Loading...
HomeMy WebLinkAboutB14-0240_M701_1414509600.pdf Ifti OF 4kit s 1 1d iiillt.p ng cc ing AIR DEVICE SCHEDULE N laoll PLUMBING FIXTURE & EQUIPMENT SCHEDULE DESIG. MFR. TYPE MODEL FRAME MATERIAL FINISH DAMPER REMARKS TYPE 1 0/28/1 4 ELECTRICAL A TITUS CEILING SUPPLY TDV NOTE 4 STEEL WHITE NONE 1 FIXTURE FITTINGS ACCESSORY LEED CONNECTIONS SYMBOL REQUIREMENTS CEILING FIXTURE NAME MANUFACTURER MODEL TYPE SIZE MANUFACTURER MODEL SUPPLY I.R./BATTERY GPM WASTE VENT CW HW REMARKS B TITUS EXHAUST/RETURN PAR NOTE 4 STEEL/ALUMINUM WHITE NONE 1,2 HEERY design HP OR GPF FLOOR SET, RE:ARCH.DWGS FOR MTG. HT.&LOC.PROVIDE C TITUS LAMINAR HEPA TLF-HEPA NOTE 4 ALUMINUM WHITE NONE 1,3 WC-1 WATER CLOSET AMERICAN STANDARD 3043.102 SIPHON JET ELONGATED SLOAN, ROYAL 111-YO N/A 4" 2" 1" N/A AMERICAN STANDARD 17"RIM HT. 1.6 GPF BOWL 5901.110 TOILET SEAT D TITUS SIDEWALL RETURN 350RL NOTE 4 STEEL WHITE NONE 1 L-1 WALL MOUNTED,VITREOUS T&S, B-0892-01 REMARKS: LAVATORY AMERICAN STANDARD 0355.012 20-1/2"X 18-1/4" RE:SPEC 2" 1 1/2" 1/2" 1/2" RE:ARCH.DWGS FOR MTG.HT.&LOC. A (ADA) CHINA BRASS W/B-0199-21 1. PROVIDE MODULE SIZE TO FIT CEILING TYPE;SEE PLANS FOR NECK SIZES. 2. PROVIDE ALUMINUM MATERIALS FOR ALL WET AREAS. 3. PROVIDE WITH HEPA FILTER. Heery International UNDERCOUNTER,VITREOUS T&S, B-0892-01 4.COORDINATE WITH ARCHITECTURAL PLANS FOR LAY-IN VS SURFACE MOUNT FRAMES. L-2 LAVATORY AMERICAN STANDARD OVALYN 0495.221 17 1/8"X 14 1/8" RE:SPEC 2" 1 1/2" 1/2" 1/2" RE:ARCH.DWGS FOR MTG.HT.&LOC. ####...... ••# P' ,iC\2014- • Cath L.• '- odel\ -• ech\M •-• les\[M- I '-130.x1 • 2-1 Ai • 555 17th Street, Suite 500 CHINA BRASS W/B-0199-21 Denver, CO 80202 . TERMINAL BOX SCHEDULE (HOT WATER HEAT) 720.946.0276 L-3 LAVATORY AMERICAN STANDARD OVALYN 0495.221 UNDERCOUNTER,VITREOUS 17 1/8"X 14 1/8" T&S, B-0892-01 RE:SPEC 2" 1 1/2" 1/2" 1/2" RE:ARCH.DWGS FOR MTG.HT.&LOC. CHINA BRASS W/B-0199-21 INTERIOR AIR PRESS COOLING DESIGN CFM HEATING HEATING WATER COIL DATA MODULATING DESIG OR MFR MODEL INLET DROP MAX MAXIMUM MINIMUM DESIGN CFM EAT LAT MBH GPM WATER EWT CONTROL REMARKS PERIMETER DIA. (IN WC) ELEV FT ELEV FT ELEV FT °F °F P.D.MAX °F VALVE TYPE project number L-4 LAVATORY AMERICAN STANDARD 0355.012 WALL MOUNTED,VITREOUS 20-1/2"X 18-1/4" SLOAN OPTIMA RE:SPEC I.R BATTERY 2" 1 1/2" 1/2" 1/2" RE:ARCH.DWGS FOR MTG.HT.&LOC. ZONE (IN.) (SEA LEVEL) 8150 8150 8150 (FT WC) 13026.01 CHINA EBF-650-BDT-ETF 201 PERIMETER PRICE SDV 8 8 0.64 230 N/A 230 55 90 7.1 0.6 3.00 180 2-WAY ALL S-1 2 COMPT.SINK ELKAY DLR432210 W/ SELF-RIMMING,STAINLESS 43"X 22" T&S, B-2855 RE:SPEC 2" 1 1/2" 1/2" 1/2" RE:ARCH.DWGS FOR MTG.LOC. 3-HOLE PUNCH STEEL X 10" BRASS 202 PERIMETER PRICE SDV 8 8 0.64 230 N/A 230 55 90 7.1 0.6 3.00 180 2-WAY ALL VAIL VALLEY FLUSHING RIM WALL HUNG, SLOAN(ROYAL), SLOAN 117, 203 PERIMETER PRICE SDV 8 8 0.64 230 N/A 230 55 90 7.1 0.6 3.00 180 2-WAY ALL MEDICAL CENTER CSS-1 SERVICE SINK AMERICAN STANDARD 9512.013 BLOW OUT FLUSHING ACTION, 24 1/2"X 20" T&S BRASS, T&S B-0665-BSTP N/A 4" 2" 1" N/A RE:ARCH. DWGS FOR MTG.HT.&LOC. WALL MTD. AND AMERICAN STANDARD AM.STD.7880.024 • 204 PERIMETER PRICE SDV 8 8 0.64 230 N/A 230 55 90 7.1 0.6 3.00 180 2-WAY ALL MSB-1 TERRAZO FLORESTONE 90/91 /92 WALL INSTALLATION 24"X 24" T&S, B-0665-BSTP N/A 3" 2" 1/2" 1/2" RE:ARCH.DWGS FOR MTG.HT.&LOC. CATH LAB MOP SERVICE BASIN FIAT TSB 3000/3010 SERIES X12" BRASS 205 PERIMETER PRICE SDV 8 8 0.64 160 N/A 160 55 90 5.0 0.5 3.00 180 2-WAY ALL 4-5000VT-X SHOWER VALVE 206 INTERIOR PRICE SDV 8 8 0.64 460 N/A 460 55 80 10.2 0.5 3.00 180 2-WAY ALL SH-1 TILED SHOWER BY PATIENT TOILET ROOM WITH H303-V HAND SPRAY(30" - (ADA) ARCHITECT W/HAND HELD SHOWER SYMMONS BAR)W/ALSONS 6300WBX N/A 2" 1 1/2" 1/2" 1/2" RE:ARCH. DWGS FOR MTG.HT.&LOC. 207 INTERIOR PRICE SDV 8 8 0.64 300 N/A 300 55 80 6.6 0.5 3.00 180 2-WAY ALL HEAD SLIDE.PROVIDE WITH 1.5 GPM FLOW RESTRICTOR 181 WEST MEADOW DRIVE 208 INTERIOR PRICE SDV8 8 0.64 365 N/A 365 55 80 I 8.1 0.5 3.00 180 2-WAY ALL VAIL, CO BT-1 2461.002 or AMERICAST BRAND 32"X 60" 1-3170VT-H401-V RE:PLANS FOR RT OR LET SIDE DRAIN OUTLET.SPECIFY GRIP 209 PERIMETER PRICE SDV 8 8 0.64 150 N/A 150 55 90 4.6 0.5 3.00 180 2-WAY ALL (ADA) BATH TUB AMERICAN STANDARD 2460.002 ENGINEERED X 17 3/4" SYMMONS W/B30 BAR N/A 2" 1 1/2" 1/2" 1/2" RAILS.ADA:SEAT AT HEAD END MATERIAL owner's project number 210 INTERIOR PRICE SDV 8 8 0.64 350 N/A 350 55 80 7.7 0.5 3.00 180 2-WAY ALL SS-1 SCRUB SINK OFCI STERIS FLEXMATIC WALL MOUNTED STAINLESS 2" 1 1/2" 1/2" 1/2" RE:ARCH.DWGS FOR MTG.HT.&LOC.OWNER STEEL FURNISHED,CONTRACTOR INSTALLED. 211 INTERIOR PRICE SDV 8 8 0.64 450 N/A 450 55 80 10.0 0.5 3.00 180 2-WAY ALL consultants/construction managers FS-1 FLOOR SINK JAY R.SMITH 3101 CAST IRON FLOOR SINK W/ 8 1/2" N/A N/A N/A RE: 2" - ACID RESISTANT ENAMEL COATED,1/2 GRATE 212 INTERIOR PRICE SDV 16 16 1.00 2,800 N/A 2,800 55 80 61.9 0.5 9.00 180 2-WAY ALL BUCKET STRAINER SQ. PLANS MIN. STRUCTURAL: • STRUCTURAL CONSULTANTS INC. 213 INTERIOR PRICE SDV 8 8 0.64 150 N/A 150 55 80 3.3 0.5 3.00 180 2-WAY ALL 3400 EAST BAYAUD AVE., SUITE 300 TD-1 SHOWER TRENCH STAINLESS STEEL TRENCH 2" 2" PROVIDE WITH STRAINER,SPACERS AND LEVELING AND QUICKDRAIN PROLINE PLD57 57" N/A N/A N/A REQUIREMENTS APPLYING TO ALL TERMINAL BOXES: 6,105 0 6.9 DRAIN DRAIN MIN. MIN. PLACEMENT BRACKETS.RE:ARCH.DWGS FOR LOC. DENVER, COLORADO 80209 A. PROVIDE BOX SELECTION TO MEET LAT, DESIGN CFM AND HEATING MBH. FINAL GPM SHALL BE SET DURING BALANCING TO FLOW RATES IN LISTED PRODUCT DATA SUBMITTALS. 303.399.51 54 B. MAXIMUM STATIC PRESSURE IS BASED ON WIDE OPEN UNIT AT MAXIMUM FLOW FOR TERMINAL BOX WITH 2-ROW COIL. MEP: TD-2 SHOWER TRENCH QUICKDRAIN PROLINE PLD36 STAINLESS STEEL TRENCH 36" N/A N/A N/A 2" 2" PROVIDE WITH STRAINER,SPACERS AND LEVELING AND C. HEATING WATER SYSTEM CONTAINS 40% PROPYLENE GLYCOL. DRAIN DRAIN MIN. MIN. PLACEMENT BRACKETS.RE:ARCH.DWGS FOR LOC. D. 2-ROW HEATING COIL CONDITIONS SHOWN AND PREFERED.1-ROW COIL NOT ACCEPTABLE. CATOR RUMA & ASSOCIATES, CO. E. USE OF 3-&4-ROW COILS MUST BE SPECIFICALLY IDENTIFIED BY THE SUPPLIER&ACCEPTED BY THE ENGINEER FOR EACH LOCATION PROPOSED. 896 TABOR STREET F. TERMINAL BOX MAXIMUM AIR FLOW CAPABILITIES: 6"=450 CFM,8"=800 CFM,9"=1050 CFM,10"=1350 CFM,12"=2000 CFM,14"=3000 CFM,16"=4000 CFM&24"x16"=8000 CFM. LAKEWOOD, CO 80401-4700 1. REFER TO GENERAL SPECIFICATIONS FOR WATER CLOSETS, URINALS, LAVATORIES,SINKS AND MISC.FIXTURE REQUIREMENTS. G. MINIMUM 2-ROW COILS REQUIRED ON ALL PERIMETER BOXES. 2. GRAB BARS BY ARCHITECT. 303.232.6200 3. THIS SCHEDULE INCLUDES ITEMS THAT MAY NOT BE INCLUDED IN THE DRAWING DOCUMENTS. S440-1 REMARKS: INTERIORS: 1. VAV BOXES ARE TO BE INSTALLED FOR FUTURE VARIABLE AIRFLOW CONDITION.LOCK TERMINAL BOX OPEN AND DISABLE VOLUME DAMPER AS GALLUN-SNOW THE SYSTEM IS CONSTANT VOLUME AT THIS TIME.INSTALL CONTROL WIRING REQUIRED FOR FUTURE VARIABLE AIR VOLUME CONTROL. 1 920 MARKET STREET, FAN SCHEDULESUITE 201 9/17/2014 P:\VVMC\2014-130 Cath Lab Remodel\Cad\Mach\Mschedules\[M-2014-130.x1sx]5933-2 Term Box HW DENVER, CO 80202 CFM S.P. TIP OUTLET APPROX. ARRANGE. 303.433.9600 DESIG. MFR. MODEL FAN TYPE SERVICE AT IN.W.C. APPROX. SPEED VELOCITY MIN. DRIVE DAMPER THROAT & WEIGHT CONTROL REMARKS UNIT HEATER SCHEDULE (H YD RO N I C) 8150' AT 8150' RPM (FPM) (FPM) HP TYPE TYPE DIM. MOUNTING LBS. seal/signature BACKWARD INCLINED PROJECT DESIGN HEATING PARAMETERS ELECTRICAL SIZE(INCHES) MAX ��`R`�\�®®11Miiiiti EF-1 GREENHECK SWD VENT SET ISOLATION 600 1.5 2500 7281 714 1/2 DIRECT BDD 11 UPBLAST 80 BAS 1,2,3 DESIG. MFR MODEL CFM EWT WATER GLYCOL EAT MBH LAT GPM WATER MOTOR HP OR L W H OPER MTG CONTROL REMARKS i�\ • . 8,150 (°F) TEMP % (°F) (°F) PRESS TYPE WATTS WEIGHT HEIGHT VALVE TYPE ' Q•,,*`� / •• EF-2 GREENHECK SQ INLINE CENTRIFUGAL SMOKE 800 1 2200 6443 800 3/4 DIRECT BDD 12 INLINE 64 BAS 1,3 FEET DROP F) (FT HD)DROP (LBS) (FT) �I/� ,pN: REMARKS: 2-WAY = oe; 4 632 z• UH-201 TRANE S-18 395 180 30 40% 60 7.7 82.1 0.5 0.0 PSC 16W 9.4 14.6 15.0 26 8.0 ALL e • 1.UTILIZE ECM MOTOR.CONTROL WITH BAS. i �O°s/v/�//� ®p .�� MODULATING -� • f • .• 2.PROVIDE DISCONNECT ON UNIT. "' •••••••:• Itch \ 3.PROVIDE BACKDRAFT DAMPER(BY FAN MANUFACTURER). p:\VVMC\2014-130 Cath Lab Remodel\Cad\Meth\Mschedules\M-2014-130.xIsxS743-2 Air Cool /,//�///sS/ONA1�\\``G\\\`` 7/28/2014 9:14 [ ] REMARKS: /►111111{11 1. REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS. issued for date STEAM HUMIDIFIER SCHEDULE 2. MOTORS TO BE PROVIDED W/AUTOMATIC THERMAL OVERLOAD OR IMPENDANCE PROTECTION. 3. INTEHORIZRAL ONTALN CONSTRUCTION STEAM I ENTERING ENTERING LEAVING AIR TEMP. LBS/HR DUCT/PLENUM MAX.VAPOR TRAIL 4. HORIZONTAL DISCHARGE LOUVERS. DESIG. MFR. GENERATOR GENERATOR HUMIDIFIER CFM AT AIR TEMP. RELATIVE RELATIVE RISE CAPACITY HEIGHT AND ABSORBTION REMARKS DOCUMENTS JULY 28, MODEL KW MODEL 8150' °F HUMIDITY% HUMIDITY% °F WIDTH(IN,) DISTANCE(IN.) 2014 ULTRA-SORB 9/17/2014 6:48 P:\VVMC\2014-130 Cath Lab Remodel\Cad\Meth\Mschedules\[M-2014-130.xlsx]S830-19A UH-H20 H-1 DRISTEEM VM-30 30LV 2600 55 10 84 3.1 82.6 20/14 15 ALL ULTRA-SORB -416- -466- -466- -.1111._ -411.- item date H-2 DRISTEEM VM-8 8 LV 500 55 10 84 4 18.6 20/14 15 ALL _ _ _ _ _ - _ - _ AIR COOLED CONDENSING UNIT SCHEDULE H-3 DRISTEEM VM-12 12 ULTRA-SORB 920 55 10 84 4 36 20/14 15 ALL 1 PLAN REVIEW 07.08.2014 LV MATCHED COOLING COND. AMBIENT LOW AMBIENT _ DESIG. MFR. MODEL SYSTEM CAPACITY TEMP. TEMP. CONTROL REMARKS 2 CONSTRUCTION SET 07.28.2014 H-4 DRISTEEM VM-10 10 I L V •-B 760 55 10 I 84 3.8 26 20/14 15 ALL COMPONENT MBH AT 8150' °F °F °F 3 CCD-2 09.18.2014 REMARKS: ACCU-3 TECHNICAL 20ALS9 AHU-1 11,760 129 100 -20F ALL SYSTEMS 1.PROVIDE LOW PRESSURE STAINLESS STEEL RECTANGULAR DUCTWORK AS SCHEDULED FOR HUMIDIFIER.SEE HUMIDIFIER DETAIL. REMARKS: 2.CONDENSATE TO BE ROUTED TO POINT SHOWN ON DRAWINGS.PROVIDE DRAIN COOLER FOR CONDENSATE WASTE. - 3.REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS. 1.UTILIZE R410A REFRIGERANT 4.LOW PRESSURE STEAM PIPE SIZE TO BE VERIFIED WITH MANUFACTURER BASED ON INSTALLED PIPE LENGTH. 2.MINIMUM 11.1 EER 5.UTILIZATION OF ANY OTHER MANUFACTURER OF HUMIDIFIER MAY REQUIRE UPSIZING OF STEAM PIPING TO 3".COST TO OWNER NOT TO INCREASE IN THIS SCENARIO. 7/28/2014 9:14 P:\VVMC\2014-130 Cath Lab Remodel\Cad\Meth\Mschedules\[M-2014-130.xlsx]S743-2 Air Cool 9/9/2014 14:01 P:\VVMC\2014-130 Cath Lab Remodel\Cad\Mech\Mschedules\[M-2014-130.xlsx]S810-1 St Humid AIR HANDLING UNIT SCHEDULE FAN SECTIONS SUPPLY AIR COIL SECTIONS AIR FILTER SECTIONS UNITSIZE DESIG AREA MFR& OUTDOOR OUTSIDE AIR DESIGN CAPACITY i NO. WHEEL DRIVE RPM HP HP NO. VIBRATION NET AT ELEV MBH MBH EAT LAT REFRIG FUNCTION AREA MERV-A AIR P.D. L W H OPER CONTROL REMARKS DESIG. DUCT PRESSURE CLASSIFICATION SCHEDULE SERVED MODEL OR AIR CFM STREAM AT ELEV 8150 FEET OF DIA. TYPE (BELT/ APPROX. EACH TOTAL OF ISOLATOR SERVICE FACE 8150 FEET SENS TOTAL °F °F °F °F MATCHED COIL SF RATING CLEAN DIRTY (IN) (IN) (IN) WEIGHT INDOOR MINIMUM CFM ESP TSP FANS (IN) (AF/BI) DIRECT) FAN VFDS TYPE AREA CFM AIR DB WB DB WB SYSTEM (YES/ (IN WC) (IN WC) (LBS) CASING (IN WC) (IN WC) (SF) P.D. COMPONENT NO) I DUCT TYPE PRESSURE CLASS REMARKS (IN WC) . SUPPLY DUCT AIR SERVING CATH LAB 4" AHU-1 CATH LAB TEMTROL INDOOR 400 SUPPLY 2,800 2.00 2.40 1 14.0 BI DIRECT 3,030 1.6 1.6 1 SPRING COOLING 6 2,800 0.20 56 56 75.0 --- 55.0 --- ACCU-3 YES PRE-FILTER 6.0 7 0.30 0.50 28 46 96 1,729 BAS ALL AHU-1 CUSTOM LOW PRESSURE SUPPLY AIR DUCT 2" COMMON NOTES(APPLIES TO ALL AIR HANDLERS): UNIT SPECIFIC REMARKS: >REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS. 1. FINAL FILTRATION IS HEPA FILTER(MERV 13 MINIMUM)PROVIDED IN LAMINAR FLOW GRILLES.SEE AIR DEVICE SCHEDULE. ALL RETURN, EXHAUST,OUTSIDE AIR ETC. 2" >UNIT HEIGHT DOES NOT INCLUDE HEIGHT OF CURB. >PROVIDE BASE RAIL OR CURB HEIGHT TO ACCOMMODATE CONDENSATE DRAIN P-TRAP. 7/28/2014 9:14 P:\VVMC\2014-130 Cath Lab Remodel\Cad\Mech\Mschedules\[M-2014-130.xlsx]5743-2 Air Cool >MINIMUM 2-ROW HEATING COIL. >MINIMUM 6-ROW COOLING COIL. 7/28/2014 9.14 P:\VVMC\2014-130 Cath Lab Remodel\Cad\Mech\Mschedules\[M-2014-130.xlsx]S743-2 Air Cool N 0 4' 8' 16' DUCTLESS SPLIT DX SYSTEM SCHEDULE1E1)1 SCALE:1/8"= 1'-0" INDOOR UNIT OUTDOOR UNIT SUPPLYFAN COOLING COIL-REFRIGERANT(AHRI) FILTER SIZE(INCHES) COOLING CAPACITY HEATING CAPACITY-HEAT PUMP ELECTRIC I AHRI SOUND REFRIGERANT SIZE(INCHES) DESIG MANUFACTURER MODEL MOUNTING CFM FAN HP OR SOUND TOTAL SENS SENS. ENTERING AIR STYLE TYPE L W H OPER POWER SOURCE REMARKS NOMINAL TOTAL AMBIENT LOW MBH MBH AHRI HEAT EFF POWER TYPE CHARGE L W H OPER MANUFACTURER MODEL OPERATING CONTROL REMARKS DESIG. STYLE (SL) SPEED WATTS POWER MBH HEAT MBH DB WB WEIGHT COMMENT TONS MBH AIR AMBIENT AT 47°F AT 17°F HSPF (KW) SEER (dBA) (LBS) WEIGHT FUNCTION (dBA) (SL) RATIO (SL) (°F) (°F) (LBS) (SL) (SL) (°F) (°F) AMBIENT AMBIENT (LBS) AC-1 MITSUBISHI PKA-A18HA HIGH WALL 425 HIGH 30W 43 18.0 0.68 12.2 80 67 WASH-ABLE SYNTHETIC 35.4 9.9 11.7 49 POWER FROM LINE 1.0 18.0 105°F 0°F ---- 15.3 48 R410A 12.1 31.5 23.7 91 MITSUBISHI PUY-A18NHA COOLING ONLY WALL MTD WIRED REMOTE ---- ---- ---- ACCU-1 VOLTAGE SOURCE CONTROLLER AC-2 MITSUBISHI PKA-A24KA HIGH WALL 775 HIGH 56W 45 24.0 0.77 18.5 80 67 WASH-ABLE SYNTHETIC 46.2 11.7 14.4 46 POWER FROM LINE 2.0 24.0 105°F 0°F ---- ---- ---- ---- 17.0 48 R410A 14.2 37.4 37.2 165 MITSUBISHI PUY-A24NHA COOLING ONLY WALL MTD WIRED REMOTE ACCU-2 VOLTAGE SOURCE CONTROLLER REMARKS: GENERAL: UNITS SUPPLIED ON THE PROJECT SHALL BE THE MOST RECENT SERIES CURRENTLY MANUFACTURED. 1. REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS. key plan 2. REFRIGERANT CHARGE VARIES DEPENDENT UPON SIZE&LENGTH OF RUN OF PIPING. sheet title 3. PROVIDE CONDENSATE PUMP. 4. PROVIDE WIND BAFFLE TO ALLOW LOW AMBIENT PERFORMANCE AT-20F. 5.PROVIDE WALL MOUNTING BRACKETS MECHANICAL 6.UNIT WILL OPERATE AT 8150 FT ELEVATION. SCHEDULES 7/28/2014 9:14 P:\VVMC\2014-130 Cath Lab Remodel\Cad\Mech\Mschedules\[M-2014-130.xlsx]5743-2 Air Cool sheet number M701 J This document is the property of Heery International,Inc.and Heery International Inc.retains all drawn by JDD I checked by WAT Caton, Ruma & Assoc. FILENAME:P: VVMC 2014-130 CATH LAB REMODEL CAD MECH P-MLSD.DWG _ M701 PLOT: 09/17/2014 Q 4:46pm REV: 09/17/2014 CAD: JDickerson XREF: tb.dw S743-1 DUCTLESSSPLIT.dw S743-2 ACCU.dw S782-1 AHU.dw S810-1 ST HUMID.dw S850-1 FAN.dw S932-1 AIR DVC.dw S440-1 PLMBG FIXT.dw S891-1 DUCT PSR.dw S933-2 TERM BOX HW.dw 5830-19A UH-H2O.dw rights therein,including copyrights. It may only be used in a manner consistent with Heery P9 9 9 9 9 9 9 9 9 9 9 International Int.'s rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. identified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc.