Loading...
HomeMy WebLinkAboutB18-0507_Approved Documents_1542214820.pdf 75 South Frontage Road Construction 0West, TOWN OF VAIL B18-0507 Vail,CO 81657 Issued: 11/14/2018 TOWN OF VAIL „ Office:9 70.479.2139 Inspections: inspections@vailgov.com Property Information Address: 660 LIONSHEAD PL 109 (210107201037109)(210107201037) Unit#: 109 ParcelNumber: 21010 72010 37 LegalDescription: DESC: PHASE I Subdivision:LIONSQUARECONDO Unit:5 Contacts ContactType: Applicant Full Name: KatelynMcDonald Address: PO Box 5400 51 Eagle Road#2 Avon,CO 81620 Phone: 9709495152 ContactType: PropertyOwner Full Name: ABRAMS,TERI&ROBERT Address: Phone: None Contractor Contractor Type: General Company: R.A.Nelson&Associates Inc State License#: Phone: 970-949-5152 Projectinformation ProjeciName: AbramsResidence2018 ProjeclDescription: THISISAN EMERGENCYREPAIRREQUEST.Flood repairworkincludingfinishcarpentry,insulation, flooring,drywall,paint Fees Paid A ccounitt:001-0000.31111.00 -Building PermitFee FeeAmount: $492.25 Accoun1P:001-0000.31123.00 Building Plan ReviewFee FeeAmount: $319.96 Account#: 110-0000.31060.00ConstructionUseTaxFee FeeAmount: $500.00 Account#:001-0000.31128.00Will Call Fee(Building Scope) FeeAmount: $5.00 TotalPaid: $1,317.21 Conditions CONDITIONS UNDER WHICHPERMITS BECOME VOID: If construction is not begun within6 months from the date permitwas issued. If morethan5 months elapses betweeninspections. If incorrectinformationis given on the applicationat thetime the permitwas issued. 411 ChristopherJarecki-Townof Vail Building Official NOTICE:Byissuance ofthis Permittheapplicantagreesto complywithall Titlesofthe Townof Vail Code and all applicableStateand Federal law.Failureto do so will void this Permitand the applicantshallforfeitall applicablefees. °I1111 PERMIT FEE RECEIPT TOWN OF VAIL Case # B18-0507 Date Printed: 11/12/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B18-0507 Status: Approved Permit Number: Date Started: 11/08/2018 Permit Type: Construction Subcases Multi-Family Lot Number: 1 Property: 660 LIONSHEAD PL 109 (210107201037 109) (210107201037) Contacts Contact Type: Applicant Company Name: Ra Nelson LIc Full Name: Katelyn McDonald Address: PO Box 5400 51 Eagle Road#2 Avon,CO 81620 Email: kmcdonald@ranelson.com Contact Type: Property Owner Full Name: ABRAMS,TERI& ROBERT Address: Permit Fees Fee Information Account Amount Permit Fee 001-0000.31111.00 $492.25 Construction Use Tax 110-0000.31060.00 $500.00 Will Call Fee 001-0000.31128.00 $5.00 Payment Information Date Paid Payment Type Amount Construction Use Tax 11/12/2018 Check $500.00 Paid By:Carolyn Godfrey-Notes:ck#51346 5 RA Nelson LLC Permit Fee 11/12/2018 Check $492.25 Paid By:Carolyn Godfrey-Notes:ck#51346 5 RA Nelson LLC Will Call Fee 11/12/2018 Check $5.00 Paid By:Carolyn Godfrey-Notes:ck#51346 5 RA Nelson LLC FEE TOTAL $997.25 AMOUNT PAID $997.25 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 11/12/2018-4:31:33 PM-Generated by:cgodfrey 1/1 Environmental Developmentand Training ACM LLC. P.O. Box 452 Wheat Ridge, CO 80034 Phone 303-638-3778 October 29, 2018 Mike Dowling C.A.E Abatement LLC Box 5110 Eagle, Co 81631 Site: Apartment#4 and Unit 109 of 660 Lionshead Place located in Vail, Colorado. Task: 660 Lionshead Place in Vail, Colorado. Asbestos Visual and Air Clearance testing of Apartment#4 and Unit 109 Wall and Ceiling Flood cut areas. The abatement Contractor removed identified asbestos containing drywall wall and ceiling materials within two full containment systems within Apartment #4 and Unit#109 respectively. Clearance testing was conducted post removal of identified asbestos containing materials, and prior to planned repair and renovation of unit repair and renovation areas. Task 1 - Field Work: 1.0 Asbestos Clearance Project Scope of Work Conducted during Air Monitoring: A. Contractor conducted abatement according to Colorado Regulation 8, EPA, and OSHA containment work practices for OSHA clearances. B. Completionof final inspections,forapplicable ACM removal,andremoval of all materials, within the regulated areas. Environmental Development & Training, ACM LLC (EDT) conducted a post abatement visual investigation at the above-referenced site. The investigation was conducted to discern the successful removal of ACM material using applicable State of Colorado Regulation8, OSHA,and EPA regulations. 2.0 SAMPLE COLLECTION METHODS EDT ACM LLC used NIOSH method 7400,40 CFR 763 AHERA and OSHA 29CFR 9010 methodology during activities to support abatement activities. FINAL AIR SAMPLES: Clearance air sampling was conducted according to Colorado Regulation 8. All of the clearance samples collected within the work area were less than 0.01 F/CC, (fibers per Cubic Centimeter. No concentrations were observed in excess of the Maximum Allowable Asbestos Level (MAAL). 3.0 CONCLUSIONS Based on observations during the site visit, and the laboratory analytical results, EDT LLC ACM concludes the following: All Environmental and Final workArea or Clearance Air samplescollectedoutside and inside the regulated work area clearance criteria indicated; fiber concentrations less than or equal to 0.01 f/cc (fibers per cubic centimeter of air sampled). No fiber concentrations were observed in ex cess of the Maximum Allowable Asbestos Level (MAAL)per CDPHE. Based on sampling and analysis results attached, no further action is recommended or required for this phase of the project for the impacted areas. As additional abatement items are addressed environmental and clearance air monitoring should be performed according to Colorado and EPA Regulations. 4.0 LIMITATIONS Limitations Environmental Development and Training ACM LLC prepared this report, for the exclusive and present use of CAE Abatement. This report addresses certain physical characteristics of the site with regards to the release or presence of asbestos in limited, client determined, areas only. These services were performed in a manner consistent with practices common in the environmental health profession. The information and conclusions provided herein are valid only with respect to the specific locations and analytes investigated at the time this report was prepared. The findings, conclusions, and recommendations presented here are based on information available at the time the site was evaluated. In the event of any reuse or publication of any portion of this report, Environmental Development and Training ACM LLC shall not be liable for damages arising out or such reuse of publication. Any reuse a third party makes of this report, or any reliance on or decisions made are the responsibility of such third party. Environmental Development and Training ACM LLC accepts no responsibility for damages, if any,suffered by any third party as the result of decisions made or actions taken based on this report. I''tcd 7. Vd4og Kris Thomas Wilson President Environmental Development and Training ACM LLC Environmental Development and Training4CMLLC Phone 303-638-3778 r v Z 0000000000 Z C) 0 -1K000023 D m ww OC r r r r r r r r r r c m m m m 3 3 m C 3 m C CD CD CD W o 0 `o y 0 0 0 0 0 0 0 0 0 0 6 w C1 0 ".' L OZ m c0 'O LC:' c0 c0 A A A A A 0 N OO 0- N -0 - 0 m O it 6 CD 0 N j N t C ✓T m m rn m CD 5, N O CO CO V 01 01 A CO "0O D. -0 3.3. Z m 5,<. CD N N "' "' 3 co 3 3 iii m > A O z v m -- m c CD a N < '6 N a O_ 0 -0 CZ - ✓ O 1 N D O Z 0'1 a I— CD m Cl) S N r � m Z o m E,,,, m m m m m m m m m m m o rD ▪ 3 MMMKKKKKKK 0 O 70 73 O rn rn m 70 _ O 3 3 0 Co-0 - A C S 0 o 6 0 N 0, d 8, N N N N N N N N N N co C CD 7 NO O CO 0 CO 0 CO CO CO CO CO 0 W V) W N CI 01 O ~ 0 V V V V V V V V V V 0" .C. a1 D 70 0 a co W 0 01 cm A W N O O n) ivo V O J = m ii D o to z w Cl () I'17 u) o 30co -4 1211 1 ° O V V V V V V V V V V - C A < 3a o 3 CD xi — a co co co w co cn cn cn (xi cn .r.O.0D - 0 CD o y R D 55 D Rl `-o C a r m Z m y N y m 0 0. < O < N p, m 0 0 0 0 0 0 0 0 0 0 cp 0 O ti p o 0 0 0 0 0 0 0 0 0 0 Q N 3 < Z A T gal II o 0 ; m W oo C)„ d Z ° m o > DT N A CO A N A CO A N U1 r c, Iv 73 co Z Ow (V11 V V V V V V V V V V r'° P c 0 0 0 0 0 0 0 0 0 0 3 ..3 0 o E - = o � 7 O m < N II O O 0 N cn 11 N CA CO CO CO CA CO CO CO CO CO v- v 73 A A A 73 73 A 73 73 73 3 c co N N 0 N 0 o n 0 D xi x O O O O O O O O co O r 0 'm^ 00 0 0 0 0 0 0 0 0 0 0 O x0000000000 ° 3 A A A A A CO CO CO CO CO v _n.2 a 0 II 7 m co co c° §,- xm OF C) mx m CO X 0 O O co 07CO CO W CA W W W CA T N T 0m N Ell y fm/, N as .�.. Sy c 10 c x r — 3< j n m r: 0011466. TRUE ! 1c1! .-1 IrI . Po Box 2096, Edwards CO 81632 Ph. 970-390-5827 Email: ron@trueperspectivehc.com ASBESTOS REPORT 660 Lionshead PI units 107/104/4, Vail CO Prepared for Disaster Restoration Services Asbestos Inspection Conclusions 1. Laboratory results showed samples to be asbestos containing building materials in the following homogeneous areas unit 109,and unit 4.The type of material that showed positive was surfacing compound Per Regulations an homogeneous area is considered to not contain asbestos containing materials only if all samples submitted show negative. A homogeneous area shall be determined to contain asbestos based on a finding that the results of at least one sample collected from that area shows that asbestos is present. We highly recommend that the entire report including the standards of practice, limitations, scope of the inspection and inspection agreement be read as there may be other facts or conditions not contained in the document that may affect your conclusions or decisions. Inspected by: Ron Amass Date:10/18/2018 Time: 8:19 AM Asbestos Inspection 2122. 10/18/2018. Disaster Restoration Services. 660 Lionshead PI units 107/104/4. Vail, CO 81657. jake@disasterrestorationco.com, Melody@srebuilds.comPreg@disasterrestorationco.com. 970-376-0977 General Notes & Exclusions It is our understanding that the building was constructed in 1972 . This information was communicated to the inspector by the available listing documentation, client or representing Realtor at or before the time of inspection. The properties plans and specification sheets were not present at the time of inspection. These documents may have valuable information which may have relevant facts about current condition that cannot be readily seen by the inspector. We recommend that the be studied in full with any concerns being reviewed by an appropriate person. Reason for Inspection A water intrusion event has occurred, the nature of this intrusion is a broken pipe . The apparent areas affected are walls in units 107,109, and 4. Type of Inspection A limited bulk sampling of suspect ACM was conducted in accordance with Colorado State requirements. Surfacing materials: each homogenous area of less than 1000 square feet of surfacing , a minimum of three samples must be collected randomly. For each homogenous area of 1000-5000 square feet , a minimum of five samples must be collected. For areas larger than 5001 square feet a minimum of seven samples must be collected. Miscellaneous materials: at least one sample must be taken. A homogeneous area is defined as one which shares suspect material, texture,color, location, and/or apparent time of construction. Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 3 of 13 Thermal system insulation: At least 3 random samples from each homogeneous area. At least one bulk sample from each homogeneous area of patched thermal insulation if the patched section is less than 6 lineal feet. Introduction Ron Amass of True Perspective Home Consultants conducted an asbestos inspection and collected asbestos bulk-samples of suspect asbestos-containing materials (ACM)within the structure.. The purpose of the inspection was to identify and sample potentially hazardous friable and non- friable ACM. The type of inspection performed was Limited asbestos Inspection. The Limited Asbestos Inspection does not include a visual examination of the entire building, but is limited to a specific area of the building identified and described by the inspector. The areas inspected are as follows only the walls in the above listed units that were water affected The limited asbestos inspection did not constitute a full building inspection and does not fulfill the asbestos inspection requirements for structures that are to be demolished. Certifications The limited asbestos inspection and bulk-sampling was conducted by Mr. Ron Amass with True Perspective Home Consultants LLC. Mr. Amass is a CDPHE certified Building Inspector; having certification number 21688. The Inspection, Sampling Procedures and Laboratory Analyses The asbestos inspection was conducted by CDPHE certified Building Inspector.The inspection process included identifying and sampling suspect ACM within the pre-defined areas, submitting samples to an accredited laboratory for analysis, classifying the materials and assessing their condition, and providing a final report detailing the inspection and the analytical results of the bulk-samples. Statistically random bulk-samples representative of the suspect ACM of each homogeneous area were collected according to the guidelines published as EPA Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763 and CDPHE Regulation Number 8, Part B -Asbestos (Reg. 8). The Inspector has collected the appropriate number of bulk-samples to meet all regulatory requirements for the classification and quantity of each homogeneous area. Some minor destructive sampling was conducted; however, walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 4 of 13 The percentage of asbestos within each individual bulk-sample can vary depending on sample location, homogeneity of the material, and the type of application. Any sample reporting a "TRACE" amount of asbestos must be considered positive for asbestos greater than 1% unless it is re-analyzed utilizing the point-count method and verified to be less than 1%. Materials containing less than or equal to 1.00% asbestos are not regulated by CDPHE Regulation 8, Part B Asbestos. However, all demolition/abatement activities should be performed following the applicable Occupational Safety and Health Administration (OSHA) regulations. This would include, but not limited to, the appropriate asbestos training for the type of material being removed/disturbed as well as having a properly trained supervisor onsite, using wet removal methods, wearing adequate personal protective equipment (HEPA-filtered particulate respirators), medical surveillance of workers, personal- exposure air monitoring, area air monitoring in occupied buildings, etc. There may also be landfill disposal requirements for these materials, depending on the facility.True Perspective suggest that all demolition/renovation areas involving any amount of asbestos be subjected to visual inspections and a final clearance air testing by a CDPHE-certified Air Monitoring Specialist (AMS) after the work has been completed, but before any containments are dismantled and the area is reoccupied. Homogeneous Areas A Homogeneous Area (HA) includes materials that are uniform in appearance, color, texture and date of application. The asbestos content of the bulk-samples collected within a homogeneous area can be applied to the entire homogenous area if they conform to the above characteristics and the regulated minimum sample quantities of each type of material are collected and analyzed. Friability A material can either be friable or non-friable. A friable material is one that, when dry, can be pulverized, or reduced to powder by hand pressure,a non-friable material cannot. A non-friable material may become friable if its condition had deteriorated or has been impacted by forces that have rendered it friable. Classifications of Asbestos Containing materials (ACM) Samples of possible ACM are divided into 3 different classifications. Surfacing Material: sprayed or trowel applied onto structural building members or surfaces Thermal System Insulation (TSI): any type of pipe, boiler,tank, or duct insulation Miscellaneous Material: all other materials not classified in the above two categories. Material Condition Sampled materials are placed into one of the three following categories of conditions: Good: none to very little visible damage or deterioration Damaged: the surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the damage is evenly distributed, or one-quarter if the damage is localized Significantly Damaged: the surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over greater than one-tenth of the surface if the damage is evenly distributed, or one-quarter if the damage is localized Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 5 of 13 Sample Quantities At least the minimum number of samples from each homogeneous area were collected to meet all regulatory requirements for the quantity of material to be disturbed. The quantities listed in this report are approximate and on-site verification of the exact quantity of each material is required. The following outlines the minimum sample quantities required per homogeneous area: Surfacing Materials: up to 1,000 ft2 of material requires a minimum of three (3) samples; between 1,000 ft2 and 5,000 ft2 of material requires a minimum of five (5) samples; over 5,000 ft2 of material requires a minimum of seven (7) samples; one (1) sample of each patch Thermal System Insulation (TSI): each homogeneous area requires a minimum of three (3) samples; at least one (1) sample must be collected from each patch; and collect enough samples sufficient to adequately assess the material and determine the asbestos content for TSI fittings such as pipe elbows or Ts. Miscellaneous Materials: collect enough samples sufficient to determine the asbestos content Homogeneous area of suspected asbestos containing material A homogeneous area of suspected asbestos containing materials is as follows walls in the living room and bedroom in unit 107. I lir r . Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 6 of 13 MP !lei: 1 1 1 . .. I 1 r; LJ L 1 MMIMMI.111111. II I . Aliciiir _ NW Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 7 of 13 Surfacing Material: sprayed or trowel applied onto structural building members or surfaces. The approximate area of the material is 1500 square feet . The texture on the ceiling and walls is a trowel applied . The color on the ceiling and walls is Beige. The material condition is Damaged: the surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the damage is evenly distributed, or one-quarter if the damage is localized The possibility of damage or disturbance creating a friable condition is High as the home is about to undergo renovation or repair requiring removal of surfacing materials.. Homogeneous area of suspected asbestos containing material A homogeneous area of suspected asbestos containing materials is as follows walls and ceilings in unit 109. Surfacing Material: sprayed or trowel applied onto structural building members or surfaces. The approximate area of the material is 1500 square feet . The texture on the ceiling and walls is a skip trowel . The color on the ceiling and walls is grey. The material condition is Damaged: the surface is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenth of the surface if the damage is evenly distributed, or one-quarter if the damage is localized The possibility of damage or disturbance creating a friable condition is High as the home is about to undergo renovation or repair requiring removal of surfacing materials.. Homogeneous area of suspected asbestos containing material Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 8 of 13 - ~� A homogeneous area of suspected asbestos - containing materials is as follows walls and ceilings in unit 4. . Alt 6_1i4- • • f - /f 1 f . • • 1 {S`i . 111 1 tk / K • -1 I t wig' I -- fN- Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 9 of 13 V 1i} ; f _ _ - r^ *C ter. J i_. + - +:�.• 4 .•• u • 111111 5 — „ .. II Li. i iii. '::.,r... ; - . _.„- IIIII--7..............vi IF .. _ _ • ' - 411.6.1. _ IMMIIN ..:111 .m..-' •-• .r a -7 " ' : r, + x S ; Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 10 of 13 Surfacing Material: sprayed or trowel applied onto structural building members or surfaces. The approximate area of the material is 1000 square feet . The texture on the ceiling and walls is a orange peel . The color on the ceiling and walls is off white. The material condition is Significantly Damaged: the surface is crumbling, blistered,water-stained, gouged, marred or otherwise abraded over greater than one-tenth of the surface if the damage is evenly distributed, or one-quarter if the damage is localized The possibility of damage or disturbance creating a friable condition is High as the home is about to undergo renovation or repair requiring removal of surfacing materials.. Homogeneous area of suspected asbestos containing material A homogeneous area of suspected asbestos containing materials is as follows tape and joint compound in the walls and ceilings in the unit 107. Miscellaneous Material: all other materials not classified in the above two categories. off white. The material condition is Good: none to very little visible damage or deterioration The possibility of damage or disturbance creating a friable condition is High as the home is about to undergo renovation or repair requiring removal of surfacing materials.. Sampling Procedures Statistically random bulk-samples representative of the suspect ACM of each homogeneous area were collected according to the guidelines published as EPA Final Rule: Title II of the Toxic Substances Control Act(TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763 and CDPHE Regulation Number 8, Part B - Asbestos(Reg. 8). The appropriate number of bulk-samples to meet regulatory requirements for the classification and quantity of each homogeneous area. Some minor destructive sampling was conducted Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. Hidden asbestos containing building materials may exist. Conclusions Laboratory results showed samples to be asbestos containing building materials in the following homogeneous areas unit 109, and unit 4. The type of material that showed positive was surfacing compound Per Regulations an homogeneous area is considered to not contain asbestos containing materials only if all samples submitted show negative. A homogeneous area shall be determined to contain asbestos based on a finding that the results Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 11 of 13 of at least one sample collected from that area shows that asbestos is present. Ron Amass, a Colorado Department of Public Health & Environment certified building inspector, certification number: 21688, performed the inspection. Samples taken were sent to Sanair Laboratory, for PLM (Polarized Light Microscopy) analysis. If ACM is to be removed or disturbed in a single-family residence, and the total quantity exceeds any of the regulatory trigger levels of 50 linear ft. on pipes, 32 ft2 on other surfaces,or the volume equivalent of a 55-gallon drum, a CDPHE-certified General Abatement Contractor (GAC) is required to perform the work.The regulatory trigger levels within a commercial building are 260 linear ft. on pipes, 160 ft2 on other surfaces,or the volume equivalent of a 55-gallon drum. In addition, formal notification to CDPHE prior to the abatement of ACM as well as air monitoring, visual inspections, and final air clearances by a CDPHE-certified Asbestos AMS is required. DS can provide the client or building owner with a proposal for project design, abatement oversight and air monitoring upon request. CDPHE regulations allow for the demolition of a building that contains non-friable asbestos-containing materials, such as caulking, mastic or resilient floor tiles. However, demolition must be completed without causing the non-friable ACM to be rendered friable.Burning a building with any ACM is prohibited. Operations such as sanding, cutting, crushing, grinding, pneumatic jacking, etc. of ACM are not permitted. Recycling of building materials such as concrete, metal, or wood that are bonded or contaminated with ACM, e.g. glue, caulking, or mastic is also prohibited. If any of the non-friable asbestos containing materials are to be recycled and rendered friable after demolition (i.e. crushing mastic-coated concrete),these materials must be abated of all ACM prior to shipping offsite for recycling. OSHA regulations regarding occupational exposure during demolition activities is still mandatory. OSHA 29 CFR 1926.1101 requires that workers performing construction-related activities be protected from asbestos fibers in excess of the permissible exposure limit of 0.1 f/cc of air. Contractors are must comply with applicable provisions of OSHA 29 CFR 1926.1101 during demolition and renovation activities. These OSHA provisions include, but are not limited to, PPE and respirators, personnel training, personal- exposure air monitoring, employee medical surveillance, wet removal methods, signage for regulated areas, etc. REPORT LIMITATIONS: We certify that our inspectors have no interest, present or contemplated, in this property or its improvement and no involvement with the trades people or benefits derived from any sales or improvements.To the best of our knowledge and belief,all statements and information in this report are true and correct. 1.Purpose: The purpose of the inspection is to attempt to detect the presence of asbestos containing building materials by performing a visual inspection of the property and collecting samples to be analyzed by a laboratory. 2. Scope: The scope of the inspection is limited to the readily accessible areas of the property, and is based on the condition of the property at the precise time and date of the inspection, and on the laboratory analysis of the samples collected. Asbestos can exist in inaccessible areas, such as behind walls and under carpeting. As such, the report is not a guarantee that asbestos does or does not exist. The report is only indicative of the presence or absence of asbestos. 3.. Report: The CLIENT will be provided with a written report of the INSPECTION COMPANY's visual observations,and copies of the results of the laboratory analysis of the samples collected. The INSPECTION COMPANY is not able to determine the extent or type of asbestos contamination from visual observations alone. The report will be issued only after the laboratory analysis is completed. The report is not intended to comply with any legal obligations to disclosure. 4. Exclusivity: The report is intended for the sole, confidential and exclusive use and benefit of the CLIENT, and the INSPECTION COMPANY has no obligation or duty to any other party. INSPECTION COMPANY accepts no responsibility for use by third parties. There are no third-party beneficiaries to this agreement. This Agreement is not Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 12 of 13 transferable or assignable. Notwithstanding the foregoing, the CLIENT understands that the INSPECTION COMPANY may notify the homeowner, occupant or appropriate public agency of any condition(s)discovered that may pose a safety or health concern. 5.An Asbestos inspection is not a home (property) inspection. 6. An asbestos inspection is not a comprehensive indoor air quality inspection. ©True Perspective Home Consultants Inc. 2018. All Rights Reserved.This document contains material protected under Federal Copyright Laws. No part of this document or any of its contents may be reproduced,copied, modified or adapted, without the prior written consent of the author and True Perspective Home Consultants, Inc. Copyright by True Perspective Home Consultants© 10/18/2018 Not Transferable Without Written Permission. Page: 13 of 13 Reservoirs Environmental,Inc. Effective April 2,2018 Reservoirs Environmental QA Manual Q:\QAQC\Lab\Reservoirs Environmental QA Manual.doc REI LAB Reservoirs Environmental, Inc. T October 19, 2018 Subcontract Number: NA Laboratory Report: RES 420763-1 Project#/P.O.# Lions Square Lodge Project Description: Unit 107/109/apt 4 Ron Amass True Perspective Home Consultants P.O. Box 2096 Edwards CO 81632 Dear Customer, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program(NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table.The results have been submitted to your office. RES 420763-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental,Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, Ci Jeanne Spencer President P:303-964-1986 5801 Logan Street,Suite 100 Denver,CO 80216 1-866-RESI-ENV F:303-477-4275 www.reilab.com Page 1 of 1 Reservoirs Environmental,Inc. Effective April 2,2018 Reservoirs Environmental QA Manual Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITIONBY VOLUME RES Job Number: RES 420763-1 Client: True Perspective Home Consultants Client Project Number/P.O.: Lions Square Lodge Client Project Description: Unit 107/109/apt 4 Date Samples Received: October 19, 2018 Method: EPA 600/R-93/116-Short Report, Bulk ND=None Detected Turnaround: Rush TR=Trace,<1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: October 19, 2018 Client Lab L Asbestos Content Non Non- Sample I D Number A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) (%) (%) (%) 1 107 EM 2186233 A Light tan paint w/white compound 7 ND 0 100 B Offwhite/tan drywall 93 ND 15 85 2 107 EM 2186234 A Off white compound w/light tan paint 15 ND 0 100 B Offwhite/whitedrywall 85 ND 15 85 3 107 EM 2186235 A Cream tape 7 ND 90 10 B Off white compound w/light tan paint 10 ND 0 100 C Offwhite joint compound 10 ND 0 100 D White/tan drywall 73 ND 20 80 4 107 EM 2186236 A Off white compound w/light tan paint 15 ND 0 100 B White/tan drywall 85 ND 20 80 5 107 EM 2186237 A Off white compound w/light tan paint 10 ND 0 100 B White/tan drywall 90 ND 0 100 6 107 EM 2186238 A Off white compound w/light tan paint 7 ND 0 100 B White/tan drywall 93 ND 15 85 TEMAnalysis recommended for organically bound material(i.e. floor tile) if PLM results are<1%. P: 303-964-1986 5801 Logan Street,Suite 100,Denver,CO 80216 1-866-RESI-ENV F: 303-477-4275 www.reilab.com Page 1 of 2 Reservoirs Environmental,Inc. Effective April 2,2018 Reservoirs Environmental QA Manual Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITIONBY VOLUME RES Job Number: RES 420763-1 Client: True Perspective Home Consultants Client Project Number/P.O.: Lions Square Lodge Client Project Description: Unit 107/109/apt 4 Date Samples Received: October 19, 2018 Method: EPA 600/R-93/116-Short Report, Bulk ND=None Detected Turnaround: Rush TR=Trace,<1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: October 19, 2018 Client Lab L Asbestos Content Non Non- Sample I D Number A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) (%) (%) (%) 7 107 EM 2186239 A Light tan paint 2 ND 0 100 B Cream tape 5 ND 90 10 C Off white joint compound 5 ND 0 100 D White/off white compound w/yellow fibrouswoven 8 ND 7 93 material E White/tan drywall 80 ND 20 80 8 107 T EM 2186240 A Off white compound w/light tan paint 5 ND 0 100 B Cream tape 5 ND 90 10 C Off white joint compound 5 ND 0 100 D White/tan drywall 85 ND 20 80 9 107 T EM 2186241 A Off white compound w/light tan paint 5 ND 0 100 B Cream tape 5 ND 90 10 C Off white joint compound 5 ND 0 100 D Light pink/tan drywall 85 ND 15 85 TEM Analysis recommended for organically bound material(i.e. floor tile) if PLM results are<1%. A2y-,--__SZ--c/ --'t-- Ryan Shilling Analyst/Data QA P: 303-964-1986 5801 Logan Street,Suite 100,Denver,CO 80216 1-866-RESI-ENV F: 303-477-4275 www.reilab.com Page 2 of 2 o`� 2 M M M rtvA(,M" I.S3'r M Y z co z i o 93J ! ^ O WE 0) 7 a LI c Y C 3. LL g E V E N N co 16 Z oma u 8$ II � ' R. o X W � tI N 2• - . Q 3 aS U • = 3 C■ a &leumuoo# c 0 0u LLu OQCcocop. v U it d Z a I. e n e g w epo0 x!levy a a s ) I- > Q'oAI , a t E U a ealV/(l) n v c C Zelunwn etdweg b El 0 O - 1411 U S31ON a3HLO 210 SIYWNI S.N31dWYS J ., Ilkai'''' uopeouenp 'uoge3pluepl '-1+ -Ploy $ m It N gpo uopeoyllUBnp JO •/+ .W 8 A v c 1 i, - uO7e'�Jguenp JO -1+ sname S 0 " '- 1V C 1.d..)) N uopeognuenp JO -/+ suuolp0 G a, LL MI W uopeoypusnp Jo /+ loo 3 m m� 41 7i: O) J uopeaypuen0 JO -/+ lunOO eleld olgaey co m- E E i a Z •1+ :euels�l v ` d P a ,Q t 7 Q -1+ :LH:LS10 goo3 rn d o 0 ' o@W _Q ) /+ :WlouOwleS ° sa—oC nv o C y H3W-SOINYO2O € O LL O W a -„ Leossew 'ewn3 BuIPIeM 'd131 '9 Y21p23 - if) _l 1, � W (S)el/Owl-S11/1311 = gQ. . 80 C \s E o elgeJldse2l 'lelol-isna € o S E N C P YHSO '900PL 'VOOPL Wpd a 5,f 0 S. c c n` W sdeid IoenPul•OSI 'oeA-Oloty luenb•!wes - e 3 9 V U a w hien° '• /+ 'OSI 'ZOYL 'II leeel 'Y213HY- W31 qg N ' *: Q luno Iwod Lode)Buol Voda)JO)S - Wld xx3C14.• X � , 13 22 ih°2 _ a W C o m •. c U 0 AOvLi i R m (1 Q O 9 T 3 yNy ati Q E_ E z UZ c : 0 N ' -�. H F- • I'nl E 01 8s I I7° g 0 c �l x E m >. 2 m Q ' V c m m m W a N NJG,z `ou) `n a OfI I _ .2 I C 0 u . o .- N J ./ J E - w I N S _ E i t W pe .,,Oo - °° r c o e' IC) Q u) •+�'�J�`\'' iii a II �q nto ,i �n c+� Y N v - a c W ea 0 x x dlll 92 U_ u_ T ICY I I m Z5 m m co I s U y U - E E i_ d m a a' = N s w w 7 i O d = (n D t - II o iti % ce o CC U O I =• U CL co 0 43 - u--r- (2 c) 2 .f) O d ti A v = 2 ' >. �� Q co a y Z• W ` 7 O OF c*, , vrn �I� Q vO c (\ fl a m E q cQ -�a)0 m _ Q o w c ' 00.N i 5, O -I - ,; a 0 z9m, O s m Q °5 >- j « \ A N ••O. m •N o u yr rr !� � , ` = W a ° Oa ) Q Et8 m O ,.- : — = a NO _ d97 - v w OO nR e OO J Q. m 'I, NOm• N R �; _ I �. f c I- c. - V) �.-� O W O ip, Wa mw O __�/ )` J� 1^ „A 0 F. 2occ)o U-I 7 7 g s u) _, Z a, U m U v w O a - r• N el V u7 co N CO C a) N N 0 0 a Q a U f cc u. O w v) 2 h U z CC J a a Reservoirs Environmental,Inc. Effective April 2,2018 Reservoirs Environmental QA Manual Q:\QAQC\Lab\Reservoirs Environmental QA Manual.doc REI LAB Reservoirs Environmental, Inc_ October 19, 2018 Subcontract Number: NA Laboratory Report: RES 420766-1 Project#/P.O.# None Given Project Description: None Given Ron Amass True Perspective Home Consultants P.O. Box 2096 Edwards CO 81632 Dear Customer, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program(NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table.The results have been submitted to your office. RES 420766-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental,Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, - 1�... Jeanne Spencer President P:303-964-1986 5801 Logan Street,Suite 100 Denver,CO 80216 1-866-RESI-ENV F:303-477-4275 www.reilab.com Page 1 of 1 Reservoirs Environmental,Inc. Effective April 2,2018 Reservoirs Environmental QA Manual Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITIONBY VOLUME RES Job Number: RES 420766-1 Client: True Perspective Home Consultants Client Project Number/P.O.: None Given Client Project Description: None Given Date Samples Received: October 19, 2018 Method: EPA 600/R-93/116-Short Report, Bulk ND=None Detected Turnaround: Rush TR=Trace,<1%Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: October 19, 2018 Client Lab L Asbestos Content Non Non- Sample ID Number A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) (%) (%) (%) 1 4 EM 2186249 A White paint 3 ND 0 100 B Off white compound 7 Chrysotile 2 0 98 C White/tan drywall 90 ND 15 85 2 4 EM 2186250 A White compound w/tan paint 10 ND 0 100 B Gray/tan drywall 90 ND 15 85 3 4 EM 2186251 A White paint w/white compound 3 ND 0 100 B White compound w/light beige paint 7 ND 0 100 C White compound w/off white paint 10 ND 0 100 D White/tan drywall 80 ND 15 85 4 4 EM 2186252 A White compound w/light beige paint 10 ND 0 100 B White compound w/white paint 10 ND 0 100 C White/tan drywall 80 ND 15 85 5 4 EM 2186253 A White compound w/light beige paint 15 ND 0 100 B White/tan drywall 85 ND 15 85 TEM Analysis recommended for organically bound material(i.e.floor tile)if PLM results are<1%. P: 303-964-1986 5801 Logan Street,Suite 100,Denver,CO 80216 1-866-RESI-ENV F: 303-477-4275 www.reilab.com Page 1 of 2 Reservoirs Environmental,Inc. Effective April 2,2018 Reservoirs Environmental QA Manual Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITIONBY VOLUME RES Job Number: RES 420766-1 Client: True Perspective Home Consultants Client Project Number/P.O.: None Given Client Project Description: None Given Date Samples Received: October 19, 2018 Method: EPA 600/R-93/116-Short Report, Bulk ND=None Detected Turnaround: Rush TR=Trace,<1%Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: October 19, 2018 Client Lab L Asbestos Content Non Non- Sample ID Number A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) (%) (%) (%) 6 4T EM 2186254 A White compound w/white paint 7 ND 0 100 B Light gray/tan drywall 93 ND 25 75 7 4T EM 2186255 A White compound w/white paint 10 ND 0 100 B Light gray/tan drywall 90 ND 15 85 TEM Analysis recommended for organically bound material(i.e.floor tile)if PLM results are<1%. '✓ Andrew Roberts� Michael Scales Analyst Data QA P: 303-964-1986 5801 Logan Street,Suite 100,Denver,CO 80216 1-866-RESI-ENV F: 303-477-4275 www.reilab.com Page 2 of 2 z 0 L11 � _ O dO ca 4 C�U sb- CO (.0Z �' a = c0 z - - rd O w a .� y N } v i o d b € CD at m I a 3' n € o 0 LLl no ccs W n n u $S r o c v z a g at 1 E U 2 O a c Z oo m o- w u >- O x 3 � Ili a °Q oUa Q a = o O 02LLu Seueuo°# — u 0. 1-1 = ii N S z 5 oQ _ - .0 W u . a \I Q o mbIl) n Cr O s ewnIOA eldweS d J 0 0 eI, U o r. U S31ON 213H1O LO SIVWNI S.213IdWVS gg 1121 s o N L uopeWyp alpuenO 'ueouePl '-1+ PW Io ' RI a) uopeo puenO JO -1+ :W 8 A LCL2 r 3r 14 1. 'V uogeopuenO to •1+ :muneS 0 5 wl „ R a uopeaynuenO 10 •1+ :Swm11oo 9 ° g CD CO C LL _ y uopeaypuen0 JO -/+ :1oa 3 m MMI.1.1.��� ..e u u a ce W O j uopeoypuen0 /o -/+ .luno°meld algaeyl g,.-.--..-� s w w en v 2 W -/+ :ell6uowles MiNIMMEIMMMM� e,f a n. D o 1 V O W H13W .. .. . -S3INVOIO■ . . .. i'1 ' was ag mow 'ewnj EuPleM 'B'dial. V>1°a 111111111111111111 w (S)eVouy-Ov13w _ 5 € 1 ewe,laseu 'Imol-ism)1111111111111111111.111111111 € g e t C 2 zp _ VHS° 'eOOPL 'VOOPL- Mod......■�E.o� 5 o 12-2 5 al >i w °a:0% uenWl OSI 'aen-aaryy 'luenb 1we m 3 �J} U U W. w wenp /+ 'OSI 'Z04L 'll lanai V2131-1V W31,,,,,,,,n '� ° o 0CsJ E Q luno°w d •'UOdeJ 6u01 'code)MIS - Wld x x 2 'u! �1 CD CO ( c - .N u o c c [ _ c o 0 = In i W `/�,aIll: ilig v�.wi N m a) ligl ‘ x "' E � T . o � x` .1 E Q � � �o C-? WO O O is N i's". O > it E cn o 0 0) I A n� 1� O co L m m 0 7 a0 O 8 W N d N N Q a a y N V 0 - C c , g T N N (7 y N S m V_ LL " ti 3 a c x = E E :� y 5,a oo ,t a) IS, N r Cl) e3 w w N 0 vi � \ I I O 2 3 s 2 . c, . >_ ii,....,,,: ,,,.__. 2 up E c c oa c JO w C o O0..04 re O 3 ,_ x Q c w $ CO 0 o p t m a 0)d JwJ , vp o a) mC 0. Q.- 0 x E0)O 1 r- r N )- w I - s r U 8 cD E I-- E 1- 0 (0 - o a CI o c CO '1 ) O W.ate. C00 a Q N Q' c) = Z O _0 N O !] Q a Lj r:1 U a i O w u) �n U e- N M R In c0 ao a) O z IY J Ir CC Reservoirs Environmental,Inc. Effective April 2,2018 Reservoirs Environmental QA Manual Q:\QAQC\Lab\Reservoirs Environmental QA Manual.doc REI LAB Reservoirs Environmental, Inc_ October 19, 2018 Subcontract Number: NA Laboratory Report: RES 420767-1 Project#/P.O.# None Given Project Description: 107/109/4 Ron Amass True Perspective Home Consultants P.O. Box 2096 Edwards CO 81632 Dear Customer, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program(NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table.The results have been submitted to your office. RES 420767-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental,Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, - 1�... Jeanne Spencer President P:303-964-1986 5801 Logan Street,Suite 100 Denver,CO 80216 1-866-RESI-ENV F:303-477-4275 www.reilab.com Page 1 of 1 Reservoirs Environmental,Inc. Effective April 2,2018 Reservoirs Environmental QA Manual Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITIONBY VOLUME RES Job Number: RES 420767-1 Client: True Perspective Home Consultants Client Project Number/P.O.: None Given Client Project Description: 107/109/4 Date Samples Received: October 19, 2018 Method: EPA 600/R-93/116-Short Report, Bulk ND=None Detected Turnaround: Rush TR=Trace,<1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: October 19, 2018 Client Lab L Asbestos Content Non Non- Sample ID Number A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) (%) (%) (%) 1-109 EM 2186242 A White compound w/gray/tan paint 20 ND 0 100 B White/tan drywall 80 ND 15 85 2-109 EM 2186243 A White compound w/gray/tan paint 30 ND 0 100 B White/tan drywall 70 ND 15 85 3-109 EM 2186244 A Gray paint w/white compound 5 ND 0 100 B White/tan drywall 95 ND 15 85 4-109 EM 2186245 A Off white compound gray/tan paint 6 ND 0 100 B Off white/tan drywall 94 ND 10 90 5-109 EM 2186246 A White compound w/gray/tan paint 20 ND 0 100 B Off white/tan drywall 80 ND 15 85 6-109 EM 2186247 A White paint 6 ND 0 100 B White compound w/gray/tan paint 20 ND 0 100 C Off white compound 30 Chrysotile 2 0 98 D Off white/tan drywall 44 ND 15 85 TEM Analysis recommended for organically bound material(i.e.floor tile)if PLM results are<1%. P: 303-964-1986 5801 Logan Street,Suite 100,Denver,CO 80216 1-866-RESI-ENV F: 303-477-4275 www.reilab.com Page 1 of 2 Reservoirs Environmental,Inc. Effective April 2,2018 Reservoirs Environmental QA Manual Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITIONBY VOLUME RES Job Number: RES 420767-1 Client: True Perspective Home Consultants Client Project Number/P.O.: None Given Client Project Description: 107/109/4 Date Samples Received: October 19, 2018 Method: EPA 600/R-93/116-Short Report, Bulk ND=None Detected Turnaround: Rush TR=Trace,<1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: October 19, 2018 Client Lab L Asbestos Content Non Non- Sample ID Number A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R (%) (%) (%) (%) 7-109 EM 2186248 A White tape 8 ND 90 10 B White joint compound 10 ND 0 100 C White compound w/gray/tan paint 15 ND 0 100 D White compound w/tan paint 15 ND 0 100 E Off white/tan drywall 52 ND 15 85 TEM Analysis recommended for organically bound material(i.e.floor tile)if PLM results are<1%. \A 3far f7 AC). pe Landon Spells Paul D. LoScalzo Analyst Data QA P: 303-964-1986 5801 Logan Street,Suite 100,Denver,CO 80216 1-866-RESI-ENV F: 303-477-4275 www.reilab.com Page 2 of 2 n 2 0 a Z �1 O Y N ,_ q.-i-.. -r.,. -• ...,,. z. j.:C k r_, - C I` r'r d ; } h h m o a o_ g to N O J 1 Z ...-60D C C C'lM E Z V' 'r` W1• a h (f) r W 1 i U uN � P co I a 3 88 e 0 E y E s U co ii d W Y 11 LL ~ U = ucu ? z � m',a � " , 8 - 0 ' E E o X o g l< % 9 Et Ig Q Q 11 C U ' U c o 88 r is o u. u if LL c o a o ( 0 t g SJeweiuo0# - 0 _. S z J II II II II - e N III F - •a c w POS X!AeYY " E E V Q p aica 2 < eaJV/(i) - ca a a CZ awnloA aldweg o 0 U t SILOS 21314.1.0 210 SlYWNI S.a3ldVVS ►W N Itap iva N uogeoypuenp •uoReowueq '•1+ :DIoW _ _ 8 Y uo9eoynuenO Jo •/+ :W 8 A 1� a M w U uo98dyauenp JO 1+ :manes 8 w e C ` rn uopeoy!luenp JO y+ :swwj!aO a li LL a CV 00 l) - ` Vl UOlW 4A)uenD to -1+ :!po 3 C m h\ 1� *ctx w CUO w a J uo9eoynuenp JO •/+ :moo eleld o!OaeV c0i ( ` E E M A N Z •/+ :eue)sr) a= N f/ w w 2 N d o t < 1+ :LH:LS1O!h•3 . d o 0 C�� c L 4 W y+ :elleuow!eg o a s LJ 00 E C o c $ o H13W SOINVO)JO g 3 0 W 0 .. LL u 2 m mossWWIWI 'ewnd BwpleM viol.-a Vi!O I =Ill r'S a, _ ulna 0 0.tai ui (s)eiNeuV-SMV13W t U c e,Gendsed 'IeWl-1Sf10 € o s C d IC�' 2 VHSO '800PL 'VOOPL • WOd p, g E V gt c >I u(a sda I�IDul•OSI 'oen•oloiW luena!weS � 0 8 \ U U �I. W 'WenO -1+ 'OSI 'ZOPL 'II Wel 'VM3HV- W31 �/ '8 Q - i N 0$ o - luno3 Wlod uoda,6uol uodaJ uouS - Wld x X X"� �S 2 u 0 1 C; NW C 3i. . -. 1` > T O C o A. C C C CO W QN F 1- - _ v, a z \� (7, `Co' W c I v o o V _ o a V 0 5 cc 7, CCa >.. a o@ �. O O T YIC C E 1141 Q ° - �,I C _ i F- n a` M a ^1 = a g"" E 1y 0 E T a Y C ' i N 0 CO O l0 m a I c : n itB. . O d N !��1l £ , L E a ,0 T T O M 2 q 3 Q c 4 0 0 W O•Z In `° E NI I N 4 2 5 yt 4 Q n II M O Off) I >C N V I,- O _ T T L I j AV- COp e h -t \ N a_ , N p o V y N C W' S = 0 w II A N N f") I I I 4 9 CO CO a LL LL C 1E E -CO - Y U 0 I I I . i e v) o ' E E d T a ii -C C• CC N o = J g"t O o .5 'a.2 1,„\.3. 4-.----- clo O _ co 2 0 o E.: o.0 d _ � e ate; ?_ W 'u o C O H E' O h o R E $ U >, UF' Q Q -D m E U a 3 � sc a� 0_ o re °' J ° w a • C / - S o h o12,...1-41.--es... 2 9 0 a> O a Q mQ o6 aJ I j a q m 4.. O 4 Q m A 3 v N m m a J w J U O n h E Z. O O O '� \. o. v a> = 0 -a- a) N • `' F ? ay�i F' J = J v E ` / 1 uE@i w w y T U U to E ~ 1- U V) - - 3 h m d c u) 0 % M S GI t1) 6 ;:. 3 A a y Y w a w °o Q o O c R R ~ A Q 8 i Ln O 8 y _ v E of V_ e F a a' o i m a Jay O O U a a` n` Q d 0 2' LL 0 W u) 2 • y 0 Ct ELEcarRicA November 6,2018 Hello Kate, Coppers ElectricalService h as inspected Unit 109 and Apartment#4 We opened panels,switch openings,and outlets.All contactsarein excellent condition. Th ebussing in th epanels are also in good condition.Th erewill be some cover plates to install. I am confidentthereis no water damage to eitherUnit 109 or Apartment#4. Apartment#4 will need new outlets due whenplasterand paint is done,theywill be ruined. Cost on tamper resistantoutlets,plates and installation will be$600. UNIT 107 will need new GFCI arc faultcombo receptacle's,new dimmers and outlets and under cabinet LED lights LED lightsis whatis currentlyin theunit. In addition,thepeninsulawill need to be rewired. To rewireth epeninsula will be$350 Receptacle's,GFCl/AFCI combo dimmer installationwill be$900 I h aven'tf ound cost on th esame LED under cabinet lights I would budget$1000 dollars most likely it would be less. UNIT 109 will need outletsreplaced cost on tamper resistantreceptacle'sand labor will be$600. Please let me know if you h aveany questions. Th ankyou, Dave Da vidHeredia Coppers Electrical Services,LLC PO Box 4678 Eagle,CO 81631 9 70-9 04-09 55 copperselectrical@gmail.com Coppers ElectricalServices,PO Box 4678,Eagle,CO 81631 970-904-0955 Ph one copperselectrical@gmail.com