HomeMy WebLinkAboutE18-0254 approved load calcs.pdf, IBI Residential Load Calculation Workshee~ f . Worksheet# 4 1'.>WO OI Vat ~~ (Revised 01 /09/08) f I . WORKSHEET BA: ED ON A STANDARD SERVICE 6l. L l:J: Af I . ~ "·I o\ '10-Q ~~ This ~r shee ~C stand3:d calculatio.n Art. 220.1 thr~ug 220:61) ~\ G~0~, G ,,. 111ay1Je used for a single farmly, two-farmly, or three-farmly dwellmg. o G'l 'v ' r· ?' " / / .v ~<("" .~ / / (;O ~e. \~ "/(. J!/ OJE:This calculation must be used for two-family dwellings. <"J?} ,t,, G IL" ht" L d 431 f '57t1.Uflfl !to& CiA "' enera 1g mg oa Small Appliance Circuits @ 1500 watts ea. (Minimum is 2 per unit) 10500 6000 watts watts I 3 I 4 I s I s 2 Laundry Circuit(s)@ 1500 watts ea. (Minimum is 1 per unit) Total lines 1, 2 & 3 First 3kw of Sub-total General Lighting Load (line 4 above)@ 100% Subtract line 5 from line 4 3000 watts 19500 watts 3000 watts 16500 watts 7 8 11 12 Enter 35% ofline 6 5775 watts Total lines 5 & 7 TOT AL GENERAL LIGHTING LOAD 8775 watts Range and Electric Clothes Dryer Load Refer to the following to determine the range load. When using the Note*, substantiate your calculations using actual nameplate ratings on line 9. Enter the total range loads on line 10. A. One range* (not over 12 KW rating each): Enter 8000 watts on line 10. watts one family two B. One range* (over 12 KW rating each): Enter the sum of 8000 watts plus 400 watts for each KW that the range exceeds 12 KW on line 10. C. Two ranges* (not over 12 KW rating each): Enter 11000 watts on line 10. D. Two ranges* (over 12 KW rating each): Enter the sum of 11000 watts plus 550 watts for each KW that the range exceeds 12 KW on line 10. E. Three ranges* (not over 12 KW rating each): three Enter 14000 watts on line 10. family F. Three ranges* (over 12 KW rating each): Enter the sum of 14000 watts plus 700 for each KW that the range exceeds 12 KW on line 10. watts 11000 watts watts watts watts *Note: For each dwelling unit, the load for a counter-mounted cooking unit and NOT more than TWO wall- mounted ovens may be calculated by adding the nameplate rating of the individual appliances and treating the total as the equivalent to one range. Calculations: TOTAL RANGE LOAD 11000 watts To determine clothes dryer load -enter 5000 watts (or nameplate rating -whichever is larger) for each clothes dryer. Clothes Dryer(s) -Unit 1 5000 watts Clothes Dryer(s) -Unit 2 5000 watts Clothes Dryer(s) -Unit 3 watts TOT AL DRYER LOAD 10000 watts TOT AL RANGE AND DRYER LOAD 21000 watts P.I ;"( • ·. ' ~----. TOTAL QTY IBI Residential Load Calculation Worksheet Worksheet # 4 continued (Revised 01/09/08) FIXED APPLIANCE LOAD (Appliances which are fastened in place). Do not include electric ranges, clothes dryers, or HV AC equipment. Elect. Permit No. Include water heaters, disposals, dishwashers, trash compactors, microwave ovens, etc. List each appliance load separately. (For two and three-family dwellings, list the quantity of each appliance and the sum of the nameplate ratings (in watts) separately): Fixed Appliances DISP TOTAL of ALL units Unit #1 800 Unit #2 800 Unit #3 Fixed Appliances TOT AL of ALL units Unit #1 800 Unit#2 800 Unit #3 Fixed Appliances DW TOT AL of ALL units Unit #1 800 Unit#2 1200 Unit #3 Fixed Appliances TOT AL of ALL units Unit #1 Unit#2 Unit #3 Fixed Appliances MICRO TOT AL of ALL units Unit#1 Unit#2 Unit #3 Fixed Appliances TOT AL of ALL units Unit #1 Unit#2 > Unit #3 Fixed Appliances TOT AL of ALL units Unit#1 Unit#2 Unit #3 Fixed Appliances TOTAL of ALL units Unit#1 Unit #2 Unit #3 ----''--------1 SUB-TOTAL FIXED APPLIANCE LOAD If there are three or less appliances in this section, enter the Sub-Total Fixed Appliance Load on line 13. If there are four or more appliances in this section, enter 75% of the Sub-Total Fixed Appliance Load on line 13, use line below for calculating. * 0.75 = 0.00 TOT AL FIXED APPLIANCE LOAD HVACANDOTHERLOADS TOTAL QTY All loads @ 100% (Volts X Amps= Watts) *Nameplate Heat Pump Compressor Loads TOT AL of ALL units Unit#2 Unit #3 TOTAL of ALL units Unit #3 *Nameplate Air-conditioning Loads TOTAL of ALL units .-"'~~.--~~~~1"."!IMllll!'!l'""~-:---:-1~~~~- U nit #1 Unit #2 Unit #3 ~~~'--~~~--"'- *Nameplate Blower Motor Loads TOTAL of ALL units -----ir------ U nit #2 Unit #3 TOTALHVACLOAD *Where it is unlikely that two or more noncoincident loads will be used simultaneously, it shall be permissible to use only the LARGEST load(s) that will be used at one time for calculating the total load of the service. IBI Residential Load Calculation Worksheet Worksheet# 4 continued (Revised 01/09/08) Other loads @ 100% Elect. Permit No. Examples are sump pumps, sewage pumps, whirlpool motors, attic fans, swimming pool equipment, garage door openers, etc. List each appliance load separately. (For two and three-family dwellings, list the quantity of each and the sum of the nameplate ratings (in watts) separately): Other Load BOILER PUMP TOTAL of ALL units Unit #1 Other Load Unit #1 Other Load Unit #1 Other Load Unit#1 Other Load Unit #1 Other Load Unit #1 Other Load Unit #1 Other Load Unit#1 200 Unit#2 200 Unit #3 TOT AL of ALL units Unit#2 Unit #3 TOT AL of ALL units Unit#2 Unit #3 TOT AL of ALL units Unit#2 Unit #3 TOTAL of ALL units Unit#2 Unit #3 TOT AL of ALL units Unit#2 Unit #3 TOT AL of ALL units Unit#2 Unit#3 TOTAL of ALL units Unit#2 Unit #3 TOT AL OTHER LOADS HVACandOTHERTOTALLOADS CALCULATE THE SERVICE LOAD TOT AL GENERAL LIGHTING LOAD TOTAL RANGE AND DRYER LOAD TOTAL FIXED APPLIANCE LOAD TOTAL HV AC AND OTHER LOADS TOTAL LOAD 400 watts 400 watts 8775 watts 21000 watts 5200 watts 400 watts 35375 watts TOTAL LOAD Service Voltage = Minimum Service Ampacity 35375 watts 240 volts = 147.40 amps