Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B14-0240_A603_1414509600.pdf
X00 F pA s 4 •41 op* 414‘ ibiltrett 0 id PARTITION TYPE NOTES DEFLECTION TRACK DEFLECTION TRACK DEFLECTION TRACK 1. REFER TO THE ARCHITECTURAL FLOOR PLANS FOR PARTITION �/ TYPE LOCATIONS AND EXTENTS. , �� STRUCTURAL DECK ilaolIPI* STRUCTURAL DECK STRUCTURAL DECK 2. REFER TO SPECIFICATIONS FOR ALTERNATIVE WALLBOARD ,:: _ivSEALANT TYPE TO BE USED IN LIEU OF GYPSUM BOARD AT WET WALLS 10/28/14 SEALANT SEALANT AND ALL WALLS WITH CERAMIC TILE FINISH. o \ \ A CEILING - SEE RCP CEILING - SEE RCP CEILING - SEE RCP 3. PROVIDE BLOCKING AND SUPPORT FOR CASEWORK, EQUIPMENT AO ' N AND ACCESSORIES WHICH REQUIRE INTERNAL REINFORCEMENT I{EEJ3AY desi n -iv 3 1/2" SOUND ATTENUATION BLANKETS ON PARTITION WALLS. REVIEW EQUIPMENT AND ACCESSORIES �_ WHERE NOTED 2 1/2" SOUND ATTENUATION BLANKETS SHOWN ON PLANS AND INTERIOR ELEVATIONS. WHERE NOTED ``I 3 5/8" METAL STUDS @ 16" O.C. 3 1/2" SOUND ATTENUATION BLANKETS WHERE NOTED 4. REFER TO INTERIOR DETAILS FOR PARTITION CONFIGURATIONS AT 6 INTERFACE WITH VARIOUS STRUCTURAL COMPONENTS. 0 10 \ 6" METAL STUDS @ 16" O.C.'1‘ I 2 1/2" METAL STUDS @ 16" O.C. 5/8" GYPSUM WALLBOARD EACH SIDE Heery International 5. GYPSUM BOARD JOINTS ARE TO BE FINISHED DOWN TO FLOOR LEVEL 555 17th Street, Suite 500 AND UP TO SLAB/STRUCTURAL DECK ABOVE. JOINTS ABOVE CEILINGS Denver, CO 80202 5/8" GYPSUM WALLBOARD EACH SIDEII MAY HAVE A REDUCED LEVEL OF FINISH. 720.946.0276 TYPE X FOR FIRE RATED PARTITIONS PI( 5/8" GYPSUM WALLBOARD EACH SIDE TYPE X FOR FIRE RATED PARTITIONS TYPE X FOR FIRE RATED PARTITIONS RUNNER TRACK 6. ALL PARTITIONS SHOWN ARE NON-BEARING. project number RUNNER TRACK FLOORING AND BASE 7. WHEN CONSTRUCTING A RATED WALL, FOLLOW ALL DETAILS OF THE 13026.01 FLOORING AND BASESEE FINISH SCHEDULE LISTED ASSEMBLY. NOT ALL OF THE U.L. REQUIREMENTS ARE 4Ie j ‘ji i LSEE FINISH SCHEDULE iIid11 INDICATED ON THESE DRAWING DETAILS. �� SEALANT SEALANT 8. AT FIRE RATED PARTITIONS USE FIRE RATED SEALANT AT TOP AND VAIL VALLEY RUNNER TRACK III __ � _ �Ilil BOTTOM OF WALL. ACOUSTIC SEALANT SHALL BE USED AT ALL MEDICAL CENTER 1IIlltFLOORING AND BASE NON-FIRE RATED SOUND WALLS. ill I. 2 LAYERS TYPE 'X' 5/8" GYPSUM I 2 LAYERS TYPE 'X' 5/8" GYPSUM SEE FINISH SCHEDULE 9. CONTRACTOR SHALL INCREASE STUD GAUGE AND/OR ADJUST SPACING �� WALLBOARD EACH SIDE OL WALLBOARD EACH SIDE .. OF STUDS IN ORDER TO MEET WALL DEFLECTION CRITERIA, FOR WALL CATH LAB 2 HR CONSTRUCTION 2 HR CONSTRUCTION SEALANT HEIGHTS/ LENGTHS. (U.L. U411) (U.L. U419) TYPE A PARTITION (3 5/8" STUD) TYPE B PARTITION (6" STUD) TYPE C PARTITION (21/2" STUD) 10. REFER TO SPECIFICATIONS FOR ACCEPTABLE MANUFACTURERS AND 1 HOUR CONSTRUCTION = U.L. U419 1 HOUR CONSTRUCTION = U.L. U419 TYPES OF DEFLECTION TRACKS TO BE USED. INSTALL PER UL TESTS WHERE PARTITIONS ARE RATED. 181 WEST MEADOW DRIVE DEFLECTION TRACK DEFLECTION TRACK VAIL, CO �/ DEFLECTION TRACK 11. SEE FLOOR PLAN TAGS AND LIFE SAFETY PLANS FOR LOCATIONS AND STRUCTURAL DECK / i STRUCTURAL DECK � EXTENTS OF FIRE-RATED AND SMOKE-SEALED PARTITIONS. owner's project number ',-. ,„- 7* ! SEALANT 3 5/8" METAL STUD BRACING UP W- N— STRUCTURAL DECK 12. PARTITION TYPE DESIGNATIONS ARE CONTINUOUS ON FLOOR PLANS TO STRUCTURE @ 48" O.C.; UNTIL TAGGED OTHERWISE; CHANGES OCCUR AT PARTITION 1' 4° u.N.o _ INTERSECTIONS AND/OR STRUCTURAL ELEMENTS. consultants/construction managers CEILING - SEE RCP STAGGER BRACING W g Ai iii CEILING - SEE RCP o W- 13. AT ALL DOOR FRAMES, CASED OPENINGS, AND WINDOWS, USE (2) 20 STRUCTURAL: BRACE EACH PAIR OF STUDS u) ---- GA STUDS FULL HEIGHT TO STRUCTURE AT BOTH JAMBS. STRUCTURAL CONSULTANTS INC. �/ W/ RUNNERS @ 24" O.0 = `� 3400 EAST BAYAUD AVE., SUITE 300 VERTICALLY. 3 5/8" METAL STUDS ~ 14. PROVIDE UL APPROVED ASSEMBLIES FOR PENETRATIONS AT DENVER, COLORADO 80209 ~ CEILING - SEE RCP FIRE-RATED PARTITIONS. 303.399.5154 3 1/2" SOUND ATTENUATIONL @ 16" O.C. MEP: BLANKETS WHERE NOTED = cr, 3 1/2" SOUND ATTENUATION 15. PROVIDE SEALANT AND/OR MINERAL WOOL FIRE-SAFEING FOR CATOR RUMA & ASSOCIATES, CO. 3 5/8" METAL STUDS NBLANKETS WHERE NOTED GAPS AT SMOKE-SEALED PARTITIONS. 896 TABOR STREET -...—N @ 16" O.C. 5/8" GYPSUM WALLBOARD EACH SIDE E 3 5/8" METAL STUDS LAKEWOOD, CO 80401-4700 - iri, @ 16" O.C. 16. LABEL ALL FIRE-RATED AND SMOKE-SEALED PARTITIONS ABOVE 303.232.6200 n , FINISHED CEILINGS PER SPECIFICATION REQUIREMENTS. INTERIORS: w V �� 5/8" GYPSUM WALLBOARD GALLUN SNOW / •, _--4, 17. SOUND ATTENUATION BLANKETS SHALL BE COMPATIBLE WITH U.L. 1920 MARKET STREET, w /` AT EXPOSED FACES - - DESIGN NUMBERS. SUITE 201 x DENVER, CO 80202 LT_ 5/8" GYPSUM WALLBOARD , ONE SIDE ONLY 18. ALL NEW PARTITIONS TO BE TYPE A-A(FULL HEIGHT, UNRATED, AND 303.433.9600 W- SOUND INSULATED); U.N.O. seal/signature RUNNER TRACK ♦ RUNNER TRACK 19. ALL GYPSUM BOARD SHALL BE 5/8" THICK; TYPE 'X' AS INDICATED of co,0 RUNNER TRACK 1' IN WALL TAG. • �, R yr FLOORING AND BASE FLOORING AND BASE ,� � '`�. 4 _ii ,,,,:----7-- FLOORING AND BASE SEE FINISH SCHEDULE SEE FINISH SCHEDULE 21• A SEE FINISH SCHEDULE _ / �_g .zo�.f- SEALANT SEALANT SEALANT ,�c TYPE F PARTITION (CHASE WALL) TYPE H PARTITION TYPE J PARTITION issued for date CONSTRUCTION TYPE KEY 2014 STRUCTURAL DECK 1 \ SEE SHEET PARTITION FOR PARTITION TYPE TAGS DOCUMENTS STRUCTURAL DECK item date 28, z PARTITION TYPE I.D. LETTER SAME GA. "CLIP"ANGLE AT 16" O.C. OR - \ AS REQUIRED. SECURE TO COLUMN - NON RATED 1 PLAN REVIEW 07.08.2014 �\ z OR WALL CONDITION BEHIND # HOUR RATING 2 CONSTRUCTION SET 07.28.2014 CEILING - SEE RCP _ - NO SPECIAL FEATURES A SOUND INSULATED FACE OF COLUMN OR WALL CEILING - SEE RCP B LEAD LINED AS SPECIFIED \‘ ‘A\' BEHIND FURRINGC LEAD LINED AND SOUND INSULATED (1/16" LEAD SHIELDING) FACE OF COLUMN OR WALL D SOUND INSULATED WITH VAPOR BARRIER 7/ @ METAL FURRING CHANNELS BEHIND FURRING E THERMALLY INSULATED WITH VAPOR BARRIER G ANCHORED STEEL POSTS WITHIN LOW WALL @ 24" O.C. VERTICAL H STONE VENEER 1 5/8" METAL STUDS @16" O.C. lel J 20 GAUGE STUDS II OR AS REQUIRED AT COLUMN S SPECIAL WALL SYSTEMS; SEE ROOM DETAILS/SECTIONS FURRING LOCATIONS I5/8" GYPSUM WALLBOARD 11 NOTE: REFER TO LIFE SAFETY PLANS FOR INDICATION OF PARTITIONS REQUIRING SMOKE RESISTANCE. 111 5/8" GYPSUM WALLBOARD 1 IFLOORING AND BASE gr FLOORING AND BASE 111J- SEE FINISH SCHEDULE SEE FINISH SCHEDULE s\ SEALANT SEALANT 0 1/2' 1' 1 1/2' TYPE K PARTITION (7/8" FURRING) TYPE Q PARTITION (1 5/8" FURRING) G LE " key plan sheet title STANDARD PARTITION TYPES sheet number A603 . . . This document is the property of Heery International,Inc.and Heery International Inc.retains all drawn by LLI checked by AW rights therein,including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. dentified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc.