CON17-0002_Vail Valley Medical Center Phase I ERRC System Permit Submittals_072417_1501093440.pdf
VAIL VALLEY MEDICAL CENTER EMERGENCY RESPONDER RADIO COVERAGE SYSTEM PERMIT SUBMITTALS Submitted to VAIL FIRE DEPARTMENT 2399 N FRONTAGE RD W. VAIL, CO 81657 7/24/17 Submitted by: ICC WIRELESS SUBS!DIARY or INTERFACE COMMUNICATIONS 10 INVERNESS DRIVE EAST, SUITE 100, ENGLEWOOD, CO 80112 Vail Valley Medical Center Emergency Responder Radio Coverage System System Narrative SYSTEM NARRATIVE Overview The following is a design submittal for an Emergency Responder Radio Coverage Distributed Antenna System (DAS) at the Vail Valley Medical Center, 181 West Meadow Drive, Vail, CO 81657. The intent of the system is to enhance first responder communications within the building for Vail fire on the Colorado DTRS system, per Vail Fire Code, IFC 2015. The project is based upon an Axell Wireless bi-directional amplifier (BDA) and a Solid Technologies Express Distributed Antenna System (DAS) platform. The system has been design to meet and exceed the requirements of IFC 2015. Key points include: • RSSI of-95 dBm or better over 90% of the facility including areas below grade. Critical areas, such as the fire command center(s), the fire pump room(s), interior exit stairways, exit passageways, elevator lobbies, standpipe cabinets, sprinkler sectional valve locations, and other areas required by the fire code official, shall be provided with 99 percent floor area radio coverage. • 24 hour UPS with dedicated lock circuit for DAS components • NEMA 4 enclosures for DAS components Permitting ICC Wireless will coordinate all required Permitting. Design The design of the 800MHz Emergency Responder Radio Coverage DAS is based on a goal of achieving an RSSI level of -95 dBm. It includes a bi-directional amplifier (BDA) for the 800MHz Public Safety Band, head end and remote DAS electronics, indoor omni-directional antennas, plenum-rated 1/2" coaxial cable that will be installed from the remote hub to each antenna, and a YAGI Donor antenna that will be installed on the roof. The BDA, DAS head end, and UPS will be located in the IDF closet on Level 3 of the East Wing. Acceptance Testing Final Acceptance Testing will be done in accordance to with IFC 2015 guidelines. The Final Acceptance Documentation shall contain the results of coverage testing, after commissioning, on the Colorado DTRS 800 MHz Radio system. 1 Methodology Talk-back testing from a site to the Colorado DTRS 800 MHz Radio System shall use Vail Fire Department radio(s) and be witnessed by a representative of the Vail Fire Department. Per IFC 2015, each floor of the building shall be divided into a grid of 20 test areas. Measurements shall be taken in each of these areas with spectrum analyzer in order to identify which areas of the building are within compliance. A test location approximately in the center of each test area shall be selected for the test, with the radio enabled to verify two-way communications to and from the outside of the building through the Colorado DTRS 800 MHz Radio System. Once the test location has been selected, that location shall represent the entire test area. Failure in the selected test location shall be considered failure of that test area. The radio system signal level shall meet or exceed -95 dBm at 90% or more of the locations measured within each grid area. The areas to be measured include all common areas, garages, stairwells, elevators and corridors. The recorded measurements shall be the largest of the readings taken. Results The results shall be displayed in tabular form. For the facility, the number of pass measurements (meeting or exceeding -95 dBm) shall be divided by the total number of measurements taken to provide a metric of pass percentage. This value should be greater than 90%. In addition, floor plans with the measurements values overlaid on them shall be included. Included with this package: • Wiring Riser and Distribution Diagrams (Schematic Design, Antenna Layout, and Location of BDA and DAS Equipment • System Link Budget • Manufacturer Specification Sheets 2 Vail Valley Medical Center Emergency Responder Radio Coverage System System Design Vail Valley Medical Center - Phase Ic 181 W Meadow Drive, Vail CO 81657 4 r r� + p ,1 10 . - ' T 7 ' i`wwii [ 74-1Ea _.:.._R-E4.11f. _ e..e.p ee 111 el ozn MI 1111 x„.„_ *h. ren ar �mmY °e --Iz .e, H 1 _ H j'e I-I — I..I 1. „„,„.74.7.4.hioz 41:,,. ,,,1 \r4... Min LI. Ip:ti°,a,'. Tx 1 �... Publlsafety,UHF.Analog,2Sectors 4 4 ° g Y ' Y 1:1 A"*"' Public Safety/800 MHz-SMR•P25/2 Sectors I O �.. I 1 1 I ! i I I I 1 I I I I I 1 I 1 I I 1 ,, 1 o-- - mss-... I ,,,_r - - ] _ t. . 1 ,_._,0-- _ _.. _. n , 11 -1. , ,_ ___ i „, ._ ..E, n o- ■ 1 r REAG10O00A I I. II -1 . 1 .. 0 C e,°_ie n1 111■ _n Is m 81lffI AIOAIB 6x¢ilNGs., pp F➢RI®4YM.BlpF$flE LADDER TOlc .Gl , « SfA600L u�iH LI ra<rxvN a • `^, IQ. 4'UVYISi '1 Ii I t ISI . �__� __ - j .. \.,-. ' ice. --_ mow. - - mss. •-- _.._.._.._.._ — . A ,.rte J 1i w ---%Ad 014.4 r---- . • uewcvAI. a `'�: _ ■ mil —- ..-moo i �-r�a :� a. �c.�' ice- LV Arli A"''-----------j_____________1_ _,,t•-•-"'--- 1 4,.. A B -LW,M. COLOR KEY -- 17.Ap1,(NISTRATION .CIRC•PAT?STAFF Enai„+om co ea„z CIRC-PM 'CIRC-VERMAL (//,- / /- ■MATERIALS MANAGEMENT \\, C PARKING \ lL ` 11 a M I -j n� _ lIMfrlllif1 1 I • itaiRails7l I I I I l I l Il l l fi a . �. j--�-� � ` J 1 I IIrlII tl �I_� , f , • � IIII [...°i L— d — �7 — ' _ 1 �✓ -r - H H - D� M H —L E!C :E71,1E1 H N,- 7 E. 11 H 1 r - - H H • D� -E M _ .23 CI. M. Q Q . 1 ! 1 i'...■ VAILVALLEYMEDICALCENTER- .....-1.- 1 ,M^q DAMS Vail I�nik EAST WING-LEVEL 1 EAST WING ADDITION& a, • ■■■'Arc-Vit rs Medica! er *s RENOVATION aa',5, s. COLOR KEY - •BUILDING SUPPORT n CIRC-PATI STAFF E r:Era r„2 ❑cr+c•PVB ❑CIRC VERTICAL ▪Lam f PUBLIC r, ■MEP ❑PALMING El SHELL Azt# • in VOLUNTEERS \ as. '!N swami= is Ell . / , .., \,\ III I h ..., I J 9 9 9 ® 9 -� SI 1 I SIJ 0 0r, !i ® GI Al - - -1_il ---a � _ I II b i DPI TO-L2 IN - _ ma _ r • c i! Emma IliI iimini 11 El yid fff L 1/El ISM 1, .r L - II I'_., . • a. . I 1. ill• LI 1,-.-r-i—n---- 1 J .".•"DAVIS 1� I VAIL VALLEY MEDICAL CENTER• �lli'�Yiil1ry EAST WING LEVEL 2 EAST WING ADDITION& L.°2 MNIZTHI era g2diraI RENOVATION ,` .iCC1 COLOR KEY I s* �._.�_.__�^-- ADMINISTRATION IMAGING Jr .,y AMBULANCE DROP OFF [1 MEP tea iaw;,"ii•A •BUILDING SUPPORT PHARMACY — — _ _ _ . 'A CIRC-PAT!STAFF SHELL / `s CIRC•PUB _ SC � s Wt CIRC•VERTICAL - '"'e • ■ENERDENCY ■EMERGENCY-PMBUTANLE ,,� • F_J -_ - c`s _ Y a _ _, 0 -F A - 1 Ft, . R _ [1 . 9 .i.1.• 5 9 a` ; . � : 1: L1 I FT — -i -:,.. I .. 1,,I Li I �� _L. 1 • I rA.1 i I ' r: . r, r lam; L I ,-- 11 IP. + e II VAIL VALLEY MEDICAL CENTER- J >.�DAV!5 Vail Valley EAST WING LEVEL 3 r n;RzrEliScr5 MedimiCeltt� EAST WING ADDITION- 8 Sr " RENOVATION /•.... .__14'n'T•Lt.51- "2,FanA'' COLOR KEY i 'Seile..-2: :-.4 Ace.704.411,\ •4.1...... .. . 1 AMEuLANCE DISTRICT CIRO•PAT/STAFF AV' '1,..4744, . CRC-VERTICAL 44:\\-,. rt14;:::': ,e.,• .t ir- . p:, Aa, .,-:,,, ..„ .„;5.4,,, •, .4*t n MEP ''•;:i,,,•Er •71' • PuBLIC CIRCULATION • • 5I-TELL it •.,..,,'/ -...N.:c,. r ,, . I— L I 11A .. ' • 11—J .3 - 2_, -.—..—.. =,... 7 ... . 1011111 — I i-1--7 Will , l'• 1 ' NUL -.'-"' •'' k'.11cie . !' "'" r I 1111 ' liM III . i i . _L- , MI ii MIN 111111 - -- - - _ •[- k, . 1 EliffillliffiffiETMIIMMITTIMETTITTT ff ] ._Ii • . AI- • 1 . . ..= • ._ ... .__..) 4--.• . .... ffl ': -- l'H ----7----..-"' -1-'- : ' r I Connect to UHF Repeaters in Radio SIC 42 N - __ ,...,i,:,:_.,- ,._. Al. ..."'''i TTT77.. - —1 —F- 1 .,,i FF N... A 41 M ;A .) • m .$.N 4- ..... i _._ . Donor antenna -. installed on parapet- _. pointing towards Qwest Tower imi a =VII Vail Valley Medical Center Emergency Responder Radio Coverage System System Link Budget Link Budget Report Project name: Vail Valley Medical Center PS-Phase I Design company: ICC Wireless LLC Project creation date: 7/19/2017 Designer: Stephen Olsen DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb. of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A ID Model Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANTO-L1 ANTO-L1(dBd) PEAR S5491i Pigtail - - - 1.35 -38.53 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -97.00 - - - - - - - MS signal range - - - - 24.73 - --- C10 AL4RPV-50 215.50 - - -5.28 -39.88 - - - - - SPT4-L1 S-3-TCPUSE-H-N - - - -5.00 -34.59 - ---- C7 AL4RPV-50 34.07 - - -0.92 -29.59 - - - - - - SPT6-L2 S-2-TCPUSE-H-N - - - -3.10 -28.68 --- C19 AL4RPV-50 52.11 - - -1.35 -25.58 - ---- SPT4-L3 CA-14N - - - -3.20 -24.22 ---- JMP2 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 ---- JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - ---- RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - --- C17 LDF4-50A 126.51 - - -2.74 -41.74 - ----- Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 ---- (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 1/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANTO-L2 ANTO-L2 (dBd) PEAR S5491i Pigtail - - - 1.35 -33.14 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -91.60 - - - - - - - MS signal range - - - - 46.01 - - - - - - - C32 AL4RPV-50 84.76 - - -2.14 -34.49 - - - - - - SPT3-L2 S-2-TCPUSE-H-N - - - -3.10 -32.35 - - - - - - JMP13 RG-142 NM-NF-3' Jumper - - -0.57 -29.25 - - - - - - SPT5-L2 S-2-TCPUSE-H-N - - - -3.10 -28.68 - - - - - - C20 AL4RPV-50 52.15 - - -1.35 -25.58 - - - - - - SPT5-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP8 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 2/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A I Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANTI-L1 ANTI-L1 (dBd) PEAR S5491i Pigtail - - - 1.35 -39.26 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -97.73 - - - - - - - MS signal range - - - - 22.73 - - - - - - - C16 AL4RPV-50 246.90 - - -6.04 -40.61 - - - - - - SPT1-L1 S-3-TCPUSE-H-N - - - -5.00 -34.57 - - - - - - C11 AL4RPV-50 33.03 - - -0.89 -29.57 - - - - - - SPT5-L2 S-2-TCPUSE-H-N - - - -3.10 -28.68 - - - - - - C20 AL4RPV-50 52.15 - - -1.35 -25.58 - - - - - - SPT5-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP8 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 3/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT1-L3 ANT1-L3 (dBd) PEAR S5491i Pigtail - - - 1.35 -27.47 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -85.94 - - - - - - - MS signal range - - - - 88.34 - - - - - - - Cl AL4RPV-50 34.41 - - -0.93 -28.82 - - - - - - SPT7-L3 S-2-TCPUSE-H-N - - - -3.10 -27.89 - - - - - - JMP9 RG-142 NM-NF-3' Jumper - - -0.57 -24.79 - - - - - - SPT4-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP2 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 4/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT1-L4 ANTI-L4(dBd) PEAR S5491i Pigtail - - - 1.35 -41.64 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -100.11 - - - - - - - MS signal range - - - - 17.27 - - - - - - - C5 AL4RPV-50 47.21 - - -1.24 -42.99 - - - - - - SPTO-L4 S-3-TCPUSE-H-N - - - -5.00 -41.76 - - - - - - C18 AL4RPV-50 81.02 - - -2.05 -36.76 - - - - - - SPT8-L3 S-2-TCPUSE-H-N - - - -3.10 -34.71 - - - - - - C2 AL4RPV-50 150.42 - - -3.72 -31.61 - - - - - - SPT7-L3 S-2-TCPUSE-H-N - - - -3.10 -27.89 - - - - - - JMP9 RG-142 NM-NF-3' Jumper - - -0.57 -24.79 - - - - - - SPT4-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP2 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 5/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A I Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT2-L1 ANT2-L1 (dBd) PEAR 55491i Pigtail - - - 1.35 -35.43 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -93.90 - - - - - - - MS signal range - - - - 35.33 - - - - - - - C15 AL4RPV-50 87.67 - - -2.21 -36.78 - - - - - - SPT1-L1 S-3-TCPUSE-H-N - - - -5.00 -34.57 - - - - - - C11 AL4RPV-50 33.03 - - -0.89 -29.57 - - - - - - SPT5-L2 S-2-TCPUSE-H-N - - - -3.10 -28.68 - - - - - - C20 AL4RPV-50 52.15 - - -1.35 -25.58 - - - - - - SPT5-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP8 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 6/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT2-L2 ANT2-L2 (dBd) PEAR S5491i Pigtail - - - 1.35 -35.77 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -94.24 - - - - - - - MS signal range - - - - 33.97 - - - - - - - C23 AL4RPV-50 194.35 - - -4.77 -37.12 - - - - - - SPT4-L2 S-2-TCPUSE-H-N - - - -3.10 -32.35 - - - - - - JMP12 RG-142 NM-NF-3' Jumper - - -0.57 -29.25 - - - - - - SPT6-L2 S-2-TCPUSE-H-N - - - -3.10 -28.68 - - - - - - C19 AL4RPV-50 52.11 - - -1.35 -25.58 - - - - - - SPT4-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP2 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 7/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT2-L3 ANT2-L3 (dBd) PEAR S5491i Pigtail - - - 1.35 -33.93 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -92.40 - - - - - - - MS signal range - - - - 41.99 - - - - - - - JMP11 RG-142 NM-NF-3' Jumper - - -0.57 -35.28 - - - - - - SPT8-L3 S-2-TCPUSE-H-N - - - -3.10 -34.71 - - - - - - C2 AL4RPV-50 150.42 - - -3.72 -31.61 - - - - - - SPT7-L3 S-2-TCPUSE-H-N - - - -3.10 -27.89 - - - - - - JMP9 RG-142 NM-NF-3' Jumper - - -0.57 -24.79 - - - - - - SPT4-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP2 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- I 896MHz) Created on 7/24/2017 Page 8/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Model Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT2-L4 ANT2-L4(dBd) PEAR S5491i Pigtail - - - 1.35 -43.71 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -102.18 - - - - - - - MS signal range - - - - 13.62 - - - - - - - C6 AL4RPV-50 132.99 - - -3.30 -45.06 - - - - - - SPTO-L4 S-3-TCPUSE-H-N - - - -5.00 -41.76 - - - - - - C18 AL4RPV-50 81.02 - - -2.05 -36.76 - - - - - - SPT8-L3 S-2-TCPUSE-H-N - - - -3.10 -34.71 - - - - - - C2 AL4RPV-50 150.42 - - -3.72 -31.61 - - - - - - SPT7-L3 S-2-TCPUSE-H-N - - - -3.10 -27.89 - - - - - - JMP9 RG-142 NM-NF-3' Jumper - - -0.57 -24.79 - - - - - - SPT4-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP2 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 9/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT3-L2 ANT3-L2 (dBd) PEAR S5491i Pigtail - - - 1.35 -33.56 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -92.03 - - - - - - - MS signal range - - - - 43.80 - - - - - - - C24 AL4RPV-50 102.60 - - -2.57 -34.91 - - - - - - SPT3-L2 S-2-TCPUSE-H-N - - - -3.10 -32.35 - - - - - - JMP13 RG-142 NM-NF-3' Jumper - - -0.57 -29.25 - - - - - - SPT5-L2 S-2-TCPUSE-H-N - - - -3.10 -28.68 - - - - - - C20 AL4RPV-50 52.15 - - -1.35 -25.58 - - - - - - SPT5-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP8 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 10/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT3-L3 ANT3-L3 (dBd) PEAR S5491i Pigtail - - - 1.35 -29.46 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -87.93 - - - - - - - MS signal range - - - - 70.25 - - - - - - - C3 AL4RPV-50 117.17 - - -2.92 -30.81 - - - - - - SPT6-L3 S-2-TCPUSE-H-N - - - -3.10 -27.89 - - - - - - JMP10 RG-142 NM-NF-3' Jumper - - -0.57 -24.79 - - - - - - SPT5-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP8 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 11/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Model Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT3-L4 ANT3-L4(dBd) PEAR S5491i Pigtail - - - 1.35 -44.20 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -102.67 - - - - - - - MS signal range - - - - 12.88 - - - - - - - C8 AL4RPV-50 153.34 - - -3.79 -45.55 - - - - - - SPTO-L4 S-3-TCPUSE-H-N - - - -5.00 -41.76 - - - - - - C18 AL4RPV-50 81.02 - - -2.05 -36.76 - - - - - - SPT8-L3 S-2-TCPUSE-H-N - - - -3.10 -34.71 - - - - - - C2 AL4RPV-50 150.42 - - -3.72 -31.61 - - - - - - SPT7-L3 S-2-TCPUSE-H-N - - - -3.10 -27.89 - - - - - - JMP9 RG-142 NM-NF-3' Jumper - - -0.57 -24.79 - - - - - - SPT4-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP2 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 12/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT4-L2 ANT4-L2 (dBd) PEAR S5491i Pigtail - - - 1.35 -33.61 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -92.08 - - - - - - - MS signal range - - - - 43.58 - - - - - - - C25 AL4RPV-50 104.46 - - -2.61 -34.96 - - - - - - SPT4-L2 S-2-TCPUSE-H-N - - - -3.10 -32.35 - - - - - - JMP12 RG-142 NM-NF-3' Jumper - - -0.57 -29.25 - - - - - - SPT6-L2 S-2-TCPUSE-H-N - - - -3.10 -28.68 - - - - - - C19 AL4RPV-50 52.11 - - -1.35 -25.58 - - - - - - SPT4-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP2 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 13/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT4-L3 ANT4-L3 (dBd) PEAR S5491i Pigtail - - - 1.35 -30.64 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -89.11 - - - - - - - MS signal range - - - - 61.35 - - - - - - - C4 AL4RPV-50 166.06 - - -4.09 -31.99 - - - - - - SPT6-L3 S-2-TCPUSE-H-N - - - -3.10 -27.89 - - - - - - JMP10 RG-142 NM-NF-3' Jumper - - -0.57 -24.79 - - - - - - SPT5-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP8 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 14/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A I Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANTI-L1 ANTI-L1 (dBd) PEAR S5491i Pigtail - - - 1.35 -37.39 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -95.86 - - - - - - - MS signal range - - - - 28.19 - - - - - - - C12 AL4RPV-50 168.23 - - -4.15 -38.74 - - - - - - SPT4-L1 S-3-TCPUSE-H-N - - - -5.00 -34.59 - - - - - - C7 AL4RPV-50 34.07 - - -0.92 -29.59 - - - - - - SPT6-L2 S-2-TCPUSE-H-N - - - -3.10 -28.68 - - - - - - C19 AL4RPV-50 52.11 - - -1.35 -25.58 - - - - - - SPT4-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP2 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 15/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANTS-LL ALL(dBd) PEAR 55491i Pigtail - - - 1.35 -34.69 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -93.16 - - - - - - - MS signal range - - - - 38.45 - - - - - - - CO AL4RPV-50 57.09 - - -1.47 -36.04 - - - - - - SPT1-L1 S-3-TCPUSE-H-N - - - -5.00 -34.57 - - - - - - C11 AL4RPV-50 33.03 - - -0.89 -29.57 - - - - - - SPT5-L2 S-2-TCPUSE-H-N - - - -3.10 -28.68 - - - - - - C20 AL4RPV-50 52.15 - - -1.35 -25.58 - - - - - - SPT5-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP8 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 16/18 DAS link budget report Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Sector N/A\n Nb.of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Length Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (feet) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) ANT26-LL AN-LL(dBd) PEAR S5491i Pigtail - - - 1.35 -36.97 - - - - - - -N-Type- Below Ceiling MS RSSI [dBm] - - - - -95.44 - - - - - - - MS signal range - - - - 29.57 - - - - - - - C9 AL4RPV-50 150.90 - - -3.73 -38.32 - - - - - - SPT4-L1 S-3-TCPUSE-H-N - - - -5.00 -34.59 - - - - - - C7 AL4RPV-50 34.07 - - -0.92 -29.59 - - - - - - SPT6-L2 S-2-TCPUSE-H-N - - - -3.10 -28.68 - - - - - - C19 AL4RPV-50 52.11 - - -1.35 -25.58 - - - - - - SPT4-L3 CA-14N - - - -3.20 -24.22 - - - - - - JMP2 RG-142 NM-NF-3' Jumper - - -0.57 -21.02 - - - - - - SPT3-L3 S-2-TCPUSE-H-N - - - -3.10 -20.45 - - - - - - JMP7 RG-142 NM-NF-3' Jumper - - -0.57 -17.35 - - - - - - RPTO-L3 FR-PS78-P33A92 - - - 24.96 -16.78 - - - - - - C17 LDF4-50A 126.51 - - -2.74 -41.74 - - - - - - Donor(ANTO-L4) CSI-AY/746-896/11 - - - 11.00 -39.00 - - - - - - (11dBi Yagi 746- 896MHz) Created on 7/24/2017 Page 17/18 System link budget Public Safety\n800 Public Safety\n800 MHz-SMR\nP25\n MHz-SMR\nP25\n Downlink Model Sector N/A\n Nb. of Sector N/A\n Nb.of ch.:6\n NPSPAC\nN/A ch.:6\n NPSPAC\nN/A Gain/loss Gain/loss Gain/loss Gain/loss Gain/loss (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) (dB) (dBm) BTS2 TX comb. losses - 0.00 25.22 - - - - - - - - Power out - - 25.22 - - - - - - - - TX power/ch - - 25.22 - - - - - - - - OffAirO Isotropic offset - - - 2.15 -39.00 - - - - - OffAir-Donor Gain CSI-AY/746-896/11(11dBi - - 8.85 -41.15 - - - - - (dBd) Yagi 746-896MHz) Measured RSSI - - - - -50.00 - ----- Power out - - - - -39.00 - ---- System legend Public Safety\n800 MHz-SMR\nP25\n Sector N/A\n Nb. of ch.:6\n NPSPAC\nN/A/Public Safety/P25/800 MHz-SMR Band/ NPSPAC Block/Nb. of channels: 6/ Nb. of sources: 1 Public Safety\n800 MHz-SMR\nP25\n Sector N/A\n Nb. of ch.:6\n NPSPAC\nN/A/Public Safety/P25/800 MHz-SMR Band/ NPSPAC Block/Nb. of channels: 6/ Nb. of sources: 1 Calculation legend Public Safety\n800 MHz-SMR\nP25\n Sector N/A\n Nb. of ch.:6\n NPSPAC\nN/A/MS RSSI [dBm] (at 98.43 [feet])/ MS signal range [feet] (for-85.00 [dBm]) Public Safety\n800 MHz-SMR\nP25\n Sector N/A\n Nb. of ch.:6\n NPSPAC\nN/A/MS RSSI [dBm] (at 98.43 [feet])/ MS signal range [feet] (for-85.00 [dBm]) Created on 7/24/2017 Page 18/18 VAIL VALLEY MEDICAL CENTER EMERGENCY RESPONDER RADIO COVERAGE SYSTEM PRODUCT DATA SUBMITTALS Submitted to VAIL FIRE DEPARTMENT 2399 N FRONTAGE RD W. VAIL, COLORADO 81657 7/24/17 Submitted by: ICC WIRELESS ASUBSIDIARY OF INTERFACE co,w, urJ]cArror.Js 10 Inverness Drive East, Suite 100 Englewood, CO 80112 Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TABLE OF CONTENTS ITEM TAB SOLID TECHNOLOGIES EXPRESS PUBLIC SAFETY DISTRIBUTED ANTENNA SYSTEM 1 AXELL WIRELESS BI-DIRECTIONAL AMPLIFIER 2 GALTRONICS OMNI-DIRECTIONAL INDOOR ANTENNAS(PUBLIC SAFETY) 3 ANDREW%2'COAXIAL CABLE 4 ANDREW N-MALE CONNECTOR 5 ANDREW SPLITTERS AND DIRECTIONAL COUPLERS(PUBLIC SAFETY) 6 EMR DUPLEXER 7 MICROLAB HYBRID COUPLER „ 8 WESTELL YAGI ANTENNA ,,, 9 ROHN ROOF MOUNT 10 POLYPHASER LIGHTNING PROTECTOR 11 MINUTEMAN UPS 12 HOFFMAN NEMA ENCLSOURE 13 Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 1 SOLID TECHNOLOGIES EXPRESS PUBLIC SAFETY DISTRIBUTED ANTENNA SYSTEM EXPRESS 150/450/700/800 MHz Public Safety and Land Mobile Radio S O L i D Product Specification EXPRESS Public Safety Specifications and Parts List rook' �p5 ®5g 'MIIllllgl 0 Illlllll 1, .�; 5 _, ,.,, 111 11111 VIII :fie,44 ,E , 1011... 111111 11111 of ® . A robust Distributed Antenna System • Lower Equipment Costs— high efficiency providing highly reliable, code-compliant with fewer components. public safety radio coverage in buildings • Lower Operations Costs— rugged design and public venues. and convection cooling means no moving parts. Supports all current public safety bands • Fiber Efficiency— typically one fiber needed necessary for compliance with national to connect a building. and international codes and ordinances. • Flexible Deployment — small footprint, Web-based management interface for NFPA 72 Compliant/NEMA 4 Certified, onsite or remote setup, monitoring, and wall or rack mounted remotes. maintenance. • Easy Setup— auto-configuration simplifies commissioning. Version 1.1 —April 2015 ©2015 SOLID.All Rights Reserved.Confidential&Proprietary. www.solid.com EXPRESS DAS Public Safety — Product Specification Specifications RF Parameters RF and Optical Information 700PS 800PS VHF UHF RF Output Power,downlink(dBm) +27±0.5 +27±0.5 +24±0.5 +24±0.5 RF Output Power, uplink(dBm) 0±0.5 0±0.5 -4±0.5 -4±0.5 Downlink Gain (dB) 22-47 22-47 14-39 14-39 Uplink Gain(dB) 25-50 25-50 25-45 25-45 TX Frequency Range(MHz) 758-775 851 -869 136- 174 385-512 RX Frequency Range(MHz) 788-805 806-824 136- 174 385-512 Noise Figure 8dB max 8dB max 7dB max 7dB max Spurious (dBm) <-13 Optical Link AGC Above 10dB VSWR BIU: 1.5 /MRU 1.6 Passband ripple 4dBp-p per Band Optic Link Loss Max 5dBo Optic wavelength 1310nm/1550nm with WDM Uplink Input Power -50dBm Gain Control Range 25dB/step 1dB Standards and Certifications NFPA 72 Code Compliant National Fire Alarm Code. NEMA 4 Meets NEMA 4 enclosure standards to withstand rain, sleet, snow, dust, dirt, splashing water, hose-directed water, and corrosion. _ UL(North America) UL 60950-1, 2nd Edition❑CSA C22.2 No. 60950-1-07, 2nd Edition, CSA C22.2 No. 60950-1-03, 1st Edition FCC(North America) FCC Part24 Subpart D and Part90 Subpart I FCC Part22 Subpart H and Part 27 Subpart C FCC Part24 Subpart E and Part 27 Subpart C IC(Canada) RSS-131 (ISSUE 2), ICES-003 Emissions (North America) FCC Part15 Subpart B, Class A. VHF: F1D, F3E UHF: F1D, F1 E, F3E MTBF (Telecordia SR-332 Issue) Failure Rate= MRU MTBF=24.5 Years; BIU MTBF = 8.3 Years Version 1.1 —April 2015 ©2015 SOLiD.All Rights Reserved.Confidential&Proprietary. www.solid.com EXPRESS DAS Public Safety — Product Specification Mechanical Information MRU 700/800 AOR 150/450 AC Power Normal Range: 120VAC 50/60Hz Operating range: 108-132VAC, 50/60Hz DC Power Normal: -48 VDC. Operating range: -42 to-56V DC RF Output Connector Type N Female SMA Female Tx/Rx Output Configuration 1 port,Tx/Rx 700/800 2 ports, 1 Tx 150/450, 1 Rx 150/450 Dimensions 7.9"W x 11.8" H x 5.5" D 19"W x 6.96" H x 10.16" D 200 x 300 x 138.5 mm 482.6 x 177 x 258 mm Cabinet Type Sealed Enclosure Locking Enclosure with key Operating Temperature 14 to 122°F(-10 to+50°C) Operating Humidity 5%to 90% Non-condensing Weight 15.6 lbs(7.1 kg) 24.25 lbs(11 kg) Power consumption 50W 93W 700 and 800 Public Safety bands are supported in the EXPRESS Main Remote Unit(MRU). VHF and UHF are supported in the optional Add-On Remote (AOR). I FIBER ri ..„, I InPSlAFETaI�CY DAS 700/800 Tx/Rx 11111 1- 150/450 Rx 150/450 Tx X N N POWER O v U N N mi t'MY DAS Version 1.1 —April 2015 ©2015 SOLiD.All Rights Reserved.Confidential&Proprietary. www.solid.com EXPRESS DAS Public Safety — Product Specification Parts List Product Description Part Number BIU(Base Station Interface Unit)Signal Source Inputs BIU -SISO(Incl. DC/DC PS, MCPU Card, MCDU Card, Blanks) SC BIU SISO (Power supply not included) — — DMS Supporting Bracket SC_DMS_BRK Blank Input Module for the SC_BIU SC_MCDU_B EXPRESS BIU CPU SC_MCPU 700MHz PS&800MHz PS Input Module for the SC_BIU SC_MDBU_700_800 Blank Input Module for the SC_BIU SC_MDBU_B Power Supply for the SC_BIU SC_MPSU O xpansion Optical Distribution Unit Chassis SC_ODU_C Blank Optical Module for the ODU SC_ODU_B/SC_OEU_B 4 Port Optical Module SCODU OM4/ SC OEU OM 4 OEU Chassis. NOTE: Input Power-48VDC. Power supply not included. SC OEU C MRU,ARU, and VHF/UHF Add-on Remote 700 MHz PS&800 MHz PS Main Remote Unit-AC Power- NEMA Enclosure MRU AC 700 800 N 700 MHz PS&800 MHz PS Main Remote Unit-DC Power- NEMA Enclosure MRU DC 700 800 N 150MHz VHF&450MHz UHF Amplifier Module with AC Add-on Cabinet-NEMA SC_AC_150_450 150MHz VHF&450MHz UHF Amplifier Module with DC Add-on Cabinet-NEMA SC_DC_150_450 AC Power Supply Unit for MRU/ARU SC_PUS_AC 19" Rack MRU/ARU Chassis (4U Rack Space Requirement) SC_RM19 Vertical Rack Mount MRU/ARU (9U Rack Space Requirement) SC_RU_BRK 1111 DAS Management System for EXPRESS DMS_600 SOLiD 617 North Mary Avenue Sunnyvale, CA 94085 PHONE: 888.409.9997TL SOLID EMAIL: sales@solid.com 7� 1S09001 I S014001 WEB: www.solid.com H,VR4.O/R4.0 CERTIFIED Version 1.1 —April 2015 ©2015 SOLiD.All Rights Reserved.Confidential&Proprietary. www.solid.com Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 2 AXELL WIRELESS BI-DIRECTIONAL AMPLIFIER Product Specification Sheet axe I I ) WIRELESS BSR 3308 PS NFPA SMR 800 MHz RF Signal Booster, medium power Key features: • Band selective mini booster for SMR, ESMR and public safety networks • NFPA 72-2010, chapter 24 and IFC 510.1 compliant • IF-SAW filtering—high out-of-band rejection • Indoor coverage up to 100,000 square feet • Features Axell Wireless' SmartALCTM technology,to prevent oscillation • Switchable bandwidth option —User-selectable and tuneable across the 800 MHz band —Accommodates all re-banding phases without changing hardware • Web Based management, SNMP traps The BSR 3308 PS NFPA is available SmartALC power control characteristics of the BSR 3308 PS with a switchable bandwidth algorithm. SmartALC prevents NFPA careful component selection feature. With this feature, the unit oscillations, reduces the amount and robust design result in high is configured with three possible of isolation required by the system system reliability. frequency blocks that the and optimizes the system to operator can specify. One of the minimize noise rise at the donor This Axell product meets the rigid three blocks is selected by the site. SmartALC allows the installer requirements as defined by the user and tuned to the desired to quickly set up the unit, yet still NFPA and International Fire Code frequency during set up. This achieve the design goals specified developmental organizations. The permits the user to select the by the system engineer. amplifier is painted a Fire Life optimum pass band for each of Safety Red, meets NEMA4 the re-banding phases without the The BSR 3308 PS NFPA features compliance for hose down, and need to change any hardware. The two color front panel LEDs that provides all Alarming outputs as standard configurations provide ongoing status and alarm defined by NFPA 2010, Chapter 24 accommodate most of the pass indication. In addition, the DL LED including system and antenna band requirements for public can be used during setup as a failures. safety, ESMR and SMR networks. received signal strength level indicator to help align the donor The BSR 3308 PS NFPA includes antenna for optimal performance. Axell Wireless' proprietary The efficient thermal ©Axell Wireless I www.axellwireless.com I info@axellwireless.com I Version:3.2 I E&O.E.All specifications are subject to change without prior notice. 1 _ r The BSR 3308 PS NFPA signal booster is cost-effective for ter— medium sized buildings for coverage of 100,000 ft -Thersifiid,_ 1 It can be also coverage for outdoor coverage or as a feeder =r' __ to and also powerful enough to drive a passive Distributed Antenna System (DAS). ' 1111 Technical specifications PARAMETERS DOWNLINK UPLINK Electrical Frequency Rangel 851–869 MHz 806–824 MHz Pass band Gain 85 dB 85 dB Pass band Ripple ±1.5 dB ±1.5 dB Gain Attenuation Range 0 to 31 dB(in 1 dB steps) 0 to 31 dB(in 1 dB steps) Composite Output Power(per carrier) +33 dBm +24 dBm Noise Figure @ Maximum Gain (typical) 5.0 dB 5.0 dB Propagation Delay <5µsec <5 µsec ( )3 selectable and tuneable sub-bands are standard General Power Supply 220/110 VAC or 48VDC Power Consumption 120 W Total RF Input Power(no damage) +10 dBm RF Connector N-type, Female VSWR 1.7:1 Compliance FCC Environmental Operating Temperature -20 to 50°C(-4 to 122°F) Storage Temperature -30 to 80°C(-22 to 176° F) Humidity 10%-90%Condensed Dimensions LxWxH 13.78"x 18.11"x 5.7" (350 mm x 460 mm x 145 mm) Weight 28.8 lb(13 kg) Weatherproof IP-65, NEMA-4 Ordering Information IDENTIFICATION DESCRIPTION PART NUMBER BSR 3308 PS NFPA BSR 3308 SMR 800,33dBm 18/10/3 MHz NFPA BSR 3308-PS-18-10-3-NFPA BSR 3308 PS NFPA BSR 3308 SMR 800,33dBm 18/10/3 MHz NFPA 48VDC BSR 3308-PS-18-10-3- NFPA-DC About Axell Wireless Axell Wireless is one of the top global providers of wireless coverage solutions and the market leader in the provision of solutions for the public safety market worldwide. Our equipment has been deployed in some of the most technologically challenging environments in the world, providing coverage for tunnels, metros, buildings, stadiums and transportation systems all over the world. With its headquarters in the UK, Axell Wireless has been operating for over 40 years and has an international footprint. A proven track record combined with a reputation for providing innovative and high-quality products has made Axell Wireless a truly global player in the wireless coverage industry. ©Axel)Wireless I www.axellwireless.com I info@axellwireless.com I Version:3.2 I E&O.E.All specifications are subject to change without prior notice. Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 3 GALTRONICS OMNI-DIRECTIONAL INDOOR ANTENNA (PUBLIC SAFETY) Kip G IR I_,T R O Ill I CS 698-6000 Mhz,Omni Directional,In-Building Antenna A BnYLIN TECHNOLOGIES COMPANY Mounting Options This antenna can be mounted using any of the following mounting brackets.Optional mounting brackets need to be ordered as a separate line item.See Ordering Options for details(see page 1). Below Ceiling Installation (Standard) Fasteners for below suspended ceiling mounting included with antenna.Maximum ceiling thickness 1.18"(30mm). Drill a hole with a 1.18"(30mm)diameter into suspended - ceiling and secure the antenna with supplied plastic nut. OR Optionally the antenna can be installed below a suspended ceiling by using the provided M4 Threaded rod (x3) and M4 nuts. Included with antenna Optional Through Ceiling Mounting Bracket Through ceiling mounting conceals the antenna with only the nose protruding through the ceiling.The base plate is hidden above the false ceiling which results in a 40% 4e3Y° reduction of the visibile antenna footprint. P/N:62-17-09 Optional Above Ceiling Mounting Bracket The antenna can be installed above a suspended ceiling - by using the optional above ceiling mounting bracket. P/N:62-40-09 IMm1 Ordering&Antenna Options Part Number Connector Description Mounting Type i c 02121304-05491U N-Type (F) PEARTM S5491i Below Ceiling 02121304-0511= N-Type (F) PEARTM S5491 i with pre-installed Through Ceiling Mount o 02125304-05491U 4.1-9.5 DIN (F) PEARTM S5491i Below Ceiling 02125304-05491T I 4.1-9.5 DIN (F) PEARTM S5491i with pre-installed Through Ceiling Mount 02130304-05491U 4.3-10 DIN (F) PEARTM S5491i Below Ceiling 02130304-05491T 4.3-10 DIN (F) PEARTM 55491i with pre-installed Through Ceiling Mount o 62-40-09 Above Ceiling Mounting Bracket 62-17-09 Through Ceiling Mounting Bracket T, 27-272-09 External Ground Plane (60x60 cm) f Copyright©2015-Galtronics Corporation Ltd. Proprietary Information.AH rights reserved.Galtronics reserves the right to modify or amend any antenna or specification without prior notice. www.galtronics.com «i.j�) GA LT R O In I CS 380-6000 Mhz,Omni Directional,In-Building Antenna A BnYLIN TECHNOLOGIES COMPANY PEARTM S5491i Pigtail ti5 Broadband In-Building Antenna [380-6000 MHz] 0. ❑� Description: k'' S Ceiling mount omni directional antenna for illik.,1 , • 0 o=� in-building applications such as DAS.The `c antenna is vertically polarized and operates at 380-6000 MHz supporting also public safety frequencies (TETRA). Electrical Specifications Frequency Band[MHz] 380-520 I '98-790 I 790 96 1695-2200 2300-27011I 2700-6000 Input Connector Type N-Type or 4.3-10 DIN or 4.1-9.5 DIN Connector(F)with cable (12"/30 cm length) Polarization Vertical Antenna Structure Port 1 Impedance 50 0 VSWR/Return Loss <3:1/6.0dB <2:1/9.5dB <2:1/9.5dB < 1.8:1/10.9dB < 1.8:1/10.9dB <2.2:1/8.5dB VSWR/Return Loss <1.7:1/11.8 dB <1.5:1/14.0 dB <2.0:1/9.5 dB <1.9:1/10.1 dB <2.0:1/9.5 dB <2.2:1/8.5 dB with 60x60cm ext.baseplate Gain 0-1.5 dBi 1.5-2.5 dBi 2.0-3.5 dBi 5.0-7.0 dBi 4.0-7.0 dBi 5.0-6.0 dBi Gain 2.0-4.0 dBi IBi 3.c .0 dBi 5.0-7.0dBi 4.0-7.0dBi 5.0-6.0dBi with 60x60cm ext.baseplate Horizontal Beamwidth Omni(360°) <-153 dBc for 0 DIN PIM @ 2x43 dBmI ill <-150 dBc for N-Type or 4.1-9.5 DIN Input Power 50 W at ambient temperature of 77°F(25°C) J Operating Temperature -40°to 158°F (-40°to+70°C) Environmental Conditions Indoor Antenna Weight - I 1.65 lbs(7508) 1 , rn Antenna Dimensions(Diameter/Height) 13.2"/4.88" (335/ 124mm) c Flammability rating UL 94 VO `o Radome Material PC/ABS (halogen free) o_ v RoHS1l Compliant 2 _Mu ilii_ilMh_Radome Color RAL 9016 (white)* ] Plenum Rated o T 3 Approved for use in Plenum Space Listed&Tested by Intertek/ETL v a Shipping Dimensions 16.7'x15.1"x10.4"/425x385x265mm 0 0 ÷D)`Shipping Weight(Gross Weight) 5.73 lbs(2.6 Kg) *Radome can be painted with recommended paint"Krylon fusion for plastic" Copyright©2015-Galtronics Corporation Ltd. Proprietary Information.All rights reserved.Galtronics reserves the right to modify or amend any antenna or specification without prior notice. www.galtronics.com «i.j�) G A LT R O fl I CS 698-6000 Mhz,Omni Directional,In-Building Antenna A BnYLIN TECHNOLOGIES COMPANY Odeg OEe9 Odeg 00 10100; 2W O 004. 00/„.4„, ,„` bOg 4 \�,k goo \.. ., t*::#64.141‘14 — MAN& 1: ti 270.9 lib 16 00 \it 90 deg P]0 deg �de0 n0.9gO Jeg I f1*\ PriPirl *. 10°P VW Wairr / 180Ue9 MESS, 180tleg 410 MHz 710 MHz 850 MHz 1.1 Odeg Odeg g ].�0 J 00 ].00 00 •007144\.."\\ 0. j�thA.uftM5'-------0010 00 iti., Z]deg 90 tleg POdeg 490 tle92]0 deg • 0O0 v,„ liplisr Mg I *IOW *NO WirililL Art 4W. '.-.1.Sr? ftlITIO CD a) 1800. 180Eeg 160Eeg 1910 MHz 2500 MHz 5500 MHz CJ 0 0 ce 014 s,E o vso `uio N 0 NW 41E4 o Copyright©2015-Galtronics Corporation Ltd. Proprietary Information.All rights reserved.Galtronics reserves the right to modify or amend any antenna or specification without prior notice. WWW.g al I tro n I Cs.co m Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 4 ANDREW 1/2" COAXIAL CABLE Product Specifications COMMSCOPE® Qon the go Andrew Solutions '' '- AL4RPV-50 AL4RPV-50, HELIAX® Plenum Rated Air Dielectric Coaxial Cable, corrugated aluminum, 1/2 in, off white PVC jacket • This product is part of the CommScope Wired for Wireless® Solution Construction Materials Jacket Material PVC Dielectric Material PE spline Flexibility Standard Inner Conductor Material Copper-clad aluminum wire Jacket Color Off-white Outer Conductor Material Corrugated aluminum Dimensions Nominal Size 1/2 in Cable Weight 0.21 kg/m j 0.14 lb/ft Diameter Over Jacket 15.926 mm 0.627 in Inner Conductor OD 4.5720 mm j 0.1800 in Outer Conductor OD 14.046 mm j 0.553 in Electrical Specifications Cable Impedance 50 ohm ±2 ohm Capacitance 76.0 pF/m I 23.0 pF/ft dc Resistance, Inner Conductor 1.570 ohms/km j 0.480 ohms/kft dc Resistance, Outer Conductor 1.570 ohms/km j 0.480 ohms/kft dc Test Voltage 4000 V Inductance 0.190 pH/m j 0.058 pH/ft Insulation Resistance 100000 Mohms•km Jacket Spark Test Voltage (rms) 5000 V Operating Frequency Band 1 — 6000 MHz Peak Power 40.0 kW Power Attenuation 2.325 Pulse Reflection 0.5% Velocity 86.5% Environmental Specifications Installation Temperature -5 °C to +60 °C (+23 °F to +140 °F) Operating Temperature -20 °C to +85 °C (-4 °F to +185 °F) Storage Temperature -20 °C to +85 °C (-4 °F to +185 °F) General Specifications Brand HELIAX® Mechanical Specifications ©2013 CommScope, Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks, respectively,of CommScope. page 1 of 4 All specifications are subject to change without notice.See www.commscope.com for the most current information. Revised:March 18, 2013 April 8,2013 Product Specifications COMMSCOPE® AL4RPV-50 ©on the go Bending Moment 6.8 N-m I 5.0 ft lb Fire Retardancy Test Method NFPA 262/CATVP/CMP Flat Plate Crush Strength 1.4 kg/mm I 80.0 lb/in Minimum Bend Radius, Multiple Bends 127.00 mm I 5.00 in Minimum Bend Radius, Single Bend 64.00 mm I 2.50 in Number of Bends, minimum 15 Tensile Strength 79 kg I 175 lb Note Performance Note Values typical, unless otherwise stated Standard Conditions Attenuation, Ambient Temperature 20 °C I 68 °F Average Power, Ambient Temperature 40 °C I 104 °F Average Power, Inner Conductor Temperature 100 °C I 212 °F Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 806-960 MHz 1.25 19.00 1700-2200 MHz 1.25 19.00 02013 CommScope, Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks, respectively,of CommScope. page 2 of 4 All specifications are subject to change without notice.See www.commscope.com for the most current information. Revised:March 18, 2013 April 8,2013 Product Specifications COMMSCOPE® AL4RPV-50 Q on the go Attenuation Frequency (MHz) Attenuation (dB/100 m) Attenuation (dB/100 ft) Average Power (kW) 0.5 0.152 0.046 40.00 1 0.216 0.066 35.37 1.5 0.264 0.081 28.84 2 0.306 0.093 24.95 10 0.691 0.211 11.04 20 0.985 0.3 7.75 30 1.213 0.37 6.29 50 1.581 0.482 4.83 88 2.126 0.648 3.59 100 2.274 0.693 3.35 108 2.368 0.722 3.22 150 2.821 0.86 2.70 174 3.054 0.931 2.50 200 3.292 1.003 2.32 300 4.104 1.251 1.86 400 4.808 1.466 1.59 450 5.134 1.565 1.49 500 5.445 1.659 1.40 512 5.517 1.682 1.38 600 6.032 1.839 1.26 700 6.583 2.007 1.16 800 7.105 2.166 1.07 824 7.227 2.203 1.06 894 7.574 2.308 1.01 960 7.892 2.405 0.97 1000 8.081 2.463 0.94 1250 9.207 2.806 0.83 1500 10.256 3.126 0.74 1700 11.053 3.369 0.69 1800 11.439 3.487 0.67 2000 12.192 3.716 0.63 2100 12.559 3.828 0.61 2200 12.92 3.938 0.59 2300 13.276 4.046 0.57 2500 13.975 4.259 0.55 2700 14.656 4.467 0.52 3000 15.649 4.77 0.49 3400 16.928 5.159 0.45 3700 17.859 5.443 0.43 4000 18.768 5.72 0.41 5000 21.671 6.605 0.35 6000 24.42 7.443 0.31 * Values typical, guaranteed within 5% Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system ETL Certification CATVP/CMP 02013 CommScope, Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks, respectively,of CommScope. page 3 of 4 All specifications are subject to change without notice.See www.commscope.com for the most current information. Revised:March 18, 2013 April 8,2013 Product Specifications COMMSC( PE® POWERED BY DREW LDF4-50A LDF4-50A, HELIAX® Low Density Foam Coaxial Cable, corrugated copper, 1/2 in, black PE jacket Construction Materials Jacket Material PE Outer Conductor Material Corrugated copper Dielectric Material Foam PE Flexibility Standard Inner Conductor Material Copper-clad aluminum wire Jacket Color Black Dimensions Nominal Size 1/2 in Cable Weight 0.15 lb/ft I 0.22 kg/m Diameter Over Dielectric 12.954 mm I 0.510 in Diameter Over Jacket 15.875 mm I 0.625 in Inner Conductor OD 4.8260 mm I 0.1900 in Outer Conductor OD 13.970 mm I 0.550 in Electrical Specifications Cable Impedance 50 ohm +1 ohm Capacitance 23.1 pF/ft I 75.8 pF/m dc Resistance, Inner Conductor 0.450 ohms/kft I 1.480 ohms/km dc Resistance, Outer Conductor 0.820 ohms/kft j 2.690 ohms/km dc Test Voltage 4000 V Inductance 0.190 pH/m I 0.058 pH/ft Insulation Resistance 100000 Mohms•km Jacket Spark Test Voltage (rms) 8000 V Operating Frequency Band 1 — 8800 MHz Peak Power 40.0 kW Velocity 88% Environmental Specifications Installation Temperature -40 °C to +60 °C (-40 °F to +140 °F) Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F) Storage Temperature -70 °C to +85 °C (-94 °F to +185 °F) General Specifications Brand HELIAX® Mechanical Specifications Bending Moment 3.8 N-m I 2.8 ft lb Flat Plate Crush Strength 110.0 lb/in I 2.0 kg/mm ©2014 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 1 of 3 All specifications are subject to change.See www.commscope.com for the most current information. Revised:July 26, 2013 May 22, 2014 Product Specifications COMMSC( PE® , LDF4-50A POWERED BY DREW J Minimum Bend Radius, Multiple Bends 127.00 mm I 5.00 in Minimum Bend Radius, Single Bend 50.80 mm I 2.00 in Number of Bends, minimum 15 Number of Bends, typical 50 Tensile Strength 113 kg I 250 lb Note Performance Note Values typical, unless otherwise stated Standard Conditions Attenuation, Ambient Temperature 20 °C I 68 °F Average Power, Ambient Temperature 40 °C I 104 °F Average Power, Inner Conductor Temperature 100 °C I 212 °F Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 806-960 MHz 1.13 24.30 1700-2000 MHz 1.13 24.30 Attenuation Frequency (MHz) Attenuation (dB/100 m) Attenuation (dB/100 ft) Average Power (kW) 0.5 0.149 0.045 40.00 1 0.211 0.064 36.11 1.5 0.259 0.079 29.46 2 0.299 0.091 25.50 10 0.672 0.205 11.35 20 0.954 0.291 7.99 30 1.172 0.357 6.51 50 1.521 0.463 5.02 88 2.031 0.619 3.76 100 2.169 0.661 3.52 108 2.256 0.688 3.38 150 2.673 0.815 2.85 174 2.887 0.88 2.64 200 3.103 0.946 2.46 300 3.835 1.169 1.99 400 4.462 1.36 1.71 450 4.749 1.447 1.61 500 5.021 1.53 1.52 512 5.085 1.55 1.50 600 5.533 1.686 1.38 700 6.009 1.831 1.27 800 6.456 1.968 1.18 824 6.56 1.999 1.16 894 6.855 2.089 1.11 960 7.124 2.171 1.07 1000 7.284 2.22 1.05 1250 8.226 2.507 0.93 1500 9.093 2.771 0.84 1700 9.744 2.97 0.78 ©2014 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 2 of 3 All specifications are subject to change.See www.commscope.com for the most current information. Revised:July 26, 2013 May 22, 2014 Product Specifications COMMSCOPE® , LDF4-50A POWERED BY " 1800 10.058 3.066 0.76 2000 10.666 3.251 0.72 2100 10.961 3.341 0.70 2200 11.251 3.429 0.68 2300 11.535 3.516 0.66 2500 12.09 3.685 0.63 2700 12.627 3.849 0.60 3000 13.407 4.086 0.57 3400 14.401 4.389 0.53 3700 15.118 4.608 0.50 4000 15.815 4.82 0.48 5000 18.01 5.489 0.42 6000 20.055 6.113 0.38 8000 23.826 7.262 0.32 8800 25.244 7.694 0.30 * Values typical,guaranteed within 5% Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant China RoHS SJ/T 11364-2006 Below Maximum Concentration Value (MCV) ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system ©2014 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 3 of 3 All specifications are subject to change.See www.commscope.com for the most current information.Revised:,July 26,2013 May 22,2014 Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 5 ANDREW N-MALE CONNECTOR Product Specifications COMMSCOPE® ©on the go Andrew Solutions L4TNM-PSA 00.00 Type N Male Positive StopTM for 1/2 in AL4RPV-50, LDF4-50A cable (11 . • This product is part of the CommScope Wired for Wireless® Solution General Specifications Interface N Male Body Style Straight Brand HELIAX® I Positive StopTM Harmonized System (HS) Code 854420 (Coaxial cable and other coaxial electric conductors) Mounting Angle Straight Electrical Specifications Connector Impedance 50 ohm Operating Frequency Band 0 - 8800 MHz Cable Impedance 50 ohm 3rd Order IMD, typical -116 dBm @ 910 MHz 3rd Order IMD Test Method Two +43 dBm carriers RF Operating Voltage, maximum (vrms) 707.00 V dc Test Voltage 2000 V Outer Contact Resistance, maximum 0.30 mOhm Inner Contact Resistance, maximum 2.00 mOhm Insulation Resistance, minimum 5000 MOhm Average Power 0.6 kW @ 900 MHz Peak Power, maximum 10.00 kW Insertion Loss, typical 0.05 dB Shielding Effectiveness -130 dB ©2013 CommScope, Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks, respectively,of CommScope. page 1 of 3 All specifications are subject to change without notice.See www.commscope.com for the most current information. Revised: November 6, 2012 April 8,2013 Product Specifications COMMSal PE® L4TNM-PSA ©on the go Outline Drawing MATES TO A4IL—S1O-348. 3D4.2 dR FDIJIv LENT 19,Oanm WRENCH FLATS I_11____ - 4tii (022.35mm) O1tIdrnrn) 16.1 13 •6" WREN cH FLATS • Mechanical Specifications Outer Contact Attachment Method Ring-flare Inner Contact Attachment Method Captivated Outer Contact Plating Trimetal Inner Contact Plating Silver Attachment Durability 25 cycles Interface Durability 500 cycles Interface Durability Method IEC 61169-16:9.5 Connector Retention Tensile Force 890 N I 200 lbf Connector Retention Torque 5.42 N-m I 48.00 in lb Insertion Force 66.72 N I 15.00 lbf Insertion Force Method MIL-C-39012C-3.12, 4.6.9 Coupling Nut Proof Torque 176.26 N-m I 1560.00 in lb Coupling Nut Retention Force 444.82 N I 100.00 lbf Coupling Nut Retention Force Method MIL-C-39012C-3.25, 4.6.22 Dimensions Nominal Size 1/2 in Diameter 22.35 mm I 0.88 in Length 76.70 mm I 3.02 in Weight 94.71 g I 0.21 lb Environmental Specifications Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F) Storage Temperature -55 °C to +85 °C (-67 °F to +185 °F) ©2013 CommScope, Inc.All rights reserved.All trademarks identified by©or TM are registered trademarks, respectively,of CommScope. page 2 of 3 All specifications are subject to change without notice.See www.commscope.com for the most current information. Revised: November 6, 2012 April 8,2013 Product Specifications COMMSCOPE® L4TNM-PSA ©on the go Immersion Depth 1 m Immersion Test Mating Unmated Immersion Test Method IEC 60529:2001, IP68 Water Jetting Test Mating Unmated Water Jetting Test Method IEC 60529:2001, IP66 Moisture Resistance Test Method MIL-STD-202F, Method 106F Mechanical Shock Test Method MIL-STD-202, Method 213, Test Condition I Thermal Shock Test Method MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C Vibration Test Method IEC 60068-2-6 Corrosion Test Method MIL-STD-1344A, Method 1001.1, Test Condition A Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 45-1000 MHz 1.02 39.00 1010-2200 MHz 1.03 37.00 2210-3000 MHz 1.05 33.00 3010-4000 MHz 1.09 27.00 4010-6000 MHz 1.25 19.00 6010-8000 MHz 1.33 17.00 Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant by Exemption China RoHS SJ/T 11364-2006 Above Maximum Concentration Value (MCV) ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system 0 e * Footnotes Immersion Depth Immersion at specified depth for 24 hours Insertion Loss, typical 0.05-freq (GHz) (not applicable for elliptical waveguide) ©2013 CommScope, Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks, respectively,of CommScope. page 3 of 3 All specifications are subject to change without notice.See www.commscope.com for the most current information. Revised: November 6, 2012 April 8,2013 Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 6 ANDREW SPLITTERS AND DIRECTIONAL COUPLERS (PUBLIC SAFETY) Product Specifications COMMSCC9PE® C-6-TCPUSE-N-Ai6 6 dB, Low PIM Air Directional Coupler, 340-2700 MHz General Specifications Brand Andrew@ Device Type Coupler Interface N Female Color Silver Electrical Specifications Operating Frequency Band 340 - 2700 MHz 3rd Order IMD -160 dBc 3rd Order IMD Test Method Two +43 dBm carriers Average Power, maximum 200 W Coupling 6.0 dB Coupling Tolerance ±1.1 dB @ 380-2700 MHz I ±1.5 dB @ 340-380 MHz Impedance 50 ohm Insertion Loss at Frequency Band 1.8 dB @ 340-2700 MHz Isolation at Frequency Band 26 dB @ 340-2700 MHz Peak Power, maximum 1 kW Reflected Power, maximum 40 W Return Loss, minimum 20.8 dB VSWR 1.2:1 Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -25 °C to +85 °C (-13 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 23.00 mm I 0.91 in Length 211.00 mm I 8.31 in Width 76.00 mm I 2.99 in Net Weight 520.00 g I 1.15 lb ©2017 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 1 of 2 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:May 19,2017 June 30,2017 Product Specifications commsa: P C-6-TCPUSE-N-Ai6 Packed Dimensions Height 42.0 mm I 1.7 in Length 258.0 mm I 10.2 in Width 77.0 mm I 3.0 in Shipping Weight 580.00 g I 1.28 lb Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant by Exemption ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system 0 ©2017 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 2 of 2 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:May 19,2017 June 30,2017 Product Specifications COMMSCC9PE® S-2-TCPUSE-H-Ni6 Multiband Two-way Low PIM Reactive High Power Splitter, 340-2700 MHz General Specifications Brand Andrew® Device Type Splitter Interface N Female Color Silver Electrical Specifications Operating Frequency Band 340 - 2700 MHz 3rd Order IMD -160 dBc 3rd Order IMD Test Method Two +43 dBm carriers Average Power, maximum 300 W Impedance 50 ohm Insertion Loss at Frequency Band 0.25 dB @ 380-2700 MHz I 0.3 dB @ 340-380 MHz Peak Power, maximum 3 kW Power Rating, Splitting 300 W Reflected Power, maximum 300 W Split Loss 3.0 dB VSWR 1.2:1 @ 380-2700 MHz I 1.3:1 @ 340-380 MHz Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -25 °C to +85 °C (-13 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 25.00 mm I 0.98 in Length 163.00 mm I 6.42 in Width 61.00 mm I 2.40 in Net Weight 300.00 g I 0.66 lb Packed Dimensions ©2017 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 1 of 2 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:May 19,2017 June 30,2017 Product Specifications COMMSCC9PE® S-2-TCPUSE-H-Ni6 Height 45.0 mm I 1.8 in Length 180.0 mm I 7.1 in Width 98.0 mm I 3.9 in Shipping Weight 320.00 g I 0.71 lb Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant by Exemption ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system C ©2017 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 2 of 2 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:May 19,2017 June 30, 2017 Product Specifications COMMSCC9PE® S-3-CPUSE-H-Ni6 Three-way Reactive Power Splitter, 555-2700 MHz eel �f. General Specifications Brand Andrew® Device Type Splitter Interface N Female Color Silver Electrical Specifications Operating Frequency Band 555 - 2700 MHz 3rd Order IMD -160 dBc 3rd Order IMD Test Method Two +43 dBm carriers Average Power, maximum 300 W Impedance 50 ohm Insertion Loss at Frequency Band 0.2 dB @ 555-2700 MHz Peak Power, maximum 3 kW Power Rating, Splitting 300 W Reflected Power, maximum 300 W Return Loss, minimum 20.8 dB Split Loss 4.8 dB VSWR 1.2:1 ©2017 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 1 of 3 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:May 19,2017 June 30,2017 Product Specifications commsa: P S-3-CPUSE-H-Ni6 Outline Drawing �sta e�ao���WOLE 2,1 31.5 101211 147..1,1t1 25'-I 1b1.al Ed2) + 159 at2J • ea 9, A_I U. I-I Mechanical Specifications Coupling Nut Proof Torque 4.50 N-m I 3.32 ft lb Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -35 °C to +85 °C (-31 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 43.00 mm I 1.69 in Length 159.00 mm I 6.26 in Width 61.00 mm I 2.40 in Net Weight 300.00 g I 0.66 lb Packed Dimensions Height 65.0 mm I 2.6 in Length 170.0 mm I 6.7 in Width 110.0 mm I 4.3 in Shipping Weight 380.00 g I 0.84 lb Volume 1215.5 cc ©2017 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 2 of 3 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:May 19,2017 June 30,2017 Product Specifications commsa: P S-3-CPUSE-H-Ni6 Regulatory Compliance/Certifications Agency Classification ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system ©2017 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 3 of 3 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:May 19,2017 June 30,2017 Product Specifications COMMSCC9PE® S-4-TCPUSE-H-N i 6 Multiband Four-way Low PIM Reactive High Power Splitter, 340-2700 MHz General Specifications Brand Andrew® Device Type Splitter Interface N Female Color Silver Electrical Specifications Operating Frequency Band 340 - 2700 MHz 3rd Order IMD -160 dBc 3rd Order IMD Test Method Two +43 dBm carriers Average Power, maximum 300 W Impedance 50 ohm Insertion Loss at Frequency Band 0.4 dB @ 380-2700 MHz I 0.5 dB @ 340-380 MHz Peak Power, maximum 3 kW Power Rating, Splitting 300 W Reflected Power, maximum 300 W Split Loss 6.0 dB VSWR 1.3:1 © 380-2700 MHz I 1.38:1 @ 340-380 MHz Mechanical Specifications Inner Contact Plating Silver Outer Contact Plating Trimetal Environmental Specifications Application Indoor/Outdoor Ingress Protection Test Method IEC 60529:2001, IP65 Operating Temperature -25 °C to +85 °C (-13 °F to +185 °F) Relative Humidity Up to 100% Dimensions Height 61.00 mm I 2.40 in Length 198.00 mm I 7.80 in Width 61.00 mm I 2.40 in Net Weight 430.00 g I 0.95 lb Packed Dimensions Height 65.0 mm I 2.6 in ©2017 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 1 of 2 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:May 19,2017 June 30,2017 Product Specifications COMMSCC9PE® S-4-TCPUSE-H-Ni6 Length 280.0 mm j 11.0 in Width 88.0 mm 3.5 in Shipping Weight 470.00 g j 1.04 lb Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant by Exemption ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system ©2017 CommScope,Inc.All rights reserved.All trademarks identified by®or TM are registered trademarks,respectively,of CommScope. page 2 of 2 All specifications are subject to change without notice.See www.commscope.com for the most current information.Revised:May 19,2017 June 30, 2017 Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 7 EMR DUPLEXER UM corp! 65316-1/MC(5G) Mobile Duplexer Electrical Specifications Frequency Band 440-490 MHz Offset Tx-Rx 4.6-6 MHz Input Power(Max.) 50 W1nP- Insertion Loss (Typ.) 1.2 dB -..' lik Isolation (Min. /Typ.) 70/80 dB Nom. Impedance 50 0 VSWR(Max.) 1.25:1 \ \. \\\ RF Connectors BNC Female Mechanical Specifications .:��'y .� ' Finish Black s r kik Cavity Size/Quantity 1"/6 Overall Size (HxWxD) 1.2"x 6" x 9.5" (30 x 152 x 241 mm) Ship Weight 5 lbs (2.3 kg) Environmental Specifications Operating Temp. Range -22 to 140 °F (-30 to +60 °C) - 6.09n. - 4.10in. CH 1 S 1 1 109 MAO I❑ d9/ REF 0 dB 1. --33.83 dB 1.27M, - - 2551n _ 0.10in. 0.160. CH2 521 log MA 4 10 d8/ REF 0 dB L-1. 1668 dB -I O- - - -.. i ' O.fiBin. ,=3. 12 5C0 MHz 1- L Co, a --1.2701 dB 68,412 MHz MARKER 1 453. 1125 MH _ 7.61in. V 8.101n. 9.Ofiin. I.i 1466b4WMHzGar �11k Avg - 1B 11,11,1414k2 D.111n..r -- _ x Smo ] A III OSDin. —1R n— 455. - _ ' /V `-_ CENTER 465.912 500 MHz SPAN 10.000 000 MHz 11 11 1 H D.17in. - 2.55in. - r- 5.411n. I All product specifications subject to change without notice. Copyright©2015 EMR Corporation.All rights reserved. 17431 N. 25th Avenue Phoenix, Arizona 85023- Phone: (623)581-2875-Toll Free: (800) 796-2875- Fax: (623)582-9499 Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 8 MICROLAB HYBRID COUPLER • Hybrid Coupler, CA-14 series 1111,0 t1icrcIab Ultra Wideband Low PIM Wireless Band Models 350- 5,850 MHz, N, 7-16 or 4.3-10 Rev. F • Multi-Band Range • High Isolation, Low VSWR and Loss • Low Specified PIM ,� � - • 200 Watt per Input Continuous '' -40 Average Power up to 2.1 GHzt • Meets European Rail Standard EN50155:2001 (Class T3) ' • High Reliability, Moisture sealed 111 • RoHS compliant LOW PIM Microlab Model Hybrid Couplers have been designed to meet the special needs of the wireless market.They are most commonly used to combine two wireless carriers in the operating band to a single antenna feed or distribution cable.This requires the termination of one output port in 50Q and results in a 3 dB loss in each signal.In situations where two similar feeds are required,as required for an in-building application,both outputs may be used eliminating the need for a termina- tion and the 3 dB loss.For low PIM terminations see TK-20 series. This CA-14 series,which now incorporates the wider frequency range of the CA-13 series,has been designed for sys- tems requiring signal combining over all the wireless bands from 350 to to 5,850 MHz.Isolation has been maximized and passive intermodulation (PIM) minimized. Model Number/Conn Frequency Isolation Coupling VSWR Coupling: 3 dB nominal 7-16 N 4.3-10 Range,MHz dB &Loss,dB Max Power/Input: 200W up to 2.1 GHzt, 3.0 kW pk 350-1,500 >25 dB 3.2±0.5 1.20:1 Impedance: 5052 nominal 1,500-2,500 >20 dB 3.4±0.5 1.30:1 Environment: -40°C to+70°C,IP64 CA-14D CA-14N CA-14E 2,500-2,700 >18 dB 3.5±0.7 1.50:1 PIM (Intermod): -161 dBc(+43dBm x2) Finish:Housing: Passivated aluminum 2,700-4,900 >18 dB 3.6±0.8 1.50:1 Connectors: Triplate, (f) 4,900-5,850 >18 dB 3.6±1.0 1.50:1 Weight,nom: 2.65 lb.,1.20 kg *Units also available with male output connectors. t De-rated by 13.3 w per 1 Ghz from 2.1 to 5.85 Ghz (max 150 Watts/input at 5.85 GHz) '4.3-10 7-16 DIN 8.45 FEMALE FEMALE [214.63] TYPE'N' 1.01 6.42 FEMALE [25.75] - -I- [163.13] I 9 .6 .86 � [24i38] IIW 21.97] 11 11 [1.74 8.80] • 1 • , ° INPUT J1 INPUT J2 3.08 DC Paths [78.23] 11 to J4 6.60 [68.07] J2 to J3 . . OUTPUT J4 OUTPUT J3 O = /111.011 I 0.20 THRU ,I 1 ,I1a I1 -I 4 PLACES I I .20 .82 I .20 _ 8.05 [5.081 .51 [20.77]I` [5.08] [204.47] - [12.85] 1.00 1.30 - [25.40] [33.02] Dimensions in inches[mm] Note:Specifications are subject to change without prior notification. 20SEP2016 Microlab,A Wireless Telecom Group Company,25 Eastmans Road,Parsippany,NJ 07054 Tel:(973)386-9696•sales@microlab.fxr.com•www.microlab.fxr.com•Fax:(973)386-9191 Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 9 WESTELL YAGI ANTENNA 746-896 MHz Yagi Antenna (11 dBi) Model Numbers • CSI-AY/746-896/11 Frequency Range • 746-896 MHz (v4.444.1.i.4 Features & Benefits • 11 dBi Gain • 8 Elements • Hermetically Sealed Driven Element • Rugged Lightweight Design • Stainless Steel Hardware 746-896 MHz Yagi Antenna,11 dBi • Broad Bandwidth Radiation Patterns 4>AeF14 f$94.7&1440,11 1444.44A tt' 1 0\954,4a.kjte 04 kWh-WNW Vertical Horizontal Electrical Specifications Mechanical Specifications Gain 11 dBi Number of Elements 8 VSWR <1.7:1 Connector N-Female Horizontal Beamwidth 48° Lightning Protection Direct Ground Vertical Beamwidth 42° Rated Wind Speed 134 mph(200 kph) Polarization Vertical Dimensions 33.1 x 8 x 2.2 in Maximum Input Power 100 Watts Antenna Weight 1.76 lbs Electrical Downtilt 0° Mounting Hardware U-Bolt Front-back Ratio >16 dB Included Mounting Hardward Fits 1 7/8"OD Pipe Specifications subject to change without notice. WESTELL Copyright©2015 by Westell,Inc.All Rights Reserved.Westell,ClearLink,Kentrox,and Optima WESTELL.CO M Management System are registered trademarks of Westell,Inc.All other names are trademarks of their respective owners.Information is correct at time of printing and is subject to change without notice. Westell,Inc.is an Equal Opportunity/Affirmative Action employer. 030-200218 rA 01/12/15 Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 10 ROHN ROOF MOUNT ROOF MOUNTS - FRM RM FRM NON - PENETRATING The FRM mount is a lightweight mount and is galvanized for corrosion protection.The FRM mount is easily shipped via UPS. Order(1)optional FRMMAT(1/8"thick)or(1)optional FRMPAD(3/8"thick)for a protective barrier between the mount and the roof. Order(1)optional SCK150 • safety cable kit(3/8"x 150'). 1.25"to 2.38"Mast Tube Diameters 2.5'and 5'Overall I, Mast Heights (See Mast Descriptions) 16"Nominal Blocks O OO .4 . . 3'Square FRM BALLAST REQUIREMENTS Effective Zero Vmax at centroid of projected area,(MPH) Projected Ballast Velocity Vs MAST SPECIFICATIONS Area(EPA) (LBS) Load (MPH) (FT') (PSF) h=2 FT h=3 FT h=4 FT h=5 FT Mount Mast Mast Description&Height 100 12 140 135 110 96 85 Part No. Part No. P2 200 24 198 188 153 133 119 FRM125 FY202 1.25"O.D.x 16 GA.x 5.0'(PG) 300 36 242 222 182 157(154) 141 (131) 400 48 280 269 219(197) 1 190(154) 1170(131) FRM150 FY203 1.50"O.D.x16GA.x2.5'(PG) 100 12 99 96 78 68 60 FRM 166 FY204 1.66"O.D.x 16 GA.x 2.5'(PG) 4 200 24 140 133 108 94 84 300 36 171 157 129 111 99(93) 400 48 198 190 155(139) 134(109) 120(93) FRM238 FY205 2.38"O.D.x 0.154"wall x 2.5'(HDG) 100 12 81 78 64 55 49 FRM225 FY205SP 2.25"O.D.x 14 GA.x 5.0'(HDG) 6 200 24 114 108 88 77 68 300 36 140 128 105 91 (89) 81 (76) FRM238SP5 FY253 2.38"O.D.x 0.154"wall x 5.0'(HDG) 400 48 161 155 127(114) 110(89) 98(76) PG=Pre-galvanized mast h=Distance from support surface to centroid of EPA. HDG=Hot-dip galvanized mast Vs=Effective wind velocity resulting in sliding on a flat surface with a.50 coefficient of friction. Vmax=Effective wind velocity based on strength or overturning. NOTE:The velocities in ( )apply to the FRM125 mount when the strength of the FRM125 mast governs. alma 1HW 6 Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard 0 2011 ROHN PRODUCTS LLC Products LLC Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 11 POLYPHASER LIGHTNING PROTECTOR V REVISIONS REV. DESCRIPTION ECN DATE APPROVED E REFER TO ECN 12864 9/9/14 JJ 1'I'l,l,l 0 \\ 0)0'442-4111141 ) )0' 3.61[91.7] 01.18[30] II111111111111111111111111111IIIIIIIIIIIIIIIIIIIIIIIIIIIII1111111111111111111111 n 010001 Mil t ulllllllll IIIIIIIIII J 2X 5/8-24 U N E F-2A FEMALE 'N'CONN 2X .95[24.1] .53[13.5] MAXIMUM CHARACTERISTICS APPLICATION: DC SHORT/RF ONLY(NO POWER SUPPLY PROVISIONS) BULKHEAD MOUNT BI-DIRECTIONAL WEATHERPROOF WHEN INSTALLED FREQUENCY RANGE: 698MHz TO 2.7GHz @-26dB RETURN LOSS MAX SURGE: IEC 61000-4-5 8/20IJs WAVEFORM 40kA MAX 20kA MULTIPLE INSERTION LOSS: HARDWARE KIT INCLUDES: <_0.1 dB CONTINUOUS POWER: QTY DESCRIPTION 500W @ 920MHz 1 NUT 5/8-24 303 HEX SS (750W @ 50°C) LET THROUGH VOLTAGE: 1 WASHER 5/8 410 SS <±200mV FOR 3kA @ 8/20ps WAVEFORM 1 SILICONE 0-RING 019 THROUGHPUT ENERGY: <_5nJ FOR 3kA @ 8/20ps WAVEFORM CUSTOMER APPROVAL: DATE: TEMPERATURE: -50°C TO +85°C STORAGE/OPERATING ALL DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. VIBRATION: 1G @ 5Hz TO 100Hz UNLESS OTHERWISE SPECIFIED DRAWN DATE MATERIAL: LEADING DIMENSIONS ARE INCHES RD 02/09/2012 PolyPhaser BODY: TRI-PLATED BRASS DIMENSIONS IN[]ARE MILLIMETERS ENG APPD PTFE: DIELECTRIC JJ 5/15/12 CENTER PINS: TRIM TOLERANCES: PRODUCT MGR ENVIRONMENTAL: FRACTIONS=± 1/32 .XX=± .03 CP 5/15/12 TITLE MEETS IEC 60529 IP67 WHEN CONNECTED ANGLES=± 1 ° .xxx=± .010 MARKETING APPD BI-DIRECTIONAL BROADBAND DC MEETS BELLCORE#TA-NWT-000487 MATERIAL LJ 5/15/12 PROJECT NO. SHORT FILTER 'N' PROCEDURE 4.11, 120MPH WIND DRIVEN RAIN INTRUSION TEST CUSTOMER SPECIFICATION THIRD-ANGLE PROJECTION SIZE CAGE PART NUMBER REV CE COMPLIANT THESE COMMODITIES,TECHNOLOGY OR SOFTWARE WERE EXPORTED FROM THE NOTICE:THE INFORMATION AND DESIGN RoHS COMPLIANT UNITED STATES IN ACCORDANCE WITH THE IN THIS DOCUMENT IS THE PROPERTY B 30992 TSX-N F F E EXPORT ADMINISTRATION REGULATIONS. 0 — OF TRANSTECTOR SYSTEMS. ALL DIVERSION CONTRARY TO U.S.LAW PROHIBITED. RIGHTS RESERVED. SCALE PROD CAT DOCUMENT NAME SHEET OF 1:1 RFP TSX-NFF-C 3 3 ©2014 Smiths Power.All rights reserved. A Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 12 MINUTEMAN UPS Size My UPS.com Conflate pour peva prdectionmNulin lonind Minuteman UPS home I Sizing Home I Specs Page Interactive Sizing UPS Specifications: (Email/Fax this page) DISCLAIMER: Back-up runtime information 0 1500 VA On-line Rack/Wall/Tower UPS with 6 outlets is based on estimates.Actual runtime may vary depending upon the power factors of the protected equipment and the condition of the UPS batteries. SizeMyUPS information is provided for reference only. It is provided "as is"without warranty of any kind, express or implied. Model: EDI 500RM2U with 1 BP48RTEXL Battery Pack Buy this product Products specifications are On-BatterysubOutput Waveform: True sine wave notice.iePleasetchange without p contact a Manufacturer's Suggested Retail Price: $2,018.00 USD*battery pack(s)included in price (48 Minuteman representative Contiguous U.S. States Only) for more information. Applications: Voice and Data Networking, Servers, Sensitive Electronics Warranty: 3 Years-Parts&Labor Including Batteries UPC: 784755152466 Description: The Endeavor ED1500RM2U is a 1500VA/1200W 120 VAC true on-line, double-conversion, extended runtime rack/wall/tower UPS designed for critical, power-sensitive electronic environments. Back-up time -full load: 63.8 minutes Back-up time -half load: 158.8 minutes Back-up time at defined RATED load of 120 WATTS: 2,321.7 minutes Runtimes for small loads of less than 10 percent of the stated capacity of a given UPS may vary greatly. Please call to confirm most accurate runtime for small loads. Features: • Floor-standing tower, 19-inch rack and cabinet installation kits included • 23-inch rack or cabinet installation kit optional • Wallmount installation kit optional • 3.5-inch (2U)rack/tower case style • Up to a 0.8 power factor(in watts)for larger capacities • Output receptacle control for non-critical load shedding capability • Extended runtime using external battery packs • Independent battery pack chargers to reduce battery recharge times • Simultaneous RS-232, USB and SNMP communications (SNMP communications card sold separately) • Minuteman®SentryPlusTM UPS monitoring and control software • Front panel display with load/battery meter and status indicators • Three-year non-prorated warranty(including batteries) • Dedicated remote Emergency Power Off(EPO) port • Hot-swappable batteries • RoHS compliant • $200,000 Minuteman Platinum Protection Plan®(U.S. and Canada only) Properties: Device type: Uninterruptible Power Supply Input plug type: 5-15P '° Input voltage: 110/120 Output voltage: 110/120 Number of fully protected outlets: 6 (5-15R) 'a Number of surge protected only outlets: None Phone/modem (RJ-11) protection? Yes Network(RJ-45) protection? Yes No. of serial (DB-9) ports: 1 No. of dry contact ports: 1 USB port: Yes Battery: User replaceable battery? Yes No. of internal batteries: 1 Replacement battery description: Battery module Replacement battery part no.: BM0036 Replacement battery suggested retail price: $219.00 USD (each) Technical Attributes: SNMP manageable? Yes Power in Watts: 1200 EMI/RFI filtering? Yes Max. energy dissipation: 800 (Joules) Protected equipment insurance value: $200000 USD (US and Canada Only) Switchover time: None Software: *Operating system shutdown software included: Yes Op. System(s) supported by SentryPlus software: Windows 10 (32-bit/64-bit), 8 (32-bit/64-bit), 7 (32-bit/64-bit), Vista (32- bit/64-bit), Server 2008 R1 (32-bit/64-bit), Server 2008 R2 (64-bit), Windows XP/2000/2003, Red Hat Linux, SuSE Linux, FreeBSD, and other Unix/Linux systems Product Dimensions (in inches) (does not include any external battery packs): Length: 17.30 Width/Depth: 17.00 Height: 3.50 Weight: 43.12 lbs. Email or Fax this page: (*Indicates required field) *To (Name): *To: Fax Number(if -include area faxing): code OR Email Address: *From (Name): *From (Email Address): Add Notes (250 char max): Email a copy to the From Email Address (for Email Send Email/Fax only) content Enhancee aSC J LIflwscr Welcome Mac Safari User! Powered by: MINUTEMAN UPS and optimized for use with any browser DISCLAIMER: Back-up runtime information is based on estimates. Actual runtime may vary depending upon the power factors of the protected equipment and the condition of the UPS batteries. SizeMyUPS information is provided for reference only. It is provided "as is" without warranty of any kind, express or implied. Products specifications are subject to change without notice. Please contact a Minuteman representative for more information. MINUT N010-2 , ® Minuteman® Endeavor' Series Power Technologies On-line Uninterruptible Power Supply ED1000RM(T)2U - 1000VA/800W I ED2000RM(T)2U - 2000VA/1600W ED1500RM(T)2U - 1500VA/1200W ED3000RM(T)2U - 3000VA/2100W Endeavor UPS Model ED2000RM2U :I' _'_. J .J 71' ' J J _ I k:I I I - , , - : oo I The Minuteman® Endeavor'"" Series on-line • Floor-standing tower, 19-inch rack and cabinet ' instuninterruptible power supply combines double- allation kits included conversion technology with industry-leading • 23 inch rack or cabinet installation kit optional features in a versatile case design that allows the • Wallmount installation kit optional units to be installed in many different formats and • 3.5-inch(2U)rack/tower case style environments. • Up to a 0.8 power factor (in watts) for larger capacities In developing one of the best-valued,highest quality • Output receptacle control for non-critical load UPS products on the market,the Endeavor Series has shedding capability these standard features: • Extended runtime using external battery packs - • Independent battery pack chargers to reduce 1,� battery recharge times w. • Simultaneous RS-232, USB and SNMP communications • Minuteman° SentryPlus'" UPS monitoring and control software • Front panel display with load/battery meter and status indicators • Three-year non-prorated warranty (including batteries) .P • Dedicated remote Emergency Power Off(EPO) - port I • 120V and 208V models available el k2.--..— • Hot-swappable batteries �� ,• • RoHS compliant • $200,000 Minuteman Platinum Protection Plan° (U.S. and Canada only) Endeavor UPS Model ED2000RM2U with tower mount stand provided(standard) •. , y --- - , • ;pc. :. • - ♦•♦ t'. • •'"• •" , -'• VW t ' www.minutemanups.com•www.sizemyups.com • www.sizemypdu.com • www.comparemyups.com MINUTEMAN® ENDEAVOR SERIES UNINTERRUPTIBLE POWER SUPPLY The Endeavor Series is rich in standard features and optional Output Receptacle Control:The ability to extend the runtime accessories allowing users to order"off the shelf"products and of critical devices during an extended blackout is handled yet retain the flexibility previously only available as a special through the Endeavor's load shedding function. Each model order product. in the Endeavor Series comes with two independently-circuited receptacle segments. Through the use of Minuteman's Standard features ONLY offered on the Endeavor Series: SentryPlus software or communication with the UPS through an Ethernet/SNMP connection,users can either turn on,off,or • Three-year non-prorated warranty (including batteries) reset each segment independently of the other. By reducing • RoHS compliancy for all models the load amount on the UPS, the runtime of critical devices • Rack/Tower/Wallmount installation formats on the UPS battery can be extended. • Free SentryPlus software included COMMUNICATION FEATURES • Independent battery pack chargers Simultaneous RS-232,USB and Ethernet/SNMP Communications: • Concurrent communications via RS-232,USB and optional The Endeavor Series provides users with the ability to SNMP card communicate with the UPS simultaneously through three separate protocols: RS-232, USB and SNMP Users can now ELECTRICAL CHARACTERISTICS directly connect, and manage, the UPS from multiple stand- Output Power Factor: All Endeavor models up to 2000VA alone, or networked, computers. By including concurrent come with a 0.8 output power factor that increases the watt Ethernet communications, (SNMP or direct IP address), capacity of the units. Offering larger capacities in smaller the Endeavor Series can provide detailed monitoring and UPS VA sizes reduces the overall cost of the UPS solution for a management to many various environments. specific load requirement. The 3000VA model comes with a 0.7 power factor that provides 2,100 watts capacity in a 3.5 OTHER FEATURES inch (2U) rack space. RoHS Compliancy: Recognizing the benefit of being environmentally conscious, Para Systems developed the Output Voltage: All units in the Endeavor Series produce an Endeavor Series to be compliant with the European Economic electrical signal that does not vary from nominal voltage by Unions directive on the reduction of hazardous substances more than 2%.Tightly regulating the output voltage increases (RoHS),in electronic equipment. the quality of power to connected equipment adding to its life expectancy, which lowers the total cost of ownership to Manual and Automatic Self-Testing: The Endeavor Series is users. designed to proactively notify users of any impending faults or failures with the UPS. This allows for preemptive repair Total Harmonic Distortion(THD):THD is the distortion of a normal or replacement of components or batteries preventing AC electrical signal commonly caused on UPS products when unexpected downtime caused by the UPS. connected loads near the capacity of the units.This distortion can create internal heat build-up on sensitive equipment not Dedicated EPO Port: This direct access port allows users to designed to allow for these altered AC signals.The Endeavor perform an immediate remote shutdown of the UPS in cases Series maintains an output AC signal, at all times and with all of emergency or when access to the UPS is restricted or loads,within 2%of a true sine wave. inconvenient. Input Breaker Load 1 Load 2 _ Option Slot 0 I I • Clir 41,0 , )11113 . 11171111..Z.: 11.1 Ilk (\(*n 41: 10 Ft. IN OUT Remote RS-232 USB Power Cord Network EPO Surge Protection Connection Dn Back of Endeavor UPS Model ED 1000RM2U www.minutemanups.com 800.238.72721 +1 972.446.7363 MINUTEMAN ENDEAVOR SERIES UNINTERRUPTIBLE POWER SUPPLY BATTERY CHARACTERISTICS LED FRONT PANEL DISPLAY Extended Runtime Capability: All models in the Endeavor The LED indicators on the OWL BYPASS PAULY Series come standard with internal batteries. To protect Endeavor Series provide OBI.fAPO critical devices through extended blackouts,the Endeavor many diagnostic details // Q Series utilizes external battery packs that can be daisy- about the condition of the `••••_.=•• =•✓ chained in unlimited quantities to provide a virtually UPS as well as the utility input ,' unlimited amount of runtime. power. These indicators can . • aM .n BATT IOW ;VIM TEST provide visual confirmation of Fast Battery Recharge:With independent chargers in each anticipated battery failures or Endeavor Series battery pack offered for the Endeavor Series,the maximum UPS faults so that preventatives Eot000R+tu recharge time for depleted batteries is 4-8 hours,no matter maintenance can be how many battery packs are installed on a UPS. Without performed on the UPS.The Endeavor UPS also comes with these chargers,if more than one battery pack is used battery a LED meter that measures both connected load capacity charging could take more than an entire day. and battery runtime capacity.The LED panel is designed so Battery Pack Models:Because each UPS has different battery that it can be oriented vertically or horizontally depending requirements to support its maximum load capacity, the on the installation format of the UPS. Endeavor Series uses battery packs sized to match each PARA SYSTEMS SERVICE UPS model: Features and value are not the only assets of the Endeavor Series.Para Systems offers some unique resources to assist in • ED1000RM2U and ED1000RMT2U-EDBP24XL the proper selection and sizing of a UPS installation: • ED1500RM2U and ED1500RMT2U-EDBP48XL • minutemanups.com-Providesfullproductspecifications, • ED2000RM2U and ED2000RMT2U-EDBP48XL literature and support documents as well as contact • ED3000RM2U and ED3000RMT2U-EDBP72XL information. • SizeMyUPS.com-Provides customized UPS sizing solutions Battery Technology:All Endeavor units and battery packs use as well as a library of common equipment loads to assist valve-regulated lead-acid batteries (VRLA).All are safe for you in getting the proper UPS solution. any type of freight transport:air,sea or ground. For added • CompareMyUPS.com-Provides a competitive feature protection,all Endeavor UPS models ship with these batteries analysis of Minuteman UPS products versus other disconnected. A ''Quick Installation Guide" is included in manufacturers. each Endeavor box to detail how to connect the batteries • SizeMyPDU.com - Provides a customized website for before turning the units on. selecting a specific Minuteman PDU product for any installation. Hot-Swappable Batteries:All models in the Endeavor line offer battery replacement, through the front panel of the UPS, In addition to web resources, Para Systems offers personal without having to remove the UPS from service.Connected support of all our products through our customer support loads are protected from voltage anomalies and spikes and department and highly-trained sales staff. surges while the batteries are being replaced. MINUTEMAN SENTRYPLUS SOFTWARE Minuteman's SentryPlus 1MINUIIM4NSenIrVlusMonibr Ilr151%1 SentryPlus Features Include: s.bM UPS monitoring and control a °ln ups software comes includedi ;� _. -f° ... • SNMP/Ethernet compatibility with each Endeavor UPS �' m ° • Concurrent monitoring through single or multiple unit at no extra charge. 1••••••1° computers via RS-232, USB and Ethernet connections SentryPlus is compatible • "" • Monitor and control multiple UPS devices from a single with Windows (XP, 2000, ""07„: :" application session Server 2003, NT 4.0, ME ° }� Perform scheduled shutdowns and restarts and 98), Unix and Linux o • A • Program e-mail, pager or network broadcast of user- operating systems. With - - °- °�� °tt`°`°°°°" " defined UPS events SentryPlus software users c. i nd control both new and previously sold or installed Minuteman UPS products • Full diagnostic and event reporting on a connected network from one application session.The • Realtime graphical displays of user-defined UPS and ease of installation,ease of use,and backward compatibility utility conditions makes it the best software of its kind. • Record and save graphical event and history logs for future analysis www.minutemanups.com 800.238.72721 +1 972.446.7363 Minuteman® Endeavor" Series On-line UPS Specifications MODEL ED1000RM2U ED1500RM2U ED2000RM2U ED3000RM2U (ED1 000RMT2U) (ED1 500RMT2U) (ED2000RMT2U) (ED3000RMT2U) GENERAL Maximum Power Capacity (VA/Watts) 1000/800 1500/1200 2000/1600 3000/2100 Topology On-line Uninterruptible Power Supply Power Factor 0.8 0.7 Battery and Surge Protected [6]5-15R [6] 5-15/20R& [1] L5-20R [6] 5-15/20R& [1] L5-30R Receptacles ([4] 6-15R) ([4] 6-15/20R& [1] L6-20R) ([4] 6-15/20R& [1] L6-30R) Input Connection (with 10 ft power cord) 5-15P (6-15P) 5-20P (L6-20P) L5-30P (L6-30P) Mounting/Installation Rackmount,tower and wallmount INPUT Nominal Voltage 120VAC (208VAC) Voltage Range 80 138VAC(160-280VAC) 90-138VAC (160-280VAC) Frequency Range 50/60Hz+/-6Hz Auto-sensing Power Factor Correction >_97%at full load OUTPUT NON-BATTERY OPERATION Voltage/Frequency Range 117.6- 122.4VAC (204-212VAC) /50/60Hz±6Hz Wave Form True sine wave Efficiency(Line Mode) >87%(full load) OUTPUT BATTERY OPERATION Nominal Voltage 120VAC (208VAC),User selectable: 1 10VAC (240VAC) Voltage Regulation Nominal±2%until low battery warning Frequency 50/60Hz±0.1 Hz unless synchronized to line Voltage Total Harmonic Distortion T.H.D. <-3%at full rated linear load Dynamic Response ±5%at 100%load change in 30ms Transfer Time Oms Runtime:Half Load/Full Load (minutes) 13/4 15/5 BATTERY SYSTEM Battery Type Sealed,non-spillable,maintenance free,value regulated lead acid Typical Recharge Time 8 hours from total discharge Typical Battery Life 3-5 years,depending on discharge cycles and ambient temperature System Voltage 24VDC 48VDC 72VDC Internal Battery Module BM0035 BM0036 BM0037 BM0032 SURGE PROTECTION AND FILTERING Surge Energy Rating (Joules) 800J (600J) Surge Current Capability 6500Amps total Surge Response time Ons (instantaneous) normal mode;5ns common mode Noise Filter normal and common mode EMI/RFI suppression Audible Noise at 1 m 3 ft. <45dBA <60dBA ENVIRONMENTAL Operating (max)/Storage Temperature +32 to+104°F(0 to 40°C)/+5 to+113°F (-15 to+45°C) Operating/Storage Humidity 95%non-condensing Operatin•/Stora.e Elevation 0 to 10,000 ft 0 to 3,000 m /0 to 50,000 ft 0 to 15,000 m PHYSICAL Size-Net(H x W x D) in 3.5 x 17.3 x 13.1 in 3.5 x 17.3 x 17 in 3.5 x 17.3 x 24 in Size-Net(H x W x D) mm 89x440x335mm 89x440x432mm 89x440x610mm Size-Shipping (H x W x D) in 9 x 20 x 23.6 in 9 x 23.6 x 39.4 in Size-Shipping (H x W x D) mm 230 x 508 x 600 mm 230 x 600 x 1000 mm Wei•ht-Net lb k• /Shippin• 28.6/39 lb 13/17.5 k• 46.2/55 lb 21/25 k• 110.9 lb 50.4/57.3 k• BATTERY PACKS Battery Pack EDBP24XL EDBP48XL EDBP72XL Typical Recharge Time 8 hours maximum Size-Net(H x W x D) in 3.5 x 17.3 x 13.1 in 3.5 x 17.3 x 17 in Size-Net(H x W x D) mm 89 x 440 x 335 mm 89 x 440 x 432 mm Size-Shipping (H x W x D) in (mm) 9 x 20 x 23.6 in (230 x 508 x 600 mm) Weight-Net lb(kg) 39.6 lb (18 kg) 66 lb (30 kg) 55 lb(25 kg) Weight-Shipping lb (kg) 49 lb (22 kg) 75 lb (34 kg) 64 lb(29 kg) REGULATORY COMPLIANCE Safety and Approvals RoHS Compliant,UL,cUL,CE,FCC Class B for 1000KVA,Class A for 1500,2000,3000KVA and Battery Packs Warranty/Platinum Protection Plan Three-year non-prorated warranty/$200,000(U.S.and Canada only) Para Systems, Inc./Minuteman UPS ® ® [ OHS1455 LeMay Drive, Carrollton,TX 75007 U.S.A. (` pliant 800.238.7272 +1 972.446.7363 Fax+1 972.446.9011 c is © Copyright 2007, Para Systems, Inc. Product specifications are subject to change MINY without notice. Minuteman and Minuteman Platinum Protection Plan are registered Power Technologies From Para Systems,Inc. trademarks and Endeavor and SentryPlus are trademarks of Para Systems,Inc. PN-34000298-01-07 Vail Valley Medical Center Emergency Responder Radio Coverage System Product Data Submittals TAB 13 HOFFMAN NEMA ENCLOSURE PENTAIR WALL-MOUNT ENCLOSURES CONCEPTTMWALL-MOUNT ENCLOSURES CONCEPTIM,TYPE 4 AND 12 SPECIFICATIONS • 14, 16 or 18 gauge steel(see table) • Seams continuously welded and ground smooth . • Corner-formed doors % • Simple easy-to-remove and install hinge pins with built-in captivation clip • High-torque threadless studs and fasteners on door 1171*. • Minimum-width body flange provides maximum door opening (210 degrees) • • External formed body flange • Panel mounting studs fit optional CONCEPT panels and other accessories ii • Mounting holes in back of body for optional external wall-mount • • brackets • • Hidden hinges • Doors are interchangeable and easily removed by pulling clip- style hinge pins • Seamless foam-in-place gasket • Quarter-turn slotted latch(es) • Door alignment device on doors wider than 30 in. • Four hinges on 60-in.-high enclosures INDUSTRY STANDARDS • Grounding stud on body;bonding provision on door(except Wall-mounting brackets required to maintain UL/CSA external window-door models) mounting requirement. • Provisions for thermoplastic data pocket(right-hand hinged door on two-door models) CONCEPT solid single-door,door with window and flush mount • Hardware kit with panel mounting nuts,panel grounding models hardware and sealing washers • Single-door enclosures have a three-point latch system on UL 508A Listed;Type 4, 12;File No.E61997 enclosures where A is equal to or greater than 42-in.with cUL Listed per CSA C22.2 No.94;Type 4, 12;File No.E61997 quarter-turn,slotted latch NEMA/EEMAC Type 4, 12, 13 • Window-door enclosures have a clear polycarbonate window Yp flush with door surface CSA, File No.42186:Type 4, 12 • Mounting frame on flush-mount enclosures extends completely VDE IP66 around enclosure IEC 60529,IP66 • Two-door enclosures have a overlapping door design which provides full-width access CONCEPT two-door models • Two door enclosures have a three-point latch system on right- UL 508A Listed;Type 12;File No.E61997 hand hinged door furnished with flush slotted insert cUL Listed per CSA C22.2 No.94;Type 12;File No.E61997 • Illustrated instruction sheet NEMA/EEMAC Type 12 FINISH CSA, File No.42186,Type 12 Two standard finishes are available:ANSI 61 gray or RAL 7035 VDE IP 55 textured light-gray polyester powder paint inside and out. IEC 60529,IP55 ACCESSORIES APPLICATION Door Stop Kit CONCEPTI" Enclosures are ideal for machine control applications. Handles With streamlined styling,flush quarter-turn latches and an Lock Inserts attractive,durable finish.Available in solid or window single-door CONCEPTTM' Panels and two-door landscape,flush-mount and sloped-top versions for Mounting-Bracket Kits application and mounting flexibility.Two-door landscape models provide full-width access and easy panel installation. MODIFICATION AND CUSTOMIZATION Hoffman excels at modifying and customizing products to your specifications.Contact your local Hoffman sales office or distributor for complete information. BULLETIN:CW1 1 MILD STEEL SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec-00286 H WALL-MOUNT ENCLOSURES CONCEPT-I"'WALL-MOUNT ENCLOSURES flt7lfrilOteld Conductive Panel Size Mounting CONCEPT D x E GxH J Catalog Number AxBxC in./mm Finish Door Ga. Body Ga. CONCEPT Panel Panel in./mm in./mm Latches qty. Latches style in./mm CSD362410LG 36.00 x 24.00 x 10.00 RAL 7035 Lt.Gray 14 16 CP3624 CP3624G 34.20 x 22.20 34.50 x 22.50 2 Quarter-turn 5.00 914 x 610 x 254 869 x 564 876 x 572 127 CSD363010 36.00 x 30.00 x 10.00 ANSI 61 Gray 14 14 CP3630 CP3630G 34.20 x 28.20 34.50 x 28.50 2 Quarter-turn 5.00 914 x 762 x 254 869 x 716 876 x 724 127 CSD363010LG 36.00 x 30.00 x 10.00 RAL 7035 Lt.Gray 14 14 CP3630 CP3630G 34.20 x 28.20 34.50 x 28.50 2 Quarter-turn 5.00 762x762x254 869x716 876x724 127 CSD363610 36.00 x 36.00 0 10.00 ANSI 61 Gray 14 14 CP3636 CP3636G 34.20 x 34.20 34.50 x 34.50 2 Quarter-turn 5.00 914 x 914 x 254 869 x 869 876 x 876 127 CSD363610LG 36.00 x 36.00 x 10.00 RAL 7035 Lt.Gray 14 14 CP3636 CP3636G 34.20 x 34.20 34.50 x 34.50 2 Quarter-turn 5.00 914 x 914 x 254 869 x 869 876 x 876 127 CSD423610 42.00 x 36.00 x 10.00 ANSI 61 Gray 14 14 CP4236 CP4236G 40.20 x 34.20 40.50 x 34.50 1 3-point 21.00 1067 x 914 x 254 1021 x 869 1029 x 876 533 CSD42361OLG 42.00 x 36.00 x 10.00 RAL 7035 Lt.Gray 14 14 CP4236 CP4236G 40.20 x 34.20 40.50 x 34.50 1 3-point 21.00 1067 x 914 x 254 1021 x 869 1029 x 876 533 CSD482410 48.00 x 24.00 x 10.00 ANSI 61 Gray 14 14 CP4824 CP4824G 46.20 x 22.20 46.50 x 22.50 1 3-point 24.00 1219 x 610 x 254 1173 0 564 1181 x572 610 CSD48241 OLG 48.00 x 24.00 x 10.00 RAL 7035 Lt.Gray 14 14 CP4824 CP4824G 46.20 x 22.20 46.50 x 22.50 1 3-point 24.00 1219x610x254 1173x564 1181x572 610 C9483610 48.00 x 36.00 x 10.00 ANSI 61 Gray 14 14 CP4836 CP48366 46.20 x 34.20 46.50 x 34.50 1 3-point 24.00 1219 x 914 x 254 1173 x 869 1181 x 876 610 CSD48361OLG 48.00 x 36.00 x 10.00 RAL 7035 Lt.Gray 14 14 CP4836 CP4836G 46.20 x 34.20 46.50 x 34.50 1 3-point 24.00 1219x914x254 1173x869 11810876 610 CSD603610 60.00 x 36.00 x 10.00 ANSI 61 Gray 14 14 CP6036 CP6036G 58.20 x 34.20 58.50 x 34.50 1 3-point 30.00 1524 x 914 x 254 1478 x 869 1486 x 876 762 CSD60361 OLG 60.00 x 36.00 x 10.00 RAL 7035 Lt.Gray 14 14 CP6036 CP6036G 58.20 x 34.20 58.50 x 34.50 1 3-point 30.00 1524 x 914 x 254 1478 x 869 1486 x 876 762 CSD202012 20.00 x 20.00 x 12.00 ANSI 61 Gray 16 16 CP2020 CP2020G 18.20 x 18.20 18.50 x 18.50 1 Quarter-turn 10.00 508 x 508 x 305 462 x 462 470 x 470 254 CSD202012LG 20.00 x 20.00 x 12.00 RAL 7035 Lt.Gray 16 16 CP2020 CP2020G 18.20 0 18.20 18.50 x 18.50 1 Quarter-turn 10.00 508 x 508 x 305 462 x 462 470 x 470 254 CSD242012 24.00 x 20.00 x 12.00 ANSI 61 Gray 16 16 CP2420 CP2420G 22.20 x 18.20 22.50 x 18.50 1 Quarter-turn 12.00 610 x 508 x 305 564 x 462 572 x 470 305 CSD242012LG 24.00 x 20.00 x 12.00 RAL 7035 Lt.Gray 16 16 CP2420 CP2420G 22.20 x 18.20 22.50 x 18.50 1 Quarter-turn 12.00 610 0 508 0 305 564 x 462 572 x 470 305 CSD242412 24.00 x 24.00 x 12.00 ANSI 61 Gray 14 16 CP2424 CP2424G 22.20 x 22.20 22.50 x 22.50 2 Quarter-turn 5.00 610 x 610 x 305 564 x 564 572 x 572 127 CSD242412LG 24.00 x 24.00 x 12.00 RAL 7035 Lt.Gray 14 16 CP2424 CP24246 22.20 x 22.20 22.50 x 22.50 2 Quarter-turn 5.00 610 x 610 x 305 564 x 564 572 x 572 127 CSD302412 30.00 x 24.00 x 12.00 ANSI 61 Gray 14 16 CP3024 CP3024G 28.20 x 22.20 28.50 x 22.50 2 Quarter-turn 5.00 762 0 610 0 305 716 0 564 724 x 572 127 CSD302412LG 30.00 x 24.00 x 12.00 RAL 7035 Lt.Gray 14 16 CP3024 CP3024G 28.20 x 22.20 28.50 0 22.50 2 Quarter-turn 5.00 762 0 610 0 305 716 x 564 724 x 572 127 CSD303012 30.00 x 30.00 x 12.00 ANSI 61 Gray 14 14 CP3030 CP3030G 28.20 x 28.20 28.50 x 28.50 2 Quarter-turn 5.00 76207620305 7160716 724x724 127 CSD303012LG 30.00 x 30.00 x 12.00 RAL 7035 Lt.Gray 14 14 CP3030 CP3030G 28.20 x 28.20 28.50 x 28.50 2 Quarter-turn 5.00 76207620305 716x716 724x724 127 CSD362412 36.00 x 24.00 x 12.00 ANSI 61 Gray 14 16 CP3624 CP3624G 34.20 x 22.20 34.50 x 22.50 2 Quarter-turn 5.00 914 x 610 0 305 869 x 564 876 x 572 127 CSD362412LG 36.00 x 24.00 x 12.00 RAL 7035 Lt.Gray 14 16 CP3624 CP3624G 34.20 x 22.20 34.50 x 22.50 2 Quarter-turn 5.00 914 0 610 0 305 869 x 564 876 x 572 127 CSD363012 36.00 x 30.00 0 12.00 ANSI 61 Gray 14 14 CP3630 CP3630G 34.20 x 28.20 34.50 x 28.50 2 Quarter-turn 5.00 914 x 762 x 305 869 x 716 876 x 724 127 CSD363012LG 36.00 x 30.00 x 12.00 RAL 7035 Lt.Gray 14 14 CP3630 CP3630G 34.20 x 28.20 34.50 x 28.50 2 Quarter-turn 5.00 914 x 762 x 305 869 x 716 876 x 724 127 CSD363612 36.00 0 36.00 x 12.00 ANSI 61 Gray 14 14 CP3636 CP3636G 34.20 x 34.20 34.50 x 34.50 2 Quarter-turn 5.00 91409140305 869x869 876x876 127 CSD363612LG 36.00 x 36.00 x 12.00 RAL 7035 Lt.Gray 14 14 CP3636 CP3636G 34.20 x 34.20 34.50 x 34.50 2 Quarter-turn 5.00 914 x 914 x 305 869 x 869 876 x 876 127 CSD423612 42.00 x 36.00 x 12.00 ANSI 61 Gray 14 14 CP4236 CP4236G 40.20 x 34.20 40.50 x 34.50 1 3-point 21.00 1067 x 914 x 305 1021 x 869 1029 x 876 533 CSD423612LG 42.00 x 36.00 x 12.00 RAL 7035 Lt.Gray 14 14 CP4236 CP4236G 40.20 x 34.20 40.50 x 34.50 1 3-point 21.00 1067 x 914 x 305 1021 x 869 1029 x 876 533 CSD462412 48.00 x 24.00 x 12.00 ANSI 61 Gray 14 14 CP4824 CP4824G 46.20 0 22.20 46.50 x 22.50 1 3-point 24.00 1219x610 x305 1173x564 1181x572 610 CSD482412LG 48.00 x 24.00 x 12.00 RAL 7035 Lt.Gray 14 14 CP4824 CP4824G 46.20 x 22.20 46.50 x 22.50 1 3-point 24.00 121906100305 1173x564 1181 x572 610 CSD483612 48.00 x 36.00 x 12.00 ANSI 61 Gray 14 14 CP4836 CP4836G 46.20 x 34.20 46.50 x 34.50 1 3-point 24.00 1219 x914 x305 1173x869 1181 x876 610 CSD483612LG 48.00 x 36.00 x 12.00 RAL 7035 Lt.Gray 14 14 CP4836 CP4836G 46.20 x 34.20 46.50 x 34.50 1 3-point 24.00 12190914x305 1173x869 1181x876 610 CSD603612 60.00 x 36.00 x 12.00 ANSI 61 Gray 14 14 CP6036 CP6036G 58.20 x 34.20 58.50 x 34.50 1 3-point 30.00 1524 x 914 x 305 1478 x 869 1486 x 876 762 CSD603612LG 60.00 x 36.00 x 12.00 RAL 7035 Lt.Gray 14 14 CP6036 CP6036G 58.20 x 34.20 58.50 x 34.50 1 3-point 30.00 1524 x 914 x 305 1478 x 869 1486 x 876 762 CSD242416 24.00 x 24.00 x 16.00 ANSI 61 Gray 14 14 CP2424 CP2424G 22.20 x 22.20 22.50 x 22.50 2 Quarter-turn 5.00 610 x 610 x 406 564 x 564 572 x 572 127 CSD242416LG 24.00 x 24.00 x 16.00 RAL 7035 Lt.Gray 14 14 CP2424 CP2424G 22.20 x 22.20 22.50 x 22.50 2 Quarter-turn 5.00 610 x 610 x 406 564 x 564 572 x 572 127 EQUIPMENT PROTECTION SOLUTIONS PH 763.422.2211 •FAX 763.422.2600•HOFFMANONLINE.COM MILD STEEL 4 Spec-00286 H PENTAIR WALL-MOUNT ENCLOSURES CONCEPTTM WALL-MOUNT ENCLOSURES Conductive Panel Size Mounting CONCEPT DoE Gx11 J Catalog Number AxBxC in./mm Finish Door Ga. Body Ga. CONCEPT Panel Panel in.lmm in./mm Latches qty. Latches style in.lmm CSD363016 36.00 x 30.00 x 16.00 ANSI 61 Gray 14 14 CP3630 CP3630G 34.20 x 28.20 34.50 x 28.50 2 Quarter-turn 5.00 914 x 762 x 406 869 x 716 876 x 724 127 CSD363016LG 36.00 x 30.00 x 16.00 RAL 7035 Lt.Gray 14 14 CP3630 CP3630G 34.20 x 28.20 34.50 x 28.50 2 Quarter-turn 5.00 914x762x406 869x716 876x724 127 CSD483616 48.00 x 36.00 x 16.00 ANSI 61 Gray 14 14 CP4836 CP4836G 46.20 x 34.20 46.50 x 34.50 1 3-point 24.00 1219x914 x406 1173x869 1181x876 610 CSD483616LG 48.00 x 36.00 x 16.00 RAL 7035 Lt.Gray 14 14 CP4836 CP4836G 46.20 x 34.20 46.50 x 34.50 1 3-point 24.00 1219x914x406 1173x869 1181x876 610 CSD242420 24.00 x 24.00 x 20.00 ANSI 61 Gray 14 14 CP2424 CP2424G 22.20 x 22.20 22.50 x 22.50 2 Quarter-turn 5.00 610 x 610 x 508 564 x 564 572 x 572 127 CSD242420LG 24.00 x 24.00 x 20.00 RAL 7035 Lt.Gray 14 14 CP2424 CP2424G 22.20 x 22.20 22.50 x 22.50 2 Quarter-turn 5.00 610 x 610 x 508 564 x 564 572 x 572 127 CSD302420 30.00 x 24.00 x 20.00 ANSI 61 Gray 14 14 CP3024 CP3024G 28.20 x 22.20 28.50 x 22.50 2 Quarter-turn 5.00 762 x 610 x 508 716 x 564 724 x 572 127 CSD30242OLG 30.00 x 24.00 x 20.00 RAL 7035 Lt.Gray 14 14 CP3024 CP3024G 28.20 x 22.20 28.50 x 22.50 2 Quarter-turn 5.00 762 x 610 x 508 716 x 564 724 x 572 127 CSD363020 36.00 x 30.00 x 20.00 ANSI 61 Gray 14 14 CP3630 CP3630G 34.20 x 28.20 34.50 x 28.50 2 Quarter-turn 5.00 914 x 762 x 508 869 x 716 876 x 724 127 CSD36302OLG 36.00 x 30.00 x 20.00 RAL 7035 Lt.Gray 14 14 CP3630 CP3630G 34.20 x 28.20 34.50 x 28.50 2 Quarter-turn 5.00 914 x 762 x 508 869 x 716 876 x 724 127 Purchase panels separately. Optional NEMA-size panels require conversion kit Catalog Number CCPM4. B80 H 42 mm4 20 mm-'- C 19--I g PANEL BODY OPENING Y (ORDER ¢.50 SEPARATELY) 13 mm t 7 � " J .09 A-1.64 A-1.70 8 2 mm 75 -I 42 mm 43 mm TYP 4) 19 mm BODY DOOR ( OMIT OPENING SPACE CLEAR A - 2J x MIDDLE A (WHEN 2 e GGROUND ING t D STUDS IF _ 1 _726 I o 2.75 LATCHES li STUD G A<_30 70 mm ARE USED) �' 90 Illmm: 23 mm 38 mmi,,r Oe d 38 5mn III I M8X1.25 .52 mit 32 mm + 9 - COLLAR 13 mm 1.00 8-3.05 II 1 .t12 1.50 T� Y I STUD 90 52 25 mm 77 mm 38 � 75 OMIT DOOR CLEAR SPACE 29 mm X19 mm 23. mm 13 mm MIDDLE 1.45 1 .16 STUDS DOOR b 37 mn 29 mm IF B<31 02502-C BONDING 3.00 PROVISION SECTION Y-Y 76 mm (WITH PANEL INSTALLED) 5 MILD STEEL SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS Spec-00286 H