Loading...
HomeMy WebLinkAboutE18-0061_2018-03-15_Slifer Square For Construction Set-Stamped 21_1525274013.pdf M a 4 NEW 800 AMP 208 VOLT,3-PHASE 'F-11207 A. CT CABINET PER HCE 62 SPACE PANELBOARD,WITH 400 BrightView REQUIREMENTS AMP MAIN CIRCUIT BREAKER. Design Group 05/02/18 WATER FEATURE EQUIPMENT SCHEDULE \LiiNEW UTILITY METER, 1645 Grant Street HOUSING BY EC, METER BY HOLY CROSS Denver,Colorado 80203 MARK DESCRIPTION VOLT/ HP WATTS FLA MCA MOCP STARTER DISCONNECT/ FEEDER SPECIFIC NOTES ENERGY. PANEL T/303.825.2010 PHASE FUSE SIZE 'SP1' / n FP-1 FILTER PUMP 208/3 3 17 20/3 3-#12,#12 GRD. ) 1 I Brightview.com 3/4"C / DP-1 DISPLAY PUMP 208/3 5 28 40/3 3-#8,#10 GRD.1"C \ CONSULTANTS CIVIL e STRUCTURAL ENGINEERING SP-1 SUMP PUMP 120/1 1/3 7 20/1 2412,#12 GRD. Martin/Martin 3/4"C #1/0 GRD. 0101 Fawcett Road, Ste 260 EXISTING LIGHT AND POLE TO BE REMOVED, ELECTRODE Avon I Colorado 81620 EF-1 VAULT EXHAUST FAN 120/1 750 20/1 2412,#12 GRD. SALVAGED, CLEANED,AND REMOUNTED ON NEW 3/4"C POLE BASE. 970.926.6007 UV-1 UV FILTER 208/3 2000 40/3 4-#8,#10 GRD.3/4°C SITE SURVEYING GENERAL NOTES: Gore Range Surveying 3/4"X 8'GROUND 5129 Longsun Lane ROD Avon I Colorado 81620 A. SEE SPECIFICATIONS FOR ELECTRICAL DIVISION AND MECHANICAL DIVISION MOTOR STARTER COORDINATION. 970.479.8698 B. FOUNTAIN CONTRACTOR TO PROVIDE CONTROL PANEL WHICH CONTAINS STARTERS AND CIRCUIT BREAKER. C. PROVIDE ALL EXTERIOR DISCONNECTS WITH NEMA 3R RATING. Z — MECHANICAL e ELECTRICAL ENGINEERING D. WHEN EQUIPMENT IS LISTED WITH ONLY A HORSEPOWER RATING THE DISCONNECT AND FEEDER ARE SIZED PER THE N.E.C. BG MECHANICAL BuildingWorks SPECIFIC NOTES: 222 Chapel Place, U nit (1) EXISTING SECONDARY FEEDER TO Avon I Colorado 81620 AC 201 (2) BE RECONNECTED. PROVIDE NEW 970.949.6108 CONDUITS. REFER TO SHEET E1.0. (3) FOUNTAINDESIGN (4) 12'-0" Waterline Studios 605 Colombia Rd. E L E CT R I CA L O N E-LINE DIAGRAM Fort Collins I Colorado 80525 PANEL: SP1 VOLTAGE: 120/208V, 3PH, 4W 970.207.9697 IRRIGATION DESIGN MINIMUM BUS: 600 El I SCALE: NONE HydroSystems LOCATION: ELECTRICAL CLOSET MAIN: 400/3 CB ` ' 860 Tabor Street,Ste 200 MOUNTING: SURFACE MINIMUM AIC: 22,000 Lakewood I Colorado 80401 303.980.5327 NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER LOAD TYPE LOAD DESCRIPTION NO. A B C POLE TRIP A B C TRIP POLE A B C MOUNT DEVICE BOX TO A OWNER 1 7978 E + 20 1 L FOUNTAIN LIGHTS 2 4X4"TREATED WOOD POST. 3 7978 E + 20 1 L (E)MEADOW DR.LIGHTS 4 5 7978 E WATER FEATURE CONTROL + 20 1 L (E)PUMP VAULT LTS. 6 Town of Vail 7 E PANEL(2) 2 100 + 20 1 L (E)SLIFER PLAZA LTS. 8 GROUND LUG. � / g GFCI DUPLEX RECEPTACLE WITH a 75 South Fronto e Road 9 - E + 20 1 R (E)SLIFER PLAZA POLE REC. 10 WEATHER PROOF(IN USE) aQo 11 E + 20 1 A (E)BUS SHELTER SIGNAGE 12 VailI Colorado 81657 970.479.2337 13 R (E)CLOSET RECEPT. 1 20 + 20 1 R (E)BUS SHELTER RECEPT. 14 COVER AND DIE CAST ALUMINUM 15 L (E)BRIDGECLOSELIGHTS 1 20 + 20 1 L MOUNTING AND LEVELING BOLT FS BOX. - (E)BUS SHELTER LTS. 16 PER MANUFACTURER'S Lil 17 (E)BRIDGE HEAT TRACE(1) 1 20 + 20 1 R (E)COVERED BRIDGE REC. 18 u /_____ 19 500 L (E)WALKWAY LIGHTS 1 20 + _ip20 1 L (E)BRIDGE LIGHTS 20 > SPECIFICATIONS. CONDUITS 21 500 L (E)WALKWAY LIGHTS 1 20 + 20 1 L (E)WALK PATH PHOTOCELL 22 r Ce 23 500 L (E)WALKWAY LIGHTS 1 20 + 20 1 E IRRIGATION CONTROLLER 500 24 / L PROVIDE NEW POLE BASE,PER NOTES; 25 750 R S.E.RECEPTACLES 1 20 + 20 1 R S.E.RECEPTACES. 750 26 \ A / d r TOV STANDARD, FOR EACH LIGHT �/ COORDINATE EXACT LOCATION /r 0 27 750 R S.E.RECEPTACLES 1 20 + 20 1 R S.E.RECEPTACES. 750 28 1 Q a POLE SHOWN ON PLAN. C OF THE RECEPTACLE WITHIN \` 10 29 750 R S.E.RECEPTACLES 1 20 + 20 1 R S.E.ARECEPTACES. 750 30 =VIII as aI I m VIII— �� l\ /�\ /� O PLANTER WITH THE TOWN OF ED / VAIL. o' O 31 SPARE 1 20 20 1 SPARE 32 O O EIE O El) O El) O 33 SPARE 1 20 + 20 1 SPARE 34 la ELECTRICAL CONDUIT. 35 SPARE 1 20 + 20 1 SPARE 36 37 SPARE 1 20 + 20 1 SPARE 38 q ° �j' s . 7411)0 4111)0 411.4111)0 C O 39 SPARE 1 20 + 20 1 SPARE 40 1 a� 41 SPARE 1 20 + 20 1 SPARE 42 r� 43 + 44 4 —� I I i4 ' II ' (::::) (::::) (::::) 47 45 + 46+ 48 ' ( ,� J° I (4)-#5 VERTICAL REINFORCED O O O O• W J 49 + 50 I I 1 ° 2"MIN. CLR. �� �� �� LL 51 + 52 1" ° °1° Q 53 + 54 ,..1_,_' I J PLANTER BOX 55 + 56 \ i � a #3 CLOSED TIES AT 1' 0" / )1F / 57 + 58 C C I O.C.2" MIN. CLR. N 59 + 60 61 + 62 FEED THRU FEEDER GENERAL NOTES: 20' BARE#6 COPPER WIRE PLANTER RECEPTACLE MOUNTING DIAGRAM LOAD TYPE PANEL TOTAL TOTAL SUBFEED TOTAL SUBTOTAL DEMAND FEEDER TOTAL / _ A. EXISTING LOAD TO REMAIN TO BE RE-CONNECTED. (L)LIGHTING 1500 1500 125% 1875 B. 2'—O" GROUND COIL. (R)RECEPTACLES 4500 4500 NEC 220 4500 C. NO SCALE 0 (LM)LARGEST MOTOR 0 0 25% 0 D. (M)MOTORS(ALL) 0 0 100% 0 E. (E)EQUIPMENT 24434 24434 100% 24434 SPECIFIC NOTES: t/�] LIGHT POLE DIAGRAM (A)APPLIANCES 0 0 0 0 (1) PROVIDE 30mA GFCI CIRCUIT BREAKER PANEL TOTAL(KVA): 30.8 (2) INCLUDE ONLY IN BID ALTERNATE C SIGNATURE �t SEAL 3) SCALE: NONE �'!!,,l.."''� i+ Syp �� PANEL TOTAL(A): 86 (4) ,I} pO �� { �� (5) 1 '.. ' LSSA..{ D� r`0 G ti A • 12 • • I REVISIONS 0 0 o N W 0 0 0 U-) 1-- 0) co U' z NO. COMMENTS DATE Q r:C 0 SHEET INFORMATION O DATE 01/12/2018 0 J JOB NUMBER 113360 DRAWN BY MAS co CHECKED BY MAS Q a w FOR CONSTRUCTION w rI D 0 U) CC LU w_ U) ELECTRICAL N- SCHEDULES a7 co @ BU I L D 0 N GWORKS 0w O systems fulfilled CC 303.278.3820 wwwb buildin workscom d Project No.9756.00 Copyright 2016 CD 00 ALBUQUERQUE I AVON I DENVER I FORT COLLINS Copyright 2014 BrightView Design Group