Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B14-0240_M802_1414509600.pdf
olt F pja 40,00* 44 illitirils ic ict mi 0,4,7 0), lgoll 10/28/14 , NOTE: RA BALANCING DAMPER COORDINATE INSTALLATION OF TERMINAL BOX STRAP HANGER SCREWED HEERY OA BALANCING DAMPER SUPPORT FROM WITH CEILING GRID TO ASSURE CLEAR ACCESS TO SIDE. DON'T BLOCK 20/14 SA design OVERHEAD STRUCTURE A TO ACCESS PANELS. ACCESS SIDE OR BOTTOM. JI .✓' PROVIDE 3-POINT DON'T TURN STRAPS / 28/14 RA ti N GUY T$WIRRE SUPPORT 41 UNISTRUT LOW PRESSURE DISCHARGE I( I UNDER BOX. J FOR SIZE �� 36" BETWEEN BEAMS ABOVE ROOF \ ] 12/10 OA BRACKET UPPER STACK I ` — - A°� TO DISCHARGE DUCT ---"*"."--- / �� �, / SA J I� I II 15'-0" TOTAL AROUND1" GAP ALL .�r rr1 ��'' Heery International 40/28 MIXED AIR- PLENUM MECH. 273 \ I I EXHAUST I I STACK HEIGHT B �� VAV BOX 555 17th Street, Suite 500 _____7 \ iii FAN iii \ \ A FLEXIBLE CONNECTION i /� N, I I �` APPROX. OUTLET —� /DUCT Denver, CO 80202 40/28 AIR BLENDER _ SUPPORT 720.946.0276 `II _ SIZE: C"xD" 414 ' ACCESS a a FLEX CONNECTION r ` / 40/28 MIXED AIR�- DOORS EXHAUST - FAN SEE PLAN RUBBER IN SHEAR FAN __ I project number FOR SIZES VIBRATION ISOLATORSL < 13026.01 HALL C295C 0 // 7 CEILING ISOLATION u o / PER SPECS.----___LN Imo) SEE ARCH. FOR TRANSITION AS REQUIRED / J ACCESS ��� ROOF DETAILS SEE FLOOR PLAN - HVAC VAIL VALLEY // DOORS u� 1 ROOF CUPREFABRIRBTED X1IL\ o .... / / X / // CONDENSATE EXHAUST GRILLE a j �TO FLOOR SINK REMOVABLE CORE MEDICAL CENTER o FLEXIBLE CONNECTION C I I 2 PROVIDE DRAIN AT / 30" BOTTOM OF FAN SCROLL CATH L A B FULL SIZE DRAIN PAN PROVIDE MINIMUM 30" CLEAR REMOVABLE FILTER SECTION CONCRETE CURB CONTROL PANEL PANEL ACCESS ON CONTROL 3 DIAMETERS 10/10 ACCESS PANEL SIDE OF TERMINAL BOX. STRAIGHT DUCT ON BOTTOM SIDE AIR HANDLING UNIT AHU - 1 DETAIL AND SECTION IN -LINE EXHAUST FAN DETAIL ROOF EXHAUST FAN DETAIL TERMINAL BOX DETAIL 181 VAIL`, CO ESTMEADOW DRIVE SCALE: NONE SCALE: NONE 850-4 SCALE: NONE 850-1 SCALE: NONE owner's project number z- DUCT INSULATION AND 1 TALLA •N NOT REPAIR ALL FIELD CUTS JACKETING PER M.C. SHALL PROVIDE & INSTALL AND WELDS WITH ZINC SPECIFICATIONS ADDITIONAL STEEL MULLIONS PER RICH PAINT, FINISH WITH STEEL FIRE DAMPER SLEEVE, MFR INSTALLATION INSTRUCTIONS consultants/construction managers TWO COATS OF OUTDOOR PROVIDE SLEEVE GAUGE FOR MULTIPLE FIRE DAMPER FINISH PAINT AS SELECTED _ _ THICKNESS PER MFR'S ASSEMBLIES. BY ARCHITECT INSTALLATION INSTRUCTIONS / MAINTAIN EXPANSION STRUCTURAL: INSULATE RUN-OUT PER !� CLEARANCE PER MFR'S STRUCTURAL CONSULTANTS INC. MAIN DUCT 16 GA. SHEET METAL SPEICIFCATIONS - SUPPLY AIR FLOW HOLD DOWN STRAP d e INSTALLATION INSTRUCTIONS 3400 EASTAVE., SUITE 300 SECURED W/SHEET BELLMOUTH TYPE SPIN-IN SUPPORT FROM OVERHEAD <J DENVER, COLORADO 80209 METAL SCREW WITH BUTTERFLY TYPE MVD, c EXTEND QUADRANT HANDLE STRUCTURE 303.399.5154 f•- FASTENERBREAKAWAY MEP: I= _ THRU INSULATION AND SEAL ` BOTH SIDES OF AROUND INSULATION. FLEXIBLE DUCT (MAX. 6'-0") ' DAMPER SLEEVE CATOR RUMA & ASSOCIATES, CO. 1 -.4.- 1 \ SUPPORT ® 3'-0" O.C., ` CHANNEL STRUT. HOT INSULATED PER SPECIFICATIONS 896 TABOR STREET DIPPED GALVANIZED SHEET METAL " �' FIRE DAMPER LAKEWOOD, CO 80401-4700 AFTER FABRICATION DUCTWORK, �� 7 LONG RADIUS AIR FLOW INSULATED PERIt I 303.232.6200 Q SPECIFICATIONS RETARNT R o 45' MAXIMUM PROVIDE MULTIPLE ACCESS DOORS INTERIORS: FOR DUCTWORK 60" OR WIDER OR GALLUN-SNOW AIR FLOW STAINLESS STEEL WORM ON SIDE OF DUCT WHEN REQUIRED 1920 MARKET STREET, PRE-FABRICATED �f GEAR CLAMP ON BOTH TO PROVIDE ADEQUATE ACCESS TO 3/16" WELDED SOLE EQUIPMENT RAIL CEILING .� f THE FLEX DUCT JACKET FIRE DAMPER SUITE 201 � A PLATE AND ` SUPPORT ANCHOR AND INNER CORE. ATTACHMENT BOLTS TO STRUCTURE PER DENVER, CO 80202 BRANCH DUCT OP- MFR'S INSTRUCTIONS 1 1 I `� i ' 303.433.9600 �� Im ml DIAGONAL BRACING Im I 1 RE: ARCH. FOR %OR ISI WATER PROOFIFING INGL ANDAY-IN AIR T- AR R AY-IN FRAM ORAHEDUCT RIZONTAL A FIRE DAMPERS RROM \U\1111,�������/N/ ANCHOR BOLTS, LOCATE IN DECK L B 0 L E MOUNTING/RETAINING ANGLESN. seal/signature �� AS REQUIRED BY STRUCTURAL DEVICE FOR HARD CEILING. INSTALLED PER MFR'S ABOVE TO ACCESS NEGATOR 011111111111/10/ \\ _11 qty RETURN OR ENGINEER INSTALLATION INSTRUCTIONS CLOSURE SPRING Cad;+•'�I r t '•s EXHAUST SUPPLY AIR FLOW \\\\\\\\\\\\\\\ // /0 :' s. •• AIR FLOW o NOTE: HARD CEILING INSTALLATIONS: 'f�. L. CEILING DIFFUSER SHOWN; 1. PROVIDE LAY-IN FRAME TO ALLOW AIR DEVICE TO BE NOTE: N; o° i ° a / REGISTERS AND GRILLES SIMILAR. REMOVED. VERTICAL TYPE FIRE DAMPER SHOWN. FOR = . 4 632 z• L o „ o ° a e aS 2. LOCATE MVD TO BE ACCESSIBLE. IF SPIN-IN IS NOT HORIZONTAL TYPE, TURN ASSEMBLY 90' AND s o \ a a ACCESSIBLE PROVIDE A SEPARATE MVD ACCESSIBLE BY PROVIDE W/NEGATOR CLOSURE SPRING. %-9p.'• /07-7 C./ 1 4k/s 0 Lz a REMOVING THE GRILLE IN LIEU OF THE ONE AT THE i� O,: •• •.0_,.& b. to a d 4 d Q A SPIN-IN. ���� $•x,' S�ONAL\ NOTE: DUCT SUPPORT ON EXTERNAL WALL SHALL BE PER SMACNA ROUND NECK FIRE DAMPER ►rnnunn�a DUCT TAKE-OFF DETAIL ROOF DUCT SUPPORT DETAIL AIR DEVICE DETAIL INSTALLATION DETAIL issued for date SCALE: NONE SCALE: NONE 891-5 SCALE: NONE SCALE: NONE C O N S T R U C T I O N JULY 28, DOCUMENTS �������������� 2014 HWS MAIN HWR MAIN item date ��9 MAIN LINE SHUTOFF VALVE PRESSURE GAUGE FLASHING METAL ROOF CURB 1 PLAN REVIEW 07.08.2014 CONDENSING UNIT �' - TERMINATE 1" VENT THROUGH I—HWR PRESSURE SWITCH 2 CONSTRUCTION SET 07.28.2014 ROOFWITH GOOSENECK AT X" CONDENSTATE DN IN WALL ROOF Li MIN.IN. 24" ABOVE ROOF. 3 CCD-2 09.18.2014 HWS -1111m,-- r SILICON CAULKING I UNION OR FLANGE 1 1 I SLEEVED PENETRATION AROUND PERIMETER FOR STEEL PIPE COUNTER TOP r TO SYSTEM (--PS O OF AHU ONLY. NOT REQUIRED — 1 r•-.- 1/2"LOW PRESSURE VENT L o I FOR COPPER (TYP.) (GAS MAIN) I#1 GAS MAIN LINE COUNTER FLASHING FLASHING I _• J / UNION ' CANT. STRIP — 18 GAUGE SIGNAL WIREN // LINE PRESSURE RELIEF VALVE �fh TO MAP. SEE PLANS FO1� / _ MORE INFO MANIFOLD —SIH 5m1 PLASTICg- 1/2"HIGH PRESSURE VENT MANIFOLD HEADER. INSTALL ROOF CURB 2"W TO WALL II ____ -. _ LEVEL AND PLUMB I �.�. 4" LIGHT WT. CONCRETEh I N II COIL J HEADER SUPPORT BOLTED 4" HIGH DENSITY INSULATION 8" 14 14 I • I } } IJ IL TO WALL '- ;&_ L LIT' I) TO -1-s_,' _ X36"LONG PIGTAIL (TYP.) FLOOR iIi ( I CYLINDER SHUTOFF VALVE fi ... _ AND CHECK VALVE NOTE:ROOF CURB AND FLASHING SHALL BE INSTALLED * --�3/4" .....J _ •'- _ �\ —2x2 MANIFOLD SHOWN. ce ix BY THE NATIONAL ROOFING CONTRACTORS ASSOC. w w w w EXPAND TO ADDITIONAL RECOMMENDATIONS AND DETAILS. 4'-7" z z z z CYLINDERS AS SHOWN U 3-U >- U DASHED. co to to to CONDENSATE WASTE TO 0 0 0 6 PROVIDE CHAIN SUPPORT ROOF MOUNTED CONDENSING HOT WATER UNIT FOR EACH CYLINDER U N IT SUPPORT ISOLATION DETAIL HEATER PIPING DETAIL SINK TAILPIECE PIPING DETAILATTACHED TO WALL. N F L 0 0 R , t l a l , i l 1 a 0 4' 8' 16' SCALE: NONE SCALE: NONE 830-08 SCALE: NONE IliIle) r I I r �a ELECTRICAL NOTE: SCALE:1/8"= 1'-0" FLOOR 0'-11" 0'-11" 0'-11" 0'-11" 0'-11" 0'-11" 0'-11" 0'-9" PROVIDE 110V RECEPTICAL TO N20 MANIFOLDS FOR BOTTLE BEAM FRONT VIEW WARMER. 3 , r0'-11"r 0'-11" 0'-11"r 0'-11" 0'-11"r 0'-11"r 0'-11"r 0'-9"" LI a • I � I— a� a a a 0 a . a WALL 1p 1 4 . . iw ( (-iii:.'),‘ � \` I l/ 1 �-� f ,�, 11 \I I l/ - �, I I V I 2x2 MANIFOLD SHOWN. � ', ', \ � EXPAND TO ADDITIONAL , _ CYLINDERS AS SHOWN - o;11 DASHED. RADIUS a179 r7 \(\ ' 0 4 6" NOTE: MANIFOLD PLAN VIEW TYPICAL CYLINDER sheet title DETAIL TYPICAL OF NITROUS OXIDE, CO2, AND NITROGEN MANIFOLDS. MECHANICAL key plan TYPICAL MEDICAL GAS MANIFOLD DETAIL DUCT PASSING UNDER BEAM DETAILS SCALE NONE SCALE: NONE w w w sheet number M 8 0 2 J This document is the property of Heery International,Inc.and Heery International Inc.retains all drawn by JDD I checked by WAT rights therein,including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. identified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc.