Loading...
HomeMy WebLinkAboutF16-0065 Equipment Data.pdf O di Western States Fire Protection Co. pzarezeieel Irk eta profterti 7026 South Tucson Way Centennial, CO 80112 (303) 792-0022 Fax (303) 792-9049 Fire Protection Equipment Submittal Vail Cascade Remodel 1300 Westhaven Drive Vail, CO 81657 WSFP #CS2893 Prepared by: Bryan Horn,PE Senior Project Manager Western States Fire Protection Co. 7026 South Tucson Way Centennial. CO 80112 (608)215-0568 Email:bryan.horn@wsfp.us Bulletin 014 Rev. N co Reliable MQuickodel F1 FResponseR Series 0 m Q 4, Glass Bulb Sprinklers ap z Model Fl FR56 Sprinkler Types - Standard Spray Upright P ....___ tStandard Spray Pendent Ate. Conventional Upright/Pendent Vertical Sidewall �' P• ' Horizontal Sidewall A I Model Fl FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent 4=_ Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types ciliT- 411111411 * Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Vertical Sidewall Horizontal Sidewall Recessed Standard Spray Upright Pendent/F1/F2 Standard Spray Pendent -- Model Fl FR40 Sprinkler Types Standard Spray Pendent / ., ,� ,; z1 • t Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 ; A. r �' Recessed Sprinkler Types :'' . •�� ' Standard Spray Pendent %' :. + . Model F1 FR56LL & F1 FR42LL NSF Certified Low Recessed Concealed Recessed Lead Sprinkler Types Horizontal Sidewall Pendent Pendent/FP Standard Spray Pendent with less than 0.25% Lead 411410 0 -':41141114 Content Listing & Approvals The following organizations provide Listings or Approvals 44 At; for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on XLH Upright XLH Pendent XLH Recessed specific listings and approvals applicable to each sprin- Pendent F1/F2 kler. 1. Underwriters Laboratories Inc. and Certified for Product Description :� Canada(cULus). Reliable Model F1FR series sprinklers - _ are quick-response automatic sprin- 2. FM Approvals (FM) wf _ � � 3. Loss Prevention Certification Board (LPCB) klers with a glass bulb thermal element. - : -- 4. VdS Schadenverhutung GmbH (VdS) Model F1FR series sprinklers are Stan 5. NSF Certified to NSF/ANSi Standard 61 Annex G dard Spray sprinklers, with the excep (NSF) tion of the Model F1 FR56 Conventional XLH Recessed 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- sprinkler which is an Old-style/Conven- Pendent FP CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) tional sprinkler. (EC) The Model Fl FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb.These sprinklers have demonstrat- UL Listing Category ed response times in laboratory tests which are five to ten Sprinklers,Automatic&Open (VNIV) times faster than standard response sprinklers. This quick Quick Response Sprinkler response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid Model Fl FR Series sprinklers must be installed with the in both the liquid and vapor phases. The vapor phase can Reliable sprinkler installation wrench identified in the Design be seen as a small bubble. As heat is applied, the liquid and Installation Information table in this Bulletin. Any other expands, forcing the bubble smaller and smaller as the liq- wrench may damage the sprinkler. A leak tight sprinkler joint uid pressure increases. Continued heating forces the liquid can be obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). to push out against the bulb, causing the glass to shatter, Do not tighten sprinklers over the maximum recommended opening the waterway and allowing the deflector to distrib- installation torque. Exceeding the maximum recommended ute the discharging water. installation torque may cause leakage or impairment of the Model F1 FR Series sprinklers provide a wide range of op- sprinkler. tions where quick-response, glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal side- Model Fl FR Series Recessed sprinklers are to be installed wall, and vertical sidewall deflectors as shown in Fig. 1, Fig.2,or Fig.3, as applicable to the spe- • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 cific model being installed.The Recessed Escutcheon Data metric), and 5.6 (80 metric) table in the Bulletin identifies the only recessed escutcheons • Flush, recessed, and concealed installations that are permitted to be used with each Model Fl FR Series See the Design and Installation Information table in this Recessed sprinkler.The use of any other recessed escutch- Bulletin for information on the approvals and availability of eon will void all approvals and negate all warranties. specific Model F1 FR series sprinkler configurations. Concealed Sprinklers Model F1FR Recessed Pendent and Recessed Horizon- Model F1FR Series Concealed Pendent sprinklers are to tal Sidewall sprinklers are required to be used with Reliable be installed as shown in Fig.4 or Fig. 5, as applicable to the Model F1, F2, or FP recessed escutcheons. See the Re- selected cover plate. Model F1 FR56 Concealed Pendent cessed Escutcheon Data table in this Bulletin for listing and and Model F1 FR56LL Concealed Pendent sprinklers have approval information with each specific Model F1FR series a factory-installed Model CCP cup. A protective cap is in- sprinkler. Model Fl and F2 recessed escutcheons,shown in stalled at the factory that should remain on the sprinkler until Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch the sprinkler is installed and should then be reinstalled on (19mm) and 1/2-inch (12.7mm)of adjustment, respectively. the sprinkler until the cover plate is installed.The concealed Model FP recessed escutcheons, shown in Fig. 2, provide a sprinkler assemblies are completed by the installation of a 1/2-inch(12.7mm)threaded adjustment. Model CCP push-on/thread-off cover plate assembly. The Model F1 FR56 Concealed Pendent and Model F1 FR56LL cover plate and sprinkler cup assemblies are joined using Concealed Pendent sprinklers are required to be used with a cover plate skirt with flexible tabs for threaded engage- Model CCP cover plates.A standard profile Model CCP cov- ment. A choice of two Model CCP cover plate assemblies er plate is available that provides up to 1/2-inch(12.7mm)of provides either 1/2-inch (13mm) or 5/8-inch (8mm)of cover cover plate adjustment. In addition, a low profile Model CCP adjustment. Do not install Model F1 FR Series Concealed cover plate is also available that provides up to 5/16-inch Pendent sprinklers in ceilings which have positive pressure (8.0mm) of cover plate adjustment. See the Design and In- in the space above. stallation Information and Listed and Approved Temperature Model F1FR Series Concealed Pendent sprinklers require a Ratings tables in this Bulletin for further information on ap- 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The proved cover plate options. Model RC1 wrench is used to engage the sprinkler wrenching Application surfaces and to install the sprinkler in the fitting. Remove the Model F1 FR Series sprinklers are intended for use in protective cap to install the sprinkler,then reinstall the protective accordance with NFPA 13, FM Property Loss Prevention cap until the cover plate is installed. When inserting or remov- Data Sheets, and the requirements of the Authority Hav- ing the wrench from the sprinkler/cup assembly,care should be ing Jurisdiction. Care must be exercised that the k-factor, taken to prevent damage to the sprinkler. Do not wrench any temperature rating, deflector style, and sprinkler type are other part of the sprinkler/cup assembly. Installation is corn- in accordance with the requirements of the applicable pleted by removing the protective cap from the sprinkler and design and installation standards. In addition, Model pushing the cover plate onto the cup. Final adjustment is made F1 FR Series sprinklers must be used in accordance with by hand turning the cover plate until the skirt flange makes full their listings and approvals, as well as the information contact with the ceiling.Cover plate removal requires turning the provided in this Bulletin. cover plate in the counter clockwise direction.After installation, Installation inspect all sprinklers to ensure that there is a gap between the Glass bulb sprinklers have orange bulb protectors or pro- cover plate and ceiling and that the four cup slots are open and tective caps to minimize bulb damage during shipping,han- free from any air flow impediment to the space above. dling and installation. Reliable sprinkler installation wrench- Concealed cover plate/cup assemblies are listed only for es are designed to install sprinklers with bulb protectors in use with specific sprinklers.The use of any concealed cover place. Remove the bulb protector at the time when the sprin- plate/cup assembly other than the Reliable Model CCP with kler system is placed in service for fire protection. Removal Model F1 FR56 Concealed Pendent and Model F1 FR56LL of the bulb protector before this time may leave the bulb vul- Concealed Pendent sprinklers or the use of the Model CCP nerable to damage. Remove bulb protectors by undoing the Concealed cover plate assembly on any sprinkler with which clasp by hand. Do not use tools to remove bulb protectors. it is not specifically listed my prevent good fire protection and will void all guarantees,warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414& RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal Orifice Deflector/ Sprinkler Installation Listings Approval Model K-factor Diameter Orientation Height Wrench SIN and Notes US Metric inches mm inches mm Approvals Pendent 2.25 57 D RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 Pendent 2.25 57 D RA1418 VdS F1 FR40 4.0 57 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 D RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 Pendent 2.25 57 D RA1410 cULus, NSF F1FR42LL 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1 FRXLH Pendent 2.25 57 D RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 2.25 57 D RA1423 cULus 1,2 Pendent 2.25 57 D RA1414 cULus, FM, 1,2,3,4 LPCB,VdS, EC Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, 1,2,3,4 LPCB,VdS, EC F1FR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 cULus, FM, 1,2,3,4 LPCB,VdS, EC "Conventional 2.25 57 D RA1475 LPCB,VdS, EC 4 (Pendent or Upright)" Pendent 2.25 57 D RA1415 cULus, NSF _ 1 F1FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 GFR2 RA1435 cULus, FM 8 Sidewall F1FR56 5.6 80 1/2 15 Vertical Sidewall 2 25 57 D RA1485 cULus, FM, 1,2,3,9 (Pendent or Upright) LPCB _ (1)cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3)Available with FM approved Polyester coating in black or white. (4)Available with LPCB and VdS approved Polyester coating. (5)VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (6)Model Fl FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. (7)cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (8)cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. >9>The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches(102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector/ 100PF(38PC)Max.Ambient 150PF(65PC)Max.Ambient 225PF(107PC)Max. Model Orientation Temp. Temp. Ambient Temp. 135PF(57PC) 155PF(68PC) 175PF(79PC) 200PF(93PC) 286PF(141PC)Temp. Temp. Rating Temp. Rating Temp. Rating Temp. Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1 FR28 Recessed Pendent cULus -- Upright cULus F1 FR40 Pendent VdS Recessed Pendent VdS -- Pendent cULus F1FR42 Recessed Pendent cULus -- Upright cULus F1FR42LL Pendent -- cULus, NSF -- Recessed Pendent -- cULus, NSF -- Pendent cULus F1FRXLH Recessed Pendent cULus -- Upright cULus Pendent cULus, FM, LPCB,VdS, EC Recessed Pendent cULus, FM, LPCB,VdS, EC -- F1FR56 Concealed Pendent" cULus cULus,VdS,EC cULus -- Upright cULus, FM, LPCB,VdS, EC "Conventional LPCB,VdS, EC (Pendent or Upright)" Pendent -- cULus, NSF -- F1 FR56LL Recessed Pendent -- cULus, NSF -- Concealed Pendent" -- cULus, NSF -- Horizontal Sidewall cULus, FM F1FR56 Recessed Horizontal Sidewall cULus, FM -- F1FR56 Vertical Sidewall (Pen cULus, FM, LPCB dent or Upright) * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F(74°C)temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model F1 Model F2 Model FP Model Orientation (Fig. 1 &3) (Fig. 1 &3) (Fig.2) SIN 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS Vd5 RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB,VdS, cULus, FM, LPCB, cULus,VdS, EC RA1414 EC VdS, EC F1 FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. 2 1/4"HOLE DIA. [57.2mm] 1 15/16"DIA [49.2mm] L- 1" X 1/2" REDUCER TURN COLLAR IT J UNTIL TIGHT AGAINST SPRINKLER I WRENCH BOSS \ \ / FACE OF FITTING TO FACE OF CEILINGGDIMENSION \ / Fl ESCUTCHEON AT MAXIMUM RECESS = 1'1-25.4mm] �� SII L J AT MINIMUM RECESS = 3/8'[9.5mm] F1 ESCUTCHEON F2 ESCUTCHEON �' AFI �I�; AT MAXIMUM RECESS = 3 4 19mm 3/4"[19m m] ���� i ��� � � / '( ] ADJUSTMENT „ AT MINIMUM RECESS = 3/8[9.5mm F2 ESCUTCHEON 03SVEI itIr 1/2" 12.7mm11j ADJUSTMENT \ ' `� Fl ESCUTCHEON ;tI I I/8" AT MAXIMUM RECESS = 7/8"[22.2mm] %it 1, [3.2,77m, /AT MINIMUM RECESS = 1-5/8[41.3mm] F2 ESCUTCHEON `* ;,&/ AT MAXIMUM RECESS = 1-1/8'[28.6mm] 1 PAT MINIMUM RECESS = 1-5/8[41.3mm] 2 27/32"DIA. [72.2mm] Fig. 1 Model F1 FR56,F1 FR56LL, F1 FR42, F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon L � I I 1" X 1/2" REDUCER 2 5/8" DIA. [66.7mm] HOLE IN CEILING 2 5/16" DIA. [58.7mm] CUP r L J CEILING '_-=.MR FACE OF FITTING TO FACE OF CEILING 111111.11111_= ;�; DIMENSION �fll is AT MAXIMUM RECESS = 1-1/2[38mm] ___ _I lif 1I li�l AT MINIMUM RECESS = 1'[25.4mm] 1 ! I • ,\�; w AT MAXIMUM RECESS = 9/16[14.3mm] f `1 %2"[12.7mmJ '�!„!�` AT MINIMUM RECESS = 1725.4mm] ADJUSTMENT • 3 1/4" DIA. t [82.6mm] Fig.2 Model Fl FR56, F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON j/ A AT MAXIMUM RECESS = 1'[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] Fl ESCUTCHEON F2 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8[34.9mm] AT MAXIMUM RECESS = 3/4'[l9mm] AT MINIMUM RECESS = 2-1/16152.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'[41.3mm] 2 1/4" HOLE DIA. 1/8„ AT MINIMUM RECESS = 2-1/16'[52.4mm] [57.2mm] ` [3.2mm] 1" X 1/2" REDUCER r - m 1 i -,r-� - Illi - -r,1 4»-12" (1) l r_1 Illl�l 111111l! �11 1 15/16" DIA. /um \. xlx }�_, (101.6mm-304.Smm) [49.2mm] iiiii Iilllllllllllll. i; 2 27/32" DIA. CEILING TO 0°I [72.2mm] DEFLECTOR `_Ilylll /_-L_1A �i Y TURN COLLAR UNTIL � TIGHT AGAINST SPRINKLER WRENCH BOSS. F1 ESCUTCHEON 3/4'[l9mm] ADJUSTMENT �_- F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT 01 RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW - - L - - n ----1--- r--- 2 5/8" DIA. 2 5/16" DIA — HOLE IN CEILING CUP ,>, =-- r i�I ®�°�] ,., 1 1/2" MAX. ;;;;;� III,. o II iiii�iiii; j �1�IFACE OF FITTING TO FACE OF CEILING �`- itl "1 III DIMENSION CEILING ���� ���� �;������� 1 • ` ' ,' 1/2" MAX. COVER ADJUSTMENT COVER PLATE ASSEMBLY3 5/16" DIA. SPRINKLER / CONCEALED, 1/2" ADJUSTMENT O17FGO1A Fig.4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch(12.7mm)adjustment-Model CCP cover plate 6. 1" x 1/2" REDUCING TEE OR ELBOW J IT I + r}} � 1--, L 2 5/8' DIA. 2 5/16" DIA — HOLE IN CEILING L_ J CUP ;—'1 ,t-- ii-1 t, I 1 1/2 MAX. FACE OF FITT/NG TO FACE OF CEILING I�������� DIMENSION CEILING --• ' i 5/16" MAX. .--=.... 3/4" COVER ADJUSTMENT COVER PLATE / } ASSEMBLY 3 5/16" DIA. SPRINKLER CONCEALED, 5/1 6" ADJUSTMENT 01 7FGO2A Fig.5-Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch(8.0mm)adjustment-Model CCP cover plate Maintenance Material Data The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA Frame: DZR Brass, QM Brass,or Low Lead Brass 25. Do not clean sprinklers with soap and water,ammonia or Deflector: CDA Alloy 220, 260,or 510 any other cleaning fluids. Remove dust by using a soft brush Load Screw\Pintle: CDA Alloy 360 or 544 or gentle vacuuming. Replace any sprinkler which has been painted(other than factory applied)or damaged in any way. Cup: CDA Alloy 651 or 693 A stock of spare sprinklers should be maintained to allow Washer: Nickel Alloy 440 or 360, coated with PTFE quick replacement of damaged or operated sprinklers. Adhesive Tape Finishes ft) Bulb: Glass Standard Finishes Sprinkler Escutcheon Cover plater') Bronze Brass Chrome Ordering Information Chrome Plated Chrome White Specify: Polyester Plated 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] Coated(4)(5)(6) White Painted [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Special Application Finishes 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Sprinkler Escutcheon Cover plate(') Pendent][Upright][Conventional][Horizontal Sidewall] Electroless Nickel Electroless Nickel Brass Bright [Recessed Horizontal Sidewall Vertical Sidewall] PTFE') PTFE g 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Bright Brass3 Bright Brass Black Plating Black Plated Black Plated Black Paint 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F Black Painto)c6t Black Paint Off White (68°C)][175°F(79°C)][200°F(93°C)][286°F(141°C)] Off White2>(6) Off White Satin Chrome 5. Sprinkler Finish Chrome Dull Chrome Dull 6. Escutcheon Model: [F1][F2][FP] (1)Other finishes and colors are available on special order. Consult the 7. Escutcheon Finish (where applicable) factory for details.Custom color painted sprinklers may not retain their 8. Cover plate Model: [standard profile CCP 1/2-inch UL Corrosion resistance listing.Coverplate custom paint is semi-gloss, (12.7mm) adjustment][low profile CCP 5/16-inch unless specified otherwise. (2) cULus Listed only. (8.0mm) adjustment] (3) 200°F(93°C)maximum. 9. Cover plate Temperature Rating: [135°F(57°C)for use (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 with Ordinary Temperature sprinklers][165°F (74°C) (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and for use with Intermediate Temperature sprinklers] RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. 10. Cover plate Finish (5) FM Approvals finish as"Polyester coated"applies to SIN Number RA1414,RA1435 and RA1425 in standard black or white. Note: When Model F1 FR Series Recessed sprinklers are ordered, the (6)LPCB and VdS Approved finish applies only to RA1425, RA1414,RA1418 sprinklers and escutcheons are packaged separately. (VdS)and RA1475. (7)cULus listed Corrosion Resistant 7. Bulletin 148 Rev.G Model Fl FR QREC Series CO CD Reliable° K8.0 (115 metric) Quick Response Extended 5;co. Coverage Sprinklers , A complete line of UL Listed and FM Approved quick response extended coverage sprinklers for light hazard applications. , \ Horizontal Sidewall Sprinklers are approved for installation 4" - 12" (102mm - 305mm) below the ceiling. I ^ Model Fl FR QREC Sprinkler Types Extended Coverage Pendent Extended Coverage Horizontal Sidewall Extended Coverage Recessed Extended • EC-9 Deflector Pendent Coverage Pendent Model Fl FR QREC Recessed Sprinkler Types Recessed Extended Coverage Pendent Recessed Extended Coverage Horizontal ' Sidewall: • EC-9 Deflector For Model Fl FR QREC 1/2" K 5.6 (80) Sprinkler Types refer to Bulletin 028. Extended Coverage Recessed Extended Horizontal Sidewall EC-9 Coverage Horizontal Sidewall Approval Organizations EC-9 1. Underwriters' Laboratories, Inc. (UL) 2. Underwriters Laboratories of Canada(ULC) 3. Factory Mutual Approvals (FM) 4. NYC MEA 258-93-E UL Listing Category The glass bulb consists of an accurately controlled amount Sprinklers, Automatic & Open of special fluid hermetically sealed inside a precisely manu- Quick Response Extended Coverage Sprinkler factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of UL Guide Number parts are made of brass, copper and beryllium nickel. VN IV The temperature rating of the sprinkler is identified by the Note:Consult appropriate FM Installation Standards color of the glass bulb. regarding limitations of room size, ceiling height and Application minimum wall fire resistance rating. Product Description Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be Reliable Models F1FR QREC and F1FR QREC Recessed exercised that the orifice size, temperature rating, deflector Sprinklers are quick response sprinklers which combine the style and sprinkler type are in accordance with the latest durability for a standard sprinkler with the attractive low pro- published standards of the National Fire Protection Asso- file of a decorative sprinkler. ciation or the approving authority having jurisdiction. Quick The Models Fl FR QREC and Fl FR QREC Recessed Auto- response sprinklers are intended for installation as specified matic Sprinklers utilize a 3.0mm frangible glass bulb. These in NFPA 13. sprinklers have demonstrated response times in laboratory tests which are five times faster than standard response sprinklers. This quick response enables these sprinklers to apply water to a fire faster than standard response sprinklers of the same temperature rating. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model Fl FR QREC Pendent Sprinkler Deflector: EC Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage-Light Hazard Occupancy ., Installation Data: li hug PI Nominal Sprinkler Nominal Thread K-Factor Sprinkler Temperature Approval Orifice Size Length Rating Organizations Identification US Metric Number(SIN) 111, 17/32" 3/4" NPT 8.0 115 2.2" 135°F(57°C) 1,2,3,4 R4842 (20mm) (R3/4) (56.1mm) 155°F(68°C) Model Fl FR QREC Recessed Pendent Sprinkler Deflector: EC Installation Wrench: Model GFR2 Sprinkler Wrench Approval Type: Quick Response Extended Coverage-Light Hazard Occupancy Installation Data: Nominal S rinkler Nominal Thread K-Factor Sprinkler Temperature Approval)" p Orifice Size US Metric Length Rating Organizations Identific(tio) Number SIN 17/32" 3/4" NPT 8.0 115 2.2" 135°F(57°C) 1, 2, 3, 4 R4842 (20mm) (R3/4) (56.1mm) 155°F(68°C) (I)Refer to escutcheon data table for dimensions. Model Fl FR QREC Pendent and Recessed Pendent Required Minimum Flow/Pressure — Maximum Flow Rate Pressure Coverage Area 2 1/4"HOLE D/A. gpm (L/min) psi (bar) Width x Length [57.15mm] 1 15/16"DIA ft.x ft. (m x m) f [49.21mm] 26 (98.4) 10.6(0,7) 16 x 16 (4.9 x 4.9) r — 33 (125.0) 17.0(1,2) 18x18 (5.5x5.5) _ _ "x3/4"REDUCER TURN COLLAR HI - OR UNTIL TIGHT 1"X 1/2"REDUCER 40 (151.4) 25.0(1,7) 20 x 20 (6.0 x 6.0)(2) AGAINST SPRINKLER WRENCH BOSS _ _ (2)UL/ULC Listed for both Pendent and Recessed Pendent at I I FACE OF FITTING TO 135°F(57°C)only. 11 C==: II CEILING DIMENSION(2) JLy ' 4W 17�iv L'I. 1/8". ADJUSTMENT(2) Q i[3.18mm] • .A"(2) ,11 2 27/32 DIA. [72.23mm] 136FGO2B 2. Model F1 FR QREC Horizontal Sidewall Sprinkler Deflector: EC-9 Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage-Light Hazard Occupancy Installation Data Nominal Sprinkler Nominal Thread Sprinkler Approval(2) Temperature K-Factor ,; , Orifice Size Length Organizations Rating Identification US Metric Number(SIN) 135°F (57°C) "/32" 3/4"NPT 8.0 115 2'85 1,2,3,4 155°F (68°C) R4862 (20mm) (R34) (72.4mm) 175°F (78°C) Model Fl FR QREC Recessed Horizontal Sidewall Sprinkler Deflector: EC-9 Installation Wrench: Model GFR2 Sprinkler Wrench Approval Type: Quick Response Extended Coverage-Light Hazard Occupancy Model Fl FR QREC Horizontal Sidewall and Recessed Horizontal Sidewall Required Minimum Flow/Pressure Flow Rate Pressure Maximum Approvalm Deflector to Ceiling gpm(L/min) psi(bar) Coverage Area Temperature Organizations _ Dimension Width x Length Rating') Min.-Max. UL FM UL FM ft.x ft.(m x m) Fl F2 Inches(mm) 26 (98.4) - 10.6 (0,7) - 16 x 16 (4.9 x 4.9) 135°F (57°C) 6-12 (153-305) 29 (109.8) 32 (121.1) 13.1 (0,9) 16.0 (1,1) 16x16 (4.9x4.9) 4-12 (102-305) 29 (109.8) 36 (136.3) 13.1 (0,9) 20.2 (1,4) 16 x 18 (4.9 x 5.5) 155°F (68°C) 1,2,4 1,2,3,4 4-12 (102-305) 32 (121.1) 40 (151.4) 16.0 (1,1) 25.0 (1,7) 16x20 (4.9x6.0) 4-12 (102-305) 36 (136.3) 44 (166.6) 20.2 (1,4) 30.2 (2,1) 16 x 22 (4.9 x 6.7) 175°F (78°C) 4-12 (102-305) 39 (147.6) 48 (181.7) 23.8 (1,6) 36.0 (2,5) 16 x 24 (4.9 x 7.3) 4-12 (102-305) 33(124.9) 17.0(1,2) 18 x 18(5.5 x 5.5) 135°F (57°C) 4- 12(102-305) 39(147.6) 23.8(1,6) 14 x 26(4.3 x 7.9) 135°F (57°C) 4-6(102- 153) 40(151.4) 25.0(1,7) 18 x 22(5.5 x 6.7) 135°F (57°C) 4- 12(102-305) 46(174.1) 33.1 (2,25) 14 x 26(4.3 x 7.9) 135°F (57°C) 1,2 1,2 6- 12(153-305) 33(124.9) 17.0(1,2) 18 x 18(5.5 x 5.5) 155°F (68°C) 4-12(102-305) 40(151.4) 25.0(1,7) 18 x 22(5.5 x 6.7) 155°F (68°C) 4- 12(102-305) 46(174.1) 33.1 (2,25) 14 x 26(4.3 x 7.9) 155°F (68°C) 6- 12(153-305) (I)FM Approval of recessed sprinkler-135°F(57°C)and 155°F(68°C)only. (2)Refer to escutcheon data table for dimensions. (2) FEINFDFIMNOTNO 1/8" `.\ 4"TO 72' _- TURN SPRING COLLAR. MI11M1 UNTIL TIGHT AGAINST - I � SPRINKLER WRENCH BOSS. IIIIIIIIIIII�' 2 27/32"DIA I /5/,6" 1171117111 -RECOMMENDED WALL HOLE A"(2) 2 1/4"DIAMETER 159FG02 ADJUSTMENT(2I 148E6'02 3. Installation Sprinkler Types Quick response sprinkler are intended for installation as Extended Coverage Pendent specified in NFPA 13. Quick response sprinklers and stan- Extended Coverage Sidewall dard response sprinklers should not be intermixed. • EC-9 HSW Deflector The Model Fl FR QREC Recessed Sprinklers are to be in- Recessed Extended Coverage Pendent stalled as shown. The Model Fl or F2 Escutcheons illus- Recessed Extended Coverage Sidewall trated are the only recessed escutcheons to be used with • EC-9 HSW Deflector the Model F1FR QREC Sprinklers. The use of any other Finishes(1) recessed escutcheon will void all approvals and negate all Standard Finishes(1) warranties. Sprinkler Escutcheon When installing Model F1FR QREC Sprinklers, use the Bronze Brass Model D Sprinkler Wrench. When installing Model F1FR Chrome Chrome QREC Recessed Pendent or Recessed Sidewall Sprinklers, White&Black Polyester(3) White use the Model GFR1 Sprinkler Wrench. Any other type of Special Application Finishes wrench may damage these sprinklers. Sprinkler(2) Escutcheon Glass bulb sprinklers have orange bulb protectors to Electroless Nickel PTFE(3) Electroless Nickel PTFE minimize bulb damage during shipping, handling and in- Bright Brass Bright Brass stallation. REMOVE THIS PROTECTION AT THE TIME THE Black Plating Black Plating SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE Black Paint Black Paint Off White Satin Off White PROTECTION. Removal of the protectors before this time Chrome Chrome Dull may leave the bulb vulnerable to damage. RASCO wrench- (1)Other colors and finishes are available on special order. Consult es are designed to install sprinklers when covers are in factory for details. place. REMOVE PROTECTORS BY UNDOING THE CLASP (2)FM Approval limited to bronze,bright and satin chrome plated, BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- and polyester coated only. (3)cULus Listed Corrosion Resistant Sprinkler TECTORS. Maintenance Escutcheon Data The Models Fl FR QREC and Fl FR QREC Recessed Sprin- Face of Fitting klers should be inspected and the sprinkler system main- Model" Adjustment Dimension to Ceiling or tained in accordance with NFPA 25. Do not clean sprinklers Wall Dimension with soapand water, ammonia or anyother cleaningfluids. Fl 3/4" 19mm 3/4"(19mm)1> 3/,s'(5mm) ( ) 13/s"(35mm))2) 15/16"(24mm) I Remove dust by gentle vacuuming. Replace any sprin- kler which has beenpainted (other than factoryapplied) or F2 1/2" 13mm 1" (25mm)1 3/,s'(5mm) pp ) ( ) 19/16"(40mm))2) 1v16'(18mm) damaged in any way. A stock of spare sprinklers should be n>EC Pendent maintained to allow quick replacement of damaged or op- (2)Ec Hsw erated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used Ordering Information to minimize the potential for damage to sprinklers that would Specify: cause improper operation or non-operation. 1. Sprinkler Model: F1FR QREC 2. Sprinkler Type Temperature Ratings 3. Temperature Rating Sprinkler Maximum 4. Sprinkler Finish Classification Rating Ambient Temp. Bulb 5. Thread Type: [3/a" NPT] [ISO 7-1R3/4] NF WC P'F pC Color 6. Escutcheon Type Ordinary 135 57 100 38 Orange 7. Escutcheon Finish (where applicable) Ordinary 155 68 100 38 Red Note: When Model F1FR Recessed sprinklers are or- Intermediate 175 79 150 66 Yellow p dered, the sprinklers and escutcheons are pack- Maximum Working Pressure aged separately. 175 psi (12 bar) SIN R4842&R4862 cULus listed for 250 psi (17 bar) 100% Factory tested hydrostatically to 500 psi(34.5 bar) The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured b Reliable Automatic Sprinkler Co.,Inc. Recycled ® (800)431 1588 Sales Offices Paper eIiabI (800)843481---61505881 48 6051 Sales Fax (914)829 2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.12/15 P/N 9999970142 Bulletin 051 Rev. B DJ ® Model G5-56 Dry(SIN RA5114) -- lieliabl K5.6 (80 metric) Concealed Dry Pendent Sprinkler UL Quick Response FM Standard Response 1" (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Solid or perforated cover plate available in chrome , y and white as Standard Finishes. Also available in a wide variety of Special Application Finishes. :; - 3. Cover plates with gaskets are available to limit dust and air movement through the ceiling. 4. Available in Ordinary or Intermediate temperature rating. 5. Sprinkler available in lengths from 41/4 inches (108mm) to 48 inches (1219mm) in 1/4-inch (6.35mm)increments(see Fig. 1). Approvals & Listings 1. Listed by Underwriters Laboratories and Certified for Model G5-56 Dry Sprinkler Canada(cULus)as a Quick-response sprinkler for Light sealing washer to move out of the inlet orifice admitting water and Ordinary Hazard occupancies. UL Guide Number from the supply piping.The sprinkler uses a fast-response fus- VNIV, Sprinklers, Automatic and Open. ible element with an Ordinary, 165°F (74°C), or Intermediate, 2. FM Approved as a Standard-response sprinkler. 212°F(100°C),temperature classification. Patents The Model G5-56 Dry sprinkler has a dropdown deflector The Model G5-56 Dry is covered by the following patents: design that allows the sprinkler to be recessed into the ceiling U.S. 5,775,431 and concealed by a flat cover plate.The cover plate assembly U.S. 5,967,240 threads into the sprinkler's cup and provides 1-inch(13mm)of cover adjustment. The cover plate assembly consists of a flat Application cover plate that is attached to the skirt using either 135°F(57°C) The Model G5-56 Dry is a cULus Listed Quick Response or 165°F (74°C) temperature rated solder. The 135°F (57°C) Concealed Dry Pendent sprinkler intended for use in accor- cover plates are for use with Ordinary temperature classifica- dance with NFPA 13.The Model G5-56 Dry sprinkler is cULus tion sprinklers and the 165°(74°C)cover plates are for use with Listed for use in Light and Ordinary Hazard occupancies. Intermediate temperature classification sprinklers. The Model G5-56 Dry is FM Approved as a Standard Re- The Model G5-56 Dry sprinkler is available in lengths rang- sponse Concealed Dry Pendent sprinkler intended for use in ing from 41/4 inches(108mm)to 48 inches(1219mm)in'/4-inch accordance with FM Loss Prevention Data Sheet 2.0. (6.35mm) increments (see Fig. 1). The length of the sprinkler Product Description must be selected to provide the Exposed Minimum Barrel Length in a Heated Area required by Fig.2. The Reliable Model G5-56 Dry sprinkler is a Dry Pendent The Model G5-56 Dry sprinkler is available with 1-inch NPT sprinkler, where the sealing washer is located at the inlet end or ISO 7-1 R1 threaded inlet fittings.The standard inlet fitting in- of the sprinkler assembly. The position of the sealing washer is cludes a long inlet designed to minimize the potential for water, controlled by a fusible element at the opposite end of the sprin- scale,and sediment to accumulate on the sprinkler inlet in wet- kler assembly.The sprinkler is installed with the fusible element and dry-pipe sprinkler systems. For wet-pipe sprinkler system at the ceiling of a protected space that may be subject to freez- applications where the standard inlet interferes with installation ing temperatures and the inlet orifice located in a heated area into existing plastic pipe fittings,an inlet fitting is available with a above the ceiling. Operation of the fusible element allows the short("PL")inlet.See Fig.3 for further information. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data: Temperature Rating Nominal Orifice Size: '/2-inch (15mm) Max. Thread Size: 1-inch NPT per ANSI B2.1 or ISO 7-1 R1 Classification Sprinkler Cover Ambient Nominal K Factor: 5.6 (80 metric) Plate Temp. Maximum Working Pressure: 175 psi (12 bar) - 100% Ordinary 165°F(74°C) 135°F(57°C) 100°F(38°C) factory hydrostatically tested to 500 psi (34.5 bar) Sprinkler Installation Wrench: Model FC wrench Intermediate 212°F(100°C) 165°F(74°C) 150°F(66°C) Sprinkler Identification Number (SIN): RA5114 Materials: See Fig. 4 I--- s7 1 II I I I it � I i i i�� �� Ae II - ar Ls zJ 1 MEM I \ A 11111 LL__ _ iSystem Fitting Inlet Threads D 2-5/8" [67 mm] Dia. Hole in Ceiling "A" Dimension 2-5/16" Sprinkler [59 mm] Cup Assembly Nominal Position 1/2" [12 mm] of Cover Plate Total Cover Plate Adjustment kf Cover Plate _l I f �1 ,��unli%�Ipm�_ , 1/4" [6 mm] Assembly =� re ��- i ��i/I_ Cover Plate Adjustment AllEl I ICeiling r..... , \41 A 114" [6mm] Min.to 114" [6mm] 051FGO1B 5/8" [16 mm] Max. Cover Plate Adjustment Dropped Deflector to Ceiling Figure. 1 Note:The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI B2.1 [71/2 threads approximately]. "A" Dim. 41/4"to 48"(108mm to 1219mm)in 1/4"(6.35mm)increments 2. Cover Plate Finishes pipe sprinkler systems. The Model G5-56 Dry sprinkler and Standard Finishes the cover plate assembly are not intended for installation in White Paint corrosive environments, including, but not limited to, those Chrome with salt aerosols or chlorine. Special Application Model G5-56 Dry sprinklers must be installed with the Ex- Finishes posed Minimum Barrel Length required by Fig. 2 located in Off White Paintad a Heated Area. Do NOT install the sprinkler in ceilings which Black Paint app have positive pressure in the space above. Custom Color Paint—Specifyo1 The following steps must be followed for Raw Brass(Lacquered) Bright Brass installation: Finished Bronze Model FC 1. Cut a 25/-inch (67mm) diameter hole in the ceiling di- Black Plated Sprinkler Wrench rectly in-line with the outlet of the tee. Satin Chrome 2. Apply pipe joint compound or Polytetrafluoroethylene Stainless Steel Clad(2) (PTFE)tape to the threads of the sprinkler's inlet fitting. Custom color paint is semi gloss,unless specified otherwise. 3. A protective cap is provided to protect the drop-down (2) Stainless steel clad cover plates are Type 316 Stainless Steel on the finished sprinkler deflector from damage which could occur dur- side and C102 Copper Alloy on the back side.Cover plates are not listed ing construction before the cover plate is installed. The or approved as corrosion resistant.Stainless steel clad cover plates are not cap is factory installed inside the sprinkler cup. Remove available perforated. the cap to install sprinkler,Step 4,then reinstall cap until Optional Cover Plate with Gasket* the cover plate is installed. 4. Install the sprinkler in the tee using the Model FC wrench.The Model FC wrench has a socket drive which is inserted into the sprinkler's cup and around the body of the sprinkler prior to installation of the sprinkler. Do NOT wrench any of the part of the sprinkler/cup assem- bly. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to maximum installation torque is 22-30 lb-ft (30—40 N-m). When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken Model G4 OR Gasket Model G4 SR Gasket to prevent damage to the sprinkler. Reinstall the protec- Cover Plate Cover Plate tive cap following installation of the sprinkler, until the (cULus Listed) (FM Approved) cover plate is installed. a. Alternatively,where access to the outer tube of the *Model G4 QR Gasket and Model G4 SR Gasket cover plates sprinkler is available, the Model G5-56 Dry sprin- are sold as assembled units including both the cover plate and kler may be installed using a pipe wrench. The gasket. Model G4 QR Gasket and Model G4 SR Gasket cover protective cap should not be removed to install plates and gaskets are not interchangeable. the sprinkler with a pipe wrench. The pipe wrench Installation Instructions shall only be permitted to interface with the steel Model G5-56 Dry sprinklers must only be installed in stan- outer tube portion of the sprinkler (Item #8 in dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) Fig. 4). Do NOT wrench any other portion of the pipe tees in the horizontal position,even at branch line ends. sprinkler/cup assembly. A pipe wrench can install the sprinkler into the fitting with a large amount Model G5-56 Dry sprinklers shall not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. of torque; consideration should be given to the In all installations, including into CPVC piping,the dry sprin- need for future removal of the sprinklers because the installation torque will have to be matched or kler shall be installed with protrusion into the fitting in accor- recom- dance with the installation diagrams in this Bulletin. exceeded to remove the sprinkler. The Installation of the Model G5-56 Dry sprinkler is not recom- mended minimum to maximum installation torque mended in copper pipe systems, as this may reduce the is 22-30 lb-ft(30—40 N-m). 5. life expectancy of the sprinkler. Do not install Model G5-56 To install the cover plate, remove the protective cap and Dry sprinklers with the standard(long)inlet fitting into CPVC install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceiling. For adapter fittings or tees that have an internal obstruction(see Model G4 OR Gasket and Model G4 SR Gasket cover Fig. 3); this will damage the sprinkler, the fitting, or both. A short inlet("PL")version of the Model G5-56 Dry sprinkler is plates, the gasket should be attached to the flange of the cover plate skirt only.Do not glue the gasket in place available for use in existing installations with CPVC adapter fittings or tees having an internal obstruction; Model G5-56 the flaoralnge gasket to overlap both the cover plate and sprinklers with the short inlet fitting shall not be used on dry- 3. gee of the skirt. 3. RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER WET PIPE INTO THE 1 INCH NPT SIDE OUTLET EXPOSED BARREL OF A MALLEABLE IRON TEE FITTING AMBIENT AMBIENT TEMPERATURE rt s PER ANSI B 16.3(CLASS 150) TEMPERATURE =__=i"I -� -r-- � -„, OR CAST IRON THREADED TEE FITTING OF PROTECTED 40°F/4°C I 50°F/10°C I 60°F/16°C I,,i PER ANSI 16.4(CLASS 125)ONLY. AREA*AT THE EXPOSED MINIMUM BARREL LENGTH** 4,- IIIIII--- - -111111 - DISCHARGE END OF THE SPRINKLER (FACE OF TEE TO TOP OF CEILING) °LL �I�-- L__-hk-__ J� IN.(MM) IN.(MM) IN.(MM) ) IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 40°F(4°C) 0 0 0 1-__ —_1 CAUSE CONDENSATION ON THE EXPOSED 30°F(-1°C) 0 0 0 IN ER WRAPPING THE EERY SPRINKLER,XPOSED BARREL WITH DINSULATION,FOAM 20°F(-7°C) 4(100) 0 0 `-_= INSULATING TAPE OR EQUIVALENT. 10°F(-12°C) 8(200) 1(25) 0 0°F(-18°C) 12(300) 3(75) 0 MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE EXPOSED AROUND THE SPRINKLER TO AVOID -10°F(-23°C) 14(350) 4(100) 1(25) BARREL LEAKAGE OF AIR INTO THE PROTECTED -20°F(-29°C) 14(350) 6(150) 3(75) LENGTH AREA AND CONSEQUENT FORMATION OF -30°F(-34°C) 16(400) 8(200) 4(100) CLEARANCE CONDENSATE AROUND THE FRAME,WHICH HOLE COULD INHIBIT OPERATION OR CAUSE -40°F(-40°C) 18(450) 8(200) 4(100) PREMATURE OPERATION.SEE BELOW FOR RECOMMENDED METHODS. .A, -50°F(-46°C) 20(500) 10(250) 6(150) DIMENSION -60°F(-51°C) 20(500) 10(250) 6(150) III mil *FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. ' j� . ////////A **THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE'A'DIMENSION.THE MINIMUM EXPOSED BARREL LENGTH IS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM COVER PLATE WIND VELOCITY PN THE EXPOSED SPRINKLER OF 30 MPH(48 KM/H). CEILING LONGER EXPOSED BARREL LENGTHS WILL HELP AVOID FREEXING OF THE WET PIPING WHERE HIGHER WIND VELOCITY IS EXPECTED. (PROTECTED AREA) 3 5/16'DIA. RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENT WET PIPE ✓t s-1 _c7,4=-11-__7 lr--H----u u g____a --1fi t=== a L s- r_zJ r -= 5 II I'7 (HEATED AREA) MINIMUM EXPOSED ' L BARREL S LENGTH DECKTITE FLASHING INSIDE FACE (SEE ABOVE) RASCO F / (RECOMMMENDED)ENDED) S //// rl 1 i i 1 w ....................... CLEARANCE HOLE INSULATED FREEZER, OR COOLER STRUCTURE - -- OR EXTERIOR FRAMING W///// _ DRY SPRINKLER IN COLD AREA (PROTECTED AREA) 051 FG02 Figure 2 4. *CAUTION* DO NOT INSTALL MODEL G5-56 DRY SPRINKLERS WITH STANDARD INLETS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION; THIS WILL DAMAGE THE SPRINKLER, THE FITTING, OR BOTH. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. A SHORT INLET ("PL")VERSION OF THE MODEL G5-56 DRY SPRINKLER IS AVAILABLE FOR USE IN EXISTING INSTALLATIONS WITH CPVC ADAPTER FITTINGS OR TEES HAVING AN INTERNAL OBSTRUCTION; THE SHORT INLET VERSION SHALL NOT BE USED ON DRY-PIPE SPRINKLER SYSTEMS. VERIFY SPRINKLER AND FITTING DIMENSIONS PRIOR TO INSTALLATION TO AVOID INTERFERENCE. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION j Tit, .0 ..iii FEMALE -rir Tit IFoFEMALE O PIPE / 1 PIPE •� / j THREAD THREAD CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE - WITH INTERNAL NO INTERNAL OBSTRUCTION OBSTRUCTION SHORTER _- LONGER INLET -- INLET A f MALE .111 MALE II PIPE PIPE THREAD vv. THREAD rir MODEL G5-56 STANDARD SHORT INLET ("PL") MODEL G5-56 DRY SPRINKLER DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 051 FG03 Figure 3 5. Maintenance Ordering Information The Model G5-56 Dry should be inspected and the sprin- Specify: kler system maintained in accordance with NFPA 25. Do 1. Sprinkler: Model G5-56 Dry not clean sprinklers with soap and water, ammonia or any 2. Threads: [1-inch NPT-standard][IS0 7/1 R1 -optional] other cleaning fluids. Replace any sprinkler that has been 3. Inlet Length: [Standard][Short ("PL")—for existing wet- painted (other than factory applied) or damaged in any pipe installations only] way. Concealed sprinklers cover plates can not be painted 4. Cover Plate Finish: [White][Chrome][Special Applica- in the field, after installation or have any other coating ap- tion—Specify] plied other than the factory finish. A stock of spare sprin- 5. Sprinkler/Cover Plate Temperature Rating: [Ordinary— klers should be maintained to allow quick replacement of 165°F sprinkler with 135°F cover plate][Intermediate— damaged or operated sprinklers. Prior to installation, sprin- 212°F sprinkler with 165°F cover plate] kler should be maintained in the original cartons and pack- 6. Nominal Sprinkler Length (face of fitting to face of aging to minimize the potential for damage to sprinklers ceiling - "A" Dimension from Fig. 1): [Specify length — that would cause improper operation or non-operation. Lengths available from 41/4 inches to 48 inches(108mm Engineering Specification to 1219mm) in'/4-inch (6.35mm) increments] Model G5-56 Dry Pendent Concealed Sprinkler Dry pendent sprinklers shall be dry pendent concealed sprinklers with a flat cover plate. Sprinklers shall be cU- Lus Listed as Quick Response for Light and Ordinary Hazard applications as well as FM Approved as Standard Response. Sprinklers shall be available in lengths from 41/4 inches (108mm) to 48 inches (1219mm) in 1/4-inch (6.35mm) increments based on face of fitting to finished ceiling distance. Sprinkler length shall be selected to pro- vide the Exposed Minimum Barrel Length based on the minimum design temperature in the protected area and the minimum temperature in the conditioned space where the barrel is located in accordance with the Manufactur- er's written installation instructions. Sprinklers shall have [1-inch NPT][ISO 7-1 R1] threaded inlet fittings with [stan- dard length inlets designed for use with wet- or dry-pipe sprinkler systems][short length inlets designed for use with wet-pipe sprinkler systems having pipe fittings with internal obstructions that prevent the insertion of standard length inlets]. Sprinklers shall have a PTFE coated beryllium nick- el Belleville spring washer inlet seal and brass alloy cap that prevent water entry from the sprinkler system piping into the sprinkler prior to actuation. Sprinklers shall have a fast-response fusible link that controls the movement of the inlet seal and cap through a mechanism consisting of link arms, a seat adapter, an orifice adapter, an inner tube, and a yoke. Sprinklers shall use a drop down deflector supported by tapered pins. Sprinklers shall have a galva- nized steel cup for threaded attachment of the flat cover plate assembly. Cover plate attachment shall provide up to'/cinch (13mm) of adjustment. Sprinklers shall be [Ordi- nary temperature classification, 165°F (74°C), with 135°F temperature rated cover plates][Intermediate temperature classification, 212°F, with 165°F temperature rated cover plates]. Cover plates shall be[solid][perforated]with facto- ry applied [White][Chrome][Special Application —Specify] finish. Dry pendent concealed sprinklers shall be Reliable Model G5-56 Dry(SIN RA5114). 6. MATERIAL SPECIFICATIONS m m mo` ff, 0 ITEM# DESCRIPTION MATERIAL '/' 1- 1 BODY,MACH. DZR BRASS • �IIIIIIIIII11111IIIIV�� 2 DEFLECTOR COPPERALLOY m 3 DEFL.SPLITTER BRASS ALLOY 4 DEFL. PIN STAINLESS STEEL 5 MEGA-INLET DZR BRASS —Ji' ; 6 LINK ASSY. NICKELIBERYLLIUMNICKEL 7 LEVER COPPER ALLOY ® �-1' '+�a' •4 8 OUTER TUBE GALVANIZED STEEL i ik I ,' 1 9 INNER TUBE BRASS ALLOY ii 10 FLIP DISK BRASS ALLOY 11 CAP BRASS ALLOY 12 WASHER PTFE COATED BERYLLIUM NICKEL Co 13 SET SCREW STAINLESS OR ALLOY STEEL 14 LOAD SCREW STAINLESS STEEL 15 BOTTOM CUP _ GALVANIZED STEEL 16 TOP CUP GALVANIZED STEEL 17 ADJ.SEAT ADAPTER BRASS ALLOY 0 j m 18 YOKE BRASS ALLOY 1NU 19 CLOSURE YOKE BRASS ALLOY / 20 ORIFICE ADAPTER BRASS ALLOY ® t` 11 O 1. �i�\�'%//Vii',,i_k ` 0(PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) 0 ��1;nil�-�In j31+ �— � � - m �t11100.n .,r_ ® S>_0,,- -_�o1 0 '�� --r.,-,"-------1,----1.,„;44 1 0 o © 051 FG04 0 ��,aullll�������lllli,,���� Figure 4 7. Reliable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100. Manufactured by Reliable Automatic Sprinkler Co.,Inc. Recycled ® (800)431-1588 Sales Offices Paper lid (800)848 6051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.09/16 P/N 9999970480