HomeMy WebLinkAboutB18-0472_10-9-18 - SSCV Clubhouse - Solar Calculations_1540920193 (2).pdfPage 1 of 4 10/16/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233/info@activeenergies.com) Site: SSCV Clubhouse 598 Vail Valley Drive Vail, CO 81657 System Layout: Single Panel = 5.32ft tall X 3.67ft wide Panel Arrangement: see layout below; panels oriented in the landscape position, mounted flush on the roof. The Holy Cross electric meter, PV Production meter, disconnect, and inverter to be located inside of the building, in the electrical room. Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F All AC wiring to be completed by a Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer HCE, PV meter, disconnect, and inverter (inside building, electrical room) Panel arangement and wiring not reviewed or approved ROUGH ONLY 10/30/18 Page 2 of 4 10/16/2018 Calculations 39.6kW System Size (STC) 110 Solaria PowerXT solar panels @ 360 watts 110 SolarEdge P370 optimizers 1 SolarEdge SE43.2kUS inverter (comprised of 3 x 14.4kW inverters) (9-17 min- max optimizer/string length) Inverter “1” – 3 strings of 12/12/13 modules/optimizers; Inverter “2” – 3 strings of 12/12/13 modules/optimizers; Inverter “3” – 3 strings of 12/12/12 modules/optimizers Fixed array tilt angle: 14.04º/18.43º Array azimuth: 180º/90º/270º (where 180º is magnetic south) Estimated Production: 55,405kWh/year (not including shading) Maximum PV System Voltage: 690.7 Voc = 47.7V/module 47.7V x 1 module = 47.7V Temperature correction factor 690.7(A) STC = 25°C, Temperature Coefficient (Voc) = -0.29 %/°C (-40°C - 25°C) = 65°C 47.7V + (-65°C x (-0.29%/°C x 47.7V) x 1 module) = 47.84V Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Isc = 9.56A 9.56A x 1.25 = 11.95A Maximum PV Output Circuit (Array) Current (per inverter): 690.8 (A)(2) Max Input for SE43.2kUS inverter = 114A (38A/individual inverter) Inverter Output Circuit Current: 690.8 (A)(3) SE43.2kUS 120A @ 208V per phase 10/30/18 Page 3 of 4 10/16/2018 Conductor Sizing SE14.4KUS Panel/Optimizers to Inverter (combined string): Inverter limit 38A combined string 690.8 (B)(1) 38A x 1.25 = 47.5A #8THHN Table 310.16 55A (90ºC column, see note 240.4(D)) No Conduit fill adjustment Table 310.15 (B)(2)(a) SE14.4KUS Panel/Optimizers to Inverter (separate strings): 13 panels x 360w = 4,680w ÷ 400v = 11.7A 11.7A x 1.25 = 14.625A #10 THWN-2 Table 310.16 40A (90ºC column, see note 240.4(D)) Temperature correction factor Table 310.16 40A x .77 = 30.8A Conduit fill adjustment Table 310.15 (B)(3)(a) Use .8 for 4-6 current carrying conductors 30.8A x .8 = 24.6A SE43.2kUS Inverter to Disconnect, Production Meter and Backfeed Point: 120A @ 208V 120A x 1.25 = 150A 690.8 (B)(1) 1/0 THHN Table 310.16 150A (75ºC column) No Conduit fill adjustment Table 310.15 (B)(2)(a) No Temperature correction factor Table 310.16 150A 3p Overcurrent Protection Device Conductors may be oversized for voltage drop 10/30/18 Page 4 of 4 10/16/2018 6 #10 PV Wire 1# 6G Bare Cu Conductors in Free Air Inverter w/ Integrated DC Disconnect SolarEdge SE43.2kUS, NEMA 3R Max AC Output: 120A @ 208V DC Grounding Electrode Conductor solid bare #6 Cu per NEC 250.66(C)Service Panel Line Diagram SSCV Clubhouse 598 Vail Valley Drive Vail, CO 81657 39.6kW Utility Interactive Photovoltaic System Modules: 110 Solaria PowerXT 360 Voc = 47.7V Isc = 9.56A Optimizers: 110 SolarEdge P370 Inverter: SolarEdge SE43.2kUS (= 3 x 14.4kUS) 3 Strings X 12/12/13 Modules/Inverter 3 Strings X 12/12/13 Modules/Inverter 3 Strings X 12/12/12 Modules/Inverter Operating Voltage: 400V Operating Current: 27.1A Max System Voltage: 600V Max Output Current: 45A Tilt Angle: 14.04º/18.43º Array Azimuth: 180°/90º/270º Production: 55,405kWh/yr Notes: - See Calculation Sheet for conductor sizing. - All conductors are copper unless otherwise noted. - Inverter listed (UL-1741) to de- energize upon loss of utility voltage per NEC 690.61. - Inverter has integral ground-fault protection per NEC 690.5 - 208V 3 Phase Service Panel rating of 800A (bus rating 800 amp and 800 Main disconnect) to accommodate 800A + 150A = 950A supply (up to 120% of connected power sources from residential installations per NEC 690.64(B)(2)) Array mounted on roof 110 Solaria PowerXT 360w Solar Panels 110 SolarEdge P370 DC Optimizers In Electrical Room Pass-Thru Box Located on roof Placard on meter and main panel stating ”Photovoltaic System Connected” per Holy Cross specifications ~+/-200' MC Cable 2 # 8 THWN-2 1 #10 THWN-2 G OR ¾" C EMT 6 #10 THWN-2 1 #10 THWN-2 G 14 15 16 25... 26 27 28 37... Backfeed Breaker: 150A 3p 208v +/-5' ¾" C EMT/PVC/FNMC/other 4 1/0 THHN 1 #6 Ground 150A 1 2 3 13... PV Disconnect >=150A Adjacent to meter Net Meter Production Meter w/ lever bypass adjacent to net meter 37 Panels and Optimizers (same as above) 36 Panels and Optimizers (same as above) 10/30/18