Loading...
HomeMy WebLinkAboutB14-0240_E701_1414509600.pdf 411.1 F s 44 .44 iillot 12 Li 1 ict ill oil CI. 4V NEW PANEL "CL2A" NEW PANEL "CL2C" *el it° Panel Notes: Panel Nates: M.L.O. VOLTAGE 120 / 208 V 1.CONNECT LOAD FROM ASSOCIATED PANEL"CL2A"REMOVED DURING DEMOLITION. M.L.O. VOLTAGE 120 / 208 V 1.CONNECT LOAD FROM ASSOCIATED PANEL"EL2C"REMOVED DURING DEMOLITION. 100A BUS PHASE 3 PH 100A BUS PHASE 3 PH WIRE 4 W WIRE 4 W MFR: MFR: 10/28/14 MTG.: SURFACE 10,000 AMPERE SHORT CIRCUIT RATING(FULLY RATED) MTG.: SURFACE 10,000 AMPERE SHORT CIRCUIT RATING(FULLY RATED) BREAKER BREAKER BREAKER BREAKER NOTE DESCRIPTR-CATH CTRL ION LTG RECEPTMOTORSMOTORS OTHER GENERAL TOTAL540 AMP � 1 P CCT PAH CCT AMP � 1 P TOTAL 0 GENERAL OTHER MOTORS RECEPT LTG DESCRIPTSPARE NURSE LNG NOTE NOTE DESCRIPTIR-EM HDWL2120N--213 LTG RECEPT MOTORS OTHER GENERAL TOTAL 0 AMP � 1 P CCT PAH CCT AMP � 1 P TOTAL 0 GENERAL OTHER MOTORS RECEPT LTG DESCRIPTIR-EM HDWL201-202 NOTE HEERY design R-CATH CTRL 360 50 410 20 / 1 3 B 4 20 / 1 1080 1,080 R-PENTHOUSE 1 1 R-EM HDWL 209-211 0 20 / 1 3 B 4 20 / 1 0 R-EM HDWL 203-205 1 R-CATH CTRL 540 540 20 / 1 5 C 6 20 / 1 0 SPARE 3RD FL ELEV. 1 1 FCU WEST 211-213/L-CMM LOBBY 0 20 / 1 5 C 6 20 / 1 0 R-EM HDWL 206-208 1 1 R-PCU W NURSE ST 540 540 20 / 1 7 A 8 20 / 1 1000 1,000 R-LENNEL IT CLOSET 1 1 FCU'S SOUTH 201-208 0 20 / 1 7 A 8 20 / 1 0 R-EM HDWL 200D 1 1 R-PCU W NURSE ST 540 540 20 / 1 9 B 10 20 / 1 1000 1,000 R-IT CABINET IN IT RM 1 1 FCU,S DR.ON CALL 0 20 / 1 9 B 10 20 / 1 0 R-EM HDWL 200C 1 SPARE PCU WEST 0 20 / 1 11 C 12 20 / 1 1000 1,000 R-CELL BOOST/INT 1 1 R-EM HDWL 214 0 20 / 1 11 C 12 20 / 1 0 NURSE CONSOLE HP 1 1 R-PT CLOSET/LENEL 1,080 1080 20 / 1 13 A 14 20 / 1 720 720 R-PED/CATH/EXAM HW 1 R-EM HDWL 216-217 0 20 / 1 13 A 14 20 / 1 0 SPARE 1 R-PCU N NURSE ST 540 540 20 / 1 15 B 16 20 / 1 720 720 R-PED/CATH/EXAM HW 1 R-EM HDWL 219,218 0 20 / 1 15 B 16 20 / 1 0 R-EM HDWL 200A SOUTH 1 1 R-PCU N NURSE ST 540 540 20 / 1 17 C 18 20 / 1 180 180 R-PED/CATH/EXAM 1 R-COR CART PCU N. 0 20 / 1 17 C 18 20 / 1 0 R-EM HDWL 200A NORTH 1 R-CATH CTRL 360 100 460 20 / 1 19 A 20 20 / 1 360 360 R-CRASH CART 1 PYXIS 0 20 / 1 19 A 20 20 / 1 0 2ND FLOOR EXAM 1 Heery International SPAREI0 20 / 1 21 B 22 20 / 1 1000 1,000 R-NOURISH REF 1 R-EM HDWL 220 0 20 / 1 21 B 22 20 / 1 0 PCU REF PYXIS MED RMS 1 555 17th Street, Suite 500 R-PATIENT RM 3 720 720 20 / 1 23 C 24 20 / 1 1500 1,500 R-NOURISH COFFEE 1 PYXIS-NURSE STATION 0 20 / 1 23 C 24 20 / 1 0 SPARE R-PATIENT RM 4 720 720 20 / 1 25 A 26 20 / 1 1000 1,000 R-NOURISH ICE SPARE 0 20 / 1 25 A 26 20 / 1 0 SPARE Denver, CO 80202 R-PATIENT RM 3&4 360 360 20 / 1 27 B 28 20 / 1 1500 1,500 R-NOURISH MICRO SPARE 0 20 / 1 27 B 28 20 / 1 0 SPARE 720.946.0276 R-PATIENT RM 10 720 720 20 / 1 29 C 30 20 / 1 0 SPARE SPARE 0 20 / 1 29 C 30 20 / 1 0 SPARE R-PATIENT RM 11 720 720 20 / 1 31 A 32 20 / 1 0 SPARE SPARE 0 20 / 1 31 A 32 20 / 1 0 SPARE R-PATIENT RM 10&11 720 720 20 / 1 33 B 34 20 / 1 0 SPARE SPARE 0 20 / 1 33 B 34 20 / 1 0 SPARE R-CATH WEST 0 20 / 1 35 C 36 20 / 1 0 SPARE SPARE 0 20 / 1 35 C 36 20 / 1 0 SPARE project number R-CATH WEST 0 20 / 1 37 A 38 20 / 1 0 SPARE SPARE 0 20 / 1 37 A 38 20 / 1 0 SPARE 13026.01 SPARE 0 20 / 1 39 B 40 20 / 1 0 SPARE SPARE 0 20 / 1 39 B 40 20 / 1 0 SPARE SPARE 0 20 / 1 41 C 42 20 / 1 0 SPARE SPARE 0 20 / 1 41 C 42 20 / 1 0 SPARE PHASE LOADING SUMMARY PANEL LOADING SUMMARY GENERAL NOTES: BREAKER ACCESSORIES LOAD TYPE(VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND 'PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. *=GFCI LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED.INDICATE NEW SPARES IN PENCIL. **=SHUNT TRIP VA IL VALLEY RECEPTACLES 5,040.0 4,320.0 2,700.0 CONNECTED PF= MOTORS 0.0 0.0 0.0 LIGHTING 0.0 KVA x 125%= 0.0 KVA x 95% = 0.0 KW 100% MEDICAL CENTER OTHER 0.0 0.0 0.0 RECEPTACLES GENERAL 2,100.0 3,550.0 2,500.0 FIRST 10 KVA 10.0 KVA x 100%= 10.0 KVA x 100% = 10.0 KW CONNECTED TOTAL(VA) 7,140.0 7,870.0 5,200.0 REMAINDER 2.1 KVA x 50%= 1.0 KVA x 100% = 1.0 KW AMPACITY = MOTORS 56.1 CATH L A B NEC CALCULATED LARGEST 0.0 KVA x 125%= 0.0 KVA x 90% = 0.0 KW PHASE AMPACITY 59.4 65.5 43.3 REMAINDER 0.0 KVA x 100%= 0.0 KVA x 90% = 0.0 KW NEC DEMAND OTHER 0.0 KVA x 125%= 0.0 KVA x 100% = 0.0 KW AMPACITY = #VALUE! GENERAL 8.2 KVA x 100%= 8.2 KVA x 100% = 8.2 KW 53.2 PHASE BALANCE A-B B-C C-A 10% 51% 37% TOTAL 20.2 KVA 19.2 KVA 19.2 KW GENERAL NOTES: BREAKER ACCESSORIES 181 WEST MEADOW DRIVE 'PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. *=GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED.INDICATE NEW SPARES IN PENCIL. **=SHUNT TRIP VAI L, CO owner's project number NEW PANEL "NL2A" NEW PANEL "CH2A" Panel Notes: Panel Notes: M.L.O. VOLTAGE 120 / 208 V 1.CONNECT LOAD FROM ASSOCIATED PANEL"L2A"REMOVED DURING DEMOLITION. M.L.O. VOLTAGE 277 / 480 V 1.CONNECT LOAD FROM ASSOCIATED PANEL"CL2A"REMOVED DURING DEMOLITION. consultants/construction managers 100A BUS PHASE 3 PH 250A BUS PHASE 3 PH WIRE 4 W WIRE 4 W MFR: MFR: STRUCTURAL: MTG.: SURFACE 10,000 AMPERE SHORT CIRCUIT RATING(FULLY RATED) MTG.: SURFACE ©25,000 'MPERE SHORT CIRCUIT RATING(FULLY RATED) STRUCTURAL CONSULTANTS INC. BREAKER BREAKER BREAKER BREAKER 3400 EAST BAYAUD AVE., SUITE 300 NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE DENVER, COLORADO 80209 1 R-NURSE DIR.OFFICE 1,080 1080 20 / 1 1 A 2 20 / 1 500 500 R-NOISE GEN PCU W 1 ISO PANEL CATH1 0 2,880 0 0 0 0 30 / 2 1 A 2 20 / 1 0 LIGHTING 303.399.5154 R-MECH 1,080 1080 20 / 1 3 B 4 20 / 1 360 360 R-LINEN/JANITOR 1 0 2,880 0 0 0 0 3 B 4 20 / 1 0 1 R-MED.CONFERENCE 540 540 20 / 1 5 C 6 20 / 1 500 500 DRINKING FOUNTAIN 1 0 20 / 1 5 C 6 20 / 1 o MEP: 1 R-NURSE DIR.OFFICE 1,080 1080 20 / 1 7 A 8 20 / 1 1176 1,176 EX.FAN#1 1 0 20 / 1 7 A 8 20 / 1 0 CA-10R RUMA & ASSOCIATES, CO. 1 R-DR.O.C.LOBBY 1,080 1080 20 / 1 9 B 10 20 / 1 1176 1,176 N.E.EX.FAN 1 0 20 / 1 9 B 10 20 / 1 0 896 TABOR STREET 4 8 R-CATH HALLS,LKR 1,260 1260 20 / 1 11 C 12 20 / 1 400 400 R-200 A-B/LIGHTING 1 0 20 / 1 11 C 12 20 / 1 o LAKEWOOD, CO 80401-4700 1 R-SOIL/MED.WK.DICT 1,080 1080 I 20 / 1 13 A 14 20 / 1 1440 1,440 R-HEADWAII 200 A-D 1 0 20 / 1 13 A 14 20 / 1 0 R-PED/CATH EXAM 360 360 20 / 1 15 B 16 20 / 1 1440 1,440 R-200 C-D 1 0 20 / 1 15 B 16 20 / 1 0 303.232.6200 R-CATH STORAGE 1,080 1080 20 / 1 17 C 18 20 / 1 1440 1,440 R-PED/CATH EXAM HW 0 20 / 1 17 C 18 20 / 1 o INTERIORS 1 L-BATH 200 A-D/HEAD LTD 400 400 20 / 1 19 A 20 20 / 1 560 540 20 R-SOIL,LINEN,NOUR 0 20 / 1 19 A 20 20 / 1 0 1 R-1ST FL.ROOF 360 360 20 / 1 21 B 22 20 / 1 900 900 CATH LAB,CTRL 0 20 / 1 21 B 22 20 / 1 o GALL U N-S N O W R-HALLS,HSK,TUB 10 720 730 20 / 1 23 C 24 20 / 1 900 900 MED SUPPLIES 1 0 20 / 1 23 C 24 20 / 1 0 1920 MARKET STREET, 1 R-2ND FL.ELEV.LBY 360 360 20 / 1 25 A 26 20 / 1 560 540 20 CATH LAB 0 20 / 1 25 A 26 20 / 1 0 SUITE 201 1 CATV 1,000 1000 20 / 1 27 B 28 20 / 1 0 SPARE 0 20 / 1 27 B 28 20 / 1 0 1 R-2ND FL.ELEV.LBY 360 360 20 / 1 29 C 30 20 / 1 1080 1,080 R-OFFICE 240 1 0 20 / 1 29 C 30 20 / 1 0 DENVER, CO 80202 R-PTRM 3&4 HEADWALL 1,440 1440 20 / 1 31 A 32 20 / 1 0 SPARE 0 I 20 / 1 31 A 32 20 / 1 0 303.433.9600 R-PATIENT RM 3&4 720 720 20 / 1 33 B 34 20 / 1 0 SPARE 0 20 / 1 33 B 34 20 / 1 0 R-PTRM 10&11 HEADWALL 1,440 1440 20 / 1 35 C 36 20 / 1 0 SPARE 0 20 / 1 35 C 36 20 / 1 0 R-PATIENTRM 10&11 1,440 1440 20 / 1 37 A 38 20 / 1 0 SPARE CATH1 UPS 13,296 13296 60 / 3 37 A 38 125 / 3 27700 27,700 CATH1 PDU seal/signature OFFICE OT/PT 900 900 20 / 1 39 B 40 20 / 1 0 SPARE - 13,296 13296 39 B 40 27700 27,700 - ,s+•'efas,y R-TEMP STORAGE 1,080 1080 20 / 1 41 C 42 20 / 1 0 SPARE - 13,296 13296 41 C 42 27700 27,700 R;• � ,��.�7 PHASE LOADING SUMMARY PANEL LOADING SUMMARY PHASE LOADING SUMMARY PANEL LOADING SUMMARY .•� '� f >i, LOAD TYPE(VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND LOAD TYPE(VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND �` ''r LIGHTING 440.0 0.0 410.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL +' -+ � 21 � RECEPTACLES 9,000.0 7,200.0 9,900.0 95% CONNECTED PF= RECEPTACLES 2,880.0 2,880.0 0.0 95% CONNECTED PF= `,. `.:tij j ) ��. , MOTORS 1,176.0 1,176.0 500.0 LIGHTING 0.9 KVA x 125%= 1.1 KVA x = 1.0 KW 99% MOTORS 0.0 0.0 0.0 LIGHTING 0.0 KVA x 125%= 0.0 KVA x = 0.0 KW 100% /f` J OTHER 0.0 0.0 0.0 RECEPTACLES OTHER 0.0 0.0 0.0 RECEPTACLES , ie./ft'' GENERAL 500.0 1,000.0 0.0 FIRST 10 KVA 10.0 KVA x 100%= 10.0 KVA x 100% = 10.0 Kw CONNECTED GENERAL 40,996.0 40,996.0 40,996.0 FIRST 10 KVA 5.8 KVA x 100%= 5.8 KVA x 100% = 5.8 KW CONNECTED %f" ''.40',d` 'o AL'7; , TOTAL(VA) 11,116.0 9,376.0 10,810.0 REMAINDER 16.1 KVA x 50%= 8.1 KVA x 100% = 8.1 KW AMPACITY = TOTAL(VA) 43,876.0 43,876.0 40,996.0 REMAINDER 0.0 KVA x 50%= 0.0 KVA x 100% = 0.0 KW AMPACITY = *.......... * MOTORS 86.9 MOTORS 154.9 NEC CALCULATED LARGEST 0.0 KVA x 125%= 0.0 KVA x 90% = 0.0 KW NEC CALCULATED LARGEST 0.0 KVA x 125%= 0.0 KVA x 90% = 0.0 KW PHASE AMPACITY 95.8 80.4 91.8 REMAINDER 2.9 KVA x 100%= 2.9 KVA x 90% = 2.6 KW NEC DEMAND PHASE AMPACITY 158.1 158.1 147.8 REMAINDER 0.0 KVA x 100%= 0.0 KVA x 90% = 0.0 KW NEC DEMAND issued for date OTHER 0.0 KVA x 125%= 0.0 KVA x 100% = 0.0 KW AMPACITY = OTHER 0.0 KVA x 125%= 0.0 KVA x 100% = 0.0 KW AMPACITY = #VALUE! GENERAL 1.5 KVA x 100%= 1.5 KVA x 100% = 1.5 KW 65.1 #VALUE! GENERAL 123.0 KVA x 100%= 123.0 KVA x 100% = 123.0 KW 154.9 CON S T R U C T I O N PHASE BALANCE A-B B-C C-A PHASE BALANCE A-B B-C C-A JULY 28 I 19% 15% 3% TOTAL 31.3 KVA 23.5 KVA 23.1 KW 0% 7% 7% TOTAL 128.7 KVA 128.7 KVA 128.7 KW DOCUMENTS 2014 GENERAL NOTES: BREAKER ACCESSORIES GENERAL NOTES: BREAKER ACCESSORIES 'PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. *=GFCI 'PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. *=GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED.INDICATE NEW SPARES IN PENCIL. **=SHUNT TRIP ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED.INDICATE NEW SPARES IN PENCIL. **=SHUNT TRIP item date NEW PANEL *CATH1„ 1 PLAN REVIEW 07.08.2014 Panel Notes: 2 CONSTRUCTION SET 07.28.2014 30 A MAIN CIRCUIT BREAKER VOLTAGE 120 1.THIS ISA 10KVA ISOLATION PANEL(480V PRI-120V SEC). 3 CCD-2 09.18.2014 PHASE 1 PH WIRE 2 W TYPE: MTG.: FLUSH 10,000 AMPERE SHORT CIRCUIT RATING(FULLY RATED) BREAKER BREAKER NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE CEILING CORDREEL 180 180 20 / 2 1 A 2 20 / 2 360 360 PEDESTAL CEILING CORDREEL 180 180 20 / 2 3 A 4 20 / 2 360 360 PEDESTAL NORTH WALL 720 720 20 / 2 5 A 6 20 / 2 360 360 PEDESTAL NORTH WALL 360 360 20 / 2 7 A 8 20 / 2 540 540 EAST WALL NORTH WALL 360 360 20 / 2 9 A 10 20 / 2 540 540 EAST WALL ST WALL 360 360 20 / 2 11 A 12 20 / 2 360 360 SOUTH WALL A BOOM 720 720 20 / 2 13 A 14 20 / 2 _6i .0 L BOOM 720 720 20 / 2 15 B 16 20 / 2 720 720 BOOM PHASE LOADING SUMMAR PANEL LOADING SUMMARY LOAD TYPE(VA) PH A LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL CONNECTED PF= 100% LIGHTING 0.0 LIGHTING 0.0 KVA x 125%= 0.0 KVA x 95% = 0.0 KW RECEPTACLES 5760.0 RECEPTACLES CONNECTED MOTORS 0.0 FIRST 10 KVA 5.8 KVA x 100%= 5.8 KVA x 100% = 5.8 KW AMPACITY = OTHER 0.0 REMAINDER 0.0 KVA x 50%= 0.0 KVA x 100% = 0.0 KW 48.0 GENERAL 0.0 MOTORS TOTAL 5760.0 LARGEST 0.0 KVA x 125%= 0.0 KVA x 90% = 0.0 KW NEC DEMAND REMAINDER 0.0 KVA x 100%= 0.0 KVA x 90% = 0.0 KW AMPACITY = OTHER 0.0 KVA x 125%= 0.0 KVA x 100% = 0.0 KW 48.0 GENERAL 0.0 KVA x 100%= 0.0 KVA x 100% = 0.0 KW TOTAL 5.8 KVA 5.8 KVA 5.8 KW GENERAL NOTES: BREAKER ACCESSORIES 'PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. *=GFCI N ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED.INDICATE NEW SPARES IN PENCIL. **=SHUNT TRIP 0 4' 8' 16' IEB SCALE:1/8"= 1'-0" key plan sheet title ELECTRICAL SCHEDULES sheet number E 7 0 1 J This document is the property of Heery International,Inc.and Heery International Inc.retains all drawn by NCW I checked by NCW Cator, Ruma & Assoc. FILENAME:P:\VVMC\2014-130 CATH LAB REMODEL\CAD\ELEC\P-ES.DWG - E701 PLOT: 09/18/2014 © 9:36am REV: 09/17/2014 CAD: NWondel XREF: tb.dwg rights therein,including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. identified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc.