HomeMy WebLinkAboutA17-0048_FA3.04_1506356580.pdf 111; iiii ,1111121 stC X 0j, 055 147100 I Vail Fire&Emergency Services • 'i' 09/25/17 —11 113_11 1 I \ - HALLWAY I I - TOWN STAMP �p� _ — I - p il 44 I I I I I I KITCHEN H SB 1_ 359 I \> 0 --min 3' ©� LAUNDRY 3'6" BEDROOM = L ] N J P I I I BATH 2 CAR GARAGE I I DESIGN BATH L._ I (---) WATER ENTRY d r0 — 0 I ® 0 I H- 7 0 0 0 DINING CLOSET I 0 1'6 SB/CO" _g„ — CLOSET J II CLOSET `!SB L-2'6" �� L \ MECH 0 0 mir 3' 1 ENTRY s 4"SQUARE — ELEC BOX, 0 0 TYPICAL OSB/CO BEDROOM . 3'8" LIVING 4O P „ DISCIPLINE STAMP FIRE ALARM LEGEND: — o SYMBOL DEVICE DESCRIPTION O MASTER ilie in 3' BEDROOM FACP *I� MASTER BATH Fire Alarm Control Panel 1 SB trill KEY 2,1" - - i - Fire Alarm Keypad/Annunciator 1'10» _ r ,, 4 ❑ 0 Sprinkler Waterflow Switch ICE F�, Sprinkler Valve Tamper Switch - --. 1 >I - IL. L. OSB Smoke Detector w/Sounder Base Multisensor Device, Smoke & OSB/CO Carbon Monoxide Detector w/Sounder Base z UNIT 3.2A - LEVEL 01 - RCP - - - - 0 2 UNIT 3.2 ALEVEL 02RCP UNIT 3.2 ALEVEL 03RCP FIRE ALARM NOTES: 1/4" = 1'-0" 2 1/4" = 1'-0" 2 1/4" = 1'-0" 1 . FIRE ALARM SYSTEM SHALL BE DESIGNED PER NFPA 72 ICE AND VAIL FIRE & EMERGENCY SERVICES REQUIREMENTS. I 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE LOCATIONS, SYS ETM DESIGN AND INSTALLATION. _ 8 T' Cs ° ❑ 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATE I I I I o I o , HALLWAY TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. I 1 u esB/co DN I I / 4. PROVIDE CARBON MONOXIDE DETECTION PER COLORADO r i I -� ISSUE STATE LAW, NFPA 720 AND VFES REQUIREMENTS. 7 FIRE ALARM FACTORY l II 5. EACH TOWNHOUSE UNIT SHALL HAVE A DEDICATED FIRE INSTALL DRAWINGS ALARM CONTROL PANEL TO SUPERVISE SMOKE AND CO L = © BEDROOM2 DETECTORS AS WELL AS THE FIRE SPRINKLER SYSTEM. I l I FROM SB KI CHEN BELOW II KEY PLAN 1 / 6. SMOKE DETECTORS MUST BE INSTALLED AT LEAST 3' AWAY L I ATH — — — - LAUNDRY FROM CEILING FAN BLADES. L L H I Y 7. FIRE ALARM SYSTEM INSTALLATION WILL OCCUR ON SITE IN L I VAIL. MODULAR CONSTRUCTION WILL INCLUDE BOXES AND I I PATHWAYS. , �. RI L CLOSET I �L T TO ABOVE �- -� �ppp WATER ENTRY 2 CAR GARAGE DINING BATH o ©SB CO 0 CLOSET L` �r� / . SHEET TITLE CLOSET UNIT 3.2 A FIRE ALARM MECH BOIL OSB CC #18-6 TO BOVE 1 d WIRE, _ I�'� TYPICAL KJZ t 1 SB/CO co ENTRY LIVING MASTER REVISION EIJ _ BEDROOM BEDROOM 11. o, 0 o m o� ° FROM K - I L BELOW ©SB MASTER BATH e. z \ 1_,, IU — EP et I ❑ ❑ ci r 61 Ti d E 3 O O 0 d N N d N 7 4 UNIT 3.2 A - LEVEL 01 - FLOOR PLANUNIT 3.2 A - LEVEL 02 - FLOOR PLAN UNIT 3.2 A - LEVEL 03 - FLOOR PLAN [PROJECT NUMBER PROJECT NUMBER 1/4" = 1'-0" 1 1/4" = 1'-0" 1 1/4" = 1'-0" ISSUE DATE JULY 13,2017 2 d r SHEET NO. r v N \ OTE: FLOOPLA\ S 0 \ LOWER POTIO \ OF DAWI \ G ILLUSTRATE DEVICE LOCATIO \ S A\ 3 WRI \ G . CPS N FA3.04 N PLANS 0 \ UPPER POTIO \ OF DAWI \ G ILLUSTRATE 3OX LOCATIO \ S DINE\ SIO \ ED TO THE 'CP . N