HomeMy WebLinkAboutVVMC Valves Hose FireStop.pdfNIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 40 AHEAD OF THE FLOW® www.nibco.com MATERIAL LIST PART SPECIFICATION 1. Upper Stem Stainless Steel ASTM A 582 Type 416 2. Upper Bushing PTFE Bronze Sintered on Steel 3. "O" Ring Buna-N 4. Body Ductile Iron ASTM A 395 with Polymide Coating 5. Disc Ductile Iron ASTM A 395 with EPDM Encapsulation 6. Lower Bushing PTFE Bronze Sintered on Steel 7. Lower Stem Stainless Steel ASTM A 582 Type 416 8. Dust Plug PVC 9. Nameplate Aluminum 10. Gear Operator Cast Iron and Steel 11. Indicator Flag Cast Iron 12. Handwheel Cast Iron *-8N version has two factory mounted internal supervisory switches. -4N version is gear operated only Uses NIBCO model #TS-4 Switch Kit. Polymide coating has NSF certification. Dimensions Size J K L M N P Q R Weight In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. Lbs. Kg. 2¹⁄₂ 65 3.54 90 2.13 54 5.82 148 5.67 144 4.19 106 3.25 83 5.9 150 3.46 88 22 10.0 3 O.D. 76 3.54 90 2.13 54 5.82 148 5.67 144 4.19 106 3.25 83 5.9 150 3.46 88 22 10.4 3 80 3.54 90 2.13 54 5.82 148 5.94 151 4.44 113 3.54 90 5.9 150 3.97 101 23 10.4 4 100 3.54 90 2.13 54 7.64 194 6.31 173 5.33 135 4.35 110 5.9 150 5.03 128 28 12.7 5 125 3.54 90 2.13 54 7.64 194 7.32 186 5.83 148 4.84 123 5.9 150 6.27 159 31 14.1 6 150 3.54 90 2.13 54 7.64 194 8.62 219 7.11 181 5.93 151 5.9 150 7.25 184 41 18.6 6 O.D. 165 3.54 90 2.13 54 7.64 194 8.62 219 7.11 181 5.93 151 5.9 150 7.25 184 41 18.6 8 200 3.54 90 2.13 54 7.91 201 9.80 249 8.05 204 6.87 174 9.8 250 9.25 235 53 24.1 10 250 3.98 101 3.03 77 9.49 241 11.61 295 9.86 250 9.17 233 11.8 300 11.25 286 88 40.0 300 PSI/20.7 Bar Non-Shock Cold Water 2¹⁄₂" - 8" 175 PSI/12.1 Bar Non-Shock Cold Water 10" UL/ULC LISTED • FM APPROVED • 2¹⁄₂" - 10" UL LISTED FOR INDOOR AND OUTDOOR SERVICE • CALIFORNIA STATE FIRE MARSHALL APPROVAL NO. 7770-1243:101 • APPROVED BY THE NEW YORK CITY MEA 9-97-E WITH APPROPRIATE NYC INDICATOR 300 lb. WWP UL/FM Butterfly Valves Fire Protection Valve • Grooved Mechanical Style • Nylon Coated Ductile Iron • Extended Neck • Elastomer Encapsulated Disc • Accepts Internal Supervisory Switches DIMENSIONS—WEIGHTS—QUANTITIES Dimensions Size A B C D E F G H In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. 2¹⁄₂ 65 2.88 73 2.72 69 0.31 8 0.63 16 3.85 98 2.42 61 11.94 303 2.91 74 3 O.D. 76 3.00 76 2.84 72 0.31 8 0.63 16 3.85 98 2.42 61 11.94 303 2.91 74 3 80 3.50 89 3.34 85 0.31 8 0.63 16 3.85 98 2.86 73 12.48 317 2.91 74 4 100 4.50 114 4.33 110 0.38 10 0.63 16 4.56 116 3.84 98 14.18 360 2.91 74 5 125 5.56 141 5.39 137 0.38 10 0.63 16 5.86 149 4.79 122 15.17 385 2.91 74 6 150 6.63 168 6.45 164 0.38 10 0.63 16 5.86 149 5.73 146 17.54 446 2.91 74 6 O.D. 165 6.51 165 6.32 161 0.38 10 0.63 16 5.86 149 5.73 146 17.54 446 2.91 74 8 200 8.63 219 8.44 214 0.44 11 0.75 19 5.26 134 7.71 196 19.42 493 2.91 74 10 250 10.75 273 10.56 268 0.50 13 0.75 19 6.29 160 9.56 243 24.03 610 3.90 99 GD-4765-8N* Grooved 2¹⁄₂" thru 8" GD-1765-8N 10" (not shown) Revised 5/2/2007 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 41 AHEAD OF THE FLOW® www.nibco.com Revision 8/30/2010 D E A G M F C Butterfly Post Assembly DIMeNSIONS—WeIGHTS—QUANTITIeS Valve A C D e F G M Size Grooved Wafer/ Grooved Wafer/ Grooved Wafer/ Lug Lug Lug Grooved Wafer Lug 2 ---- 2.50 6 ---- 5.38 ----- 2.88 8 5.31 ---- 50 51 2¹⁄₂ 2.50 2.88 6 4.21 5.88 3.24 3.25 8 5.31 51 52 53 3 2.93 3.13 6 4.42 6.13 3.53 3.38 8 5.31 53 53 54 4 3.93 4.13 6 5.30 6.88 4.34 4.00 8 5.31 56 56 59 5 ---- 5.13 6 ---- 7.38 ---- 4.75 8 5.31 ---- 59 63 6 5.89 6.13 6 7.07 8.00 5.92 5.25 8 5.31 ---- 62 68 8 7.87 8.13 9 8.00 9.25 7.86 6.50 8 5.31 76 74 80 10 ---- 10.13 18 ---- 10.50 ---- 8.00 7.5 7.25 ---- 91 104 12 ---- 12.13 18 ---- 12.00 ---- 9.25 7.5 7.25 ---- 108 128 D E A G M F C LD-3510-4GP Lug/Wafer Butterfly Underground Post Assembly ** (66" standard length) Butterfly Valves Indicator Post Assemblies Available as Wall Post (WP*) or Underground (GP**) Available with Internal Supervisory Switch 2" - 8" (UL Listed Indoor/Outdoor) - (8N Version) Available with Grooved, Wafer or Lug Style Valves (UL Listed, Not FM Approved) GD-4765-8WP Grooved Butterfly Wall Post Assembly (22" standard length) A S R E Q U I R E D * 9" x 9" painted steel wall plate included with wall post assembly . ** Ground line to top of indicator should be at least 36" . Approx . Net Wt . 22" WP Incl . Wall Plate Mounting Hole Size 2" - 8" — 51/2" hole diameter 10" - 12" — 71/2" hole diameter ES-F-825YD SPECIFICATION SHEET FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise mea-surements, please contact FEBCO. FEBCO reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subse-quently sold. Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location ––––––––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Engineer –––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––– Approval –––––––––––––––––––––––––––––––––––––––––––– Representative –––––––––––––––––––––––––––––––––––––––– Series 825YD Reduced Pressure Zone Assemblies Size: 21⁄2" - 10" (65mm - 250mm) The FEBCO Series 825YD Reduced Pressure Zone Assemblies are used to protect against high hazard (toxic) fluids in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. They are also used in irrigation systems, boilerfeed, water lines and other installations requiring maximum protection. Features • The DuraCheck features all stainless steel check assemblies for corrosion resistance, reduced fouling and longer valve life. • DuraCast ductile iron body for superior strength, corrosion resistance and lighter weight. • Ultimate mechanical protection of potable water against hazards of cross-connection contamination. • Meets all specifications of AWWA, ASSE, the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California, and UL classified for fire sprinkler service. • Documented flow curves established by University of Southern California Foundation for Cross-connection Control and Hydraulic Research. • All bronze modular relief valve for ease of maintenance. • End Detail – 21⁄2" - 10" (65 - 250mm) Flanged ANSI B16.1 Specifications Reduced pressure backflow preventer assemblies shall consist of two independent "Y" configured check valves and one differential relief valve. By design, the assembly shall automatically reduce the pressure in the zone between the check valves. Should the differential between the zone and upstream pressure drop to 2psi, the differential relief valve will open, maintaining proper zone differential. Valve bodies and cover shall be manufactured of ductile iron ASTM A536, Grade 65-45 12, Ductile iron bodies shall be flanged, ANSI B16.1, Class 125, epoxy coated. The assembly shall be constructed so all internal parts, including seat rings, can be serviced from the top or side or removed while assembly is in line. The assembly shall be rated 175psi (12.1 bar) MWWP. Relief valve assembly shall be of a modular design for ease of mainte-nance. The assembly shall meet or exceed requirements of ASSE standard 1013, AWWA standard C511, and the USC Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Reduced pressure backflow preventer assemblies shall be FEBCO 825YD, or prior approved equal. Operation In a flow condition, the check valves are open with the pressure between the checks, called the zone, being maintained at least 5.0psi (34.5 kPa) lower than the inlet pressure and the relief valve is maintained closed. Should abnormal conditions arise under no flow or reversal of flow, the differential relief valve will open and discharge to maintain the zone at least 2psi lower than the supply. In resumption of normal flow, the zone’s differ- ential pressure will resume and the relief valve will close. Pressure – Temperature Maximum Working Pressure: 175psi (12.1 bar) Hydrostatic Test Press: 350psi (24.1 bar) Temperature Range: 32ºF to 140ºF (0ºC to 60ºC) Materials Main Valve Body: Ductile iron grade 65-45-12 fusion epoxy coated internal and external Main Valve Trim: Bronze Internal Check Assembly: Stainless Steel Relief Valve Body and Trim: Bronze Elastomers: Nitrile Diaphragms: Nitrile, fabric reinforced Springs: Stainless Steel Internal Check Assembly: Stainless Steel Shutoffs: Non-rising stem, resilient seated gates Models • OS&Y Gate Valves • Left Handed Relief Valve • NRS Gate Valves • Less Gates 825YD Dimensions – Weights Size: 21⁄2" - 10" (65 - 250mm) size (DN)DimeNsioNs Weight A B C*D E in.mm in.mm in.mm in.mm in.mm in.mm lbs.kgs. 21⁄2 65 373/16 945 221/16 560 125⁄8 321 71⁄2 191 11 279 178 80.7 3 80 4111⁄16 1059 259⁄16 649 127⁄8 327 81⁄16 205 12 305 213 96.6 4 100 507⁄16 1281 325⁄16 821 143⁄8 365 11 279 13 330 360 163.3 6 150 5911⁄16 1516 389⁄16 980 187⁄8 479 14 356 15 381 601 272.6 8 200 693⁄16 1757 461⁄16 1170 231⁄2 597 18 457 16 406 892 404.6 10 250 843⁄16 2138 581⁄16 1475 271⁄2 699 22 559 17 432 1593 722.6 * Applies to NRS gated units only. Dimensions shown are nominal, allowance must be made for normal manufacturing tolerances.A B C e D 30" max (750mm) 12" min (300mm) suggested side View Water meter Protective enclosure support (3" and larger) Approvals • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California.* • ANSI/AWWA Conformance (C511-89) • ULC Listed (21⁄2", 3", 6"-10") * Valves must be supplied with resilient seated shutoff valves for USC approvals to be in effect. Standard Meter is GPM. UL and FM Listings only applicable with approved OS&Y gates. Typical Installation Reduced Pressure Backflow Preventers should be installed with a suggested minimum clearance of 12" (300mm) between port and floor or grade. They must be installed where any discharge will not be objectionable and can be positively drained away. They should be installed where easily accessible for testing and maintenance and must be protected from freezing. Larger sizes should have support blocks to prevent flange damage. Thermal water expansion and/or water hammer down stream of the Backflow Preventer can cause excessive pressure. Excessive pressure situations should be eliminated to avoid possible damage to the system and assembly. The gap drain is not designed to catch the maximum discharge possible from the relief valve. The installation of FEBCO air gap with the drain line terminating above a floor drain will handle any normal discharge or nuisance spitting through the relief valve. However, floor drain size may need to be designed to prevent water damage caused by a catastrophic failure condition. Do not reduce the size of the drain line from the air gap fitting. Capacity 21⁄2" (65mm) kPa psi 138 20 103 15 69 10 34 5 0 50 100 150 200 250 300 gpm 0 190 379 570 760 950 1140 lpm 5 7.5 10 15 20 fps 1.5 2.3 3.1 4.6 6.1 mpsheADloss3" (80mm) kPa psi 138 20 103 15 69 10 34 5 0 50 100 150 200 250 300 gpm 0 190 379 570 760 950 1140 lpm 5 7.5 10 fps 1.5 2.3 3.1 mpsheADloss 4" (100mm) kPa psi 138 20 103 15 69 10 34 5 0 100 200 300 400 500 600 gpm 0 379 760 1140 1520 1900 2280 lpm 5 7.5 10 fps 1.5 2.3 3.1 mpsheADloss 6" (150mm) kPa psi 138 20 103 15 69 10 34 5 0 200 400 600 800 1000 1200 gpm 0 760 1520 2280 3040 3800 4540 lpm 5 7.5 10 fps 1.5 2.3 3.1 mpsheADloss 8" (200mm) kPa psi 138 20 103 15 69 10 34 5 0 400 800 1200 1600 gpm 0 1520 3040 4540 6060 lpm 5 7.5 10 fps 1.5 2.3 3.1 mpsheADloss 10" (250mm) kPa psi 138 20 103 15 69 10 34 5 0 400 800 1200 1600 2000 2400 gpm 0 1520 3040 4540 6060 7600 9090 lpm 5 7.5 fps 1.5 2.3 mpsheADloss1013B64.4 ** A Watts Water Technologies Company USA: Tel: (559) 441-5300 • Fax: (559) 441-5301 • www.FEBCOonline.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.FEBCOonline.ca ES-F-825YD 1330 © 2013 FEBCO NOTICE Model 1011A TESTa n DRaIn® ¾" 1" 1¼" 1½" 2" Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve Reliability, Versatility, Code Compatibility • The AGF Manufacturing Inc. Model 1011A TESTa n DRaIn® matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system, with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. • The Model 1011A complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). • The Model 1011A TESTa n DRaIn® is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. • Available in a full range of sizes from ¾" to 2" NPT and BSPT, with all specifiable orifice sizes ³⁄8" (2.8K), 7⁄16" (4.2K), ½" (5.6K), 17⁄32" (8.0K), 5⁄8" (11.2K, ELO), ¾" (14.0K, ESFR), and K25 as required by NFPA 13, 2007 Edi- tion (see reverse). • The included UL/FM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. • Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-piping outlet. • Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. • A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. • Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1) stem packing, and (1) stem washer are avail- able for all TESTa n DRaIn® valves. Valve and orifice size must be specified when ordering. Note: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to oPeN in a range of pressure between 90% and 105% of their rating. the valves are required to CLoSe at a pressure above 80% of that rating. the relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNot be isolated from the system when the system is operational. A relief valve should NeVeR have a shutoff valve or a plug downstream of its outlet. CS1011A 10/09TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. Model 1011A TESTa n DRaIn® Di m e n s i o n s Orifice Size Available: 3⁄8", 7⁄16", 1⁄2", 17⁄32", ELO (5⁄8")*, ESFR (3⁄4")*, & K25** SIZE A B C D E F G H ¾"79⁄16"(191 mm)11⁄2"(37.5 mm)23⁄16"(57 mm)35⁄8"(93 mm)33⁄8"(86 mm)113⁄16"(46 mm)49⁄16"(117 mm)63⁄8"(162.5 mm) 1"79⁄16" (191 mm) 11⁄2" (37.5 mm) 23⁄16" (57 mm) 35⁄8" (93 mm) 33⁄8" (86 mm) 113⁄16" (46 mm) 49⁄16" (117 mm) 63⁄8" (162.5 mm) 11⁄4"715⁄16" (201 mm) 111⁄16" (43 mm) 29⁄16" (65 mm) 41⁄4" (108 mm) 35⁄8" (91 mm) 115⁄16" (51 mm) 59⁄16" (141 mm) 51⁄2" (192 mm) 1½"815⁄16" (227 mm) 113⁄16" (45 mm) 31⁄4" (81.5 mm) 51⁄16" (127 mm) 37⁄8" (99 mm) 25⁄8" (67 mm) 81⁄4" (207 mm) 107⁄8" (274 mm) 2"815⁄16" (227 mm) 113⁄16" (45 mm) 31⁄4" (81.5 mm) 51⁄16" (127 mm) 37⁄8" (99 mm) 25⁄8" (67 mm) 81⁄4" (207 mm) 107⁄8" (274 mm) * Available on 11⁄4" to 2" size units only ** Available on 11⁄2" and 2" size units only TO DRAIN TO DRAIN H F G E A A INLET D B C Ap p r o v A l s UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM Job Name:__________________________________ Architect: ___________________________________ Engineer: ___________________________________ Contractor: _________________________________ USA Patent # 4741361 and Other Patents Pending mA t e r i A l s Handle: Steel Stem: Rod Brass Ball: C.P. Brass Body: Bronze Valve Seat: Impregnated Teflon® Indicator Plate: Steel Relief Valve: Bronze Bypass Fittings: Brass Bypass Tubing: Nylobraid mo D e l 1011A - Fr o n t vi e w mo D e l 1011A - pl A n vi e w AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Model 1011A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve Factory Rated at 175 PSI with other settings available th e mo D e l 1011A p r o v i D e s A l l o F t h e F o l l o w i n g … From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) – shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow… using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler… Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location… downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler… Chapter 8.17.4.3.2 The trip test connection… with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than ½" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve & 8.16.2.4.3 DETAIL AND SUBMITTAL SHEETGUARDIAN FIRE EQUIPMENT, INC.MIAMI, FL Ph. 800.327.6584 • Fax 800.827.3869 Project/Location: 5000 Series - Hose Valves Architect/Engineer: Date: Contractor: Qty: Appropriate Selection Caps with Chains - Caps with Chains - Used to protect hose thread outlets on valves and hydrants. Cast brass caps (pin lugs)* or red plastic caps (rocker lugs). D C B A B D A C Female x Female Angle Valves - Used with hose rack assemblies. Female NPT inlet and outlet, 300 PSI, cast brass Model No. Size A B (Open)C D Swing Radius 5020 1 1⁄2” x 11⁄2”4” 7 3⁄4”21⁄4”2” 2 1⁄2” 5025 2 1⁄2” x 21⁄2”51⁄4” 11” 3 1⁄4”23⁄4”31⁄2”   Optional Finish: -B Polished Brass -C Rough Chrome Plated -D Polished Chrome Plated B D A C B D A C Model No. Size A B (Open)C D Swing Radius 5040 1 1⁄2” x 11⁄2”4” 8” 2 1⁄2”2” 2 1⁄2” 5045 2 1⁄2” x 21⁄2”51⁄2”111⁄2”31⁄2”21⁄2”31⁄2”  Optional Finish: -B Polished Brass -C Rough Chrome Plated -D Polished Chrome Plated Female x Female Pressure Restricting Valves - Used with hose rack assemblies. Field-adjustable restricting mechanism reduces water pressure under fl owing conditions (175 PSI max. inlet). When full fl ow is required, restriction can be over-ridden by trained personnel. Female NPT inlet and outlet, 175 PSI, cast brass. 5010/5015 5020/5025 5030/5035 5040/5045 Model No. Size Type 5515 1 1⁄2” Brass 5515P 1 1⁄2” Plastic 5525 2 1⁄2” Brass 5525P 2 1⁄2” Plastic   Threads: NST Other __________ Optional Finish: -B Polished Brass -C Rough Chrome Plated -D Polished Chrome Plated -RL Rocker lugs*Optional: Model No. Size 3315 2 1⁄2” x 11⁄2” Optional Finish: Reducer - Used to change outlet size. Rigid pin lug*, female x male threads.  -B Polished Brass -D Polished Chrome Plated-C Rough Chrome Plated -RL Rocker lugs Threads: NST Other __________ *Optional: Female x Male Angle Valves - Used as fi re hose outlet connections. Female NPT inlet x Male hose thread outlet, 300 PSI, cast brass Model No. Size A B (Open)C D Swing Radius 5010 1 1⁄2” x 11⁄2”4” 7 3⁄4”21⁄4”2” 2 1⁄2” 5015 2 1⁄2” x 21⁄2”51⁄4” 11” 3 1⁄4”23⁄4”31⁄2” Optional Finish: -B Polished Brass -C Rough Chrome Plated -D Polished Chrome Plated Threads:NST Other __________ Female x Male Pressure Restricting Angle Valves - Used as fi re hose outlet connections. Field-adjustable restricting mechanism reduces water pressure under fl owing conditions (175 PSI max. inlet). When full fl ow is required, restriction can be over-ridden by trained personnel. Female NPT x Male hose thread outlet, 175 PSI, cast brass. Model No. Size A B (Open)C D Swing Radius 5030 1 1⁄2” x 11⁄2”4” 8” 2 1⁄4”2” 2 1⁄2” 5035 2 1⁄2” x 21⁄2”51⁄4”111⁄2”31⁄4”23⁄4”31⁄2”  Optional Finish: -B Polished Brass -C Rough Chrome Plated -D Polished Chrome Plated Threads:NST Other __________    DETAIL AND SUBMITTAL SHEETGUARDIAN FIRE EQUIPMENT, INC.MIAMI, FL Ph. 800.327.6584 • Fax 800.827.3869 Project/Location: 5100 Series - Gate Valves Architect/Engineer: Date: Contractor: Qty: *Optional: Model No. Size A B (Open)CDE 5110 2 1/2” x 21/2”51/8”93/4”43/4”17/8”31/2” 5115 3” x 2 1/2”51/8”93/4”45/8”27/8”31/2” A B D C E Appropriate Selection Reducer - Used to change outlet size. Rigid pin lug*, female x male threads. Model No. Size Type 5515 1 1/2” Brass 5515P 1 1/2” Plastic 5525 2 1/2” Brass 5525P 2 1/2” Plastic   Caps with Chains - Used to protect hose thread outlets on valves and hydrants. Cast brass caps (pin lugs)* or red plastic caps (rocker lugs). Female x Male Gate Valves (Non-Rising Stem) - Used on dry systems as fi re hose outlet connections and on pump test manifolds. Female NPT inlet x Male hose thread outlet, solid wedge disc with tapered seats, 300 PSI, cast brass.  Optional Finish: -B Polished Brass -C Rough Chrome Plated -D Polished Chrome Plated Threads:NST Other __________ Optional Finish:-B Polished Brass -C Rough Chrome Plated-D Polished Chrome Plated -RL Rocker lugs Model No. Size 3315 2 1/2” x 11/2” Female x Male Gate Valve (Non-Rising Stem) - Used on dry systems as fi re hose outlet connections and on pump test manifolds. Female hose thread swivel inlet x Male hose thread outlet, solid wedge disc with tapered seats, 300 PSI, cast brass. Model No. Size A B (Open)CDE 5120 2 1/2” x 21/2”51/8”93/4”51/4”17/8”31/2” Optional Finish: -B Polished Brass -C Rough Chrome Plated -D Polished Chrome Plated Optional Finish:  -B Polished Brass -D Polished Chrome Plated-C Rough Chrome Plated -RL Rocker lugs Threads: NST Other __________ *Optional: A B C E D 5110/5115 5120 Threads:NST Other __________ Threads:NST Other __________  DETAIL AND SUBMITTAL SHEET GUARDIAN FIRE EQUIPMENT, INC. MIAMI, FL Ph. 800.327.6584 • Fax 800.827.3869 Project/Location: 2000 Series - Valve Cabinets Architect/Engineer: Date: Contractor: Qty: Model No.Mounting Style Trim A Inside Box Dimensions Frame O.D.* Knockout Location Wall Opening ADA B C D E F G H W H D 2010 Trimless --- 18” 18” 8” --- --- 4” 9” 19” 19” 8 1/2” 2020 Recessed 3/8” 18” 18” 8” 21 1/2” 21 1/2” 4” 9” 19” 19” 8 1/4” 2030 Semi-Rec. 1 1/4” 18” 18” 8” 21 1/2” 21 1/2” 4” 9” 19” 19” 7 1/4” 2040 Semi-Rec. 2 1/2” 18” 18” 8” 21 1/2” 21 1/2” 4” 9” 19” 19” 6” 2050 Surface 9” 21 1/2” 21 1/2” 8 1/2” 21 1/2” 21 1/2” --- --- --- --- --- No Accommodates: 21/2” Fire Dept. Valve Standard Construction & Features: One piece 20 gauge cold-rolled steel door and frame, 18 gauge steel box. Door is reinforced with rigid tubular metal. Continuous steel piano hinge and pin. White baked acrylic enamel fi nish (suitable as prime or fi nish coat). Door handle hardware. *Deduct 3/4” O.D. for aluminum door and frame Appropriate Selection Surface Finished Wall EA/D F Trimless Recessed Semi-Recessed Door Styles Select Contents: Model # _______________ fi re dept. valve Optional Door Lettering: Decals 2513 Fire Dept. Valve, 12” w. x 27/8” h. Die-Cut Letters 2520 Select _________________ WhiteRedBlack VerticalHorizontal All door styles (except -F) furnished standard with clear acrylic inserts, alternate inserts available Option: -SL Safety cam lock (standard on -SSL) -A Full Glass -D Duo Panel -F Solid Panel -V Vertical Duo Panel B C D Finished Wall H G E C D Finished Wall B F A H G E C D Finished Wall B F A H G Fire-Rated Model No.Mounting Style Trim A Inside Box Dimensions Frame O.D.* Knockout Location Wall Opening ADA B C D E F G H W H D FR2020 Recessed 3/8” 18” 18” 8” 21 1/2” 21 1/2” --- --- 20 1/8” 20 1/8” 9 1/8” FR2030 Semi-Rec. 1 1/4” 18” 18” 8” 21 1/2” 21 1/2” --- --- 20 1/8” 20 1/8” 8 1/8” FR2040 Semi-Rec. 2 1/2” 18” 18” 8” 21 1/2” 21 1/2” --- --- 20 1/8” 20 1/8” 7” No Optional Door & Frame Materials: AL Aluminum (clear anodized fi nish) SS 304 Stainless steel (#4 brushed fi nish) B Solid brass doors/frames BZ Bronze doors/frames Add prefi x to model no. to specify -RED Red baked acrylic enamel fi nish (steel cabinets only) Add suffi x to model no. to specify DETAIL AND SUBMITTAL SHEETGUARDIAN FIRE EQUIPMENT, INC.MIAMI, FL Ph. 800.327.6584 • Fax 800.827.3869 Project/Location: 6000 Series - Flush Fire Dept. Inlet Connections Architect/Engineer: Date: Contractor: 31/2” or 41/8” Dia. Swivel Inlet Plug 21/2” or 3”Nipple(by others) Plate 7” 7” Swivel Inlet Plug 31/2” 31/2” or 41/8” Dia. 7” 21/2” or 3”Nipple(by others) Plate 6014/6015 11/2”Nipple (by others) Swivel Inlet Plug 3”43/8” Plate 6002 SwivelInlet 21/2” Nipple(by others) B A A B C Plate 31/2” Dia. 9” 23”D Plug 31/2” Appropriate Selectionoü 6016/6017 Used as auxiliary connections through which the fire department can pump water to supplement existing water supplies. Provides 250 GPM flow (mini- mum), per 21/2” inlet. Single - inlet connections incorporate a straight-thru, non-clappered de- sign with female NPT outlets. Two and three-way inlet connections feature brass bodies (angle or straight pattern), with integral drop-clapper inlets and female NPT outlets. Standard components, all connections: Female hose thread swivel inlets, plugs with chains and identification plate. Cast brass construction, standard. Two and Three-Way Connections Model No.Outlet Size Clappers A B C D 6024 Back 4” x 21/2” x 21/2”2 115/8”77/8”---75/8” 6025 Bottom 4” x 21/2” x 21/2”2 121/8”67/8”71/8”75/8” 6026 Top 4” x 21/2” x 21/2”2 121/8”67/8”71/8”75/8” 6027 Back 6” x 21/2” x 21/2”2 115/8”77/8”---75/8” 6028 Bottom 6” x 21/2” x 21/2”2 121/8”75/8”71/8”75/8” 6029 Top 6” x 21/2” x 21/2”2 121/8”8”9”7” 6034 Back 4” x 21/2” x 21/2” x 21/2”3 173/8”61/8”---65/8” 6037 Back 6” x 21/2” x 21/2” x 21/2”3 173/8”61/8”---65/8” 6038 Bottom 6” x 21/2” x 21/2” x 21/2”3 173/8”75/8”71/8”65/8” 6039 Top 6” x 21/2” x 21/2” x 21/2”3 173/8”75/8”71/8”65/8” Indentification Plate Lettering AUTO SPKR AUTO SPKR & STANDPIPE STANDPIPE DRY STANDPIPE ooooo Single Inlet Connections Model No.6002 6014 6015 6016 6017 Outlet 11/2”21/2”3”21/2”3” Inlet 11/2”21/2”21/2”21/2”21/2” Plate 41/2” O.D.7” O.D.7” O.D.7” SQ 7” SQ Indentification Plate Lettering: AUTO SPKR o o o o o ooooo o o o o 6034-6039 SwivelInlet 21/2” Nipple(by others) B A A B C Plate 31/2” Dia. 9” 15” D 31/2”Plug 6024-6029 Optional Finish: o-C Rough Chrome Plated o-D Polished Chrome Plated -B Polished Brasso 31/2” Contact factory for current listings and approvals Threads: oNST oOther __________ SavingLives through innovation & education • Hilti Firestop Guide 2001 • Hilti U.S.: 1-800-879-8000 / www.us.hilti.com12 Product Information FS-ONE High Performance Intumescent Firestop Sealant Product description •Intumescent (expands when exposed to fire) firestop sealant that helps protect combustible and non-combustible penetrations for up to 4 hours fire rating Areas of application •Steel, copper and EMT pipes •Insulated steel and copper pipes •Cable bundles •Closed or vented plastic pipes •HVAC penetrations For use with •Concrete, masonry, drywall and wood floor assemblies •Wall and floor assemblies rated up to 4 hours Examples •Sealing around plastic pipe penetrations in fire rated construction •Sealing around combustible and non-combustible penetrations in fire rated construction Internationally tested and approved FM APPROVED For Penetration Fire Stops. Consult the Factory Mutual Research Corporation Approval Guide. R C L A SSIFIE D FILL, VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN TROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FS-ONE Intumescent Firestop Sealant Ordering Description Color Package contents Volume Item No. FS-ONE, tube red 10.1 oz. (300 ml) 18 in 3 00259579 FS-ONE, foil red (Qty 20) 20.2 oz. (600 ml) 36 in 3 00311387 FS-ONE, pail red 5 Gallons (19 liter) 1155 in 3 00259578 CB 200 Pl-300/310 ml Dispenser 00055205 600 ml Foil Dispenser 00024669 System advantage/Customer benefits •Protects most typical firestop penetration applications •Easy to work with and fast cleanup •Can be repenetrated when laying new cables •Can be painted 13SavingLivesthrough innovation & education • Hilti Firestop Guide 2001 • Hilti U.S.: 1-800-879-8000 / www.us.hilti.com Installation Instructions FS-ONE High Performance Intumescent Firestop Sealant Product description •Intumescent (expands when exposed to fire) firestop sealant that helps protect combustible and non-combustible penetrations for up to 4 hours fire rating Product features •Smoke, gas and water resistant •Contains no halogen, solvents or asbestos •High fire rating properties •Water based, easy to clean Tested in accordance with •UL 1479 •ASTM E 814 •ASTM E 84 Technical Data FS-ONE Intumescent Firestop (at 73°F (23°C) and 50% relative humidity) Chemical basis: Water-based intumescent acrylic dispersion Density: Approx. 1.5 g/cm 3 Color: Red Working time: Approx. 20-30 min Curing time: Approx. 14-21 days Shore A Hardness: Approx. 35 Movement capability: Approx. 5% Intumescent Activation: Approx 250°F (121°C) Expansion rate (unrestricted): Up to 3-5 times original volume Temperature resistance (cured): -40°F (-40°C) to 212°F (100°C) Application temperature: 35°F (2°C) to 100°F (38°C) Surface burning characteristics: Flame Spread: 0 (ASTM E 84-96) Smoke Development: 5 Sound transmission classification: 50 ASTM E 90-97 Approvals ICBO Evaluation Service, Inc. Report No. 5071 California State Fire Marshal Listing No. 1200:108 City of New York MEA 326-96-M Vol. II 6. Fasten identificationplate (if required).1. Clean opening. 2. Pack mineral wool. (If required) 3. Apply FS-ONE. 4. Smooth FS-ONE. 5. Leave completed seal undisturbed for 48 hours. 6. Fasten identification plate (if required). 1. Clean opening. 2. Pack mineral wool. (If required) 3. Apply FS-ONE. 4. Smooth FS-ONE. 5. Leave completed seal undisturbed for 48 hours. Installation instructions for FS-ONE Cable installation FirestopSystem Opening 1. Clean the opening. Surfaces to which FS-ONE will be applied should be cleaned of loose debris, dirt, oil, moisture, frost and wax. Structures supporting penetrating items must be installed in compliance with local building and electrical standards. Application of firestop sealant 2. Install the prescribed backfilling material type and depth to obtain the desired rating (if required). Leave sufficient depth for applying FS-ONE. 3. Application of firestop sealant: Apply FS-ONE to the required depth in order to obtain the desired fire rating. Make sure FS-ONE contacts all surfaces to provide maximum adhesion. For application of FS-ONE use a standard caulking gun, foil pack gun, bulk loader and bulk gun. With FS- ONE buckets, Graco type sealant pumps may be used. (Contact pump manufacturer for proper selection). 4. Smoothing of firestop sealant: To complete the seal, tool immediately to give a smooth appearance. Excess sealant, prior to curing, can be cleaned away from adjacent surfaces and tools with water. 5. Leave completed seal undisturbed for 48 hours. 6. For maintenance reasons, a penetration seal could be permanently marked with an identification plate. In such a case, mark the identification plate and fasten it in a visible position next to the seal. Notice about approvals •Check that the penetration has been sealed according to the specified drawing in the UL Fire Resistance Directory or Hilti Firestop Manual. For further advice, please contact Hilti customer service. Refer to Hilti product literature and UL fire resistance directory for specific application details. Not for use... •High movement expansion joints •Underwater •On materials where oil, plasticizers or solvents may bleed i.e. impregnated wood, oil based seals, green or partially vulcanized rubber •In any penetration other than those specifically described in this manual or the test reports Safety precautions •Before handling, read the product and Material Safety Data Sheet for detailed use and health information •Keep out of reach of children •Wear suitable gloves and eye protection Storage •Store only in the original packaging in a location protected from moisture at temperatures between 40°F (5°C) and 86°F (30°C) •Observe expiration date on the packaging FirestopSystem Pipe installation SavingLives through innovation & education • Hilti Firestop Guide 2001 • Hilti U.S.: 1-800-879-8000 / www.us.hilti.com210 Material Safety Data Sheet HILTI, INC.: P.O. Box 21148, Tulsa, OK 74121; Ph: 1 800 879 6000; Emergency No.: 1 800 879 4444 PRODUCT NAME: FS-ONE High Performance Intumescent Firestop Sealant MSDS No.: 259 Revision No.: 008 DESCRIPTION: One-part acrylic-based sealant Date: 05/19/99 Page: 1 of 2 INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: PEL: TLV: TEL: Calcium carbonate 01317-65-3 5 mg/m3 (T) 10 mg/m 3 (T) NE Ammonium polyphosphate 68333-79-9 NE NE NE Boron trioxide 01303-86-2 15 mg/m 3 (R) 10 mg/m 3 NE Alkylphenolethersulfate, sodium salt 69011-84-3 NE NE NE Talc 14807-96-6 20 mppcf 2 mg/m3 NE Zinc oxide 01314-13-2 5 mg/m3 (T) 10 mg/m 3 NE Expandable graphite 12777-87-6 5 mg/m3 (T) 2 mg/m 3 (T) NE Ethylene glycol 00107-21-1 NE C:100 mg/m 3 (A) NE Polybutene 09003-29-6 NE NE NE Iron oxide 01309-37-1 10 mg/m 3 5 mg/m3 NE Glass filament 65997-17-3 NE 5 mg/m3 (T) NE Silicon dioxide 14808-60-7 0.05 mg/m 3 (T) 0.1 mg/m 3 (T) NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. C = Ceiling. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. (T) indicates “as total dust”. (R) indicates “as respirable fraction”. (A) indicates “as an aerosol”. mppcf = million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless. Vapor Density: (air = 1) Not determined. Vapor Pressure: 23mbar @ 20C / 68F Boiling Point: Not applicable. VOC Content: None. Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Notdetermined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non-flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting Procedures: None known. Use a self-contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. Thermal decomposition products can be formed. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids, peroxides, and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Carcinogenicity: IARC classifies crystalline silica (quartz sand) as Gp I based upon evidence among workers in industries where there has been long-term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this classification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. 211SavingLivesthrough innovation & education • Hilti Firestop Guide 2001 • Hilti U.S.: 1-800-879-8000 / www.us.hilti.com Material Safety Data Sheet Signs and Symptoms of Exposure: Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Routes of Exposure: Dermal. Medical Conditions Aggravated by Exposure: Eye and skin conditions. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Not required, however, safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact. Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSH-approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool, dry area preferably between 50°and 100°F. Keep from freezing. Do not store in direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label/use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local, state, or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product contains 1-5% ethylene glycol (CAS 107-21-1) and 1-5% zinc oxide (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Emergency: 1 800 879 4444 Health / Safety: 1 800 879 6000 Steve Gerrard (x6309) Jerry Metcalf (x6704) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. SavingLives through innovation & education • Hilti Firestop Guide 2001 • Hilti U.S.: 1-800-879-8000 / www.us.hilti.com234 Certificate of Compliance – FS-ONE