B14-0240_E801_1414509600.pdf
F 1,4 s ' ict rig 11211:e._ 6477 -#40)Imo 10),:b. 10/28/14 DOUBLE NUT, ALL—THREAD TO 1 I I TYPICAL FIRE/SMOKE DAMPER UNISTRUT 1 1 HEERY design 120 VOLT AIM , AIM AIM GENERAL NOTES: �' PROVIDE UNISTRUT SUPPORTS SOURCE O 1. SEE MECHANICAL PLAN DRAWING FOR ACTUAL LOCATION AND INSERT RUBBER PLUG THIS SPANNING BETWEEN BAR JOISTS. 01_ QUANTITIES OF DAMPERS. END OF INLET TUBE. I I SECURELY ANCHOR TO BAR JOISTS J L J L TYPICAL FOR TWO. AIR MOVING EQUIPMENT 2. PROVIDE CONTROL MODULE AT EACH FSD DETECTOR DEVICE AS INLET TUBE HOLESANCHO\ . RSUPPORT HOLE ONLY FOR AS REQUIRED FOR STARTER/VFD ADDITIONAL STARTERS/VFD'S FOR REQUIRED. UPSTREAM OF AIRFLOW. DUCTS MORE THAN 3' WIDE TRANSFORMER KVA 4 © UNITS SERVING THE SAME SPACE PROVIDE ALL—THREAD AT T 2 ALL FOUR CORNERS Heery International 0 –I, 555 17th Street, Suite 500 FIRE ALARM • . TYPICAL FIRE/SMOKE DAMPER DRY TYPE TRANSFORMER. SEE Denver, CO 80202 AIRFLOW _ ____ PLANS FOR KVA RATING. SEE DUCT WIDTH -- - 720.946.0276 CONTROL • © DETAIL NOTES: DIRECTION SCHEDULE FOR WEIGHT AND MODULE I DIMENSIONS AOM 0 ELECTRIC/PNEUMATIC SWITCH OR ELECTRIC DAMPER , OPERATOR(TYPICAL). EP 0 OPERATOR. PROVIDE LOCAL DSCONNOECT.D WITH DAMPER N project number • © CONNECT CONTROL MODULES AND DETECTORS TO FACP FOR RETURN TUBE SLANT CUT 13026.01 III ALARM AND ANNUNCIATION SEPARATE FROM DAMPER FACE ORIENTED DOWN— PROVIDE UNISTRUT TRAPEZE • CONTROL WIRING. STREAM OF AIRFLOW. (TWO)TWO TO SUPPORT TRANSFORMER. DO NOT INSERT RUBBER DOUBLE NUT TO ALL THREAD © PROVIDE CLOSURE OF ALL ASSOCIATED FIRE/SMOKE EXPECTED AIRFLOW PLUG. VA I L VALLEY DAMPERS ON AIR MOVING EQUIPMENT SHUTDOWN. PROVIDE DIRECTION 1 r .-- MONITOR MODULE AT EACH UNIT RELATED TO THE DAMPERS 9991 Rill •ill TO MONITOR RUN STATUS OF UNIT VIA AUXILIARY CONTACTS MEDICAL CENTER IN STARTER/VFD. PROVIDE CONDUIT, WIRING AND \ FIRE ALARM CONNECTIONS. AOM CONTROL MODULE NEOPRENE SEISMIC ISOLATOR 0 4 COORDINATE AND PROGRAM AIR MOVING EQUIPMENT SERIES RSM AS MANUFACTURED DAMPERS CONTROLLED BY GENERAL ALARM: TYPICAL SHUTDOWN TO AHU'S UPON CLOSURE OF AN ASSOCIATED BY VIBRATION MOUNTING & CATH LAB MULTIPLE FIRE/SMOKE DAMPERS CONTROLLED BY A FIRE FIRE/SMOKE DAMPER WHERE NOTED ON MECHANICAL CONTROLS/AEROFLEX (TYPICAL ALARM SYSTEM WHEN A TOTAL COVERAGE SMOKE DRAWINGS AND/OR IN SPECIFICATIONS. FOUR LOCATIONS) DETECTION SYSTEM IS PROVIDED WITHIN ALL AREAS DUCT DETECTOR DETAIL SERVED BY AN HVAC SYSTEM. ACTIVATION SMOKE TRANSFORMER MOUNTING D ETAI L DETECTOR ALARM OR SMOKE DETECTOR IN AREA SERVED NO SCALE SHALL OPEN CONTACTS AND CLOSE DAMPER. NO SCALE 181 WEST MEADOW DRIVE TYPICALFIRE/SMOKE DAMPER CONTROL WIRING DIAGRAM NOTE: SEE SPECIFICATIONS FOR ADDITIONAL SUPPORT, SEISMIC AND OTHER REQUIREMENTS. VAI L, CO NO SCALE 16721.1 16721.2 16190.1A owner's project number TOP consultants/construction managers TYPICAL 9'-0" CEILING OR HIGHER 91 c s li Q © T g 1 MD 1 Y TOP ATTACHED TO STRUCTURE TYPICAL 8'-0" CEILING STRUCTURAL: AS REQUIRED Q EPQ' ? ID STRUCTURAL CONSULTANTS INC. BOTTOM OF DEVICEcl E 3400 EAST BAYAUD AVE., SUITE 300 r - - DENVER, COLORADO 80209 O o TOP OF CABINET �\ STEEL ALL THREAD N 303.399.5154 et TOP OF CABINET NOTE: ALL DEVICES INDICATED TO BE MEP: O - w IFACPI I 'CONTROL PANELS INSTALLED AT DIFFERENT MOUNTING O m MIN. > HEIGHTS AND LOCATED WITHIN ONE CATOR RUMA & ASSOCIATES, CO. STUD SPACE FROM EACH OTHER SHALL O OaO / W 1/2 W - RACEWAYS INSTALLED AS TOP OF CABINET FAA896 TABOR STREET PART OF THIS CONTRACT O TO L❑ czM — ALIGN VERTICALLY, ON THE SAME SIDE 0�(0 — — SHALL BE ATTACHED TO OF THE STUD. WHERE WALL MOUNTED LAKEWOOD, CO 80401-4700 TOP OF STRUT WITH z O ©w X — TELEPHONES OCCUR OVER LIGHT 303.232.6200 _O = = APPROVED U—CHANNEL w PB P TPTPC — I SWITCHES, VOLUME CONTROLS, ETC. STRUT FASTENER v OFFSET ONE STUD SPACE. o D ❑M S S O CR — I INTERIORS: GALLUN-SNOW GFl 1920 MARKET STREET, SPACE FOR FUTURE m O O O0 RACEWAYS F �`' d7 1 z z `° z z z z z z SUITE 201 — _ - - - - - - - - - o ? 0 0D 0D 0D 0D 0 0 DENVER, CO 80202 -- - -0X 303.433.9600 Coo r, CO c0 c0 i.f) N CV U—CHANNEL STRUT v 010 mi- .0 N seal/signature FUTURE STRUT TO BE co f 00� °O► N N co "' `' FINISHED FLOOR NOTE: ATTACHED TO EXISTING TRAPEZE SHALL BE PROVIDED STRUT ,z"e, `•F••• N,C 9 { WHEREVER TWO OR MORE •* C 1° , RACEWAYS ARE RUN ADJACENT. TYPICAL DEVICE MOUNTING HEIGHTS ' U4 " NO SCALE 41821 9.1- - ,A, NOTES: ay���� ,,,,,,,,,.A-: x� � TRAPEZE DETAIL Y�i�';;•1,.Al....,._ T L E T BOXSUPPORT DETAIL 1. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE.OU ... NO SCALE 2. WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF NO SCALE DOOR TRIM AND CEILING LINE. NOTE: SEE SPECIFICATIONS FOR ADDITIONAL issued for date SUPPORT, SEISMIC AND OTHER REQUIREMENTS. 3. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE. CONSTRUCTION — 2 DOCUMENTS JULY 08, 1 1 1 1 16143.1 2014 item date i WIDTH AS REQUIRED / / WIDTH AS REQUIRED / WIDTH AS REQUIRED 1 / WIDTH AS REQUIRED / — 1 PLAN REVIEW 07.08.2014 3/8" 1/4„ 7/16„ P A \ E L L 1 A 1/4" 1/2" VAI \ I STS I U TI ON CE \ TE 1/4" ; 1/4„ EXHAUST FA \ #1 ;1/4„ T� A \ SFO IV E � T1 A 1/4" 3/8" 3/16„ 1/4„ FED FROM MDC 1/4" FED FROM MDC 277/480V 30 4W 1600A 3/16°° 3/16" FED FROM H1A 3/16" 3/16" I2h/2" 5/16" 2 1/2" m 120/208V 30 4W 225A 3/16" 2 1/2" W 1/4" 2 1/2" W 1/4" 50, 000 AIC , 3/16" 22, 000 AIC / 3/16" 480V 30 HP 3/16" 480- 120/208V 30 4W , 1 46" 1/4" 1/4" i PH A - BROWN; PH B - ORANGE; PH C - YELLOW ' 3/32" PH A - BLACK; PH B - RED; PH C - BLUE < 3/32'„ FEEDS PANEL Li A 3/16" NEUTRAL - GRAY; GROUND - GREEN ,`3/32:: NEUTRAL - WHITE; GROUND - GREEN 3/32" 13/16" 1/2" zi / - / T SUB-DISTRIBUTION CENTER MAIN DISTRIBUTION CENTER AND BRANCH PANELBOARD UTILIZATION EQUIPMENT TRANSFORMER NAMEPLATE DETAIL NAMEPLATE DETAIL NAMEPLATE DETAIL NAMEPLATE DETAIL SCALE: FULL SCALE: FULL SCALE: FULL SCALE: FULL NOTES: NOTES: NOTES: 1. SEE SPECIFICATIONS FOR ADDITIONAL NAMEPLATE INFORMATION. 1. SEE SPECIFICATIONS FOR ADDITIONAL NAMEPLATE INFORMATION. 1. SEE SPECIFICATIONS FOR ADDITIONAL NAMEPLATE INFORMATION. NOTES: — 1. SEE SPECIFICATIONS FOR ADDITIONAL NAMEPLATE INFORMATION. N 2. REWORD NAMEPLATE FOR FIELD CONDITIONS. 2. REWORD NAMEPLATE FOR FIELD CONDITIONS. 2. REWORD NAMEPLATE FOR FIELD CONDITIONS. 3. AMP RATING SHALL INDICATE BUS RATING. 3. AMP RATING SHALL INDICATE BUS RATING. 3. HP SHALL INDICATE HORSEPOWER. 2. REWORD NAMEPLATE FOR FIELD CONDITIONS. 0 4' 8' 16' 16195.1 16195.2 16195.3 16195.5I) SCALE:1/8"= 1'-0" key plan sheet title ELECTRICAL DETAILS sheet number E 8 0 1 J This document is the property of Heery International,Inc.and Heery International Inc.retains all drawn by NCW I checked by NOW Cator, Ruma & Assoc. FILENAME:P:\VVMC\2014-130 CATH LAB REMODEL\CAD\ELEC\P—ED.DWG _ E801 PLOT: 07/03/2014 Q 3:26pm REV: 07/02/2014 CAD: NWondel XREF: tb.dwg rights therein,including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. identified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc.