Loading...
HomeMy WebLinkAboutB14-0240_E802_1414509600.pdf Wit F e is*Is lei ict mi -dr Irloir Of) 01, Afoll 10/28/14 , GROUNDING ELECTRODE CONNECT TO NEAREST •- PROVIDE SUFFICIENT CHAIN CONDUCTOR, SIZE PER GROUNDING ELECTRODE HEERY design TO ATTACH TO CONDUCTOR. NEC 250.66 �� SYSTEM PER 250.30(A)(4). FACE OF WALL • 7/8" x 5" STRUT • GROUND LUGS 1/8" DIA. HOLE TO ACCEPT EQUIPMENT GROUNDING CHAIN FOR ATTACHMENT TO CONDUCTOR TRANSFORMER HOUSING CONDUCTOR. �_ ISOLATED GROUND —1" TYPICAL SPACING DO NOT �I (WHERE REQUIRED) DISCONNECT — 2" DIA. WHITE CORE GREEN GROUND i 7/16" DIAMETER, TYPICAL MAIN GROUND PHENOLIC GROUND TAG i _ Heery International TO COLD H1 X1 X2 SUPPLY SIDE 555 17th Street, Suite 500 Denver, CO 80202 0 WATER PIPE 1/4" HIGH LETTERING WITH XO BONDING JUMPER 720.946.0276 MINIMUM OF 1/8" BETWEEN • O O O d O O . LINES. CENTERED IN TAG. H2 H3 1 C 0 i X3 • 0 0 0 0 0 0 project number 480V-3PH 120/208V-3PH I \_, 13026.01 GROUND CONDUCTOR TAG DETAIL NO SCALE PRIMARY GROUNDED CONDUCTOR SECONDARY VA IL VALLEY 1/4" x 4" x 12" COPPER NOTE: AT GROUND BAR, PROVIDE LAMACOID GROUND BAR ALL GROUNDING WORK DONE UNDER THIS CONTRACT SHALL INCLUDE THE FOLLOWING UNLESS SPECIFICALLY MEDICAL CENTER NAMEPLATE WITH 1/2" HIGH WHITE CORE EXCLUDED: LETTERS READING "GROUND BAR". MOUNT GLASTIC STAND-OFF ON WALL ADJACENT TO GROUND BAR. INSULATOR #1872-3E A. TAG ALL GROUNDING ELECTRODE CONDUCTORS AND ASSOCIATED BONDING CONDUCTORS AT THEIR POINT OF ATTACHMENT TO GROUND BUS AND GROUNDING ELECTRODE (WHERE POSSIBLE) WITH A ROUND WHITE CORE. CATH LAB GREEN PHENOLIC NAMEPLATE AS SHOWN IN DETAIL 'A'. B. IDENTIFY ABOVE REFERENCED CONDUCTORS WITH 6" BAND OF GREEN TAPE AT EACH END AND AT 10' GROUND BAR DETAIL INTERVALS WHERE RUN EXPOSED. STENCIL CONDUITS CONTAINING THESE CONDUCTORS "MAIN GROUND" IN TRANSFORMER GROUNDING DETAIL GREEN KROY LETTERS. 1/2" DIAMETER OF CONDUIT IN HEIGHT. NO SCALE NO SCALE C. SHOW GROUNDING ELECTRODE SYSTEM CONNECTIONS BY IDENTIFYING (ON THE RECORD DRAWING MARK-UPS) WHERE (ROOM NO. AND/OR NAME) AND TO WHAT (ROD, WATER PIPE, GROUND BUS, ETC.) THEY TERMINATE. 181 WEST MEADOW DRIVE VAIL, CO 16452.2 16195.8 16452.1 owner's project number f CONDUIT FROM MOTOR STARTER CONTAINING POWER AND GROUND WIRE METAL STUD TRACK TO consultants/construction managers SUPPORT CONDUITS BETWEEN ........\....-""".............................................> WALL STUDS DISCONNECT SWITCH WHERE SHOWN STRUCTURAL: ADJACENT ON PLAN, SIZE PER MECHANICAL 1" EMT WITH EQUIPMENT SCHEDULE-MOUNT SECURELY. - STRUCTURAL CONSULTANTS INC. INSULATED THROAT 3400 EAST BAYAUD AVE., SUITE 300 2 PIPE SUPPORT OR TWO UNISTRUT • _ DENVER, COLORADO 80209 3/4" EMT WITH HEAVY GUAGE CHANNELS. - 303.399.5154 --____ INSULATED THROAT MEP: TWO LOCKS IF INNER DOOR ' CATOR RUMA & ASSOCIATES, CO. IS OVER 36" HIGH. 896 TABOR STREET CL / FLUSH LATCH AND LOCK 0 O 303.2 2 60200 CO 80401-4700 INTERIORS: CCTV 11111 . . TELE/DATA` 111111111110. 4 GALLUN-SNOW CONCEALED HINGE (TYPICAL) ® ® 1920 MARKET STREET, � FA` _ SUITE 201 IT DENVER, CO 80202 BAS` i 303.433.9600 111111 111144 FINISHED FLOOR HH I I NURSE CAL FLANGES FASTENED TO FLOOR seal/signature PVC COVERED FLEXIBLE CONNECTION /' :` ".. o ` )- // // PVC 0 0— 1/4-20—LARGE HEAD CONTAINING POWER CIRCUIT & GROUND WIRES, o Q='.-' f` SLOTTED SCREWS PROVIDE EXTRA SLACK TO ALLOW ROTATING t ;'U : t (TYPICAL) NOTE: MOTOR 90' FOR MAINTENANCE WITHOUT :-..J 41821 1. FASTEN EMT TO METAL TRACK USING 2 HOLE STRAPS & TEK SCREWS. BREAKING ELECTRICAL CONNECTION. 7i 0 cam' ""', �� 2. PAINT CONDUIT SLEEVES PER SPECIFICATION COLOR CODE SCHEME. q.,'..,. . . HINGED TRIM TO BOX PANEL FRONT TYPICAL PATIENT ROOM CONNECTION TO a�=�` `` � G: NO SCALE NOTES: PENETRATIONS DETAIL FLOOR MOUNTED MOTORS issued for date 1. ALL BOLTS SHALL HAVE LARGE (3/8") ROUND HEAD. NO WASHERS ALLOWED NO SCALE NO SCALE 2. TYPICAL FOR ALL 120/208V BRANCH PANELBOARDS. REQUIREMENTS. 16142.1 SPECIFICATIONS FOR ADDITIONAL SUPPORT, SEISMIC AND OTHER CONSTRUCTION 16470.1A 16135.4 DOCUMENTS 2ULY 08, 2014 item date 1 PLAN REVIEW 07.08.2014 N 0 4' 8' 16' lii ET) SCALE:1/8"= 1'-0" key plan sheet title ELECTRICAL DETAILS sheet number E 8 0 2 J This document is the property of Heery International,Inc.and Heery International Inc.retains all drawn by NCW I checked by NCW Cator, Ruma & Assoc. FILENAME:P:\VVMC\2014-130 CATH LAB REMODEL\CAD\ELEC\P-ED.DWG _ E802 PLOT: 07/03/2014 © 3:26pm REV: 07/02/2014 CAD: NWondel XREF: tb.dwg rights therein,including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. identified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc.