Loading...
HomeMy WebLinkAboutE18-0164 load calcs.pdf 2832 Kinnikinnick Road Unit C Bolton Residence Unit Renovation (6/6/18) Electrical Load Calculation (Includes Full Remodel) Square Footage: Total Home 1,600' General Load 1. General Lighting at 3VA per ft. 4800 2. Small Appliance 3000 3. Laundry 1500 4. Oven (50A-240V) 9600 5. Dishwasher 1200 6. Microwave 1000 7. Disposal 1200 8. Dryer (30A-240V) 7200 9. Refrigerator 1200 10. Wall Heater 3800 11. Boiler 600 12. Total 35850 Application of Demand 13. First 10kVA of general load at 100% 10000 14. Remainder of general load at 40% 10340 15. Total 20340 Total Connected Load 20340 Amp/Volts Total Connected Amps 85 Amps Existing Service Size 150 Amps g-0330 6ioi 6 If