Loading...
HomeMy WebLinkAboutA17-0048_FA3.05_1506356580.pdf Z; di11111 IA el X '5'3 5.2iiiji o Vail Fire&Emergency Services 09/25/17 IF i -0I ff i Ty BEDROOM 2 TOWN STAMP DEN/SUNROOM DINING MIN 3'— I WATER ENTRY 0 I - 359 0 I SB111 LO IIIICLO T ' 69" iv I MIN 3' -I It II BEDROOM 1 LINEN I4'10" D E S I N 0 0 ,..,SB I 1 0 I OSB /CO 1 I HALLWAY I 0I 1 - J L 1 Li- I KITCHEN 1 I I 0 I 0 — i LAUNDRY BATH I 0 1 0 I I C 0 I I I DISCIPLINE STAMP I 2 CAR GARAGE 0 MASTER IL 0 CLOSET FIRE ALARM LEGEND: I I I 7 - 7 3» — s6 SYMBOL DEVICE DESCRIPTION I 0 J - J 0 ° 2'8" FACP Fire Alarm Control Panel 4" •. ARE MECH f 0 _ 0 x-1,8» ENTRY EL; «BOX, — TIP AL 1 KEY _ • Fire Alarm Keypad/Annunciator SB/CO o ' 0 0 SB/CO MASTER BATH i 4 '---6--' Sprinkler Waterflow Switch 4 8 LIVING • a POWDER rT, Sprinkler Valve Tamper Switch 0 ® 0 0 CLOSET MASTER �� �� II BEDROOM J 0 S Smoke Detector w/Sounder Base 7 l'�' N' !EL d = u J U 0 _ Multisensor Device, Smoke & — OSB/CO Carbon Monoxide Detector w/Sounder Base c Z UNIT 3L.2 A - LEVEL 01 - RCP _ _ - - 0 2 UNIT 3L.2 A LEVEL 02 RCP UNIT 3L.2 ALEVEL 03RCP 1/4" = l'-0" 2 2 1/4" = 1'-0" 2 1/4" = 1'-0" a FIRE ALARM NOTES: _ 1 . FIRE ALARM SYSTEM SHALL BE DESIGNED PER NFPA 72 AND VAIL FIRE & EMERGENCY SERVICES REQUIREMENTS. 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND .❑ I 'i' ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE LOCATIONS, ! ILI SYSETM DESIGN AND INSTALLATION. - DEN/ SUNROOM - CI.O CI.O 3. ALL DETECTORS WITHIN A SINGLE UNIT SHALL ACTIVATEWATER ENTRY ISSUE TOGETHER UPON A LOCAL ALARM WITHIN THE UNIT. #18-6 FIRE ALARM FACTORY 4. PROVIDE CARBON MONOXIDE DETECTION PER COLORADO DINING SB f WIRE, STATE LAW, NFPA 720 AND VFES REQUIREMENTS. a_ �-, t- TYPICAL INSTALL DRAWINGS o \ 5. EACH TOWNHOUSE UNIT SHALL HAVE A DEDICATED FIRE __ BEDROOM 1 BEDROOM 2 KEY PLAN ALARM CONTROL PANEL TO SUPERVISE SMOKE AND CO 4 I rI , DETECTORS AS WELL AS THE FIRE SPRINKLER SYSTEM. -E7T7T7 I 1=1 ch I W o P LINEN 6. SMOKE DETECTORS MUST BE INSTALLED AT LEAST 3' AWAY HTl co CD FROM CEILING FAN BLADES. I ii 1 TrI \ I h SB 7. FIRE ALARM SYSTEM INSTALLATION WILL OCCUR ON SITE IN -� ' VAIL. MODULAR CONSTRUCTION WILL INCLUDE BOXES AND I ©S: \• �. t PATHWAYS. I II HALLWAY / III II III z—±—�—� BATH 1 0 I I o SHEET TITLE II 1 —o � I -- II KITCHEN 0 C UNIT 3L.2A - FIRE 1 I MASTER — —I ALARM T CLOSET 2 CAR GARAGE LAUNDRYC c n 1 d UP FROM � SB REVISION H TO ABOVE MECH BELOW TO ABOVE 7 , 0I C o) �J FROM ©SB/CO EA- T BELOW x UP ©SVCO L� z LIVING 0 _ T IL rj if 9 dCLOSET h MASTER BATH MASTER E ENTRY ut BEDROOM m o o E o J POWDER z- L I D L_ F W d N g 4 UNIT 3L.2 A - LEVEL 01 - FLOOR PLANUNIT 3L.2 A - LEVEL 02 - FLOOR PLAN UNIT 3L.2 A - LEVEL 03 - FLOOR PLAN [PROJECT NUMBER PROJECT NUMBER I 1/4" = 1'-0" 1 1/4" = 1'-0" 1 1/4" = 1'-0" ISSUE DATE JULY 13,2017 2 S. r SHEET NO. r v \ OTE: FLOOPLA\ S ON LOWED POTIO \ OF DAWI \ G ILLUSTRATE DEVICE LOCATIO \ S A\ 9 WIRI \ G . SCP N PLA\ S 0 \ UPPED POTIO \ OF DAWI \ G ILLUSTRATE 30X LOCATIO \ S DIVENSIO \ ED TO THE RCP . FA3.05 N