Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Haskins Goetz Residence WINDSOR FINAL WEST 3.21.18.pdf
Customer I* ARCHITECTURAL WINDOWS & DOORS Quote Short Form 0097 COUNTY ROAD 114 Totals Only QUOTE EXPIRES .... i GLENWOOD SPRINGS CO 81601 3/16/2019 'WINDSOR QUOTE DATE v.vaigr Millwork &DOORS Phone: 970-928-9314 Fax: 1-970-384-0023 Quote Not Ordered A Woodgrain Millwork Company BID BY Customer Information: Delivery Information: Greg Kontour Haskins Construction Company LLC Wayne Haskins Construction Company Inc. PRICE BOOK 360 Hilltop 1853 Lions Ridge Loop WEST Price Book 2018 P.O.Box 1913 CREATED Eagle Colo 81631 Vail Colo 81657 1/29/2018 Phone: (970)390-6383 Fax: Phone: (970)390-6383 Fax: gregk@awd.cc ** NOTE: Please see Quote Comments at the end of this report. PK#232 QUOTE# 1304702 STATUS CUSTOMER PO# DATE PRINTED None 3/21/2018 11:09 AM CUSTOMER JOB NAME TERMS QUOTE NAME PROJECT NAME 1853 Lions Ridge Loop WEST Alder Interior 1853 Lions Ridge Loop Wayne Haskins Construction Inc. Line# Room ID Quantity Overall RO Overall Frame 100 1-West Living 1 17 3/4"X 41 1/4" 17"X 40.75" II Pinnacle Clad Bronze Casement XXXX-1 Complete Unit LH Dual Low-E IG 6-11/16 Jamb Ext T,''- 1 f/ (Room ID: 1-West Living)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary) o$ s (Interior Stops:Contemporary)(FD: 17 x 40.75)(Natural Alder Int.Finish)(Black Spacer)(Preserve) (Tubes)(Bronze Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Bronze Screen-Not I * Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C)Performance Data:(U-Value:0.27) 17 (SHGC:0.2)(VT:0.45)(CR:43) *Units viewed from exterior. Line# Room ID Quantity Overall RO Overall Frame 200 2-West Living 1 17 3/4"X 41 1/4" 17"X 40.75" I I \ Pinnacle Clad Bronze Casement XXXX-1 Complete Unit RH Dual Low-E IG 6-11/16 Jamb Ext V^ (Room ID:2-West Living)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary) o$ /a (Interior Stops:Contemporary)(FD: 17 x 40.75)(Natural Alder Int.Finish)(Black Spacer)(Preserve) I / (Tubes)(Bronze Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C)Performance Data:(U-Value:0.27) j . (SHGC:0.2)(VT:0.45)(CR:43) *Units viewed from exterior. Windsor Windows and Doors Quote#: 1304702 Page 1 of 6 Line# Room ID Quantity Overall RO - Overall Frame IIM 300 3-West Entry 1 36 3/4"X 84 1/2" 36"X 84" II (Al)DAW 3214-(B1)WSET Rectangle-Standard Mulls 'i (AI)-Pinnacle Clad Bronze Awning 3214 Complete Unit V Dual Low-E IG 6-11/16 Jamb Ext(Room ID:3-West Entry)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary)(Interior Stops: Contemporary)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(Bronze p,II Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Bronze Screen-Not Applied) *Units viewed from exterior. (BetterVue)(Energy Star:Meets in NC,SC,S Zones)(R-PG40-AP)Performance Data:(U-Value:0.28) (SHGC:0.2)(VT:0.45)(CR:42) (B1)-Pinnacle Clad Bronze Direct Glaze Rectangle Complete Unit Dual Low-E IG 6-11/16 Jamb Ext (Room ID:3-West Entry)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Traditional)(FD: 36 x 66)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(No Brickmould) (Rigid Nail Fin)(Full Width Jamb)(Energy Star:Meets in NC, SC,S Zones)(R-PG70-FW) Performance Data:(U-Value: 0.28)(SHGC:0.23)(VT:0.54)(CR:45) Line# Room ID Quantity Overall RO I ! Overall Frame MR _ 400 4-West Stairs 1 63 3/4"X 113 1/4" 63"X 112.75" ,,I t. (Al)WSET Rectangle-(B1)DCS CustomCustom-(B2)DCS CustomCustom-(C1)WSET Rectangle-Standard Mulls �.. 31.1 ....,:.ti J (AI)-Pinnacle Clad Bronze Direct Glaze Rectangle Complete Unit Dual Low-E IG 6-11/16 Jamb Ext (Room ID:4-West Stairs)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Traditional)(FD:63 x ¢I• 36)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(No Brickmould) ‘0.617,= _ ( g Fin)(FullJamb)(Energy Zones)(CW-PG65-FW)Units viewed from exterior. (Rigid Nail Width Jamb Ener Star:Meets all US Zones CW-PG65-F Performance Data:(U-Value:0.27)(SHGC:0.23)(VT:0.54)(CR:41) (B1)-Pinnacle Clad Bronze Casement XXXX Complete Unit LH Dual Low-E IG 6-11/16 Jamb Ext (Room ID:4-West Stairs)(2605 Powder)(Setup(Standard))(Glass Stop Profile: Contemporary) (Interior Stops:Contemporary)(FD:31.5 x 40.75)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(Bronze Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb) (Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG30-C)Performance Data:(U-Value: 0.27)(SHGC:0.2)(VT:0.45)(CR:43) (B2)-Pinnacle Clad Bronze Casement XXXX Complete Unit RH Dual Low-E IG 6-11/16 Jamb Ext (Room ID:4-West Stairs)(2605 Powder)(Setup(Standard))(Glass Stop Profile: Contemporary) (Interior Stops:Contemporary)(FD:31.5 x 40.75)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(Bronze Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb) (Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG30-C)Performance Data:(U-Value: 0.27)(SHGC:0.2)(VT:0.45)(CR:43) (C1)-Pinnacle Clad Bronze Direct Glaze Rectangle Complete Unit Dual Low-E IG 6-11/16 Jamb Ext (Room ID:4-West Stairs)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Traditional)(FD:63 x 36)(Natural Alder Int.Finish)(Black Spacer)(Preserve)(Tubes)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Energy Star:Meets all US Zones)(CW-PG65-FW)Performance Data:(U-Value:0.27) (SHGC:0.23)(VT: 0.54)(CR:41) Windsor Windows and Doors Quote#: 1304702 Page 2 of 6 Line# Room ID Quantity Overall RO Overall Frame 500 5-West Bdrm.#1 1 57 1/4"X 48 1/2" 56.5"X 48" I // (Al)DCS CustomCustom-(A2)DCS CustomCustom-Standard Mulls 2 / (A1)-Pinnacle Clad Bronze Casement XXXX Complete Unit EL Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 5-West Bdrm.#1)(2605 Powder)(Setup(Standard))(Glass Stop Profile: Contemporary) 1 (Interior Stops:Contemporary)(FD:28.25 x 48)(Natural Alder Int.Finish)(Black Spacer)(Preserve) RO- 29 RO-29 � (Tubes)(Bronze Hardware)(Egress Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb) �� *Units viewed from exterior. (Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C)Performance Data:(U-Value: 0.27)(SHGC:0.2)(VT:0.45)(CR:43) (A2)-Pinnacle Clad Bronze Casement XXXX Complete Unit ER Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 5-West Bdrm.#1)(2605 Powder)(Setup(Standard))(Glass Stop Profile: Contemporary) (Interior Stops:Contemporary)(FD:28.25 x 48)(Natural Alder Int.Finish)(Black Spacer)(Preserve) (Tubes)(Bronze Hardware)(Egress Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb) (Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C)Performance Data:(U-Value: 0.27)(SHGC:0.2)(VT:0.45)(CR:43) Line# Room ID Quantity Overall RO Overall Frame 600 6-East Meditation 1 72 1/2"X 82 3/4" 71.75"X 82.25" Pinnacle Clad Bronze Direct Glaze Segment Top Picture Custom Size Complete Unit Dual Low-E IG 6-11/16 Jamb Ext(Room ID:6-East Meditation)(2605 Powder)(Setup(Standard))(Inside Stop Profile: Standard Stop)(FD: 71.75 x 82.25 x 74.25)(Direct Glaze)(Natural Alder Int.Finish)(Black Spacer) (Tempered Glass)(Preserve)(Tubes)(No Brickmould)(Drawing Number:040964.1A)(Energy Star: Meets all US Zones)(CW-PG50-FW)Performance Data:(U-Value:0.25)(SHGC:0.24)(VT:0.55)(CR: 41) „,5 *Units viewed from exterior. Line# Room ID Quantity Overall RO Overall Frame Wm 700 7-East Dining 1 72 1/2"X 48 1/2" 71.75"X 48" Pinnacle Clad Bronze Direct Glaze Rectangle Complete Unit Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 7-East Dining)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Traditional)(FD: 71.75 x 48)(Natural Alder Int.Finish)(Black Spacer)(Preserve)(Tubes)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Energy Star:Meets in NC,SC,S Zones)(CW-PG65-FW)Performance Data: 71E (U-Value: 0.29)(SHGC:0.24)(VT:0.53)(CR:44) RO 725 *Units viewed from exterior. Windsor Windows and Doors Quote#: 1304702 Page 3 of 6 Line# Room ID Quantity Overall RO Overall Frame 800 8-East Bdrm.#2 1 57 1/4"X 48 1/2" 56.5"X 48" I (Al)DCS CustomCustom-(A2)DCS CustomCustom-Standard Mulls (A1)-Pinnacle Clad Bronze Casement XXXX Complete Unit EL Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 8-East Bdrm.#2)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary) I 1 (Interior Stops:Contemporary)(FD:28.25 x 48)(Natural Alder Int.Finish)(Black Spacer)(Tempered RO--29 RO-29 Glass)(Preserve)(Tubes)(Bronze Hardware)(Egress Hardware)(No Brickmould)(Rigid Nail Fin)(Full �� � *Units viewed from exterior. Width Jamb)(Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C) Performance Data:(U-Value: 0.27)(SHGC:0.2)(VT:0.45)(CR:43) (A2)-Pinnacle Clad Bronze Casement XXXX Complete Unit ER Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 8-East Bdrm.#2)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary) (Interior Stops:Contemporary)(FD:28.25 x 48)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(Bronze Hardware)(Egress Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C) Performance Data:(U-Value: 0.27)(SHGC:0.2)(VT:0.45)(CR:43) Line# Room ID Quantity Overall RO ' Overall Frame 900 9-South Master 1 57 1/4"X 48 1/2" 56.5"X 48" It (Al)DCS CustomCustom-(A2)DCS CustomCustom-Standard Mulls 2N (A1)-Pinnacle Clad Bronze Casement XXXX Complete Unit EL Dual Low-E IG 6-11/16 Jamb Ext I /I (Room ID: 9-South Master)(2605 Powder)(Setup(Standard))(Glass Stop Profile: Contemporary) (Interior Stops:Contemporary)(FD:28.25 x 48)(Natural Alder Int.Finish)(Black Spacer)(Tempered 2625 T 20252025RO-O-29 RO-29 Glass)(Preserve)(Tubes)(Bronze Hardware)(Egress Hardware)(No Brickmould)(Rigid Nail Fin)(Full *Units viewed from exterior. Width Jamb)(Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C) Performance Data:(U-Value: 0.27)(SHGC:0.2)(VT:0.45)(CR:43) (A2)-Pinnacle Clad Bronze Casement XXXX Complete Unit ER Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 9-South Master)(2605 Powder)(Setup(Standard))(Glass Stop Profile: Contemporary) (Interior Stops:Contemporary)(FD:28.25 x 48)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(Bronze Hardware)(Egress Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C) Performance Data:(U-Value: 0.27)(SHGC:0.2)(VT:0.45)(CR:43) Line# Room ID J Quantity Overall RO Overall Frame 1000 10-South Master 1 57 1/4"X 48 1/2" 56.5"X 48" I (Al)DCS CustomCustom-(A2)DCS CustomCustom-Standard Mulls 2� � 1"/ (A1)-Pinnacle Clad Bronze Casement XXXX Complete Unit EL Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 10-South Master)(2605 Powder)(Setup(Standard))(Glass Stop Profile: Contemporary) (Interior Stops:Contemporary)(FD:28.25 x 48)(Natural Alder Int.Finish)(Black Spacer)(Tempered RO-29 RO-29 Glass)(Preserve)(Tubes)(Bronze Hardware)(Egress Hardware)(No Brickmould)(Rigid Nail Fin)(Full �� � *Units viewed from exterior. Width Jamb)(Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C) Performance Data:(U-Value: 0.27)(SHGC:0.2)(VT:0.45)(CR:43) (A2)-Pinnacle Clad Bronze Casement XXXX Complete Unit ER Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 10-South Master)(2605 Powder)(Setup(Standard))(Glass Stop Profile: Contemporary) (Interior Stops:Contemporary)(FD:28.25 x 48)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(Bronze Hardware)(Egress Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C) Performance Data:(U-Value: 0.27)(SHGC:0.2)(VT:0.45)(CR:43) Windsor Windows and Doors Quote#: 1304702 Page 4 of 6 Line# Room ID Quantity Overall RO Overall Frame 1100 11-North Stairs 1 24 3/4"X 41 1/4" 24"X 40.75" i ''''n Pinnacle Clad Bronze Casement XXXX-1 Complete Unit RH Dual Low-E IG 6-11/16 Jamb Ext r (Room ID: 11-North Stairs)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary) Vo V / (Interior Stops:Contemporary)(FD:24 x 40.75)(Natural Alder Int.Finish)(Black Spacer)(Tempered // Glass)(Preserve)(Tubes)(Bronze Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb) I (Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C)Performance 24 -i Data:(U-Value:0.27)(SHGC:0.2)(VT:0.45)(CR:43) - RD-24.75 -, *Units viewed from exterior. Line# Room ID Quantity Overall RO - ' Overall Frame 1200 Door#2-North Ding. 1 67 1/4"X 82 1/2" 66.5"X 82" 1 Pinnacle Clad Bronze Two Panel French Style XXXX Complete Unit OX Dual Low-E IG 6-11/16 Jamb Ext(Room ID:Door#2-North Ding.)(2605 Powder)(Setup(Standard))(Glass Stop Profile: 2 a Contemporary)(FD: 66.5 x 82)(Natural Alder Int.Finish)(Bronze Sill)(Black Spacer)(Tempered Glass) 1 (Preserve)(Tubes)(Sliding Contemporary Faux Bronze Standard Handle Set)(Bronze Footbolt)(No Brickmould)(Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US 6S Zones)(R-PG40-SD)Performance Data:(U-Value:0.29)(SHGC:0.17)(VT:0.38)(CR:44) RO-5725 *Units viewed from exterior. Line# Room ID 1 Quantity Overall RO Overall Frame 1300 12-North Bdrm.#2 1 29 1/8"X 48 1/4" 28.375"X 47.75" 1 I Pinnacle Clad Bronze Casement XXXX-1 Complete Unit RH Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 12-North Bdrm.#2)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary) o� (Interior Stops:Contemporary)(FD:28.375 x 47.75)(Natural Alder Int.Finish)(Black Spacer) (Tempered Glass)(Preserve)(Tubes)(Bronze Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width I1 I Jamb)(Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C) - 25.375 - Performance Data:(U-Value: 0.27)(SHGC: 0.2)(VT:0.45)(CR:43) •- RD-29.125 -. *Units viewed from exterior. Line# Room ID Quantity Overall RO Overall Frame . I 1400 14-North Meditation 1 30 3/4"X 41 1/4" 30"X 40.75" 11 `~` Pinnacle Clad Bronze Casement XXXX-1 Complete Unit RH Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 14-North Meditation)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary) o� (Interior Stops:Contemporary)(FD: 30 x 40.75)(Natural Alder Int.Finish)(Black Spacer)(Preserve) 1 , '' (Tubes)(Bronze Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Bronze Screen-Not 1 .7 I Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C)Performance Data:(U-Value:0.27) RO 30.75 (SHGC:0.2)(VT:0.45)(CR:43) *Units viewed from exterior. Line Item Comments:WINDOW DOES NOT MEET EGRESS Line# Room ID Quantity Overall RO Overall Frame 1500 13-North Bdrm.#1 1 29 1/8"X 48 1/2" 28.375"X 48" 11 Pinnacle Clad Bronze Casement XXXX-1 Complete Unit EL Dual Low-E IG 6-11/16 Jamb Ext (Room ID: 13-North Bdrm.#1)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary) oi (Interior Stops:Contemporary)(FD:28.375 x 48)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(Bronze Hardware)(Egress Hardware)(No Brickmould)(Rigid Nail Fin)(Full 11 ' .., Width Jamb)(Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C) - 25.375 Performance Data:(U-Value:0.27)(SHGC: 0.2)(VT:0.45)(CR:43) - RD-29.125 -, *Units viewed from exterior. Windsor Windows and Doors Quote#: 1304702 Page 5 of 6 Line# Room ID Quantity Overall RO Overall Frame 1600 Garage 1 101"X 33 3/4" 100.25"X 33.25" (Al)DCS CustomCustom-(A2)DCS CustomCustom-(A3)DCS CustomCustom-(A4)DCS CustomCustom-Standard Mulls '— 111 f''I''f (A1)-Pinnacle Clad Bronze Casement XXXX Complete Unit LH Dual Low-E IG 6-11/16 Jamb Ext (Room ID:Garage)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary)(Interior Stops:Contemporary)(FD:25.0625 x 33.25)(Natural Alder Int.Finish)(Black Spacer)(Tempered *Units viewed from exterior. Glass)(Preserve)(Tubes)(Bronze Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb) (Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C)Performance Data:(U-Value:0.27)(SHGC:0.2)(VT:0.45)(CR:43) (A2)-Pinnacle Clad Bronze Casement XXXX Complete Unit S Dual Low-E IG 6-11/16 Jamb Ext (Room ID:Garage)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary)(Interior Stops:Contemporary)(FD:25.0625 x 33.25)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Energy Star:Meets all US Zones)(CW-PG40-FW)Performance Data:(U-Value:0.26)(SHGC:0.22)(VT:0.51)(CR:43) (A3)-Pinnacle Clad Bronze Casement XXXX Complete Unit S Dual Low-E IG 6-11/16 Jamb Ext (Room ID:Garage)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary)(Interior Stops:Contemporary)(FD:25.0625 x 33.25)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb)(Energy Star:Meets all US Zones)(CW-PG40-FW)Performance Data:(U-Value:0.26)(SHGC:0.22)(VT:0.51)(CR:43) (A4)-Pinnacle Clad Bronze Casement XXXX Complete Unit RH Dual Low-E IG 6-11/16 Jamb Ext (Room ID:Garage)(2605 Powder)(Setup(Standard))(Glass Stop Profile:Contemporary)(Interior Stops:Contemporary)(FD:25.0625 x 33.25)(Natural Alder Int.Finish)(Black Spacer)(Tempered Glass)(Preserve)(Tubes)(Bronze Hardware)(No Brickmould)(Rigid Nail Fin)(Full Width Jamb) (Bronze Screen-Not Applied)(BetterVue)(Energy Star:Meets all US Zones)(R-PG40-C)Performance Data:(U-Value:0.27)(SHGC:0.2)(VT:0.45)(CR:43) Quote Comments: Please send(2)EXTRA Right Hand Cranks&Covers,(2)Left Hand Cranks&Covers,(1)Left&(1)Right completeTruth crank mechanism for Line Item 500 for owner to have on hand for repairs. Disclaimer: SUB-TOTAL: $23,774.09 LABOR: $0.00 FREIGHT: $0.00 SALES TAX: $689.44 TOTAL: $24,463.53 Messages: *Units meeting Egress size conform to 2015 IRC Section R310.2 Egress requirements;Local codes may differ. Customer is responsible to confirm units meet all applicable requirements. Submitted By: Date: Accepted By: Date: We appreciate the opportunity to provide you with this quote! Windsor Windows and Doors Quote#: 1304702 Page 6 of 6