HomeMy WebLinkAboutE18-0211 Approved Plans.pdf . i/ ; roSt2
,•:. • .
. co =
LU N
LT1 .0
" . I W o w
'L
0 %
i OZ
di > WQ
O U lam_ .
i ,
uE
4IL ?A<tstut. i 6cOQcO8
AIdA 11 - u,j rr lc
t $' 3 11 etg' 0-- e) ( (
$( is)oko.AL riicAtt4 .
iLi.ftfl...1 .v.lk,svek.N I Isrub4A. , I ,c,r 474 4-,
Ix 3 ILEL-rttc gos Ba D. Q 4; i1, Z
t '
(„,/, II frieni .4,1
-it- y30- --
"r- 1 /t< 1
35 ,
< rICI _ � l� 4
1 ' ' _-
6NORALIGHTING•
NHRIC-17QAT / NHRIC-17QNBAT Type
•
Project
6" IC Air-Tight Line Voltage Remodel Housing Catalog No.
Source: 100W Max. (Varies with trim) Lamp/Wattage
PRODUCT DESCRIPTION DIMENSIONS
Remodel housing for use in existing sheet rock,insulated ceilings can be in direct contact11111116
with thermal insulation.Air-tight construction provides energy savings by reducing the flow
of air through the ceiling. I �1; , r ®0
FEATURES 7-12^ _•6-3/4" (I)
• Rated for direct contact with insulation I
• cULus listed for damp location and through branch circuit wiring L
• Quick connect provided
• Installation-ready for existing sheet rock ceilings i_6-sir I 13-3F1•-�
• Accommodates 1-3/8"maximum ceiling thickness Gelling Cut-out
CONSTRUCTION Cut-out: 6-3/8" HousingLength:13-3/4"
Housing
0.040 aluminum adjusts to a maximum ceiling thickness of 1-3/8"(35mm).Housing ID: 6" Housing Width: 7- "
terminates at 1/4"ceiling flange for even positioning of housing angle within the ceiling. Housing Height 7-11/2/2"
Structural arm consisting of 0.050 structural steel connects housing with junction box.Fixture •
may be installed in areas where it will have direct contact with thermal insulation. L&bels and Listings
cULus Listed for Damp Location w/Feed Through
Air Row Restriction cULus Wet Listed(Only with designated trims)
Housing has factory installed gaskets to restrict airflow from room into ceiling plenum to Meets or exceeds ASTM-283 Air-Tight Requirements
<2CFM(cubic feet per minute)in accordance with ASTM-283 Air-Tight requirements. Washington State Approved
Socket NYC Approved:Calendar#43895
NHRIC-17QAT:
Galvanized steel socket plate adjusts inside housing for optimum light performance.Contains c®Bs AIA.
a single medium base socket.Protective cap included to protect socket interior during ceiling
LISTED iTIiKT
painting.Socket plate can be removed in the field to convert to a floating socket
NHRIC-17QNBAT:
Socket is free floating and installs to eyeball,gimbal ring and new trims equipped with socket
brackets.Protective cap included to protect socket interior during ceiling painting.
Mounting
Four high tension springs secure the housing to an existing sheet rock ceiling.
Accommodates ceiling thickness to 1-3/8"(35mm).
Junction Box
Plaster frame integrated 15 cu.in.junction box 0.064 galvanized steel with five 1/2",two
3/4"knockouts,and four Romex®pryouts.Electrical grounding automatic when feeding with
grounded steel EMT pipe or flex.Green wire provided for installations with ground wire fed
through PVC pipe conduit.
Quick Connect Feature
Housing contains three UL approved quick connections that allow insertion of 1/4"stripped
solid or tinned standard conductors to be inserted into the connector.Connectors are pre-
attached to fixture power,common,and ground circuits.
Thermal Protector
Standard UL thermal protector rated for 90°C is affixed to inner top surface of housing.
Lamp
100W max.-lamp and wattage varies with trim(ordered separately)
Housings
NHRIC-170AT:6"IC Air-light Line Voltage Remodel Housing,Adjustable Socket Bracket
NHRIC-17QNBAT:6"IC Alr-Tight Line Voltage Remodel Housing,Floating Socket(No Bracket)
11111
r 5 NORA LIGHTING® 6505 Gayhart st..Commerce,CA►9oow 1 of 1
wwwnoralighting.com • Specifications subject to change without notice. ®2011
Phone:800.686.6672 • FAX:800.500.9955 • e-mail:nora@noralighting.com Page
ELT OL (
* TENMAT
Technical Product Specifications
Model Inside Inside
MODEL FF109-300 Number Height Diameter
FF109-300 7 3/8" 13"
. : ... . . '.14,25, .
Performance Data
: :6 .- .. •
For Use:
13' • Classified to maintain the fire rating(1 hour)for the
• following fire rated floor/ceiling assemblies:
UL L500 series
i •
4111,
0.'
• U 1
i .. :
' 1 •
• CLASSIFIED FOR FIRE RESISTANCE
FIRE RESISTANCE CLASSIFICATION
SEE UL FIRE RESISTANCE DIRECTORY
0•.., FF109-300 DOME 0
w General Information
e
Benefits:
• 60 minute protection.
1
'� 5/8' • Fits most popular IC rated fixtures.
• Can be used in L500 floor/ceiling assemblies.
• Lightweight(approx. 1.5 lbs).
• Easy Installation-can be fitted in seconds-no screws,
;... .. . . drilling or additional sealant required.
: .: • Flexible material enables cover to be fitted around
a obstacles or retro-fitted.
.,. .. •..:;. :::.•.` :•. • Enhances the acoustic protection of the ceiling.
.
lOttatlon Hotes
"
• Reduces heat loss through the fixture.
• .. ' ; • • Significant energy cost savings.
1 _.."-1
t '
• Maintenance free.
. • . . , Manufactured By
F
:- ..:: Tenmat Inc
E!:600
.!:::!:::::::.
. • .. • . .... Fax: (302) 633-6838
Email: info@tenmatusa.com
www.tenmatusa.com
U 1- D).( (
1111.11.—
> . TAM LITE MODEL: TYPE
rnmuTE
=I LIGHTING PROJECT:
PREPARED BY: DATE:
SERIES SPECIFICATIONS RFK56 SERIES
The RFK56 is a 5/6"LED Retrofit Kit constructed with
a one piece die cast aluminum body.This retrofit is a
specially designed trim which functions as a heat sink. It
is supplied with 2 torsion springs accommodating most /
5/6"Recessed housings.
Orik
OD «L lig AIR 3E14R
,......, LED Ramie nOff
LISTED
LINE DRAWING
AI 1 21
v r
r"1---013,-1 L,)? /4'7"--""1
CONSTRUCTION
Housing Thermal Management
Aluminum Specially designed trim functions as a heat sink
• Mounting Style Accomodates
Torsion spring Most 5"and 6"standard and shallow housings
Retrofit Connector LED Driver
-, E26 medium screw-base Built-in Potted Electronic Driver
Lens Material
Polycarbonate
ELECTRICAL SPECIFICATIONS
- Input Voltage Dimming Recommended dimmer
120-277VAC 5-100% Electronic low voltage
APPLICATION AND PERFORMANCE SPECIFICATION INFORMATION IS SUBJECT TO CHANGE WITHOUT NOTIFICATION
rrimure
660 NW PEACOCK BLVD. PORT ST. LUCIE, FL 34986 TEL: 772.879.0178 !, TAMLITEUSA.COM
_,(g— odtl
��rAmre,
TAM LITE MODEL: TYPE
LIGHTINGG PROJECT:
PREPARED BY: DATE:
ELECTRICAL SPECIFICATIONS(Cont.)
CRI Input Wattage Input Current
>80 15W 0.15A
Frequency Fixture Efficacy Operating Temp.
50-6OHz 8OLM/W -20°-+40°C
1111
LED Lifespan Color Temp Storage Temp.
50000 H rs 3000K -40°C-+80°C, 10-90%RH
1.
Output Voltage Output Current Lumens
20-29VDC 0.35A 12O0Lm
Driver Efficiency Beam Angle Power Factor
84% 96.1° >=0.9
LED Quantity LED Efficacy
18 11OLM/W
*Please consult factory for list of approved dimmers
PHOTOMETRIC ISOLINES
TAMLITE LIGHTING DELUCE �'''�/�/��� Polar Graph
- RFK563 �1t ,/, I Maximum Candela=554.17
Horizontal Footcandles , `,�I'''�� Located at Horizontal Angle=270
Scale:Hash=10 Ft. �� Vertical Angle=5
1 1 (Y.':--i al . 1 1 Light Loss Factor=1.00 .. Vertical Plane Through Horizontal
Lumens Per Lam 1229 Angles
Total Lamp Lumens=1229 '�• �`•� (270 90)
Mounting Height=10 Ft • � ,,1` �,`./ Horizontal Cone Through Vertical
_ Maximum Calculated Value=5.43 Fc � , ,, '/ Angle
Arrangement:Single #.- 4 MO (5)
WAPPLICATION AND PERFORMANCE SPECIFICATION INFORMATION IS SUBJECTTO CHANGE WITHOUT NOTIFICATION
UTE
ll 660 NW PEACOCK BLVD. PORT ST. LUCIE, FL 34986 TEL: 772.879.0178 TAMLITEUSA.COM
rRmure
-474k
TAM LITE MODEL: TYPE
�.� LIGHTING PROJECT:
PREPARED BY: DATE:
CERTIFICATIONS/WARRANTY
Listing Location Rating:
UL,C-UL Listed Suitable for wet locations
ASTM
Certified under ASTM-E283 for Airtight Construction
Warranty
Guaranteed three years from the purchase date of the product,against mechanical defects in manufacturing.
I
ORDERING INFORMATION
Sample Part Number:RFK56-3
Carton Dimensions: 19.05x19.05x10.16CM Case Dimensions:40.64x41.91x33.02CM
7.5x7.5x4IN 16x16.5x131N
Carton Weight: 1.25 Lbs Case Weight: 15.9 Lbs
Case Quantity: 12 PCS
RFK56
SERIES COLOR TEMP FINISH
RFK56 [-3]:3000K [BLANK]:White
[-4]:4000K
NOTES
This unit can only be considered IC rated if used in approved IC rated housing.
Input Driver 120-277v:120v Dimming only
WrnAPPLICATION AND PERFORMANCE SPECIFICATION INFORMATION IS SUBJECT TO CHANGE WITHOUT NOTIFICATION
"= 1111&„ 660 NW PEACOCK BLVD. PORT ST. LUCIE, FL 34986 TEL: 772.879.0178 TAMLITEUSA.COM