Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B14-0240_A100_1414509600.pdf
4401 F ki.4.4:3"ot e isillitiorios GENERAL DEMOLITION NOTES: 1. DASHED LINES INDICATE ITEMS TO BE REMOVED. DEMOLITION OF WALLS INCLUDES ALL DOORS,WINDOWS AND OTHER ITEMS LOCATED WITHIN THE WALL TO BE REMOVED UNLESS 3 0 NOTED OTHERWISE. RE:STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR EXISTING UTILITIES 2. FADED LINES INDICATE ITEMS TO REMAIN. ivoll 3. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONSTRUCTION RELATED CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITION. 10/28/14 4 II 6 11111 8 2e1978 3e1978 4. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO DEPARTMENTS OR AREAS CL ./-1 THAT ARE IN OPERATION AND SERVED BY SUCH SERVICES.COORDINATE ALL DISRUPTIONS OR M Be1978 ® DISCONTINUATIONS OF UTILITIES AND SERVICES WITH OWNER. iii \._./ 5. ALL FURNISHINGS AND MOVABLE EQUIPMENT IN DEMOLITION/CONSTRUCTION AREA SHALL 11:EERY des i g n ,N 9 BE REMOVED/RELOCATED BY OWNER PRIOR TO START OF DEMOLITION. d- 6. PATCH CORRIDOR WALLS AND RAILINGS TO MATCH EXISTING ADJACENT CONSTRUCTION, PATCH ALL EXISTING WALLS,CEILINGS AND FLOOR TO REMAIN AFTER DEMOLITION IS COMPLETE. N / COORDINATE EXTENT OF SELECTIVE DEMOLITION WITH PROJECT SEQUENCING PLANS AND WITH OTHER TRADES. PATCH WALL BOXES AND OTHER WALUCEILING OPENINGS WHEREVER cy) FIXTURES/OUTLETS ARE BEING REMOVED AND WALLS ARE TO REMAIN. iii O 7. PROVIDE METAL STUD AND GYPSUM BOARD DUST/PRIVACY ENCLOSURES FOR DEMOLITION WORK TO MAINTAIN SEPARATION OF CONSTRUCTION AND IN-USE SPACES. REFER TO SHEET G002 FOR ADDITIONAL INFORMATION. Heery International 8. REVIEW DEMOLITION AND PENETRATIONS THROUGH EXISTING STRUCTURE WITH AS-BUILT 555 17th Street, Suite 500 STRUCTURAL DRAWINGS WHERE POTENTIAL OF ENCOUNTERING LOADED/STRUCTURAL Denver, CO 80202 6 BEAMS/JOISTS/COLUMNS EXIST. 720.946.0276 ' ` ICe1978 — 9. CORE-DRILL EXISTING FLOOR AND/OR ROOF AS REQUIRED FOR NEW PLUMBING OR ELECTRICAL SYSTEMS.SAWCUT FLOOR SLABS TO SLAB DEPTH ONLY,TO PREVENT DAMAGE TO UNDER SLAB UTILITIES. project number — — — — � — — 10. WITH OWNECONTRACTOR TO R PRIOR TORDINATE I.C.R.A.O COMMENCEMENT OF AON CH POHASE/OL SUB-PH SE.SK ESSMENT) PLAN 0 I-- t 13026.01 11. DEMOLITION WORK SHALL NOT REDUCE INTEGRITY OF STRUCTURE TO REMAIN NOR OF FIRE- [ _ PROOFING/SEPARATION. MAINTAIN STRUCTURAL AND LIFE SAFETY INTEGRITY IN AREAS OF LWORK AT ALL TIMES. IA _ If I I --? 12. VERIFY ALL ELECTRICAL AND PLUMBING REQUIREMENTS PRIOR TO REMOVING ANY EQUIPMENT. VAIL VALLEY L — — IDe1978 13. PROVIDE SIGNAGE FOR TEMPORARY CIRCULATION AND EGRESS PATHS DURING DEMOLITION. = — — — — — — — — — — — - — 14. REFER TO MECHANICAL, PLUMBING&ELECTRICAL DRAWINGS FOR OTHER DEMOLITION WORK MEDICAL CENTER O - - I 11 - AND WORK TO REMAIN IN PLACE, REQUIRED FOR EACH CONSTRUCTION SEQUENCE. 2 _ 15. NOTIFY OWNER AND ARCHITECT IMMEDIATELY IF HAZARDOUS MATERIALS ARE ENCOUNTERED.ASBESTOS CATH LA B _' ABATEMENT(OR REMOVAL)TO BE PROVIDED BY OWNER UNDER SEPARATE CONTRACT. COORDINATE WITH GENERAL CONTRACTOR FOR TIMING OF DEMOLITION IN RELATION TO ABATEMENT TO WORK AT EACH CONSTRUCTION SEQUENCE AREA. IGe1978 16. PATCH UNDER SLAB SYSTEMS AND FLOOR SLABS TO MATCH ADJACENT CONSTRUCTION AFTER THE UNDER FLOOR PLUMBING WORK IS COMPLETED AND INSPECTED. REFER TO 0 0 ill _ PLUMBING DOCUMENTS. _. _ _ _ , _ , _ 17. NOTE THAT SOME SYSTEMS WILL REQUIRE WORK BEYOND CONSTRUCTION SEQUENCE ZONES IN ORDER TO _, 181 WEST MEADOW DRIVE , - - - , - ,- - - SUPPORT SPACES WITHIN EACH CONSTRUCTION SEQUENCE.COORDINATE THIS WORK WITH GENERAL VAIL, CO CONTRACTOR AND OWNER PRIOR TO STARTING WORK OUTSIDE OF CONSTRUCTION SEQUENCE AREA. - - - - , - , - ,- COORDINATE DEMOLITION/CONSTRUCTION WORK HOURS,CONSTRUCTION SEQUENCE AND CONSTRUCTION ACCESS WITH OWNER TO MINIMIZE DISRUPTION OF NORMAL DAILY FUNCTION OF OWNER OCCUPIED AREAS. - . , ; ' , . _ _ - _ 11 I 18. NOTIFY OWNER AND ARCHITECT IF UNDER SLAB TEMPORARY DEWATERING IS REQUIRED. owner's project number = 1 19. REVIEW DEMOLITION DOCUMENTS WITH OWNER TO VERIFY ANY ITEMS TO BE SALVAGED AND , _ _ . , - TURNED OVER TO THE OWNER. n _ , ' d 20. NOISE DURING DEMOLITION TO BE KEPT TO A MINIMUM.COORDINATE WITH OWNER 72 HOURS consultants/construction managers III ., — — — ( - — PRIOR TO COMMENCEMENT OF PARTICULARLY NOISY WORK SUCH AS CORE DRILLING. , , , , „ _ , . 21. CONTRACTOR TO PROVIDE M.O.P. (METHOD OF PROCEDURE) PRIOR TO COMMENCEMENT STRUCTURAL: ' - OF WORK IN ANY PHASE/SUB-PHASE WHICH AFFECTS HOSPITAL OPERATION.M.O.P.'S TO STRUCTURAL CONSULTANTS INC. - - • _ - , - - ' = BE APPROVED BY OWNER AT LEAST 72 HOURS PRIOR TO START OF WORK. 3400 EAST BAYAUD AVE., SUITE 300 . ,- _ ' 22. REFER TO SHEET GOO2 FOR SEQUENCING OF WORK, INCLUDING DEMOLITION. DENVER, COLORADO 80209 - _ — 303.399.5154 Je1978 1 — 1 8e2001 — L E G E N D EL 1- 10 MEP: . , _, CATOR RUMA & ASSOCIATES, CO. - '- ; - o_ 896 TABOR STREET - - , , ' LAKEWOOD, CO 80401-4700 DOOR TO BE REMOVED _ . _ _ . , - 303.232.6200 7e2001 � PARTITION TO BE REMOVED INTERIORS: ,J GALLUN-SNOW PARTITION AND BORROWED LIGHT WINDOWS TO BE REMOVED 1920 MARKET STREET, _I===31_ SUITE 201 _1 - - SHOWER OR MOP SINK TO BE REMOVED(PATCH FLOOR AS DENVER, CO 80202 III �_ — 1 X 1 REQUIRED, REFER TO PLUMBING DEMOLITION PLANS) 303.433.9600. , ., „ ,, . , __ . „ , , ,_ _,, . , , , ,, . A , —I� 6e2001 =--_ LAVATORIES AND SINKS TO BE REMOVED(PATCH FLOOR AS seal/signature =_" REQUIRED, REFER TO PLUMBING DEMOLITION PLANS)1= of �,�� fill .0 • 'y'i; EXISTING TOILET TO BE REMOVED(PATCH FLOOR AS REQUIRED, r,, Ofcc:'.41; ,�,II n REFER TO PLUMBING DEMOLITION PLANS) f /2fr; JI E 1 EQUIPMENT TO BE REMOVED/RELOCATED ` IC_g-zj f- �70 L--J UI r I --H I CASEWORK TO BE REMOVED C��S'F(1 p�CE�\���� = 1111 -- - -'�-', LOCKERS TO BE REMOVED (ACTCEILING@8'-O" FIELD VERIFYA = PARTITIONS/ITEMS TO REMAIN issued for date CONSTRUCTION — DOCUMENTS JULY 28, — — — 11E> — — — — — 5e2001 Ill A AREA OF LEVEL ONE CEILING DEMOLITION/DISTURBANCE 2014 41) � item date DEMOLITION KEY NOTES: :: • �♦:♦:♦ 1O REMOVE AND SAVE EXISTING HANDRAIL FOR REINSTALLATION 1 PLAN REVIEW 07.08.2014 '�♦� .... •%•••♦♦ REMOVE EXISTING SYSTEM FURNITURE AND SAVE FOR 2 CONSTRUCTION SET 07.28.2014 �♦� ��♦� _ _ I �♦�♦�♦♦�♦� O REINSTALLATION IN SAME ROOM 3 CCD #02 09.18.2014 ♦♦♦♦♦♦ O REMOVE EXISTING VISION GLASS. ♦ �•� K 7O ACT CEILING @ 8'-0" - �.♦♦♦♦♦ FIELD VERIFY I ♦♦♦♦♦♦♦ . _L 0 EXISTING SYSTEM FURNITURE TO REMAIN. of I.�♦�♦�♦�: O EXISTING FIRE EXTINGUISHER CABINET TO REMAIN. 1 11 r O EXISTING FIRE EXTINGUISHER CABINET TO BE REMOVED. hO. •4*• O REMOVE EXISTING CEILING AS REQUIRED FOR WORK AND REPLACE TO MATCH EXISTING © — — — - - - - _ 1 ADJACENT CEu_ING I IPON COMPLETION OF WORK. �� Y ��� Y �� 8. CUT NEW OPENING IN EXISTING WALL AS REQUIRED FOR MECHANICAL PENETRATIONS. ' O RE: DETAIL 11/A401 PT GYM LI O DEMO ALL CUSTOM CASEWORK. OACT CEILING @,0'-0" O ACT CEILING @ 8'-0" 10. CUT NEW OPENING IN EXISTING WALL AS REQUIRED FOR MECHANICAL PENETRATIONS. FIELD VERIFY FIELD VERIFY — RE: DETAIL 13/A401 •� - - - TREATMENT - _ _ _ r� D n III - - ir ��� - _ _ — 4e2001 1 — II • 4;‘ 4, 4 A 4 i I— . • 1111 4010 �♦�♦�♦�♦�♦�♦�♦�♦ II OFFICE �♦�♦�♦�♦�♦�♦�♦�♦ .• ; — 0 4' 1 U U L / L ED III 1 --,. - _ — — SCALE: 1/8"=1'0 1 .______ O iii - - - - - — — fi D a 0 o 0 a , , , , , a , , a a a a h h n ni I � 1 3e2001 0 GYP SOFFIT AT 8'-8" FIELD VERIFY 2e2001 I— key plan sheet title • i i • 0 — p — — — p ARCHITECTURAL AARCHITECTURAL DEMOLITION PLAN, LEVEL 1e2001 - - DEMOLITION RCP, ONE LEVEL ONE 1n ,/8"=1'-0" IBe200,e200, sheet number A 1 0 0 This document is the property of Heery International,Inc.and Heery International Inc.retains all ,drawn by Author checked by Checker rights therein,including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. identified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc. Ae2001