Loading...
HomeMy WebLinkAboutE17-0169_E17-0169 load calcs_1503524040.pdfA-Phase Electric, LLC Berger Residence Load Calculation 5166A Black Gore Drive General Lighting and Receptacle Demand Load: 3600 sq. ft. x 3VA = 10800 1,500 VA x 2= 3000 1,500 VA x 1 = 1500 Total connected load: 15,300 3,000 VA @ 100% = 3,000 VA @ 35% = 4,305.0 1506.75 Total general lighting and Receptacle demand load: 4,507 Range demand load: 12,000VA 8,000 Dryer Load: 5,000 Fixed appliance load: Dishwasher 1.2 kva 1 1,200 Microwave 1.8 kva 1 1,800 Garbage disposal .8 kva 1 800 jetted tub 1800 0 0 coffee system 1800 0 0 humidifier 1800 0 0 toto toilet 1600 0 0 elevator 5000 0 0 Sub-Zero 1.2 kva 1 1,200 A/C 5000 0 0 Hot tub 12000 1 12,000 Total fixed appliance load: 17,000 08/23/17 A-Phase Electric, LLC Berger Residence Load Calculation 5166A Black Gore Drive Heating load: Boiler 0.2 1 200 Pump 0.2 1 200 heat tape 6 200 1,200 Infrared heat 0 0 0 Total heating load: 1,600 25% of largest motor: 1,200 Totals: General lighting and receptacles: 4,507 Range: 8,000 Dryer: 5,000 Fixed appliance: 17,000 Heating: 1,600 25% of largest motor: 1,200 Total: VA 37,307 AMPS 179.36 Installed Service Size: 200A single phase 08/23/17