Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B14-0240_E702_1414509600.pdf
oti F 41,4 s ca ri id • ' cc rig3 2ND FLOOR NORMAL LIGHTING CIRCUIT LOAD SUMMARY NEW PANEL "EH2F" Panel Notes: 0,4) 0114i PANEL H2A M.L.O. VOLTAGE 277 / 480 V lain 1 150A BUS PHASE 3 PH LOAD ADDED QTY VA WIRE 4 W D1 8 168 MFR: 10/28/14 W1 3 48 MTG.: SURFACE A 25,000 AMPERE SHORT CIRCUIT RATING(FULLY RATED) W2 4 128 W3 8 96 IBREAKER BREAKER EXISTING LED 2X4 25 1250 NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE EXISTING LED 2X2 1 40 HUMIDIFIER(H-1) 10,000 10,000 45 / 3 1 A 2 15 / 3 903 903 AIR HANDLING UNIT HEERY design EXISTING 2X4 BASKET 9 576 3 51 2 60 10,000 10,001 3 B 4 903 903 (AHU-1) S2 2 60 10,000 10,000 5 C 6 903 903 S3 1 26 HUMIDIFIER(H-2) 2,667 2,667 20 / 3 7 A 8 45 / 3 6371 6,371 CONDENSING UNIT LOAD REMOVED 2,667 2,667 9 B 10 6371 6,371 (ACCU-3) EXISTING LED 2X4 25 1250 2,667 2,667 11 C 12 6371 6,371 EXISTING LED 2X2 2 90 HUMIDIFIER(H-3) 4,000 4,000 20 / 3 13 A 14 20 / 1 0 SPARE EXISTING 2X4 BASKET 9 576 4,000 4,000 15 B 16 20 / 1 0 SPARE 2X4 6 384 4,000 4,000 17 C 18 20 / 1 0 SPARE DOWNLIGHT 9 468 HUMIDIFIER(H-4) 3,333 3,333 20 / 3 19 A 20 20 / 1 0 SPARE Heery International SURFACE 5 320 3,333 3,333 21 B 22 20 / 1 0 SPARE 555 17th Street, Suite 500 NET LOAD REMOVED 636 VA 3,333 3,333 23 C 24 20 / 1 0 SPARE EXHAUST FAN(EF-2) 425 425 15 / 3 25 A 26 20 / 3 3183 500 0 2,683 0 0 PANEL"EL2D" Denver, CO 80202 425 425 27 B 28 2995 500 0 2,495 0 0 VIA TRANSFORMER 720.946.0276 425 425 29 C 30 1820 0 0 1,820 0 0 2ND FLOOR EGRESS LIGHTING CIRCUIT SPARE 0 20 / 1 31A 32 20 / 1 0 SPARE SPARE 0 20 / 1 33 B 34 20 11 0 SPARE SPARE 0 20 / 1 35 C 36 20 / 1 0 SPARE project number PANEL EH1L I SPARE 0 20 / 1 37 A 38 20 / 1 0 SPARE SPARE 0 20 / 1 39 B 40 20 / 1 0 SPARE 13026.01 LOAD ADDED QTY VA SPARE 0 20 / 1 41 C 42 20 / 1 0 SPARE EXISTING LED 2X4 2 100 PHASE LOADING SUMMARY PANEL LOADING SUMMARY EXISTING 2X4 BASKET 3 192 LOAD TYPE(VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND VA I L VALLEY LOAD REMOVED LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL EXISTING 2X4 BASKET 1 64 RECEPTACLES 0.0 0.0 0.0 CONNECTED PF= 2X4 3 288 MOTORS 9,957.0 9,769.0 9,094.0 LIGHTING 0.0 KVA x 125%= 0.0 KVA x 95% = 0.0 KW 97% MEDICAL CENTER NET LOAD REMOVED 60 VA OTHER 20,424.9 20,424.9 20,424.9 RECEPTACLES GENERAL 500.0 500.0 0.0 FIRST 10 KVA 0.0 KVA x 100%= 0.0 KVA x 100% = 0.0 KW CONNECTED TOTAL(VA) 30,881.9 30,693.9 29,518.9 REMAINDER 0.0 KVA x 50%= 0.0 KVA x 100% = 0.0 KW AMPACITY = MOTORS 109.6CATH LAB "MDC"LOAD SUMMARY NEC CALCULATED LARGEST 2.7 KVA x 125%= 3.4 KVA x 90% = 3.0 KW PHASE AMPACITY 135.4 134.8 130.5 REMAINDER 26.1 KVA x 100%= 26.1 KVA x 90% = 23.5 KW NEC DEMAND OTHER 61.3 KVA x 125%= 76.6 KVA x 100% = 76.6 KW AMPACITY = CAPACITY 2494 KVA #VALUE! GENERAL 1.0 KVA x 100%= 1.0 KVA x 100% = 1.0 KW 128.8 (3000A MDC) PHASE BALANCE A-B B-C C-A EXISTING PEAK DEMAND 1086 KVA 1% 4% 5% TOTAL 91.1 KVA 107.1 KVA 104.1 KW (1306A) GENERAL NOTES: BREAKER ACCESSORIES NEC DEMAND FACTOR x 125% ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED.INDICATE NEW SPARES IN PENCIL. *=GFCI 181 WEST MEADOW DRIVE NEC CORRECTED PEAK DEMAND LOAD 1358 KVA =SHUNT TRIP VAI L, CO LOAD ADDED - PANEL"CH2A" 129 KVA LOAD REMOVED NORMAL LIGHTING 1 KVA NEW TOTAL LOAD 1486 KVA NEW PANEL "EL2D" owner's project number Panel Notes: 100A MAIN CIRCUIT BREAKER VOLTAGE 120 / 208 V 100A BUS PHASE 3 PH consultants/construction managers "EHDP"LOAD SUMMARY WIRE 4 W MFR: STRUCTURAL: CAPACITY 374 KVA MTG.: SURFACE 10,000 AMPERE SHORT CIRCUIT RATING(FULLY RATED) STRUCTURAL CONSULTANTS INC. (450A) EXISTING PEAK DEMAND 152 KVA BREAKER BREAKER 3400 EAST BAYAUD AVE., SUITE 300 (183 A) NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE DENVER, COLORADO 80209 NEC DEMAND FACTOR x 125% AC SPLIT SYSTEM 1,319 1319 20 / 2 1 A 2 20 / 1 -us -01 = T - 303.399.5154 NEC CORRECTED PEAK DEMAND LOAD 190 KVA (AC-1/ACCU-1) 1,319 1319 3 B 4 20 / 1 500 500 MECH CTRLS LOAD ADDED AC SPLIT SYSTEM 1,364 1364 30 / 2 5 C 6 20 / 1 456 456 UH-1 3 MEP: PANEL"EH2F" 104 KVA (AC-2/ACCU-2) 1,364 1364 7 A 8 20 11 r •A' EXHAUST FAN(EF-1) 1,176 1176 20 / 1 9 B 10 20 / 1 0 SPARE CATOR RUMA & ASSOCIATES, CO. NEW TOTAL LOAD 294 KVA 896 TABOR STREET SPARE 0 20 / 1 11 C 12 20 / 1 0 SPARE SPARE 0 20 / 1 13 A 14 20 / 1 0 SPARE LAKEWOOD, CO 80401-4700 SPARE 0 20 / 1 15 B 16 20 / 1 0 SPARE 303.232.6200 "EDPB"LOAD SUMMARY SPARE 0 20 / 1 17 C 18 20 / 1 0 SPARE SPARE 0 20 / 1 19 A 20 20 / 1 0 SPARE INTERIORS: SPARE 0 20 / 1 21 B 22 20 / 1 0 SPARE GALLUN-SNOW CAPACITY 997 KVA SPARE 0 20 / 1 23 C 24 20 / 1 0 SPARE 1920 MARKET STREET, (1200A) SPARE 0 20 / 1 25 A 26 20 / 1 0 SPARE EXISTING PEAK DEMAND 347 KVA SPARE 0 20 / 1 27 B 28 20 / 1 0 SPARE SUITE 201 (417 A) SPARE 0 20 / 1 29 C 30 20 / 1 0 SPARE DENVER, CO 80202 NEC DEMAND FACTOR x 125% PHASE LOADING SUMMARY PANEL LOADING SUMMARY NEC CORRECTED PEAK DEMAND LOAD 434 KVA 303.433.9600 LOAD ADDED LOAD TYPE(VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND PANEL"CH2A" 129 KVA LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL - PANEL"EH2F" 104 KVA RECEPTACLES 0.0 0.0 0.0 CONNECTED PF= seal/signature MOTORS 2,683.0 2,495.0 1,820.0 LIGHTING 0.0 KVA x 125%= 0.0 KVA x 95% = 0.0 KW 91% tyi.r.ivsg.. NEW TOTAL LOAD 667 KVA OTHER 0.0 0.0 0.0 RECEPTACLES ■_�y.1� f e"r„ GENERAL 500.0 500.0 0.0 FIRST 10 KVA 0.0 KVA x 100%= 0.0 KVA x 100% = 0.0 KW CONNECTED �� Y ` a�'(�'• �p TOTAL(VA) 3,183.0 2,995.0 1,820.0 REMAINDER 0.0 KVA x 50%= 0.0 KVA x 100% = 0.0 KW AMPACITY = !� ?.`, Q•` y` MOTORS 22.2 •V ��"STT 4�S2f -,• c: "DPA"LOAD SUMMARY NEC CALCULATED LARGEST 2.7 KVA x 125%= 3.3 KVA x 90% = 3.0 KW •`! rt s PHASE AMPACITY 29.3 27.7 18.0 REMAINDER 4.3 KVA x 100%= 4.3 KVA x 90% = 3.9 KW NEC DEMAND 7�6F "/ .'''` OTHER 0.0 KVA x 125%= 0.0 KVA x 100% = 0.0 KW AMPACITY = °•. (,/+* LOAD ADDED `' ** ** .'` 100.0 GENERAL 1.0 KVA x 100%= 1.0 KVA x 100% = 1.0 KW 24.0 �i'j� Chi PANEL"NL2A" 23 KVA A),E PHASE BALANCE A-B B-C C-A LOAD REMOVED 6% 65% 75% TOTAL 8.0 KVA 8.7 KVA 7.9 KW RECEPTACLES(QTY 142) 26 KVA GENERAL NOTES: BREAKER ACCESSORIES ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED.INDICATE NEW SPARES IN PENCIL. *=GFCI issued for date NET LOAD REMOVED 3 KVA **=SHUNT TRIP _ CONSTRUCTION DOCUMENTS JULY 28, "CDLBA"LOAD SUMMARY 2014 CAPACITY 75 KVA (400A) item date EXISTING PEAK DEMAND 33 KVA (40 A) NEC DEMAND FACTOR x 125% 1 PLAN REVIEW 07.08.2014 NEC CORRECTED PEAK DEMAND LOAD 41 KVA LOAD ADDED 2 CONSTRUCTION SET 07.28.2014 PANEL"CL2A" 19 KVA 3 CCD-2 09.18.2014 LOAD REMOVED RECEPTACLES(QTY 43) 8 KVA NEW TOTAL LOAD 53 KVA "CDHBA"LOAD SUMMARY CAPACITY 208 KVA (250A) EXISTING PEAK DEMAND 33 KVA (40 A) NEC DEMAND FACTOR x 125% NEC CORRECTED PEAK DEMAND LOAD 41 KVA LOAD ADDED PANEL"CL2A" 19 KVA PANEL"ELBUPS"(55 KVA x 125%) 69 KVA LOAD REMOVED RECEPTACLES(QTY 43) 8 KVA NEW TOTAL LOAD 121 KVA N 0 4' 8' 16' IEB SCALE:1/8"= V-0" key plan sheet title ELECTRICAL SCHEDULES sheet number E7O2 -I This document is the property of Heery International,Inc.and Heery International Inc.retains all drawn by NCIH checked by NCW Caton, Ruma & Assoc. FILENAME:P:\VVMC\2014-130 CATH LAB REMODEL\CAD\ELEC\P-ES.DWG _ E702 PLOT: 09/18/2014 © 9:38am REV: 09/17/2014 CAD: NWondel XREF: tb.dwg rights therein,including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. identified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc.