Loading...
HomeMy WebLinkAboutB18-0043_KRM Concrete Options_1541705807.pdf of OF p4, KRM CONSULTANTS . INC . STRUCTURAL ENGINEERING AND DESIGN € I or October 3, 2018 11/08/18 Dan Muller R.A.Nelson 51 Eagle Road#2 Avon, CO 81620 Re: 1290 Westhaven Remodel KRM Job# 1803-07 To Whom It May Concern, At the request of R.A. Nelson, the concrete slab-on-grade options below are provided for the garage storage area for the residence located at 1290 Westhaven Circle in Vail, Colorado. KRM Consultants, Inc. recommends the following concrete slab-on-grade options: • For concrete slab-on-grade with in-slab heat: 5" concrete slab on 4" clean gravel base on undisturbed grade or compacted structural fill per soils engineer. Reinforce slab with 6x6-W1.4xW 1.4 welded wire fabric throughout. Provide 11/"tooled control joints at 10'-0 maximum spacing each way; • For concrete slab-on-grade without in-slab heat: 4" concrete slab on 4"clean gravel base on undisturbed grade or compacted structural fill per soils engineer. Reinforce slab with 6x6-W 1.4xW 1.4 welded wire fabric throughout. Provide 1" tooled control joints at 10'-0 maximum spacing each way. This letter is not intended as a product or service warrantee. Please do not hesitate to contact us if you have any questions, or if we can be of further service. Sincerely, KRM Consultants, Inc. �+.�••+t`'moi\A Structural Engineering and Design. F®0 REG/8,S% ta Alp® 34167 ,0,(0, Schmi• , - Tim D. Henn j U!�lNJM. Project Engi er Principal Engineer P.O. Box 4572 • VAIL, CO 8165B • (970) 949-9391 • FAX 949-1577