HomeMy WebLinkAboutGLEN LYON LOT 53 COLDSTREAM UNIT 15 LEGAL.pdfTOUTNOTVAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
OITINER
COMTRACTOR SRE BUILDERS, INC
PO Box 53 75
Vai1, Co
8l_658
License:703-b
APPLICANI SRE BUIIJDERS, INC
PO Box 6376
VaiI, Co
81558
License:703-b
Desciption:
INTERIOR REMODEL
DEPARTMENT OF COMMUMTY DEVELOPMENT
GL-".
s\.^r-*,--,^
c'o-nl d NOTE: THIS PERMIT MUST BE POSTED ON IOBSITE AT ALL TIMES
ADD/ALT MF BUILD PERMIT Permit #: BO2-0207
Job Address.: 1.476WESTHAVEN DR VAIL Status.....: ISSUED
Location......: 1476 WESTHAVEN COLD STREAMCONDO #15 Applied...: 07 /03/2002
Parcel No....: 210312108015 Issued...: 07/15/2002
Project No...: Expires...: 01./11./2003
FELDMAN, AARON
4445 EASTGATE I.TAIJIJ STE 4OO
SAN DTEGO CA
92L2t
License:
o7/03/2oo2 Phone:
o7/03/2002 Phone: 970-376-1536
O7 /03/2oo2 Phone: 97o-376-!536
Occupancy:
Type Construction:
Type Occupancy:
Valuation:
R-1
V 1-HR Type V 1-Hour
??
$80,000.00
Fireolace lnformation: Restricted: Y
Add Sq Ft:
# of Gas Appliances:
0
0 # of Gas [ogs:#of
Wrxrd Pellet: ***i FEE SUMMARY
Building-->
Plan Chetk-->
Investigation->
will call->
S64o. oo Reshrarant Plan Review->
$415-oo DRB Fe€---->
S0.00 RccreationFee-_------>
$3 . 00 Clean-uP DePosit---->
TOTAL FEE+_->
$0.00
$r-00.00
$0.00
$1, 159 .00
$1, 159 . 00
s0.00
$1, 1s9 . 00
s1, 159 . 00
$0.00
Total Calculated Fees->
Additional Fees-->
Total Pemrit Fce___>
Payments-..._--1
BALANCE DUE__>
Approvals:I€e'm: 05100 BUIL,DING DEPARTMENT
07/1-l/2OO2 GCD Action: AP
Item: 05400 PLANNING DEPARTMENT
ftem: 05600 FIRE DEPARTMENT
Item: 05500 PITBLIC WORKS
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an
accurate plot plary and state that all the information as required is correct. I agree to comply with the information and
plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoninp
and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable
thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPIIONE AT 479-2138 OR AT OUR OFFICE FROM 8:00 AM - 5
PM. \
Send Clean-up Deposit To: N/A
OWNER OR CONTRACTOR FOR HIMSELF AND OWNET
PAGE 2
Permit #:802-0207
CONDITIONS OF APPROVAL
as of 07-15-2002 Status: ISSUED
PermitType: ADD/ALTMFBUILDPERMIT Applied: 07/03/2002
Applicant SRE BUILDERS, INC Issued: 07 /15/2002 970-376-1536 To Expire: 07/11./2003
Job Address: 1476 VVESTHAVEN DR VAIL
Location: 1476WESTHAVEN COLD STREAMCONDO #15
Parcel No: 210312108015
Description:
INTERIOR REMODEL
Conditions:
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
Cond: 14
(BLDG.): ALL PENETRATIONS IN WALLS,CEILINGS,AND FLOORS TO
BE SEALED WITH AN APPROVED FIRE MATERIAL.
Cond: 15
(BLDG.): SMOKE DETECTORS ARE REQUIRED IN ALL BEDROOMS AND
EVERY STORY AS PER SEC.310.6.1 OF THE 1997 UBC.
Cond:1
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY
WORKCAN BE STARTED,
Cond: CON0005422
TYPE VONE HOUR CONSTRUCTION REQUIRED TO BE MAINTAINED
THROUGHOUT.
FRAMING DETAIL REQUIRED FOR WINDOWHEADER
PRIORTO INSPECTION.
**aaa+llt++*ar {rr*a* **+fl'} +a ** **rt +*+t+ ++ + a + raa ar**r ft *** * * * a* **+ t++f*** a* | **i I f** * * *** * a*l f*
TOWN OF VAIL, COLORADO Statement
+f*i't*t+++ +** * * * t* ** t++a*** ++ I +****+ ++ + +* *t *t*a***++a +** +*a*ta++l+ *** *****'i'+fl+** * at**l:++a**
Statement Nuniber ! R000002720 Amount: 51,159.00 07/L5/2O02L2:57 PiN!
Pa)ment Method: Check InLt: LrC
Notation: #1469/SRE
Builders
Permit No: BO2-O2O7 Type: ADD/AL,T MF BUILD PERIIIIT
Parcel No: 210312108015
Site Addres8 3 1476 V|ESTHAVEN DR VAfIJ
Location: 1476 I|ESTHA\rEN COLD STREiMCONDO #15
Total Feea: $1, X59.00
This Palment: $1,159.00 Total ALL, PmtE! $1,159.00
Balance: $0.00
*+ * * **** 'tt ** +f**+ ** r*** *+ta***** * ** * *rt********r***t a***** *++* +*t *+'l * ****l***r** a***+ +*+*r*r
ACCOIJNT ITEM LIST:
Account Code Descriotion Cunrent Pmts
BP OO1OOOO31111OO BUILDING PERMIT FEES
DR 00100003112200 DESIGN REVIEI^I FEES
PF OO1OOOO31123OO PLAN CHECK FEES
WC OO1OOOO31128OO WILL CALL INSPECTION FEE
640 .00
100 .00
416. 00
3.00
orr.r.orr4;.,.ltr,
Building Permit #:
TOVNqFVIL
75 S. Frontage Rd.
Vail, Colorado 81657
General Contractor:
s8(iV)trr 1r.'
ContactEld Phone Fs:
fo\3'll--l
COMPLETE VALUATIONS FOR BUILDING PERMIT (LabOT & MAICTiAIS
BUILDING: $ \o .ooo 6D ELECTRICAL: $ QL-$oo "00
./n
OTHER: $ fr :* pVa! 4p" tt. "-
PLUMBING: $ \A <:t>o .dt MECHANICAL: $l'orAl:$ Fifr.c6O
For Parcel # Contact Assessors Office at 97O-328-8640 or visit
(application Will not be 'ATd Lrl9, g Jf.", n u m ber)
lob Name: Gbl s'voa.n,.. e,5
etailed descriDtion of work:--
WorkClass: New( ) Addition( ) Remodel ffi Repair( ) Demo( ) Other( )
Does an EHU exist at this location: Yes ( ) No ( )Work Type: Interior ( ) Exterior ( ) Both X)
Type of Bldg.: Single-family ( ) Two-family ( ) Multi-familY,OQ Commercial ( ) Restaurant ( ) Other ( )
No. of Accommodation Units in this building:No. of Existing Dwelling Units in this building:
of Fireolaces Existinq: Gas Appliances ( ) Gas
Wood Burninq (NOT ALLOWED
Does a Fire Sprinkler System Exist: Yes ( ) No-$.Does a Fire Alarm Exist: Yes
r Fees:
Fees:
F:/everyone/forms/bldgperm
of Construction:
**************************************FOR OFFICE USE ONLY*****r<********************************
Y'\
-YA
I
tY* , E E*s"t
3'b"
Bo)*or^ {\ou. t'rn\d | 5
(o\0\ S\rQcuzrt
YY' l'
t f;{s oo13 d*<\r i-'9.<g1
€-t-tA Jg
.r.r',.'i.r)
J
)b
tlrl,.,-?,
F$;-lsi
''"tr!i
T s \&+
9 -t l
I.IJ
\,
M
s-.
o
c0
o,.)
*3 (r
I
to
.J
r,'t
U @ 3
tr-rr
L d L
+
V)
0 d
b
3
-n
E
3
-g
=
@
-t1
,t .;
.LJ
I
IXXX-X wrr$> to bQ (e'F'1ov<'\
t,, bp arld'zd
(J
{\Je^.)
(,i s'
,?{
I yl
d
CI
rS
f;l
lggi$
liiiru
EE
olt
FE
TE
TH
$f,
$t
!i
{r
EE
'E
R
l&J c5 ET lJ--l&e
(E
o
tr
=F
!k
x
\)(L r \\)o
a
?4
jii
4i
Pti
* egEH \.-'X-od t_:> R
[iEB qs E t o
s
.{
t/)1
A
)
-<
a
F
o)L
3.,OA
t
3-k
SJ \t-5 st :*S \!
V)
\)-5
e +
.T
I
I
I
I
I
I
"0.
G
\j
a./
I -"t-1
:
>R s:r,'i \._r:
.+
VI
\X 'r|l.
l:-
lrt
I -.r r \.;
ti q)4 ZT
tt
|:iF tt t4 l--l N t--t F{NH r)i r'l
f Aq
A--
'\)
.J o
F\-a
(\
\|
b^-.r c\-/
i-*l-
g \rj
-:
"\o\-o \Lta,''4\D '{ /'r-/
(
-ttn-
.V .(.i ':)
%.
1 )"'o{l
L)a !41y 1
6'rs'rj:
fwlo"-
d t:
Y1 l t'
{?xc $?
t,tFr IN I f-l IN r$
IL e
C-'?lrl
CF..B:
l&,.]L o
E
o c
=o l-
! ",ll o:
J]l -$ ill .: <rli
Pgil
....9 t'lll
b#-u .ii J UiI t rtii arli
e 5li tll E 'r-..v) 't! L
lle \3J IE
ffi ;il
it?
ll-(ii:
r li.'l e ttF dlt iil
;f ivl "lb
il'
-A iY:
"oil;uil !t
ti
ri ll
ll
ll
tl
!l
tl
ti
tl 'rl rI
tl ,il tl
ll
$q
q
' J/.
TA
a.
Fq;.,
:1
te
E$x F il,.ll*l.L
4*'.
/
\
)N 7 r I
g
:<O
LrJ al
ie
AY
arv. ^ii 7
,\
\,/ v;N
t--
C!
Fd:K.,oz'st / ,q,D{
ll tl
it),r
(ol
,t :l
=t
N
$r^-*
,/c.,t'"
N "tk -z\o,
\LU:
, i -tt
J A.I T-
/
V,'r\r
\-\
,//,//\//.\z
,fr.
rJ'-t"
Ei--fif qli;
F* L[--
.1,s"
{'
r
frr
;
j
/l /r'//////
//,/
7
)I
7
)
!
f
)
U
.\\
\..\
o-\.,
-Ua , 'r)_
7t
\
\o;\9?r.\
'\7
3t
v4r,
zz' tt 7/4" I v-' :- -:-:--- *
|
45;t.r.uv \
+-
C.
=--l
E
\
7q" ..,i
OPEN TO
BE DROOM
P#,
OPEN TO
LIVING ROOM
)-T IRD FL.OOR
-4
VAIL CASCADE
CONDOMINII.,IMS
odrfiF"'{fiw
June 24,2Q02
Town of Vail
Design Review Board
S. Frontage Rd
Vail, Colorado 81657
To Whom It lvlay Concern:
The Coldstrearrr Association approves the construction work that is being proposed by
Andrew Woll owner of Coldstream 15. That includes the addition of an exterior window
on the second level facing the west.
Don Maclachlan
General Manager u7
1476 Westhaven Drive . Vail, Colorado 81657
970.47 6.61 06. 800.543.4801 . Fax 970.47 6.4946
-d
VAIL CASCADE
CONDOMINIUMS
Jurre 24,2002
Town of Vail
Design Review Board
S. Frontage Rd
Vail, Colorado 81657
To Whom It May Concern:
The Coldstream Association approves the construction work that is being proposed by
Andrew Wolf, owner of Coldstream 15. That includes the addition of an exterior window
on the second level facing the west.
Don Maclachlan
General Manaser u7
t 476 Westhaven Drive 'Vail, Colorado 81657
970.476.6106. 800.543.4801' Fax 97O 47 6.4946
TOWN OF VAIL DEPARTMENT OF COMMTINITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 8t657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ELECTRICAL PERMIT Permit #: E02-0140 'Y,oA-o7,01
Job Address: 1476 WESTHAVEN DR VAIL
Location.....: Unit l5 kitchen area
Parcel No...: 2103 12108015
Projecr No : ?rdfcl. . 01\ G
OI^INER FEI-,DMAN, AARON
4445 EASTGATE MALL STE 4OO
SAN DIEGO CA
9212r
L i cense ;
CO}fTRACTOR NATIVE EI-,ECTRIC
P.O. BOX l-807
EAGIJE, CO
81631
Lrj-cense: 143-E
APPI-,ICANT NATIVE EIJECTRIC
Status...: ISSUED
Applied. . : 07125/2002
lssued. . : 08/1312002
Expires . .: 02109/2003
o7 /25/2002 Phone:
07 /25/2002 Phone: 970-328-L293
07/25/2002 Phonez 970-328-1293
P.O. BOX 1807
EAGLE, CO
81631
License:143-E
Desciption: REMODEL OF OLD WIRE
Valuation: $4.500.00
* +** + * t *:trt l
'N.
t i l * +
Electrical-----> $90.00 Total Calculated Fces--> $93.00
DRB Fee-----> $0.00 Additional Fees---------> 50.00
Invcstigation--> $0.00 Total Permit Fee----> S93 .00
Will Call-----> $3 .00 Palments--------------> S93 .00
]OIA|.FEFIS-> S93.oo BAI-ANCE DUE-----> $0.00
* * *,*,t* a * * * * * | * * * *
Approvals:Item: 06000 ELECTRICAL DEPARTMEI{TT
07/25/2002 DF Action: AP
Item: 05600 FIRE DEPARTMENT
CONDITIONS OF APPROVAL
Cond:12
(BLDG.): FIELD TNSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
r * * *:r* a++ t + + + t + 'r r
DECT,ARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, Unifbrm tsuilding Code and other ordinances of the Town applicable thcreto.
REQUESTS I:OR INSPECTION SHALL BE MADE TWENTY.FOUR HOURS IN ADVANCE BY
SIGNATURE O
OFFICE FROM E:00 AM - 5 PM.
FOR HIMSELF AND OWNEF
+a+a**+t++++'i*a+**'il+a+*a**lt+*a'it}ll'**l+lr**+*t+l*l'ta*+ll**a'*'ltl+al * ** *t t**** *** + + +* * + t 'i * + + *
TOWNOFVAIL, COLORADO Statem€nt *+******'t**f*+**t+*la*****tf++*+'|at*t'*t+*aa***t+t*f*r*+faatf{r+ttaaf****ffa***a*++at*t'}*t+**+
Statement Nurnber: R000002869 Amount: $93.00 08/13/200203:23 PM
Payment Method: Check fnit: DDG
Notation: Native Elec.
3t47
Permit No: 802-0140 Tn)e: ELBqTRfCAL PERMIT
ParceL No3 210312108015
Site Addre6a: 1476 WESTHAVEN DR VArL
Locatlon: unlt 15 kLtchen area
Total Fees: $93.00
ThiE Pa)ment: S93.00 Total ALIJ PrntE: $93.00
BaLance: $0.00 **t{rlt*f**rl it*+t******'}l*+**'}**l+*i*t**t+a!**+**tf***a**'ta+***'}*+a**t'}++++**,t**tt**+a*+++ia*t
ACCOI.JNTITEM LIST:
.Account Code DescriDtion Current Pmts
EP OO1OOOO31114OO TEMPOMRY POI{ER PERMITS
IilC OO1OOOO31128OO WILL CALL INSPECTION FEE
90 .00
3.00
APPUCATION IF INCOMPLETE OR UN
Project #:wy6apJ/k
Building Permit #:
Electrical Permit #:
97 0-479-2A49 (Inspections)
NWI{OFVJ
75 S. Frontage Rd.
Vail, Colorado 8
EleEtrical Contractor:
AlArrve EuEc-,zi L TAlc,
Town of Vail Reg. No.;
€- t+3 Contgct and Phone #'s: Jo( Jie - t 71. 3 uf,17O - 7o+7507 c€L{_
Contractor Signature: -1/ , / n
. ftA,^, L /' . ,*Ltn
CoMPLETE SQ. FEET FOR NEw BUIIDS and VALUATIONS FOR ALL OT}|ERS (Labor & Materiats)
AMOUNT OF SQ FT IN STRUCTURE:ELECTRICAL VALUATION : $
Contact
************************
County Asgessors Off ice at 970-329-864O or visit for Parcel #
Parcel * lnequirea
Job Name: S RE Brr reoezs J,{c Job Address: ,9o:? 5-'a€4*^ t-a4Pr + 11 l't /k Wes-, t+Avel.JD a.
LegalDescription ll Lot: ll alock: ll riting:Subdivision:
Owners Name:Address: !1 Te.yleszuav'^ Dn, ll ntrone:
Engineer:Address:Phone:
Detaifed description of work: j)
-
t<eyvrtarc,u
workclass: New( ) Addition( ) Remodel gqr Repair( ) Temppower( ) other( )
Work Type: Interior ftf Exterior ( ) Both ( )Does an EHU exist at this location: Yes ( ) No rc
Type of Bldg.: singlefamily ( ) Duplex ( ) Mutti-famity p{ commercial ( ) Restaurant ( ) other ( )
No. of Existing Dwelling Units in this. building:No. of Accommodation Units in this building:
Is this permit for a hot tub: yes ( ) trlo F^<t
Does a Fire Alarm Exist:
***************FOR OFFICE USE ONLY***ffiwes--r
Other Fees:Date Received:a---.:. ,1-;'n
DRB Fees:Acceoted Bv:
Planner Sign-off:
***********
,.)* 4"
.^+ks
F:/everyone/forms/elecperm
TOWN OF VAIL DEPARTMENT OF COMMLINITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 816s7
970-479-2t38
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MECHANICAL PERMIT Permit #: M02-0152
Job Address: 1476 WESTHAVEN DR VAIL Status . . . : ISSUED
Location.....: Unit 15 kitchen area Applied . . : 07/18/2002
Parcel No...: 210312108015 lssued. . : 07/2312002
ProjectNo , pt667 - OZ( e Expires. .: ot/tg/2003
owNER FELDMAN, AARON 01 /r8/2O02 phone:
4445 EASTGATE MAT.,L STE 4OO
SAN DIEGO CA
92L2L
License:
CONTRACTOR COITORADO WEST PITUMBfNG & HEA0T/le/2002 Phone: 3O3-926-4353
P.O. BOX 1
wor,coTT, co
815 55
License : 2!8-P
APPLICAIIT COLORADO WEST PLIIMBING & HEAo7/78/2002 Phone: 303-925-4353
P.O. BOX 1
WOIJCOTT, CO
81555
License : 218-P
Desciption: SUPPLY NAT GAS TO 2 FPS I RANGE AND I WATER HEATER
Valuation: $925.00
Fireplace Informalion: Restricted: Y # ofcas Appliances: 0 # ofoas Logs: 0 # of Wood Pellet: 0
t* *:l*'* a a 't
it t t:t *,t *** tt**t,t:t*tt,tl t+**
Mechanical---> S20.OO Restuarant Plan Review---' $0.00 Total Calculated Fees--> $2S.00
Plan Chcck--> 55 . oo DRB Fcc------------> S0 . 00 Additional lees'----> S0 - 00
Investigation-> S0 . oo TO'l AL FEES-------> $28 - 00 Total Permit Fee------> 928 - 00
WillCall----> 53 . oo Payments--------------> S28 - 00
BALANCE DUE-----> SO, OO
{ l l * l 'l * + + + l +'} ++ a l Item: 05100 BUII-,DING DEPARTMEI0T
o7/23/2oo2 df Actj.on: AP
07/23/2002 JRJM Action: AP
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond:12
(BLDG.): FIEI-,D INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPI-,IANCE.
Cond: 22
(BLDG.): COMBUSTIONAIR IS REQUIRED PER SEC. 701 OF THE 1-997 IIMC, OR SECTION
701 0F THE 1997 rMC.
Cond: 23
(BLDG. ) : INSTALLATION MUST CONFORM TO MANUFACTIIRES INSTRUCTIONS AND TO CIIAPTER
10 OF THE L997 UTTC, CHAPTER 10 OF THE 1997 TMC.
Cond: 25
(BIJDG.): GAS APPITIAIICES SHAI-,L BE VBNTED ACCORDING TO CIIAPTER 8 AIID SHALL
TERMINATE AS SPECIFIED IN SEC.8O5 OF THE 1997 I'MC, OR CHAPTER 8 OF IrHE 1997 IMC.
Conds 29
(BI,DG.): ACCESS TO HEATTNG EQUIPMENT MUST COMPI,Y WTTH CHAPTER 3 AIiID SEC.IOl7 OF
THE 1997 T]MC A}ID EIIAPTER 3 OF THE 1997 IMC.
Cond: 31
(BLDG.): BOfLERS SHALI-, BE MOUMfED ON FLOORS OF NONCOMBUSTIBLE CONST. IJNLESS
IJISTED FOR MOUNTING ON COMBUSTIBI-'E FIJOORING.
Cond: 32
(BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECIANICAJ., ROOM PRIOR
TO AN TNSPECTION REQT'EST.
Cond: 30
(BI-,DG.): DRAINAGE OF MECHANICAIJ ROOMS CONIAINING HEATING OR HOT-WATER SUPPLY
BOIIJERS SIIAI.'L BE EQUIPPED WITH A FLOOR DRAIN PER SEC. LO22 OF THE L997 UMC, OR
SECTION 1004.5 0F Tr{E 1997 rMC.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is conect. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, Uniform Building Code and other ordinances ofthe Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE A 479-2118 OR AT OUR OFFICE FROM 8:00 AM - 5 PM.
CONTRACTOR FOR HIMSELF AND OWNET
****** + **** {.:f ***** ****** ++***i*****++*****++*****'}*+t** * * * *** ** * * ** ** i* + + * ** *l+ f, ** * * * * +* t * **
TOWN OF VAIL, COLORADO Statement *****+l f**t*t*+***+* * **t** ****'*++** * * *** ***+t* ****a+*** * ****ti* * * * * i * * * * * *
'3
* * * * * * * r *** * ** * * *
Stat.emerrt Number: R000002?81 Amount: $28.00 O7/23/2OO2L2:49 Pt4
Payment Method: Cash Init: LC
Notation: cash from Colo
West P &H
Site Address: l-475 hIESTIIAVEN DR VAII,
Location: Unit 15 kitchen area
This Payment:$28.00
Permi-t No: M02 - 0 L52
Parcel No: 210312108 015
T)t)e: MECHANICAL PERMIT
TotaL Fees:
Total AIJIJ PmTs :
$28.00
$28.00
Balance: $0.00 a********* +******* *+****** *******++ **+ +**t+*****t ** +*'i* *******+ ***t*++* * * ** I * * * * ** *t + +* * * * * *
ACCOI.JNT ITEM LIST:
Account Code DescriDtion Cunnent Pmts
I4P OO1OOOO31113OO I'IECHANICAL PERM]T FEES 2O.OO
PF OO1OOOO31123OO PLAN CHECK FEES 5.OO
I,IC OO1OOOO31128OO I,']ILL CALL INSPECTION FEE 3.OO
97 O - 47 9 -2149 (Inspections)
mrf0FVtn
75 S. Frontage Rd.
Vail, Colorado 81657
Cut/Spec Sheets
Permit will not be accepted without the following:
CONTRACTOR INFORMATTON
Contact and Phone #'s:
4-1r +t38 '/Aa 135 3
Mechanical Contractor:
(,0\c0*Dc wt;1 P+r+ tpe
qJ 5!L
(Required if no bldg. permit # is provided a
JobAddress: /S CoL> Sil2e/+"4,C.r b STI?I l+-r
t"tt'{35o keYSre-€ nuE- ui)I lt ve;1 n I x,i
S,JefLY uhr Q45 l)0r've /\a (\ )u-"aee lkk\-(L /.at/Jl
WorkClass: New( ) Addition( ) Alteration$() Repair( ) Other( )
Does an EHU exist at this location: Yes ( ) No ( )BoilerLocation: Interior( ) Exterior( ) Other( )
Type of Bldg: Single-family ( ) Duplex ( ) Multi-family p( ) Commercial ( ) Restaurant ( ) Other ( )
No. of Accommodation Units in this building: 4 No. of Existing Dwelling Units in this building: 3
: Gas Aooliances ft() Gas Wood Burnino (X) &
Noffype of Fireplaces Proposed: Gas Appliances ( ) Gas Logs M) Wood/Pellet ( ) Wood Burning (NOT ALLOWED
ffirningfirep|acetoanEPAPhaseIIdevice?Yesfi)No()
PLETE V TION FOR MECHANICAL PERMIT Labor & Materials
Assessots Office at 970-328-8540 or visit for Parcel #
* * :F * * * * * * * * * * * * * * * * * * * * * FOR OFFICE USE ON LYr * * * * * * * * * * * * *
F: /everyone/forms/ meciperm
********+**
8&f
*€*1 **##t'1
#
9
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S.FRONTAGEROAD
VAIL, CO 816s7
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MECHANICAL PERMIT PErMit #: MO2-0I66
Job Address: 1476 WESTHAVEN DR VAIL Status . . . : ISSUED
Location.....: Unit 15 Applied. . : 08/0912002
Parcel No...: 210312108015 Issued . . : 0811512002
ProjectNo : Expires. .: 0211112003
OUINER FEITDMAN, AARON 08/09/2002 Phone:
4445 EASTGATE MATJIJ STE 4OO
SAN DIEGO CA
92721
I-,icense:
coNrRAcToR HEARTH EXCHANGE, rNC. (THE) 08/09/2002 phone: 970-827-9623
P.O BOX 570
MINTURN, CO
81545
I-,icense: ]-74-M
APPLICANT HEARTH EXCHANGE, INc. (THE) o8/o9/2oo2 Phone: 970-827-9623
P.O BOX 670
MIMTURN, CO
81545
License:.174-YI
Desciption: CONVERSION/INSTALLATION OF 2 DIRECT VENTS FOR GAS FIREPLACES
Valuation: $5,000.00
Fireplace lnformation: Rest cted: y # ofGas Appliances: 0 # ofGas t.ogs: 0 # of wood Pellet; 0
* * ** *:tt*t|:|*t:t:i *,t t
Mechanical---> $100 . oo Restuarant Plan Revicw-> $0. 00 Totsl Calculated Fe€s--> $128 . 00
Plan Check_> S2S . 0O DRB Fee-> S0. 00 Additional Fees--> S0 . 00
Investigation-> S0 . 00 TOTAI- FEES-------> $12e - 00 Total Permit Fee-----> $128 . 00
Will Call---> $3 - 00 Payments----------; S129.00
BALANCE DUE----> $o . oo
IIEM: O51.OO BUILDING DEPARTMENT
o8/L4/2oo2 ccD Action: AP
IIeM' 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPI-,rANCE.
Cond: 23
(BLDG. ) : INSTALI-,ATION MUST coNFoRM TO MANUFACTIIRES INSTRUCTIONS Al{D TO CHAPTER
].0 OF THE 1997 I'MC, CIIAPTER 10 OF THE 1997 IMC.
Cond: 25
(BI-,DG.): GAS APPIJIANCES SIIAI-,L BE VE}flTED ACCORDING TO CHAPTER 8 AID SHAI-,L
TERMINATE AS SPECIFIED IN SEC.8O6 OF THE 1997 IJI{C, OR CIAPTER 8 OF THE 1997 TMC.
Cond: 29
(BLDG.): ACCESS TO I{EATING EQUIPMENT MUST COMPI,Y WITH CI{APTER 3 A}ID SEC.1O]-7 OF
THE L997 I'MC AND CIIAPTER 3 OF THE 1997 IMC.
** 'l'l*ataaat*,t't:i i t:|,* * ttti't t at *ttti +t tl ***t*t*aaat attt tttt:l * *ttl taa'ttt
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, Uniform Building Code and other ordinances ofthe Town applicable thereto.
RLQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE B AT 479-2138 OR AT OUR OFFICE FROM 8:00 AM - 5 PM.
OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
s/y'a
-o)t
Buifding Permit #| nA - oP7
Mechanical Permit #:
mwvWUilL
75 S. Frontage Rd.
Vail, Colorado 81652 Permit will not be accepterl without Ure fottowinE
Room
Air
o EqulpmentCut/Spe€
RECEIVED
AUG
TOV
coNTRAqTOR TMORMATTON Mechanicateon[EE?-
=
tbo .€- L- .,-
Town ofVail Reg. No.:
17/--zl
Conbct and phone #,, .Far ?2v a€97/ g9z-"e22 -EE"--5.r=qr_:]onrfuft
Atl-rr -- A
FrE:
\/
;lfrfr ?frl -
EAFE-€HI,
BATE ROUTTD,S W TLUATION FOR M ll & Materials)
--r-usffir
---tn firrParel #
-
t**"* C.l /r*-r- * g I:
ll Job Addn ICC '
:::::r i:::=!
L"g"th.riph* ll L"r ll eock: ll ririns,Subdivision:
Address: 5 7 9a teyfu-7E:--.7.-//.c-,^ * tllt 2z gZP Phone:
Engineer:Address:Phone:
DeTlifed description "f a/ 2 - 2,-.ea* tlenl eoi ./,,.<t4,..
WorkClass: New( ) Addition( ) AlterationX) Repair( ) Otfrer( )
BoilerLocation: Interior( ) ert*lor' 1 1 6lhurl )l
-_
ll -.!
Does an EHU exist at this location: v:::
Typeof Bldgl Singte-family( ) Dupto(( ) Mutti-family( ) Cor nmercial ( ) Rc
-n
staurant ( ) Other ( )
rro. or Exlsnng Dwelling UniB in this bulldlng:
-_
No. of Accommodation UniE in this buildinq:
+{qgilrelacg rlrrvpe of Fireplaces Proposeo: cas npptlances (.? ) cas roda-t w"ilF;Gt ( ) wood Burning 1i,r-, ,.rr_LCWED)
****** *********,:::::1111 FOR OFEICE USE ON LY* *'r' * ** * :f, :t,t:r* * * * * *
RECEIVE
**)91q5**i
Fl / evayone/fonnr/nrccfrpcnn
o
,
t,
-J,f{-
-
/"'" /*z
I(czvHEAr
INSTALLATION & OPERATING MANUAL
#942 DIRECTVENT
INSTALLATION & OPERATING MANUAL
DESIGN.CERTIFIED TO:
DECORATIVE &WALL FURNACE ANSI PERFORMANCE & SAFETY SIA'VDARDS
ail
D
Y
fTrt
GOP
U.S. PAIEIVIS:
*5.931.151,
#5,967,139
*6,N4,193
Wamock Hersey rlt f:=6r US
MPARTATTI:
READ'I'STRUC7IO'I'S CAREFIIIIY BEFORE
,NSf ALLANON. FNLURE TO'NSTAll TII'S
HREPL,.CE CORRECIL Y CA'V CTUSE SER'OUS
STRUCruP.,.L A/IID HRE HAZARDS AND
,IAY VOID YOUR WARRANTY.
GLOBAL POSII0NING: N43. 40.1T1' W 095 " 10.662'o July 2000
INDEX t
DESCRIPTION PAGE
SafetyRequiremenb/Specifications ........'l-2
VentingGuidelines/Clearances ......3
PositioningTheUnit .........4
RoughJnchimneyDimensions ....... 5
Rough-ln Dimensions . . ...... 5
RemovetheGlassAssembly..... .....,..... 6
DireclVentSystem Installation ..... 6-13
Guidelines & Requlrements for Dun-Vent GS & #800 Series Vent Systems . . . . . 6-9
HorizontalTermination with #800 Sedes D.V. Kit . ...10-12
Veilical Termination with #800 Sedes D.V. Kit .. . . ..12-13
Fan Installation (Optional) .. . , . ... l&15
Gas Line Installation Requirements - ilinimum/ltlaximum Pressures . . . . . ,.. 16-17
MillivoltBoardRemoval/lnstallation ......18-19
Log fnstallation ... .. ....... 20
Thermostat-RemoteConhol-WallSwitchlnstallation .......21
Gompleting the Installation (Replace the Glass Assembly, Upper & Lower Grills) . . . . . 22
DampercontrolOperation ..........23
.:
Lighting & Shutdown Procedures . .2+25
Manifold(outgoing)&lnlet(incoming)PressureCheckProcedures... ........26
MaintenanceRequirements .........27
Troubleshooting .... ..... 28-29
ReplacementParts. ......-. 30
INSTALLATION & OPERATING INSTRUCTIONS
IMPORTANT:
READ THIS MANUAL BEFORE INSTALLING AND USING THIS FIREPLACE
MODEL #942 DIRECT VENT
DECORAT'VE / ROOM HEATER GAS BURNING FIREPLACE
This ffreplace has been tested to and complies with ANSIZ1.88OCSA 2.33-M98 "VEilTED GAS FIREPLACE
HEATERS". Installation must comform with local building codes or in the absence of local building codes, with
the National Fuel Gas Code, ANSI 23.1, NFPA 54 - Gunent Edition.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not
prohibited by local codes. This appliance is only for use with the gpe(s) of gas indicated on the rating plate.
This appliance is not convertible for use with other qases, unless a certified kit is used.
FORYOUR SAFETY
WARNING: Do not use this fireplace if any part has been under water. lmmediately call a qualified service
technician to inspect this appliance and to replace any part of the control system and any gas control which
has been under water.
INSTALLATION AND SERVIGE MUST BE PERFORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.
WARNING: lf the information in this manual is not followed exactly, a fire or explosion may
result causinq oropertv damaqe. oersonal iniurv or loss of life.
WHAT TO DO IF YOU SMELL GAS
t Open windovvs.
t Extinguish any open flame.
I Do not try to light any appliance.
I Do not touch any electrical switch; do not use any phone in your building.
t lmmediately call you gas supplier from a neighbo/s phone. Follow the gas supplieCs
instuctions.
t lf you cannot reach your gas supplier, call the fire department
I Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
other
Page 1
WARNING: DO NOT REPTACE THIS BURNER UillT WITH AllY OTHER SIZED BURNER. REPLAGEMENT
WITH AN UNAUTHORIZED BURNER CAN RESULT IN TEMPERATURES EXCEEDING THE LIMITS FOR THIS
UNIT, AND VOID YOUR WARRANTY.
IMPORTANT:
NON.COMBUSTIBLE FACING IIATERIAL iIAY BE APPLIED OVER THE FACE. TO PREVENT THE
FACING ]IIATERNL FROII CRACKING AND FALLII{G OFF DUE TO EXPANSION OF THE FACE WHEN
HEATED. DO NOT ATTACH FACING MATERIAL DIRECTLY TO THE FACE OF THE UNIT.
UNIT SPECIFICATIONS.
HEIGHT IOP OF FACE): 40'
HEIGHT 00P OF STAND-oFF): 40'
FRONT WIDTH: 41718'
BACKWIDTH: 31'
DEPTH (INCLUDES FACE): 19'
FLUE SIZE: 5'exhaust. 8'intake
'0
Page2
VENTING GUIDELINES
IMPORTANT: THIS UNITISAPPROVED FORUSEONLYWITH ONEOFTHE FOLLOWING DIRECT VENT
SYSTEMS. THESE SYSTEMS MAY BE USED FOR HORIZONTAL OR VERTICAL
TERMINATIONS.
- SIMPSON DURA-VENT DV-GS DIRECT VENT CHIMNEY SYSTEM . 5" X 8'
Refer to pages #7-12 for complete venting installation inslructions / requirements.
-ffi44
- #845
- #846
CLEAMNCES:
Minimum clearance to combustible material:
From unib sides & back 0'
From unit top standoft 0'Toflooring: 0'
From #800 Sedes flexiblechimney: 2'
DIRECT VENT TERMINATION KIT - for terminations of 6' or less.
DIRECT VENT TERMINATION KIT - for terminations greater than 6' but less than 8'.
DIRECT VENT EXTENSION KIT{'
From heat outlet to 8'mantel (or see fu.1): 13'
From unit glazing (glass) to adjacent sidewall: 12"
From unit to endosure ceiling: 4'
From Dura-Venl chimney system: 1'
NOTE: Even though the minimum clearance from the sides and back is 0', we recommend that you allow an expansion
space of 1/4' ftom the sides and back. lf this expansion space is not lefi, the unit will make a loud 'banging' noise when
it heats up or cools down and cracking of any face material used may occur.
Figure 1
o_C F
E -*-
F
I
il I
tr t/ 4'
l0 3/8'
GRILL IPINING
Page 3
POSITION THE UNIT - figure 2.
1. Determine the exact position of your fireplace. lf possible place the flreplace in such a manner
that the piping will be placed between two studs so additional framing is not necessary.
2. The unit may be installed on either the outside or inside of an exterior wall. See figure 2.
GAUTION: THE SURROUT{DING WOOD CHASE 0F THE OUTSIDE WALL MUST BE
INSUI-ATED TO PRB/EilT COLD AIR FROIII ENTERING THE ROOM.
NOTE: Due to high tempentures, this unit should be located out of trafftc areas and awav from fumiture and
Ensure the proper clearances are followed as outlined on page 3.
MODEL#942 DIRECTVENT
NOTE: *
= 1/4'CLEAMNCE
1E" MINlMUM
Page 4
t. Frame an opening forthe firestop.
Refer to the information below.
TYPICAL HORIZONTAL INSTALLATIONS:
The location of this opening is determined by your venting specifications.
Dimensions are 121f2'wtdex 12 1/2' high when using the#800
series direct vent kits and 1 1 " X 1 1" when using the Dura-Vent
chimney system. The top of this opening must be a minimum of
45" ' above the height of the hearth (optional). See Fig. 3. Refer
topages foradditionalspecifications.
*IMPORTANT: This measurement is determined by the vertical
height and horizontal length of the venting application desired.
The measurement is to the TOP of the pipe. Refer to pages
#7 - #13 of this installation manual for requirements and
restric{ions.
.,._x r it HIIGHT
6. Rough in the wall enclosure. The minimum rough opening dimensions are 42112' wide,40 1/4' high and
21" deep. Euild the heafth to the desired size and height. See Figure 4.
NOTE:When the unit is installed directlyon carpeting, tile, orothercombustible materials otherthanwood flooring, itmustbeinstalled
on a metal or wood panel extending the full width and depth of the unit. Ihe minimum for the supprt platform under the unit is 42'
wide by 19'deep. lf masonry is to be used, (optional), prepare he necessary foundation for $e masonry load. Mren masonry
construction is being used, a lintel must be used over the top of he unit to support the added weight.
NOTE: A hearth is not requircd. lf a hearth is desired, combustible materials may be used.
NOTE: Provide for a minimum of 6' of clearance in fiont of the lower grill. This will provide adequate space for opening to
operate the control valve. Do not obstruct the upper and lower grill areas to allow proper ventilation air around the unit. Air
enters the unit at the lower grill and exits at the upper grill. Do not block this passage.
FIGURE 4
DTSIRID
HTARIH
4? 1/ ?'!
DESIRED HEARTH HEIGHT
Page 5
B)
1.
PREPARE THE UNIT.
REiIOVE THE GLASS ASSEMBLY. See fig. 5.
A. Locate the spring-loaded handles securing the
glass assembly (under the firebox).
B. Pullthe latch handles out, then down to release
the glass assembly.
C. Pull the bottom of the glass assembly out and
lift up off the tabs at the top.
D. Set aside where it will not be broken.
E. Remove the log package and klinkers from
inside the firebox & set aside for later installation.
FIGURE 5
c) |NSTALL THE DTRECT VENT Krr.
VENTING REQUIREMENTS
IMPORTANT: THIS UNIT IS APPROVED FOR
USE ONLY WITH ONE OF THE FOLLOWNG
DIRECT VENT SYSTEMS.
Note: We recommend using the #800 series direct
vent system for horizontal vent runs only. The
Simpson Dura-Vent DV-GS 5" x 8" system may be
used for both horizontal and vertical vent runs.
-W DIRECT VENT TERMINATION KIT - forvent
runs 6'or less.
- #845 DIRECT VENT TERMINATION KIT - for vent
runs greater than 6' but less than 8',
. #846 DIRECT VENT EKTENSION K]T. 6'
. SIMPSON DURA.VENT DV.GS DIRECT VENT
GHIMNEY SYSTEM - 5" x 8".
See figure 7.
HORIZONTAL TERMINATIONS:
Minimum 6' run directly from appliance outlet, followed by
a 4Sdegree elbow
Minimum horizontal run outlet: 6'
Maximum Horizontal run: 20 ft. (with 1/4' per foot incline)
VERTICAL TERMINATIONS:
Attach a 4Sdegree elbow dhec{y onto appliance outlet.
Maximum vertical rise from appliance ouUel 40 ft.
IIIPORTANT: Straight vertical terminations must use
the included restrictor plate for vent runs 15'- 40'.
ELBOWS:
(1) 45" elbow at start & (2) 90" elbows included within the
maximum vent runs. Each additional elbow reduces the
maximum horizontal distance by 5'.
FOR SIMPSON DUM.VENT DV.GS 5" X 8'CHIMNEY
SYSTEM INSTALLATIONS - Follow chimney installation
insbuclions included wih he chimney system.
HANDLES
Page 6
Vedical Temindion: A tlfuegree
dbow may be athched dlrectly to
fte lireplace and run a maximum of
rO ft. 2.g!.degree elbows may be
used within the 'o ft. vertical vent run.
Vent runs of 1$ - rO'must installfte
r€stlictor plate included with lhis
Itreplace.
20FI.X X. HORtrO|{TAL RUil
I[IPORTAI{T:
I'4' RISE PER HOREOIITAI
FOOT ruST BE ilAIIITAIIIED.
Horizontal terminations: The minimum vent run dirccdy off the fireplace is 6', Connecl to a 'f$degree elbow pdor to attaching to the fireplace to ensuro tne chlmnsy is pocitioned
hodztontally. 2 . qldegree elbows may be used wihln the marimum 20 ft. horizontal vent run.
For each additional elboq the maximum horizontal distance must be rcducsd by t.
WHEN VERTICALLY TERIIINATING THE I,IINIMUM CHIMNEY HEIGHT ABOVE THE ROOFLINE IS DETER]I'IINED
BYTHE FOLLOWNG G}IART:
Roof Pitch
Flat to 6112
il12to7t12
fl12toU12
U12togl12
9112101U12
1U121o11n2
Minimum Heiqht
above roof line
Itt
1ft.3In.
lfL6in.
2fr
2ft6in.
3ft3in.
Roof Pitch
11112to12112
fl1zto1U12
1qfl'ofit12
16112to1U/,2
1U12|omnz
20112to21112
ilinimum Heiqht
above roof llne
4ft.
5fl
6 fr"
7ft.
7ft.6in.
8ft
ITPORTANT: \,ERTICAL TERMII{AIIO}IS USING I}lE #800 SERIES FLEXIBLE CHhINEY SYSfEilS REQUIRE A SUPPORTII'IG
CHASE TO BE BUILT AROUI{D THE CHIIINEY ABOVE THE ROOF Ut{E. A 2'CTEARAIICE TO COIIBUSNBLE IIATERIALS MUST BE
TAI{TAIIIED AROUI{D T}IE PIPE.
Page 7
TMPORTANT: VENT TERiIINATION MUST NOT BE LOCATED WHERE lT WLL BECOME PLUGGED BY
SI,IOW OR OTI{ER MATERIATS.
Follow Figure 6 for clearances
to doors, windows and
ground level.
D = UNVEN1ID SDFFI I 3 = VENTED SoFFIT
A. la'(30cn)
B. a4'(60cn)
c.84'(e.lM)
D. l2- (30cn)
_J. L.l^l -l4*
.fN_'s I *' tLl , n=
D)Aa B -.,filtE^
A,trt t I
^l-r
r^
5+
Page 8
Figun 7A
WPICAL HORIZONTAL TERMINATION
EXAMPLE OF TYPICAL HOR'ZONTAL & VERTICAL TERMINATIONS
40 FEIT T4AX
llob: Sinpcon Dur&vent
chimney sptem shown In
vortlcal tormlnation.
-i,ilrrr*rt
HE I GHT
SEE CHART
DURA-VENT CHIMNEY I' I4INIMUM CLEARANCE
TO COI,IBUSTIBLES
ROOF PITCH MINIMUM
HEIGHI (FEET)
.LAT TO 6/12
s/1? 10 7 /12 t.e5
7 /t? rE B/t?1.5
/L? IE 9/r2 2
9/t? rE to/t?4.5
t0/t2 IE |/r2
1/t? fD t2/12 4
t?/t? ro L4/t2 5
4/17 \n G/12
,/t? ra tg/l
a/1? IE ?0/t?
?0/t? rtr ?l/12 8
MlN.45'
OF FRAI,IE
ild: Kosy H.!t Dire€t Vent $pbm
slpwn in horLont l tennination.
TO TEP
OPENING
FIRESTOP
Figuo 78
Page 9
*SIMPSON DURA.VENT DV.GS CHIMNEY SYSTEM INSTALLATIONS:
Follow the installation instructions included with
the chimney system along with the following
requirements:
- Vent runs must be in compliance as outlined on pages
#6 - #9 of this installatlon manual. Sbaight vertical runs
of 15 .40 ft. require a restrictor plate.
- A 45 degree elbow may be used direc{ly at the stove
connection to vertically position the chimney.
DURA_VENT 8'X 5'
45'ELBOV
- The 5" pipe on the elbow or 6" section fits tltlSlDEthe 5" collar on the stove.
- The 8" pipe on the elbow or 6" sec'tion fits OUISIDE the E" collar on the stove. FIOURE I
Secure the elbow or 6" sec'tion of chimney to the 8" collar with four screws (not provided).
TNSTALLATTON OF #800 SERTES DTRECT VENT TERMTNATIoN K|T(S)
ITPORTAilI:
The flax pipe is permrnently attached to tho extsrior plate. 00 NoT ATTACH tho *844 or #84i termination kit to the stove (or
extenrion kit) until it has passed through the wall or roof. Tho tormination plateo should all be installed on the exterior of the outsidE
wall or too of chase on the rcof.
lF TERIUI|i{ATING AGAINST VINYL SlDll{G, A Vll{YL SIDING PROTECIOR, INCLUDED WTH THE #844 and
#845 DIRECT VENT K]TS, MUST BE USED. FOLLOW INSTRUCTIONS IT{CLUDED.
CAUTION: This sas appliance must not be connected to a chimnev flue selinq another tvDe of
1. lf your chimney termination is 8' or less ftom the stove top and doesn't require an extension kit, proceed
to step #6.
2. lf your chimney termination will require one or more extension kits (pail fE46), proceed with the following
steps. Each #846 extension kit contains enough 5" and 8" flexible aluminum to extend the chimney an
additional6'.
3. Gently sfretch the 5" & 8' flexible aluminum pipes on the termination kit (#844 or #845) and on each
extension kit, if used, the length required so when all the sections are connected together, the chimney
height for your installation is attained.
IIIIPORTANT: DO NOT STREICH THE EXTENSION KIT BEYOND 6'. DO NOT STREICH BEYOND WHAT lS
REQUIRED. IT IS VERY DIFFICULT TO RECOMPRESS THE FLEX PIPES ONCE STREICHED.
Page 10
o
4. Using your extension kit pieces, place a bead of sealant outside the 5" flex pipe collar (C) - the end with
the EXTERNAL lip. and slide it inside the 5" pipe on top of the stove (D). This is a snap lock connection.
Secure with additional screws.
NOTE: The snap lock connection is permanent, you will not be able to remove this pipe
once applied without
5. Place a bead of sealant inside the 8" flex pipe collar (E) . the end with the intemal lip - and slide it over the
8" pipe on top of the stove (F). This is a snap lock conneclion. Secure with additional screws.
6. lf addilional extension kits are being used, repeat steps 4 and 5, placing the 5" & 8" pipes onto the
previous extension kit.
Note: The minimum vertical dso is
from the connection on the stove
to the top of the pipe.
FIGURE 9
Refening to the above figure:
I{OTE: Attachment brackets are included with the termination kit. These optional brackets should be
screwed or nailed (screws not provided) onto the top and bottom of the 12 1/2" square opening, on the
exterior of the house. The termination plates then fit between these brackets, and using the screws
provided, screwthe brackets to the termination kit box (A). Attach the vinyl siding protector (G).
7. Apply a liberal bead of sealant around the outer edge of the plate (A), and place the assembly through the
12 1/2" square opening in the exterior wall. Place screws through the four slots (B) securing it in place.
8. Gently pull the 5" & 8' flexible aluminum down to the top of the extension kit, or the top of the unit if no
extension kits were used.
9. Place a bead of sealant outside the 5" flex pipe collar (C) and slide it into the 5" pipe on the extension kit
or top of the stove (D). Secure with additional screws.
NOTE: This snap lock is permanent, you will not be able to remove this pipe once applied without damage.
10. Place a bead of sealant inside the 8" flex pipe collar (E) and slide it over the 8" pipe on the extension kit
or top of the stove (F). This is a snap lock connection. Secure with additional screws.
11. OPTIONAL: Place insulation between the 8" pipe and the wall studs.
/r .ffi\
n[mb K
@r' @'
o
Cteo.once
Page '11
Prepare the chimney:
1. Gently stretch the 5" & 8" flexible aluminum pipes on the termination kit (#844 or #841i) and on each
extension kit, if used, the lengh required so when all the sections are connected together, the chimney
height for your installation is affained.
lMPORTANT:
DO NOT STRETCH THE EKIENSION KlT BEYOND 6" DO NOT STRETCH BEYOND WHAT IS REQUIRED. IT
IS VERY DIFFICULT TO RECOMPRESS THE FLEX PIPES ONCE STRETCHED.
2. lf your chimney is 8' or less from the stove top and doesnt require an extension kit, proceed to the '
Connect the chimney to the stove' section.
3. lf your chimney termination will.require one or more extension kits (1846), proceed with.thefollowing
steps. Each #8,16 extension kit contains enough 5" & 8" flexible aluminum pipe to extend the chimney an
additional 6'.
Connect the chimney sec'tions:
1. Place a bead of sealant outside the 5" flex pipe collar on the termination kit (#844 or #845) and slide
inside he 5" collar. the end with the intemal notches. on the extension kit Secure with additional screws.
2. Place a bead of sealant inside the 8" flex pipe collar on the termination kit (#844 or #845) and slide it over
the 8" collar - the end with the extemal notches - on fte extension kit. Secure with additional screws.
3. lf additional extension kits are being used, connect the 5" & 8n flex pipes on each extension kit together in
the same manner as described in steps #1 & #2.
Gonnect the chimney to the stove:
A firestop should be secured to the 12 1/2" x 12112' ftamed opening whenever passing the chimney through
a ceiling or roof.
NOTE: The framing and supporting chase for the termination kit should be at least partially complete.
1. Place a weighted rope around the end of the 5" & 8" flex pipes and carefully guide them down the chase
to the top of the stove.
2. Apply a liberal bead of sealant around the outer edge of the plate (A) , and place on top of the chase.
Secure using the screws provided.
Pge'.2
3. The restric'tor plate (included) must be placed inside the 5" flue collar on the top of the stove before
connection of the chimney to stove is made. This is required for vent runs of 15' . 40'.
a. Bend the (3)tabs on the restrictor plate required for your installation far
enough so that it will securely fit inside the groove on the 5" collar on the
stove. (Note: The tabs should be in the 'up' positlon.)Refer to figure #10
below.
4. Connect the flex pipes to the stove as follows: Place a bead of sealant outside of the 5" flex pipe collar
(end should have external lip) and slide it inside the 5" pipe on the stove. This is a snap lock connection.
OPTIOIIAL: Secure with additional screws.
5. Place a bead of sealant inside the 8" flex pipe collar (end should have an intemal lip) and slide it over the
8" pipe on the stove- This is a snap lock connec{ion. OPTIOML: SecurE with additional screws.
6. OPTlOllAL: Place insulation around the 8" pipe.
Figure 10
Page 13
D) FAN TNSTALLATTON (OPTTONAL)
INSTATLATION OF THIS FAt{ SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER.
IMPORTANT: lF THE FAN lS ]NSTALLED AFIER UNIT I]{STALLATION, THE LOWER GRILL MUST BE
REIIIOVED TO PROPERLY INSTALL.
NOTE: lf a fan is going to be installed, the wiilng must be done prior to enclosing the sides of the unit. A
removable electrical box panel is pr*installed in the flreplace and a receptacle and cover is included in the
fi replace componenb packel
IIIIPORTANT: CODE APPROVED LINE VOLTAGE WRING 16 GAUGE OR BETTER MUST BE UISED
WHEN WRING THIS SYSTEM.
WARNING: Ihis appliance is equipped with a threeprong (grounding) plug for protection against shock hazard
and should be plugged directly into a properly grounded threeprong receptacle. Do not cut or remove the
fromthis
Your optional fan kit includes:
1. Right and left fan assemblies with fan and limit switch already mounted.
2. Gomponents package: lncludes speed with mounting bracket, nut & knob*,
(4) nuts, installation instructions.
NOTE: To wall-mountthe speed con0ol, you will need to purchase: (1) Elecldcal box
Cover/ switch
I}ISTALLATION INSTRUCTIONS. REFER TO FIGURE #11.
NOTE: The fan will not operate unless the speed control has been turned on. The fan will not tum on until
sufficient heat is applied to the thermostdic control switch (C). The fan will turn on and off automatically
when the fireplace heats and cools. Adjust fan to desired speed while it is running.
,VO'E flris stsLn, l|tr q, insbtld, nust be dec,ttcaw gqnd€d ln accortarr(€ with bc,,l 6dgs, q in tho .hs€,tct of locat codes, with the National
Ehcj'ial Cde IIilSUNFPA TGCw|f,rt dltlorr.
FIGURE II
1. Slide the right fan(with receptacle) (A) through the lower gdll opening and place over the (2) right side
mounting studs (B) located tonards the back ofthe unit.
2. Slide the remaining fan assembly through the lower grill opening and place over the (2) left mounting
studs (B) located towards the back ofthe unit.
3. Place nuts on mounting studs and tighten.
4. lnstall electrical box and mount the speed conbol on a wall, if desired.
5. Snap the receptacle into the cover (included in the components packet included with this fiteplace).
6. Insert 115V wiring (with ground) through the romex connector installed in the electrical box in the side of
the unit and wire to the receptacle.
7. Place the cover on the electrical box (in the side of the unit) and secure with screws.
E. Place the thermostatic control switch (C) on the boftom of the unit, directly behind the control valve.
9. Plug fans together by inserting the threeprong fan cord on the left fan assembly into the receptacle in the
right fan assembly.
10. Plug cord (E) into receptacle in the electrical box.
1 1. Tum on/off soeed control clockwise until it clicks.
Page 15
E) RUN THE GAS L!NE.
GAUTION: Installation of the gas line must only be done by a qualified percon in accordance with local
codes.
This unit is equipped with a 3/8" flexible gas line connection 18" long.
NOTE: The gas line should be run to the point of connec'tion where the manual shut off valve and flexible gas
line will connect.
CAUTION: The manual shut off valve or flexible gas line must not extend outside the unit cavity. See the
WARNING label affixed to the flexible gas line for additional installation instructions and wamings.
1. Run the gas line. An accessible shut off valve (included with the unit) must be installed up stream
from the regulator.
IiIPORTANT: DO NOT RUN THE GAS LINE lN A ItlAl{NER THAT WOULD OBSTRUCT THE OPERATION oF
THE OPTIONAL FAN.
2, This unit is designed to accept either a 3/8" ot 1/2" gas line approved for gas appliances. Consult
local building codes to properly size the gas supply line leading to a 3/8" reduction. Also, see the chart on
page #17 for proper supply line sizing.
3. A gas line knockout is positioned on either side of the unit to run the gas line to the unit cavity.
4. Connecl the manual shut off valve to the prevlous run gas line.
5. Connect the flexible gas line (installed on the millivolt board valve) to the manual shut off valve.
IMPORTANT:
ALL CONNEGTIONS WHETHER FIELD OR FACTORY IIADE ]IIUST BE CHECKED FOR LEAKS.
NOTE: This appliance and its Individual shut off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psi.
NOTE: This appliance must be isolated from the gas supply piping system by closing its individual manual
shut off valve during any pressure testing of the gas supply piping systems at test pressures equal to or less
than
1/2 psi.
Pressure check taps for both the manifold (outgoing) and inlet (incoming) pressures are located in front of
the gas valve. The left pressure tap is the manifold pressure and the right pressure tap is the incoming
pressure. Follow instructions on page # 26 for checking these pressures.
Page 16
IIATURALGAS ONLY:
The minimum inlet gas supply pressure: 5,0 inches w.C.
The maximum inlet gas supply pressure: 10.5 inches W.C,
tlanifold Prcssure: 3.5 inches W.C.
Manifold Preesure (lo sefring): 1,7 inches lV,C.
Odfice size (0.2000 ft): 30 lnput rating: 39,000 BIU
LP @{S Or{l.Y;
Tho minlmum inlet gas supply pressure: ll.0 inches W.C.
The maximum inlet gas supply pressure: 13.0 inches WC.
llanifold Pressure: 10.0 inches W.C.
Manffold Presure (lo sefiing): 6.4 inches w.c.
Oilcs slze (G2000 ft): 4'9 Input nting: 35,500
fu hloh altifude insblhtiurs. consult he local Ms distibutor or Arc tor orcoer ntino methods.
Tubino sbs ilaximum run
SOLUTION TO EXAI'PLE Gos Meter
(l) llarimum demand for outlet "A' 30 CFH
llaximum demand for outlet "B" 25 CFH
ilaxlmum demand for outlet 'C" 75 CFH
llarimum demand for outlet "0" 136 CFH
Furnoce
136000 BTUlhr
t0'
70'
100'
12t
1n'
3/1"
Wtx
30,000 BIU/hn
SCALE l=5
TOTAL DE]IIAND 266 CFH
(2) The length of pipe from the gas me{er to the most remote outlet (outlet "A") is 60'.
THIS IS THE ONLY DISTANCE USED.(3) Uslng horizontal line marked 60', outlet'A'supplying 30 cubic feet an hour requires % inch pipe.
Outlet "B" supplying 25 cubic feet an hour requires % inch pipe. Sectlon I supplying outlets ..Ao & "8", 55
cubic feet an hour requires % inch pipe.
Page 17
F) MILLIVOLT BOARD INSTALLATION. See Figure 12.
NOTE: This unit is equipped with the millivolt board system already installed. Follow these procedures
should the board need replacing or is removed for servicing or fan installation.
MILLMOLT BOARD REMOVAL:
1. Tum the black control knob to the 'OFF' position.
2. Shut off the gas supply at the manual shut off valve.
3. Disconnecl the flexible gas line ftom the manual shut off
valve.
4. Disconnect any remote control, wall switch or thermostat
wires from the valve.
5. Remove the upper grill, valance & glass assembly.
6. Remove the log set and set aside where they will not be
7. Loosen, but do not remove the (2) nuls securing the bumer plate to the millivolt board and remove the
bumer plate (figure 12).
8. Loosen and remove the (8) 1/4" nuts and while grasping the board, gently lift it off the (8) bolts and
remove the board from the unit (ftgure 12A).
1
I,
Figure 12
S€CURE BURNER
wrTl{ Tvl/o 1/4" NuIs CAUTION: lf the bumer and/or pilot has been buming, the logs will
be warm and will continue to hold heat Place them on a protected
suface upon removal to avoid damage to floor or personal
SECURE MILLIVOLTBOARD
w'fi ElG0-rI 1/+Nnrs Figure 12a
Page 18
' INSTALLING THE MILLIVOLT BOARD:
NOTE: The millivolt board is fifted with a gasket to seal the board. Make certain this gasket is properly
placed around the opening before installing the millivolt board.
1. Grasp the burner with both hands and place into the unit, lining up the eight 1/4" holes to the mounting
studs. (Figure 12a)
GAUTION: BEFORE SECURING THE BOARD INTO PLACE, MAKE CERTAIN THAT ALL OF THE WIRES
(ATTACHED UNDER THE BOARD) ARE CLEAR AND UNOBSTRUCTED.
2. Attach the 1/4" nuts (included with the board assembly).
3. Place the bumer plate assembly onto the millivolt board, aligning the notches to the horizontal mounting
studs and aligning the burner tube over the bumer orifice.
4. Check that the bumer tube is properly seated over the bumer orifice. (Figure 12)
5. Secure the burner plate with one nut on each side. (Figure 12)
6. Connec't the flexible gas line to the manual shut off valve.
7. Reconnect any remote control, wall switch orthermostat wires.
8. Replacethe logs. Referto pagef20.
9. Replacethe glass assembly. Referto page#6.
10. Vedfy proper operation of unit and log position.
IITIPORTANT: CHECKALL WHETHER FIELD OR FACTORY IIADE FOR LEAKS.
Page 19
G)LOG INSTALLATION. See Figure 13.
rhisrogsetincrudes:
llliB-Itr
(1)AY-Log
(1)Bc-Log
(1)M-Los (2 pc.)
(1)E-La
(1)BD-Log
(1)M-Log
NOTE: THE CORRESPONDING LETTER(S)FOR THE LOGS ARE PRINTED ON THE
BOTTOM OF EACH LOG.
BASE LOG INSTALLATION:
1. Position base logs onto the bumer cover in the
following order
'BC'log,'BB'log, 'AX'log (2 pc.), 'AY'log, and
'M'log.
NOTE: The'BB'log extends onto the plate extension.
Prcss the logs onto the mounting pins to secure them
in place.
IIIIPORTANT: D0 NOT ALLOW THE LOGS TO
COVER THE BURNER OR BURNER PORT HOLES.
Figure 13
TOP LOGS INSTALI.ATION:
1. Position the 'AP' log, 'BD' log, and 'E; log
over the base logs as shown.
KLINKER INSTALLATION:
Place klinkers as desired on the left and right open areas in the firebox after the millivolt board and log set have been
installed.
GAUTTON: DO NOT PLACE KLINKERS ON THE MILLIVOLT BOARD, BURNER COVER OR BETWEEN THE LOGS.
INITIAL BURN PERIOD
NOTE: During the initial burn period, the logs and refractory will discolor. This is normal and part of the curing process.
Once the curing process is complete (approximately 2.4 hrs.) the true color will retum.
DO NOT BURN THIS FIREPLACE WITHOUT THE GLASS ENCLOSURE IN PLACE.
*MAKE SURE THE HOMEOWNER IS AWARE OF THIS*
Figure 13A
Page20
H) THERMOSTAT - WALL SWTCH . REMOTE CONTROL INSTALLATION (optional).
GAUTION: DO NOT connect high voltage (115 V) wire to the switch.
1. lf desired, a thermostat, wall switch gg remote
control unit may be used to tum the unit off and on.
Onlv one of these mav be installed. Follow
instructions included with each kit.
NOTE: lilsrAtLAnol 0F A THERmoSTAT oR wALL
SWTTCH SHOULO OI{LY BE DOIIE BY A QUALIFIED
INSTATLER.
2. Run low.voltage (themostatlwirefiomthe on/off
switch, to the desired location of the thermostat or
wall switch. Do not run wire more than 30'.
IIOTE: lf too heavy of wire is used or run more than
30', the electricig generated by the unit's generator
will not be suffcient to make the regulator work
propedy.
ITIPORTANT: No high voltage (115v)is required to
operate any ofthese systems.
Remote Gontrol Wiring Diagram
Flgure l4A
The on/off rocker switch on the
millivolt board must be in the 'off
position if any of the above systems
are installed on the unit.
Note: The fireplace must be turned 'on'
and 'off by the same method. For
example: lf the fireplace is turned 'on'
by the remote, it must be turned 'off
by the remote.
Figure l4B
P4e21
D COMPLETE THE TNSTALLATTON
1. Gomplete the fireplace walls and the unit facing.
Optional edging brackets are available.
GAUTION: THE SURROUNDING tlUOOD CHASE 0F
THE OUTSIDE WALL l,lUST BE INSULATED TO
PREVENTCOLDAIR FROITI ENTERING THE ROOM.
2. THIS STEP SHOULD ONLY BE DONE BY A
QUALIFIED INSTALLER OR SERVICE TECHNICIAN:
A) Perform lighting and shutdown procedures as
described on pages#24-25. This should be done prior
to replacing the glass so that any necessary
adjustments can be made and proper operation verifi ed.
3. Replace the glass assembly. Figure 15.
A) Align lhe slots in the top of the glass assembly over
the tabs on the fireplace.
B) Place the glass assembly so it is flush with the front
of the fireplace front.
C) Secure the assembly to the fireplace by pulling the
spring-loaded latch rods out, then up and releasing
them onto the brackets securing the glass assembly
(located under the firebox).
WARNING: DO NOT OPERATE THIS
FIREPLACE W]TH THE GLASS ASSEMBLY
REIIOVED, CRACKED OR BROKEN.
Replacement of the glass assembly should
be done by a licensed or qualified service
4. Install the lower grill. Refer to Figure 16.
A) Place one of the bolts through the hinge in the lower
grillopening (A) & attach the 1/4'nut (B).
B) Repeat for remaining hinge.
D) Tighten both 1/4'nuts.
The grill is now in place and may be lowered
for lighting purposes, etc.
5. Install the upper grill. Refer to Fig. 15.
A) Line the rods of the grill up with the upper holes.
B) Place the rods in the holes and push up untillhe
bottoms of the rods clear the valance.
C) Place the bottom of the rod into the lower holes and
release. The grill will set down into place.
6. Slide the rubber thumb grip onto the damper control
handle. (lncluded with components packet.)
FIGURE 15
FIGURE 16
HAND LES
Page22
J) DAMPER CONTRoL OPERATTON
This unit has been designcrtified to be operated wtth the damper in the fully opened or ompletely closed positions,
depending on the heat output desired.
To reduce the amount the heat entering the rcom, pull the damper conkol handle (A) down and slightly to the lefi to the
fully open position. This allows more of the heat generated to exit tuough the flue nather than into the home through the
upper grill.
lf more heat is desired, slide the damper control handle (A) slightly to the right and release to it's original position.
NOTE: The damper psition is located in fie upper prtion of the firebox and may be visually checked by looking through
the front viewing glass. Refer to ltem (B) in the figure belou
FIGURE 17
Page 23
K) LTGHTTNG & SHUTDOWN
NOTE: Prior to lighting, check all fittings for leakage. This is accomplished by applying soapy water on all
connections made. lf there is any leakage, bubbles will appear at the point of connection. lf bubbles occur,
tighten the fiftings until the bubbles no longer appear.
IMPORTANT: TEST ALL CONNECTIONS WHETHER FIELD 0R FACTORY MADE.
NOTE: The appliance and its individual shutoffvalve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of % psi.
NOTE: The appliance must be lsolated from the gas supply piping system by closing its individual manual shut
off valve during any pressure testing of the gas line at test pressures equal to or less than 1/2 psig (3.5 kPa).
Pressure check taps for the manifold (outgoing) and inlet (incoming) pressures are located in front of the gas
valve. The right pressure tap is the manifold pressure and the left pressure tap is the incoming pressure. Follow
instructions of page 26 for checking these pressures.
Read 1-8 before lighting the unit for the first time. Refer to ftgure 18, page 25.
Open the lower grill by grasping the center of the top louver, and pull out and down.
Set the thermostat, if used, to the lowest setting
Tum off all electric power to the appliance.
Push in control knob (A) sllghtly and tum clockwise r to "OFF"'
NOTE: Knob cannot be turned ftom "PILOT" to "Off unless knob is pushed in slightly. Do not force.
5. Waitfive(5) minutestoclearoutanygas. lfyouthensmell gas,STOP! Followthesafetyinformation
on page I of this installation manual. lf you dont smell gas, go to the next step.
Find the pilot - follow metaltube fiom gas control. The pilot is behind the
bumer tube inside the combustion chamber.
Tum the control knob on gas valve counterclochrise r to "P|LOT'.
n flell
wu-ia{ Tr
Push in the control knob all the way and hold in. Press the piezo igniter button (C). The pilot will
generally light with two or three pushes on the igniter. Hold the knob in for about one (1) minute after the pilot
is lit Release knob and it will pop back out. Pilot should remain lit. lf it goes out, repeat steps 4 through 8.
* lf knob does not pop out when released, stop and immediately call your service
technician or gas supplier.* lf the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and
call your service technician or gas supplier.
9. Tum gas control knob counterclockwise r to "ON".
10. The bumer can now be tumed 'on' or lit by depressing the 0N/0FF rocker switch located beside the
valve (B) 0R by setting the thermostat or remote control to the desired setting.
NOTE:
1.
2.
3.
4.
6.
7.
8.
Page24
,lOTEr Wf,rn the unit is initially lit, condensation will appear on the glass, this is normal in all gas fireplaces,
and will disappear in one to three minutes.
TO TURN THE BURNER OFF:
To tum the burner'OFF', depress the ON/OFF rocker switch to 'OFF', flip 'off the nall switch or adjust the
sefting on the thermostat or remote control. NOTE: The pilot will stay lit.
TO TURN THE PILOT OFF:
To tum off the pilot, push in and turn the control knob to the "off' position. DO NOT FORCE.
WARNING: This control valve has an interlock device. After tuming off the pilot, it cannot be relit until the
thermocouple has cooled, (approximately 60 seconds).
FrG.18
I{OTE: A PAINT SMELL WILL OCCUR DURING THE FIRST FEW HOURS OF BURNING. lT lS
RECOMMENDED TO LEAVE THE FAN OFF DURING THIS PERIOD AS THIS WILL SPEED UP
THE PAINT GURING PROCESS.
INTTIAL BURN PERIOD
DUE TO THE MAKEUP OF THE LOGS & REFRACTORY, THE CURING PROCESS MAY TAKE UP TO 4 HOURS OF BURN
TITE. DURING THIS PERIOD, THEY WILL DISCOLOR. ONCE THE CURING PROCESS IS COMPLEIE, THE TRUE
COLOR WLL RETURN. DO NOT BURN THIS FIREPLACE WNHOUT THE GLASS PROPERLY IN PLACE.
*I'AKE SURE THE HOMEOWNER IS AWARE OF THIS*
NOTE: Children and adults should be alerted to the hazards of high surface temperature and should stay
away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the
same room as the appliance.
Clothing or other flammable material should not be placed on or near the appliance.
Page 25
PRESSURE TESTING
MANIFOLD & INLET PRESSURE
IMPORTANT NOTICE: A pressure check tap for both the manifold (outgolng) and inlet (incoming) pressure
has been incorporated into the valve. The right pressure tap is the manlfold pressure and the left pressure
measures the Follow the instructlons below for testi
TO CHECKTHE MANIFOLD PRESSURE:
'1. Light pilot.
2. Loosen the manifold proasuro tap [C] by turning tho screw counter-clockwise.
3. Attach manometer to pressure tap uslng a 5/16' LD. hose [E].
4. Turn black control knob [A] to the 'on' position.
5. Tum the bumer on by depressing tho rock€r switch [B] to expose the 'red' and note manometer reading.
5. Tum the rocker swatch [BI to the 'off posltlon.
6. Dasconnect manometer hose and tlghten screw (clocltwise).
Screw should be snug, do not over tlghten.
7. Attach manometer to manifold prsssuna tap to verify that it is completely sealed.
Manometer should read no pntssuro when the rocker swltch ls tumed on..
NOTE: lf manifold pr€ssure reading ls within the normal rango, an lncoming pressure check is not necessary.
A too high or too low pFassuro roading warrants an Inlet (lncomlng) gas pressure check.
TO CHECK THE INLET PRESSURE:
1. Loosen Inlet pressure tap screw [D] by turning screw counter+lockwise.
2. Attach manometer using a 5/16' l.D. hose [E].
3. Light the pilot
4. Tum the black control knob [A] to the 'on' positlon. (Bumer should not come on) and note manomoeter
reading.
5. Tum the rocker switch IBI to the 'on' position and check the pressure to ensure that it stays near the
maximum inlet prossurs.
6. Tum the rocker switch [B] to the 'ofP position.
7. Tum the pilot to the 'off position.
8. Disconnect hose and tlghten screw (clocl$lse). Screw should be snug, do not over tighten.
9. Relight pilot and tum the control knob [Al to the 'on' posltlon. Attach manometer to the inlet pressure tap
to verify that it is complotely soaled. anometer should read no prsssurc.
NOTE: lf Inlet pressure reading is too high or too low, contact the gas company. Only a qualified gas service
technician should adjust the Incoming gas pressura.
CAUTION: A LOW PRESIIURE READING CAI{ CAUSE DELAYED lGilmON.
o
FIGURE 19
Page 26
'L) MATNTENANCERESUTREMENTS
1. The appliance should be inspected at least once a
year by a professional service person.
NOTE: INSTALLATION AND REPAIR SHOULD BE
DONE ONLY BY A QUALIFIED SERVICE PERSON.
THEAPPLIANCE SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A QUALIFIED
SERVICE PERSON. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE LINT
FROM CARPETING, BEDDING MATERIALS, ETC. IT
IS IMPERATIVE THAT CONTROL COMPARTMENTS,
BURNERS AND CIRCULATION AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
2. The mmpartment below the firebox (behind the
lower grill) must be cleaned at least once a year, morc
frequent cleaning may be required due to excessive lint
from carpeting, bedding materials, or other fibrous
materials. lt is imperative that the bumer be cleaned
once a year.
FAN
The fan should be disconnected from electrical cunent,
and cleaned (vacuumed) every six months. The
bearings are sealed and rEuire no oiling.
VENT SYSTEM
Annual examination of the venting system by a
qualified agency is required.
1. Remove the glass on the front of the unit.
2. For easier access, remove the logs.
3. Cover or remove the millivolt board.
4. Open the damper by-pass.
5. Examine proper sealing of the vent system.
6. Close damper by-pass.
7. Replace the logs, glass and upper grill.
IMPORTANT: ANY SAFETY SGREEN OR GUARD
REIIOVED FOR SERVICING MUST BE REPLACED
PRIOR TO OPERATING THE APPLIANCE
CAUTION: LABEL ALL WRES PRIOR T0
DISCONNECTION WHEN SERVICING CONTROLS.
WRING ERRORS CAN CAUSE IIIPROPERAND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
MILLIVOLT BOARD SYSTEM
1. Annual cleaning of the bumer is required. The
bumer tube / cover may be removed for easier access.
2. Remove the logs.
3. Remove the bumer tube / cover by loosening the two
nuts securing it on each side of the bumer cover.
4. Visually check for blocked port holes, especially near
the pilot. Blocked port holes may cause delayed
ignition.
5. Visually check the pilot light and bumer when
they are buming. See Figures above and below. The
flames should be steady, not lifting or floating.
Burner Orifice
GLASS CLEANING & REPLACEMENT . Glean glass only when cool and only with
non.abrasive cleansers.. Do not operate this fireplace with the
glass/frame assembly remove, cracked or
broken.
Replacement ofthe glass & gasket
assembly, must only be performed by a
licensed or qualified service person. DO
NOT SUBSTITUTE MATERIALS.
Do not strike or slam glass assembly
shut.
CAUTION: KEEPTHEAPPLIANCEAREACLEAROF
COMBUSTIBLE MATERIALS, SUCH AS GASOLII.IE
AND OTHER FLAilMABLE VAPoRS AND LIOUIDS.
t-1 v @ e M L-,/
ffi Pilot
Page27
M) TROUBLE SHOOTTNG GUTDE
NOTE: The r€gulator board includ6 the following itsfir9: Regulator, generator, pilot, piezo, electrode, rocker switch, bumer, orilice
and orifice holder. lf any of th6o items are dEfectivg contact your dealer for the appropriate repair I replacement procedut€s to
follow.
WARNING: D0 NOT ATTEMPI T0 SERVICE THIS UNIT lF YOU ARE NOT A OUALIFIED INSTALIER 0R REPAIRMAN.
1. lf the unit fails to lgnlte a qualified service person should check the unit installation.
2. ]t is lmperative that the confol compartment, bumer and circulation air passagernys of the unit be kept clean. This is
necessary to provide adequate combuslion and vonlilation air.
3. All of the rwrklng paft of this unit can be removed at one time. Eefore removing regulator board, check for loose wires.
PROBLEM
Pilotwon't light
Pilot rvont shy lit
CAUSE
Gas shut 0ff.
Gas line not bled out
Not holding regulator Yalve
in long enough.
Not holding pilot button in
long enough.
Generator wires loose at
valve terminals.
Generator wire grounded out
due to pinching ofwires
Generator or Thermocouple has
film build-up on tip.
Pilot orifice blocked.
SOLUTION
Tum Gas'0n',
Hold valve knob in long enough to
bleed out line.
Hold in longer.
Hold button in longer to
heat generator,
Reposition wire and tighten scrers.
See Fig. 20 for widng diagram.
l,lub on millivolt board may need
to remove pinched wire. See Fig. 13.
With the generator and
thermocouple
tips cool, clean the upper 3/8" with
a very fine emery cloth.
Replace orifice with a new orifice of
the exact size and type.
- rcl9 coDacl d orct t/'c'rEn'iA,d.6.
Figure 20
Page 28
, PROBLEM
a 'i '
CAUSE SOLUTION
The nutwhich holds the piezo Tighten nut
in place is loose.
Wire on back of plezo button Put wire back into place.
is loose or 0ff.
Wire from piezo to electrode is Reconnect wire.
loose at electrode,
Elecfode moved out of position. Reallgn electrode with 1/8" space
between it and pilot
Relight pilot
\
l{o spark when piezo
buton is depressed
Bumerwon't light Pilot not lit
O Bumermntsravtit
Flame too blue after Bumer fube venfuri open too far. Gonhc{ qualified sewice person to
lSminutesof buming. adjustventuri. Approximately3/8"
open-LP gas & 1/8" - 1/4'- Nat gas.
Caton build up inside of Incorect log placement Check log placement, adjust
fireplace.
Bumer fube ventud closed too far. Conhct qualified service person to
adiust venturi.
Valve not furned lo 'on', Tum valve to "on".
Rocker switch not tumed 'on'. Press bottom of switch exposing the
"on" indicator.
Rocker swibh wires not Check widng diagram Figure 20 and
connecfed.ensure that all wires are secute.
Remote contsol or bermostat Gonnect properly or disconnect and
not connected properly. and use the rocker switch only.
Remote control or thermostat Set to desired temperature setting,
setting too low
Wall switch or thermosht wires Disconnec{ wires. lf bumer sbys lit
too thick or run more lhan 30 ft. change location of wall switch or
thermosht or use lhe rocker switch.
Page 29
REPLAGEMENT PARTS
IMPORTANT: 1IESE REPUCEMENT PARTS ARE ONLY FOR Tllls FIREPLACE tilODEL AS MAI{UFACIURED. PREVIOUS ITIODELS
MAY USE DIFFERENT COTIPONENTS. OO NOT SUSSTFUIE COMPONENTS. COIITACT YOUR LOCAL DEAIER.
ALUIOLT BOARD ANO PARIS
9i12.700 illivolt board - l{atunl Gas 70009,1 Pilot Otince - Natunl Gas
942.701 ililllyolt boad - L.P Gas 7qn05 Pilot Orifice - LP Gas
700033 On Off Rocker Sryibh 700m6 Hillo Adiustable Regulstor - Natursl Gss
700080 l{atur.lca8. S.l,T. Gas Vako 700097 HULo Adlustable Regulator. LP Gas
700087 LP Gas - S.l.T. Grs Valve 700098 Pllot Hood
700088 Pilot , G€norator , Thermocouple Arsembly . Natural Gar 700099 Pi.zo lgnitor wih nut
700089 Pilot, Gsneralor I Thermocouplo Assembly - L"P Gas 700203 Xrnurl Shut ofivahs
700t91 Flellbls PllotTubing - (Valyo b pllotl 700213 FLribl. Grs Lins - 18'
700092 lillivolt G.nontor TWZll Florible Gas Lin€ -24' ( Valve to Bumer orifica connoction)
700m3 Th.mocouple 700230 *10 Bumor otinco - Natural Gas
700219 t49 Bumsr Odfice - LP Gas
900035 BumerTubo
942035A Eumer Cover
FAI{AIIDFA PARTS GRILL SEIS
4M llmit Sritch Asaembly (t611fan klt) 500351 Blact Grillset 600-l Fan Xit 500352 Brass Grill Set
600085 Speed Contol 500353 8ra3s Acc€nt Grills€t
600087 Speod ControlAssembly - D.shboard
UPPER & LOYUER GRILLS
RETOTE COilTROLS
'
NIERTOSTAI 3lllll3 Uppu Gdll - Black 79Sl Romot Confol ulth Themootat 301 I l,l Uppct Gtill - E]ars
7s7.1 R.mot! Contol 3llll15 Uppercdll- Brass Accent
f91-2 Remote Bracket - Dashboard m2111 Loty.r Gdll - Brass
700038 lYall-tlount Them6tat 84m€ Lorwr Gdll - Black
3112101 Lorwr Grlll- Brass Accent
GLASS
GI.ASS FRAXES & BRASS IRII
70001T Rephsemnt Ghlr Assembly - Includ6
21'r 3li'gl$r & gastot 942005 &chod Gla3s Frane
9110006 Tadpole gh$ gest t flt0042 Archod Erass Tdm (2 pc.)
912REC Rocbnguht Gla86 Frame
LOGS'(L XERS
'
REFRACTORY
TERTIINATIOI{ KIIS
'
PARTS
9,12508 8 pc. Log set W DV Teminrtion Nit - 6 ft 8B-Log 845 DV Tsmlnatlon Klt - 8 fr. 8C-Log 848 DV Ertsn3lon l$ - 0 ft. BD-Log U7 VinylSldlng Prctoctor AP-Log
842-060 File3top AI-Log
9425EA Restlcior (lt - 40'vertcaltemlnatons) AY-Log
AZ.Log
E{oS
900KLK Kllnksts
|SCELLA EOUS $4004 'l pc. Rofnctory Bdck Panols
617 Lir ol lmn GAS CONVERSION KIT
300624 12 oz. Asrosalbuch-up paint - Saiin Elack
OCK€:10 l{fhlral Gas Conve6ion Kit
OCK-S,$ LP Gar Gonversion Kit
TTVIN I{ESH DOORS
9,|2.NDOR Traditional Twin ltlesh Doors
942.PooR Prairie Style Twin flesh Doo6 TTANUFACTURED BY:
Husswrg llanuf€c'fing ConPanY, lnc.
PATEMr #5.931.151,#tt.961.139,*6.NH.193 Zg4lndustlal Paft Dive
Lahefreld. NN 56150
nodel#Uz DV - US INSTAUAnONS ONLY urvvkozyheaLcom RaYEiod Juty 2000
a
Page 30
-..4r/.. &./**ot
--Jlrl--"KozvHEAr Town of Vail
gFNf,Ef;OPY INSTALLATION & OPERATIN
MODELS:
ffifa
f932 DIRECT VENT WALL-FU
#936 DIRECT VENT WAIL- FL
PATE'{| PENDING
PATEM f5.931.154
lITPORTANT:
READ INSTRUCTIOI{S CARER' I,IY BEFORE IIISIATJ.ATION.
FAILURE TO INSTAU. I}II{i RREPITGE CORRECNY CAN
CAUSE SERIOUS SIRUCruRAL AND FIRE I{AZARDS AND
IIAY VOIO YOUR WARM,IITY.
Warnock Hersey llt It6r US
Ynvln koryheatcom
ocToBER 1999
INDEX
DESCRIPTION
SAFEWREQUIREMENTS/SPECIFICATIONS .........2
MINIMUMCLEARANCES.. 3
GASCONVERSIONS ....... 3
PREPARETHEUNIT .......4
POSTTIONTHEUNTT .......5-6
ROUGH-INCHIMNEYVENTDIMENSIONS.... 6
ROUGH-IN DIMENSIONS .... 6
VENTING REQUIREMENTS ......7-10
DIRECTVENT KIT INSTALLATION 9
FANINSTALLATTON .....11-12a
GAS LINE SPECIFICATIONS . ... 13-14
MILLIVOLTBOARD REMOVAL/INSTALLATION . ..... 15-16
LOG INSTALLATION . .... 16-18
WALL SWITCH - THERMOSTAT - REMOTE CONTROL INSTALLATION . . . . . . . 19
COMPLETE THE INSTALLATION 20
LIGHTING&SHUTDOWN.. ..,,.21-22
MANIFOLD & INCOMING PRESSURE CHECK PROCEDURES . . . 23
CLEANING & MAINTENANCE REQUIREMENTS 24
TROUBLE SHOOTING ... 25-26
REPLACEMENT PARTS LISTS 27
o
-3
.l
Page I
IMPORTANT:
nrno ruts nllnnum ee
MODELS #932 DV & #936 DV WALL FURNACE
INSTRUCTIONS INSTALLATION
This appliance has been tested to and complies
with ANSf 72'1.88-1988aCSA 2.33-M98, "VENTED
GAS FIREPLACE HEATER". Installation must
conform with local building codes, or, in the
absence of local buitding codes, with the national
fuel gas code, ANSI 2223.1 NFPA 54, Curent
Editlon, or the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280.
This appliance may be installed in an aftermarket
permanently located, manufactured (mobile) home,
where not prohibited by local codes. This appliance is
only for use with the $pe(s) of gas indicated on the
rating plate. This appliance is not convertible for use
with other qases. unless a certified kit is used.
WARNING: Do not use this heater if any part has been
under water. lmmediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been under
water.
WARNING: Do NOT REPLACE THIS BURNER UNIT
WTH ANY OTHER SIZED BURNER. REPTACEMENT
WITH AN UNAUTHORIZED BURNER CAN RESULT IN
TEMPERATURES EXCEEDING THE LIMITS FOR THIS
UNIT, AND VOID YOUR WARRANTY.
I
A I
WARNING: lmproper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional
information consult a qualified installer,
service aqencv. or the
llsrnu-mon mo/oR REpAtR oF THts uNtt sHouLD oNLY BE
DONE BYA QUALIFIEO INSTALLER.
WARNING: lf the information in this manual is not
followed exactly, a fire or explosion may result causing
UNIT SPECIFICATIONS - #tt32DV #e36Dv
Height (A): 25" 32"
Front wldth (B): 32" 36"
Back width (C): 22" 26"
Depth (D): 18114' 18114"
Face to front of 7" intake: 7 314" 7 314"
Face to center of of 4" exhaust 11 114" '11 114"
Flue size: 4" exhaust. 7" lntake
o
a
a
o
a
o
FOR YOUR SAFETY:
WHAT TO DO IF YOU SMELL GAS:
Do not touch any electrical switches.
Do not try to light any appliance.
Do not use the phone in your building.
lmmediately call you gas supplier from a
neighbor's phone.
Follow the gas suppliers instructions.
lf you cannot reach your gas supplier, call
the fire department.
Do not store or use gasoline or other
flammable vapors and liquids In the
vicinitv of this or anv other
Page 2
Y
IMPORTANT: THESE UNITS ARE APPROVED FOR USE ONLYWITH ONE OF THE FOLLOWING DIRECT
VENT SYSTEMS :
o . #745 DIRECT VENT TERMINATION KIT - for
terminations 4' for less.
- #718 DIRECT VENT TERMINATION KIT - for
terminations greater than 4' but less than 8'.
#746 DIRECT VENT EXIENSION KIT - used in
conjunction with #745 or #718. The extension kit is
exoandable to 6'.
- SIMPSON DURA-VENT DV.GS DIRECTVENT
GHIMNEY SYSTEIII: 4" x 6 5/8". For vertical
terminations.
'Adaptor #923.G is required to adapt the flue
collars to the Dura-Vent chimney system.
Refer to pages #7 - # 10 for complete venting
installation instructions / requirements.
For visual inspection of proper vent connection; upon completion of installing the direct vent kit, remove the nuts
and the baffle inside the unit to expose the lower end of the flue gas exit.
IMPORTAI'IT: NON-COIIIBUSTIBLE FACING I|ATERIAL ilAY BE APPLIED OVER THE FACE. T0 PREVENT THE
FACING MATERIAL FROM CRACKTNG AND FALLING OFF DUE TO EXPANSION OF THE FACE WHEN HEATED, DO
NOTATTACH FACING IIIATERIAL DIRECTLYTOTHE FACE OFTHE UNIT.
CLEARANCES Mantel Projection
Minimum clearance to combustibles:
From unlt sldes & back:
From unlt top stand-off:
To flooring:
From flue vent:
From unit glazlng to adjacent sidewall:
From heat outlet to mantle:12"
z,
z,
o
J J u (,
o
o F
=o
I
18'
l7'
l5'
l3't?'
ll
l0'
9'
a'
GAS CONVERSIONS
lf a gas conversion is necessary, one of the following conversions kits must be used:
Natural Gas Converison Kits - used to convert an LP millivolt board to natural gas.
Model #932 - OCK-338 Model #936 - #OCK-331
LP Gas Conv66ion Kits - used to convert a Nafural Gas millivolt board to LP Gas.
Model #932 - OCK-353 Model #936 - IOCK-349
Tho conversion shall be carried out in accordance with the requirements of the provinclal authorities having
and In accordance with the roquirements of the ANSI 2223.1 installation code.
Page 3
o
. ej eneenRE THE uNrr
1. REMOVE THE UPPER GRILL
A. Remove the upper grill (A) by lifting it up far
enough to clear the bottom holes and pull the
bottom of lhe grill out.
REMOVE THE GLASS ASSEMBLY.
See Figure 1.
Open the lower grill and locate the spring-
loaded handles securing the glass
assembly (under the firebox).
Pull the handles out, then down to release the
glass assembly.
Pull the bottom of the glass assembly out and
lift up off the tabs (at the top).
Set aside where it will not be broken.
Remove the box of logs from the firebox and
set aside.
REMOVE THE LOWER GRILL.
(FOR OPTIONAL FAN INSTALLATION).
Grasp the center of the lower grill and pull
down to open.
Remove the 114" nuts (B) from the grill
assembly.
Pull the entire assembly out of the hinges(A).
Re-attach the 114" nuts (B) to the grill
assembly and set aside for reinstallation later
in this manual.
Figure I
2.
B.
c.
D.
E.
3.
c.
D.
Flgure 2
HANDLES
Page 4
B) POSITION THE UNIT. See Figures 3A & 38.
1. Determine the exact position of your fireplace.
lf possible, place the fireplace in such a manner
that the piping will be placed between two studs
so additionalframing is not necessary. Determine
the width, depth and height of the (optional)
hearth.
2. The unit may be installed on eitherthe outside
or inside of an exteriorwall. See Figures 3A & 38
for various installation options. Follow clearance
requirements listed above.
Figure 3A
CAUTION: COLD AIRTRANSFERAREA. THE
SURROUNDING WOOD CHASE OF THE
OUTSIDE WALL MUST BE INSULATED TO
PREVENT COLD AIR FROM ENTERING THE
ROOM.
NOTE: Due to high temperatures, this
unit should be located out of traffic areas
and away from furniture and draperies.
o
42t
NOTE:*=1/4"CLEAMNCE
ALL DIMENSIONS ARE MINIMUM
<a3 MODEL 936 --8
NOTE:t=1/4"CLEARANCE
ALL DIMENSIONS ARE MINIMUM
Figure 38
Page 5
3. Gut a hofe for the firestop, 9112" x9112'.
The top of this hole must be a minimum of:
-42112" * (A) . Model #932 DV
- 49112" * (A) - Model#936 DV
above the height of the hearth (optional).
See Figure 4A.
'lmportant: This measurement is
determlned by the venical height and
horizontal length of the venting
application desired. The measurement
is to the top of the plpe. Please refer to
pages *7 & # of this installation
manual lor requirements and
restrictions.
FIRESTOP
Fig.4A
4. Rough in the wall enclosure. The minimum rough opening dimensions are:
Model#!132 DV: 25 1/4'high (A)
32 1/2'wide (B)
'lB 112'deep
Model#936 DV: 32 1/4'high (A)
36 1/2'wide (B)
18 112" deep
Build the hearth to the desired
size, and height. See Fig.48.
Figure 48
NOTE: When the unit is installed directly on carpeting, tile, or other combustible materials other than wood flooring, it
must be installed on a metal or wood panel extending the full \ ridth and depth of the unit. The minimum for the support
platform under the unit is: Model #932DV:18 114'deep by 32" wide Model #936 DV: 18 1/4" deep by 36' wide. lf
masonry is to be used (optional), prepare the necessary foundation for the masonry load. When masonry construction
a lintel must be used over the toD of the unit to the added
NOTE: A non-combustible hearth extension is not required. lf a hearth extension is desired, combustible
materials may be used.
NOTE: Provide for a minimum of 6' of clearance in front of the lower grill. This will provide adequate space
for opening to open the lower grill and operate the controls.
Do not obstruct the upper and lower grill areas to allow proper ventilation air around the unit. Air enters lhe
unit at the lower grill, and exits at the upper grill. Blocking these passages may result in overheating the
fireplace creating a potentially hazardous situation.
5. Place the unit into position.
Page 6
G) VENTING REQUIREMENTS
IMPORTANT: MODELS #932 DV & #936 DV ARE APPROVED FOR USE ONLY WITH THE FOLLOWING
DIRECT VENT SYSTEMS:
HORIZONTAL TERMINATIONS
#7OO SERIES DIRECT VENT TERMINATION KITS:
-#745KOZY HEAT DIRECTVENT KIT - Forterminations of 4'or less.
- #718 KOil( HEAT DIRECT VENT KIT - For terminations greater than 4' but less than 8'.
- #746 KOZI( HEAT DIRECT VENT EXTENSION KIT #746 - Used to extend the
#7 45 or #7 18 kit an additional 6'. Used for horizontal terminations.
VERTICALTERMINATIONS
-SIMPSON DURA-VENT DV€S DIRECT VENT CHIMNEY SYSTEM ( 4" x 6 5/8").
- Used for vertical terminations only.
- Adaptor #923-C is required to adapt the flue collars on the unit to the Dura-Vent chimney system.
- Vent runs must be in compliance as outlined below.
- 45'elbows only - Follow Installation Instructions included with the #923-C adaptor & chlmney
system.
HORIZONTAL & VERTICAL VENTING CHART
Vertical Rise
32-
30-
27-
24' -
21'-
18' -
15' -
12-
9r_
a-
500 40"
22'.
18"
btu-siobON-$?o-coO
HorizontSl REn - al
PageT
MINTMUM VERTICAL RISE* FROM TOP OF UNIT: 18 lN. (to top of 7" pipe)
MINIMUM HORIZONTAL RUN: 6 lN.
MAXIMUM HORIZONTAL RUN: 20 FT. (Horizontal runs must maintain 1/4" rise perft.)
TOTAL HORIZONTAL & VERTICAL RUN MUST NOT EXCEED 32 FT,
*Miniminum vertical dsedirectlyoff the top of the unit isdetermined bythe length of the horizontal run. Refer
to the venting diagram on page 7.
1. #700 Series vent kits must be supported every
3 ft. to maintain proper rise.
2. NOTE: lF TERMINATING AGAINST VINYL
SIDING, A VINYL SIDING PROTECTOR, INCLUDED
WITH THE #745 AND #7.I8 DIRECT VENT KIT, MUST BE USED. FOLLOW INSTALLATION
INSTRUCTIONS INCLUDED.
3. IMPORTANT: OO NOT RECESS
TERMINATION KIT INTO OUTSIDE BUILDING
MATERIALS - brick, stone, etc. lf necessary,
extend framing so that termination kit will be
exposed once building materials are installed.
Fotlow Figure 5 for clearances to doors, wlndows
and ground level.
Fig.5
4. IMPORTANT: VENT TERMINATION MUST
NOT BE LOCATED WHERE IT WILI BECOME
PLUGGED BY SNOW OR OTHER MATERIAL.
5. Foreach additional elbow used afterthefirst
elbow, you must subtract 5 ft. from the maximum
horizontal run allowed.
For example: A vertical rise of 18" directly off the top of
the unit with a 90o elbow would be allowed to run 6' with
1/4" rise perft.. lf an additionalelbow is used within this
vent run, the maximum horizontal run allowed would be
1' with 1/4" rise per ff.. (6 fl - 5 ft. (for additional elbow)
=1ft.)
D = UNVENTID SOFFIT 3 = VENTEN SBFF IT
I-FIXED CL OSED
E -OPENABLE
A. l2' (30cn)
B. a4'(60cm)
c.84'(a.lM)
D. la' (30cn)
*lAr
rml
p--t lF I *.,f;ltE^
A,trt I I Ar.--f
l*r
I
!_-L r+
Page 8
TNSTALLATION OF THE #700 SERIES HORIZONTAL DIRECT VENT TERMINATION KIT(S)
NOTE: THE FLEX PIPE IS PERMANENTLY ATTACHED TO THE EXTEROR WALL PLATE. DO NOT ATTACH THE #745 OR
#718 Tenmnlr|oN Krr ro THE srovE (on exreNsnN xr) unrn F HAs pAssED THRoucH THE WALL. THE
TERMINATION PLATES SHOULD ALL BE INSTALLED 01{ THE EXIERIOR OF THE OUTSIDE WALL.
7a. OPTIONAL: Place insulation between the 7' pipe
and the wall studs.
7b. The flexible termination kit includes in interiorfirestop
assembly (G) shown on figure 44, page 6, which is
installed on the inside wall (over wall materials), around
he flexible pipe. Slide the firestop over lhe flex pipe witr
the spacer legs toward the wall. OPTIONAL: Apply a
liberal bead of sealant around the outside / wallside
edge and place over the 9 1/2" square opening.
7c. Secure each comer with a drywall screw. ( see figure
4A - page 6.)
L Genty pull the 4' & 7'flexible aluminum down to the
top of the exlension kit, or the top of the unit if no
extension kits were used.
9. Place a bead of sealant oubide the 4'flex pipe ollar
(C) and slide it inside the 4' pipe on top of the stove (D).
This is a snap lock connection.
NOTE: The snap lock is permanent you will not be
able to remove this pipe once applied without
1. lf yourchimneytermination is 8'or less from the stove
top and doesn't require an edension kit, proceed to step
number 6.
2. lf your chimney termination will require one or more
extension kits (part #746), proceed wi$ the following
steps. Each #746 extension kit contains enough 4'& 7"
flexible aluminum pipetoextend the chimney an additional
6'.
3. Using your extension kit pieces, place a bead of
sealant outside the 4' flex pipe collar (C) - the end with the
EXIERNAL notches - and slide it inside he 4' pipe on top
of the stove (D). This is a snap lock connection.
NOTE: The snap lock connection is permanent you
will not be able to remove this pipe once applied
without
4. Place a bead of sealant outside the 7' flex pipe collar
(E) - he end wih he EXTERNAL notches - and slide it
inside the 7' pipe on top of he stove (F). This is a snap
lock connection.
5. lf additional extension kits are being used, repeat
steps 3 and 4, placing he 4' & 7" pipes onto he previous
extension kit.
Refening to the figure below:
6. Apply a liberal bead ofsealant around he outeredge
of the plate (A), and, ftom the outside, place the exterior
wall assembly $rough he 9 % ' square hole. Place
screws through he four slots (B) securing it in place.
NOTE: Attachment brackeb are included wih the
termination kit. These optional brackets should be
screwed, or nailed (screws not provided) onto he top and
bottom of tp I %'square hole, on the exterior of he
house. The termination plates hen fit in between these
brackets, and using fte screws provided, screw the
brackets to the termination kit box (A). Attach the vinyl
siding protector.
10. Place a bead of sealant oubide the 7' flex pipe collar
(E) and slide it inside the 7" pipe on top of the stove (F).
This is a snap lock connection.
Note: The 18' minimum vertical
rise measurement is to he
&p of he f pipe.
Page 9
NOTE: MINIMUMVERTICALRISEFROMTOPOFUNIT: 18lN. (totopofT" pipe)
MAXIMUM VERTICAL RISE FROM TOP OF UNIT:32 FT.
ELBOWS: 45" only (Dura-Vent chimney sytems)
MINIMUM CLEARANCE TO COMBUSTIBLES:
WHEN VERTICALLY TERMINATING,
DETERMINED BY THE FOLLOWING
Roof Pitch Minimum Chimn€Y Heiqht
Flat to 6/'12 1 ft.
6l'12 ro 9112 ?fr.10112to12/12 4fl.
GAUTION: This gas appliance must not be connected to or joined with any
chimnev flue other aopliance.
Figure 7
DURA-VENT CHIMNF/
1'MINIMUM CLEARANCE
TO COMBUSTIBLES
32 FEET tldAx
THE MINIMUM CHIMNEY
CHART:
Roof Pitch
13112 to 18112
'17 112 to 21112
18" MINIMUM
HEIGHT ABOVE THE ROOFLINE IS
Minimum Chimnev Heioht
6ft.
8ft
",,''#,f i:Tsiis:lif#fr 5m",J"
Page 10
D) FAN TNSTALLATION
INSTALLATIoN oF THIS FAN SHoULD BE DoNE ONLY BYA QUALIFIED INSTALLER
IMPORTANT: lF A FAN lS GOING TO BE INSTALLED, lT MUST BE COMPLETED BEFORE
THE MILLIVOLT BOARD IS CONNECTED TO THE GAS LINE.
NOTE: lf a fan is going to be installed, the wiring must be done prior to enclosing the sides of the unit. An electrical
box is pre-installed in the fireplace and a receptacle & cover is included in the fireplace components packet.
IMPORTANT: THE LOWER GRILI- MUST BE REMOVED TO PROPERLY INSTALL THIS FAN.
NOTE: Gode approved line voltage wiring 16 gauge or better must be used when wiring
this system.
WARNING: Thls appliance is equipped with a three-prong (grounding) plug for protection against
shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do
not cut or remove the from this
This optional fan klt #932{t28 (Model #932) or #600.1 (Model #!t36) Includes:
1. Right and left fan assemblies with fans and magnetic limit switch already mounted.
2. Components Package: Includes speed conbol with mounting bracket, nut & knobt,
(4) nuts, installation instructions.
'NOTE: To wall-mount the speed control, you will need to purchase: (1) Electrical box
1) Cover / switch
Page 11
1. Remove the lower grill , if not previously removed. (Refer to figure 2, page#4.)
2. Slide the lefi fan (without receptacle) through the lower grill opening (rt. side of the valve) and place over the
(2) left mounting studs (B) located towards the back of the unit.
3. Slide the right fan(with receptacle) (A) through the lower grill opening (rt. side of the valve) and place over the
(2) right side mounting studs (B) located towards the back of the unit.
4. Place nuts on mounting studs and tighten.
5. Plug fans together by inserting the threeprong fan cord on the left fan assembly into the receptacle in the
right fan assembly.
6. Install electrical box and mount the speed control on a wall, if desired.
7. Snap the receptade into the cover (included with the lireplace components packet).
8. lnsert '115V wiring (with ground) through the romex connector installed in the electrical box in the side of the
unit and wire to the receplacle.
9. Place the cover on the electrical box (in the side of the unit) and secure with screws.
10. Place the magnetic limit switch (C) on the bottom of the unit, as close to the center as pssible.
11. Plug mrd (E) into receptacle in the electrical box.
12. Tum on/off speed control clocltwise until it clicks.
13. Reolace the lower odll. Refer to liqure 2, Daqe lr4.
INSTALLATION INSTRUCTIONS. REFER TO THE FIGURE BELOW.
NOTE: The fan will not operate unless the speed control has been tumed on. Adjust fan to desired speed while it is
running.
NOTE: The fan will not tum 'on' until sufficient heat is applied to the limit swttch (C). The fan willtum 'on' and 'offl
automatically wtren the fireplace heats and cools.
,VO'E: thrs systerrr, w[ q insb,ll4 mustbe e|€rficary gfro,unded ln accotdance wiut bcal cod*, or in lhe absence ol tocal cod6, yd t the llatioaal
E if,, Ccde, AnStNFPATEcmente Aon.
Figure 8
Page 12
E) RUN THE GAS LINE.
CAUTION: lnstallation of the gas line must only be done by a qualified person in accordance
with local buildinq codes.
NOTE: This unit is equlpped with a 3/8" x 18" long flexible gas connector and manual shut off valve.
NOTE: Thegaslineshouldberuntothepointofconnectionwheretheshutoffvalveandflexiblegas
line wlll connect.
CAUTION: The manual shut-off valve orfl€xible gas tubing must not extend outside of the unlt cavity. See
the WARNING label affixed to the flexible tublng for addltional installation instructions and wamings.
NOTE: For high aftitude installations consult the local gas disttibutor or the authority having jurisdiction for prcper
rating methods.
1 . Run the gas line. An accessible shut off valve must be installed up stream from the regulator.
NOTE: Do not run the incoming gas line in a manner that would obstruct the operation of the fan.
2 . This unit is designed to accept either a 3/8'or 1/2'gas line approved for gas appliances. Consult
local building codes to propedy size the gas supply line leading to a 3/8" reduction. Also, see the chart
on page #'14 for proper supply line sizing.
3. A gas line knockout is positioned on either side of the unit for gas line connection.
4. Connect the gas line to the manual shut-off valve.
5. Connect the flexible gas line (installed on the millivolt board valve) to the manual shut off valve.
Page 13
NATURAL GAS:
The mlnimum inlet gas supply pressure: 7.0 inches W.C. (recommended)
The maximum inlet gas supply pressure: 10.5 inches W.C.
Manifold pressure: 3.5 inches W.C.
Manifold pressure (lo sefting): 1.7 inches W.C.
Model #932 - Orifice size: 38 Input 26,000 BTU's Elficiency: 71.2o/o AFUE: 64%
Modef #136 - Orifice size: 31 Input 36,000 BTU's Efllciency: 74Tn AFUE: 67%
LPGAS..
The minimum inlet gas supply pressure: 1 1.0 inches W.C. (recommended)
The maximum inlet gas supply pressure: 13.0 inches W.C.
Manlfold Pressure: 10.0 inches W.C.
Manlfold Pressure (lo setting): 5.4 inches W.C.
Model #!132 - Orifice size: 53 Input 26, 000 BTU's Efficiency: 73% AFUE: 66.7%
Model #936 - Orifice size:49 Input 35,000 BTU'S Efficiency: 73% AFUE: 68%
The efiiciency rating of this appliance is a product thermal efficiency rating determined under continuous operating
conditions and was determined indeoenden$v of anv installed
o
IMPORTANT:
ALL CONNECTIONS WHETHER FIELD OR FACTORY MADE MUST BE
CHECKED FOR LEAKS!
NOTE: The appliance and its individual shutoffvalve must be disconnected from the gas supply piping
system during any pressure testing ofthat system at test pressures in excess of % psi.
NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than % psi.
Pressure check taps for both the manifold (outgoing) & inlet (incoming) pressures are located in front ofthe
gas valve. The top pressure tap is the manifold pressure and the bottom pressure tap is the incoming
pressure. Follow instructions on page #23 for checking these pressures.
Tubinq size Maximum run
3/8" t.D. 10'
112" t.D 70'.
518" l.D. 100'
3t4" LD. 125',
Furnoce
136.000 BTUlhr Un
30.000 BTUlhr'Figure 9
Gos Me ter
SOULTION TO EXAMPLE
(1) Maximum demand for outlet "A" 30 CFH
Maximum demand for outlet "8" 25 CFH 'Maximum demand for outlet "C" 75 CFH
Maximum demand for outlet "D" 136 CFH
c Ronqg "
75,0-00 BIUU f," scalE r=s
l0'
5',
Gos Dryer
25,000 BTU,zhr
TOTAL DEMAND 266 CFH
(2) The length of pipe from the gas meter to the most remote outlet (outlet "A") is 60'.
THIS IS THE ONLY DISTANCE USED.
(3) Using horizontal line marked 60', outlet "A" supplying 30 cubic feet an hour requires % inch pipe.
Outlet "B'supplying 25 cubic feet an hour requires % inch pipe. Section 1 supplying outlets "A" & "B',
55 cubic feet an hour requires % inch pipe.
Page 14
F) SECURE THE MILLIVOLT BOARD. See Figures 10A & 108.
NOTE: The unit is equipped with the millivolt board & burner/cover assembly already in
position. The millivolt board must be secured in place using the nuts included in the
components packet. Follow instructions 'INSTALLING THE BOARD'on page #16 to properly
secure the board and burner/cover assembly in place. Followthese procedures should the
millivolt board need replacing or is removed for seruicing.
o
MILLIVOLT BOARD REMOVAL. See
figures 10A & 108
1. Shut off the gas supply at the manual
shut-off valve.
2. Disconnect gas line flex tube from the
manual shut-off valve.
3. Disconnect any wall switch, remote
control or thermostat from the valve.
4. Remove the logs from the unit.
5. Loosen and remove the (2) 1/4" nuts
securing the bumer tube & bumer cover
assembly and remove.
Figure l0A
6. Loosen and remove the (8) 1/a" nuts and, while grasping the board, gently lift it off the (8)bolts
and remove from the unit.
BURNER IUBE MUST BE
SECURE BURNER
TWO 1/4" NUTS
SECURE MILIIVOLT BOARD
WTH EIGHT 1/4 NUTS
Figure 108
INSTALLING THE BOARD.
NOTE: The millivolt board is fitted with a gasket to seal the millivolt board. Make certain this gasket is properly
placed around the opening before installing the regulator board.
Attach the 1/4'nuts (included with the board assembly) and tighten.
place the bumer tube / cover assembly onto the board, properly seating the bumer tube over the orifice and
aligning the slots in the board to the studs in the cover. Secure with the (2) 1/4' nuts.
Connect the flexible gas line to the manual shut-off valve.
Reconnect any remote, wall switch or thermostat.
Replace the logs as described in section'G'.
c) #932 DV LOG INSTALLATION. See Figure 11A & 118, page 17.
2.
3.
4.
o.
This#932-500 logsetincludes: (1) A? loS
(1)'AG'log
(1)'AH' log
-m
Figure 11A
NOTE: THE 'AD', 'AG', & 'AH' LOGS HAVE ALIGNMENT HOLES INCORPORATED INTO THE
BOTTOM AND SHOULD BE PLACED ONTOTHE CORRESPONDING PINS IN THE BURNER
COVER.
(1) Al'los (1)'AJ'log
(2)'M'logs (1)'G'log
(1)'C' log
AJ
1. Grasp the board with both hands and place into the unit, lining up the eight 1/4" holes.
CAUTION: Before securing the board into place make sure that all of the wires (attached under the
board) are clear and unobstructed.
IMPORTANT: CHECK ALL CONNECTIONS WHETHER FIELD OR FACTORY MADE FOR LEAKS.
Page 16
1.
z.
3.
4.
Place the 'Al' log onto the center of the bumer cover aligning the curved left end to the curve on the bumer cover
and centering the log between the front and back slots. Press firmly onto the pins.
Place the 'AD', 'AG', & 'AH' logs into position on the bumer cover aligning the holes in the bottom of the logs to the
conesponding pins in the bumer cover.
Position top logs'M' and 'C' onto the previously positioned logs as shown'.
Position the 'AJ' log behind the log grate and set the 'G' log onto the'AJ' log..
*Refer to completed log set diagram below.
Figure 118
#936 DV LOG INSTALLATION. See Figures 11C & 11D, page 18.
This f1936-508 log set includes:
(1) XAH - Log (1) AP - Log (1) J - Log (2 pc.)
(1)AC-Log (1)c-Log (1)L-Log
(1)Ao-Log (1)G-Log (1)N-Log
Figure 11G
Installed #932 DV Log Set
Page 17
Rbfening to figures 1lC & 11D:
NOTE: THE 'N', 'L', AND'XAH' LOGS HAVE ALIGNMENT HOLES INCORPORATED INTO THE BOTTOM AND
SHOULD BE PLACED ONTO THE CORRESPONDING PINS IN THE BURNER COVER.
Refening to diagrams 1lC & 11D:
1. Place the 2 pc. 'J' log onto the center of the bumer cover aligning the curved left end to the curve on the bumer cover and
cenlering the log between the front and back slots. Press firmly onto the pins.
2. Place the 'N', 'L and 'MH' logs into position on the bumer cover aligning the holes in the bottom of the logs to the mnesponding
pins in the bumer cover.
Position top logs 'AO', 'C', and 'AP'onto the previously positioned logs as shown'.
Position the AG' log behind the log grate and set the 'G' log onto the AC' log'as shown.
ATTENTION HOMEOWNER / INSTALLER:
TO ACHEIVE OPTIMUM GLOW AND FLAME APPEARANCE, IT MAY BE NECESSARY TO SLIGHTLY ADJUST THE VENTURI
SHUTTER POSITION AND/OR THE LOG POSITIONS,
'Refu to the completed bg set diagnn, frgure 11D.
Figure 11D
4.
lnstalled #936 DV Log Set
INITIAL BURI{ PERIOD
Due to the makeup of the ceramic, logs & fiber refractory brick panels, the curing process may take up to 4 hours of
bum time. During this period, the logs and refractory will discolor but will retum to their true color once the curing
process is complete. Do not bum lhis fireplace without the glass propedy in place.
*MAKE SURE THE HOMEOWNER ISAWARE OF THIS*
Pee 18
H) THERMOSTAT-WALL SWITCH - REMOTE INSTALLATION (optional). See Figure 12 & 13. ' ,
CAUTION: DO NOT connect high voltage (115 V) wire to the switch.
v
1. lf desired, a thermostat, wall switch c[ remote
control unit may be used to tum the unit off and on.
Onlv one of these mav be installed. Follow
instructions included with each kit.
NOTE: InsmlumoN oF A THERToSTAT oR wALL
SWITCH SHOULD ONLY BE DONE BY A QUALIFIED
INSTALLER.
2. Run low-voltage (thermosta$ wire from the on/off
switch, to the desired location of the thermostat or wall
switch. Do not run wire more than 30'.
NOTE: lf too heavy of wire is used or run more than
30', the electicity generated by the unifs generator will
not be sufficient to make the regulator work proprly.
IMPORTANT: No high voltage (115v) is required to
operate any ofthese systems.
The on/off rocker switch on the millivolt
board must be in the 'off position if any of
the above systems are Installed on the
unlt.
Note: The fireplace must be turned 'on'and 'ofP by the same method. For
example: lf the fireplace is turned 'on' by
the remote, it must be turned 'off by the
remote.Remote Control Wldng Diagram
Flgure 13
Flgure 12
Page 19
t, r)COMPLETE THE INSTALLATION
l. Gomplete the fireplace walls, and the unit
facing.
CAUTION: Tne SURNOUNDING WOOD CHASE
OF THE OUTSIDE WALL MUST BE INSULATED
TO PREI/ENT COLD AIR FROM ENTERING THE
ROOM.
2, TH]S STEP SHOULD ONLY BE DONE BY A
QUALIFIED INSTALLER OR SERVICE TEGHICIAN:
a) Perform lighting and shutdown procedures
as described on page #21 . This should be done
prior to replacing the glass so that any necessary
adjustments can be made and proper operation
verified.
3. Replace the glass. Referalso to Figure 1, pg.4.
A) Align the slots in the top of the glass
assembly over the tabs on the fireplace.
B) Place the glass assembly so it is flush with
the front of the fireplace front.C) Secure the assembly to the fireplace by
pushing the two spring loaded handles (located
under the firebox) back, locking them into position.
WARNING: DO NOT OPERATE THIS FIREPI-ACE
WITH THE GLASS ASSEiIBLY REMOVED,
CRACKED 0R BROKEN. Replacement of the glass
assembly should be done by a licensed or qualified
sen rce
4. Upp*Grtil-Replace
A) Line the rods of the grill up with the upper
holes.B) Place the mds in the holes and push up until
the bottoms of the rods dear the glass frame.C) Place the bottom of the rods into the lower
holes and release. The grill will set down into
place.
Remove:
A) Lift the upper grill up far enough to clear the
bottom holes and pull bottom of grill out.
Lower grill - See Figure 14
Remove:
Remove the 1/4" nuts (B) from the lowergrill
assembly.
Pull the entire grill assembly out of the
hinges.
R+attach the 1/4" nuts (B).
Replace:
Remove the 1/4" nuts (B)from the lowergrill
assembly.
Slip the bolt through the hinge (A).
R+attach the 1/4'nut (B).
Repeat A" through 'C' for the remaining
hinge.
The gdll is now in place. The grill may be
lowered for lighting purposes, etc.
Figure 14
A)
B)
c)
A)
B)
c)
D)
Page 20
J) LIGHTING AND SHUTDOWN. See Figure 15.
NOTE: Prior to lighting, check all fittings for leakage. This is accomplished by applying soapy water on all connections
made. lf there is any leakage, bubbles will appear at the point of connection. lf bubbles orcur, tighten the fittings until
the bubbles no longer appear.
IMPORTANT: TEST ALL CONNECTIONS WHETHER FIELD 0R FACTORY MADE.
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of % psi.
NOTE: The appliance must be isolated from the gas supply piping system by dosing its individual manual shut off valve
during any pressure testing of the gas line at test pressures equal to or less than 1/2 psig (3.5 kPa).
Pressure check taps for the manifold (outgoing) and inlet (incoming) pressures are located in front of the gas valve. The
top pressure tap is the manifold pressure and the bottom pressure tap is the incoming pressure. Follow instructions on
page #23 for check these pressures.
N0TE: Read 1-8 before lighting the unit for the first time.
1 . Open the lower grill by grasping the center of the top louver, and pull out and down.
2. Set the thermostat, if used, to the lowest setting
3. Tum off all electricpowertotheappliance.
4. Push in control knob (A)slightly and tum clockwise \ to "OFF"
Gas control knob
shown in'on'position
NOTE: Knob cannot be tumed from "PILOT" to "Off' unless knob is pushed in slightly. Do not force.
5. Wait five (5) minutes to clear out any gas. lf you then smell gas, STOP!
this installation manual. lf you don't smell gas, go to the next step.
Follow the safety information on page 2 of
6. Find the pilot - follow metal tube from gas control. The pilot is behind the bumer tube.
7. Tum the black knob on gas control counterclockwise r' to "PILOT".
8. Push in the black control knob all the way and hold in. Press the RED igniter button (C). The pilot will generally light
with two or three pushes on the igniter. Hold the knob in for about one (1) minute after the pilot is lit. Release knob and
it will pop back up. Pilot should remain lit. lf it goes out, repeat steps 4 through 8.
' lf knob does not pop up when released, stop and immediately call your service
technician or gas supplier.
' ll the pilot will not stay lit afier several tries, tum the gas control knob to "OFF" and call
your service technician or gas supplier.
9. Tum gas control knob munterclockwise y'to "ON".
10. Flip the on/off switch (B) to the "on' position, the red is expsed.
11. Setthermostat, if used, to desired setting.
Page 2'l
l'
NOTE: When the unit is initially lit, condensation will appear on the glass, this is normal in all gas fireplaces, and will
disappear in one to three minutes.
12. lf you wish to tum the bumer off, flip the on/off switch. lf a wall switch has been installed, simply tum it off. lf a
thermostat has been installed, simply adjust temperature setting.
NOTE: The pilot will stay lit.
13. To tum off the pilot, push in and turn the knob to the "off" position.
Ftc. 15
NOTE: A PAINT SMELLWILL OCCUR DURING THE FIRST FEW HOURS OF BURNING. lT lS
RECOMMENDED TO LEAVE THE FAN OFF DURING THIS PERIOD AS THIS WILL SPEED UP
THE PAINT CURING PROCESS.
NOTE: Ghildren and adults should be alerted to the hazards of high surface temperature and should stay away
to avoid bums or clothing ignition. Young children should be carefully supervised when they are in the same
room as the appliance.
Glothing or other flammable material should not be placed on or near the appliance.
INITIAL BURI{ PERIOD
DUE TO THE MAKEUP OF THE CERAITIIC LOGS & REFRACTORY, THE CURING PROCESS IIAY TAKE UP TO 4 HOURS OF
BURN TIIIE. DURII{G THIS PERIOD, THE LOGS & REFMCTORY WILL DISCOLOR. ONCE THE CURING PROCESS IS
COMPLETE. DO NOT BURTI THIS FIREPI.ACE WITHOUT THE GLASS PROPERLY I}I PI.ACE.
*MAKE SURE THE HOMEOWTIER IS AWARE OF THIS'T
PgeD
1.
2.
3.
4.
5.
PRESSURE TESTING
MANIFOLD & INLET PRESSURE
IMPORTANT NOTICE: A pressure check tap for both the manifold (outgolng) and Inlet (incoming) pressure has
been Incorporated into the valve by Robertshaw. The top pressure tap is the manifold pressure and the bottom
pressure tap measures the incomlng pressure. Follow the instructions below for proper pressure testing
TO CHECK THE MANIFOLD PRESSURE:
1. Light pilot .
2. Loosen the manifold pressure tap [C] by tuming the screw counter-clockwise.
3. Attach manometer to pressure tap using a 5/16' l.D. hose [E].
4. Tum black control knob [A] to the 'on' position.
5. Tum the bumer on by depressing the rocker switch [B] to expose the 'red' and note manometer reading.
5. Tum the rocker switch [B] to the 'offl position.
6. Disconnect manometer hose and tighten screw (clockwise).
Screw should be snug, do not over tighten.
7. Attach manometer to manifold pressure tap to veriry that it is completely sealed.
Manometer should read no pressure when the rocker switch is tumed on..
NOTE: lf manifold pressure reading is within the normal range, an incoming pressure check is not necessary. A too high
or too low pressure reading warrants an inlet (incoming) gas pressure check.
TO CHECK THE INLET PRESSURE:
Loosen Inlet pressure tap screw [D] by tuming screw counter-clockwise.
Attach manometer using a 5/16'l.D. hose [E].
Light the pilot.
Tum the black control knob [A] to the 'on' position. (Bumer should not come on) and note manomoeter reading.
Tum the rocker switch [B] to the 'on' position and check the pressure to ensure that it stays near the maximum inlet
pressure.
6. Tum the rocker switch [B] to the 'off position.
7. Tum the pilot to the 'off position.
8. Disconnect hose and tighten screw (clockwise). Screw should be snug, do not over tighten.
9. Relight pilot and tum the conkol knob [A] to the 'on' position. Attach manometer to the inlet pressure tap to verifo that
it is completely sealed. Manometer should read no pressure.
NOTE: lf tnlet pressure reading is too high or too low, contact the gas company. Only a qualified gas service technician
should adjust the incoming gas pressure.
GAUflON: A LOW PRESSURE READING CAN CAUSE DELAYED rcNmON.
o
FIGURE.16
Page 23
K).t MAINTENANCE REQUIREMENTS
1. The appliance should be inspected at least once a
year by a professional service person.
NOTE: INSTALI-ATION AND REPAIR SHOULD BE
DONE ONLY BY A QUALIFIED SERVICE PERSON.
THE APPLIANCE SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BYA QUALIFIED
SERVICE PERSON. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE LINT
FROM CARPETING, BEDDING MATERIALS, ETC, IT
IS IMPERATIVE THAT CONTROL COMPARTMENTS,
BURNERS AND CIRCULATION AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
2. The compartment below the firebox (behind the
lower grill) must be cleaned at least once a year, more
frequent cleaning may be required due to excessive lint
ftom carpeting, bedding materials, or other fibrous
materials. lt is imperative that the bumer be cleaned
once a year.
FAN
The fan should be disconnected from electrical cunent,
and cleaned (vacuumed) every six months. The
bearings are sealed and require no oiling.
VENT SYSTEM
Annual examination of the venting system by a qualified
agency is required.
1. Remove the glass on the front of the unit.
2. For easier access, remove the logs.
3. Cover the millivolt board system.
4. Loosen the screws securing the baffle at the top of
the firebox and remove the baffle.
5. Examine proper sealing of the vent system.
6. Replace the baffle and secure the nuts.
7. Replace the logs, glass and upper grill.
IMPORTANT: ANY SAFETY SCREEN OR GUARD
REMOVED FOR SERVICING MUST BE REPLACED
PRTOR TO OPERATING THE APPLIANCE
CAUTION: LABEL ALL WIRES PRIOR T0
DISCONNECTION WHEN SERVIC]NG CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERAT]ON AFTER SERVICING.
MILLIVOLT BOARD SYSTEM
1. Annual cleaning of the burner is required. The
bumer tube / cover may be removed for easier access.
2. Remove the logs.
3. Remove the bumer tube i cover by loosening the two
nuts securing it on each side of the bumer cover.
4. Visually check for blocked port holes, especially near
the pilot. Blocked port holes may cause delayed
ignition.
5. Visually check the pilot light and bumer when they
are buming. See Figures above and below. The
flames should be steady, not lifting or floating.
GLASS CLEANING & REPLACEMENT . Clean glass only when cool and only with non-
abrasive cleansers.. Do nof op€rate this fireplace with the glass/frame
assembly remove, cracked or broken.
The glassfframe assembly, Paft#932407 (Model
#932) or#936407 (Model #936) shall only be
replaced as a complete unil as supplied by
Hussong Mfg. Co., Inc.
Replacement of the glass & gasket assembly,
Part #70S08T - Model #932 or Part #70G07T -
Model#936, musl only be performed by a licensed
or qualified service person. DO NOT
SUBSTITUTE MATERIALS.
Do not strike or slam glass door assembly.
CAUTION: KEEP THE APPLIANCE AREA CLEAR OF
COMBUSTIBLE MATERIALS, SUCH AS GASOLINE
AND OTHER FLAMTTIABLE VAPORS AND LIQUIDS.
ror t-1 \d i-4,\#c g
L-./
\,,-\
Bumer Orificel)ll \-/Pilot
P?q,e24
'l L) TROUBLE SHOOTTNG GUIDE
NOTE: The millivolt board includes the following items: Valve, generator, pilot assembly, piezo, electrode, rocker
switch, bumer, orifice and orifice holder. lf any of these items are defective, contact your dealer for the appropriate
repair / replacement procedures to follow.
WARNING: DO NOT ATTEMPT TO SERVICE THIS UNIT lF YOU ARE NOT A QUALIFIED INSTALLER 0R
REPAIRilAN.
1. lf the unit fails to ignite a qualified service person should check the unit installation.
2. lt is imperative that the control compartment, bumer and circulation air passageways of the unit be kept clean.
This is necessary to provide adEuate combustion and ventilation air.
3. All of the working parts of this unit can be removed at one time. Before removing millivolt board, check for loose
wires.
PROBLEITI CAUSE SOLUTION
No spark when piezo The nut which holds the piezo Tighten nut.
button is depressed in place is loose
Wie on ba* of piezo button Put wire back into place.
is loose or off
Wire from piezo to electode is Reconnecl wire.
loose at elecbode
Elec{rode moved out of position Realign electule with 1/8'
Pilotrvont light
space between it & the pilot.
Tum Gas On
Hold black control knob in
long enough to purye line.
Hold in longer
Hold button in longer to
heat thermocouple.
Check onnection on valve.
Pilot won't stay lit
Pilot hood misdirecting pilot flame Check pilot flame location.
from lhermocou ole.Flame must be buming on
genenator and thermocouple.
Gas shut off
Gas line not purged
Not holding black ontrol
knob in long enough.
Not holding black contrcl
knob in long enough.
Themocouple wire loose
at valve @nnec{ion.
Page 25
t
PROBLEM
Bumerwont light
Bumer wont stay lit
Flgure 17
CAUSE
Pilot not lit
Regulator valve not fumed 'on'.
Rocker switch not tumed
exposing the "Red'or bn'
indicator.
Rocker switch wire not connected
Genenator wires loose at
regulator terminals
Genenator wire gmunded out
due to pinching of wires
Wall switch, remote control
or thermostat not connec{ed
properly or tumed to wrong
setting. Seefigure 10.
Wall switch, thermostat wire too
thick or run more than 30 fi.
SOLUTION
Relight pilot
Tum valve to bn"
Press bottom ofswitch
Check wiring diagnm Figure
17 and ensure that all wires
are securc.
Reposition wire and Ughten
screws. See Figure 17 for
wiring instruclions.
Nub on millivolt board
may need loosening to
rcmove pinched wire.
Connecl properly or
disconnect and use on/off
switdr only.
Disconnecl wires from
valve. lf bumer stays lit
change location or use on/off
switch only.
ATTENTION HOMEOWNER / INSTALLER:
BLUE FLA*IES 1. SLIGHTLY CLOSING THE VENTURI SHUTTER ['AY BE NECESSARY IF FI.AMESARE BLUE.
AND/OR THIS IS LOCATED AT THE END OF THE BURNER TUBE WHERE IS IT POSITIONED OVER THE
LOW FLAiIES: ORIFICE. LOOSEN SET SCREW AND ADJUST. RETGHIEN SEt SCREW.
2. SLIGHTLY ADJUSTING LOG POSITIONS MAY BE NECESSARY TO ACHEIVE OPTIMUM GLOW &
FLAME APPEARANCE.
Page 26
Replacement parts are available through your local dealer.Gontact them for availability and pricing.
MILIIVOLT BOARD AND PARTS
932.400 tfl132 Millivolt Board - Natural Gas
932.f01 #932 [llllvolt Eoard - LP Gas-
936.0{10 #936 ]tlillivolt Eoard - Natural Gas 936.(ll #)36 ilillivolt Board - LP Gas 700{32 Ple:o lgnltor
700-{133 On/Off Toggle Switch 700{36 MillivoltGen€rator
700{t39 HirLo AdJustablo regulator (Natural Gas)
700-{140 HULo AdJustable regulator (LP Gas)
700-059 Th€mocouple(3o€ocond,
700{160 Pllot Tub€ with litting (valve to pilot}
700-203 Manual Shut off valve
932-135 Bumer Tube & Cov.r - lrodel #932 DV
936-135 Burner Tube & Cover - Model #936 DV
700-212 12" Flexibls Gas Lin€ - #932 gas lino conntction
700-213 18" Flexiblo Gas Line - #936 gas line connection
700-A24 3/8" Flexibls Gas Llne (valy. to bumer connoclion)
700-231 #936 Natural Gas orifice -f,|1
700-238 fi)32 Natural Gas oriflce - #38
700-249 #936 LP Gas orifice -#f9
700-2:t:l #932 LP Gas oriffce -#53
700-267 Natural Gas Pllot orifice
700-266 LP Gas Pilot orifice
700{155 PiloUGeneralorlThermocruploAssembly{al Gas
700{156 PiloUGenerator/ThermocoupleAasembly{PGas
OCK€31 Natural Gas Conversion Kit - #936 DV
OCK€38 Natural Gas Conve6lon Klt - #932 DV
OCKA4g LP Gas Conversion Kit -#936 Dv
OCKA53 LP Gas Conversion Kit -#932 DV
FAI{ . REPLACEi'ENT ONLY
932-028 #932 DV Fan Klt wlth Temp€raturs limit lwltch & 3pood control
600-l #936 DV Fan Kit with Tomp€ratur€ llmlt switch & speed control 4011 Limit Switch Assembly
600085 Spe€d Control
REMOTE CONTROLS / THERMOSTAT
79&1 Remote Control with thsrmostat 797-1 Remoto control
700038 Wall-mountThermostat
GI.ASS AND BRASS TRIU
932{107 11932 DV Replacment glass a$embly -
Includes 12'x27" glass, gaskot & arched frame
936{07 #136 DV Replacement glass asssmbly -
UPPER GRILLS
includes 17"x30'glass, gasket & arched frame 932-201
936-201
700{tET 12'r 2f Ghss with gasket - llodel#932 DV 932-218
700{l7T 17- x 30" Glass wlth gasket.llodel #936 Dv 936-218
302-112
500.0{14 1 1/8" Glass gagkot d adhoalve VF-201
500-932 Arched Fram€ Brass Trlm (2 pc.) -t932 DV
500-936 Arched Frame Erass Trlm (2 pc.) - #9i!6 DV
LOG SET
932-500 Log Set - #932 DV
936.fl18 Log Sst - #)36 DV
GRILL LOUVERS
VENT SYSTEMS
7/t5 Mfsc. 718 617 rl4'Llntel lron 78
932-080 Black Int€rlor Trim -#932 717
936{180 Black Interior Trim -#936 923€
932{181 Black Exterlor T.lm -#932 745060
936-081 Black Ext€rlor Trlm -#936
932-DOR Traditional Twin iresh Doors - Model #932 DV
936-DOR Tradltlonal Twln Mesh ooora - Model *936 Dv
*932 J#936 DY . US TTVSIALIJATOflS OrYtY
Revrsed 8Pg rYrYY.koryhaltcom
PageZT
Black Lowsr Grlll - rc32 DV
Black Lower Grill . #936 DV
Brass Lower Gdll - #932 DV
Bra$s Lower Gdll - *936 DV
Bras8 Accent Low€r Grill . *932 DV
Brass Accent Lowor Grlll - t936 Dv
8ra$ lower 27 1/2" (illodel *932 oV)
Brass lower 30 112" (Model #936 DV)
Black louvar 27 1/2" (Model il932 DV)
Black louver 30 1/2" (Model #936 DV)
Dlrsct Vont Klt (for tBrmlnatlons up to 4')
Dlroct Vont Kit (for t€rminatlons up to 8'
Diroct Vent Extonslon Klt (6' long)
Vlnyl Sldlng Protector
Oura-Vont Adaptor
Firestop
932-200
93&200
932-208
936-208
301-112
vF-200
LOWER GRILLS
500-an
5{'0-225
500-24
500-2€
Black Upper Grill - f!r32 DV
Black Upper Grlll - #936 DV
Brass Uppor Grlll - f932 DV
Brass Upper Grill - f930 DV
Braas Accent Upper Grill - #932 DV
Brass Accent Upper Grlll - #936 Dv
tlanuhctred by:
Hussag Xfg. Co., Inc #932 DV &
2U tndusbial Part DdYe
Lakef,eld, ilN 56150
This Umited 10 Year Warranty will not become effective
until the warranty registration form has been completed
and mailed to Hussong Manufrcturing Co., Inc., P.O. Box
577, takefield, MN 56150. This registration form must be
received within 30 days of installaUon. Failure to do so
may result in delayed warranty coverage and submission
of proof of purchase will be required.
Hussong Manufacturing Co., Inc. warranties to the
original purchaser of this Kory Heat Fireplace, that it is
free of defects in materials and workmanship at the time
of manufacture.
Subject to the following conditions & requirements,
Huslong Manufacturing Co., lnc. extends the following
limited warranty under normal use and service, with
respect to the Kozy Heat line of gas burning fireplaces.
KOZY HEAT
LIMTTED 10 YEAR WARRANTY
LIMTTATION OF LIABILITY
YEAR 1: Subject to the following conditions &
requirements listed below, within the first year from date
of purchase, Hussong ManuEcturing Co., Inc. shall, at its.
discretion, replace or repair any such defect in material or
workmanship, at Hussong Manufacturing co., Inc.'s
expense, including reasonable labor costs to repair or
replace the defective component, if a factory pre-
authorization is given for the repair.
YEARS 2 - 10: Subject to the following conditions &
requirements listed below, beginning with the first day of
the second year and continuing through the tenth year,
Hussong lvlanufacturing Co., Inc., will at its discretion,
provide repair or replacement parts at current wholesale
prices for any defect in material or workmanshiP of
components, including optional components and
accessories Hussong Manufach.rring Co., Inc. shall not be
responsible for any installation, labor, transportation or
other indirect costs.
o
To make a claim under this wananty, the purchas€r must
first contact the dealer/installer from whom the fireplace
was purchased.
This limited warranty will be void if the fireplace is not
installed by a qualified installer and according to the
installation insbuctions. Use of unauthorized components
will make this wananty null and void.
This limited warranty also is void if the fireplace is not
operated, at all times, according to the openting
insbuctions fumished.
This warranty is limited to defects in material and
workmanship. It does not apply to any product that has
been subject to negligence, misapplication, improper
installation. Prcducts made by other manuftchtres are NOT
covered by this Limited Waranty, regardless of whether
they were purchase with the fireplace or later added.
No p€rson is aufrorized to ertend the time of this warranty
or to accept on Hussong Manufacturing Co., Inc.'s behalf
any addifonal obligation of liability connectd with the unil
It is o(pressty agreed and understood that this warranty is
Hussong Manufacturing Co., Inc.'s sole obligation and
purchaser's exclusive remedy for defective fireplace
equipment. Hussong Manufacturing Co', Inc. shall not be
liable for any consequential, incidental or contingent
damages whatsoever. The foregoing warranty is exclusive
and in lieu of all other expressed wananties. Hussong
Manufacturing Co., Inc. shall not be held to implied
warranties, induding but not limited to the implied
warranties or merchantability and fitness for a particular
purpose. This warranty replaces all previous wananty
policies.
Some states do not allow the exclusion or limibtion of
incidental or consequential damages or lim'rtations on how
long an implied warranty lasts, so the above limita$ons or
exclusions may not apply to you. This warranty gives ylu
specific legal rights and you may also have other rights
which vary from sbte to state.
Hus$ng Manufacturing Co., Inc. reserves the right to make:
changei at any time, without notice, in design, mataial,
specifiotions and prices. Hussong Manufacturing €o-, Inc'
reserves the right to discontinue models and products.
l.
2.
3.
1.
5.
7.
R
WARRANW CONDmONS & REQUTREMENTS:
You are the originat purdlaser. This warranty is not Fanderable.
lnsbtlation of he fireplace is performed by a qualified indaller.
tnstaltation and operation mu* compty with installation and opeGtign instuctions.
Paint and glass gastets are covered for 30 days from date of purchase.
Components (induding gtass panels) broken, during shipping, careless handling of components, or defects resulting ftom improper
lnsUitation, misuse of-fre fireplace and componen6 are not covered under this wananty.
This warranty does not cover any part of the flreplace or any components whidl have been exposed to or submerged under water'
, - -
Hussong Manufacturing Co., Inc must be noufied by he dealer the fireplace was purdrased ftom or a qualined installer or seruce
tedrnician of the defecL
Annual service ofhe fireplace as required in Ure insbllation manual, is performed by a qualified instalter/service tednician'
(Copies of such seMce records may be required to daim a warranty')
All previotF warranty/service has been performed by a qualified installer or service tedlnician. (Copies of such seNice records may
''K o 0
Pl
z Y
Fire aces
AT
Life
JUNE 1998
E
For auality
LIFETIME WARRANTY
TIIIS UFErIME WARRANW COVERAGE WILL BE EXTENDED AS DESCRIBED BETOW PROVIDED AIL WARRANW
coNDmoNS AND REQUTREMENTS ARE MET AS OUTTINED IN THE 10 YEAR LIMITED WARRANTY POLICY.
UFETIME WARRANW COVERAGE
UFEnME WARMNTY IS EffENDED AS FOLLOWS: Hussong Manufacturing warranties to the original purchaser that the firebox, heat
exchanger, fiber logs, bumer tube and glass of this Kozy Heat fireplace will not be defective in material or workmanship under normal
use andservice fot ai tong as you own this product. If any of these components fail due to defects in material or workmanship under
normal use and service, Hussong Manufacturing Co., Inc. will, at its sole discretion, repair or replace the defective component. This
UFEnME WARMNTY d-oes not cover any installation, labor, transportation or other indirect cosLs arising from defective components.
LIMITATION OF LIABILIW
This Lifetime warranty will be void if the fireplaie is not
insbtled by a qualified installer and according to the
insbltation insrudions. Use of unauthorized components will
make this wananty nutl and void. Thislifetimewarranty also is
void if the ftreplace is not operated, at all times, according to
the operating insbuctions fumished.Thiswaranty is limited to
defects in material and workmanship of components
specified. It does not apply to any product that has been
subject to negligence, misapplication, improper installation.
No person is authorized to extend the Ume of this Lifetime
warranty or to accept on Hussong Manufacturing Co., lnc.3
behalf any additional obligation of liability connected with the
unit.
Hussong Manufactuiing Co,, Inc. may fully dixharge all
obligations with respect to this Lifetime warnnty by refunding
the wholesale price of the defective componen(s).
It is expressly agreed and understood that this Lifetime
warranty is Hussong Manufacturing C-o., Inc.3 sole obligation
and original purchaser's exclusive remedy for defective
fireplace equipment. Hus$ng Manufacturing C-o., Inc, shall
not be liable for any consequential, incidental or contingent
damages whatsoever other than those incured by Hussong
Manufacturing Co., Inc. to repair or replace the defecb've
component. The foregoing wananty is o<clusive and in lieu
of all other expressed wananties. Hussong Manufacturing
Co., Inc. shall not be held to implied wananties, induding but
not limited to the implied warranties or merchantability and
fitness for a particular purpose. This lifetime warranty
replaces all previous lifetime warranty policies.
Hussong Manufacturing Co., Inc. reserves the right to make
changes at any time, without notice, in design, material,
specifications and prices. Hussong Manufacturing Co., Inc.
reserves the right to discontinue models and prcducts.
Grta!$ @rto !!a)
TO ACTMTE THrS UFETTME WARRANTY COVERAGE, THrS REGISTRATTON CARD MUST BE COMPLETED AND MATLED WITH YOUR
COMPLETED 10 YEAR UMITED WARRANW FORM WITHIN 30 DAYS OF INSTALLATION.
PURCHASERS NAME:INSTALLATION DATE:
MODEL#:
TELEPHOI{E #
TELEPHONE f
I ooo*.*,
INSTALLER NAHE:
ADDRESS:
SERHL #:
a
TOWN OF VAIL DEPARTMENT OF COMMTJNITY DEVELOPMENT
75 S. FRONTAGE ROAD
vAtL, co 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
PLUMBING PERMIT Permit #: P02-0088
Job Address: 1476 WESTHAVEN DR VAIL Status . . . : ISSUED
Location.....: COLD STREAM CONDO #15 Applied. . : 07118/2002
Parcel No...: 210312108015 lssued. . : 07/23/2002
ProjectNo : Expires. .: 0l/19/2003
owNER FELDMAN, AARON 07/L8/2O02 phone:
4445 EASTGATE MALI-, STE 4OO
SAI{ DIEGO CA
9212L
L,icense;
coMrRAcToR cor,oRADo wEsT PLI'MBTNG & HE;AOT/L8/2OO2 Phone: 303-926-4353
P.O. BOX 1
WOLCOTT, CO
81655
License: 2t8-P
APPITTCA$r COT,ORjADO WEST PLI,I{BrNG & HE;A07/L8/2002 Phone: 303-926-4353
P.O. BOX 1
WOLCOTT, CO
81555
Iricense : 21,8 -P
Desciption: ROUGH IN BATH,MOVE SHOWER IN LL BATH, REMOVE 7 LAVS RELACE
w.c.
Valuation: $4,500.00
Fireplace tnformation: Restricted: ?? # ofGas Appliances: ?? # ofGas Logs: ?? # of Wood Pallet: ??
** ** * + +*at+aa+ tal
Plumbing-> g?5 . oo Restuannt Plan Review-> So. oo Total Calculated Fees-> $96 . ?5
Plan Check-> $18.?5 DRB Fee..-_------> $0.00 Additional Fees > $0.00
tnvestigation-> $0 . oo TOTAL FFES------> $96 . ?5 Total Permit Fee------> 995 . 7s
Will Call-> $3.00 Payments-> S95.?s
BAI,ANCE DUE-----> 50.00
*rta arl * *** * l l l a'it+Iten: 05100 BUII-'DING DEPARTMENT
o7/L8/2oo2 DE Action: AP
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPL,IAI{CE'
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, Uniform Building Code and other ordinances oftlre Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MN)E TWENTY.FIOUR HOURS IN ADVAT.ICE BY AT 479-2l3t OR AT OUR OFFICE FROM 8:ffi AM - 5 PM.
WNERORCONTRACTORFOR ANDOWNET
| + + + + t ta +* * + * t ** * {.* * 't +1. * * * l' * l' * '} ** ** lt+ + ++* + + * *** * * * ** * *'} * ** * * ** *** t + ++ + t l' ** * * * * * * * * * * ir*{. +* *t
TOWN OF VAIL, COLORADO Starement
* * ****l ft + + * + * *** ** * ** ** ****** * + ** +t ++ +++ | | f*+ **a * ++ * ** * *** ra* ***i ++*+ + + t *'t * ++ * + + ft t *** **f*+
staEement Number: R000002780 Amount: $96.75 07/23/2002L2244 PY!
Palment Method: Check Init: LC
Notation: #9I7r/Colo
west p&H
Permit No3 P02-0088 Tlrl)e: PLT MBING PERMIT
Parcel No: 210312108 015
Site Address: 1476 WESTHAVEN DR VAIIJ
Location: COIJD STREAM CONDO #15
Total FeeE: $96.75
This Pa)rment: $95.75 Total. ALL Pmtss $95.75
Balance: $0.00
*'**i**********+*ti**********'I'|{.'lr*****++************:1.*'}i'}**++t*+++t*t*'l++l * * * t* * * * * * * I * *** ** *
ACCOI.JNTITEM LIST:
Account Code Descriotion Cunrent Pmts
PF OO1OOOO31123OO PLAN CHECK FEES 18.75
PP OO1OOOO31112OO PLUI'IB]NG PERMIT FEES 75.00
lic OO1OOOO31128OO WILL CALL INSPECTION FEE 3.OO
u'Iainl Perinit #:
mvnoF
75 s.
Vail, Colorado
g Permit #:
7 o- 47 9 - 2149 (InsPections)
PLETE VALUITION FOR PLUMBING PERMIT (LAbOT & MAICTiAIS)
Contact and Ph-one #'s:
4)t 13t 76 1353 Town of Vail Reg. No,:
stg P
Plumbing Contractor:
,oo?ADu l^resi P+H tvq.l
PLUMBING: $
fnnfet*Assessors Office at 970-328-864O or visi!
lob Name: Cot\STpeA44 Job {d{ress: 1 5i C.4 S f ee 4 v-l
trM lJt-f lldltlnt hDiurt- ,
Legal Description {t{I ts Block:Filine: pn496 E Subdivision: CoL\ STneAtu\ UPD
g,
"rt-" -a ^, !l ::Ensineer: @ llPh"L
Rouatlru L.L, Bert+, , f\oVe 5ho-e,c- lN Ll 6ATh t R.t%
WorkClass: New() Addition( ) Alteration0() Repair( ) other( )
ryp" or eldg., single-family t I oro"t( ) Multi-familY 0Q commercial ( ) Restaurant ( ) other ( )
:r ': := :
No-f f*i.ting Dwelling Unlts in this building: 3 't ll ruo. of Accommodation Units in this building: 4
rtl N"l_l_
'
for Parcel #
**t ************************************FOR OFFICE USE ONLY*************************************
LrJ oL fr lNvtlitrNcti' '
53SO 6c72int'E frl/l=-
lPbtfrv'+PIul.S ilV. 1b)).c)'
F/everyone/forms/Plmbperm
.n/$$,A./
t4r^P t^J-^
-t- I E\- T a efcg$$Jff
ffi i}lfrir.*topmentDepartnentRusse'Fone*Direcror,
er.Jp{
Check all that appfies.
1. !T{t O.p.rrn n(s)did you conhct?
Euilding _ Environmenhl=== Housing_ Admin Plannino _Dpg _
2. Was your inital conbct witr our sff innnedide
no one avdlable___?
3.
ff lou yere required b rrvait how long was it bebre ygu were helped?
4. lvas yoyr project revieived on a timety basis? yes / No lf no, why not?_
5. Was tris your first lime b fle a DRB app_ pEC app_Bldg Permit_ IrUA
6. nleage 3te fte performance of tre sffperson who asssbd you:54g2tName:
slow_or
t.
8.
(knowtedge; responsiveneili66Ei
Overallefiectiveness oftre FrontService Counter. i 4 3 2
What is tre best time of day for you to use fie Front Service Counter?
9- Any commenb you have which umuld allow us to beterserve you
It*.g fur taking tre tme to compteb thr.s survey. We are commifted b improving our semce.
Design Review Board
ACTION FORM
Department of Community Development
75 South Frontage Road, Vail, Colorado 81657
tel: 970.479.2139 faxz 970.479.2452
web: www.ci.vail.co.us
Proiect Name: Wolf Residence DRB Number: DRB020206
Project llescrlption:
Add window
Participants:
OWNER Andrew H Wolf O7lO2l2OO2 Phonei 317-252-446I
Wolf Investments LLC
5350 N Keystone Ave
Indianapolis,IN 216220
License:
APPUCANT SRE Builders Inc 0710212002 Phone: 376-1536
Stephen Elicker
POB 6376
Vail, CO 81558
License:
PrcjectAddress: L476 WESTHAVEN DRVAIL Location: Unit 15 kitchen area
Legal Description: Lot:53 Block: Subdlvlsion: COLDSTREAM CONDO
ParcelNumber: 210312108015
Comments: SeeConditions
lll ( ots\,*.-zr. Lr:nlo5
BOARD/STAFF ACTION
MoUon By: Action: STAFFAPR
Second By:Vote: DateofApprovaa. 07lO3l2OO2
CondiUons:
Cond: 8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and/or the appropriate review committee(s).
Cond: 0
(PI-AN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond: CON0005390
New window to match existing windows
Cond: CON0005391
Approved per plans submitted
Planner: Allison Ochs DRB Fee Paid: i2SO.OO
ffi
TOt 1t\r 0r yAItP
Application for Design Review
DeDartment of Community Development
ZS Soutr Frontage Road, Vail, Colorado 81657
te| 970.479'2139 fax: 970'479'2452
web: www.ci.vail'co'us
General Information:
Al|projectsrequiringdesignreviewmustreceiveapprova|priortosubmittingabui|dingpermitapp|ication.P|ease
refer to the submittal requirements for the particular approval that is requested. An application for Design Review
cannot be accepted until all required information is received by the community Development Department' The
pqect may also need to Ue'reirieweO by the Town Council anb/or the Planning and Environmental Commission'
Design review approva| |apses un|ess a bui|ding p...it i",i'.u.d and c,onstruction commences within
one year of the aPProval.
Description of the Request:
t'2
l-oc"tion of the Proposal: Lot: 5J Block:- subdivision:
physical Address: ltr?( . L'z +l,Jt,gf , ]$! = uo" '- 6l '' " ' t '',." "'
;;"", ;"., fir,r, ,f ft, ( nt,?€"#L2&,3f".Assessor at e70-328-8640 for parcer no.)
Zoning3
Name(s) of owner(s):
Mailing Address:
Phone:
_--Owner(s) Signature(s):
NameorApprrun, S(€ 6tc.'ld'ors, Int S+hon [/'n'/t'
Mailing Address:phone:(4 7(') *3 7(. -, \ -)\,
$50 Plus $1.00 per square foot of total sign area'
No Fee
$650 For construction of a new building or demo/rebuild'
;300 For an addition where square f-ootage is added to any residential or
-4-::ommercial buitdinj (includes 250 additions & interior conversions).
KEzW-A; tinor. cn"neesio buildinss u$..:lt" itqr.-olements'
such as'
rerootrng, pu,nling, windofr additions' landscaping' fences and
retaining walls, etc'
$20 For minor chinges to buildings and. site improvements' sucn as'
rerooflng, puinling; *indo'i udoitions' landscaping' fences and
retaining walls, etc'
$20 foi revlions to plans already approved by Planning staff or the
Design Review Board'
No Fee
E-mail Address:
Type of Review and Fee:
n Signs
El Conceptual Review
tr New Construction
tr Addition
.( uinor Alteration ' (multi-familY/commercial)
tr Minor Alteration
(single-familY/duPlex)
Cl Changes to Approved Plans
n Separation Request
.-\44
q6i
For Office UPe OnlY:F;;^|;;--JAI-- cnecuno' //S/ BJ:
'g;/27)?,O82 99! 5E rrsOBE H.ltsIN AEv rlr ,^r!
Appllcrtlon for Daelgn Revlew
,,3$#I_*r.Hl[vj'liims"
wlbi wm .d$ll.e.ul
ffitrSffi'ffiHn rrvrrt murt rdvc 1y:*lgf.nf#[X.*f ilffi5.?H{'; ffi
#,trss,it'w4$fiffil{ffi ,.ffi fr 'ffi gJffi ffi 39ffi"T!"!if.xT*i,i.fl Im ierr ot tr rpFrovrl,
DnstFdort of $. llcqu-tt
" r.oiidon ot itr'c propor.tr totjS-Blo*:-
Fht lc.l Atldnrrt
Prtul ilo"!
Subdlvbloni , '---------
Arc!$or rt 970-328'8640 for psrcel m')
lcnlnol t..,/cr,+a.rvsKrmsnrls-j C_Aoofara^,'q, e.Jorf
trrm(t) otOrrnc(.)l
ilrlllnt Adhtrl
o,'nrG(N) ilinatur(r)
x.nta ol APlkrritt
lldling Addrrilt
Slso c.t9Ttiltt rr/€zvOnpraFovS
l.?4i ZSV t++(4
Frnrtllddlrl
tlpce nrvlcwnrdF|.|
i gtgnl
C cooccgttr;Rcriryi
tr ilil CgnmJdon tr Addllort
ffiHm*nHmmanrrr)
d Mhor $tErldon
(ting|elrtrlV/ft913()
C Chln{.| b APnrwrd Phnr
6 Sroerrtm lrourc
ilg 31.00 9cr rqurrc ftd ol t6l EIgn u'r'
For can$udon ol r ncn uuildlng or dcrm/nhdC'
s'*#$Jl"ir.mu#6'6Eiqipl"t'iiiiltiti. d buftnng! rnd tt' lmDmvlmqrq tugn $'- --iJ#i,-iirfr;g, wlndovr rdrfirnr''lmdrcrph9' ftnor rrl
ftblnlnl $tlE cta
#fi#A;ng.li F bululngand dtt imerevrmrnB sflTl -.;dd;;"p.liittg,' wrncal rddttlono lcndtcDlngt Lneg r^u
150
N0 Frr
t650
t3o0
sz30
sz0
r€blnilg wllt, ttg .ro Fof G{ldcnt !o Ernr ellcrdY rpprcrntl by Pbnnlnt 5ril 0r $'
OaCgn k{'hvr BoNrd'
No Fet
i[ niO,- Chcck o:---
zs'4 te6z tgz Lrz 'l-3-'to:lA3H3 - l-loM - cns ].f U l9=Sl ZAgZ-8Z-Nnf
;t I
E I r
E F
E v
d o:;
S r)---] i;o:
oa ()t
dE ? 6,.|fl6g 56&
F88 p_3
6=E.t
8g
f,Ff
FF'
-
l
EEgi
ffiFi
wsr'L;gfiE
tsii.* !S
(- '-c:o)l TT rI t3
r,a
IL.'I:I:I
E
Fry
;=\J 0:)C)'t
(E0
?E vr-dg * oE
F-Y(b
p.,3
-oJ Po ;o d3
ffiT
E=E
a
.
I-;
I tD
ffiE Ie#rE
EJi.* H
IT rr
VAIL CASCADE
CONDOMTNIUMS
Iune24,2002
Town of Vail
Design Review Board
S. Frontage Rd
Vail, Colorado 81657
To Whom It May Concern:
The Coldstream Association approves the construction work that is being proposed by
Andrew Wolf, owner of Coldstream 15. That includes the addition of an exterior window
on the second level facing the west.
Sincere
Don Maclachlan
General Manager
1476 Westhar€n Drive . Vail, Colorado 8l 657
970.476,6106 , 8W.543.4801 . Fax97O,476.4946
+f***+a+t*++++**'t*'i++ar*+*f**r*++f*ar'i't*+*at**++{'r'}*++*'}**f++**r'}*t+**||*t***t*f+**t**t+t*r**
TOWNOFVAIL, COLORADO Statem€nt
*+***'if+**a*'talt** * * t***r **f+*r***l ** * *** | + ** * * +** **f* +** ****l*ar**+l****lr+**r**++rf+a++***ft
statement Nr:mber: R000002660 Amount: $250.00 o7/02/2oo2o4:05 PM
Payment Method: Check Init: iIAR
Notations 1451 SRE Builders fnc
Permit No: DRB0202o6 I)4re: DRB-Minor Alt, comm/ltulti
Parcel No: 210312108015
Site Address: 1475 I{ESTHAVEN DR VAIL
Location: Unit 15 kitchen area
Total Fees: $250. O0
This Palment,: $250.00 Total ALL Pmts: $250.00
Balance: $0.00
* + * *f**+***f + *{r* *ft *+ ***l t't **i$*:f a ** **tf* * r* ** * * | *l + a* *+ *t*+ * * **f*t +***aa*t**a*****++**f*** t*
ACCOUNT ITEM LIST:
Account Code Descr.iDtion Current Pmts
DR OO1OOOO3I122OO DESIGN REVIEI.I FEES 250.00