Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B14-0240_T-102_1414509600.pdf
Ot OF p- 4 © 0 23,61978 33,61943,.. GENERAL NOTES: 83A61976 — 1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO I I \..,___/ a I REMAIN ARE DENOTED LIGHTLY. r- Igo, 1 g 2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR 1 EQUIPMENT APPEARS, TO NAL TO BEO CURION,RENTLYMINGE USEAORED BY THE NOT, UNLESS WRITTEN CONTRACTOR WHETHER AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL 10/28/14 I EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. A41\ 3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT I I EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. 4. HEERY design DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. I 5. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO 71 ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. __ 6. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH A-- _--�- MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH—IN AND � II u �� �� ORDERING MATERIALS OR EQUIPMENT. 3 3 3 Heery International �1 `I - - - ! _ - 7. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION - 555 17th Street, Suite 500 41110 WAP I, ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, 1 • 1 TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH Denver, CO 80202 O 3 JLr& ]1 1 SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, 720.946.0276 3 ' ' OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. op, WAP _ 8. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER 1 1 1 �.- _ . FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CATOR, RUMA & 3 ,' 1 ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE project number O • A� .y ` �� �� a co _ ft _ �1_ ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY 13026.01 - WORK SHOWN AS EXISTING ON THESE DRAWINGS. (0 IIU I I 1 1 WAP VAIL VALLEY o , , , I _ = TECHNOLOGY PLAN NOTES: MEDICAL CENTER ID 4111111 II WAP - &\ E - I 1•• PROVIDE 4" SQUARE OUTLET BOX AND SINGLE GANG MUD RING FOR ALL TELE/DATA I I I I1 OUTLETS. ROUTE 1" CONDUIT FROM EACH OUTLET TO ABOVE ACCESSIBLE CEILING CATH LAB UNLESS NOTED OTHERWISE. PROVIDE INSULATED THROAT CONNECTOR ON CONDUIT END. I 1 1 1 WAP 1' KEEP ALL EXPOSED CONDUITS TIGHT TO STRUCTURE. PROVIDE J—HOOK TYPE CABLE II n - A 1 SUPPORTS EVERY FOUR TO FIVE FEET TO SUPPORT CABLES IN ROUTE TO k m TELECOMMUNICATIONS ROOM. OO 1 1 n n O 2. PROVIDE 4" SQUARE OUTLET BOX AND SINGLE GANG MUD RING FOR ALL SECURITY, CCTV, AND TELEVISION OUTLETS. ROUTE 3/4" CONDUIT FROM EACH OUTLET TO ABOVE I I ACCESSIBLE CEILING UNLESS NOTED OTHERWISE. PROVIDE INSULATED THROAT 181 WEST MEADOW DRIVE _ CONNECTOR ON CONDUIT END. KEEP ALL EXPOSED CONDUITS TIGHT TO STRUCTURE. ! ' ' �� � W A �� ��� A 3• PROVIDE AN 8' SERVICE LOOP AT STATION END OF ALL CABLE RUNS. PROVIDE 30' • — ' — — — — — — — H — — — — — — — — — — — — — w — n _ I �� SERVICE LOOP AT ALL WIRELESS ACCESS POINT LOCATIONS. TERMINATE CABLE ON A 3 cr. 3 � 3 �� 3 1 SURFACE MOUNT OUTLET BOX. 1 CO 1 • I I I 1 4• HOMERUN ALL VOICE, DATA, TELEVISION, SECURITY, AND CCTV CABLES TO DESIGNATED owner's project number • �. �. I I CONTROL PANELS, PATCH PANELS, OR WALL FIELDS IN TELECOMMUNICATIONS ROOM O ` ` TEMP ICU ' I 1 LOCATED IN THE SAME ZONE. PROVIDE J-HOOK TYPE CABLE SUPPORTS IN OPEN OR TEMP/ ICU � . ACCESSIBLE CEILING SPACE AS REQUIRED TO SUPPORT CABLES IN ROUT TO CABLE 217 223 �� I [ TRAY OR CONDUIT PATHWAY TO TELECOMMUNICATIONS ROOM. ROUTE CABLE SUPPORTS consultants/construction managers 1 0 Limmj SUCH THAT CABLE VISIBILITY WILL BE MINIMIZED IN ANY OPEN CEILING AREAS. 1 4e„,. r7Cu 1 83�62�01xJ� 5. ALL MATERIALS PROVIDED FOR THE TELECOMMUNICATIONS SYSTEMS SHALL MATCH AND STRUCTURAL: �_ L 1BECOMPATIBLETOTHEEXISTINGSYSTEMS. ALLMATERIALSPROVIDEDSHALLMATCHSTRUCTURALCONSULTANTS INC. THE EXISTING EQUIPMENT IN MANUFACTURER, MODEL, AND COLOR FOR THE SPECIFIC1 1 D� 1 1 OO AREA TO BE LOCATED. COMPONENTS REQUIRED TO EXPAND THE EXISTING SYSTEMS 3400 EAST BAYAUD AVE., SUITE 300 0 WqP CAPACITY SHALL BE PROVIDED BY THE CONTRACTOR. DENVER, COLORADO 80209 " WAP TEMP/ ICU 73/620 1 I _ 6. COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL, CEILING, AND FLOOR 303.399.5154 TEMP ICU O ' I NEGATIVE PRESSURE DEVICES WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE OR SPECIALTY MEP: 216 �� EQUIPMENT SUPPLIER DRAWINGS PRIOR TO ROUGH—IN. 224 I I CATOR RUMA & ASSOCIATES, CO. WAP EP 7. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY 896 TABOR STREET 3 3 rI� P I 3 3 ADVERSE FIELD CONDITIONS PRIOR TO PERFORMING ANY WORK. l LAKEWOOD, CO 80401-4700 ID 01_77 L �� �� R� il1[1 �� �� 303.232.6200 m INTERIORS: r ih 363/s200� GALLUN-SNOW I 3% —1— b KEY NOTES: 1920 MARKET STREET, O ' ' — BIO-MED AND NURSE CALL EQUIPMENT TO BE RELOCATED TO THIS AREA. SUITE 201 IMMM PLO 0 DENVER, CO 80202 �.^��, �� STORAGE CASE MANAGER OFFICE © COORDINATE EXACT LOACTION WITH EQUIPMENT VENDORS. 303.433.9600 WAP � ,, 1 262 — 276 _ WAP ,,, I, 260 3 seal/signature 1 I WAP I El) 1 Amii l ! I I I O 11111- ,� � 1 I — �1 — � w 7 — 53/62001 PATIENT ROOM L 1�� I e n I ' ' � I 4 I I I L__.J —_ 209 3i !3 I !Ill LINEN ;SOILED UTILIT issued for date 1 NOURISH. 11 264 265 0� ..1-1 0 P ,� E. 263 0 CONSTRUCTION m H 1 I » JULY 28, DOCUMENTS1 a. Ian. ...s... AM..Inn.Ili..AMIS.Allillk..a a Illi Mb.AIIII.Malsi 2014 +30" A3+30" PATIENT ROOM +76"3P6. 3+��" 210 WAP WAP III 1 I ►� - I \ `��Ji 3, 3 3 I'm 3 3 I date I • • ■ • 25"+501" ' 25"+5e"' item II 1V �_ P// 1 �' 3 1 �I All EP3 • 11- , 11 IO 1 PLAN REVIEW 07.08.2014 I , 1 0 0 ' 1 1 1 2 CONSTRUCTION SET 07.28.2014 11 �h f1jEP 1 ' JIIIIA - RED/ CATH/ 3 CCD-2 1 �� �J • I I 1 1 — — - 09.18.2014 OE.JXAM �� 1 • I �, . i jc.,-Fic.i...., <�� L12._3 2203 -� Alellu U� 1 ; e �� Ir _ _© - - ii i i i i , �I — _1. 11111 L- 0 O I I I I I I Y A 1 WAP WAP 1 CO"IDOR 1 CORRIDOR WA7 WAP C290A C290B r.,..--1.. i . i - . - .__41—ri . . 1 _ _ . . i - - I .11A i - .a-- - - ' - I ill I 43/,6201 ill — MINIM - y�.� _ �� EQUIP. :. I L__! I - - - I __ 'UBLIC T I I �� 1 -..I I :2E I \______, � — / \ EQ1 I .,�3WAP 3200/ �>♦��u _ ICORRIDOR 269 ELEC. 1141/4 V' CI 0 0 0 10, 3 i� !!�._aL � �I 20111C295A 1/ / I���II� ]��� I _ 2704 \ I II --,_ ■ J �� 1 ED 7C7 04433:11,' I __H _ Di, PED/ OBS© OFFICE ' I I CATH LAB II I ��1�3+30" 3 PED OBS +30" „3OT PT 3i' _ STAFFDRESSINGO WAP i V 3+75" 26 AP 201 +75" O.1 200 PUBLIC 271 A T. 271 B 1 \ WAP - , 1 .I 1 ®3 3 r� bn ���r�sr�ln— HALL tom R 1 1 • / Ep iij ��u� �j 1i 'i A 1 a.- A 7ii 02958 w 1 41) �� - - - - - - - - - - - - - - :Mimi - - �1i ,,. • .r.�,� a. ,1...„„.._r •Esi ©_ - �� _1, „_ j� 111;111 .1gII �I 3 I 1L N t 1 , 1 B VIII � II III �► AI'I- f u u II I , _ .', r --r _,_ _ _M :01_16, .�� I CO 3 WAP I U 3 U i Ii 0 4' 8' 16' CATH LAB STORAGE _ le1) 1 CONTROL 272 `__J I 33/ 02si 01 SCALE:118"= 1'-0" 1 1 1 200C 11 �� 1 0 1 I 3 I ® I I MECHANICAL 23/ 02si 00-1— - I — \ I HALL 273 I �� I 1 TEMP STORAGE C295C 1 1 274 I I I I I I 1 1 1 1 1 I - -- -1—•[ - ---t, t - 1, t IwI.hw e 13r 01 I I 1 1 U 1 1 . 1 key plan I I I sheet title 4 SECOND FLOOR TECHNOLOGY PLAN SECOND FLOOR SCALE: 1/8"-,'-o"VI TECHNOLOGY PLAN sheet number T - 102 J This document is the property of Heery International,Inc.and Heery International Inc.retains all drawn by JAI checked by CMK Caton, Ruma & Assoc. FILENAME:P: VVMC 2014-130 CATH LAB REMODEL CAD TECH P—TECH2.DWG _ T-102. PLOT: 09/17/2014 © 3:07 m REV: 07/28/2014 CAD: Jlbanez XREF: b 2.dw xb 2—SECONDFLOORFLOORPLAN.dw xb 2—SECONDFLOORDEMOLITIONPLAN.dw xb 2—EXISTINGROOMNAMESFORSHEETAF-100.dw xb 2—EXISTINGROOMNAMESFORSHEETAD100.dw tb.dw wr2.dw tech2.dw rights therein,including copyrights. It may only be used in a manner consistent with Heery P9 9 9 9 9 9 9 9 9 9 9 P 9 9 International Inc.'s rights while Heery International,Inc.is providing services for the specific project Copyright©2013 by Heery International,Inc.all rights reserved. identified or referred to herein or extensions thereto. It may not be used for any other purpose WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" except with the express written agreement of,and compensation to,Heery International Inc.