Loading...
HomeMy WebLinkAboutGentex Photoelectric System Smoke Detector GENTEX CORPORATION Photoelectric System 8000 / Smoke Detector 8003 Applications The Gentex 8000/8003 Series of photoelectric smoke detectors are SERIES designed for commercial, industrial, residential and institutional applications. The 8000/8003 is engineered to provide outstanding performance wherever reliable fire protection is required. The Gentex 8000/8003 Series provides an exclusive patented three • position test feature that simulates a 0.85%and a 3.5%actual smoke I1I1I1l condition, in full compliance with ANSI/UL 268 Standards for installation I'IIIII per NFPA 72 and the International Codes (IBC/IFC/IRC).The test feature I has the capability to let you know when maintenance is required. • A standard Form A dry relay contact for connection to the system initiating _ circuit and an auxiliary Form C dry relay contact is provided on all models for use as remote annunciation as a releasing device. Other options include reverse/local 90dBA solid-state piezo horns and 135°F (57.2°C) fixed temperature self-restoring integral or isolated thermals to meet your specific requirements. Easy Wash®- The 8003 Series provides the temporal 3 evacuation tone as a standard On Site feature.When testing the 8003 Series it may take up to 16 seconds longer '' Maintenance to go in or out of alarm. Program Standard Features Product Listings • Available in 120VAC and 24VDC SIGNALING • Listed for releasing device service • • Horn frequency 3100 Hz (nominal) • Temporal 3 evacuation sounding device (8003 Series) LISTED • Patented three position test • Nominal 2.5% sensitivity • ANSI/UL 268 Listed • Easy Wash®on-site maintenance washing program • CSFM:7272-0569:102 • Form A/Form C dry relay contacts • MEA#928-84-SA • Quick-disconnect wiring harness • MSFM Listing#1929 • 5-to-1 signal-to-noise ratio • Pulsing LED sensing chamber Product Compliance • Fully insect screened • NFPA 72 • Solid-state LED condition indicator • IBC/IFC/IRC • Mounting hardware adapts to standard junction boxes • Quality Management System is certified to: • Dust cover to prevent contamination during installation ISO 9001:2008 • Protective high air velocity gasket • 24 month warranty from date of purchase MEMBER ASSEMBLED IN THE LISA 8000 (8240/8100) Series - Solid State Piezo Sounder (P Models only) Reverse/ Model Part Integral 135°F Isolated 135°F Non-Latching Number Number Voltage Local 90dBA Thermal Thermal Circuit"Y" Piezo 8240 908-1201-002 24VDC 8240Y 908-1207-002 24VDC • 8240T 908-1203-002 24VDC • 8240P 908-1202-002 24VDC • 8240PT 908-1205-002 24VDC • • 8240PTY 908-1209-002 24VDC • • • 8240PY 908-1208-002 24VDC • • 8240PH 908-1206-002 24VDC • • 8240PHY 908-1210-002 24VDC • • • 8100 908-1233-002 120VAC 8100Y 908-1239-002 120VAC • 8100T 908-1234-002 120VAC • 8100P 908-1236-002 120VAC • (local) 8100PY 908-1240-002 120VAC • (local) • 8003 (8243/8103) Series - Temporal 3 Piezo Sounder (P Models only) Reverse/ Model Part Integral 135°F Isolated 135°F Non-Latching Number Number Voltage Local 90dBA Thermal Thermal Circuit"Y" Piezo 8243P 908-1211-002 24VDC • 8243PT 908-1212-002 24VDC • • 8243PTY 908-1215-002 24VDC • • • 8243PY 908-1214-002 24VDC • • 8243PH 908-1213-002 24VDC • • 8243PHY 908-1216-002 24VDC • • • 8103P 908-1243-002 120VAC • (local) 8103PY 908-1246-002 120VAC • (local) • NOTES • The 8000/8003 Series are round units. • When testing 8103P/8243P Series, it may take up to 16 seconds longer for smoke alarm to go in or out of alarm mode. • It is recommended that 8000/8003 Series smoke detector be tested monthly. • Refer to Technical Bulletin 002 for Easy Wash°on site washing instructions • 8100P/8240P units produce a non-temporal audible alarm and are therefore not intended for locations where the desired action of the occupant(s) is evacuation. • 8103P/8243P units produce a temporal 3 audible alarm. Per NFPA 72, the American National Standard Audible Emergency Evacuation Signal as defined In ANSI S3.41, is required whenever the intended response is to evacuate the building. Wiring for Releasing Device Service Normally Closed Configuration Normally Open Configuration 120 VAC 120 VAC POWER SUPPLY POWER SUPPLY WHITE WHITE BLACK WHITE BLACK I NOTE:The blue wire � YELLOW must be I • BLUE WHITESMOKE DETECTOR ORANGE capped off ORANGE SMOKE DETECTOR when wiring • for closed BLACK I BLACK contacts. YELLOW • BL •WHITE UE • WHITE SMOKE ORANGE • .WHITE SMOKE • ORANGE • .WHITE DETECTOR DETECTOR BLACK BLACK —0 BLACK �— BLACK • • •• • • •• RELEASE RELEASE RELEASE RELEASE DEVICE I DEVICE 2 DEVICE I DEVICE 2 Detector Wiring Diagram For "H" — Isolated Thermal — — NOTE:Supervision of - - power is necessary and is POSITIVE 3 POSITIVE 3 / accomplished by installing II-- POWER NOTE: ` POWER an End of Line Relay As- NEGATIVE 12 IN �� NEGATIVE 12 / IN sembly.The EOL Relay 12OVAC C` Assembly contacts are POSITIVE 6 POSITIVE 6 closed when energized / POWER (8100 & 8103) < and are wired in series NEGATIVE 15 OUT ~- POWER with the alarm loop.Power / Hot(Black)Wire: NEGATIVE 15< ....4OUT failure or a break in the VIOLET 10 Pin 3& Pin 6 power loop de-energizes the EOL Relay,causing VIOLET 13 , Neutral VIOLET 10 / the relay contacts to open. 1 ALARM White Wire: C` / This results in a trouble VIO/BLK 1 CONTACTS (White) VIOLET 13/ signal at the control panel. VIO/BLK 4 Pin 12&Pin 15 c` ALARM 24VDC VIO/BLK 1 CONTACTS BLUE 7 T �. (8240 & 8243) VIO/BLK 4< , I ORANGE 8 , AALLACRMSORY Positive YELLOW 9 CONTACTS (Red)Wire: BLUE 7 < BROWN 2 Pin 3& Pin 6 ORANGE 8ACCESSORY ALARM BROWN 5 , Negative YELLOW 9 ` CONTACTS GRAY 11 I I HEAT (Black)Wire: - - T SENSOR Pin 12&Pin 15 GRAY 14 ,� __ PLUG DETECTOR PLUG DETECTOR Supervised Wiring Diagrams SINGLE LOOP PANEL FUNCTIONAL DIAGRAM POWER rSHOWN 1 DOUBLE LOOP PANEL FUNCTIONAL DIAGRAM POWER rSHOWN BPW LENERGIZED SpWy LENERGIZED FIRST LAST RELAY MODULE FIRST LAST RELAY MODULE UL LISTED SMOKE SMOKE UL LISTED SMOKE SMOKE CONTROL DETECTOR DETECTOR CONTROL DETECTOR DETECTOR PANEL RED IN OUT RED I O T RED PANEL RED IN OUT RED IN 06T RED POWER. �I WO BLK •�� L POWERO BLK O O BLK O O BLK pig ALARM: RENNIN VIOL 101. - ALARM, VIOL O O VIOL VIOL LOOP VIO/BLK BOWVIO/BLKMid VIO/BLK �� L LOOP O VIO/BLK a i o VIO/BLK O • o VIO/BLK END OF LINE BLU BLU ORN ACCESSORY • : .LU RESISTOR LOOP C� ORN 'ACCESSORY Ala YEL'LONTACTS . TEL RETURN O TEL'CON ACTS ALARM I' O TEL DC[*BLK DC DM 11 AC[WHTHNEUT] AC[WHT NEUT] 8000 / 8003 SERIES Electrical Specifications Model Numbers 8240 8100 Operating Voltage Nominal: 24VDC 120VAC Range Min: 18VDC 110VAC Max: 30VDC 130VAC Frequency — 60HZ Current Consumption at Nominal Operating Voltage(Milliamperes): Standby 6mA 70mA Alarm 60mA 70mA Note:For"P"Option (Horn),Alarm Current Consumption is unchanged. Sensitivity 2.5%Nominal Alarm Contacts 1 Form A—N.O.(Resistive) 1 Amp at 24 VDC 0.6A at 120 VAC Auxiliary 1 Form C—N.O.(Resistive) 1 Amp at 24 VDC 0.6A at 120 VAC Temperature 40°- 100°F(4.4°-38°C) Humidity 10%-93%Relative Humidity Size Diameter at base:5.75 in.(14.605 cm) Overall diameter: 6.25 in.(16.51 cm) Depth:2.625 in. Architect & Engineering Specifications The photoelectric smoke detector shall be a Gentex Model 8100/8103/8240/8243 or approved equal and shall operate on the photoelectric light scattering principle and shall be listed by Underwriter's Laboratories, Inc.,the State of California Fire Marshal and the Bureau of Standards and Appeals(NYC). The smoke detector shall contain an infrared LED light source and a light sensing photodiode.These components shall be positioned such that when smoke particles enter the sensing area,light from the LED reflects onto the photodiode.When the amount of light reflected onto the photodiode reaches a predetermined level,the detector shall latch into alarm. The smoke detector shall contain a test knob that,when in TEST 2 Position,scatters the detector's LED light source to the equivalent of a nominal.85%actual smoke condition,when in TEST 1 position the detector shall simulate an equivalent of a nominal 3.5%actual smoke condition.Test feature shall indicate when maintenance is required without the need of additional equipment. A magnetic switch closure or other switch closure,or smoke generating equipment which does not scatter the light beam or test sensitivity is not sufficient. The smoke detector shall be able to contain an optional internal 90dBA horn(at 10 feet)which emits an intermittent tone when the detector alarms.Also have the provision of reverse polarity operation.The horn shall have the capability of being self-restoring. The smoke detector shall be able to provide a self-restoring integral/isolated heat sensor set to alarm at 135°F(57.2°C)fixed temperature. The smoke detector shall be provided from the manufacturer with all internal wiring(power in,power out and alarm contacts have 2 wires, auxiliary relay contacts each have 1 wire) leading into a plug-in terminal socket for ease of field installation.Screws are not acceptable since they make service more difficult.The manufacturer shall further supply the field wiring harness with plug connector for connection to insulated wire connectors. The smoke detector shall mount to a 2"x 3"switch box or 4"octagon junction box using a standard bracket that does not have to be purchased separately.The smoke detector shall be listed for wall or ceiling mounting. 24 units per carton 32 pounds per carton Important Notice: 551-0039-03 G E IV T E X These materials have been prepared by Gentex Corporation("Genres")for informational pur- poses only,are necessarily summary,and are not purported to serve as legal advice and should not be used as such.Gentex makes no representations and warranties,express or implied,that CORPORATION these materials are complete and accurate,up-to-date,or in compliance with all relevant local, state and federal laws,regulations and rules.The materials do not address all legal considera- tions as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and Fire Protection Products Group•www.gentex.com the application of such laws,regulations and rules to particular fact patterns.Eachperson'sactiv- ities can differently affect the obligations that exist under applicable laws,regulations or rules. 10985 Chicago Drive •Zeeland, Michigan 49464 Therefore,these materials should be used only(or informational purposes and should not be ubstieing sal legal ie. ewb 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax actiousednas ora failuresto acttutefor in sereliaknceprofesupon the ioninformatioadvn ccontainedGentinx thisill mnotateerial.responsible for any Gentex Corporation reserves the right to make changes to the product data sheet at their discretion.