HomeMy WebLinkAboutDRB18-0551_Approved Documents_1541008189.pdfACTION FORM
Design Review Board (DRB)
Department of Community Development
75 South Frontage Road West
Vail, CO 81657
Tel: 970-479-2139
www.vailgov.com
Project Name: Hill Run Limited 2018 Application Number: DRB18-0551
Application Type: Exterior Alteration Date Applied: 10/29/2018
Project Description: Addition of exhaust vent for new gas fireplace
CONTACTS
Contact Type: Applicant
Full Name: Dennis Kuznetsov (Dennis Kuznetsov)
Address: PO Box 83 . Vail, CO 81658 Phone: 5105665531
Contact Type: Property Owner
Full Name: HILL RUN LIMITED VAIL SMITH PROPERTIES ATTN: PAUL SMITH
Address: Phone: None
Project Address: 1755 W GORE CREEK DR (210312306004) (210312306004)
Job Site Location:
Legal Description: Subdivision: VAIL VILLAGE WEST FILING 2 Lot: 6 Block:No
Data
Parcel Number: 210312306004
BOARDS/STAFF ACTION
Motion By: Action: Staff Approved
Second By:
Vote: Date: 10/31/2018
Conditions:
- Planning and Environmental Commission approval shall not become valid for 20 days following the date of
approval pursuant to Section 12-3-3, Appeals, Vail Town Code.
- No changes to these plans maybe made without the written consent of Town of Vail staff and/or the
appropriate review committee(s).
- The applicant shall paint the vent to match exterior of the home.
Planner: Ashley Clark
Fireplace
Vertical Termination
Cathedral Ceiling
Stove Installation
Co-Linear Insert
Installation
Masonry Chimney
Conversion
Stove with Snorkel
Horizontal Termination
Stove
Horizontal Termination
Metal Chimney
Conversion DirectVent® ProDirectVent® Pro
Unitized, co-axial venting
system for direct vent
gas or propane stoves
and fireplaces.
Step 1. Choose appropriate size venting for the appliance and installation.
Step 2.Refer to the Typical Installations for the type of installation similar to
your situation. Identify the needed parts for installation.
Step 3.
The size of your VENTING should match the outlet size on your
appliance. An Appliance Adapter may be required and supplied by your
appliance manufacturer.
Step 4. Determine the overall length of venting pipe needed.
Step 5.Be sure to follow appliance instructions, concerning clearances and
requirements for maximum horizontal or minimum vertical venting runs.
Step 6.
If a free-standing appliance is used, select the vent or stovepipe pieces
to connect from the appliance to the liner (refer to the appropriate
DuraVent catalog section). Consult appliance instructions for required
distances from any Termination Caps.
Step 7.
Important! Check to be sure the installation complies with all local
and national code requirements, including clearance to combustibles.
Contact the local building inspector for permit requirements.
How To Plan Your Installation
• Refer to our Typical Venting Installation to
select the appropriate component parts for
your installation.
• The inner and outer pipe diameters should
match the outlet size of the appliance.
• Check the appliance manufacturer's
installation instructions to confirm
which types of vent configurations are
permitted (i.e. horizontal, vertical, chimney
reline, etc.). Also, check for any venting
restrictions such as maximum horizontal
run, minimum and maximum vertical rise,
maximum offset, etc.
Typical Installations Installation
How It Works
Direct vent appliances are 'sealed combustion systems'.
That means the air for combustion is delivered to the
appliance through the venting system from outside. As
a result, direct vent appliances do not consume warm
indoor air for combustion and are not subject to oxygen
starvation, poor draft and other problems associated with
'tight' energy efficient homes. With sealed direct vent
systems, all combustion byproducts are safely vented out
through the venting system, eliminating fumes, water
moisture, and indoor air contamination.
DirectVent Pro
1 Vertical Termination Cap
2 Storm Collar
3 Flashing
4 Cathedral Ceiling Support Box
5 Pipe
6 45° Elbow
7 Class A Chimney Conversion Kit
8 4" Flex
9 90° Elbow
10 Horizontal Termination Cap
11 Snorkel Termination Cap
12 Colinear Kit
13 3" or 4” Flex
14 Co-Axial to Co-Linear Connector
15 Masonry Chimney Conversion Kit
16 Elbow Strap
Sconce Termination Cap
90° Elbow
Straight Pipe Length
Wall Thimble Cover or
Wall Thimble
1
2
3
4
5
5
5
1
3
2
5
6
16
6
5
6
1
7
8
7
5
15
15
15
8
5
5
9
1
15
13
12
13
12
5
10
5
9
5
5
11
H O T
800.835.4429 | 707.446.4740 Fax | www.duravent.com
L910_810007457_Brochure_DirectVent Pro_05-28-17_V2
Professional Technical Help
DuraVent prides itself on providing the best customer
service and technical support in the industry.
Our Customer Support Team is available to answer
technical questions.
Monday – Friday
5:30am – 4pm PST | 8:30am – 7pm EST
Tel: 800-835-4429
Fax: 707-446-4740
customerservice@duravent.com
Contact
Applications
DirectVent Pro is a unitized, coaxial venting system
designed for use with direct vent gas or propane
stoves, heaters, and fireplaces.
Materials and Construction
.020” aluminum inner wall.
.018” galvanized steel outer wall.
Painted outer walls made of laser-welded .018”
galvalume steel. Caps also available in stainless
steel and copper. Outer pipe brings combustion air
to the appliance. Inner pipe exhausts flue gases to
the outside. Gaskets or sealants not required (unless
specified by the appliance manufacturer).
Clearances
Specified by the appliance manufacturer.
Diameters
4” x 6 5⁄8” and 5” x 8”.
Listings
DirectVent Pro, in combination with the
gas appliance, has been tested and listed
as a decorative gas appliance system
or as a direct vent heater system by a
major testing agency, such as UL, CSA, or
Warnock Hersey.
DirectVent Pro
Utilizing state-of-the art manufacturing, DirectVent Pro
features tight inner connections for superb performance,
with no gaskets or sealants required (unless specified by
the appliance manufacturer). All black pipe lengths, pipe
extensions, and elbows feature laser-welded outer wall
seams for a sleek finish. Low-profile locks and no hems or
beads allow for a beautiful product that looks elegant in
any interior.
DuraVent's direct vent is specified exclusively by nearly
every major stove and fireplace manufacturer in the U.S.
and Canada, with the largest choice of termination caps for
direct vent available.
Product List
Horizontal Termination Kit A
Kit includes: 90° black elbow, ceiling support/wall
thimble cover, 24” black pipe, 8 1⁄2” black pipe extension.
Termination cap not included. 4” x 6 5⁄8” Direct Vent.
Horizontal Termination Kit C
Kit includes: 90° black elbow, wall thimble, wall thimble
cover, 24” black pipe, 8 1⁄2” black pipe extension.
Termination cap not included. 4” x 6 5⁄8” Direct Vent.
Masonry Chimney Conversion Kit
Kit 46DVA-KMC includes: Cap Adapter, 18” x 18” Flashing,
Round Ceiling Support/Wall Thimble Cover, Retro
Connector. For 4” x 6 5⁄8” direct vent. Termination Cap
and 4” flex are sold separately. Kit 46DVA-KCT includes:
Cap Adapter and an 18” x 18” Flashing. Use with 4” x 6 5⁄8”
direct vent gas stoves.
Chimney Conversion Kit
Kit includes: Cap Adapter & Retro Connector. For 4” x 6 5⁄8”
direct vent. Use with metal chimneys. 4 inch flex
sold seperately.
Pipe
Painted black or galvanized. 4” x 6 5⁄8” & 5” x 8” sizes. 6”,
9”, 12”, 18", 24”, 36” , 48” & 60" lengths.
Pipe Extension
One-piece Pipe Extension, in 8 1⁄2” and 16” lengths, slides
over pipe for precise length needed. Painted black or
galvanized. 4” x 6 5⁄8” & 5” x 8” sizes.
Adjustable Pipe
Use to add length to a straight length of DirectVent Pro. 2
piece telescopic.
30°/ 45°/ 60°/ 90° Elbows
Painted black or galvanized. All elbows swivel. Fixed
angle. 4” x 6 5⁄8” and 5” x 8”.
Elbow Strap
Use for supporting vent pipe between offsets.
Ceiling Support/ Wall Thimble Cover
Decorative cover painted black. Also used as a flat ceiling
support cover.
Cathedral Ceiling Support Box
Use to pass through ceiling and support pipe. Painted
black, 14” tall. Trim included.
Flat Roof Flashing
Use to weather proof the penetration of vent pipe
through a flat roof.
DSA Flashings
Forms to fit on metal or tile roofs. Available in adjustable and
steep roof styles. Made of malleable dead soft aluminum.
Storm Collar
Use to maintain a weather tight seal between pipe
and flashing.
Round Horizontal Termination Cap
Use for through-the-wall terminations. Available in
aluminum only.
Sconce Termination Cap
Use for horizontal through-the-wall terminations.
Aluminum, stainless steel, or copper.
High-Wind Sconce Termination Cap
Use for horizontal through-the-wall terminations.
Provides improved performance in high wind conditions.
Aluminum, stainless steel, or copper.
Square Horizontal Termination Cap
Use for through-the-wall terminations. Aluminum,
stainless steel, or copper.
Snorkel Termination Cap
Use when a vertical rise is needed to meet minimum
heights. For horizontal through the wall applications.
Available in 14" and 36" heights.
Horizontal Windguard
Use with terminations in high wind conditions. For
through-the-wall applications. Fits all caps and snorkels.
High Wind Termination Cap
Use in high wind conditions. For vertical applications.
Vertical Wind Guard
Use for horizontal through-the-wall terminations when
a vertical rise is desired in the system to meet appliance
manufacturer recommended minimum heights. Do not
enclose in the wall or install below grade.
Wall Thimble and Wall Thimble Reduced
Provides a complete wall-pass-through and firestop.
Universal Wall Thimble
Provides a complete wall-pass-through and interior
firestop. Features an adjustable sleeve for an exact fit.
Eliminates visible trim on exterior or wall near cap. Works
well for smaller square and sconce termination caps.
Wall Firestop
For horizontal through-the-wall installations.
Vinyl Siding Standoff
Use as a heat shield on structures with temperature
sensitive siding.
Vinyl Siding Standoff Kit and
Vinyl Siding Standoff Kit - Reduced
Use as a heat shield on structures with temperature
sensitive siding. 4-piece design. For Sq. Horizontal Cap.
Reduced version for Sconce & Round Horizontal Cap.
Counter Flashing Kit and
Counter Flashing Kit - Reduced
Prevents water intrusion into stucco-sided homes.
Reduced version for Sconce & Round Horizontal Cap.
Ceiling Firestop
Use for multi-story vertical installations at second floor
and subsequent floors.
Attic Insulation Shield
Use for installations that pass through an attic to prevent
insulation and debris from accumulating near the vent.
Wall Strap
Use to support pipe. Provides 1” clearance. Install at 4'
intervals on vertical runs.
Restrictor Disk
Use when required by appliance manufacturer to restrict
incoming combustion air.
Adjustable Roof Flashing
Use to weather proof the penetration of vent pipe
through the roof. 0/12”-6/12”
Steep Roof Flashing
Use to weather proof the penetration of vent pipe
through a steep roof. 7/12”- 12/12”.
Low Profile Termination Cap
Use for vertical terminations only. Aluminum and
stainless steel.
Extended Vertical Termination Cap
Use in extremely cold climates. Separates air intake vents
from exhaust area.
Chimney Liner Flex Extension
Use with co-linear and flex system. 3” x 35’ and
4” x 35’.
Flex Coupling
Use to join flex liner sections together. 3” and 4” flex.
Co-Axial to Co-Linear Connector
Use Co-Linear Adapter for stoves with co-axial outlets.
Refer to stove mfg installation instructions for approval.
Chimney Liner Termination Kit
Kit includes: Termination Connector and Flashing. Caps &
flex sold separately.
Appliance Adapter
Attaches to appliance outlet allowing pipe to easily
connect or disconnect. Vermont Castings Adapter #2768.
Monessen Adapter
Allows the installer to attach DuraVent’s DirectVent Pro 4 x
6 5⁄8” pipe to a Monessen 4 x 7 direct vent exhaust outlet.
Reducer
Use to reduce vent diameter from 5”x 8” to 4” x 6 5⁄8”.
Check with appliance manufacturer for approval.
Co-Linear Flex Connector
Use as a flex connector with inserts with 3” co-linear
intake and exhaust ports.
Co-Linear Kit w/ Flex
Use when installing a direct vent co-linear insert into a
masonry chimney.
Kit includes: Choice of High-Wind Termination Cap or
Prairie Termination Cap; and two pieces of Aluminum Flex
lengths, the exhaust marked with red colored tape.
DirectVent® Pro