fr • �- j 4 +21 -6 7/8 ' 72 '41A ' � � 30'—Ora I I I 1 I I 1 I I 1 I I ! I C.... :::_ -- ' .- _ _- ra I I ; I I E li • r 1 I 1 0, 7 r-sw" �,- REi.l nTro I 0 0 €0 0 0 0 0 0 0 g I EXISTING DOOR i i I11 [ I it j i f� i �.� i j !� j . i, 10'-11 1� " 42'-1 7/8 " 15'-0" 27'-5 VI " 42'-6 7/f! 27'-9" T — 1 !ei 1 ! MEC H,2rlf ' Z H TTTT 4TT "ff 4 2 34'x' I I I I 1 � I E r < z j I I i j i i i ,`I I ; 1 iI w Ln I i I i i t 0 I 1i ;� —. -� I - — --- Ier I, 2 k _____. I I I -l—j -�-L - I 'n i i i I it 00 _ _ - ___ ._.-_.. - O ri ! - t I 1 ' --.....- U I I I iV Q IA r r !EXISTING ! i { ,.�. � ......�, i.�..� Ct 1 i i ROQF BELOW i ; 1 , ' -,a - -- - _-----_--- - -- H 11 O a F ..._- --- -------1.-- __ SUFE DOWN 60'1: r n i i - ----r - _ I - — — I I I I EI.: 55' o` r27 iD 1 •45 I v/ 0 NEW SKYLIGHT BELOW - ; i W ROOF BELOW sTA-,...4- j�_ U 40. QIi I ' I 1 1 I • p1eILEMMI } pRDOc i i0WA I II 46, 1 G Q >1276 0 )1 , >ii::( 14.1- 1" i I is ! j \ .- 1 EQUIP.ji * 339OR +7 I i: i i I! * �� j 132:-8 . I 338 I 1 .3 + I em I • i I I I * POST j I I 1 I 14- ---------- !We moor,1 -- 1m !� -i ---------------1 `-'I�'lllill ._._ - - - - - - - 3 _..L - - . PARTUM 4 I CLEAN I r �- -E 1 T "' 1,-44-'210M1911-401.1 - - - -- - - - - - - SUPPLYi ► I Imo` _.-p_„zi m '� I I I I 235 * 265 lI L I vfr O141)WER rqi• I .,:::,5, STAFF 4> i a I SHOWER f I * . i I I - LOUNGE - WOME S ; ,a t /� *fir 1 �,a Etna a MEN'S I �� 331-� f I i I 342-8 .i" = 327 LOCKERS 14011' mi LOCKER0 } •i �` J 331 I I * I j WOMENS MEIN 326 ; 0 a 1 . ,J 3421(ER5 [ r� r J • i i �] �+ r ,RECOVERY 01 1 IL* WY ` T c—SECTION I7 mil __I____IPM �� I�� f ; x.. f (2134 4 x}. • GAS STOR. OILET j _ f 1 I ..` * • OILET • � - '� '4 - -- - _ -- i FROZEN �' � _ I 325w �, I �PATFf. CORRIDOR f f:. I CORRIDOR f I I v v 'I 41),* 328 1 I f I 337 1.1141.R.�" c*r__ �r _ f �: 330 3p I • CR1r]OR .. .� _ - - - - � °�_-.1... -a'" rte_ - - - I - - - - [x - - - 269-A , - �-� ��.^J-. • rPo r! I �` � f r.-:'rn. Ifs T� - ego. 4 FKe> �� I _ - - _ - -�- __ I . l \ -'- . _ rsi 0 Current Issue: N w PERMIT SET 0 0 CS) LEVEL 3 PARTIAL MECHANICAL/ELECTRICAL PLAN LEVEL 2 PARTIAL MECHANICAL/ELECTRICAL PLAN co o Issued: Q 2 SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" U PERMIT SET 10.17.2017 Z Q 2 0 Q w H- (n r- N 0 w CO Q I 0 (n w _U L w 6 0 Z_ H J D (n Z 00 U J J a 0 Z 0 U Sheet Title: MECHANICAL/ CO ELECTRICAL CO LEVEL TWO & w0 THREE PLANS 0 il Date: 09.23.2016 0 m Designed: DAL 6 Reviewed: DAL Project No: 8739.00 PH-002 Sheet o: o_ co of ME- 1 .2 Scale: As Shown