Loading...
HomeMy WebLinkAboutA17-0055_Cut sheets_1505178780.pdf Security Concord 4 Overview Concord'4 is a full-featured security system for residential and Macro keys(available only on ATP 2100 and ATP 2600touchpads) commercial intrusion as well as residential fire detection that complies simplify system operation.Pressing a single button performs a system with false alarm standards.Easy to install and simple to use,Concord's command,eliminating the need to enter in an entire command modular design and advanced software provide outstanding system string.Each of the four macro buttons on these touchpads can be flexibility to meet the needs of virtually any residential or commercial programmed to perform one system command per partition.System security application. commands up to 14 key presses can be programmed. High standards Macro keys con be used to create custom arming levels.For example, The panel comes standard with eight hardwire zone inputs,including a user might create an arming level that would automatically bypass a 2-wire smoke detector loop that can handle up to 20 detectors.A selected interior sensors to create a special"Night"mode setting. built-in RF receiver with 96-zone capacity(600-1021-95R only)provides instant compotibilty with the complete line of GE Security Learn Made Standard Features sensors.Two programmable outputs can be set up to activate external devices during an alarm or other system event. •Six partitions and eight built-in hardwire zones-96 zones maximum Easy expansion as either hardwire,wireless,or combination •96 wireless zones standard onboard 1600-1021-95R only) Expand Concord's capabilities by adding SuperBus®20008Z Input •Two onboard programmable outputs Modules for eight additional zones per module,or SuperBus 2000 •Compatible with all GE Security crystal and SAW Learn Mode sensors 4-Relay Output Modules to add four more output points.SnapCards" •SIA CP-01 False Alarm Reduction Standard compliant also add to system zone inputs and outputs.Each card lone per panel) •2-and 4-wire smoke detector compatibility connects easily to the panel circuit board inside the cabinet fora •Panel auxiliary power provides 1 amp clutter-free,professional installation.Increase RF coverage area by •Built-in 12-watt siren driver adding up to four SuperBus 2000 RF receivers or SuperBus 2000 RF transceivers.Each receiver supports all 96 zones. Expand the system even further with a Phone Interface/Voice Module Additional Features for on-and off-site system control using touch-tone phones.The •230 user-programmable access codes with programmable module includes a speaker output that provides on-site voice status authority levels and alarm messages. •Latchkey numeric paging with optional keychain touchpad activation Adding a SuperBus 2000 Energy Saver Module lets users control •Audio verification in partition 1 with VOX mode heating and air conditioning.The Power Line Carrier Power Transformer (requires Interrogator®200) adds X10 light control.The Wireless Gateway Module allows users to •250-event history buffer viewable from any alphanumeric keypad, control and monitor the status of the system from the Alarm.com Downloader,or automation device Web site. •Keyswitch arming using a hardwire or wireless zone Increase power capability for system peripherals with a SuperBus 2000 •Programmable on site using alphanumeric touchpads or off site 2-amp Power Supply Module with battery backup.The module provides using Enterprise 2 amps at 12 VDC. •Time and status displayed on all touchpads •16 schedules available for scheduled lighting and outputs Effortless programming Conduct quick and easy on-site programming with alphanumeric touchpads and a menu-driven text interface with shortcut menu numbers.A quick programming menu makes it even easier to install smaller,basic systems.For off-site programming,use Enterprise® downloader software(version 3.1 and later). Concord 4 Powerful, expandable security with Learn Voce technology (. E Security North America T888-GE-SECURITY Specifications 888-437-3287 Power super P Out uts Asia Required transformer Class 11,16.5 VAC,40 VA,60 Hz 12 VDC,1.0 A(max.combined 12VDC,4.5 Ah or 7Ah re- OUil/+12V)output 11 with auxiliarypower output) F 852-2142-5068 Backup battery chargeable,sealed,lead-acid 0UT2/OC(output 2) Open-colle ot 300 mA max F 852-2142-5063 _ 9 Battery backup time 24 hours(when fully charged. Regulated,current limited, Australia with appropriate external load) Auxiliary power output self-resetting 12 VDC:1.0A T 61-3-9239-1200 15 minutes under load every (max.combined with output 1) F 61-3-9239-1299 Batterytest 24 hours(every 4 hours for UL installations) Environmental Europe Transformer fuse Non-replaceable fuse 32 to 120°F Io to 49°C):up 132-2-725-11-20 Panel auxiliary Current-limited,1.0Amax. Operating temperature to 140°F(60°C)under F 32-2-721-40-47 voltage output @ 12 V DC temporary conditions Latin America Storage temperature -30 to 140°F1-34 to 60°C) Communication formats T 305-593-4301 DTMF or pulse with integrated Relative humidity 90%max.,noncondensing F 305-593-4300 Dialing line seizure relay www.gesecurity.com Formats suSIA Digital 111300 bps)or Physical Contact ID Dimensions(HxWxD) 14.0x 12.0x3.0 in.1356x305 Specifications subject to 3 central station phone x 76 mml change without notice. Capabilities numbers and 5 pager Weight 5 lb.,10 oz.12.5 kg) shone numbers Chassis material 0.048-in.11.2 mml 16 gauge ©2010 General Electric Company steel,punched and formed All Rights Reserved Inputs Color Beige 96 max.hardwire or wireless: 8 hardwire zones built in,96 Regulatory Input zones zone wireless capacity built in FCC Parts 15 and 68 (600-1021-95R only) UL985,UL 1023,UL 1635 Dotabus format SuperBus 2000 with UL 1610(600-1040 panel only), auto-enrolling capability cUL Databus capacity Up to 16 devices SIA CP-01 2000 False Alarm Prevention Ordering Information Concord 4 panels Touchpad options 600-1021-95R Concord 4 RF panel 60-597-95 HiTech handheld touchpad 600-1040 Concord 4 Commercial(does not include 96 zone 60-659-95R/60-B32- Crystal.SAW and encrypted Learn More keychain wireless receiver) 95R/60-606-319.5 touchpad Expansion options 60-746-01/60-803-04 SuperBus 2000 2x16 and 2x20 LCD alphanumeric 60-620-01 SuperBus 2000 energy saver module(ESMI touchpads 60-756 Combo input/output SnapCard 60-804-04 SuperBus 2000 2x20 vacuum fluorescent display 60-757 8Z hardwire input SnapCard alphanumeric touchpad 60-758 4-output SnapCard 60-820 SuperBus 2000 fixed display LCD touchpad 60-770 SuperBus 20004 output module 60-983 ATP1000 alphanumeric touchpad 60-774 SuperBus 2000 8Z input module 60-985/60-984 ATP2100 and ATP2600 alphanumeric touchpads 60-783-02 SuperBus 2000 automation module 600-1020 FTP1000 fixed english touchpad 60-777-01 SuperBus 2000 phone interface and voice module Transformer options SuperBus 2000 commercial transceiver module 600-1023 16.5 V,40 VA standard transformer,UL listed for 60-821-95 (compatible with crystal sensors and touchpads) U.S.applications 600-1053 SuperBus 2000 GSM module 600-1023-CN 16.5 V,40 VA standard transformer,cUUCSA listed 600-1019 SuperBus 20002.0 A power supply module for Canadian applications 600-1025-01-95R SuperBus 2000 transceiver module 600-1024 16.5 V,40 VA power line carrier transformer,UL -- --- ---- — --- --- -------- listed for U.S.applications 14 imagination at work 910-3243 2010/01 1601051 SYSTEM SENSOR- TM 14 Series Combination • CO/Photoelectric ct Smoke Detector Pt 4 Best-in-class carbon monoxide(CO)and smoke detection technology in a single, system-connected device. Features Integration:The i°Series combines CO and smoke detection • Single device for CO and smoke detection that uses less wiring into one device,requiring less wiring and fewer back boxes than and fewer junction boxes two separate devices.The i°Series is compatible with i'(2WiA-B or 4WTA-B),so an attractive CO monitoring solution can easily be • Compatible with a wide range of control panels with the use of the retrofitted into existing i3 installations.The i4 Series CO cell can be required i°Interface Module. easily replaced at end-of-life,resulting in a much lower life cost than • Sends distinct smoke and CO signals to the panel having to replace the entire detector. • Sounds Temporal 3 for smoke and Temporal 4 for CO Installation ease:The i°Series Combination CO/Smoke detector • Built-in 85dB sounder requires less wiring than two separate CO and smoke devices. • LEDs display both CO and smoke status Installers can pre-wire its plug-in base,while its large wire-entry port • External IR LED provides extended range sensitivity testing and in-line terminals provide ample room for neatly routing wiring.The base accommodates several back box options and also direct mounts • Versatile mounting allows for wall or ceiling placement using drywall anchors.The i4 head plugs into the base with a simple • Easily replaceable electrochemical CO cell with 6-year end-of-life Stop-Drop'N Lock"'action.When the detector's CO cell reaches end- timer that signals the panel and chirps to alert the homeowner of-life,it can be easily replaced in the field without a tool. • RealTest®enables functional test using canned CO Intelligence:With the help of the module,the i°Series transmits • Drift compensation and smoothing algorithms provide false distinct CO and smoke signals,allowing appropriate response alarm immunity from the central monitoring station.Intelligent features,such as drift • Compatible with SENS-RDR sensitivity tester compensation and smoothing algorithms, reduce nuisance alarms. • Full agency compliance with UL 268 and UL 2075 Instant inspection:The i°Series LEDs enable instant inspection of detector status signaling normal/standby condition,alarm condition,maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device.CO cell functionality can also be quickly validated in the field with canned CO per NEPA 720:2009 requirements using the Agency Listings detector's RealTest functionality. O LISTED r" PL S2E8 1E5302227 esco nation 00/Stn o Carbon monoxide(CO)/Smoke detector shall be a System Sensor model number COSMO-2W(2-Wire)/COSMO-4W(4-Wire)listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection.The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals.The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector's base shall be able to mount to a single-gang electrical box or direct(surface mount)to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide LED indication that blinks to indicate normal standby,smoke alarm,smoke maintenance.CO alarm,CO trouble/end-of-life.When the detector is in CO trouble condition,it shall send a trouble signal to the panel.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually.The detector shall have a replaceable CO cell that can be replaced at end of cell life. Operating Voltage(VDC): Nominal:12/24;Minimum:8.5;Maximum:35 Maximum Standby Current 50 pA Maximum Alarm Current: 2-Wire 50mA;4-Wire 40mA Audible Signal: 85 dBA Maximum Reverse Polarity Current: 20 mA Maximum Start-up Current: 200uA Maximum Start-up Capacitance: .10 pF PhysTmlApkcific%tiOnt. Dimension: Diameter:5.5";Depth:2.5"(includes base) Weight: 9.2 oz.(261 g) Operating Temperature Range: 0-50°C(32-122°F) Operating Humidity Range: 20-95%RH Storage Temperature Range: -10-70°C(14-158°F) Sensitivity: 2.5%/ft nominal Input Terminals: 14 to 22 AWG Mounting: Back boxes:3.5-and 4-Octagonal;Single-gang;4-Square;2 x 4 3.5"and 4"round ceiling. Direct mount to wall or ceiling. ppetiation:M040iLED-StAtiiplg Alarm Smoke: Off On Off Temp 3 Alarm CO: Off Off On Temp 4 Alarm Smoke&CO: Off On On Temp 3 Power Up: Blink 5 sec. Blink 5 sec Blink 5 sec. Off Standby: Blink 5 sec. Off Off Off RealTest°Mode(CO): Off Off Blink 1 sec. Off After CO is Sprayed: Off Off On Temp 4 Smoke Maintenance: Off Blink 5 sec. Off Off CO Trouble: Off Off Blink 5 sec. Off End-of-Life: Off Off Blink 5 sec. Intermittent i4 Series Interface and Reversing Relay Module Q The i4 Interface Module connects up to 12 detectors to a ® t Q wide range of control panels using only 2 to 3 zones. It also interconnects the devices, so when one device alarms, they all sound. Features Integration:The i'module allows up to 12 i°Series or compatible 13 Series smoke detector models to be integrated into a fire alarm • Easily integrates up to 12 compatible detectors to a wide range of control panels panel using only 2 to 3 zones:a smoke zone,a CO zone and an optional trouble zone. Detectors sound Temp 3 for smoke and Temp • 2-wire module is compatible with COSMO-2W combination 4 for CO events.The i4 module can be used to alarm all sounders in detectors and 2WTA-B smoke detectorscompatible detectors for smoke and CO events.When one detector • 4-wire module is compatible with COSMO-4W combination detects smoke or CO and goes into alarm,all connected detectors detectors and 4WTA-B smoke detectors. alarm,offering the highest level of warning to the homeowner. • Sends distinct smoke and CO signals from i°detectors to the panel Installation ease:The i°Series Interface Module mounts to a • LED indication shows when a detector on the loop requires 4',/16-inch square back box for quick and easy installation.Terminal cleaning or maintenance(2-wire detectors only) blocks with durable SEMS screws ensure a reliable connection. It • Initiates the EZ Walk loop test(2-wire detectors only) also has pre-drilled holes for easy mounting inside a metal enclosure • Module interconnects the sounders of all devices connected to it. Intelligence:The i°Interface Module allows i°and compatible i3 No RSS-MOD is required.Optional trigger inputs are provided to sound multiple modulessmoke detector models(2WTA-B and 4WTA-B)to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection:The i°Interface Module provides LED status indication for the loop,displaying normal operation,loop wiring fault, smoke events,smoke maintenance(2-wire only),CO events,and CO maintenance/end-of-life. Agency Listings LISTED S 11 :Gi3022B The i°module shall be a System Sensor 14 Series model number COSMOD2W(2-wire)or COSMOD4W(4-wire)listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems.The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws.The module shall provide 4 LED indicators that blink or illuminate to indicate communication status,maintenance alert,alarm or freeze trouble conditions,and EZ Walk loop test mode(2-wire module only).The module shall allow communication to 14 Series and i3 Series detectors with sounders with any UL 864-and UL 985-listed lire alarm control panel capable of utilizing this module.The 2-wire module shall offer provisions for Style D/Class A wiring on IDC loops and shall provide a loop testing capability(EZ Walk)to verify the initiating loop wiring. Operating Voltage(VDC): Nom.:12/24;Min.:8.5(2-wire), 10(4-wire,power limited);Max.:35 VDC(power limited) Standby Current: 2-Wire:61mA(max.),45mA(12V In),26mA(24V In)}, 4-Wire:52mA'(max.),37mA'(12V In),22mA'(24V In) Alarm Current': 2-Wire: 181mA(max.), 121mA(12V In),64mA(24V In), 4-Wire:78mA'(max.),57mA'(12V In),34mA'(24V In) Maximum Ripple Voltage: 30%of applied power Maximum Alarm Threshold: 9.2 Volts DC Alarm and Maintenance Contact Rating: 100 mA®36 Volts DC,resistive,25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms;4-Wire 300 Ohms Trigger inputs: Min On Voltage: 1.5V;Max.:Vin 'Does not include current draw from attached deleclors or EOL relay 3 Does not include reverse polarity current draw trom attached0-50°C(P_hysid .gam e. Dimension: Height:6.04";Width:6.04 Depth: 1.00" Weight: 9.6 oz.272(g) Operating Temperature Range: 0-50°C(32-122°F) Operating Humidity Range: 5-95%RH Storage Temperature Range: -20-70°C(-4- 158°F) Input Terminals: 14 to 22 AWG Mounting: 4"/1e"square back box or inside a metal enclosure Alarm Smoke: Blink 1 sec. Off On Off Alarm CO: Blink 1 sec. Off Off On Alarm Smoke&CO: Blink 1 sec. Off On On No power/No communication: Off Off Off Off Loop wiring fault: Blink 1 sec. On Off Off EZ Walk Test Mode(2-wire only): Blink 1 sec. Blink 5 sec. Off Off Smoke Maintenance(2-wire only): Blink 1 sec. Off Blink 5 sec. Off Smoke Freeze Trouble(P 2WTA-B only): Blink 1 sec. Off Blink 10 sec. Off CO Trouble: Blink 1 sec. Off Off Blink5 sec. Module Power-Up Sequence/LED Status Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Ordering Information COSMO-2W 12/24 volt,2-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt,4-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module(required to use with COSMO-2W models) COSMOD4W 4-wire interface module(required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay(required with 4-wire systems) SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 13s, . Phone.800-SwENSOsysteR2m•sensorcom Fax.630-377-6495 pro,jci 1 " ° - wwGOC '^P 1113 -Ma SYSTEM CT SENSOR s"c t ✓ r� S Smoke Detectors with s� Sounder and Relay Option System Sensor if sounder and relay smoke detectors apply the guiding principles of installation ease, _ '3 intelligence,and instant inspection in a series of specialty conventional devices. Features Installation ease.Throug hout the i3 series,installation is simple •85 d8 sounder with its installer-friendly base and plug-in design.The base accommodates a broad range of back box and direct mounting •Form C relay options and provides ample space for pre-wiring the device.To •Isolated thermal sensor complete the installation,the P detector plugs into its base with a simple Stop-Drop IN Lock action. •Plug-in design(base included) •In-line terminals Intelligence.To reduce the likelihood of nuisance alarms,all i3 detectors are equipped with both drift compensation and •Flexible mounting options smoothing algorithms.These capabilities minimize both short-and •Stop-Drop'N Lock'"attachment to the base long-term causes of nuisance alarms,such as RF interference and dust accumulation.When connected to the 2W-MOD2 loop test/ •Removable cover and chamber maintenance module or an P Ready`panel,2-wire i3 detectors can •Remote maintenance signaling generate a remote maintenance signal when in a maintenance or freeze trouble condition.To measure the sensitivity of any i3 detector, •Drift compensation and smoothing algorithms the SENS-RDR displays the reading,in terms of percent-per-foot obscuration,within seconds. •Simplified sensitivity measurement •Dual-color LEDs Instant inspection.i3 has red and green LEDs to simplify local status indication during power-up,standby,alarm,maintenance, and freeze trouble conditions.When in alarm,P sounder models generate an 85 dB temporal tone.If connected to the RRS-MOD reversing relay/synchronization module,all i3 sounders on the loop will activate when one detector is in alarm.The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal. Agency Listings Should the application call for differentiating between a local and a general alarm,the P line offers an isolated thermal model,which �MEA MSFM initiates a local alarm when smoke is detected,and a general alarm LISTED 41:* ®`� approved approved ° �°s when the thermal sensor is activated. 5911 3013193 ]n2-1653164 312-02£ 2133 3197.033 ib Smoke Detector Specifications sethotskgpabmmsssssssssgsssgssssssssassssssssssw.. iiammtkevismininissosinivismitimimpsissiginallitalli Operating Voltage Nominal:12/24Vnon-polarized LED Mode Green LED Red LED Condition Duration 2-wire:8.5 V to 35 V Prover up Blinkevery Blinkevery l0 Initial LED 80 seconds 4-wire:10V to 35 V 10 seconds seconds status Maximum Ripple Voltage 3096 of applied voltage(peak to peak) indication Standby Current 2-wire:50 pA maximum average Normal Blink every 5 off 4-wire:50 pA maximum average (standby) seconds Peak Standby Current 2-wire:100 pA Out of off Blink every 4-wire:n/a sensitivity seconds Maximum Alarm Current 2-wire:2WTR-B:130 mA limited by control Freeze off Blink every 10 panel trouble seconds 2WTA-B:130 mA"* Alarm off Solid 4-wire:4WTA-B,4WTR-B:35 mA Q n .a gainignigunisigias 4WTAR-B,4WITAR-B:50 mA *"Direct Power(Non-Reverse Polarity).130 Condition Duration mA limited by panel.Reverse Polarity Power Initial LED 80 seconds 30 mA for the 2WTA-B in alarm;12 mA for all status other 2WTA-B units on the loop.Add 25 mA indication for the RRS-MOD reversing relay alarm current wohlmogiligido§tigoofigoiminigimmissisimils111111111111111 Alarm Contact Ratings 2-wire:n/a Smoke detector shall be a System Sensor it Series model number_ 4-wire:05 A@ 30V AC/DC listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Form C Contact Ratings 2A@ 30VAC/DC Systems.The detector shall be a combination photoelectric/thermal ti equipped with a sounder(model 2WTA-B,4WTA-B),a Form C relay(model 2WTR-B),a combination sounder/relay(model 4WTAR-B),or an isolated Operating Temperature 32°F to 100°F(0°C to 37.8°C) thermal/sounder/relay(model 4WITAR-B).The detector shall include a Range mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang, Operating Humidity 0 to 9596 RH non-condensing and 4-inch square back boxes with a plaster ring,or direct mount to the Range ceiling using drywall anchors.Wiring connections shall be made by means Thermal Sensor 135°F(57.2°C)fixed of SEMS screws.The detector shall allow pre-wiring of the base and the Freeze Trouble 41°F(5°C) head shall bea plug-in type.The detector shall haveanominal sensitivity Sensitivity 2.596/ft.nominal of2.5 percent per foot as measured in the UL smoke box.The detector Input Terminals 14-22 AWG shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- Dimensions(including 5.3 inches(134mm)diameter,2.0 inches color LED indication that blinks to indicate power-up,normal standby,out of base) (51 mm)height sensitivity,alarm,and freeze trouble conditions.When used in conjunction Approximate Weight 7.1 oz(200 g) with the 2W-MOD2 module,2-wire models shall include a maintenance Sound Pressure Output 85 dBA(models 2WTA-B,4WTA-B,4WTAR-B, signal to indicate the need for maintenance at the alarm control panel and and 4W RAR-B only) shall provide a loop testing capability to verify the circuit without testing each Mounting ark-inch octagonal back box,4-inch octagonal detector individually.When used in conjunction with the RRS-MOD module, back box,single-gang backbox,4-inch square all P sounder models on a loop shall sound when one sounder alarms,all shall back box withaplaster ring,direct mount to be synchronized,and all sounders may be silenced from the panel. ceiling Ordering Information sgsg§toppossitsgsmaggisiggsgasgsgsseggsgspg 1411.10,§111111111111140,014101111111.11311111.11111111111111111,11,111.1111111.1.1 2WTA-B Yes 2-wire 130 mA max.limited by RRS-MOD Reversing relay/synchronization module control panel 2W-MOD2 2-wire loop test/maintenance module 2WTR-B Yes 2-wire 130 mA max,limited by SENS-RDR Sensitivity reader control panel RT Removal/replacement tool 4WTA-B Yes 4-wire 35 mA A77-AB2 Retrofit adapter bracket 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA K' 3825 Ohio Avenue•St.Charles,IL 60174 m�uc„ cows Mamsenm,. peunun.:ns.upmu009 SolemSemor c_w,nsynems:+u-tomrx Phone:800-SEN5OR2•Fax:630-377-6495 c ricnt pOducunternation,InducingteJa0.4wtondrosdat mm, AM03=8404.Mr.P2170