Loading...
HomeMy WebLinkAboutB18-0509_Approved Documents_1542408327.pdf 75 South Frontage Road Construction 0West, TOWN OF VAIL B18-0509 h -' Vail,CO 81657 Issued: 11/16/2018 TOWN OF VAIL Office:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 4800 MEADOW DR 23 (210112423023 23)(210112423023 ) Unit#:23 ParcelNumber: 210112423023 Subdivision:RIVERBEND ATVAILLot:23 BK-0341 PG-0801BK-0405 PG-0683QCD 01-10-85BK- LegalDescription: 0520 PG-0861 QCD 12-29-89 BK-0521 PG-0360 QCD 12-29-89 BK-0599PG-0437QCD 11-12-92 BK- 0611 PG-0134 QCD 06-02-93R766876BSD 08-16-01R840165 QCD 07-03-03 R843561 QCD 08-08- 03 Contacts ContactType: Applicant Full Name: Debbie Cary Address: PO Box 810,825-A ChambersAve PO Box 810,825-A ChambersAve 825- Phone: 9703282699 A ChambersAve Eagle,CO 81631 ContactType: PropertyOwner Full Name: LORENZ, ELIZABETH ANN Address: Phone: None Contractor Contractor Type: Mechanical Company: R&H Mechanical LLC State License#: Phone: 970-328-2699 Projectlnformation ProjeciName: LorenzResidence2018 ProjectDescription: Remove Old Furnace and ReplacewithNew Goodman 80%140,000BTUFurnace. Use ExistingDuct Workand Install New ExhaustPipe to ExistingTermination. Install New Thermostat. Fees Paid A ccounP:001-0000.31111.00 -MechanicalPermit Fee FeeAmount: $100.00 Account#:001-0000.31123.00MechanicalPlanReviewFee FeeAmount: $25.00 Account#:001-0000.31128.00 Will Call Fee(Mechanical Scope) FeeAmount: $5.00 TotalPaid: $130.00 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within6 months from the date permitwas issued. Ifmorethan5 months elapses betweeninspections. If incorrectinformationis given on the applicationat thetime the permitwas issued. ChristopherJarecki-Townof Vail Building Official NOTICE:Byissuance ofthis Permittheapplicantagreesto complywithall Titlesofthe Townof Vail Code and all applicableStateand Federal law.Failureto do so will void this Permitand the applicantshallforfeitall applicablefees. °11111 ' PERMIT FEE RECEIPT TOWN OF VAIL Case # B18-0509 Date Printed: 11/16/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B18-0509 Status: Approved Permit Number: Date Started: 11/09/2018 Permit Type: Construction Subc ases Multi-Family Lot Number: Property: 4800 MEADOW DR 23 (210112423023 23) (210112423023) Contacts Contact Type: Applicant Company Name: R and H Mechanical, LLC Full Name: Debbie Cary Address: PO Box 810, 825-A Chambers Ave PO Box 810, 825-A Chambers Ave 825-A Chambers Ave Eagle, CO 81631 Email: debbiec@randhmechanical.com Contact Type: Property Owner Full Name: LORENZ,ELIZABETH ANN Address: Permit Fees Fee Information Account Amount Permit Fee 001-0000.31111.00 $100.00 Will Call Fee 001-0000.31128.00 $5.00 Payment Information Date Paid Payment Type Amount Will Call Fee 11/16/2018 Credit Card $5.00 Paid By: -Notes:visa-david young Permit Fee 11/16/2018 Credit Card $100.00 Paid By: -Notes:visa-david young FEE TOTAL $105.00 AMOUNT PAID $105.00 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 11/16/2018-3:41:08 PM-Generated by:cgodfrey 1/1 Goodman GMH8 / GDH8 � J Air Conditioning & Heating DUAL$AVERTM GAS FURNACES PRODUCT SPECIFICATIONS The Goodman® GMH8/GDH8 80% AFUE Dual$aver'"" Convertible, Multi-Speed Multi-Position Gas Furnaces feature a patented aluminized-steel tubular heat exchanger and durable Silicon Nitride Hot Surface Ignition system. This furnace is run-tested for heating or combination heating/cooling applications. With a heavy-gauge, reinforced, insulated steel cabinet and durable baked enamel finish,this unit can be installed in ja variety of locations. Standard Features I • • Patented TuffTubeT"'dual-diameter tubular heat (Goodman) exchanger with lifetime limited warranty plus 10-year 'I limited furnace replacement warranty* • Two-stage gas valve with revolutionary new convertible technology that allows installer to activate the two- stage valve with the flip of a dipswitch • Silicon Nitride igniter with patented adaptive learning control for maximum igniter life • Furnace control board with self-diagnostics, color-coded low-voltage terminals and provisions for electronic air cleaner and 24-volt humidifiers • Control board stores the last five diagnostic codes in 80% AFUE memory;simple push-button activation outputs the fault history to a flashing red LED • Low constant fan allows homeowner to activate the low MULTI-POSITION CONVERTIBLE heat speed to efficiently circulate air throughout the home • Self-adjusting feature automatically adjusts furnace to MULTI-SPEED high or low stage based on outside temperature with- out an outdoor temperature sensor Cabinet Features HEATING INPUT: 45,000-140,000 BTU/H • Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish • Foil-faced insulation lines the heat exchanger • Designed for multi-position installation: upflow, DUAL left or right DUAL • Removable bottom for side or bottom return applications • Convenient left or right connection for gas and electric service 1414R114'41: 1 • Coil and furnace fit flush for most installations I REPLACEMENT 0 NEAT EXCHANGER ;,HEATEXCHANGER 4 : `art;lii7 L.l.l, ''a: °•,, wuLUM mummy Helle7aireJ ° us oFiz' tet: �<•�j �NT�� yr SS-GMH8 www.goodmanmfg.com 11/08 Supersedes 8/08 PRODUCT SPECIFICATIONS NOMENCLATURE G M H 8 70 4 B X A 1 2 3 4 5,6,7 8 9 10 11 Brand Revisions: G Goodman® Brand A Initial Release or Distinctions' ' B 1st Revision C 2nd Revision Airflow Direction C Downflow/Horizontal D Dedicated Downflow NOx, H High Airflow N Natural Gas K Dedicated Upflow X Low NOx M Upflow/Horizontal Cabinet Width Description A 14" ✓ Two-StageNariable-speed B 17%" H Two-Stage/Multi-speed C 21" S Single-Stage/Multi-speed D 241.4' E Two-Stage/X-13 Motor AFUE Maximum CFM @ 0.5" ESP+ 95 95% 3 1,200 9 90%+ 4 1,600 8 80% 5 2,000 MBTU/h 045: 45,000 115: 115,000 070: 70,000 140: 140,000 090: 90,000 ACCESSORIES Model Description GMH8 GDH8 All Models All Models LPM-05 LP Conversion Kit (Springs & Orifice) Al HAO2 High-Altitude Natural Gas Kit ' AFE18-60A Fossil Fuel Kit SBT 14/17/21* Downflow Sub-base * Supplied by McDaniel Metals THERMOSTATS Model Description CHT18-60 Cooling/Heating, Mechanical CH7OTG Cooling/Heating, Digital, Non-programmable CHSATG Cooling/Heating, Mechanical H2OTWR Heating Only, Mechanical 2 www.goodmanmfg.com SS-GMH8 PRODUCT SPECIFICATIONS SPECIFICATIONS co Z Co Z Co Z Co z CO Z Co Z oo Z Co Z ao 0o X oo X oo X = Q = Q = c0 Co= Co= = C) = C) = 0 _ = Q Co= = U mm mo o mo o mo mu, m0 02 00 Do 0e2n C9 41 C9 r-. C9 ti C9 0 C9 o CD rn C9 C9 d- C9 d' C9 r- C9 a� 0 , o O O o m o r i- o O o Heating Capacity Input' 45,000 70,000 70,000 90,000 90,000 90,000 115,000 140,000 45,000 70,000 90,000 115,000 Natural Gas Output' 36,000 56,000 56,000 72,000 72,000 72,000 92,000 112,000 36,000 56,000 72,000 92,000 LP Gas Output' 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 32,000 48,000 64,000 80,000 AFUE2 80 80 80 80 80 80 80 80 80 80 80 80 Available AC @ 0.5" ESP 3 3 4 3 4 5 5 5 25 - 55 25 - 55 30 - 60 40 - 70 Temperature Rise Range (°F) 25 - 55 20 - 50 30 - 60 35 - 65 40 - 70 3 3 4 5 Circulator Blower Size (D x W) 10"x 6" 10"x 8" 10"x 10" 10"x 6" 10"x 6" 10"x 8" 10"x10" Horsepower @ 1750 RPM '/a '/z '/a 1.4 % '/a %a '/2 'A Speed 4 4 4 4 4 4 4 4 4 4 4 4 Vent Diameter' 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" No. of Burners 2 3 3 4 4 4 5 6 2 3 4 5 Filter Size';(in2) Permanent' 290 385 290 385 480 290 290 385 480 Disposable 580 770 580 770 960 580 580 770 960 Electrical Data Min. Circuit Ampacity 5 8.1 12.5 8.1 12.5 14.7 8.5 8.5 12.9 12.9 Max. Overcurrent Devices 15 amps 15 amps Ship Weight(lbs) 120 130 143 153 163 120 130 153 175 * Low NOx model available 1- Natural Gas BTU/h;for altitudes above 2,000',reduce input rating 4%for each 1,000'above sea level. Low-fire rate is 75%of high-fire rate 2- DOE AFUE based upon Isolated Combustion System(ICS) 3-Vent diameter may vary depending upon vent length.Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA)and the Canada National Standard of Canada,CAN/CSA B149.1 and CAN/CSA B1422(in Canada). 4- Permanent air filter size is based on 600 FPM velocity.Check with filter manufacturer for specific details. 5- Minimum Circuit Ampacity=(1.25 x Circulator Blower Amps)+ID Blower amps.Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. 6- Refers to maximum recommended fuse or circuit breaker size.May use fuses or HACK-type circuit breakers of the same size as noted. Notes: • All furnaces are manufactured for use on 115 VAC, 60 Hz,single-phase electrical supply. • Gas Service Connection '/z' FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-GMH8 www.goodmanmfg.com 3 PRODUCT SPECIFICATIONS GMH8 DIMENSIONS Alt.Vent Location 4 7/16" 2 1/16" Alt.Vent Location 19 5/8" _ A 1141,jilli o 12 3/16" 9 5 16" II ,� fife:ageI, 39 . Alt.Gas Inlet ii Gas Locationa Alt.High Voltage 01111.11111111111111111111111111111111111 High Voltage Inlet • Low VolAlt.Low Voltage r r" , .a r 233/4" I 28 -I Model A B Model A B GMH80453AN* 14" 12'/2" GMH80904BN* 17'/" 16" GMH80703AN* 14" 12'/2" GMH80905CN* 21" 19'/" GMH80704BN* 17'/2" 16" GMH81155CN* 21" 19'/" GMH80903BN 17%" 16" GMH81405DN* 24'/2" 23" * Low NOx model available. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS Sides Rear Front' SW Vent2 B Top 1" 0" 3" 6" 1" 1" ' 24"clearance for serviceability recommended. 2 Single Wall Vent(SW)to be used only as a connector. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA)and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA 8142.2 (in Canada). Note: GMN8 approved for line contact in the horizontal position. 4 www.goodmanmfg.com SS-GMN8 PRODUCT SPECIFICATIONS GDH8 DIMENSIONS ' B r 19 5/8"------1 1111 - Goodman • Low Voltage 39" High Voltage o � 0 A I 11 /8" Alt.Gas Inlet Gas Inle 8 /8° i 233/„ 4 7/16" 1 15/16"--- 28" Model A B Non-Combustible Floor Base GDH80453AXAA 14" 12W SBT14 GDH80703AXAA 14" 12W SBT14 GDH80904BXAA 17'/" 16" SBT17 GDH81155CXAA 21" 19W SBT21 Notes: • Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. • Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details. • Installer must supply the following gas line fittings, according to which entrance is used: 0 Left: One 90°street elbow; one 2'/2' pipe nipple; one 90°elbow; straight pipe; one ground joint union 0 Right: Straight pipe to reach gas valve MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS Sides Rear Front' SW Vent2 B Top 1" 0" 3" 6" 1" 1" ' 24"clearance for serviceability recommended. 2 Single Wall Vent(SW)to be used only as a connector. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ ANSI Z223.1 (in the USA)and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA 8142.2 (in Canada). SS-GMH8 www.goodmanmfg.com 5 PRODUCT SPECIFICATIONS GMH8 BLOWER PERFORMANCE SPECIFICATIONS (CFM & Temperature Rise vs. External Static Pressure) Model Tons AC External Static Pressure, (Inches Water Column) (Heating Speed Motor at 0.5" 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 as Snipped) Speed ESP CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3 1,555 --- 1,511 --- 1,459 --- 1,392 --- 1,344 25 1,279 1,201 1,120 GMH80453AN* Med 2.5 1,165 28 1,123 30 1,100 30 1,090 30 1,048 32 1,017 970 903 (Medium) Med-Lo 2 927 36 907 37 889 37 863 38 853 39 822 800 746 Low 1.5 699 47 694 48 668 50 645 51 636 52 592 566 524 High 3 1,437 36 1,310 39 1,295 40 1,310 39 1,273 41 1,202 1,129 1,039 GMH80703AN* Med 2.5 1,127 46 1,100 47 1,095 47 1,075 48 1,050 49 1,018 967 904 (Medium) Med-Lo 2 895 --- 917 --- 878 --- 867 --- 853 --- 830 786 743 Low 1.5 694 --- 681 --- 663 --- 640 --- 625 --- 591 ,.562:_ 522 High 4 2,234 23 2,151 24 2,076 25 1,990 26 1,897 27 1,803 1,710 1,569 GMH80704BN* Med 3.5 1,676 31 1,653 31 1,648 31 1,581 33 1,555 33 1,492 1,414 1,352 (Medium) Med-Lo 3 1,342 38 1,335 39 1,321 39 1,313 39 1,291 40 1,261 1,215 1,149 Low 2.5 1,089 47 1,085 48 1,078 48 1,071 48 1,057 49 1,040 986 932 High 3 1,593 42 1,561 43 1,567 42 1,543 43 1,493 44 1,420 1,343 1,230 GMH80903BN Med 2.5 1,186 56 1,160 57 1,160 57 1,135 58 1,118 59 1,089 1,045 983 (Medium) Med-Lo 2 957 --- 940 --- 937 --- 921 --- 895 --- 861 826 778 Low 1.5 742 --- 710 --- 685 --- 663 --- 635 --- 611 578 476 High 4 2,182 --- 2,127 31 2,056 32 1,974 33 1,895 35 1,809 1,715 1,588 GMH80904BN* Med 3.5 1,645 40 1,628 40 1,615 40 1,597 41 1,541 43 1,491 1,440 1,350 (Medium) Med-Lo 3 1,320 49 1,305 49 1,310 49 1,310 50 1,295 51 1,267 1,217 1,139 Low 2.5 1,063 60 1,061 60 1,057 61 1,056 61 1,039 61 1,025 1,005 948 High 5 2,334 --- 2,334 --- 2,284 --- 2,135 --- 2,051 35 1,910 1,748 1,605 GMH80905CN* Med 4 1,754 39 1,735 39 1,728 40 1,685 40 1,628 42 1,551 1,469 1,346 (Medium) Med-Lo 3.5 1,367 47 1,380 47 1,371 47 1,374 48 1,335 50 1,293 1,246 1,165 Low 3 1,098 58 1,109 59 1,109 59 1,088 60 1,066 62 1,050 998 916 High 5 2,481 --- 2,395 35 2,288 37 2,217 38 2,076 41 1;999 1,858 1,732 GMH81155CN* Med 4 1,738 49 1,732 49 1,709 50 1,686 50 1,639 52 1,585 1,492 1,385 (Medium) Med-Lo 3.5 1,364 62 1,378 62 1,372 62 1,372 62 1,350 63 1,313 1,261 1;125 Low 3 1,137 --- 1,142 --- 1,140 --- 1,114 --- 1,090 --- 1,056 954 860 High 5 2,554 41 2,435 43 2,375 44 2,240 47 2,152 49 2,002 1,883 1,744 GMH81405DN* Med 4 1,846 57 1,773 59 1,762 60 1,712 61 1,672 63 1,583 1,526 1,442 (Medium) Med-Lo 3.5 1,520 69 1,500 70 1,483 --- 1,470 --- 1,435 --- 1,373 1,308 1,245 Low 3 1,301 --- 1,274 --- 1,260 --- 1,231 --- 1,207 --- 1,177 1,093 931 • Low NOx model available. Notes: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. • For most applications, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • The chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of recommended maximum heating static pressure. • The dashed (----) areas indicate a temperature rise not recommended for this model. • The above chart is for furnaces installed at 0-2000 feet.At higher altitudes, a properly de-rated unit will have approximately the same tem- perature rise at a particular CFM, while ESP at the CFM will be lower. 6 www.goodmanmfg.com SS-GMH8 PRODUCT SPECIFICATIONS GMH8 BLOWER PERFORMANCE DATA CHART w u) - O R - d x 2 - o0. ti U nr' - N I- m - c- U - _ W EFC : \ u_20 - o Wo - O o CC = o d v- D \ o X Q = oo N Oa = _ W o _ rn 0_ = m00 W o I- I- = o _ D o_N O I-- os- - 00 0 Ho y - O D O CD T- F- - o O O _ ti O D - O CO O r _ U - O O O O - Ln O - cP i, , ,i � a ,- O 000 cD Lo d 40 0' M N O.,_ 2SIH 9HnlVH3 JL . SS-GMH8 www.goodmanmfg.com 7 PRODUCT SPECIFICATIONS GDH8 BLOWER PERFORMANCE SPECIFICATIONS (CFM & Temperature Rise vs. External Static Pressure) Model Tons External Static Pressure, (Inches Water Column) (Heating Motor AC at 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Speed as Speed 0.5" Shipped) ESP CFM Rise CFM Rise CFM Rise' CFM Rise CFM Rise CFM CFM CFM High 3.0 1,435 --- 1,421 --- 1,380 --- 1,322 25 1,262 26 1,200 1,144 1,064 GDH8 Med 2.5 1,140 29 1,114 30 1,084 31 1,063 31 1,039 32 1,002 943 897 0453AX (Med) Med-Lo 2.0 899 37 889 37 875 38 871 38 857 39 821 780 745 Low 1.5 691 48 674 49 665 50 651 51 637 52 618 562 525 High 3.0 1,406 37 1,393 37 1,379 37 1,307 39 1,262 41 1,208 1,145 1,070 GDH8 Med 2.5 1,153 45 1,101 47 1,077 48 1,039 50 1,028 50 987 947 885 0703AX Med-Lo 2.0 890 --- 896 --- 873 --- 862 --- 834 --- 798 771 727 (Med) Low 1.5 690 --- 682 --- 664 --- 631 --- 616 --- 583 549 509 High 4.0 2,007 --- 1,993 --- 1,975 --- 1,940 --- 1,844 36 1,770 1,668 1,559 GDH8 Med 3.5 1,612 41 1,606 41 1,570 42 1,533 43 1,501 44 1,448 1,373 1,301 0904BX (Med) Med-Lo 3.0 1,325 50 1,299 51 1,280 52 1,244 53 1,222 54 1,186 1,140 1,079 Low 2.5 1,043 --- 1,040 --- 1,032 --- 1,002 --- 981 --- 955 915 869 High 5.0 2,381 --- 2,312 --- 2,312 --- 2,219 --- 2,134 40 2,024 1,930 1,839, GDH8 Med 4.0 1,801 47 1,667 51 1,667 51 1,638 52 1,613 53 1,513 1,441 1,369 1155CX (Med) Med-Lo 3.5 969 --- 1,062 --- 1,140 --- 1,223 69 1,269 67 1,292 1,322 1,358 Low 3.0 1,100 --- 1,094 --- 1,060 --- 1,031 --- 1,001 --- 953 937 874 Notes: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • The chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of recommended maximum heating static pressure. • The dashed (----)areas indicate a temperature rise not recommended for this model. • The above chart is for U.S.furnaces installed at 0-2000 feet.At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM,while ESP at the CFM will be lower. 8 www.goodmanmfg.com SS-GMH8 PRODUCT SPECIFICATIONS GDH8 BLOWER PERFORMANCE DATA CHART 0 w = - cn - o w o U - Or u o - - O t- T - N I— m - r 25) o W _ _ m = O U _ _____:_=-: \\\ w U O O W p - O O Do N N x _ f- O•N W O N03 _ O m O D u) = LI' \ \(,, ,: o 0 O O 0_ N o o O o i• O CO fl ii Lo O - M — CD O� (0 L� O O O O d• Cr) N 3SIH 3H111VH3dw8l SS-GMH8 www.goodmanmfg.com 9 PRODUCT SPECIFICATIONS GMH8 WIRING DIAGRAM ® SERVIICMG.WIRI�NGTOUNIOTWM SBEBFEORE r- —('-'-27:-3- -)--- ',I!. L7,D... PROPERLY POLARIZED AND GROUNDED. TXFMR(s) ♦1 GNo L ®�GND(S) l HUM OIFIER MVC(9) ®H3 VALVE MVH(12) M�IrlQ ' ::: ^_I^I^I^( I IIO SLOWER1E I3 1E iZ E� % AWPRESSUREu`�`�u u L@LT'''°. OIE SWITCH�% teeOPC' NO ISO SEI. -20,!;,P,,7:;') C 50(a) 6±6 SfiEG ----, '� Y MIOCRO'HL)(]) _- �O(/,,��)y0� \ BR SL a HLO(1) �..' 0(l�:J FJSE ,m,„ .,,,,® �n Z R __ I fRNO.HV scT 4 o ar R02 I t t) cwo ( 3 SEE M1 _ I ' CON1ROi -' AUXILARY , L �, SR LIMITS u AAlJUAL RESET ROLLOUT ULVf CONTfiOL(S) CONTROL lA30LLE Fs a� / \ XFMR(31 ISILE CCNTROLON SONE IlODEiS) rATi p\�3•`�!/� 2a Vnc 6 $ -RD BL T BR � TRANSFORMER 2 I XFMR-H 115 VAC XFMR NI E I . FLAME SENSOR immim- --aI 1 FP HOTSURFAGEER pNT IgIGN •IGH-N fi Pi6,1E s m g D o BK- � 0 171.g' i IND I � BLWR IND.N BK AL=A, /' _�_. HF.Q,O ir y v m COOL II GRCULATOR o )(FUR A /^ I m m _ N N BLWR I CIR-N WH IS V BK J ELECTRONIC GR 15 PIN PLUG EACH \ A_ IR CLEANER 1 EACN 1 ON SOME MODELS V� BLOW ER COMPARTIAENT LINE-H LINE-N ` BURNER COMPARTMENT JUNCTION BOX � 2a VAC DOOR �� /� Y / DOOR SWITCHSWI C ( I �J�, I.�I /m// WITCH LACATED IN BLOWER l'1 5111 p COMPARTMENT ON SOME MODELS J1`;`-=��2 I. T 1 ®WARNING: TI PRESSURE DISCONNECT POWER pISCONNECT RD� A SWITCH BEFORESERVICING. I = PRIMARY LIMIT I L WIRING TO UNiT ' RD MUST eE ( YL PROPERLY YL POLARIZED - ' WI AND GROUNDED. BR BK L 6ND N � TO 1 i SVAC/i H/50 HZ POWER SUPPLY WITH BL = OVERCURRENT PROTECTION DEVICE I I BR BK 1 C HI JUNCTION SHOT 1 2 3 WH BOX _ URFACE 2 STAGE LINE-N IGNITER pA5 VALVE ONO PL/ - MNE H INDUCED DRAFT / BLOWER TO 115 VAC/1/SOH2 PU PU FLAME PITH OWER SUPPLY ROT \\ �5��// SENSOR VERCURRENT PROTECTION ROLLOUT LIMBS DEVICE (SINGLE CONTROL ON SOME MODELS) p STEADY ON=NORMAL OPERATION LOW VOLTAGE(24V) EQUIPMENT GND OFF =CONTROL FAILURE Q FLASH = SYSTEM LOCKOUT(RETRIES/RECYCLES EXCEEDED) LOW VOLTAGE FIELD - - FIELD GND -� A FLASHES=PRESSURE SWITCH STUCK CLOSED HI VOLTAGE(1 i5V) FIELD SPLICE © FLASHES=PRESSURE SWITCH STUCK OPEN HI VOLTAGE FIELD JUNCTION -411- SWITCH(TEMP) °-'5'Q Q FLASHES=OPEN HIGH LIMIT © FLASHES=FLAME SENSE WITHOUT GAS VALVE TERMINAL -Q- IGNITER - — O FLASHES= OPEN ROLLOUT OR OPEN FUSE INTERNAL TO SWITCH(PRESS.) a'�j o Q FLASHES=LOW FLAME SIGNAL INTEGRATED CONTROL OVERCURRENT O RAPID FLASHES=REVERSED 115 VAC POLARITYNERI FY GND PLUG CONNECTION -I J r- PROT.DEVICE COLOR CODES: PK PINK NOTES: YL YELLOW BR BROWN 1.SET HEAT ANTICIPATOR TI ROOM THERMOSTATAT 0.7AMPS. 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. OR ORANGE WH WHITE 3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE PU PURPLE BL BLUE REPLACED,IT MUST BE REPLACED WITH WIRING MATERIAL HAVING ATEMPERATURE GR GREEN GY GRAY RATING OF AT LEAST 105C.USE COPPER CONDUCTORS ONLY. BK BLACK RD RED 4.BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM.(SEE SPEC SHEET FOR AIR FLOW CHAR'T') 5.UNIT MUST 6E PERMANENTLY GROUNDED AND CONFORM TO N.E.C.AND LOCAL CODES. 6.TO RECALL THE LAST 5 FAULTS,MOST RECENT TO LEAST RECENT,DEPRESS SW ITCH 014oF00581 REV. A FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS). Wiring is subject to change. Always refer to the wiring diagram on the unit for most up-to-date wiring. High Voltage: WARNING Disconnect all power before servicing or installing this unit.Multiple power sources --4TZ.41 may be present.Failure to do so may cause property damage,personal injury,or death. likv 10 www.goodmanmfg.com SS-GMH8 PRODUCT SPECIFICATIONS GDN8 WIRING DIAGRAM ® ERVICINGWIRIONGTOUNIDT✓MUSTBERE I_ ico -<HUMIOIFIER �' IeNTROLRODULE PROPERLY POLARIZED AND GROUNDED. XFMR(5) �] GNo GND(H) 24 VAC c2 GAs HUMIDIFIER �MVC(9) J / �IMVH(t2) BHI VALVE [4i190110e ©_ LI MVL(2) � Mt I�mo_} war-- /WRCHRE c G R WY '''.G' © DS(10) C_1.NO C E V-fG ~ `� Y ATO C PSO(4) r� ; ® �-`05E C 0- 4Y 1 MICRO HLI( ) _ ■ © 0 0 HR BL HLO(1) �Vb ©�0 C FJ£E *4 ��[y ,�p ii rxr,IR02f11) /jam CONIKOL ■i■� AUXI4RY ` �.�. HR ILZITS H I R01(5) 0 r CONTROL=1-E ' MUM/4L RE9Ef ROLLOUT LIA1R fANiF101.(s) FS I ' " (SINGLECRN1ROL g150VE1JODELS) yXFMR(3) �2q VAC 40 VA -C .4.= - RD BL a 'I HR ANSFORMER .- %FMR-H 11TR XFMR-N m O 6 "" I FLAlAE SENSOR 1 I HOT SURFACE li IGNITER YFURaI irw- .,. .K:., I . GN • ION-N g p — r. r. 11111111111 BK 3'i TND I • 6LWR INO-N e --,4,,,,, BK 24V • s aoi p COO1.-II CIRCULATOR O • XFMR r Am m L— _ C SH HLWR ICIR-N WH A 0 I - _. BK ,-/ ELECTRONIC GR 15 PIN PLUG EACH ` AIR CLEAN�R I EAGN L ON SOME MODELS ..� O BLOW ER COMPARTMENT • LINE-H LINE-N O BURNER COMPARTMENT 01 }JUNCTION SOX L1 5 R 1 9'' DOOR SWITCH 24 VAC WITCH SWITCH LOCATED LI HLOWER �_-_ �' COMPARTMENT ON SOME MODELS ��������������I/���'''�_�e ®WAR NING: �"�'1' SWEssuRE YL DISCONNECT POWER olscoNNEcr RD �J D� YL rCH BEFORE SERVICING. ' PRIMARY LIMIT WIRING TO UNIT 0 RD MUST BE MUNNYL YL ------ PROPERLY „'11 w POLARIZED _ aK AND GROUNDED. L GND N BR :,•� TO 115VAC/1(d/60 HZ POWER SUPPLY WITH �� el._ . OVERCURRENT PROTECTION DEVICE HR HK MUM PM C HI JUNCT%ON SOT 1 2 3 1Yh ...„asif I URFACE 2 STAGE :72 H N IGNITER OAS VALVE M PLI LINE H INDUCED DRAFT p/\/���{T�\/Q /\/_'��j7{�/\y BLOWER TO 115 VAC/1/00H2 PL. �/ PL' �/ FLAME POWER SUPPLY WITH SENSOR OVERCURREM PROTECTION ROLLOUT LIMITS DEVICE (SINGLE CONTROL ON SOME MODELS) STEADY ON=NORMAL OPERATION LOW VOLTAGE(24V) EQUIPMENT GND �}-j OFF =CONTROL FAILURE LOW VOLTAGE FIELD p FLASH = SYSTEM LOCKOUT(RETRIES/RECYCLES EXCEEDED) FIELD GND © FLASHES=PRESSURE SWITCH STUCK CLOSED HI VOLTAGE(1 i5V) FIELD SPLICE p FLASHES=PRESSURE SWITCH STUCK OPEN HI VOLTAGE FIELD 1 SWITCH(TEMP) d-1� U FLASHES=OPEN HIGH LIMIT JUNCTION © FLASHES=FLAME SENSE W ITHOUT GAS VALVE TERMINAL -Q- IGNITER - — O FLASHES= OPEN ROLLOUT OR OPEN FUSE INTERNAL TO SWITCH(PRESS) 0---5--0 O FLASHES=LOW FLAME SIGNAL INTEGRATED CONTROL OVERCURRENT (-) O RAPID FLASHES=REVERSED 115 VAC POLARITYNERIFY GND PLUG CONNECTION -� 1 ♦•- PROT.DEVICE COLOR CODES: PK PINK NOTES: YL YELLOW BR BROWN 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7AMPS. 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. OR ORANGE WH WHITE 3.IF ANY OFTHE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE PU PURPLE 6L BLUE REPLACED,IT MUST BE REPLACED WITH WIRING MATERIAL HAVING ATEMPERATURE GR GREEN GY GRAY BK BLACK RD RED 4.RALTONWGEROFSAPTEDSSTH1OUSLCD BE EACOPSPTEERD CBONINSUCATLOLRERS ONLY. TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM.(SEE SPEC SHEET FOR AIR FLOW CHART) 5.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.AND LOCAL CODES. 6.TO RECALL THE LAST 5 FAULTS,MOST RECENT TO LEAST RECENT,DEPRESS SWITCH 01 l-0F005B1 REV. A FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS). Wiring is subject to change. Always refer to the wiring diagram on the unit for most up-to-date wiring. High Voltage: ALWARNING Disconnect all power before servicing or installing this unit.Multiple power sources Ul may be present.Failure to do so may cause property damage,personal injury,or death. SS-GMH8 www.goodmanmfg.com 11 PRODUCT SPECIFICATIONS DUAL$AVER CONFIGURATION a OPERATION Dual$aver This furnace is capable of the following heating modes: • Single Stage (Factory Setting) • Modified Two-Stage » Fixed 5-Min Low Stage » Auto Time (1-12 Min) Low Stage To change from the factory single-stage operation, adjust the dipswitches on the ignition control as follows: Off On Mode Mode Dipswitch 5 Min Fixed I EN I 2"d Stage Delay Dipswitch Auto i- Note: This furnace is designed to be used with a single-stage room thermostat. Start Start 1-- Call for Heat Call for Heat r Safety Circuit Check Safety Circuit Check Start Furnace Start Furnace in Low Stage in Low Stage Low-Heat Blower Low-Heat Blower r Delay Time (5 Min) Delay Time (1-12 Min) r Gas Valve Switch Gas Valve Switch to 2nd Stage to 2nd Stage Blower Switch to Blower Switch to Hi Heat Operation Hi Heat Operation T-Stat Satisfied T-Stat Satisfied Goodman Manufacturing Company,LP.,reserves the right to discontinue,or change at any time,specifications or designs without notice ��s or without incurring obligations.©2008 • Goodman Manufacturing Company, L.P. - Houston, Texas • Printed in the USA. 12 www.goodmanmfg.com SS-GMH8 Peoge & Plad'acct2 *eta eaa e€ dot" 11/16/18 ATTN: TJ Company: Town of Vail Job Name: Lorentz Furnace replacement Job Address: 4800 Meadow Drive #23 RE: Scope of work for furnace replacement for 4800 Meadow Drive #23 • Current furnace is short cycling and causing stress on the heat exchanger. • Furnace requires replacement. • Replace existing 80% efficiency with a Goodman GMHB14O5DN 140,000 BTU 80% efficiency single-stage burner multi-speed blower, up flow/horizontal gas furnace. Please see attachment for spec sheets on new unit. • R&H Mechanical will remove old unit from crawl space. • Prep existing area for new unit. Prep floor/hatch to allow new unit to fit in crawl space. • Install new 80% furnace including attachment of current duct work into the new unit. • Install new exhaust pipe into termination. Perform start up and test for proper functions. 1119 Chambers Ave. / P.O. Box 810, Eagle, Colorado 81631 Phone: 970-328-2699/ Fax: 970-328-0234/ Email: info@randhmechanical.com Website: www.randhmechanical.com