Loading...
HomeMy WebLinkAboutVVMC Pipe Fittings.pdfSchedule 10 and Schedule 40 A company 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail: info@bullmoosetube.com For additional information, contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation.02/03 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube’s Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. Schedule 10 Pipe Nominal Pipe Size (in) O.D. (in) I.D. (in) Nom. Wall (in) Weight/Ft Bundle Size 1 1-1/4 1-1/2 2 2-1/2 3 4 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.097 1.442 1.682 2.157 2.635 3.260 4.260 0.109 0.109 0.109 0.109 0.120 0.120 0.120 1.40 lbs/ft 1.81 lbs/ft 2.08 lbs/ft 2.64 lbs/ft 3.53 lbs/ft 4.33 lbs/ft 5.62 lbs/ft 91 61 61 37 30 19 19 Schedule 40 Pipe Nominal Pipe Size (in) O.D. (in) I.D. (in) Nom. Wall (in) Weight/Ft Bundle Size 1 1-1/4 1-1/2 2 1.315 1.660 1.900 2.375 1.049 1.380 1.610 2.067 0.133 0.140 0.145 0.154 1.68 lbs/ft 2.27 lbs/ft 2.72 lbs/ft 3.65 lbs/ft 70 51 44 30 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer’s instructions for the specific fitting used. Wheatland’s Schedule 10 Sprinkler Pipe is a high quality sprinkler pipe offering you the full range of assurances you require. Schedule 10 Sprinkler Pipe has passed some of the toughest lab tests ever created for sprinkler pipe. Wheatland’s schedule 10 Sprinkler Pipe is made from the highest quality steel in one of the nation’s most modern and most complete pipe manufacturing plants. Our proprietary mill coating offers you a clean, corrosion and heat resistant surface that outlasts and outperforms standard lacquer coatings. Plus, this coating can be quickly and easily painted without special preparation. Or it may be hot-dipped galvanized to meet FM requirements for dry systems in accordance with the zinc coating specification of ASTM A795 or A53. Wheatland’s Schedule 10 Lightwall Sprinkler Pipe meets or exceeds the following: • UL Listed • FM Approved • ASTM A135, Grade A Schedule 10 Sprinkler Pipe snoitacificepS SPN D.OlanimoND.IlanimoNllaWlanimoNthgieWlanimoN *RRCLU seceiP tfiL .nimm.nimm.nimm.tf/.sblm/gk 4/11066.12.24244.16.63901.77.218.196.23.716 2/11009.13.84286.17.24901.77.290.211.38.516 2573.23.06751.28.45901.77.246.239.37.473 2/12578.20.37536.29.66021.50.335.362.55.303 3005.39.88062.38.28021.50.343.464.66.291 4005.43.411062.42.801021.50.326.573.86.191 5365.53.141592.55.431431.04.387.785.115.131 6526.63.861753.65.161431.04.303.958.310.101 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Schedule 40 steel pipe is used as the benchmark (value of 1.0). Please refer to appropriate documentation for up-to-date listing and approval information. Specifications and descriptions are accurate as known at time of publication and are subject to change without notice. Wheatland’s Made in the U.S.A. by Wheatland Tube Com- pany means made to the highest standards for consistant quality. Specifications and Approvals 900 Haddon Avenue, Collingswood, NJ 08108-2162 Ph 800.257.8182 Fax 856.854.0616 www.wheatland.com Wheatland Tube Company 0705 1.0M Wheatland Tube Company 900 Haddon Avenue Collingswood, NJ 08108-2162 800.257.8182 www.wheatland.comWheatland ASTM A 53 Schedule 40 Pipe Wheatland Steel Pipe is made by specialists who understand that it’s the small details that make the difference between average products and superior products. At the Wheatland Plant, most department heads and foremen have been employed in some phase of pipe manufacturing for 25 or more years. This kind of specialization, experience and knowledge pays off...in workable, threadable, uniform pipe. Delivered clean. Delivered promptly. Wheatland specializes in manufacturing welded steel pipe in 1/2 through 4 nominal sizes. Available inventory in 1/8 to 12 pipe sizes produced to various ASTM standards is maintained to meet your pipe requirements. Care, pride and personal concern are bonus features that go into every inch of Wheatland Pipe. Don’t settle for less. Make sure it’s quality. Make sure it’s Wheatland. Standard Pipe Schedule 40 Product Type and Specification: Standard welded pipe is produced in 1/2 to 6 trade sizes. Wheatland pipe is produced to ASTM A 53, A 501, and A 589 Type II, API 5L and Federal Specification WW-P404. All pipe threads conform to ANSI B1.20.1. Merchant couplings comply with ASTM A 865. SPN rotangiseD ND rotangiseD edistuO retemaiD edisnI retemaiD llaW ssenkcihT htgneLtinurep)ssaM(thgieWlanimoN )sehcnI()mm()sehcnI()mm()sehcnI()mm(dnEnialP )tf/bl( dnEnialP )m/gk( &sdaerhT sgnilpuoC )tf/bl( &sdaerhT sgnilpuoC m/gk( 8/16 504.03.01962.08.6860.037.142.073.052.073.0 4/18 045.07.31463.02.9880.042.234.036.034.036.0 8/301576.01.71394.05.21190.013.275.048.075.048.0 2/151048.03.12226.08.51901.077.258.072.168.072.1 4/302050.17.62428.09.02311.078.231.196.141.196.1 152513.14.33940.16.62331.083.386.105.296.105.2 4/1-123066.12.24083.11.53041.065.372.293.382.204.3 2/1-104009.13.84016.19.04541.086.327.250.447.240.4 205573.23.06760.25.25451.019.366.344.586.364.5 2/1-256578.20.37964.27.26302.061.508.536.858.576.8 308005.39.88860.39.77612.094.585.792.1186.753.11 2/1-309000.46.101845.31.09622.047.521.975.3172.917.31 4001005.43.411620.43.201732.020.608.0170.6129.0132.61 5521365.53.141740.52.851852.055.636.4177.1209.4170.22 6051526.63.861560.61.451082.011.799.8162.8243.9185.82 8002526.81.912189.77.202223.081.885.8255.2453.9237.34 01052057.010.372020.015.452563.072.925.0492.0694.1463.36 epiPdradnatS 211 003057.218.323000.218.403573.025.916.9487.3782.1512.67 etoN1 .04eludehcston,epipllawdradnatsroferasnoisnemid21SPN Wheatland ASTM A 53 Schedule 40 Pipe The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining. The coupling’s unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems. LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe Size cULus/FM VdS LPCB NominalSizeInches/mm Sch. 5psi/KPa Sch.10psi/kPa Sch. 40psi/KPa psi/kPa psi/kPa 1¼175 365 365 365 36532120625172517251725171½175 365 365 365 3654012062517251725172517 2 175 365 365 365 3655012062517251725172517 2½N/A 365 365 365 365 65 2517 2517 2517 2517 76.1 mm N/A N/A 365**365 3652517**2517 2517 3 N/A 365 365 365 365802517251725172517 108 mm N/A 365***365***N/A N/A2517***2517***4 N/A 365 365 365 3651002517251725172517 133 mm N/A 290***365***N/A N/A1999***2517*** 139.7 mm N/A N/A 290**232 365 1999**1600 2517 165.1 mm N/A N/A 290**232 3651999**1600 2517 6#N/A 290 365 232 365150#1999 2517 1600 2517 * Listed/Approved for wet and dry pipe systems (> –40°F/–40°C). Please refer to the Victaulic Installation Manual (I-009H_009_009V.pdf) for details concerning when supplemental lubrication is required. ** EN-10219(L) for 76.1mm size; EN-10255(M) # Regional availability only# *** FM Approved only. 10.61_1 FireLock EZ® Rigid Coupling STYLE 009H 10.61IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS JOB/OWNER CONTRACTOR ENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G PATENTED SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS LISTINGS/APPROVALS * Speciality Pipe Pipe Size Pressure Rating – psi/kPa Pa Pipe Size Pressure Rating – psi/kPakPa Pipe Size Pressure Rating – psi/kPa/kPa Sch.Inches cULus FM Sch.Inches cULus FM Sch.Inches cULus FM BLT 1 1/4 – 2 300 3002068 EZT 1 1/4 – 2 3002068 3002068 MT 1 1/4 – 2 3002068 30020682068 DF 1 1/4 – 4 300 3002068 FF 1 1/4 – 4 3002068 3002068 MLT 1 1/4 – 2 N/A 30020682068 DT 1 1/4 – 2 300 3002068 FLF 1 1/4 – 4 N/A 3002068 ST 1 1/4 – 2 N/A 300 20682068 EF 1 1/4 – 4 175 1751206 FLT 1 1/4 – 2 N/A 3002068 STF 1 1/4 – 4 N/A 30020681206 EL 1 1/4 – 2 300 3002068 FLTL 1 1/4 – 2 N/A 3002068 TF 2 1/4 – 4 N/A 30020682068 ET40 1 1/4 – 2 300 3002068 GL 1 1/4 – 2 3002068 3002068 WLS 1 1/4 – 2 3002068 30020682068 EZF 3 – 4 300 3002068 MF 1 1/4 – 4 3002068 3002068 WST 1 1/4 – 2 N/A 17512062068 XL 1 1/4 – 2 3002068 3002068 Note: The Specialty Pipe table only applies to imperial sizes, NOT to metric sizes. 10.61_2 FireLock EZ® Rigid Coupling STYLE 009H 10.61IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G STYLE 009H DIMENSIONS X ZY STYLE 009H PRE-ASSEMBLED (PUSH ON CONDITION) X ZY STYLE 009H JOINT ASSEMBLED Size Max. Work.Press. * Max. EndLoad * Allow. Pipe EndSep. †@ Bolt/NutNo. – Size Dimensions – Inches/mm Aprx.Wgt. Ea. NominalSizeInchesmm ActualOutsideDia.Inchesmm psikPa Lbs.N Inchesmm Inches Pre-assembled(Stab in condition)Joint Assembled Lbs.kgXYXYZ 1 1/4 1.660 365 790 0.10 2 - 3/8 x 2 2.95 4.77 2.70 4.63 1.93 1.43242.4 2517 3514 2.54 - M10 x 2 75 121 69 118 49 0.7 1 1/2 1.900 365 1035 0.10 2 - 3/8 x 2 3.19 4.97 2.94 4.79 1.93 1.54048.3 2517 4604 2.54 - M10 x 2 81 126 75 122 49 0.7 2 2.37 5 365 1616 0.12 2 - 3/8 x 2 3.79 5.53 3.45 5.42 1.93 1.95060.3 2517 7193 3.05 - M10 x 2 96 140 88 138 49 0.9 2 1/2 2.875 365 2370 0.12 2 - 3/8 x 2 1/2 4.29 6.09 3.92 5.85 1.93 2.16573.0 2517 10542 3.05 - M10 x 2 1/2 109 155 100 149 49 1.0 76.1 mm 3.000 365 2580 0.12 2 - 3/8 x 2 1/2 4.40 6.31 4.05 5.90 1.93 2.1 76.1 2517 11476 3.05 - M10 x 2 1/2 112 160 103 150 49 1.0 3 3.500 365 3512 0.12 2 - 3/8 x 2 1/2 4.91 6.70 4.55 6.46 1.93 2.38088.9 2517 15622 3.05 - M10 x 2 1/2 125 170 116 164 49 1.0 108 mm 4.250 365 5178 0.17 2 - 3/8 x 2 1/2 5.56 7.61 5.27 7.51 2.14 2.8108.0 2517 23030 4.32 - M10 x 2 1/2 141 193 134 191 54 1.2 4 4.500 365 5805 0.17 2 - 3/8 x 2 1/2 5.95 7.82 5.54 7.47 2.14 2.9100114.3 2517 25822 4.32 - M10 x 2 1/2 151 199 141 190 55 1.3 133 mm 5.250 365 7900 0.17 2 - 3/8 x 2 1/2 6.66 9.11 6.36 9.01 2.14 4.3133.0 2517 35140 4.33 - M10 x 2 1/2 169 232 162 229 55 1.9 139.7 mm 5.500 365 8620 0.17 2 - 3/8 x 2 1/2 6.75 9.29 6.46 9.23 2.09 4.6139.7 2517 38340 4.32 - M10 x 2 1/2 172 236 164 234 53 2.1 165.1 mm 6.500 290 9623 0.17 2 - 5/8 x 3 1/4 7.84 10.93 7.55 10.85 2.11 5.69165.1 1999 42805 4.32 - M16 x 3 1/4 199 278 192 276 54 2.6 6 6.625 290 9997 0.17 2 - 5/8 x 3 1/4 7.96 11.08 7.67 11.99 2.11 5.92150168.3 1999 44469 4.32 - M16 x 3 1/4 202 281 195 305 54 2.69 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See page 1 of this document for Listed/Approved ratings on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 ½ times the figures shown in the chart on page 1, specific to pipe schedule and size. † The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. 10.61_3 FireLock EZ® Rigid Coupling STYLE 009H 10.61IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: • Orange enamel (North America, Asia Pacific) • Red enamel (Europe) Optional Coatings: • Hot dipped galvanized Gasket: • Grade “E” EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009H couplings, use FireLock No. 006 end caps containing the “EZ” marking on the inside face or No. 60 end caps con- taining the “QV EZ” marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling. There is no interchanging of gaskets or housings between coupling styles. GENERAL NOTES INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. USE OF FLUSHSEAL GASKETS FOR DRY PIPE SYSTEMS FireLock EZ couplings are supplied with FireLock EZ Grade “E” Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. 10.61 FireLock EZ® Rigid Coupling STYLE 009H 10.61IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS For complete contact information, visit www.victaulic.com 10.61 5731 REV G UPDATED 09/2012 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel. • Optional: Hot dipped galvanized and others. Gasket: (specify choice*) • Grade “E” EPDM EPDM (Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade “T” nitrile Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air over +140°F/+60°C and water over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. MATERIAL SPECIFICATIONS 06.05_ Flexible Coupling STYLE 75 06.05CARBON STEEL PIPE – GROOVED COUPLINGS JOB/OWNER CONTRACTOR ENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. . REV_J Exaggerated for clarity SEE VICTAULIC PUBLICATION 0.0 FOR DETAILS VNIIPO DIMENSIONS Size Max. Work Pressure *Max. End Load *Allow. Pipe End Sep. †Deflect. Fr. CL†Bolt/Nut@ No – Size Dimensions – Inches/mm Approx. Wgt. Each Nominal Size Inchesmm Actual Outside Diameter Inchesmm psi kPa Lbs.N Inches mm Per Cplg. Deg. Pipe In./Ft.mm/m Inches X Y Z Lbs. kg 1 1.315 500 680 0 – 0.06 2˚ – 43’0.57 2 – 3/8 x 2 2.38 4.27 1.77 1.32533.4 3450 3025 0 – 1.6 48 61 108 45 0.6 1 1/4 1.660 500 1080 0 – 0.06 2˚ – 10’0.45 2 – 3/8 x 2 2.68 4.61 1.77 1.43242.2 3450 4805 0 – 1.6 38 68 117 45 0.6 1 1/2 1.900 500 1.420 0 – 0.06 1˚ – 56’0.40 2 – 3/8 x 2 2.91 4.82 1.77 1.54048.3 3450 6320 0 – 1.6 33 74 122 45 0.6 2 2.375 500 2.215 0 – 0.06 1˚ – 31’0.32 2 – 3/8 x 2 3.43 5.22 1.88 1.75060.3 3450 9860 0 – 1.6 26 87 133 48 0.8 2 1/2 2.875 500 3.245 0 – 0.06 1˚ – 15’0.26 2 – 3/8 x 2 3.88 5.68 1.88 1.96573.0 3450 14440 0 – 1.6 22 98 144 48 0.9 76.1 mm ‡3.000 500 3.535 0 – 0.06 1˚ – 12’0.26 2 – 3/8 x 2 4.00 5.90 1.88 1.976.1 3450 15730 0 – 1.6 22 102 150 48 0.9 3 3.500 500 4.800 0 – 0.06 1˚ – 2’0.22 2 – 1/2 x 2 3/4 4.50 7.00 1.88 2.98088.9 3450 21360 0 – 1.6 18 114 178 48 1.3 3 1/2 4.000 500 6.300 0 – 0.06 0˚ – 54’0.19 2 – 1/2 x 2 3/4 5.00 7.50 1.88 2.990101.6 3450 28035 0 – 1.6 16 127 191 48 1.3 4 4.500 500 7.950 0 – 0.13 1˚ – 36’0.34 2 – 1/2 x 2 3/4 5.80 8.03 2.13 4.1100114.3 3450 35380 0 – 3.2 28 147 204 54 1.9 108.0 mm 4.250 450 6.380 0 – 0.13 1˚ – 41’0.35 2 – 12 x 70.0 5.55 7.79 2.13 3.7108.0 3100 28395 0 – 3.2 29 141 198 54 1.7 4 1/2 5.000 450 8.820 0 – 0.13 1˚ – 26’0.25 2 – 5/8 x 3 1/4 6.13 9.43 2.13 5.5120127.0 3100 39250 0 – 3.2 21 156 240 54 2.5 5 5.563 450 10.935 0 – 0.13 1˚ – 18’0.27 2 – 5/8 x 3 1/4 6.88 10.07 2.13 5.8125141.3 3100 48660 0 – 3.2 23 175 256 54 2.6 133.0 mm 5.250 450 9.735 0 – 0.13 1˚ – 21’0.28 2 – 16 x 82.5 6.55 9.37 2.13 6.0133.0 3100 43325 0 – 3.2 24 166 238 54 2.7 139.7 mm ‡5.500 450 10.665 0 – 0.13 1˚ – 18’0.28 2 – 5/8 x 3 1/4 6.80 9.59 2.13 6.3139.7 3100 47460 0 – 3.2 24 173 244 54 2.9 152.4 mm 6.000 450 12.735 0 – 0.13 1˚ – 12’0.21 2 – 5/8 x 3 1/4 7.38 10.48 1.88 6.2152.4 3100 56670 0 – 3.2 18 187 266 48 2.8 6 6.625 450 15.525 0 – 0.13 1˚ – 5’0.23 2 – 5/8 x 3 1/4 8.00 11.07 2.13 7.0150168.3 3100 69085 0 – 3.2 18 203 281 54 3.2 Z X Y Continued on page 3. * † @ ‡ Refer to notes on page 3. 06.05_ Flexible Coupling STYLE 75 06.05CARBON STEEL PIPE – GROOVED COUPLINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. . REV_J DIMENSIONS Size Max. Work Pressure *Max. End Load *Allow. Pipe End Sep. †Deflect. Fr. CL†Bolt/Nut@ No – Size Dimensions – Inches/mm Approx. Wgt. Each Nominal Size Inchesmm Actual Outside Diameter Inchesmm psi kPa Lbs.N Inches mm Per Cplg. Deg. Pipe In./Ft.mm/m Inches X Y Z Lbs. kg 159.0 mm 6.250 450 13.800 0 – 0.13 1˚ – 9’0.24 2 – 16 x 82.5 7.63 10.49 2.13 6.8159.0 3100 61405 0 – 3.2 20 194 266 54 3.1 203.2 mm #8.000 450 22.635 0 – 0.13 0˚ – 54’0.16 2 – 3/4 x 4 1/4 9.72 13.33 2.31 12.6203.2 3100 100725 0 – 3.2 13 247 339 58 5.7 8 8.625 450 26.280 0 – 0.13 0˚ – 50’0.18 2 – 3/4 x 4 1/4 10.34 13.97 2.32 12.4200219.1 3100 116945 0 – 3.2 14 263 355 59 5.6 254.0 mm #10.000 350 27.500 0 – 0.13 0˚ – 43’0.15 2 – 7/8 x 5 1/2 12.16 15.81 2.53 20.8254.0 2400 122375 0 – 3.2 11 309 402 64 9.4 304.8 mm #12.000 350 39.500 0 – 0.13 0˚ – 36’0.13 2 – 7/8 x 5 1/2 14.16 17.69 2.53 23.6304.8 2400 175775 0 – 3.2 9 360 449 64 10.7 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. † Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/4 – 3 1/2"/20 – 90 mm; 25% for 4"/100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. Z X Y 06.05_ Flexible Coupling STYLE 75 06.05CARBON STEEL PIPE – GROOVED COUPLINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. . REV_J WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. 06.05 Flexible Coupling STYLE 75 CARBON STEEL PIPE – GROOVED COUPLINGS For complete contact information, visit www.victaulic.com 06.05 470 REV J UPDATED /008 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2008 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 06.05 WCAS-7BDNAR FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD-developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock EZ® Style 009N/Style 009H couplings. Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: • Orange enamel. • Red Enamel in EMEA-I. • Optional: Hot dipped galvanized. MATERIAL SPECIFICATIONS 10.03_1 FireLock® Fittings 10.03IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS JOB/OWNER CONTRACTOR ENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K See Victaulic publication 10.01 for details VNIIPO DIMENSIONS C to E Cto E NO. 001 C to E NO. 003 Cto E CtoE NO. 002 T NO. 006 Size No. 001 90° Elbow No. 003 45° Elbow No. 002 Straight Tee No. 006 Cap Nominal Size Inchesmm Actual Outside Diameter Inchesmm C to E Inchesmm Approx. Weight Each Lbs.kg C to E Inchesmm Approx. Weight Each Lbs.kg C to E Inchesmm Approx. Weight Each Lbs.kg Thickness “T” Inchesmm Approx. Weight Each Lbs.kg 1 1/4 1.660 ——————0.8 0.33242.4 21 0.1 1 1/2 1.900 ——————0.82 0.44048.3 ——————21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.65060.3 70 0.8 51 0.8 70 1.1 22 0.3 2 1/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.06573.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 ————76.1 76 1.5 57 1.1 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.28088.9 86 1.8 64 1.4 86 2.4 22 0.5 108 mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 ——108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4100114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1125141.3 124 5.7 83 3.8 124 7.1 25 1.9 159 mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 ——158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9150168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7200219.1 173 11.6 108 9.3 176 17.6 29 5.8 10.03_2 FireLock® Fittings 10.03IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K FLOW DATA Size Frictional ResistanceEquivalent Feet/meters of Straight Pipe † Nominal Size Inchesmm Actual Outside Diameter Inchesmm Elbows No. 002 Straight Tee No. 001 90° Elbow No. 003 45° Elbow Branch Run 1 1/4 1.660 ————32 42.4 ———— 1 1/2 1.900 ————40 48.3 ———— 2 2.375 3.5 1.8 8.5 3.55060.3 1.1 0.5 2.6 1.1 2 1/2 2.875 4.3 2.2 10.8 4.36573.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.576.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.08088.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8100114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5125141.3 2.6 1.3 6.4 2.6 159 mm 6.250 9.4 4.9 25.0 9.6158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0150168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0200219.1 4.0 1.5 10.1 4.0 † The flow data listed is based upon the pressure drop of Schedule 40 pipe. 10.03_3 FireLock® Fittings 10.03IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the “EZ” marking on the inside face or No. 60 end caps containing the “QV EZ” marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. GENERAL NOTES 10.03 FireLock® Fittings IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS For complete contact information, visit www.victaulic.com 10.03 1539 REV K UPDATED 09/2012 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03 R IPS CARBON STEEL PIPE – FIRE PROTECTION PRODUCTS VICTAULIC ® IS AN ISO 9001 CERTIFIED COMPANY ® REGISTERED TRADEMARK OF VICTAULIC – © COPYRIGHT 2004 VICTAULIC – PRINTED IN U.S.A.1477 REV D 10.04 Victaulic Company of America • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • e-mail:pickvic@victaulic.com Victaulic Company of Canada • Phone: 905-884-7444 • Fax: 905-884-9774 • e-mail: viccanada@victaulic.com Victaulic Europe • Phone:32-9-381-1500 • Fax: 32-9-380-4438 • e-mail: viceuro@victaulic.be Victaulic America Latina • Phone: 610-559-3300 • Fax: 610-559-3608 • e-mail: vical@victaulic.com Victaulic Asia Pacific • Phone: 65-6235-3035 • Fax: 65-6235-0535 • e-mail: vicap@victaulic.com Style 744 FireLock ® Flange Adapter with Vic-Plus™ Gasket System PRODUCT DESCRIPTION Style 744 FireLock Flange adapter is designed for directly incorporating flanged components with ANSI CL. 125 or CL. 150 bolt hole patterns into a grooved pipe system. Sizes 2 - 8" (50 - 200 mm) are hinged for easy handling with integral end tabs which facilitate assembly. The design incorporates small teeth inside the key shoulder I.D. to prevent rotation. Because of the outside flange dimension, FireLock Flange adapters should not be used on FireLock fittings. When wafer or lug-type valves are used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance. FireLock Flange adapters should not be used as anchor points for tie-rods across nonrestrained joints. Mating rubber faced flanges, valves, etc., require the use of a FireLock Flange washer. FireLock Flange adapters with Vic-Plus gaskets do not require lubrication. The gasket must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. Style 744 FireLock Flange Adapters with the Vic-Plus™ Gasket System are designed and recommended for use ONLY on fire protection systems. Vic-Plus Gasket System: Victaulic ® now offers a gasket system which requires no field lubrication on wet pipe systems. The Vic- Plus™ System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (I-100) for supplemental lubrication requirements. DIMENSIONS Exaggerated for Clarity 2 - 8" Sizes (Exaggerated for clarity) ULCUL® FM See Victaulic publication 10.01 for details. Style 744 Sizes 2 - 8" (50 - 200 mm) ANSI Class 125 and 150 Flange Note: Gray area of mating face must be free from gouges, undulations or deformities of any type for effective sealing. B A Z Y WX Pipe Size Max. Work Press.* PSI kPa Max. End Load* Lbs. N No. Bolts † Req’d. Bolt Size † Inches Sealing Surface Inches/mm Dimensions Inches/millimeters Aprx. Wgt. Each Lbs. kg Nominal Diameter In./mm Actual Outside Diameter In./mm “A” Max. “B” Min. W X Y Z 2 2.375 175 775 4 5 / 8 X 2 3 / 4 2.38 3.41 6.75 6.00 4.75 0.75 2.7 50 60,3 1200 3450 60 87 172 152 121 19 1,2 2 1 / 2 2.875 175 1135 4 5 / 8 X 3 2.88 3.91 7.88 7.00 5.50 0.88 4.2 65 73,0 1200 5050 73 99 200 178 140 22 1,9 3 3.500 175 1685 4 5 / 8 X 3 3.50 4.53 8.44 7.50 6.00 0.94 4.8 80 88,9 1200 7500 89 115 214 191 152 24 2,2 4 4.500 175 2780 8 5 / 8 X 3 4.50 5.53 9.94 9.00 7.50 0.94 7.1 100 114,3 1200 11045 114 141 252 229 191 24 3,2 5 5.563 175 4250 8 3 / 4 X 3 1 / 2 5.56 6.71 11.00 10.00 8.50 1.00 8.3 125 141,3 1200 18920 141 171 279 254 216 25 3,8 6# 6.625 175 6030 8 3 / 4 X 3 1 / 2 6.63 7.78 12.00 11.00 9.50 1.00 9.3 150 168,3 1200 26840 168 198 305 279 241 25 4,2 8# 8.625 175 10219 8 3 / 4 X 3 1 / 2 8.63 9.94 14.63 13.50 11.75 1.13 13.9 200 219,1 1200 45475 219 252 372 343 298 29 6,3 *Refer to notes below. †Total bolts required to be supplied by installer. Bolt sizes for conventional flange-to-flange connection. Larger bolts are required when Vic-Flange adapter is utilized with wafer-type valves. # Not available with Vic-Plus gasket system. Lubrication is required. NOTES * Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 ¹⁄₂ times the figures shown. Style 744 FireLock Flange adapters provide rigid joints when used on pipe with standard roll or cut groove dimensions and consequently allow no linear or angular movement at the joint. WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. 2 Style 744 FireLock ® Flange Adapter 10.04 VIC-FLANGE ADAPTER NOTES 1 The Style 744 (2 - 8"/50 - 200 mm) design incorporates small teeth inside the key shoulder I.D. to prevent rotation. 2 FireLock Flange adapter should not be used on FireLock fittings. When wafer or lug-type valves are used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance. 3 FireLock Flange adapters should not be used as anchor points for tie-rods across nonrestrained joints. Mating rubber faced flanges, valves, etc. require the use of a FireLock Flange washer. 4 Area A-B noted in the above drawing must be free from gouges, undulations or deformities of any type for effective sealing. 5 FireLock Flange adapter gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. 6 Flange Washers: FireLock Flange adapters require a smooth hard surface at the mating flange face for effective sealing. Some applications for which the Vic-Flange adapter is otherwise well suited do not provide an adequate mating surface. In such cases, it is recommended that a metal Flange Washer be inserted between the FireLock Flange adapter and the mating flange to provide the necessary sealing surface. Typical applications where a Flange Washer should be used are: A When mating to a serrated flange: a standard flat flange gasket should be used adjacent to the serrated flange and then the Flange Washer is inserted between the FireLock Flange adapter and the flange gasket. B When mating to a wafer valve: where typical valves are rubber lined and partially rubber faced (smooth or not), the Flange Washer is placed between the valve and the FireLock Flange adapter. C When mating a rubber faced flange: the Flange Washer is placed between the FireLock Flange adapters and the rubber faced flange. D When mating AWWA cast flanges to IPS flanges: the Flange Washer is placed between two FireLock Flanges. The hinge points must be oriented approximately 90° to each other. If one flange is not a FireLock Flange adapter (e.g. flanged valve), then a standard flat flange gasket must be placed adjacent to that flange and the Flange Washer inserted between the flange gasket and the FireLock Flange adapter. E When mating to components (valves, strainers, etc.) where the component flange face has an insert: follow the same arrangement as in Application 1. F When mating to a Series 705-W Butterfly valve, Style 744 may only be used on one side of the connection. When ordering Flange Washers, always specify product style (Style 744) and size to assure proper Flange Washer is supplied. MATERIAL SPECIFICATIONS Flange Housing : Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Coating: Black enamel • Optional: Hot dipped galvanized Bolts/Nuts: Supplied by installer Gasket: • Grade “E” EPDM - Type A Vic-Plus Gasket System ∆∆∆∆ (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Ap- proved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated work- ing pressure using the Grade “E” Type A Vic-Plus Gasket System, requiring no field lubrication for most installation conditions. ∆ Standard gasket approved for dry pipe systems to –40°F (–40°C). Based on “typical” pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F (-18°C) and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be rquired on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a “holefinder” locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap II® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade “E” EPDM EPDM (Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade “T” nitrile Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are s ervices for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a l isting of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. 11.02_1 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N PATENTED 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS JOB/OWNER CONTRACTOR ENGINEER System No. __________________________Submitted By ________________________Spec Sect ____________ Para __________ Location ____________________________Date ________________________________Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_M STYLES 920 AND 920N STYLE 920 CROSS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS VNIIPO DIMENSIONS GROOVED OUTLET W ZY V Size Style No.Max. Work Pressure@ Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg 2 × 1/2 (a) ¤ 920N 500 1.50 2.00 2.53 —1.61 5.35 2.75 3.1 —50 15 3450 38.1 51 64 41 136 70 1.5 3/4 (a) ¤ 920N 500 1.50 1.97 2.53 —1.61 5.35 2.75 3.1 —20 3450 38.1 50 64 41 136 70 1.5 1 (a) ¤920N 500 1.50 1.85 2.53 —1.61 5.35 2.75 3.0 —25 3450 38.1 47 64 41 136 70 1.4 1 1/4 (a) †¤920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.232345044.5 52 70 76 41 136 76 1.7 1.5 1 1/2 (a) †¤920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.240345044.5 52 70 79 41 136 83 1.7 1.5 2 1/2 × 1/2 (a) §¤920N 500 1.50 2.21 2.74 —1.82 5.64 2.75 3.0 —65 15 3450 38.1 56 70 46 143 70 1.4 3/4 (a) §¤920N 500 1.50 2.18 2.74 —1.82 5.64 2.75 3.0 —20 3450 38.1 55 70 46 143 70 1.4 1 (a) §¤920N 500 1.50 2.06 2.74 —1.82 5.64 2.75 2.9 —25 3450 38.1 52 70 46 143 70 1.4 1 1/4 † (a) ¤920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.232345044.5 58 76 83 46 160 76 1.7 1.5 1 1/2 † (a) ¤920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.340345050.8 58 76 83 46 159 83 1.7 1.6 76.1 × 1/2 (a)920N 300 1.50 2.22 2.75 —2.25 6.46 3.18 3.9 —15 2065 38.1 56 70 57 164 81 1.8 3/4 (a)920N 300 1.50 2.19 2.75 —2.25 6.46 3.18 3.9 —20 2065 38.1 56 70 57 164 81 1.8 1 (a) 920N 300 1.50 2.07 2.75 —2.25 6.46 3.18 3.8 —25 2065 38.1 53 70 57 164 81 1.7 1 1/4 (a) ¤920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.232345044.5 58 76 84 49 160 76 1.6 1.5 1 1/2 (a) ¤920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.340345050.8 58 76 84 49 160 83 1.6 1.5 3 × 1/2 (a) ¤920N 500 1.50 2.52 3.05 —2.28 6.15 2.75 3.4 —80 15 3450 38.1 64 78 58 156 70 1.6 3/4 (a) ¤920N 500 1.50 2.49 3.05 —2.28 6.15 2.75 3.4 —20 3450 38.1 63 78 58 156 70 1.6 1 (a)920N 500 1.50 2.38 3.06 —2.28 6.15 2.75 3.3 —25 3450 38.1 61 78 58 156 70 1.6 1 1/4 (a) †¤920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.732 (b)3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2 (a) †¤920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.840 (b)3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) ¤920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.650345063.5 70 89 90 58 172 99 2.3 2.1 3 1/2 × 2 920N 500 2.50 3.00 —3.75 2.44 6.72 3.88 —3.89050345063.5 76 95 62 171 99 1.8 TABLE CONTINUED ON PG. 3 FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. 11.02_2 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_M DIMENSIONS GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm Size Style No.Max. Work Pressure@ Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 2 4 × 1/2 (a) ¤920N 500 1.50 3.03 3.56 —2.69 7.01 2.75 3.7 —100 15 3450 38.1 77 90 68 178 70 1.8 3/4 (a) ¤920N 500 1.50 3.00 3.56 —2.69 7.01 2.75 3.7 —20 3450 38.1 76 90 68 178 70 1.8 1 (a) ¤920N 500 1.50 2.88 3.56 —2.69 7.01 2.75 3.6 —25 3450 38.1 73 90 68 178 70 1.8 1 1/4 (a) †¤920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.632 (b)3450 44.5 78 96 102 68 178 76 1.9 1.8 1 1/2 (a) †¤920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.940 (b)3450 50.8 83 102 102 68 178 83 2.0 1.9 2 (a) †¤920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.650345063.5 83 102 102 68 178 99 2.3 2.1 2 1/2 (a) †920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.065345069.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 —4.00 2.69 7.34 4.63 —6.4345069.9 73 102 68 186 118 2.9 3 (a) †920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.480345088.9 84 114 105 68 196 130 3.8 2.9 108.0 × 1 1/4 (a)¤920N 500 1.75 3.08 3.78 —2.63 7.64 3.05 5.0 —32 3450 44.5 78 96 67 194 78 2.3 1 1/2 (a)¤920N 500 2.00 3.28 4.00 —2.63 7.64 3.25 5.0 —40 3450 50.8 83 102 67 194 83 2.3 2 (a)920N 500 2.50 3.25 4.00 —2.63 7.64 4.00 4.0 —50 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8345069.9 73 102 102 67 194 109 3.6 3.5 3 (a)920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.580345088.9 84 114 114 67 194 124 3.1 3.0 5 × 1 1/2 (a) †920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.612540345050.8 102 121 121 80 246 94 3.4 3.4 2 (a) †920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.050345063.5 102 121 121 80 246 111 3.7 3.6 2 1/2 (a) †920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.965345069.9 92 121 121 80 246 118 3.8 3.6 76.1 mm ¤920 500 2.75 3.75 —4.75 3.16 9.70 4.63 —8.0345069.9 95 121 80 246 118 3.6 3 (a) †920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.880345088.9 97 127 118 80 246 135 3.8 4.0 133.0 × 2 920N 500 2.50 3.75 4.50 —3.17 8.00 3.88 8.0 —50 3450 63.5 95 114 81 203 99 3.6 3 920 500 3.50 3.81 5.00 —3.00 9.46 5.31 8.0 —80 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG. 4 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. 11.02_3 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_M DIMENSIONS GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm Size Style No.Max. Work Pressure@ Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 3 139.7 × 1 1/2 †920N 500 2.00 3.78 4.50 —3.30 8.23 3.25 7.0 —40 3450 50.8 96 114 84 209 83 3.2 2 †920N 500 2.50 3.75 4.50 —3.30 8.23 3.88 9.0 —50 3450 63.5 95 114 84 209 99 4.1 6 × 1 1/4 (a)920N 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.815032 (b)3450 44.5 112 130 130 96 232 83 2.3 2.2 1 1/2 (a) †¤920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.140 (b)3450 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) †¤920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.650345063.5 111 130 130 96 232 99 2.7 2.5 2 1/2 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.665345069.9 110 130 130 94 267 118 3.8 3.4 76.1 mm ¤920 500 2.75 4.15 —5.21 3.69 10.51 4.63 —8.4345069.9 105 132 94 267 118 3.8 3 (a) †920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.480345088.9 110 140 130 94 267 135 4.5 3.8 4 (a) †¤920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.11003450114.3 97 146 137 94 267 159 4.6 4.6 159.0 × 1 1/2 (a)920N 500 2.00 4.41 5.13 —3.63 9.40 3.25 7.8 —40 3450 50.8 112 130 92 239 83 3.5 2 (a)920N 500 2.50 4.38 5.13 —3.63 9.40 3.88 8.0 —50 3450 63.5 111 130 92 239 99 3.6 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5345069.9 111 140 130 92 239 118 4.3 4.3 3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.080345088.9 110 140 130 92 239 135 3.7 6.4 108.0 mm 920 500 4.50 4.45 —5.38 3.63 9.40 6.12 —10.03450114.3 113 137 92 239 155 4.5 4 920 500 4.50 3.81 5.75 —3.63 9.40 6.25 18.0 —100 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG. 5 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. 11.02_4 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_M Size Style No.Max. Work Pressure@ Dimensions Approx. Weight Each Run × Branch Nominal Size Inches mm 920 or 920N psi kPa Hole Diameter +0.13 -0.00 T** Inches mm V ‡ # Thd. Inches mm V ‡ Grv. Inches mm W Inches mm Y Inches mm Z Inches mm Female Thd. Lbs. kg Grv. Lbs. kg TABLE CONTINUED FROM PAGE 4 165.1 × 1 920N 500 1.50 3.88 4.56 —3.79 9.34 2.75 8.0 —25 3450 38.1 99 116 96 237 70 3.6 1 1/4 ¤920N 500 1.75 4.43 5.13 —3.79 9.34 3.25 8.4 —32 3450 44.5 113 130 96 237 83 3.8 1 1/2 (a) †¤920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.440345050.8 112 130 130 96 237 83 3.8 2.4 2 (a) †920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.050345063.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6345069.9 110 130 132 92 267 118 3.9 3.4 3 (a) † Ø 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.480345088.9 110 140 130 92 267 135 4.6 3.8 4 (a) †¤920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.41003450114.3 97 146 137 92 267 159 4.8 3.8 8 × 2 (a) †920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.620050345069.9 138 157 159 122 316 114 5.3 5.3 2 1/2 (a) †920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.665345069.9 129 157 157 122 316 114 5.3 5.3 76.1 mm ¤920 500 2.75 5.25 —6.25 4.81 12.42 4.56 —11.6345069.9 133 159 122 316 116 5.3 3 (a) †¤920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.680345088.9 135 165 165 122 316 135 5.7 5.3 4 (a) †¤920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.51003450114.3 122 171 162 122 316 159 6.9 5.7 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). † Available with grooved or female threaded outlet. Specify choice on order. ‡ Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.` (a) British Standard female pipe threaded outlet is available as listed. Specify “BSPT” clearly on order. (b) For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services ¤ LPCB approved for fire protection services Ø Approved for use in China by Tianjin Approvals Company. DIMENSIONS GROOVED OUTLET W ZY V FEMALE THREADED OUTLET T W ZY V Important notes: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 × ½"/50 × 15 mm through 8 × 4"/200 × 100 mm 11.02_5 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_M FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. CV and Kv Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for CV /Kv Values: 1 2 Exaggerated for clarity OUTLET SIZE Equivalent Length ofOutlet Size Schedule40 Carbon Steel Pipe(per UL 213, Sec. 16) (C = 120)ŧ FT CV/KV Values NOMINALDIAMETER In/mm ACTUALO.D. In/mm GROOVED THREADED GROOVED THREADED 1/2 0.840 -2 -11 15 21.3 9.4 3/4 1.050 -4 -16 20 26.7 13.7 1 1.315 -8 -21 25 33.7 1.8 1 1/4 1.660 5 1/2 6 50 48 32 42.7 42.9 41.1 1 1/2 1.900 11 11 53 53 40 98.3 45.4 45.4 2 2.375 9 10 1/2 112 104 50 60.3 96 89.1 2 1/2 2.875 20 12 1/2 119 150 65 73.0 102 128.5 3.000 16*-161 -76.1 mm 76.1 138.1 3 3.500 14 15 1/2 249 237 80 88.9 213.4 203.1 4 4.500 20 22 421 401 100 114.3 360.8 343.6 ŧ Hazen-Williams coefficient of friction is 120.* Pipe with a wall thickness of 0.165in./4.2mm. 11.02_6 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_M FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size Pipe Approval Agency Rated Working Pressures – psi/kPa Nominal Size Inches/mm Actual Outside Diameter Inches/mm Inches/mm Schedule UL ULC FM LPCB Vds (Style 920)(Style 920N) 21/2 - 6 2.875 - 6.625 All 10, 40 400 400 400 290 232 36265 - 150 73.0 - 168.3 2755 2755 2755 1999 1599 2496 21/2 - 4 2.875 - 4.500 All DF 300 300 300 290 232 36265 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 21/2 - 4 2.875 - 4.500 All SF 300 300 300 290 232 36265 - 100 73.0 - 114.3 2065 2065 2065 1999 1599 2496 6 6.625 3, 4 10 300 300 250 290 232 362150168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30, 40 300 300 300 290 232 362150168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10, 40 400 ———145 —200 219.1 2755 1000 8 8.625 3,4 10 300 —250 —145 —200 219.1 2065 1724 1000 8 8.625 3,4 30, 40 300 —300 —145 —200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 8"/100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100 mm, 5"/125 mm, 6"/150 mm and 8"/200 mm diameter pipe. The Style 931 comes with a 2 ½"/65 mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. 11.02_7 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_M WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. 11.02_L Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11.02CARBON STEEL PIPE - HOLE CUT PRODUCTS For complete contact information, visit www.victaulic.com 11.02 1480 REV M UPDATED 03/2012 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. Project InformatIon:aPProval StamP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Rev. 06.09.06-00 ® For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF O'Lets MT-40 Weld Outlets The SPF™ Model MT-40 Weld Outlet Fitting provides an economical threaded outlet branch connection. Fittings are forged steel per ASTM A-05 and are available in outlet sizes of ⁄2" through 2" for ⁄4" through 8" run pipe sizes. A precise fit at the opening in the run pipe is achieved through the MT-40’s contoured shape and conforms to standard practice MSS SP- 97. The weld bevel is a standard 37⁄2°. The MT-40 may be installed on all schedules of steel pipe. each outlet size requires only one hole size across the run pipe range, minimizing hole saw/drills needed for component installation. MT-40 threads comply with ANSI/ASMe B.20. for NPT. All fittings are UL/ULC Listed and all fittings except ⁄4 x ⁄4, ⁄2 x ⁄2, and 2 x 2 are FM Approved for use in fire protection systems at 75 PSI for schedule 5 pipe and 300 PSI for schedule 7 pipe and above. For the latest UL/ULC Listed and FM Approved pressure ratings versus pipe schedule see www.anvilstar.com or contact your local AnvilStar Sales Representative. PAge  OF 3 For Listing/Approval Detailsand Limitations visit our Web Site www.anvilintl.com or contact an Anvil®/AnvilStar™ Sales Representative. Rev. 06.09.06-002 ® For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF O'Lets MT-40 Weld Outlets B A CFigure MT-40 Weld OuTleTs Outlet Size Nominal Size Outlet HeightA Inside Diameter B Recommended Hole Size Take Out C Approx. Wt. Ea. In./mm In./DN(mm)In./mm In./mm In./mm In./mm Lb./kg 1⁄2 x 13 x 11⁄4 - 11⁄2 11⁄16 11⁄16 5⁄8 9⁄16 0.171 32 - 40 27.0 17.5 15.9 14.3 0.08 11⁄2 - 2 11⁄16 11⁄16 5⁄8 9⁄16 0.171 40 - 50 27.0 17.5 15.9 14.3 0.08 2 - 21⁄2 11⁄16 11⁄16 5⁄8 9⁄16 0.171 50 - 65 27.0 17.5 15.9 14.3 0.08 21⁄2 - 8 11⁄16 11⁄16 5⁄8 9⁄16 0.169 65 - 200 27.0 17.5 15.9 14.3 0.08 3⁄4 x 19 x 11⁄4 - 11⁄2 11⁄8 7⁄8 7⁄8 9⁄16 0.260 32 - 40 28.6 22.2 22.2 14.3 0.12 11⁄2 - 2 11⁄8 7⁄8 7⁄8 9⁄16 0.260 40 - 50 28.6 22.2 22.2 14.3 0.12 2 - 21⁄2 11⁄8 7⁄8 7⁄8 9⁄16 0.260 50 - 65 28.6 22.2 22.2 14.3 0.12 21⁄2 - 8 11⁄8 7⁄8 7⁄8 9⁄16 0.256 65 - 200 28.6 22.2 22.2 14.3 0.12 1 x 25 x 11⁄4 - 11⁄2 11⁄4 13⁄16 11⁄8 5⁄8 0.331 32 - 40 31.8 30.2 28.6 15.9 0.15 11⁄2 - 2 11⁄4 13⁄16 11⁄8 5⁄8 0.331 40 - 50 31.8 30.2 28.6 15.9 0.15 2 - 21⁄2 11⁄4 13⁄16 11⁄8 5⁄8 0.320 50 - 65 31.8 30.2 28.6 15.9 0.15 21⁄2 - 3 11⁄4 13⁄16 11⁄8 5⁄8 0.314 65 - 80 31.8 30.2 28.6 15.9 0.14 3 - 4 11⁄4 13⁄16 11⁄8 5⁄8 0.309 80 - 100 31.8 30.2 28.6 15.9 0.14 5 - 8 11⁄4 13⁄16 11⁄8 5⁄8 0.291 125 - 200 31.8 30.2 28.6 15.9 0.13 11⁄4 x 32 x 11⁄4 - 11⁄2 13⁄8 11⁄2 11⁄2 11⁄16 0.432 32 - 40 34.9 38.1 38.1 17.5 .019 11⁄2 - 2 13⁄8 11⁄2 11⁄2 11⁄16 0.421 40 - 50 34.9 38.1 38.1 17.5 .019 2 - 21⁄2 13⁄8 11⁄2 11⁄2 11⁄16 0.421 50 - 65 34.9 38.1 38.1 17.5 .019 21⁄2 - 3 13⁄8 11⁄2 11⁄2 11⁄16 0.411 65 - 80 34.9 38.1 38.1 17.5 .019 3 - 4 13⁄8 11⁄2 11⁄2 11⁄16 0.389 80 - 100 34.9 38.1 38.1 17.5 .018 5 - 8 13⁄8 11⁄2 11⁄2 11⁄16 0.389 125 - 200 34.9 38.1 38.1 17.5 .018 Figure MT-40 Weld OuTleTs Outlet Size Nominal Size Outlet HeightA Inside Diameter B Recommended Hole Size Take Out C Approx. Wt. Ea. In./mm In./DN(mm)In./mm In./mm In./mm In./mm Lb./kg 11⁄2 x 40 x 11⁄2 15⁄8 15⁄8 15⁄8 15⁄16 0.477 40 41.3 41.3 41.3 23.8 .022 2 15⁄8 15⁄8 15⁄8 15⁄16 0.477 50 41.3 41.3 41.3 23.8 .022 21⁄2 15⁄8 15⁄8 15⁄8 15⁄16 0.477 65 41.3 41.3 41.3 23.8 .022 3 - 4 15⁄8 15⁄8 15⁄8 15⁄16 0.477 80 - 100 41.3 41.3 41.3 23.8 .022 4 15⁄8 15⁄8 15⁄8 15⁄16 0.477 100 41.3 41.3 41.3 23.8 .022 5 - 8 15⁄8 15⁄8 15⁄8 15⁄16 0.477 125 - 200 41.3 41.3 41.3 23.8 .022 2 x 50 x 2 13⁄4 21⁄16 2 11⁄16 0.857 50 44.5 52.4 50.8 27.0 0.38 21⁄2 13⁄4 21⁄16 2 11⁄16 0.829 65 44.5 52.4 50.8 27.0 0.38 3 13⁄4 21⁄16 2 11⁄16 0.829 80 44.5 52.4 50.8 27.0 0.39 4 13⁄4 21⁄16 2 11⁄16 0.800 100 44.5 52.4 50.8 27.0 0.36 5 13⁄4 21⁄16 2 11⁄16 0.743 125 44.5 52.4 50.8 27.0 0.34 6 13⁄4 21⁄16 2 11⁄16 0.743 150 44.5 52.4 50.8 27.0 0.34 8 13⁄4 21⁄16 2 11⁄16 0.743 200 44.5 52.4 50.8 27.0 0.34 PAge 2 OF 3 Rev. 06.09.06-003 ® For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Submittal Sheet SPF O'Lets MT-40 Weld Outlets Installation -Model MT-40 Weld Outlet Thread Assembly Instructions •SPFTM Outlet Fittings are designed to be installed using only one weld pass. •1/2"size outlets have a heavy cross section which helps to prevent weld/heat induced distortion during installation. •3/4"-2"size outlets maintain a relative uniform wall thickness in the contoured section.Heat settings can easily be set to allow for full penetration welds while reducing the probability of burn through.The weld area is designed adequately distanced from the threads such that the welding process should not distort the threads. •It is recommended that the weld temperature be only as hot as needed to fully penetrate the materials beingwelded.Excessive heat may cause the outlet fitting to expand excessively resulting in threads not gauging properly after cooling.The following chart lists the recommended amount of weld for each size outlet. THREAD INSPECTIONA.Prior to installing a threaded branch pipe or nipple into a MT-40 outlet fitting,inspect the thread of the outlet and the nipple to insure that: 1)No dirt or weld spatter is in the threads. 2)No burn –through has damaged the threads.3)Thread length is correct. B.Clean as needed. APPLICA TION OF PIPE SEALANT A.Use a pipe sealant that is fast drying,sets-upsemi-hard and is vibration resistant. For outlets 1/2"through 1",an anaerobic pipe sealant is recommended. B.Thread tape containing Teflon*may also be used. TIGHTENING OF BRANCH PIPE A.For outlet sizes through 2",wrench tighten up to three (3)full turns past handtight. *Teflonis a registered trademark of DuPont. Outlet A B Size (Inches)(Inches) 1/2 1/4 3/16 3/4 1/4 3/16 1 1/4 3/16 11/4 1/4 3/16 11/2 5/16 1/4 2 5/16 1/4 PAge 3 OF 3 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com78 Ductile Iron Threaded Fittings SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com79 Ductile Iron Threaded Fittings TemperatureDegrees F Working Pressure, Nonshock PsIG300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Specifications • The branded Ductile Iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • Ductile Iron castings conform to ASTM A536 • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • Fittings are 100% air tested • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical & physical properties • Manufacturing facilities are ISO 9001:2000 and ISO 14001 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com D U C T I l e A A A A A A AA B size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 size IN Part Number a IN B IN Packing Weight LBInnerMaster 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 Fig. 35E 3 – 90° Elbow Fig. 35RE3 – 90° Reducing Elbow Fig. 35F 3 – 45° Elbow Fig. 35T 3 – Tee Ductile Iron Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com D U C T I l e A B AB C C size IN Part Number a IN B IN C IN Packing Weight LBInnerMaster 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 size IN Part Number a IN B IN C IN Packing Weight LBInnerMaster 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 Fig. 35BT3 – Bull Head Tee Fig. 35RT3 – Reducing Tee Ductile Iron Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com D U C T I l e A A A AA B size IN Part Number a IN Packing Weight LBInnerMaster 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 size IN Part Number a IN Packing Weight LBInnerMaster 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex)35RC3020010 2.81 20 40 1.0 size IN Part Number a IN Packing Weight LBInnerMaster 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35CP3 – Straight Coupling with Ribs Fig. 35RC3 – Hex Reducing Coupling Fig. 35HB3 – Hex Bushing Fig. 35SP3 – Square Head Plug Fig. 35U 3 – Union with Brass Seat Ductile Iron Fittings - Class 300 UL/FM SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com D U C T I l e A A A A A A A B B size IN Part Number a IN B IN Packing Weight LBInnerMaster 1-1/4 x 1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 size IN Part Number a IN Packing Weight LBInnerMaster 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 size IN Part Number a IN Packing Weight LBInnerMaster 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35X 3 – Cross Fig. 35RX3 – Reducing Cross Fig. 35C 3 – Cap Ductile Iron Fittings - Class 300 UL/FM size IN Part Number a IN Packing Weight LBInnerMaster 3/8 35BC3003 0.75 100 200 0.3 1/2 35BC3004 0.75 80 160 0.5 Fig. 35BC3 – Beam Clamp A SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com84SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 84 SMITH-COOPER INTERNATIONAL (SCI) warrants to its initial purchaser only, that its products which are delivered to this initial purchaser will be of the kind described in the order or price list and will be free of defects in workmanship or material for a period of five years from the date of delivery to our initial purchaser. Should any failure to conform to this warranty appear within five years after the date of the initial delivery to our initial purchaser, SCI will, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accor- dance with recognized engineering and piping practices and industry standards, correct such defects by suitable repair or replacement (which alternative shall be at the discretion of SCI) of product at SCI’s own expense upon return of the defective part to SCI. In the event that SCI elects to replace the defective product, SCI shall pay up to $50 per defective product for total cost of replacement. In the event of multiple claims, such payment shall be no greater than $1,000 for each installation project. This warranty applies only during normal use that meets the above referenced conditions of installation and operation and is absolutely void if the product has been damaged after purchase or if it has been misused, repaired, altered or modified in any manner whatsoever. SCI shall not warranty any of its products if any portion of the product including without limitation, any component, gasket, housing or bolt has been modified, altered, remanufactured or replaced in any manner by any customer, user of the product or third party. Correction of non-conformities, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of SCI to our initial purchaser, with respect to the goods, whether based on contract, negligence, strict tort, or otherwise. It is the intention of SCI that no warranty of any kind, whether expressed or implied shall pass through our initial purchaser to any other person or corpora- tion. No returns will be allowed unless prior written permission of SCI is first obtained. Buyers shall be responsible for all costs of transporta- tion as well as a restocking charge. This warranty is exclusively for the benefit of the initial purchaser of this product from SCI and, except to the extent prohibited by ap- plicable law, the foregoing warranty is in lieu of all other warranties, express or implied, including but not limited to warranties of fitness or merchantability. LIMITATIONS OF LIABILITY: SCI shall not under any circumstances be liable for special or consequential damages such as, but not limited to damage to loss of other property or equipment, loss of profits or revenue, cost of capital, cost of purchased or replacement goods, claims of customers of our initial purchaser, any labor cost for repair or replacement of the product or damage caused by the product. The remedies of our initial purchaser, and all others, set forth herein are exclusive, and the liability of SCI with respect to same shall not, except as expressly provided herein, exceed the price of the SCI products on which such liability is based. Warranty and Limitations of Liability © 2010 Smith-Cooper International® SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com85 Toll Free 800-766-0076 Fax 323-890-4456 www.smithcooper.com Industrial PVF Malleable Iron Cast Iron Ductile Iron Bronze Fittings Flanged Fittings Forged Steel Fittings Merchant Steel COOPLETS® Nipples Lead Free Valves Ball Gate Globe Check Butterfly Straight Stops Hose Bibbs / Sillcocks Boiler Drains Specialties Stainless Steel 150# Fittings 3000# Forged Fittings Weld Fittings Sanitary Fittings Compression Fittings Flanges Nipples Pipe & Tubing Valves Grooved Couplings Fittings Valves COOPLET® Adapter Nipples Los Angeles, CA · Atlanta, GA · Vancouver, WA · Chicago, IL 0710