HomeMy WebLinkAboutA17-0048_FA3.01_1506356580.pdf Oj 055 111700 16. Vail Fire&Emergency Services 09/25/17 0 Hi BEDROOM 2 O 0 0 \ TOWN STAMP reviewed/approved . Where are the i, CLOSET WATER ENTRY engineered s drawings ? KITCHEN O4"SQ MECH 3S 9 I ELEC O ITYPICAL O 0 ,_ _ T-Slii--------- ---- 0 0 L I 6 I 1 — Ell ------- _ IMASTER BATH (( I _, 1 1 0 I 0 0 DINING I E 1 CAR GARAGE . — TSB/CO CLOSET 2'8"I 0 \ 3' 2'8'- 2'6° I BATH ,J W in L I J /COI Sla / SBJ I LAUNDRY MIN 3' 2 DISCIPLINE STAMP ri 111 FIRE ALARM LEGEND: o LIVING SYMBOL 1 DEVICE DESCRIPTION ENTRY 0 0 FAC P Fire Alarm Control Panel 'In= KEY Fire Alarm Keypad/Annunciator �� MASTER — OBEDROOM I� jj Z- 11 ' Sprinkler Waterflow Switch . k —1 ICE >IC �(?', Sprinkler Valve Tamper Switch ®SE Smoke Detector w/Sounder Base — — — — Multisensor Device, Smoke & Z OSB/CO Carbon Monoxide Detector w/Sounder Base UNIT 2.1 A - LEVEL 01 - RCP2 - - 0 2 UNIT 2.1 ALEVEL 02RCP 2 1/4" = 1-0" 1/4" = I-0" FIRE ALARM NOTES: Q 1 . FIRE ALARM SYSTEM SHALL BE DESIGNED PER NFPA 72 I AND VAIL FIRE & EMERGENCY SERVICES REQUIREMENTS. 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND I — .- ARE ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE ALARM I CONTRACTOR IS RESPONSIBLE FOR DEVICE LOCATIONS, SYSETM DESIGN AND INSTALLATION. \ I / 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATE ��vI -- — ------ TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. — 1 I\ Il i ° ii _ i I_ ISSUE N Im ilil 4. PROVIDE CARBON MONOXIDE DETECTION PER COLORADO I p — I FIRE ALARM FACTORY STATE LAW, NFPA 720 AND VFES REQUIREMENTS. CLOSET• WATER ENTRY �_ , 1 L I INSTALL DRAWINGS 5. EACH TOWNHOUSE UNIT SHALL HAVE A DEDICATED FIRE • BEDROOM 2 CP ii ALARM CONTROL PANEL TO SUPERVISE SMOKE AND COdi KEY PLAN DETECTORS AS WELL AS THE FIRE SPRINKLER SYSTEM. r H l — 1 BOILER MECH 6. SMOKE DETECTORS MUST BE INSTALLED AT LEAST 3' AWAY i� 1 FROM CEILING FAN BLADES. il _IL 1 KITICHEN LiLu7. FIRE ALARM SYSTEM INSTALLATION WILL OCCUR ON SITE IN ©SB o I k VAIL. MODULAR CONSTRUCTION WILL INCLUDE BOXES AND l #18-6 "' PATHWAYS. iiT WIRE, 1 I JI 1 M (910:A . I o I SHEET TITLE � — DINING UNIT 2.1 A - FIRE ALARM 1 '���. 1 CAR GARAGE u I I BATH 11_,I I (9SB/C0 1 I_ 1 TO ABOVE CLOSET co © SB/C0 J a LIVING REVISION EI LAUNDRY 1 d I: m o� lacY ENTRY I I IL FROM .50 �_ — , BELOW K z 0 E I MASTER I II y�� � BEDROOM iLo ��a II _ J --i- J�I-J 2 I I OVERHANG ABOVE — E N gd N 4 UNIT 2.1 A - LEVEL 01 - FLOOR PLAN 4 UNIT 2.1 A - LEVEL 02 - FLOOR PLAN PROJECT NUMBER PROJECT NUMBER 1/4" = 1-0" I 1/4" = 1-0" ISSUE DATE JULY 13,2017 2 5. r SHEET NO. N5. \ OTE: FLOOPLA\ S 0 \ LOWER POTIO \ OF DAWI \ G ILLUSTRATE DEVICE LOCATIO \ S A\ D WRI \ G . SCP N PLA\ S 0 \ UPPED POTION OF DAWI \ G ILLUSTRATE 30X LOCATIONS DIVE\ SIO \ ED TO THE SCP . FA3.01 N N