Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-0040_A1.2.pdf
ll tz 4,7 00 eb I I {F1111--1 I I I III II I I I I I I 44, ' lei ' 03/ 9/17 BEDSr 1 BED #5 VICTOR MARK DONA L DSON -II 101 101 lr 7 [❑1 [❑1 OPEN TO BELOW OPEN TO BELOW ,_ _ , r-- F O UN T =0 UNT = O , BES #3r _______ BE» #5 BATH #5 / BATH #3 i i / o] Q ARCHITECTURE � �- � X � PLANNING __, cal ito INTERIORS OPEN TO BELOW OPEN TO BELOW O \ SINCE 1977 (4 (D) (D) 0^I) 0 ARCHITECT S = STORAGE = e _ e = STORAGE — 0 — _ — _ Q — � 4111 ° ----- UTILITY � UTILITY ° � 90 VI BENCHVARKROAD tUNT � T � 5 , SUITE 207 - I I LJ� �1 BOX 5300 BATH #� ` z z\/ / 1E3ATI-1 #� - — — — - - — — — AVON , CO 81620 H H II H — FLASHING DETAIL NOTES: 4 Uo' Peo I I 910 . 949 . 5200 �/ 2 X , I I • ALL HIDDEN FLASHING SHALL BE MINIMUM 26 GAGE GALVANIZED METAL. Lt i i Lt i • ALL EXPOSED FLASHING SHALL BE 26 GAGE RECLA, RE: SPEC. c h r i s j@ v m d a. c 0 m �` (w) (D) (D) (w) I I I I I • 2015 IBC, 1403.10.12.1 FLASHING AT FOUNDATION. A CORROSION RESISTANT SCREED OR FAX 949 . 5 2 0 5 fill CI _ I I FLASHING OF A MINIMUM 0.014 INCH OR 26 GAGE GALVANIZED OR PLASTIC WITH A MINIMUM STORAGE = o e = STORAGE U U U U VERTICAL ATTACHMENT FLANGE OF 3 INCHES SHALL BE INSTALLED TO EXTEND NOT LESS THAN I INCH BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD HALLS IN �- . ° UTILITY UTILITY ° ACCORDANCE WITH SECTION 1405.4. THE WATER RESISTIVE BARRIER SHALL LAP OVER THE C C O EXTERIOR OF THE ATTACHMENT FLANGE OF THE SCREED OR FLASHING. �i jJ •-2015 IBC, 1405.10.1.3 CLEARANCES. ON EXTERIOR SW WALLS, ADHERED MASONRY VENEER '% — — _ {TT i. © SHALL BE INSTALLED NOT LESS 4 INCHES ABOVE THE EARTH, OR NOT LESS THAN 2 INCHES 4 VI TOR C?\ — ABOVE PAVED AREAS, OR NOT LESS THAN,L INCH ABOVE EXTERIOR WALKING' SURFACES ARK e -..„ ARCHEDI I I I ARCHED THAT ARE SUPPORTED BY THE SAME FOUNDATION THAT SUPPORTS THE EXTERIOR HALL. * 0 D 1 I I 00FN I I 0 0 I I I 0 0 I I ISI u EXTERIOR GOLORS $ 4/ v I ISI I ' LEVEL � LA\ set) AIRc\\ I I CoT SCALE: I / 4" = II - 0" MATERIALS LEGEND O 0 00 ,,. NEW GEMENTITIOUS STUCCO SYSTEM (TYP), RE: SPEC O = STUCCO SYSTEM NOT TO BE REMOVED, INTEGRATE W.R.B. OM W/ NEW STUCCO SYSTEM, APPLY STO RESTORE (FINISH 4 REPAIR) OVER STUCCO TO REMAIN (TYP.), RE: SPEC O NEW HOOD SIDING: RE: SPEC. H domM1 ; w V O NEW 2X6 RS CEDAR HOOD TRIM, RE: DETAILS 4 SPEC. L j 0 i Al--11 _-----„/ u u m U T = U T T O5 NEW,bXb RS CEDAR COLUMNS, RE: STRUCTURAL z Ln �, J co O NEW,6x12 DOUG-FIR RIDGE BEAM, RE: STRUCTURAL = 0 = 0 zop O NEW,6x12 DOUG-FIR HEEL BEAM,RE: STRUCTURAL L .1: I 0 0 J LDa NEW,6x12 DOUG-FIR ARCHED BEAM, RE: DETAIL $ O D Q � I 1 STRUCTURAL C= CC U < > FURR OUT WALL AT STONE, RE: LL ,6X12 HEEL BEAM ELEVATIONS, DETAILS $ STRUCT ,6X12 BEAM 6X12 HEEL BEAM O EXISTING ROOF TO BE REPLACED BY OWNER, GOORD. 1.1J 1 NEW STANDING FLASHING TIE-IN AT WALL /CHIMNEY H J .Z NEW STANDING SEAM ROOF X �, Q SEAM ROOF ARCHED — to NEW METAL STANDING SEAM ROOF, BY OWNER L LJ O ARCHED ,6)S6 HOOD ,6Xb HOOD II NEW 2" STONE VENEER, (RE: SPEC.) OVER EXISTING FRAME 1111:C COLUMN BELOW COLUMN BELOW HALL, W/2" STONE GAP, RE: DETAIL EAVE OF ROOF ,6X12 ARCHED BEAM ,6X12 ARCHED BEAM EAVE OF ROOF 1' ] L � J �/ O NEW?,6 6A REGLA BASE FLASHING, RE: SPEC. 4 DETAILS L J I3 NEW METAL CHIMNEY CAP, RE: SPEC.. 4 DETAIL 14 REPLACE STAIR STRINGERS (RE: STRUGT.), TREADS 1B3 [U] 0 ILDHIKIG O (GRIPSTRUT PROVIDED BY OWNER), HANDRAIL (MATCH p H pliEXISTING) 4 4" SLAB W/TURNED DOWN EDGE, RE: STRUCT. p) [jiJ H _ 15 NEW STAMPED CONCRETE OVERLAY OVER EXISTING SLAB u lb NEW 2" STONE VENEER, (RE: SPEC) OVER NEW OK COLUMNS, CURVED GLULAM BEAM CURVED 6LULAM BEAM OC COPYRIGHT (RE: STRUCT) 11/4" STONE CAP, RE: DETAIL ©COPYRIGHT Mark Donaldson OI� BALUSTERS: RE: DEMO PLANS Architects AllllRights ETAIL E NTR( ROOF FLAB II� Is Reserved (79 NEW STAMPED CONCRETE SLAB, RE: STRUCT. SCALE: I /2" -- I' - 0" ENTRY ON EAST SIDE SIMILAR la NEW 2x8 RS CEDAR BELLYBAND, RE: DETAILS SPEC. REVISION CI EXISTING SLABS TO REMAIN;NO WORK U.N.O. NO STAMPED CONCRETE. CI NEW ROOF TO WALL FLASHING, RE: DETAILS, NOTES 4 SPEC. DATE 03/14/2017 CI FURR OUT HALL AT STONE, RE: ELEVATIONS, DETAILS 4 STRUCT. JOB NO. 1610 GENERAL NOTES ALL SOFFITS AT ENTRIES SHALL BE IX6 T4G BLUE STAIN PINE 2ND LEVEL ALL CRAWLSPACE VENTS TO REMAIN FLOOR PLAN REMOVE 4 REPLACE ALL DRYER $ BATHROOM VENTS, RE: SPEC. SHEET NO. A1 .2