HomeMy WebLinkAboutB18-0490_Approved Documents_1540913078.pdf 75 South Frontage Road Construction
0West, TOWN OF VAIL B18-0490
h Vail,CO 81657 Issued: 10/30/2018
TOWN OF VAIL „ Office:970.479.2139
Inspections:
inspections@vailgov.com
Property Information
Address: 1116 SANDSTONEDR 102 (210301410002102)(210301410002 )
Unit#: 102
ParcelNumber: 210301410002
LegalDescription: DESC: PK SP 4 Subdivision:LIONS MANE CONDO Unit:102
Contacts
ContactType: Applicant
Full Name: Linda Petrocchi
Address: 255 WyandotSt.255 WyandotSt.Denver,CO 80223 Phone: 3037773234
ContactType: PropertyOwner
Full Name: PAUL J. KIRBYREVOCABLE TRUSTPAULJ. KIRBY,TRUSTEE
Address: Phone: None
Contractor
Contractor Type: General
Company: Colorado ComfortProducts, Inc
State License#: Phone: 303-777-3234
Projectinformation
ProjeciName: KirbyResidence2018
ProjeclDescription: Remove old fireplace insert&install new Mendota D-40 gas insert.40,000 BTU's Intertek testedto ANSI
Z21.44-1995
Fees Paid
AccounP:001-0000.31111.00 -MechanicalPermitFee FeeAmount: $80.00
A ccounP:001-0000.31123.00 MechanicalPlan ReviewFee FeeAmount: $20.00
Account#:001-0000.31128.00 Will Call Fee(Mechanical Scope) FeeAmount: $5.00
TotalPaid: $105.00
Conditions
CONDITIONS UNDERWHICH PERMITS BECOME VOID:
If construction is not begun within6 months from the date permitwas issued.
Ifmorethan5 months elapses betweeninspections.
If incorrectinformationis given on the applicationat thetime the permitwas issued.
ChristopherJarecki-Townof Vail Building Official
NOTICE:Byissuance ofthis Permittheapplicantagreesto complywithall Titlesofthe Townof Vail Code and all applicableStateand Federal
law.Failureto do so will void this Permitand the applicantshallforfeitall applicablefees.
°I1111
PERMIT FEE RECEIPT
TOWN OF VAIL Case # B 18-0490
Date Printed: 10/29/2018
TOWN OF VAIL - FEES RECEIPT
Permit Summary
Case Number: B18-0490 Status: Created
Permit Number: Date Started: 10/26/2018
Permit Type: Construction Subc ases Multi-Family
Lot Number: A5
Property: 1116 SANDSTONE DR 102 (210301410002 102) (210301410002)
Contacts
Contact Type: Applicant
Company Name: Colorado Comfort Pds.lnc
Full Name: Linda Petrocchi
Address: 255 Wyandot St.255 Wyandot St. Denver,CO 80223
Email: linda@1ccp.com
Contact Type: Property Owner
Full Name: PAUL J. KIRBY REVOCABLE TRUST PAUL J. I,
Address:
Permit Fees
Fee Information Account Amount
Permit Fee 001-0000.31111.00 $80.00
Plan Review 001-0000.31123.00 $20.00
Will Call Fee 001-0000.31128.00 $5.00
Payment Information Date Paid Payment Type Amount
Will Call Fee 10/29/2018 Credit Card $5.00
Paid By: -Notes:VISA-DAVID HALL
Permit Fee 10/29/2018 Credit Card $80.00
Paid By: -Notes:VISA-DAVID HALL
Plan Review 10/29/2018 Credit Card $20.00
Paid By: -Notes:VISA-DAVID HALL
FEE TOTAL $105.00
AMOUNT PAID $105.00
BALANCE DUE $0.00
75 South Frontage Road West,Vail,Colorado 81657 10/29/2018 -3:36:48 PM-Generated by:cgodfrey
1/1
MENDOTA "SEABROOK'
DIRECT VENT
GAS FIREPLACE INSERT
WITH
HEARTHGLO COMBUSTION SYSTEM
Model D-40 Dee 1 Timber:Flat or Ba
1
J.
(D40 Flat shown with optional Andover Door and Overlay)
INSTALLATION & OPERATING INSTRUCTIONS
PIATIONAI. We recommend that our gas NO.DT-0806
INSTITUTE hearth pro
ucts be installed
ill and serviced by profes-
sionals who are certified in V�
the U.S.by the National a ��n
Fireplace Institute INFO as
CE D w NFI Gas Specialists. once
varardlootted
WARNING:TATS APPLIANCE TO BE USED ONLY AS AN INSERT IN AVERTISSEMENT:Cet appareil a etre employe seulment comme un inserer dans
SOLID FUEL BURNING FIREPLACES. lecarburant solide brulaut des cheminees.
INOTE:THE NATURAL VENT(B-VENT)SYSTEM CANNOT BE USED TO VENT THIS INSERT MODEL! I
WARNING: This product must be installed by a licensed plumber or gas fitter when installed in the commonwealth of Massachusetts. improper installation,
adjustment,alteration,service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional Information consult a
qualified installer,service agency or the gas supplier.
FOR YOUR SAFETY:DO NOT STORE OR USE GASOLINE OR OTHER POUR VOTRE Securitd:Nc pas entreposer ni utiliser d'essence ni d'autre vaperures ou liquides
FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY inflammables dans le voisinage de yet appareil ou de tout autre apparel].
OTHER APPLIANCE.
FOR YOUR SAFETY:WHAT TO DO IF YOU SMELL GAS: POUR VOTRE Securite:One faire si.roma sentez une odour de gaz:
1.OPEN WINDOWS. 1.Ne pas tenter d'allumer d'sppareil
2.DON'T TOUCH ELECTRICAL SWITCHES. 2.Ne touchez is aucun interrupleur.Ne pas Vous servir des tele phones so trouvant dans le bad-
3.DO NOT USE ANY PHONE IN YOUR BUILDING merit ou vous Nous trouvez
4.EXTINGUISH ANY OPEN FLAME 3.Evacuez to piece,le bOtimeat au la zone.
5.IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE. 4.Appelue iesmediatement votre fournisseor de au depuis unvoisiu.Soivee les instructions du
6.FOLLOW THE GAS SUPPLIERS INSTRUCTIONS. fournisser.
T.IF GAS SUPPLIER IS UNAVAILABLE,CALL YOUR FIRE DEPARTMENT. 5.Si vous ne poovez rejoindre le fournisseur de gas,appelez le service dos iaceudies.
WARNING:IMPROPER INSTALLATION,ADJUSTMENT,ALTERATION, AVERTISSEMENT:Une installation.un reglage,rine modification,un corrodes on une maime-
SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY nance incorrects peuveut entrainor des dommages materiels,des lesions corporelles ou hi ports de
DAMAGE. REFER TO THIS MANUAL.FOR ASSISTANCE OR ADDITIONAL vies humnines_Consuter le mantle{des usagers fours avec ce geaerateurd'air chaad.
INFORMATION,CONSULT A QUALIFIED INSTALLER,SERVICE AGENCY,
OR THE GAS SUPPLIER.
MISE EN GARDE:Installation,reglage,modification,entretiea ou depannage non appeepries pourront causer des blessures ou des dommages materiels.R6terez•vous flu manuel du
proprietaire fourni avac vet apparieL Pour assistance ou renseignements complemenmi res,vetdl]ez consulter an installateur experiment€,une agents de depannagelentreitieu au cotre
Compagnie valise.Pour utilisation aver les portes en verve vertifile Pepperell suelement Ne pas operer awe le verrlere enterer.cragaeture,besot.
TABLE OF CONTENTS
SPECIFICATIONS 1
CONGRATULATIONS, 2
GENERAL INFORMATION 3
ELECTRICAL REQUIREMENTS 3
SPECIFICATIONS&CLEARANCES 4
INSTALLATION INSTRUCTIONS 6
FLUE VENTING 7
RAISED HEARTH SPECIFICATIONS 14
GAS SUPPLY REQUIREMENTS 15
GAS PRESSURE REQUIREMENTS 16
INSTALLATION CHECK OFF LIST 16
LIGHTING CHECK OFF LIST 17
LIGHTING INSTRUCTIONS 18
DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS 20
WALL SWITCH,REMOTE CONTROL OR THERMOSTAT OPERATION 28
BLOWER OPERATION AND WIRING 29
BLOWER(S)REMOVAL 30
CUSTOMER INFORMATION AND TROUBLE-SHOOTING 31
TROUBLE SHOOTING MENDOTA GAS FIREPLACE INSERT 32 •
GAS FLAME ADJUSTMENT 32
MAINTENANCE 33
REPLACEMENT PARTS LIST 34
NATURAL TO LP GAS CONVERSION 35
"LABEL REPRESENTATION" 37
MENDOTA WARRANTY QUALIFICATION&SERVICE REFERENCE FORM 38
MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY 42
SPECIFICATIONS
MODEL D-40 DEEP TIMBER
High Fire- Adj.to- Low Fire
BTUH NAT.GAS 40,000 6,500
BTUH L.P.GAS 39,000 ---- 6,500
A Natural Gas to LPG conversion kit#HA-34-00178 must be purchased separately to burn LPG.—SEE Pg 35
MAIN ORIFICE REAR BURNER:32"NAT.GAS[1/16"L.P.GAS]—FRONT BURNER:#48 NAT.[#57 LP]
OVERALL EFFICIENCY EXCEEDS D.O.E.EFFICIENCY REQUIREMENTS(A.F.U.E.)
FLUE VENT LINER CO-LINEAR-4"DIAMETER EXHAUST&4"DIAMETER INLET or
CO-AXIAL -4"DIAMETER EXHAUST&6"DIAMETER INLET
NET WEIGHT 195 lbs.
SAFETY AGA CERTIFIED PILOT GENERATOR,MILLIVOLT SYSTEM
ACTIVATED WITH SWITCH,REMOTE CONTROL OR THERMOSTAT.
GAS REQUIREMENTS SUPPLY PRESSURE: GAS INLET: 3/8"N.P.T.
NAT.GAS: 7"W.C. [5.0"W.C.MIN.,11"W.C.MAX.]
L.P.GAS: 11"W.C. [11"W.C.MIN.,13"W.C.MAX.]
ELECTRICAL REQUIREMENTS 120 Volts AC,2 Amps
LISTINGS INTERTEK TESTING SERVICES TESTED TO:ANSI Z21.11.1-1993&CAN1-2.I M89"GAS-FIRED VENTED
ROOM HEATERS"&CAN/CGA 2.17-M91"GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES",ANSI Z21.44-1995
"GAS-DIRECT VENT WALL FURNACES"AND CGA INTERIM REQUIREMENT#41-M91"DIRECT VENT GAS
FIREPLACES"AND UL307B"MOBILE HOME,APPROVED EXCEPT RECREATIONAL VEHICLES"
Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American National
Standards Institute-ANSI Gas Appliance Safety Standards. For more information see Pg.37. The Mendota Gas Fireplace
Insert has been tested and certified by Intertek Testing Services.8431 Murphy Drive,Middleton,WI 53562.
INSERT INCLUDES HEARTHGLO COMBUSTION SYSTEM,DUAL ROT AIR BLOWERS,6-PIECE CERAMIC FIBER LOG SET&COALS,NEO-
CERAM GLASS,PIEZO IGNITER AND AGA CERTIFIED SAFETY SYSTEM.
OPTIONS:BLACK OR BRASS GRILL SETS,BLACK OR GOLD FILIGREE FRONTS,BLACK ARCHED DOOR KITS(ANDOVER),3 SIZES OF
SURROUNDS&2 TYPES(CO-LINEAR OR COAXIAL)OF VENTING KITS.
1
SPECIFICATIONS&CLEARANCES
34
h-24 1
I I 16114
<„A113 114
TOP VIEW
B IN.MIN.CLEARANCE
MANTEL
(mss`=1
r u
12"MIN.
FROM TOP TRIM
OF GRILL B
TO MANTEL D-40 Surround Dimensions
A
1 � Inches mm. Inches mm.
31 788 44 1118
A No Trim 33 838 48 1220
243/4 36 914 52 1321
With Black or 311/16 792 441/8 1122
it r" Brass Trim
331/16 843 481/8 1224
36
FRONT VIEW 361/16 920 52 1/8 1326
FIGURE 2: 0-40 Surround Dimensions
8"MAX.MANTEL
DEPTH(WIDTH)
518
13 114
rr 4-6 COAX ADAPTER
CO–AXIAL VENT ADAPTER
24518
22 314
19 I
16" MIN. NON—COMBUSTIBLE
HEARTH EXTENSION
5
MENDOTA D-40 GAS DIRECT VENT FIREPLACE INSERT
SPECIFICATIONS&CLEARANCES
34 -
1 24 f
16114
111Wi'
13 114
TOP VIEW
81N.MIN.CLEARANCE
MANTEL
1
q
I U
12"MIN.
FROM TOP TRIM
OF GRILL I 13 �� D- 40 Surround Dimensions
TO MANTEL A B
-LT _._ Inches mm. Inches nun.
_ No Trim 31 788 44 1118
33 838 48 1220
24 3/4 A 36 914 52 1321
1 With Black 31 1/16 792 44 1/8 1122
or Brass
Trim 331/16 843 481/8 1224
i 36 361/16 920 521/8 I326
FRONT VIEW
— 8"MAX.MANTEL
DEPTH(WIDTH)
7-
5/8
13 1/4
4-6 CO-LINEAR ADAPTER
......t__Tr
ill P 24 518
22 3/4
�
—a I 1 16"MIN. NON-COMBUSTIBLE
HEARTH EXTENSION
CO-LINEAR VENT ADAPTER
MENDOTA D-40 GAS DIRECT VENT FIREPLACE INSERT
4
FLUE VENTING
10. The 13-40 Insert must be vented vertically to the outside and must use the Mendota flexible ducting system.
There are two methods for venting Mendota Direct Vent Inserts:1)Co-Axial and 2)Co-Linear
. — 45-01-00069 VERTICAL VENT CAP
NgNOT SUPPLIED WITH KIT
4....--45-01-00153 FLASHING/CAP ADAPTER
-------- ----------
4" EXHAUST 1�
INSULATION i 6" INLET
Nit 50-06-00073 CLAMP
IV I d 45-01-00124 CO—AX DIRECT
VENT ADAPTER
lri— 1111
I VENT 00378 COAXIAL,
VENT KIT
-,.. .....! „op..
FIGURE 3
CO-AXIAL VENT KIT (Typically for factory built ZC fireplaces.)
NOTE: THE INSERT IS DESIGNED,TESTED AND LISTED FOR OPERATION ONLY WITH MENDOTA
INSERT VENTING COMPONENTS AS LISTED IN FIGURES 3,3A,4&4A.
g 45-01-00069 VERTICAL VENT CAP
fI'1I
NOT SUPPLIED WITH KIT
- 45-01-00153 FLASHING/CAP ADAPTER
;-ter_
iti 'lc/1i •—3 %
�.iiiii �i � %r
PI
.11
I�Ri�iV�//j
4" EXHAUST --•
`l�� / 50-06-00073 CLAMP
5-01-00123 DIRECT VENT
ADAPTER BOOT
ONir, AA--11-0377 CO—LINEAR
°� 1 o VENT KIT
�► I4lf q
FIGURE 3A
7
12. Attach a sheet metal strap loop to the flex end of the liner(s)and tie a rope to it. Two installers should
proceed to the roof and drop the rope(with weight on the end to make sure it goes all the way down)and in-
sert the liner(s)past the flexible portion,into the existing chimney[See FIGURE 5].
NOTE: Repeat this step for second liner on chimneys 9"and larger.
�APPROVED FLUE LINER
J%///I�� 0
r� I� APPROVED FLUE LINER �) ` I- ail
cl : f -1 I I: ,: `�
�17 t_ opo
SHEET METAL -1
STRAP LOOP be*Leilm re
EXISTING 2lm
FIREPLACE ] ='
LINER .0
Il
_I [ ROPE 0I 1
, I
L.
fAM 11.1,I, :I \
mw r
I o lt.'
D.V. BOOT ADAPTER o,�
qI. O • r . .I, I:
WEIGHT
x_ ' , , iM ROPE
" . , . -ANA
FIGURE 5
13. One installer should then return to the fireplace opening and pull the rope to guide the liner(s)into place
through the smoke shelf and the damper opening to a point 20"(508 mm)above the fireplace hearth
[See FIGURE 5]. It may be necessary for the person on the roof to turn the liner slightly to avoid mortar
chunks and misaligned tiles. The person below should wear leather gloves and Safety Glasses during this
process to avoid being cut and to safeguard eyes from flying debris.
CAUTION: WHEN USING FLEX ALUMINUM LINER,USE EXTREME CAUTION WREN STRETCHING
LINER AROUND OFFSETS SO AS NOT TO RUPTURE LINER.
9