HomeMy WebLinkAboutB14-0240_P402_1414509660.pdf F p4, s °"ole,„ •41/41 10:0 4 © O 823/61978 33/x19 3/,t B3/161978CO. 4V - - - 9 NEW KEY NOTES: laol IP I 1 Q PROVIDE 3/4"N (REGULATED). CONNECT TO CEILING MOUNTED GAS BOOM PER 10/28/14 BOOM MANUFACTURERS INSTRUCTIONS. I I © PROVIDE 02, VAC, AND MA OUTLETS AND PIPING TO NEW CASEWORK HEADWALL. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT OUTLET COUNTS o I"iEEdesia n LOCATIONS AND ELEVATIONS. V I 1 Q ADD ADDITIONAL 02, VAC, AND MA OUTLETS AND PIPING TO NEW CASEWORK HEADWALL. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT OUTLET COUNTS LOCATIONS AND ELEVATIONS. I I y * Q REPLACE EXISTING ZONE VALVE BOX WITH NEW ZONE VALVE BOX INCLUDING I ADDITIONAL MA VALVE. REPLACE AREA ALARM PANEL FOR THIS ZVB TO ---LI--1. ====d I INCLUDE NEW MEDICAL AIR SUPPLY. { n 11 �{ 1 Q REMOVE AAP SENSORS FROM SUPPLY SIDE OF MED GAS ZONE VALVE BOX Heery International IIIII 1_, _ 1 1 .�, I�j' �•. AND RECONNECT TO PATIENT SIDE OF ZONE VALVE BOX. 555 17th Street, Suite 500 256A 6 ADD ADDITIONAL 02, VAC, AND MA OUTLETS AND PIPING TO NEW CASEWORK Denver, CO 80202 CONFERENCE 2 BED ROOM HEADWALL. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT OUTLET COUNTS STAIR CFIIM255 256 I I LOCATIONS AND ELEVATIONS. 720.946.0276 3 N O 1" VAC, 1/2" MA AND 1/2" 02 DOWN THRU FLOOR AND UP TO NEW FOOT PEDESTAL. 1 1 I 8 PROVIDE NEW AREA ALARM PANEL FOR EXISTING ZONE VALVE BOX. project number O r ` nn n �, , • a; U _ ,_ 9 ROUTE 3/4"N UP THROUGH EXISTING FLOOR CORE AND CONNECT TO 13026.01 10 `•, 3/4»[] U EXISTING 1" NITROGEN PIPING ABOVE SURGERY LOUNGE. = 1 I BED ROOM I AI C216 1/2" I 10 REWORK EXISTING HEADWALLS, TAKING EXISTING OUTLETS OUT OF THE 11, EXISTING HEADWALLS AND REPLACING WITH NEW OUTLETS FOLLOWING VA I L VALLEY OA I I - I , Oo 226E ROOM ARCHITECTURAL RENOVATION. REFER TO ARCHITECT FOR EXACT LOCATIONS. - � - _1 '� _ _ _ AT MINIMUM THE FOLLOWING OUTLETS WILL BE PROVIDED PER ICU BED: (3) MEDICAL CENTER 3 02, (3) VAC AND (2) MA. MA SHALL BE 58" AFF, 02 SHALL BE 55" AFF, II II 3/ - I AND VAC SHALL BE 35" AFF. = 1 1/, ' IIMED/ I I - SUPPLY I� .4100.3/- 1 1/4" VAC, 3/4" WAGD, 1/2" MA, 1/2" N20 AND 1/2" 02 PIPING _ TO THE FOLLOWING MEDICAL GAS OUTLETS ON NORTH WALL: (2) 02, (4) CATH LA B I I I I I 1 257A I 1 VAC, (1) MA AND (1) N20. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT o OUTLET COUNTS LOCATIONS AND ELEVATIONS. 1 1 1 1 � E) ROP O I I I I O 2 BED ROOM 222 1 1 IV SUPPLY I NJ 181 WEST MEADOW DRIVE 0 10 A A = 257BII , •• RI VAIL, CO 10 - 0 Ti .A 10 , AAP MA owner's project number / 8 1 II TEMP/ ICU I '= P ' IC O I I. - I 1/2» _ I �_ 3/4" Jr[�. [ consultants/construction managers % C213 0 83/62001 - - - ��� 1 11 _ _ I CTS _ 7 STRUCTURAL: _ 1/2" MA 1 257 STRUCTURAL CONSULTANTS INC. = 1 \� 3,4" Oo 3400 EAST BAYAUD AVE., SUITE 300 02 /� �. DENVER, COLORADO 80209 ��°�ac _ L 303.399.5154 = I TIP,' ICU 1 MA / I T_MP/ ICU I 73/620 - O 1' NEGATVE PRESSUREII \� MEP: 11215 1" c, 3/ 1 -� � 1/2" c 224 CATOR RUMA & ASSOCIATES, CO. 10 1 2" g3 VAC o2 896 TABOR STREET =1 •• / ••o v6 M_ 10 A , I LAKEWOOD, CO 80401-4700 III _ .. _ air.-- 11/0' _12= 411,77..__.77. Tis�� d' o - Gam- - -1 • .1 303.232.6200 _I• 1 ,f SUPPLY/ PINTERIORS: 258 0 11 - 1 633/200 -1-� - - - - M GALLUN-SNOW - -1, 1920 MARKET STREET, ICED ROOM I _ .111,I ,- I ""�r SUITE 201 - C211 DENVER, CO 80202 0 II N II '-` STORAGE g _ 1 CASE MANAGER OFFdCE > U 262 276 303.433.9600 - II TUB Iii P 260 =_IM • - O �`��a��u1®lu�11//0 tp� seal/signature 3/4" M Y ����i �'® N "fit I / —-- 4,10,,,,,N../..0!.� �l r L �� �i — 1/2" — 1 I I � 1, I 1 i O C212 I `�' , �u� I ED ROOM O 4 632 2) I I I il 1 I I I ; _ STORAGE -' • ....,,,._...0: {` ,hq w uu 4 , n E.._. I I I I , n n it I I I, i -�II - t-a �1 53/x2001 //iipuinnmu►�����`�OPATIENT ROOM - -� I I �/209 IL• I MEDS/ 3/ NI r LINEN SOLED UTILITY Ff1::____ issued for date o- CLEAN SUPPLY`+ I HOTELING 254 V � 7 - 264 2 ¢� CONSTRUCTION f11I4Il � �� >O: VB A 263 I r__,, 2-1/2" o DOCUMENTS JULY VAC I OFFICE MA 2 BED ROOM •: :• 2 BED '��IG4» 2 BES M •f 253 \ EQUIP Ni 28, 6 211 . _ 212 213 . rl % 1 1 1°� 266RAGE 2014 PATIENT RO11 7u •.- .• 1/2» 1/2" •� - , 1" 3/4" �,� �.:� 3/4" 210 3/4"-j-1/22"13\- .. • ��, —•� , v--V 1 MA • 02 _ _ �� •• item date 0-.. 1111 I _" > 0 ---�' LO >0 l 2" TELCOM 280 r > I / I • 267 1 ' cV OFFICE CTS 0 `---' I 1 PLAN REVIEW 07.08.2014 0 252 GAAP 251 l �- 2 CONSTRUCTION SET 07.28.2014 _ 3 CCD-2 09.18.2014 1 , O ' / O O I IAAP 1/2 MA PED/ CATH/ IT 02 Iii (/_�) 110 II \ z_1/2" 02 1 EXAM 268 4" Ni�� ' II _■ l� I _ (*At - �� 1" VAC - 220 T_ J ilk41111 © ` .° % Ir I ■ . > I I I I� �1 ��111J I \ �� fid•• - �� ��_ v it ,_ 02 02 - 021 0 I I I 1 I 1 1 I 1/2" 1/2" /4" - - H-vim f __ 1/2" MA N I 1/2" MA J `` ���� 1 -- CORRIDOR n K1 OR 0 Q •••••••• ...• ���� .29:: -- .■■.- r 29UA VB I I I _ 11 I I I I I I I 1 1.�1 I _ IQQQQQn' :I.Ete V, D - - L - - - - T I :see -- — 43/x201 -- �) �� �� ry. > �� - i 1/2" 0 \ I SHOWER _ _ _ N �� EQUIP. I __ YJBLICT 1 \\ oOkhI I / �i z - kQUII 1-1/2" VAC [I � I 200A 1��..�1 C hD ,N I 1 1 269 01 ELEC. O >o O '/ 0 0 3/4»� X1/2„ 0 �� . © I © illiNI !1 I]I. I 4 i� �J I'�� 270 L �:�n MA 02— CJA 17k.' - MA �1,—BATH _ ANTE VAC — Ul 1�� c VAC PED/ OBS ►FFICE CATH LAB STAFF/_ itT PT DRESSING O201 - / 200 _ UBLIC T. 3/4, O �� 20 N� • 250 1 Q ` I i11271A271 B q F C1 VAC r_ �I I I I o• 1/2" /-1/2" •r PEL- 1 I III 1/2' N20 --® 2 HU) 1-Mry1/2„ 02 �:ED ROOM •. 2 BED ROOM —I1:• 2 BED\Big0V, im �/;..• • -'I� ....a...___,.,!.I!! _=1 I I1 :� ® KER I 208 2►■ • 205 204 203 ■ "������y!�■- -I I I �g�= ��■`,` !i ALL _ 1 • ■ —a KI��j- 12958 71 ( ) (\]v�` ISOLATION • r 'I' ( p �.,'; L : r O 1 ', 2061 0 n n� ,R� ! a `� - � � 7 I = . B _ L_ rile ,./ _,51:1_ 1 I , ,1 11 10 mi _ u u u •„,,,, N �I II, I 0 4' 8' 16' CATH LAB STORAGE CONTROL 272 PCU �9 SCALE:1/8”= 1'-0" 200C 33/62001— - 1 1 1 I Ir 11-)1 I I 1 I MEC ',NICAL 23/62001— - 1 HA 27 \...____yI TEMP STORAGE C24.0 274 ••u•• II I „ ,I I I I I I I I I I • • N20 (2x2) I o ■ RE: DETAIL 1 I I ri . . . . . u . — L. — — — — 11 11 11 11 11 11 imi 11 11 • II AUTO SWITCHOVER DOME LOADED MANIFOLD (N20) 13/ 02-,-,o1— - �I 1- I I _ I key plan ALL MED GAS BOTTLE MANIFOLDS TO MEET NFPA I sheet title 99 REQUIREMENTS FOR ALARMS AND VENTING I I I SECOND FLOOR MEDICAL GAS PLAN _ SECOND FLOOR SCALE: 1/8"=1'-0" A3/162001 83A620011200' MEDICAL GAS PLAN sheet number P4O2 _1 This document is the property of Heery International,Inc.and Heery International Inc.retains all drawn by JDD I checked by WAT Caton, Ruma & Assoc. FILENAME:P: VVMC 2014-130 CATH LAB REMODEL CAD PLBG P-PM2.DWG _ P402 PLOT: 09/17/2014 Q 4:15 m REV: 09/16/2014 CAD: JDickerson XREF: b 2.dw xb 2-SECONDFLOORFLOORPLAN.dw xb 2-SECONDFLOORDEMOLITIONPLAN.dw xb 2-EXISTINGROOMNAMESFORSHEETAF-100.dw xb 2-EXISTINGROOMNAMESFORSHEETAD100.dw tb.dw m2.dw Ke Plan.dw rights therein,including copyrights. It may only be used in a manner consistent with Heery P9 9 9 9 9 9 9 9 9 9 9 P 9 Y 9 International Inc.'-rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. identified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc.