Loading...
HomeMy WebLinkAboutB14-0240_10.28.14 - Engineered Review - Test & Balance report - phase 2,3_1414529340.pdf ____., , . . . 1 1 al1tC1 sesr,HG.AGdusTI*O AND OA AHG1HO St1REAU THE PROfESSIONAL'S CHOICE" IIa 11rEBB Certification # 3235 JEDI Balancing, Inc. Certifcation#BB009025C 568 Briggs Street P.Q. Box 525 Erie, CO. 80516 Phone(720) 839-5333 Website: www.jedibalancing.com Certified Test; Adjust; & Balance Report Project Vail Valley Medical Center—Phase 1 Address 181 West Meadow Dr. Vail, CO Architect Heery Design Mechanical Engineer Cator Rurna&Associates,Co. Contractor RK Mechanical Balancing Supervisors Don Pittser&Greg Barnes Date October 27, 2014 Job Number 2014-4894 p ,racE g a..A.No land Bryan 4 n.1"1 ''S Dames --. "'S •,k,knil <'' 9 Wires 144Z W1.0 1:15 12.4;t3 itTZ GREGOwr a awn iw7zs ,,,, i Not valid lams a Sipr►ba r xs VOW Un�as - -.w % a Exp.Srrdtl7B is ... t'37f201 •� •,w!! 't 7201 ,r` � Ir''ira int 1 iti3 TB3 Orsr "' aisi i C�r3 �� (_ TM 'fM�f 1� y$ a1 MIEM ll 2Wa" ��, *�r 71r� Kd�cwT'9✓.MI TABB Technician TABB Technician TABU Technician TABB Technician Nantes Gregory Rxrxses Nimes amber.Roomer,o Mourietjaisoo terse Ham=Va.bau Smith 11.1311 ID:90105792W IABIB uch gr61049506T was JDt aava494697 14.11 3 I.ns9 f 1is,,a Expiration llttitflawn Itc.e 22131/Ze1S �'ors 12!31!21135 r - A2131,2015 WI tbeParat9axxa#t=12!31/2014 Instrumentation: Digital Manometer Alnor Balometer EBT-721 Flowhood Alnor Balometer EBT-72 I Digital Pressure Gage Alnor Hydronic Manometer HM-680 Tachometer DT-36M Digital Volt-Amp Meter Fluke 335 Thermometer Alnor Balometer EBT-721 Method of Balancing: Supply, Return and Exhaust diffusers, grilles and registers were measured with an Alnor Balometer EBT-721. Heating and Chilled water flow rates were measured with an Alnor Hydronic Manometer HM-680 connected to the installed flow meters. Warranty Information: This project was completed according to NEBB Procedural Standards. The data presented in this report is a record of system measurements and final adjustments that have been obtained in accordance with the current edition of the NEBB Procedural Standards for testing, adjusting, and balancing environmental systems. Any variances from design quantities,which exceed NEBB tolerances, are noted in the Test-Adjust-Balance Report Project Summary. If a Test-Adjust-Balance Report Project Summary is not issued directly following this cover page, all measurements met the design requirements as specified by the design mechanical engineer. This project has a one-year guarantee on all Testing, Adjusting& Balancing from the date listed on this cover page. NoNo , Esrcoption t�� It;«aka Corrections Noted C. ❑ Revise and Resu1 irai Emil SPiad+tieci Item p Don Pittser nHECKING IS ONLY FOR GElYEFi CEO c r of THE P cr ER LIAL I wiry rim H NEBB Supervisor ro aci roTHE ONTR y # N �rjr•- }=Ec�>cA ,. THF r Aloe Fh,,rC AThJ r YJNTRACTO rS HE 5PO?S 3LE FOR OJMEM.S;GN. ,;t�vicA COMtPP Mal AND CO±4gE� AT TFIE JQB SITE ' PROCESSES AId TECs-mOt±Ey of CprySTRtlCTIGW, „��l'it4T (w Hts Wt'Rk WITH THAT of AZL OTHg� UCT/E5. sr O] r AC TO Y P6RFORAT of HtS rrEl-• GATOR,IRI NA d A C TES. co C Illus nq ectnpl Engneo, 2V282 . LL 7CS ORQUANTrrrEs !I APE I i w TESTNO,AII313STING BALANCINO SLIREAII ma a THE PROFESSIONAL'S CHOICE.' JEDI Balancing, Inc. 568 Briggs Street P.O. Box 525 Erie, CO. 80516 NEBB Certification # 323 Phone (720) 839-5333 Certification#BB009025C Web www.jedibalancing.com ABBREVIATION INDEX AHU: Air Handling Unit Motor FLA: Full Load Amperage RTU: Roof Top Unit S.F.: Service Factor MAU: Make Up Air Unit P.F.: Power Factor FCU: Fan Coil Unit Nom. Eff.: Nominal Efficiency CRAC: Computer Room Air Conditioning Unit RPM: Revolutions per Minute VAV:Variable Air Volume TI: Terminal 1 K Factor: Correction Factor T2: Terminal 2 FPB: Fan Powered Box T3: Terminal 3 AK: Area Correction OD: Outside Diameter CUH: Cabinet Unit Heater UH: Unit Heater ERV: Energy Recovery Ventilator TDH: Total Dynamic Head ERU: Energy Recovery Unit PSI: Pounds per Square Inch EF: Exhaust Fan BV: Balance Valve KEF: Kitchen Exhaust Fan CS: Circuit Setter SF: Supply Fan Valve D.P.: Discharge Pressure RF: Return Fan Valve S.P.: Suction Pressure TF:Transfer Fan Diff.: Differential SEF: Smoke Exhaust Fan Design D.P.: Design Differential Pressure SPF: Stairwell Pressurization Fan Actual D.P.: Recorded Differential Pressure SP: Static Pressure Ind.Imp.Dia.Indicated Impeller Diameter TSP:Total Static Pressure in.wc: Inches Water Column ESP: External Static Pressure HW: Heating Water VP:Velocity Pressure CHW: Cooling Water SA: Supply Air CW: Condenser Water RA: Return Air HX: Heat Exchanger OSA: Outside Air DX: Direct Expansion OA: Outside Air EAT: Entering Air Temperature MA: Mixed Air LAT: Leaving Air Temperature SD: Supply Diffuser EWT: Entering Water Temperature CD: Ceiling Diffuser LWT: Leaving Water Temperature SWD: Sidewall Diffuser ER: Exhaust Register MVD: Manual Volume Damper RG: Return Grille OBD: Opposed Blade Damper CFM: Cubic Feet Per Minute NAC:No Access FPM: Feet Per Minute NG: Not Given NIC: Not in Contract E: Existing ,s .. : ■ ■ "� .T.w� TE571NG,AOJVSTING Alio BALANCING evR EAU la '9 THE PROFESSIONAL'S CHOICE' JEDI Balancing, Inc. 568 Briggs Street P.O. Box 525 Erie, CO. 80516 NEBB Certification#323 Phone (720) 839-5333 Cert jication#BB009O25C Web www.jedibaiancing.corn GENERAL NOTES SEE ALL FIELD NOTES LOCATED BELOW EQUIPMENT DATA r ///x\ 4,i/Eill a.�°.µ0. B3 es f BAL4NC72VG ..V. #3235 #B9009025C Air Handling Unit PROJECT:VAIL VALLEY MEDICAL CENTER DATE: 10127/2014 LOCATION:VAIL,CO CONTACT:Trevor Quain PROJECT#: AUTHOR: SYSTEM/UNIT:E-AHU--SF-05 AREA: * Notes SYSTEM/UNIT:EAHU-SF 051 VAV 203 Tested By: Keenan Dubord AREA: Test Date: October 25, 2014 Unit Data VAV Address 5 Box Inlet Size 8 K Factor 2.0 Test Data Max Design CFM 230 CFM Max Actual CFM 225 CFM Min Design CFM -CFM Reheat Design CFM 230 CFM Reheat Actual CFM 225 CFM E-AHU-SF-05 I VAV-203 Supply Outlet Summary System l Unit I Outlet Face Area AK Factor Design % Prelim %Final Final Type Reading Prelim Reading Deviatia Reading Outlet-01 TOTAL 230 78 180 98 225 Totals: - [ 230 1 78% 180 98% I 225 * Notes JEDI Balancing, Inc. .. i , 4:5 4 arm tJtJI'USSlG, A BALANCING #3235 #880090250 Air Handling Unit PROJECT:VAIL VALLEY MEDICAL CENTER DATE: 10/2712014 LOCATION:VAIL,CO CONTACT:Trevor Quan PROJECT#: AUTHOR: SYSTEM/UNIT:E-AHU-SF-05 I VAV-204 Tested By: Keenan Dubord AREA: Test Date: October 25, 2014 t Data VAV Address 4 Box Inlet Size 8 K Factor 1.95 Max Design CFM 230 CFM Max Actual CFM 235 CFM Min Design CFM -CFM Reheat Design CFM 230 CFM Reheat Actual CFM 235 CFM E-AHU-SF-05/VAV-204 Supply Outlet Summary System 1 Unit Outlet Face Area AK Factor Design % i Prelim %Final 1 Final Type Reading Prelim Reading Devtatio Reading W Outlet-01 TOTAL 230 102 235 107 235 Totals: I 230 102% 235 102% 235 * Notes JEDI Balancing, Inc. cr 0. 11111 11BAwsTTa Of � . BALANCEVG #3235 #BB009025C Fan Unit PROJECT: VAIL VALLEY MEDICAL CENTER DATE: 10/27/2014 LOCATION:VAIL,CO CONTACT:Trevor Quain PROJECT#: AUTHOR: SYSTEMILINIT:EF-O7 Tested By: Keenan Dubord AREA: Test Date: October 26, 2014 T Unit Data Motor Data Fan Manufacturer GREENI-IFCK Motor Manufacturer VERI-GREEN Fan Model Number SWD-8-V6-5-CW Motor HP 1/2 Fan Serial Number 13864180 Motor RPM 300-2500 Rated CFM 600 Motor Rated Volts 120 Total SP Design 1.5 in.we Motor Phase 1 Total Connected CFM 600 Motor FL Amps 6.9 Motor Service Factor 1.0 Test Data - Total CFM Actual 595 Sheave Data Fan RPM Actual DIRECT DRIVE Motor Sheave Model DIRECT DRIVE Motor Volts 1 Actual 121 Motor Amps 1 Actual 5.8 J E 01 Exhaust Inlet Summary F System f Unit ( Outlet Type of 1 Face Area 1 AK ) Design Prelim �%Prelim Final %Final Type Reading Factor Reading Reading Deviation Reading Deviatio Inlet-01 I CR 80 330 41:3 85 106 - inlet-07 ER 520 700 146 510 98 Totals: • - - - 600 1,490 1132.% 585 99% Notes JEDI Balancing, Inc.