HomeMy WebLinkAboutB18-0278_REV1 Approved Plans_1541103287.pdfSCALE: 1 MECHANICAL GARAGE FLOOR PLAN - NEW 1/8" = 1'-0" FLAG NOTES: EXISTING GAS TO FIRE PIT. DOMESTIC WATER SUPPLY/RETURN PIPING ROUTED FROM EXISTING LINES. COORDINATE CONNECTION LOCATIONS IN FIELD. REFER TO DETAIL C/M4.0 FOR EXTERIOR SINK WINTERIZATION VALVING. NEW GAS LINE UP TO FIRE PIT, 3/4" 70,000 BTUH NEW GAS LINE UP TO BBQ, 1", 120,000 BTUH DELETE EXISTING LOW PRESSURE GAS LINE. PROVIDE NEW PRV AND SHUT OFF AS PART OF NEW FIRE PIT ASSEMBLY. REPLACE EXISTING 3/4" 2 PSI G WITH NEW 1" 2 PSI GAS LINE UP TO FIRE PIT, 500,000 BTUH. 1 3/4" CW 3/4" HW 1/2" CW1/2" HW1/2" CW1/2" HW2 1/2" G(E) 2" G(E)G(E) 3" G(E)1/2" HWC 2 3 3 3 1-1/4” G 1-1/4” G 3/4” G CW1” GHW1” G 3/4” G MG (2 PSI)4 5 4 4 4 4 5 5 6 CWHWGHWCMG (2 PSI)4" (E)2 1/2" (E)4" (E)1 1/4" (E)GHWC2 CW (E)HW (E)HWC (E)MG (2 PSI) (E)G (E)3/4" G 6 ASI 1 Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15M2.1.DWG10.15.182:26:08 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ASI 10/12/2018 GAS LINE RFI 10/15/2018 MECHANICAL GARAGE PLAN DAL DAL M2.1 11/01/18 SCALE:1 LIGHTING FIRST FLOOR RCP PLAN - NEW 1/8" = 1'-0" 1. NEW LIGHT FIXTURES ARE OWNER-PROVIDED, CONTRACTOR INSTALLED. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR FIXTURE SPECIFICATIONS. 2. NEW LIGHTING IS EQUAL TO OR LOWER WATTAGE OF EXISTING LIGHT FIXTURES. ELECTRICAL CONTRACTOR SHALL DISCONNECT EXISTING LIGHT FIXTURES AND CONNECT NEW LIGHT TO EXISTING CIRCUIT. NOTES: 1. FIXTURE SHALL BE REPLACED WITH OWNER PROVIDED, CONTRACTOR INSTALLED FIXTURE. 2. RELOCATED LIGHTING FIXTURE. 3. SHELF LIGHTING SHALL BE REPLACED WITH OWNER PROVIDED, CONTRACTOR INSTALLED FIXTURE. REUSE EXISTING ELECTRICAL CIRCUIT TO POWER NEW FIXTURES. 4. LANDSCAPE LIGHTING SHALL BE REPLACED WITH OWNER PROVIDED, CONTRACTOR INSTALLED FIXTURE. REUSE EXISTING ELECTRICAL CIRCUIT TO POWER NEW FIXTURES. 5. NEW DOWNLIGHT SHALL BE OWNER PROVIDED, CONTRACTOR INSTALLED. EXTEND EXISTING POWER CIRCUIT TO NEW FIXTURES. FLAG NOTES:# CK CK CK SSCK (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E)(E) (E) (E)(E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 2 (E) 5 5 5 5 2 2 (E) 2 Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E3.1.DWG10.17.1810:09:45 AM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL ASI #1 10/12/2018 GAS LINE RFI 10/15/2018 ELECTRICAL ASI #2 10/17/2018 ELECTRICAL FIRST FLOOR RCP - NEW BAS MAS E3.1 X Exit sign req'd of this opening 11/01/18 SCALE:1 LIGHTING FIRST FLOOR RCP PLAN - DEMO 1/8" = 1'-0" CK CK CK SSCK 1. SALVAGE EXISTING FIXTURES FOR RELOCATION. RE: RCP ON SHEET E3.1 FOR NEW LOCATION. 2. EXISTING SHELF LIGHTING TO BE REMOVED. SALVAGE EXISTING CIRCUIT FOR REUSE. 3. EXISTING LANDSCAPE LIGHT SHALL BE REMOVED. SALVAGE EXISTING CIRCUIT FOR REUSE. FLAG NOTES:# 1. AREAS NOTED WITH HATCHING ARE FIXTURES TO BE DEMO'D. SALVAGE EXISTING ELECTRICAL CIRCUITS FOR REUSE. NOTES: 2 2 2 3 3 3 3 3 3 3 3 1 J 3 3 3 3 3 33 1 1 1 1 Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E3.0.DWG10.17.1810:09:44 AM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL ASI #1 10/12/2018 GAS LINE RFI 10/15/2018 ELECTRICAL ASI #2 10/17/2018 ELECTRICAL FIRST FLOOR RCP - DEMO BAS MAS E3.0 X Exit sign req'd over this door 11/01/18 SCALE: 1 ELECTRICAL FIRST FLOOR FLOOR PLAN - NEW 1/8"= 1'-0" 1. METER PANEL 'L11' IN ELECTRICAL ROOM 110 FOR 30 DAYS PER NEC 220.87 TO DETERMINE AVAILABLE LOAD CAPACITY. IT IS ASSUMED AT TIME OF PERMIT, PANEL 'L11' HAS SUFFICIENT CAPACITY FOR ADDED LOADS. ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL ENGINEER WITH METERED DATA PRIOR TO INSTALLATION OF ELECTRICAL SYSTEMS TO VERIFY SUFFICIENT CAPACITY IN PANEL. 2. FIRE ALARM SCOPE LIMITED TO REMODEL SCOPE ONLY. FIRE ALARM SYSTEM SHALL COMPLY WITH NATIONAL, STATE, AND LOCAL CODES. SYSTEM SHALL BE DESIGN/BUILD BY CONTRACTOR. FIRE ALARM DEVICES SHOWN ON PLAN ARE FOR DESIGN INTENT. FINAL DESIGN RESPONSIBILITY BY DESIGN/BUILD CONTRACTOR. NOTES: FLAG NOTES: 1 REUSE EXISTING TV RECEPTACLE CIRCUIT FROM EAST WALL OF BAR TO SERVE NEW TV LOCATION. REUSE EXISTING TV RECEPTACLE CIRCUIT FROM WEST WALL OF PRIVATE LOUNGE TO SERVE NEW TV LOCATION. REUSE EXISTING ELECTRICAL CIRCUIT FROM WEST WALL RECEPTACLES BEING REMOVED TO SERVE NEW FLOOR RECEPTACLES. PROVIDE HUBBELL S1R8PTFIT2 8" FIRE RATED POKE-THROUGH WITH (2) DUPLEX RECEPTACLES. COORDINATE EXACT REQUIREMENTS WITH LOW-VOLTAGE CONTRACTOR PRIOR TO ROUGH-IN. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. REFER TO ARCHITECTURAL DETAILS FOR FIRE PROOFING OF PENETRATION. REUSE EXISTING ELECTRICAL CIRCUIT FROM WEST WALL RECEPTACLES BEING REMOVED TO SERVE NEW TV RECEPTACLE. REUSE EXISTING RECEPTACLE CIRCUIT FROM PRIVATE LOUNGE TO SERVE NEW RECEPTACLE LOCATION. ROUTE 1" CONDUIT WITH PULL STRING FROM ELECTRICAL ROOM 110 TO THIS LOCATION FOR FUTURE USE. RELOCATE EXISTING FIRE ALARM DEVICE AT THE SOUTHEAST CORNER OF THE EXISTING FIREPLACE TO THIS LOCATION. RELOCATE THE EXISTING FIRE ALARM DEVICES AT THE SOUTHWEST CORNER OF THE EXISTING FIREPLACE TO THIS LOCATION. PROVIDE (2#12 & 1#12GRD) IN A 3/4"C FROM PANEL 'L11' LOCATED IN ELECTRICAL ROOM 110 TO THIS LOCATION. COORDINATE EXACT POWER REQUIREMENTS OF FIREPLACE WITH FIREPLACE SUBMITTAL PRIOR TO ROUGH-IN. RELOCATE EXISTING RECEPTACLES TO BELOW COUNTER. EXTEND EXISTING ELECTRICAL FEED TO NEW RECEPTACLE LOCATION. TV F F H H H H (E) (E) H (E) PANEL 'L12' H J FP (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) CO (E) PANEL 'L11' (E) DIMA-1 (E) DIMA-2 (E) DIMA-3 (E) DIMB-1 (E) DIMB-2 TV S TV J J (E)FP FP FP J SS TV 1 TV 2 2 3 3 3 4 4 5 5 H L11-2,4 L11-6 L11-28 L11-26 J J J J 6 6 6 6 6 F CO 7 8 7 8 H 9 9 9 L11-30 L11-32 10 10 DW H TV TVL11-34 11 11 (E) Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E2.1.DWG10.17.1810:09:43 AM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL ASI #1 10/12/2018 GAS LINE RFI 10/15/2018 ELECTRICAL ASI #2 10/17/2018 ELECTRICAL FIRST FLOOR PLAN - NEW BAS MAS E2.1 11/01/18 SCALE: 1 ELECTRICAL FIRST FLOOR PLAN - DEMO 1/8"= 1'-0" 1. SALVAGE EXISTING ELECTRICAL AND FIRE ALARM DEVICES FOR REUSE. REFER TO ELECTRICAL PLAN ON SHEET E2.1 FOR NEW LOCATIONS. 2. SALVAGE EXISTING ELECTRICAL CIRCUITS FOR REUSE. REFER TO ELECTRICAL PLAN ON SHEET E2.1 FOR LOCATIONS OF WHERE REUSED CIRCUITS SHALL BE USED. 3. WHERE EXISTING ELECTRICAL CIRCUITS ARE NOT BEING REUSED, REMOVE CIRCUIT IN ITS ENTIRETY TO PANEL. NOTES: F F CO F TV TV TV H C C C H H H H H C C C C H (E) PANEL 'L12' CO H (E) PANEL 'L11' (E) DIMA-1 (E) DIMA-2 (E) DIMA-3 (E) DIMB-1 (E) DIMB-2 J FLAG NOTES: 1 SALVAGE THE EXISTING CIRCUIT SERVING THIS RECEPTACLE FOR REUSE. REFER TO ELECTRICAL PLAN ON SHEET E2.1 FOR NEW RECEPTACLE LOCATION. SALVAGE EXISTING FIRE ALARM DEVICE FOR RELOCATION. REFER TO ELECTRICAL PLAN ON SHEET E2.1 FOR NEW DEVICE LOCATION. 1 1 1 1 11 1 2 2 2 2 TV Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E2.0.DWG10.17.1810:09:40 AM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL ASI #1 10/12/2018 GAS LINE RFI 10/15/2018 ELECTRICAL ASI #2 10/17/2018 ELECTRICAL FIRST FLOOR PLAN - DEMO BAS MAS E2.0 11/01/18