HomeMy WebLinkAboutE17-0039 load calcs.pdf Residential Standard Calculation 9/25/1997 Stone Residence
.bn.sako„ Version 2014
STEP 1 Article 220.42&220.52 Ameramex Electric LLC
sq.K • 4500 General Lighting load 13,500 VA P.O.Box 2155
2 Small Appliance 3,000 VA Eagle,Co 81631
1 Laundry circuit 1,500 VA 970-376-6455
Gen.Lgt,Sm App.&Laun. Load 18,000 VA 3/25/2017 11:21
3,000 VA @ 100%= 3,000 VA
15,000 VA @ 35%= 5,250 VA
VA @ 25%= VA
STEP 2 Article 220.50&220.51 CI General Lighting Demand Load 8,250 VA
Heat Pump w/Concurrent Supplementary Heating QTY
0 V I VA AHU 1 Select • VA Qty • Heating Load VA
HP 42 •I VA AHU 2 Select • VA Qtv • HP Load VA
{
HP#a • VA AHU 3 Select IF VA Qty V
HP#4 V> VA AHU 4 Select r►' VA QtY • Greater of Heat @ 100%vs.A=C @ 100% VA
VA AHU 5 Select V VA Qty •
STEP 3 Article 220.53 Appliance Demand Load 6,641 VA
GAS V 1 Water Heater VA
1.400 VA • 1 Refrigerator 1,400 VA Dryer Demand Load 5,000 VA
dUO VA V Freezer VA
1200 VA • 1 Dishwasher 1,200 VA Range Demand Load VA
1:127 VA •, 1 Disposal 1,127 VA
540 VA V 1 Range Hood 540 VA Service Demand 19,891 VA
1,400 VA • 1 Microwave 1,400 VA
U 1 440 VA • Central Vac VA Demand Load Li@ 208V,1ph 96 A
288 VA •' 1 Mini Refrig 288 VA
Li 400 VA V. Compactor VA Neutral Demand 88 A
L 12,000 VA v' Tankless heater VA
1.SOOVA • 1 Wine Cooler 1,500 VA
Min.Service Req. 100 A
U select w` Jacuzzi Tub VA
• select • Sprinkler VA
L select •! Well Pump VA
select • Fountain Pump VA
select • Elevator VA
Pool Equip.Panel VA 100%Demand
El 1400 Other load 1,400 VA Apply Demand
® Other load VA No Demand Total Appliance Load 8,855 VA
4 or more demand @ 75%plus 100%demand loads 6,641 VA
STEP 4 Article 220.54
Electric Clothes Dryers 5,000 VA
STEP 5 Article 220.55
Electric Ranges W Col C demand 0
or Number of appliances
Cooktop Col B demand
L]Check Box for Gas Range Cooktop Col B demand Use this area for your own notes
Oven(s) Col B demand
Oven(s) Col B demand
Number of appliances 0 Dem.Factor 0%
Cooktop&Oven Demand Load W
imp 1 jds(dtcomcast.net
»»»»»»»»»»»»»»»»»»»»»>««««««««««««««««««««««««<
Pool Panel Feeder Calculation (See Note) A B N Continuous Non-continuous
Continuous Motors 0 0 0 0 Motors Motors
Non-continuous 0 0 0 0 select •'L 240v select • [71240v
Spa heater 11 kVA 0 0 select • ❑ 240v select • L]240v
Pool heater 3.5 ton 0 0 select v Li 240v select •' ❑240v
Pool heater 5 ton 0 0 select •',Li 240v select • ❑240v
Pool Light select •'' 0 0 0 0 select V ❑ 240v select v ❑ 240v
Blower select • 0 Ea 240v 0 0 0
other load 0 LJ 240v 0 0 0 0.0 Motor Neutral Load
other load 0 [l 240v 0 0 0
0 Min.Copper Pool Feeder AWG A A A Max.Unbalanced Neutral Load
Minimum Panel Rating A Phase Amperes Neut.load
E -1 -G037