Loading...
HomeMy WebLinkAboutB18-0462_Approved Documents_1540914326.pdf 75 South Frontage Road Solar Thermal/Solar Electric West, TOWN OF VAIL Systems TOWN 1� 1 Vail,CO 81657 B18-0462 TO YY�A�IY OF YA1 0, Office:970.479.2139 Issued: Inspections: inspections@vailgov.com Property Information Address: 551 N FRONTAGE RDW(210106302013) (210106302013 ) Unit#: Parcel Number: 210106302013 Legal Description: RED SANDSTONE ELEMENTARY SCHOOL Contacts Contact Type:Applicant Full Name:Rich Clubine Address: PO Box 7627 Avon 103 Williams Street Minturn,CO 81645 Phone: 9703064233 Contact Type:Property Owner Full Name:EAGLE COUNTY SCHOOL DISTRICT RE-50J Address: Phone: None Contractor Contractor Type:General Company: Active Energies Solar,LLC State License#: Phone: 970-306-4233 Projectinformation Project Name:Red Sandstone Elementary 2017 Project Description: DC side of an 11.31kW grid-tied PV solar array on the Red Sandstone Parking Garage.Triphase Electric will be doing the AC connection. Fees Paid Conditions CONDITIONS UNDER WHICHPERMITS BECOME VOID: If construction is not begun within 6 months from the date permitwas issued. If more than 5 months elapses betweeninspections. If incorrectinformationis given on the application at the time the permitwas issued. Christopher Jarecki-Town of Vail Building Official NOTICE:By issuance of this Permitthe applicant agrees to complywith all Titles of the Town of Vail Code and all applicable State and Federal law.Failureto do so will void this Permit and the applicant shall forfeit all applicablefees. Mono Multi Solutions '' " Illllllllllflllllllll THE 1 11 1 .. I1 1 . �- ALLAAAx PLUS' - I ..: FRAMED 60—CELL MODULE 1 • . II ,• . I . I 60 CELLi____H H . MONOCRYSTALLINE MODULE ` 275-315W , 1 1 �� POWER OUTPUT RANGE 1 I 19.2% MAXIMUM EFFICIENCY Maximize limited space with top-end efficiency •*. •Up to 192W/m2 power density •Low thermal coefficients for greater energy production at high ON+5w operating temperatures POSITIVE POWER TOLERANCE Highly reliable due to stringent quality control Q.� •Over 30 in-house tests(UV,TC,HF,and many more) Founded in 1997,Trina Solar is the world's leading i comprehensive solutions provider for solar energy. •In-house testing goes well beyond certification requirements we believe close cooperation with our partners is •PID resistant critical to success.Trina Solar now distributes its •100%EL double inspection PV products to over 60 countries all over the world.Trina is able to provide exceptional service • Selective emitter,advanced surface texturing to each customer in each market and supplement our innovative,reliable products with the backing of Trina as a strong,bankable partner.We are committed to building strategic,mutually Certified to withstand the most challenging beneficial collaboration with installers,developers, environmental conditions distributors and other partners. •2400 Pa wind load •5400 Pa snow load Comprehensive Products •35mm hail stones at 97 km/h And System Certificates IEC61215/IEC61730/UL1703/IEC61701/IEC62716 ISO 9001:Quality Management System 15014001:Environmental Management System IS014064:Greenhouse gases Emissions Verification OHSAS 18001:OccupManagement alth ystemdSafety LINEAR PERFORMANCE WARRANTY Management System 10 Year Product Warranty•25 Year Linear Power Warranty pi al-_ . �L .g (( LISTED 100%- o o �u ...r;ry.®�.0 97% Additi /ra \7 ��a � PVL! 0 90% °nal value from TrinaSolar'slinearWarranty BO% Trinasolar Years 5 ro 15 z5 i♦ Trina Linear Warranty Standard Step Warranty A MAX' pLUs FRAMED 60-CELL MODULE PRODUCTS POWER RANGE ELECTRICAL DATA(STC) TSM-DD05A.08(II) 280-315W TSM-DD05A.05(II) 275-310W Peak Power Watts-PnAx(Wp)* 275 280 285 290 295 300 305 310 315 Power Output Tolerance-PMAx(W) 0-+5 Maximum Power Voltage-VMPp(V) 31.4 31.7 31.8 32.2 32.5 32.6 32.9 33.1 33.3 DIMENSIONS OF PV MODULE(mm/inches) Maximum Power Current-Imp,(A) 8.76 8,84 8,97 9.01 9.08 9.19 9.28 9.37 9.46 947/37.3 Open Circuit Voltage-Voc(V) 38.4 38.4 38.5 38.9 39.6 39.8 40.0 1 40.2 40.5 2 Short Circuit Current-Inc(A) 9.24 9.42 9.51 9.66 9.68 9.77 9.85 9.94 10.0 JunRi°n Box f n �, Module Efficiency nn(%) 16.8 17.1 17.4 17.7 18.0 18.3 18.6 18.9 19.2 L IBJ STC:Irradiance 1000W/m,Cell Temperature 25°C,Air Mass AM15. Namepl Me _ *Measuring tolerance:±30/A ELECTRICAL DATA(NOCT) e g. S Maximum Power-Nor(Wp) 205 209 212 216 220 223 227 231 235 % AL JA Maximum Power Voltage-Vnpp(V) 29.1 29.4 29.5 29.9 30.1 30.2 30.5 30.7 30.9 Maximum Power Current-IMPp(A) 7.04 7.10 7.21 7.24 7.30 7.38 7.46 7.53 7.60 4-09x14 Installing Hole Open Circuit Voltage-Voc(V) 35.7 35.7 35.8 36.2 36.8 37.0 37,2 37,4 37.6 / 604.3 Grounding Hole Short Circuit Current-15c(A) 7.46 7.61 7.68 7.80 7.82 7.89 7.95 8.03 8.10 1Z-Drain Hole NOCT:Irradiance at 800W/m0,Ambient Temperature 20°C Wind speed lm/s. - -e o MECHANICAL DATA 35/1.38 992/39.1 Solar Cells Monocrystalline 156.75•156.75 mm(6 inches) Back View Cell Orientation 60 cells(6 0 10) 11/0.43 Silicon Sealant Module Dimensions 1650•992•35mm(65.0*39.1•1.38 inches) Laminate ®�®,,,,,IN Weight 18.6 kg(41.0 Ib) Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass .-,,L; I Backsheet White[DDO5A.08(II)]; Frame ®�����i ®®® Black[DDO5A.05(II)] 35/1.38 Frame Black Anodized Aluminium Alloy[DD05A.08(II),DD05A.05(II)] (A-A) J-Box IP 67 or IP 68 rated Cables Photovoltaic Technology Cable 4.Omm2(0.006 inchesz), 1000 mm(39.4 inches) I-V CURVES OF PV M0DULE(305W) ,ao Connector Trina T54(MC4 upon request) 9.0 ,000W/m' 00 aoow/m, Fire Type Type 1 or Type 2 7.0 0.0 nuuw,nf v 5.0 5 40 ,00w/.,r TEMPERATURE RATINGS MAXIMUM RATINGS 3.0 2.0 ' NOCT(NominalOperating Cell Temperature) 44°C(±2°C) Operational Temperature -40"+85°C o J) o 10 70 Vol taye(an 40 50 Temperature Coefficient of PMAx -039%/°C Maximum System Voltage 1000V DC(IEC) Temperature Coefficient of Voc -0.29%/°C 1000V DC(UL) P-V CURVES OF PV MODULE(305W) Temperature Coefficient of Inc 0.05%/°C Max Series Fuse Rating 15A(Power<_285W) 350 300 1000W/m 20A(Power 2290W) 350 NOW/m' (DO NOT connect Fuse in Combiner Box with two or more strings in o 2.00 o _� parallel connection) WARRANTY PACKAGING CONFIGURATION oo I_ 0 '� `= 10 year Product Workmanship Warranty Modules per box:30 pieces 0 0 0001nage(v) 40 0 25 year Linear Power Warranty I Modules per 40'container:840 pieces (Please refer to product warranty for details) CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Ti na so I a r ©2017 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to change without notice. Version number:TSM_EN_2018_B www.trinasolar.com 4 .._._ TR SNOW & SUN Engineered Snow Retention Q ROOF ACCESSORY SYSTEMS and Solar Mounting Solutions Z O Q J J H co z 1 . u/, os_ 111111 moll 1 1 1 + 1111♦11 � a 1111OW! M , 1111111 1��► mill •1• hIllj�j �Ij11•11111 I�i�i�i�1i*4-. .I����i1• •i111111i !*I1i 1 -- fr ♦1�11.1 • 1�1--�11 . - *�1�1:1 I T AWNING SYSTEM INSTALLATION INSTRUCTIONS ALL VERTICAL WALLS ©TRA Snow and Sun, Inc.• 1657 South 580 East • American F ork,UT 84003 • Tel:800-606-8980• www.trasnowandsun.com•info@trasnowandsun.com TRA SNOWS1&SUN © TRA Snow and Sun,Inc.• 1657 South 580 East • American F ork,UT 84003 • Tel:800-606-8980• www.trasnowandsun.com•info@trasnowandsun.com TABLE OF CONTENTS Table of Contents 3 I- z Components 4 System Components 6 Attachment Components 7 0 Module Compatibility 8 p System Layout 9 SYSTEM LAYOUT-PORTRAIT CO SYSTEM LAYOUT-LANDSCAPE Pre-Job Layout Preparations 10 Wall Mounts 11 Horizontal Leg 12 Angle Adapter 13 Angled Frame To L-Foot 14 Angled Frame ToAdapter 15 Cross Connectors 16 Bracing 17 Cross Rails 18 Fixed Rail Connector 19 Flexible Rail Connector 20 Microinverter 21 End Clamp & First Module 22 Mid Clamp & Module 23 Cutting Access Rail 24 End Cap 25 Grounding Lug 26 Jumper Wire at Flexible Rail Connector Locations 27 Wire Management Clip 28 Appendix 29 Th414 TRASNOW& SUN Table of Contents 13 /35 ROOF R161SSORI SISTERS © TRA Snow and Sun,Inc.• 1657 South 580 East • American F ork,UT 84003 • Tel:800-606-8980• www.trasnowandsun.com•info@trasnowandsun.com COMPLETE A SITE SURVEY Typicallythe rail span between supporting roof anchors m is the most important design consideration. 1. Obtain a set of roof plans or draw your own. O 2. Verifythat all dimensions are correct. A solar checklist form and web resources are available W at http://trasnowandsun.com/solar-mounting/solar p://trasnowandsun.com/solar mounting/solar 3. Note locations of roof penetrations (chimneys, mounting checklist/. Solar checklist information must O vents, etc.) be provided along with jobsite information (preferably a roof plan) in order to provide the free solar array 4. Note the roof construction materials and locate layout. For more details contact TRASnow and Sun. framing member locations, paying attention to the spacing of the framing members. 5. Assess objects creating shading concerns 0 z DETERMINE THE SOLAR LAYOUT 1. It is recommended that your design be approved by a local building authority before beginning installation. 2. The solar layout should be designed with the following factors in mind that affect the structural design of the solar array: • Windspeed • Building height • Snow load • Exposure category • Importance factor • Roofslope/pitch 3. Other factors to be considered: • Sun exposure • Objects causing shading • Proximity to inverters/electrical panels • String capacities, etc. 4. Some local jurisdictions'fire codes require walkways or edge clearances. Th)11411 .- TRASNOW& SUN Pre-Job Layout Preparations 14 /35 ROOF RSt1SSRRl 3111[X3 ©TRASnow and Sun,Inc.• 1657 South 580 East • American F ork,UT 84003 • Tel:800-606-8980• www.trasnowandsun.com•info@trasnowandsun.com H Z W Z 0 0 2 O U TRASNOT' SUN Components 15 /35 © TRA Snow and Sun,Inc.• 1657 South 580 East • American F ork,UT 84003 • Tel:800-606-8980• www.trasnowandsun.com•info@trasnowandsun.com ROOF ATTACHMENTS 0 0 K il0 z m z 10 •" L-FOOT 0 :: .l‘ EXTENDED L-FOOT 77000502 77000512 II � :-Foo,T 77000502A MODULE CLAMPS RAIL CONNECTORS Plt:.0 N -NN, ‘iiicl) 4 I. rilkill ,„ 4 0 --,, --- Q 0 MID CLAMP ASSEMBLY END CLAMPASSEMBL 15101XXX 15102XXX CROSS CONNECTOR FIXED FLEX CONNECTOR 74011001 740XXXXX -44t, ;4.1 THIN FILM THIN FILM MID CLAMPASSEMBLY END CLAMPASSEMBL p�,I 11' p �+ 72203XXX 72203XXX TRASNOW„a`SUN Components 16 /35 �j YtSc ©TRA Snow and Sun,Inc.• 1657 South 580 East • American F ork,UT 84003 • Tel:800-606-8980• www.trasnowandsun.com•info@trasnowandsun.com ACCESSORIES 4 et 04\ . \ 11\14\. ... w 1 ,4 Z o WIRE MANAGEMENT CLIP U RAIL END CAP SOLAR RAIL PLUS 18000335 72215XXX 7403XXXX At _ '----, e. '0 .40 WEEB LUG 8.0 WEEB-SMC 2 WEEB-LUG WEEB-SMC FASTENERS +', ), �\4,4 ..,, M8 FLANGELOCK NUT SLIDING BLOCK 15100041 151100025 ,r, 55mm Omm �� 45mm 40mm . . -, --- •,.' : g:— 35mm ______ '30mm = — 25mm ,, 7:-- i-- 20mm 16mm � 10mm SDS SCREW 15100023 15100038 15100151 15100019 15100015 SD S S 101 151000 58 15100022 15100021 15100020 15100018 p�,I 11' p �+ SOCKET HEAD CAP SCREW *Actual Size TRASNOW„a`SUN Components 17 /35 �j YtSc ©TRA Snow and Sun,Inc.• 1657 South 580 East • American F ork,UT 84003 • Tel:800-606-8980• www.trasnowandsun.com•info@trasnowandsun.com SYSTEM COMPONENTS cn e 0 cnQ 0 n � O 0 O f' 0 • 0 z cn \a 0 Q SOLAR RAIL PLUS: Supports PV modules 0 ROLL IN BLOCK:Easily clips into place in the top and accessories.Availablein lengths up to 20'6". channel of the Solar Rail Plus!for easy Mid/End Clamp Extruded aluminum. Available in mill finish or black placement.Provides electrical bond between Mid Clamp anodized. or End Clamp to the rail. Mill finish aluminum. Q CROSS CONNECTOR:Supports cross braced 0' L-FOOT: Secures rails to wall. Mill finish aluminum. mounting systems.Aluminum mill finish or black 0 M8 SOCKET HEAD CAP SCREW:Use when anodized. securing components to the Solar Rail Plus in O FLEXIBLE RAIL CONNECTOR:Joins and aligns conjunction with the Sliding Block or Solar Grounding rail sections allowingforexpansion due to natural Clip.Stainless Steel. temperature variation. Instal ledevery 50'of Solar Rail ® END CAPS: Provide a clean, finished appearance Plus. Mill finish aluminum. (Non-bonded) on ends of Solar Rail Plus concealing any rough edges. O FIXED RAIL CONNECTOR:Joins, aligns,and Polypropylene End Cap available in grey or black. electricallybonds rail sections into single length of 0 GROUNDING LUG (WEEB LUG 8.0): Used to ground rail.Available in mill finish or black anodiz ed. the Solar Rail PI us to a copper ground wire. Includes a O END CLAMP ASSEMBLY: Includes End Clamp, stainless steel washer and a tin-plated copper I ug. Solar Grounding Clip, and M8 Socket Head Cap 0 SLIDING BLOCK:Provides threaded connection point Screw to Solar Rail Plus.Rollsand slides into place in channels O MID CLAMP ASSEMBLY: Includes Mid Clamp, of Solar Rail Plus. Mill finish aluminum. Solar Grounding Clip, M8 Socket Head Cap Screw 0 ANGLE ADAPTER: Used to connect two pieces of rail O END CLAMP: Pre-assembled End Clamp with at an angle to join the tilted portion of the structure. Solar Grounding Clip (SGC) provides module to rail bond. End Clamp available in mill finish and black anodized. O MID CLAMP: Pre-assembled Mid Clamp with Solar Grounding Clip (SGC) provides module to module and module to rail bond. Mid Cl amp avail abl e in mill finish and black anodiz ed. Th)111411 .- TRASNOW& SUN System Components 18 /35 ROOF AECESSRRI SISTERS ai ©TRA Snow and Sun,Inc.• 1657 South 580 East • American F ork,UT 84003 • Tel:800-606-8980• www.trasnowandsun.com•info@trasnowandsun.com AWNING LANDSCAPE(OPTION A) AWNING PORTRAIT (OPTION B) w I— Z ��� UJZ ♦ 1�♦ j�j1�•� �. ••11�1� I��j11♦•1 - z 1♦ ♦ ♦�1 1♦1�♦11♦1♦•1• ��11 ��j���1.'- / w ,����1♦��1 j•1: ��1♦�•. ♦11111Air ♦�j1 Air .♦* _ ♦ 1� �� 1 ♦ 1 Q ♦ 1 1•/ ♦1♦• . Q ,11*1 TRASNOW&SUN Attachment Components 19 /35 ROOF ASCRSSRRY SISfEYS �j YtSc ©TRA Snow and Sun,Inc.• 1657 South 580 East • American Fork,UT 84003 • Tel:800-606-8980• www.trasnowandsun.com•info@trasnowandsun.com