Loading...
HomeMy WebLinkAboutB14-0240_E402_1414509600.pdf 0 F kit e isiiillor.0ic Jig 6 • icip„. i fi-r;rin4 ry71/01:0% Voir Igo, l'i 1 LLv GENERAL NOTES: 10/28/14 �I _ iI�af=�u 1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO �w A1 _ _� w REMAIN ARE DENOTED LIGHTLY. 2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE HEE1�Y design OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER i EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. 3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT C b R R I D O R EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. 4. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS HeeryInternational C 2 9 0 B SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 555 17th Street, Suite 500 AC/GFI 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO Denver, CO 80202 ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 720.946.0276 Da,_ �, C e56AC 1AC ®, °ow °� • 6. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH CATH1-5 CATH1-7 CATH1-9 MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH–IN AND © ® i ORDERING MATERIALS OR EQUIPMENT. project number ;in0, P. ,_ ` CATH1-1 CAH1-3 CATH1 PDU EL2 ', n' % / � 0 vI P 7. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION < CORP D 0 R ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, 13026.01 TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH © REFER TO SITE SPECIFIC VENDOf DRAWING 2 0 0 SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, CATH1 UPS FOR ADDITIONAL WORK REQUIREDIN CATH�' ' I I' l Tl OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. � ® LAB AND CONTROL ROOM. COORDINATE WITH 1 C 2 5 A VAIL VALLEY FINAL VENDOR INSTALLATION DRAWINGS PRIOR 8. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER 4 TO INSTALLATION OF EQUIPMENTI ❑ FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CATOR, RUMA & l I I ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE MEDICAL CENTER CATH1-11 EL2D-5,7 ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY I I ® AL WORK SHOWN AS EXISTING ON THESE DRAWINGS. AL V) 9. PROVIDE SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR IN ALL FEEDER, OFFICE ® HOMERUN AND BRANCH CIRCUITS. CATH LAB CAT- LAB OT/PT 200 e Ie 111 TI��-i 250 CATH1-10' Ac 181 WEST MEADOW DRIVE ® POWER PLAN NOTES: '�"' CA 1-8 I AC' VAIL, CO e .17... II 1. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING ELECTRICAL ll NL2 —2,, A /GFI CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL MECHANICAL AND CA '18AOTHER EQUIPMENT INCLUDED IN THIS PROJECT._ , rliit L 111 _ Ac owner's project number Ali,.' ' 2. PROVIDE FUSES SIZED PER EQUIPMENT MANUFACTURER'S REQUIREMENTS.n I—�i CATH1-10 AC��' 029 5B 3. DISCONNECT SWITCH LOCATIONS ARE SHOWN DIAGRAMMATICALLY AND SHALL BE CATH1-8 — p II I1,II� INSTALLED IN ACCESSIBLE LOCATIONS TO SUIT EQUIPMENT AND SPACE. DISCONNECT CATH1-13 II -41, AC1,...6, — SWITCHES SHALL BE WITHIN SIGHT OF THE EQUIPMENT THEY SERVE AND MOUNTED AT consultants/construction managers CATH1-15 9 p CATH1-2 - n �� _ CL2A-35 _ t 6'-3", MAXIMUM, TO TOP OF CABINET. MAINTAIN NEC WORK SPACE REQUIREMENTS. 0 I CAT 1-6 ► °Np CATH1-4 PANEL "CATH1" - STRUCTURAL: 4. RECEPTACLES INDICATED TO BE MOUNTED ABOVE COUNTER ARE TO BE MOUNTED NL2A-22 3 ��` 4n9 CATH1-6 © HORIZONTALLY 6" ABOVE COUNTER. STRUCTURAL CONSULTANTS INC. AC/GFI 3 ?'i SIN< 3400 EAST BAYAUD AVE., SUITE 300 N 2A-99 CL2A 19 5. COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL AND FLOOR DEVICES 41)CL2A-37 �, CATH1-12 WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE OR SPECIALTY EQUIPMENT DENVER, COLORADO 80209 AC \CL2A-35�CL2A-37 "� CATH1-14 SUPPLIER DRAWINGS PRIOR TO ROUGH–IN. 303.399.5154 CL2IA-3 lb ah do 8�� 90 9D AC AC AC AC AC AC n 4 6. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MEP: B _ _ _ _ _ _ _ n iiJ 4 MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH–IN. CATOR RUMA & ASSOCIATES, CO. 90 O 9� 01007. ALL DEVICES FED FROM AN EMERGENCY CIRCUIT SHALL BE RED. 896 TABOR STREET 11 H I I CL2A-3 LAKEWOOD, CO 80401-4700 CL2A-1 CL2A-3 8. PROVIDE HOSPITAL GRADE RECEPTACLES IN PATIENT CARE AREAS AS DEFINED IN NEC 517.2, INCLUDING ALL PATIENT EXAM, SLEEPING, PROCEDURE, DIAGNOSTIC AND 303.232.6200 TREATMENT ROOMS. INTERIORS: 41) CO\ TROL 9. NO RECEPTACLES SHALL BE MOUNTED BELOW +24" AFF. GALLUN-SNOW CL2A-5 10. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V AND 277V CIRCUIT. 1920 MARKET STREET, 2 0 0 C CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING SUITE 201 n CL2A– CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. WHERE CIRCUITS DENVER CO 80202 ARE COMBINED WITHIN A SINGLE CONDUIT, PROVIDE STRIPING FOR FULL LENGTH OF ' NEUTRAL CONDUCTOR INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED 303.433.9600 PHASE CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES. I CL2A-19 NL2A-22 CL2A-5 CL2A-19 seal/signature 911 ® 010 916 :,;.(11',,.,; .- - ALL KEY NOTES 4 41821 ,� ., it T-v STORAC- `. @r I 4,ff O PROVIDE A RECEPTACLE DROPCORD REEL, MEDREEL #MR-20-13-14–D–M OR 't r ' C 2 9 5 C APPROVED EQUAL. °u ',-: °'G.." 2 7 L As. PROVIDE THREE DOUBLE–DUPLEX RECEPTACLES MOUNTED IN A PEDESTAL ON THE �, ""' FLOOR. ROUTE POWER BELOW FLOOR AND UP INTO PEDESTAL. © PROVIDE A 480V SHUNT–TRIP CIRCUIT BREAKER WITH 120V COIL FOR CATH LAB issued for date EQUIPMENT IN FLUSH MOUNTED NEMA 1 ENCLOSURE. REFER TO ONE–LINE DIAGRAM FOR MORE INFORMATION. CONSTRUCTION 4 SECOND FLOOR ENLARGED POWER PLAN 0 120V EMERGENCY POWER OFF (EPO) BUTTON FOR CONTROL OF THE SHUNT–TRIP DOCUMENTS JULY 28, CIRCUIT BREAKERS. MOUNT AT +60" AFF. COORDINATE EXACT LOCATION WITH 2014 SCALE: 1/4"=1'-0" VENDOR DRAWINGS. © PROVIDE A LINE–ISOLATION PANEL, PG LIFELINK 10KVA, 480V-120V, 16 CIRCUIT, WITH A LINE ISOLATION MONITOR ON THE FRONT. item date 1 PLAN REVIEW 07.08.2014 2 CONSTRUCTION SET 07.28.2014 3 CCD-2 09.18.2014 N 0 4' 8' 16' lil ET) SCALE:1/8"= 1'-0" key plan sheet title SECOND FLOOR ENLARGED POWER PLAN sheet number E 4 0 2 J This document is the property of Heery International,Inc.and Heery International Inc.retains all drawn by JDD I checked by WAT Caton, Ruma & Assoc. FILENAME:P: VVMC 2014-130 CATH LAB REMODEL CAD ELEC P–QPWR2.DWG _ E402 PLOT: 09/18/2014 @ 9:35am REV: 07/28/2014 CAD: NWondel XREF: b 2.dw xb 2–SECONDFLOORFLOORPLAN.dw xb 2–SECONDFLOORDEMOLITIONPLAN.dw xb 2–EXISTINGROOMNAMESFORSHEETAF-100.dw xb 2–EXISTINGROOMNAMESFORSHEETAD100.dw tb.dw wr2.dw rights therein,including copyrights. It may only be used in a manner consistent with Heery 9 9 9 9 9 9 9 9 9 9 9 qp 9 International Inc.'s rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. identified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc.