F17-0021_Hydraulic Report1_1498145640.pdf
Hydraulic Summary Report Description: Residential Job Number: 1 Node Flow(gpm) Total Hose Streams 0.0 Safety Margin Required Available Node Hose Flow Static Residual Flow Total Demand (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) @ @ Name 9 146.6 126.8 19.8 724.0 77.3 150.0 137.7 Water Supply Design Engineer Job Number Total Water Required (Including Hose Allowance) 137.7 Maximum Pressure Unbalance In Loops 0.0 Additional Hose Supplies 0.0 Hose Allowance At Source Supplies 136.4gal Residential 0.10gpm/ft² 256.00ft² 900.00ft² (Actual 942.91ft²) 4 Occupancy Area of Application Coverage Per Sprinkler Number Of Sprinklers Calculated Density Job Suffix AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Volume capacity of Dry Pipes Volume capacity of Wet Pipes 3.16 between nodes 8 and 7 Maximum Velocity Under Ground 25.82 between nodes 2 and 104 Maximum Velocity Above Ground 5.8 K-Factor 38.0 at 42.9 Most Demanding Sprinkler Data System Vail, CO Job Site/Building Villa Cortina #350 AHJ Villa Cortina Job State Certification/License Number Job Name: Josh Adam 1 Contractor Contractor Number Name of Contractor: Address 1 Address 2 Contact Name Contact Title Extension Phone FAX E-mail Web-Site Address 3 Address 1 Address 2 Drawing Name Villa Cortina #350 System Flow Demand 137.7 Remote Area(s) Address 3 6/13/2017 © M.E.P.CAD, Inc. Page 1 AutoSPRINK® 12 v12.0.59.0 8:14:56AM Vail Fire & Emergency Services 06/22/17 Hydraulic Graph Report Description: Residential Job Number: 1 77.3 @ 724.0 Residual: Pressure 150.0 Static: Pressure Water Supply at Node 9 Hydraulic Graph Water Supply at Node 9 126.8 @ 137.7 126.8 @ 137.7 Available Pressure at Time of Test 146.6 @ 137.7 System Demand System Demand (Including Hose Allowance at Source) © M.E.P.CAD, Inc. 6/13/2017 Page 2 AutoSPRINK® 12 v12.0.59.0 8:14:58AM Vail Fire & Emergency Services 06/22/17 Device (gpm) Actual Flow Minimum Flow (gpm) (K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Residential Job Number: 1 Sprinkler 101 38.0 38.0 5.8 42.9 Sprinkler 102 29.3 13.0 4.3 46.4 Sprinkler 103 40.1 38.0 5.8 47.8 Sprinkler 104 30.3 13.0 4.3 49.5 Most Demanding Sprinkler Data © M.E.P.CAD, Inc. 6/13/2017 Page 3 AutoSPRINK® 12 v12.0.59.0 8:14:59AM Vail Fire & Emergency Services 06/22/17 Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 1 Report Description: Residential • • • • • Route 1 • • • • • Pf Pe Pv BL 1.055 38.0 13.95 0.274618 8'-3¾ 3.5 101 0'-0 38.0 5.8 42.9 4'-6 102 0'-0 46.4 12'-9¾ 150 Sprinkler, 2E(2'-0), Tr(0'-6) Pf Pe Pv BL 1.055 67.3 24.70 0.790692 3'-6¼ 4.4 102 0'-0 29.3 4.3 46.4 2'-0 1 0'-0 50.8 5'-6¼ 150 Sprinkler, T(2'-0) Pf Pe Pv CM 1.291 67.3 16.50 0.295826 11'-7-5/8 3.4 1 0'-0 50.8 2 0'-0 54.3 11'-7-5/8 150 Pf Pe Pv CM 1.527 137.7 24.12 0.490783 54'-7-1/8 34.4 2 0'-0 70.4 54.3 15'-6 4.3 3 -10'-0 93.0 70'-1-1/8 150 Flow (q) from Route 2 3T(3'-6), 2E(2'-6) Pf Pe Pv CM 2.009 137.7 13.93 0.129025 10'-0 1.7 3 -10'-0 93.0 3'-6 4 -10'-0 94.7 13'-6 150 E(3'-6) Pf Pe Pv FM 2.157 137.7 12.09 0.137917 59'-6-5/8 8.8 4 -10'-0 94.7 4'-3¾ 4.1 5 -19'-6-5/8 107.7 63'-10-3/8 120 fE(4'-3¾) Pf Pe Pv FM 2.635 137.7 8.10 0.052032 3'-9 0.2 5 -19'-6-5/8 107.7 1.6 6 -23'-3¾ 109.5 3'-9 120 Pf Pe Pv FM 4.260 137.7 3.10 0.005015 14'-11-7/8 12.7 6 -23'-3¾ 109.5 31'-7¼ 2.5 7 -29'-0¾ 124.7 46'-7-1/8 120 2LtE(7'-10¾), BFP(-8.5), PRV(-4.0), BV(15'-9-5/8) Pf Pe Pv UG 4.220 137.7 3.16 0.003948 3'-7-1/8 0.1 7 -29'-0¾ 124.7 16'-8¾ 1.6 8 -32'-7¾ 126.4 20'-3¾ 140 E(16'-8¾) Pf Pe Pv UG 4.260 137.7 3.10 0.003770 120'-0 0.5 8 -32'-7¾ 126.4 9 -32'-7¾ 126.8 120'-0 140 Water Supply 137.7 0.0 Hose Allowance At Source 9 • • • • • Route 2 • • • • • Pf Pe Pv BL 1.055 40.1 14.72 0.303392 5'-1-3/8 1.7 103 0'-0 40.1 5.8 47.8 0'-6 104 0'-0 49.5 5'-7-3/8 150 Sprinkler, Tr(0'-6) Pf Pe Pv BL 1.055 70.4 25.82 0.858378 3'-6¼ 4.7 104 0'-0 30.3 4.3 49.5 2'-0 2 0'-0 54.3 5'-6¼ 150 Sprinkler, T(2'-0) 1.51 4.87)( 150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc. 6/13/2017 Page 4 AutoSPRINK® 12 v12.0.59.0 8:15:01AM Vail Fire & Emergency Services 06/22/17 Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: 1 Report Description: Residential Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc. 6/13/2017 Page 5 AutoSPRINK® 12 v12.0.59.0 8:15:01AM Vail Fire & Emergency Services 06/22/17