HomeMy WebLinkAboutE18-0164 load calcs.pdf 2832 Kinnikinnick Road Unit C
Bolton Residence
Unit Renovation
(6/6/18)
Electrical Load Calculation
(Includes Full Remodel)
Square Footage:
Total Home 1,600'
General Load
1. General Lighting at 3VA per ft. 4800
2. Small Appliance 3000
3. Laundry 1500
4. Oven (50A-240V) 9600
5. Dishwasher 1200
6. Microwave 1000
7. Disposal 1200
8. Dryer (30A-240V) 7200
9. Refrigerator 1200
10. Wall Heater 3800
11. Boiler 600
12. Total 35850
Application of Demand
13. First 10kVA of general load at 100% 10000
14. Remainder of general load at 40% 10340
15. Total 20340
Total Connected Load
20340 Amp/Volts
Total Connected Amps
85 Amps
Existing Service Size
150 Amps