HomeMy WebLinkAbout20181004145544634.pdf - D3
Bit /7
THUNDER MOUNTAIN TESTING
2970 N. Ronlin Avenue / Grand Junction, Colorado 81504
Office (970) 256-9965 / Cell (970) 210-7008 / Fax (970) 314-7067
E-Mail: kxkid39@aol.com / www,thundermountaintesting.com
Lions Mane HOA • September 18, 2018
1116 Sandstone Drive
Vail, CO 81657
ATTN: Mr. Lou Bainbridge
RE: 1116 Sandstone Drive Permit#B18-0347
Vail, CO 81657 Job#1807-11
*Field Inspection
Dear Mr. Bainbridge,
As requested, structural steel special inspection was conducted per the IBC 2015
Edition - Chapter 17: Structural Tests and Special Inspection and the Town of Vail
requirements. I arrived on site at 11:30 AM. I met with Darrell Lundholm with R A
Nelson to review material ready for inspection.
Visual welding inspection was conducted on the steel joist welding repairs
utilizing approved drawings provided by KRM Consultants, Inc.: Drawing#S1-
Joist/Deck Repair issued 8/17/18. I observed %2"plug welds in the 2"C-channel every 8"
and the flare bevel welds on the replaced round bar in the end of the joist. Inspection was
conducted on a total of 29 joist repaired in this section. Upon completion, all welds were
in compliance with the project specifications and the visual requirements as stated in
Clause 6 of the AWS Dl.l Welding Code- Steel: 2015 Edition.
Continued inspection at a later date.
Respectfully Submitted, Rev' w,-e by,
Daniel i. Bricker � dtt'L. f'
AWS CWI#09052051 AWS CWI#91040201
Thunder Mountain Testing ICC Certified #0863569-S1 .& S2
ASNT NDT Level III #30242
Dan 1 BrickerTh +der • . taro Testing
CW1 0°x"+.,...2051 .f••n L Maxwell
• OC1EXP5flI2O2I v��� 191040201
C 1 EXP.4/1/2021
•
&r- 0 34 7
THUNDER MOUNTAIN TESTING
2970 N. Ronlin Avenue / Grand Junction, Colorado 81504
Office (970) 256-9965 / Cell (970) 210-7008 / Fax (970) 314-7067
E-Mail: kxkid39@aol.com / www.thundermountaintesting.com
Lions Mane HOA September 24, 2018
1116 Sandstone Drive
Vail, CO 81657
ATTN: Mr. Lou Bainbridge
RE: 1116 Sandstone Drive Permit#B18-0347
Vail, CO 81657 Job#1807-11
*Field Inspection
Dear Mr. Bainbridge,
As requested, structural steel special inspection was conducted per the IBC 2015
Edition - Chapter 17: Structural Tests and Special Inspection and the Town of Vail
requirements. I arrived on site at 9:15 AM. I met with Darrell Lundholm with R A Nelson
to review material ready for inspection.
Visual welding inspection was conducted on the second section to the east for the
parking spaces on the steel joist welding repairs utilizing approved drawings provided by
KRM Consultants,Inc.: Drawing#SI- Joist/Deck Repair issued 8/17/18. I observed Y2"
plug welds in the 2" C-channel every 8"and the flare bevel welds on the replaced round
bar in the end of the joist. Inspection was conducted on a total of 29 joist repaired in this
section. Upon further inspection, I observed a number of plug welds not filled as required
and most of the round bar replacements for the joist repair were not chipped of slag. I
brought this to the attention of Mr. Lundholm and marked the plug welds requiring
repairs. Re-inspection shall be conducted upon repair completion
Continued inspection at a later date.
Res ectfully Submitted, Rev.- d by,
4/Ae
Daniel I. Bricker - ons . M I
AWS CWI #09052051 AWS CWI#91040201
Thunder Mountain Testing ICC Certified #0863569-S1 & S2
ASNT NDT Level III #30242
• Dan.I Bricker Thunder Mountain Testing
CWI 09052051 . •tt L Maxwell
QC1 EXP. 5/1/2021 r:
►• C 191040201
�' ¢C1 EXP.41//2021
&t- D 317
THUNDER MOUNTAIN TESTING
2970 N. Ronlin Avenue / Grand Junction, Colorado 81504
Office (970) 256-9965 / Cell (970) 210-7008 / Fax (970) 314-7067
E-Mail: kxkid39@aol.com / www.thundermountaintesting.com
Lions Mane HOA September 27. 2018
1116 Sandstone Drive
Vail, CO 81657
ATTN: Mr. Lou Bainbridge
RE: 1116 Sandstone Drive Permit#B18-0347
. Vail, CO 81657 Job#1807-11
*Field Inspection
Dear Mr. Bainbridge,
As requested, structural steel special inspection was conducted per the IBC 2015
Edition - Chapter 17: Structural Tests and Special Inspection and the Town of Vail
requirements. I arrived on site at 9:15 AM. I met with Darrell Lundholm with R A Nelson
to review material ready for inspection.
• Visual welding.inspection was conducted on the second section to the east for the
parking spaces on steel joist welding repairs utilizing approved drawings provided by
KRM Consultants, Inc.: Drawing#S1-Joist/Deck Repair issued 8/17/18. I observed %2"
plug welds in the 2" C-channel every 8"and the flare bevel welds on the replaced round
bar in the end of the joist. Inspection was conducted on a total of 29 joist repaired in this
section. This is a re-inspection of my report dated 9-24-2018. All of the previously
marked plug welds were correctly filled and the joist end bars were chipped as required.
Upon completion, all welds were found to be in compliance with project specifications
and the visual inspection requirements as stated in Clause 6 of the AWS D1.1 Welding
Code-Steel: 2015 Edition.
Respectfully /Sub tte/, Re/vi s by,
--4 i /
,c_,2(/,1L J ' * t ,/ter', / //.
Daniel I.Bricker / co�� . :► .i!
AWS CWI #09052051 AWS C I#91140201
Thunder Mountain Testing ICC Certified #0863569-S1 & S2
ASNT NDT Level III#30242
<>
Cantil Thunder Mountain Testing
CWI 09062051
GIC1 EXP. 5/1/2021I i*� tt 91040201
Maxwell
QC1 EXP.4/1/2021